Inline power module timeout?

I have a 6513 with WS-X6148-45AF linecards supplying power to Cisco VoIP phones.
yesterday, one of the blades experienced an error that was reflected in the logs as
...inline power module timout (25)
All the phones on the blade went down (rebooted)
Anyone know what this error is all about?

Hi,
This could be due to the following:
https://tools.cisco.com/bugsearch/bug/CSCed87264/?reffering_site=dumpcr
Hope this helps. Remember to rate any useful posts.

Similar Messages

  • Inline power for Cisco 4506

    Hello all,
    I recently added POE series RJ45 blade to one of my 4506's in order to power some new Cisco WAP's.  The modules are functioning nominally with exception to not getting inline power to any devices.  Here's the skinny:
    Here’s a snapshot of the inline power issue:
    CORE-WH-4506#sh power detail
    Power                                             Fan      Inline
    Supply  Model No          Type       Status       Sensor   Status
    PS1     PWR-C45-1400AC    AC 1400W   good         good     n.a.
    PS2     PWR-C45-1400AC    AC 1400W   good         good     n.a.
    Power supplies needed by system    : 1
    Power supplies currently available : 2
    Power Summary                      Maximum
     (in Watts)              Used     Available
    System Power (12V)        710        1360
    Inline Power (-50V)         0           0
    Backplane Power (3.3V)      0          40
    Total                     710        1400
                                 Watts Used of System Power(12V)
    Mod   Model                 budgeted instantaneous  peak   out of reset  in rese                          t
     1    WS-X45-SUP6-E            260         --        --        260         260
     2    WS-X4448-GB-RJ45         120         --        --        120          72
     3    WS-X4648-RJ45V+E          92         --        --         92          10
     4    WS-X4448-GB-SFP           65         --        --         65          50
     5    WS-X4248-FE-SFP           53         --        --         53          20
     --   Fan Tray                 120         --        --        --          --
           Total                   710         --        --        590         412
                            Watts used of Chassis Inline Power (-50V)
                            Inline Power Admin  Inline Power Oper
    Mod   Model                PS     Device       PS     Device     Efficiency
     1    WS-X45-SUP6-E            -        -          -        -           -
     2    WS-X4448-GB-RJ45         -        -          -        -           -
     3    WS-X4648-RJ45V+E         -        -          -        -           -
     4    WS-X4448-GB-SFP          -        -          -        -           -
     5    WS-X4248-FE-SFP          -        -          -        -           -
           Total                   0        0          0        0
    Here’s a kick-out from trying to force the interface inline power:
    *Dec  9 07:23:36.519: %ILPOWER-5-ILPOWER_POWER_DENY: Interface Gi3/47: inline power denied. Reason: Insufficient inline power, requested(32258) available(0).
    What am I missing?

    Yes.  Makes sense.  You need to upgrade your 1400w Power Supply to something bigger.  Here's the math: 
    Total 710 -- -- 590 412
    You've got a 4506 chassis and populated six out of seven slots.  With six slot loaded, the line cards pull up to 710w from your Power Supply.   Now if you look at the Data Sheet for the WS-X4648-RJ45V+E line card it states that this particular line card can support up to 48 ports running 15.4w (or 24 ports at 30w PoE).  The product of 30w & 24 ports is 720.  So if you add up 720 and 710 you get a sum of 1430 which is OVER your 1400w Power Supply.  This is the reason why the line card is complaining.
    It doesn't matter if you've got a WS-X4648-RJ45V+E line card and you're going to, for example, plug 10 APs.  When the line card is loaded into the chassis, the line card will immediately "chop" or "slice" 720w off the power supply.  This is how it works.

  • X200 black screen and beep sound when power module is plugged on and off

    Hello,
    I have the following problem. Today I turned on my X200 without power module, and when I plugged in power - the screen starts to flicker. This was not before, and I am using my laptop only during a week.
    After that I turned on the laptop with power module, it was OK, but when I plug out and plug in power module, computer makes "beep" sound and becomes black for a second. Is that normal behavior? 
    Thank you!

    does your battery hold a full charge. is it in good shape.  is your machine under warranty. you could try support, but they're probably just gonna tell you to open a service claim.  another thing, did it always do this or is this something that just started. did you just download any updates and this started right after. or did it just start doing this for no reason.
    T430u, x301, x200T, x61T, x61, x32, x41T, x40, U160, ThinkPad Tablet 1838-22R, Z500 touch, Yoga Tab 2 Windows 8.1, Yoga Tablet 3 Pro
    Did someone help you today? Press the star on the left to thank them with a Kudo!
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"!
    If someone helped you today, pay it forward. Help Someone Else!
    English Community   Deutsche Community   Comunidad en Español   Русскоязычное Сообщество

  • Using DC supply to power module

    I am planning to change my power infra into a all DC to get rid of clumsy UPS system. Other goals are simplifying the power infra, having true no-break system and increase energy efficiency
    Is it possible to run, say Catalyst 6500, with 220V DC input?
    I know that all power modules are made with SMPS architecture and can run on both DC & AC power supply but zero-crossing detectors, if installed, inside power supply module is making the trouble.

    The key to erasing media with a magnet is relative motion. Either the magnet (or it's field) must be moving or hte media must be moving. With a Hrd Drive (wheter it is in an iPod, a laptop or a desktop is spinning. If you place a permenant magnet next to it ther eis relative motion and you can get erasure. If the drive is powered off, this is much harder to do.
    The drives themselves (and magnetic tape erasers) use fluctuating magnetic fields to do the easing.
    The shuffle is 'solid state'; it has no moving parts. It would be very, very hard to erase it with any magnetic field, especially one from the power connector which is not fluctuating. Put one or 2 unneeded files on the shuffle and test it. Hold it near that magnet or a stronger one and see if the files are damaged. I expect they will survive.
    What has happened to me (and I expect has happened in this case) is that you did not wait for the Mac (or the PC) to finish writing to the drive before removing it. When I get in a hurry I usually end up reformatting mine. The drive must be ejected from both computers (on the pc this can take 2 steps) and you must wait for the lights to go out before removing it.

  • Deskjet 9800 power module

    I have spent nearly six weeks attempting to find a replacement for the power module. First off, I assume that getting no reading what so ever on a multimeter that my module is bad. The part number does not match any part number by HP. The unit was manufactured in January, 2007. The part number agreed upon was C8165-67062. As this is an enclosed case power module that is attached to the printer there is no way to test a $.50 diode or some other cheap part that may have gone bad without removing the casing. I contacted IMPACT, as suggested by chat personnel, and they quoted a price of 30.00. Another support person contacted me by email and said that the part is no longer made and I should send the part in to be repaired. I ordered the in stock part from IMPACT, which suddenly became unavailable and had to be ordered from HP at 90.00. The entire support thing had been elevated to some higher-ups, where it was suddenly kicked over to business support and no contact from them in over a week, (reported to contact me within 24 - 48 hours). At the elevated contact, the support person agreed with me that HP should have the part as the printer is not that old. None of the suggested contacts I tried had the item. Has anyone had any success in opening the sealed power module and testing the parts? I do not wish to spend  1/3 - 1/2 the cost of a replacement printer on a power module that may burn out again, nor the same amount or more on "bench time" for a 50 cent part when other more reliable printers are available from outside of HP. I have read the environmental impact statement that HP has published and can't help but wonder how truthful it is. It puts the environmental impact directly on the shoulders of the consumer. Much the same way support has worked out. As the sale season is in full swing and of limited amount of time, I would greatly appreciate any help anyone could offer. Just please don't tell me to contact anyone at HP. I can not do another complete circle of dead ends.

    I have since sent letters and emails to several different organizations. That this module is incongruous with HP's environmental policy statement is an understatement. HP does offer to recycle it for free, or I can donate it, or attempt to circumnavigate the order process and purchase the part at a minimum of 40% higher cost from HP's partners, or go third party or auctions. Again, this printer was manufactured less than three years ago. A little young for parts to be put out to pasture don't you think? Apparently, I am not the only person who thinks so. Consumers Affairs will be publishing my letter(s) of complaint. I will soon begin my campaign of exposing the real HP environmental practices as opposed to their statement.

  • Can I replace the power module in my iMac G4 17" Flat Screen computer?

    My iMac G4 17" Flat Screen will no longer power up. It has been getting slower and slower the longer it was running until finally I have no power at all.
    Can I replace the power module, where do I get one, how much do they cost and how big a job is it to swap it out?
    Any help, or information that you can give me will be greatly appreciated.

    Can I replace the power module, where do I get one, how much do they cost and how big a job is it to swap it out?
    To repair your iMac G4 17" Model you can go to iFixit

  • Is there a bug related to inline power of 3550?

    Hi:
    We are using the inline-power function of some WS-C3550-24PWR-EMI to power on some aironet 1230 APs. There are less than 5 APs on one 3550 usually.
    For unknown reason, those 3550s keep shutting down those FE interfaces connected by APs. We can do 'no shut' under the interface to re-enable the AP, however those interfaces will be shut down again after several days. We only see this problem on 3550 so far. Can anybody fell free to tell me what the reason is and how to fix it?
    Sincerely,
    cafershop1

    Hi:
    We are only using b/g. I checked the power level on a 3550 withou this problem, most of APs are using 4.4v.
    Those switchs are running for a long time, I think around 2 or 3 years.
    On the software side, we just enable inline power by the command of 'power inline auto' on the 3550. The IOS version for APs are 12.3(8)JA2 and switch are 12.1(22)EA8.
    On the hardware side, all APs are plug into network jack on the wall and then connect to switches. The distances between APs to switches usually are less than 100 feet.
    Sincerely,
    cafershop1

  • Cisco 6921 - Inline Power Capable?

    I am trying to determine if Cisco 6921 phones are actually compatible with Inline Power (Cisco pre-standard). 
    I have seen multiple data sheets from Cisco that say that they are, and then others that say that they only support 802.3af.  They are 6.3w phones, so I'd assume they support pre-standard, but I am not 100% sure without having one in front of me.  Does anybody know?
    Thanks!

    Wrong forum, should be "IP Telephony". You can move the posts using the control panel on the right".
    Anwyay, that may also depend by the specific switch you have. Check:
    https://supportforums.cisco.com/message/3581321

  • Voip inline power options and qos

    hi all
    can you please tell me how I set the inline power on my switches to off and auto, also how and where do i set the qos for my voip phones !!

    To modify the power settings use the following interface commands:
    power inline auto |never |static
    auto Automatically detect and power inline devices
    never Never apply inline power
    static High priority inline power interface
    bye
    FCS
    Please rate me if I helped.

  • ILP:: Inline power process coredump for switch

    Hi all,
    I am investigating POE issues on a 3850 stack, and i notice some things while troubleshooting
    Switch Ports Model              SW Version        SW Image              Mode   
         1 56    WS-C3850-48P       03.03.03SE        cat3k_caa-universalk9 INSTALL
    *    2 56    WS-C3850-48P       03.03.03SE        cat3k_caa-universalk9 INSTALL
    I have some debugging active.
    ILPOWER:
      ILPOWER event debugging is on
      ILPOWER controller debugging is on
    I see in the logs the following message
    021030: Nov 14 2014 11:05:01.185 CET: ILP:: Inline power process coredump for switch 2
    021034: Nov 14 2014 11:05:06.841 CET: ILP:: Inline power process coredump for switch 1
    021041: Nov 14 2014 11:05:11.188 CET: ILP:: Inline power process coredump for switch 2
    021048: Nov 14 2014 11:05:16.872 CET: ILP:: Inline power process coredump for switch 1
    021049: Nov 14 2014 11:05:21.198 CET: ILP:: Inline power process coredump for switch 2
    021065: Nov 14 2014 11:05:27.002 CET: ILP:: Inline power process coredump for switch 1
    021079: Nov 14 2014 11:05:31.209 CET: ILP:: Inline power process coredump for switch 2
    021080: Nov 14 2014 11:05:36.873 CET: ILP:: Inline power process coredump for switch 1
    021093: Nov 14 2014 11:05:41.219 CET: ILP:: Inline power process coredump for switch 2
    It seems its a proces as each of the stackmember logs this message every 10seconds.
    I have  search-engined this message, but to no avail,
    i dont think this is a software crash as i dont have any crashfiles on the system.
    What process generates these messages and why, how to troubleshoot this.
    thank you in advance.
    With kind regards,
    Thijn van der Schoot.

    What output do you get from:
    #sh power inline

  • Inline power controller post fail

    After a huge lightning, I woke up and find one of my Cisco 2960 switch with all Ethernet ports green but when I connect using console, I found the following message:
    inline power post fail.
    What normally caused this and how can I resolve it?

    Get the appliance RMA-ed. 

  • Inline power support

    Hi,
    Does the new ESW switches support "Cisco Inline Power" Some Service Providers are using CP-7940/60 with SIP image as a service and need switches that automatically detects that the device only support Inline Power..
    regards
    /Bjorn

    The ESW 500 series of switches does power up the 7960 / 7940 phones (pre standard) via POE.

  • Poe881 Router and Cisco Inline Power (pre-standard PoE)

    I have a number of 881 Routers and 79x0 IP Phones. These phones use "Cisco Inline Power", aka "pre-standard PoE". In other words, they are not compatible with standard 802.3af PoE.
    It would be possible for me to install a daughtercard and DC adapter in the 881 routers and provide PoE to two of the ethernet ports. My question is whether the 881 (when equipped for PoE) will support Cisco Inline Power, or if it will only support 802.3af.
    For reference, the 200 and 300 series Small Business switches support these phones with a software upgrade. See this link: https://supportforums.cisco.com/document/71841/200-and-300-switches-now-supports-cisco-pre-standard-poe-legacy-poe
    Many thanks,
    Tom

    My question is whether the 881 (when equipped for PoE) will support Cisco Inline Power, or if it will only support 802.3af.
    Hi Tom,
    I don't have an 880 but I have a large fleet of 890 and all of them have PoE and I know these 890 support 802.3af easily.

  • Need to find the weight and dimensions of RSP and Power Module of ASR 9922

    Need to find the weight and dimensions of RSP and Power Module of ASR 9922. I am unable to find the same in the data sheet. Please help
    Regards
    Thanveer
    "Everybody is genius. But if you judge a fish by its ability to climb a tree, it will live its whole life believing that it is a stupid."       

    duplicate post
    https://supportforums.cisco.com/message/4143520#4143520
    Riv

  • Officejet 4500 power module blinking . cant power on

    panel blinks also.printer wont power on. just unpacked printer. ready to return .any suggestions?

    fformica01,
    Lets try resetting the power module. Remove the module from power and printer for 30 seconds. After the 30 seconds plug the power module into a wall outlet directly. Power strips can cause some problems occasionally when there is a voltage or amperage drop across the strip. If the reset and wall outlet trick does not work the printer likely requires servicing. Let us know if it helps.
    Best of Luck!
    You can say thanks by clicking the Kudos Star in my post. If my post resolves your problem, please mark it as Accepted Solution so others can benefit too.

Maybe you are looking for

  • What adapter do i need to connect my computer to the internet

    I am woundering what adapter i need to plug into my computer so that i can  plug my computer directly into the wall and use the internet using a ethernet cord.  I am not wanting to use wify for that does work great. I have to plug my computer directl

  • New Computer Difficulty With Itunes

    I just got a new computer, and went to download the latest version of itunes. I'm not the greatest with this stuff but it won't let me run the setup for itunes saying that there isn't a legitimate digital signature? Do i need to disable my antivirus

  • Problems exporting GB2 songs to iTunes/equalizing volume

    I'm posting this in both GB and iTunes becuase I don't know where the problems lies. 1) I've exported five tunes I created in GB2. a) Average length of song is about 3 minutes; b) Volume settings were pretty much the same. I deliberately set them as

  • How do I get youtube videos to play

    Hi I'm unable to play youtube videos on my phone. I get the message 'an error has occurred' I'm on the giffgaff network and its been suggested that it's because they can't send the service book for youtube. Is there a way around this please without m

  • Downloading files contained in a configuration

    I have created a configuration with many files. I can't seem to figure out how to download all the files contained in the configuration. For example: In the RON, expand the configurations node, select MyConfiguration, right-click... no download files