Inprocess Inspection & result recording
Hi all,
We are implementing QM.
The requirement of client is to carry out inprocess inspection(preferable without inspection plan) including result recording & defect recording & that to with quiet ease.
Help me with the basic settings.
Also to have the relevant report to analyse the inspection activities.
We are using developed T code for operation confirmation, in the back end it is co11n only. So also elaborate the consequences of the same if any.
Mangesh
Ramanuj/ Murali,
Thanks for your reply.
Let me explain the process in details.
We are having around 10 operations.
We need to carry out inprocess inspection for 8 operation starting from 3rd operation.
The inspection to be carried out is like length- 5 cms, shape- ok or not ok, if not ok then what is the defect, assay- 90%, if below 90% then defective like this.
I have assigned inspection type 03 in QM view in the material master.
Inspection lot is also getting created.
I am stuck up at result recording & defect recording.
So kindly guide me how to map this in details.
Efforts would be appreciated.
SmanS
Similar Messages
-
FM for Quality Inspection Results Recording.
Hello!
I was wondering if someone can help me out on this one:
The requirement calls for entering the same set of results for several inspection lots. Short of using batch input, is there a function module that can enter the results of an inspection lot?
Thanks in advance. Points for anyone who can give helpful answers...Hi Vidhya,
Can you please elucidate the isuue a bit more in detail........ in which tab during result recording you are trying to attach file......So I can help with what ever little I know in SAP...........
Regards
Kaushik -
Need custome program for qe51n (inspection result recording)
Hi Gurus,
I am getting the same error from the BAPI BAPI_INSPOPER_RECORDRESULTS. Defects occured during confirmatio you find any solution? If yes please share me the solution and sample code give some ssample code .
Javed
Edited by: Javed Parvez on Jun 8, 2009 2:58 PMDear Neeraj
one suggestion would be create an qualitative MIC and give the short text " Inspection according to Drawing specification". Create a characteristic code as 1) Ok 2) Not ok. So while result recording you select ok or not ok according to the result and in Inspection Decription you can insert your comments
Regards
gajesh -
Table to see Inspection result recording
Mentors
We have material where in there are intermittenat 60 operations to be recorded based on 3 stages of the meterial .All the operations have single characteristic value .Results are recored for the lots whcih are created based on the stage
1) For stage new arrival result recodering is done for 10-25 operations
2) Dispute stage result recodering is done for 31-46 operations
3) Recycle stage result recodering is done for 50-66 operations
now i want to know How to check in which of the operation , results are recorded in table ? ( Table sequence to derive values stored for the results for the operations )Hi,
Check in the following tables.
QAES : Sample unit table
QASR : Sample results for inspection characteristic
QAMV : Characteristic specifications for inspectic
QAPP : Inspection point.
Regards
Ravi Shankar. -
Quality inspection result recording thru LSMW
Dear All,
I donot have any idea of LSMW.
We have requirement of upload result data which are maintained in EXCEL.
I gone thru document of LSMW available on NET.
Can any one guide me step-by-step procedure for the same or can share good document.
Thanks in advance,
NiravHi,
Pl go through the below documents.
[LSMW|https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0Bw3TmL29DWuPNzQ5OTU1ZTYtNTllMC00OTE1LWE5YWMtYTBlYWUxMTk5Nzgz&hl=en&authkey=CNDa2_0G]
Arun -
Results recording tab not appearing in QA32
hi,
can anyone tell me why results tab not appearing in QA32 , is there any authorisation missing?Just check which roles are added to that used id
selec 1 role that is relevent to inspection (result recording) and add QE01 t_code in that role.
take help from ur basis guy for this. -
Result recording inprocess inspection for production order!
Hi,
I have a scenario in for prod order in process inspection.
I have an operation to machine the shaft for 3 hrs. And every hour I need to take an reading and note down in the inspection. For the same reason I created master data of MIC Quantitative, Sampling procedure with sample size 1
On routing for the same material, Usage 1 and status 4 Released for general, Inspection point 200 and sapmle drawing procedure with fixed qty 3.
Generated a prod order and released, got inspection lot for lot origin 03. But when I try to enter 3 different readings per hour could not able to achieve this.
Kindly help me out.
Regards,
N. NagarajuAre u using physical samples? If not, I wouldn't use the sample drawing procedure.
Set your characteristic to individual results recording in your control indicators. Set the sampling procedure to be a fixed sample size of three.
You should be able enter three results then for the characteristic.
FF -
Result Recording for inprocess lot
Hello SAP gurus.
For in process inspection lot i have 3 operation for testing my requirment is if i goning for result recording for second operation without result recording for first operation system should restrict me. we are using 100 inspection point for inprocess inspection please suggest how can we do this?
Regards.Dear,
Goto OPK4 -Select order type /Plant - Select 'Generally valid setting' for 'Operation sequence-Select 'Error when operation sequnce is not adhered and also QM Error message if no inspection result exists.
Or you can use the exit CONFPP05 PP order conf.: Customer specific enhancements when saving .
Regards,
R.Brahmankar -
Result recording for quantitative inspection characteristic
Team
Greetings!
Please find the following requirement.
We are using quantitative characteristics inspection.
Inspection lots are created automatically and the sample size for each characteristics are determined based on the sampling proceedure.
when we do result recording for a characteristic, say the sample size is 5, even if any one of the sample does not fall under the limit, we need the characteristic to be rejected.
How can this be addressed.
Gobinathan G.
-
Requirement of displaying inspection method in result recording
Dear All,
My clients requirement is to have the inspection method code in the result recording screen. I have the option of inspection method short text in the result recording screen. But i want a code should appear so that user can see the same for his convinient reference.
Regards,
AnilDear Anil,
You can create attachment in word of whatever data you want to maintain for inspection method. you can also save drawings in this attachment. assign this attachment to inspection method .You can assign attachment by
Service for Object=> Create=>Create Attachment
Now this attachment u can view while doing result recording & parallaly u can record results. Hope this will help you.
Regards
Amit -
Result recorded values not appearing in printing the Inspection lot
Hi all ,
Using QC21 i am printing the Inspection lot but the Result recorded values are not appearing in printing the Inspection lot .
while creating the certifacte profile i had maintained the MIC for which i had saved as Summary for recording . if i change this to Orginal value it says that this doesnt exist in the Inspection plan .
can somebody help me on this .
thanks ,
ksrHi
1.Make sure that you are using same MIC in Task list & certificate.
2.make sure that you have done RR & taken UD.
3.make sure that MIC is reference MIC.
4.Make sure that profile is attached to material
Regards
Sujit -
Runtime error for Inspection Point Results Recording
Hi,
I am changing the already done Results Recording for using already used Inspection Point.
I am getting the runtime error. Anybody came across such error?
Regards
RamakanthHi,
In the in-process inspection I am using Inspection Points. Initially I have done Results Recording once with quantities.
And then again I wanted to change the quantities for the same Inspection Point. So, I went to Results Recording for same Inspection Point and changed the quantities and saving. At this event I am getting Runtime error.
I have even deactivated one BADI INSPECTIONLOT_UPDATE and tried again. Even then I am getting same error.
Ultimately my requirement is this:
My client wants UD at operation level. They want only quantity which is accepted in Results Recording to be moved to the next operation. In the operation level confirmation the system should only accept the quantity which is accepted in Results Recording.
Any suggestion in this regard.
Thanks
Ramakanth -
Result recording to be done after UD with long term inspection
Dear All
I have activated two MIC's for long term inspection. Inspection lot is created and UD is provided after Result recording. i have run QA12 and go to EDIT/RESET/INSPECTION COMPLETION. status of UD changed to LTIN and then in Qe51 / qe51n i selected long term inspection but error message is coming '' NO CHARACTERISTICS WERE FOUND". Plz help , how to do result recording after UD.Dear Even if the char is long terms & if you have forcefully completed the chars then even if char has LTIN status it will not allow you.
But check this in your sandbox and revert.
1. In the MIC set the 'Optional Characteristic' and 'Long tem inspection ' in the control indiactors.
2. Attach MIC in inspection Plan
3. Do results recording and comlpete UD. all short term charactericts are closed.
4. QA12Change UD with history for Inspection Lot ,
Menu-> Reset inspection completion -> Status changes to LTIN
5. Goto QA02 --> you woudl see " do you wnat to compete Long term inspections" --> yes
6. Then Long term inspection characterictic is open for results recording.
7. Change and complete results --> Make UD
Check and Revert.
Cheers
KK -
Result Recording for In Process Inspection
At the time of taking Usage Decision for In Process Inspection, system gives warning message if Results have not been recorded. Can this Warning message be changed to Error message so that user could not able to take UD without recording the results.
Thanks in advance
SriniDear Srini
1)Use status profile for restricting the user to do UD without doing RR. use this link for doing it
Link: [https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/20fbc091-ea3a-2b10-f0a3-877ffbf36436]
2) you can use this auth object for doing the same restriction - Q_INSP_FIN
Link: [Re: Preventing UD without results recording]
Regards
Gajesh -
In-process inspection- operation wise result recording sequence
Hello Everyone,
I have just come across a requirement and would be grateful if someone can help me out in this regard.
1. This is make to stock discrete manufacturing scenario.
2. Inspection type 03 has been activated in material master.
3. The setting in OPK4 are, error if no inspection results exist and error when operation sequence is not adhered to.
4. As a result of which I cannot confirm the operation in CO11N unless result recording is done for corresponding operation.
The requirement,
1. User should not be able to carry out result recording for operation 30 unless at least 1 quantity of operation 20 (preceding operation) is confirmed. Likewise it should behave for rest of the operations.
2. Practically material is processed for operation 30 only if 20 is confirmed. Therefore operation 30 should be inspected after 20. System allows to input result recording for all the operations irrespective its confirmations.
Is there any standard solution for this or should I go for any exit?
Thank you,
Anand RaoHi Sujit,
Thanks for so prompt response.
I am using inspection point 100. Still it is not restricting. The operation confirmation is done through CO11N and not feasible for users to perform it through QM module.
The logic is, if I try to carry out result recording for operation 30 , system should firstly check whether any confirmation number exists or (at least 1 quantity is confirmed)for previous operation i.e. 20. If not it must stop doing RR for 30 operation.
Whether exits QEEM0011 and QEEM0015 can restrict this, as by their description I think these work after entering RR. Here it is required before RR. Any guesses?
Thank you again for your kind reply.
Regards,
Anand
An addition,
Even though QEEM0011 works before valuation user is able to enter RR. The requirement is user should not enter the any RR irrespecive of valuation. If user enters RR and do not valuate it this exit may not work and eventually can allow to confirm OP30.
Edited by: Anand Rao on Aug 24, 2011 1:21 PM
Maybe you are looking for
-
Downloaded latest itunes, cant download 5.0.1 due to error 3194 help!
I have downloaded the latest version of itunes, and i still can't update my iphone 4 to 5.0.1 due to error 3194 error. Please help
-
Trying to measure voltage through SCXI-1127/1331 2-wire connection [ Edited ]
Hai , this is madhava from LSU,I am working on ERT with NI hardwares like 1)chasis 1000 2) DMM PCI-4060 3) SCXI -1331(2 in number) I have a system with two large glass plates standing vertically and placed parallel to the user.I am tryi
-
Lower quality when viewing in Preview
I have this issue on a BP with 10.5.4 and also a G4 with 10.4.11., and that is that images in Preview are not the same as viewed in any other app, which all look the same. I'm not talking about the look of colors or symptoms of having mismatched prof
-
Does Jsdk 1.4.2 supports JSF
Hi, Can some one please help me here I was tring to use JSF with the following combination, it is not even displaying the jsp page I was using Tomcat 5.5.23 with jsdk1.4.2 Thanks
-
Mac Pro with XP in boot camp - wireless speed fluctuates
I'm running XP on my Mac Pro, i installed all the latest drivers (from the leopard DVD and also from windows update) but i'm noticing very heavy fluctuations regarding my wireless network speed. When i look at "Wireless Network Connection Status", th