INPUT: KT4/V vs CRC error in large data transfer/CD burning HERE!

This issue can be solved with BIOS update. KT4V & KT4 Ultra users who are having this problem can request for the TEST BIOS to test on your system. You may either pm/email me or Bas, or get it at http://ftp://ftp.heppen.be/MSI/
Please report back whether the test BIOS would really fix the problem, or cause any new problem, or any performance hit.
** this sounds like a Christmas Gift to KT4V users AND New Year Gift to KT4 Ultra users!!!  :D  **
To all KT4 Ultra and KT4V users, either you have data corruption or CRC error in large data transfer and CD burning or not, your inputs are needed.
Please list down your system specs as details as possible. Below here is a guideline, you may take this, CTRL-C (copy) and write your specs in your post.
1. System specs:
CPU:
Motherboard:
RAM Slot-1: (exact brand and model)
RAM Slot-2:
RAM Slot-3:
display card:  [no overclock]
IDE-1M:  (exact HDD brand and model pls)
IDE-1S:
IDE-2M:
IDE-2S:
IDE-3:
SER-1:
SER-2:
PCI-1:
PCI-2:
PCI-3:
PCI-4:
PCI-5:
PCI-6:
PSU: (brand, model, total power, (estimated) combined power)
BIOS revision:
Operating System:
VIA 4-in-1 drivers : (if you installed it, tell us the version)
other drivers, services or applications might affect the data transfer such as : PCI Latency patch, WPCREDIT modifications, VCool, CoolerXP...
2. CRC ERROR?
PASS or FAIL
If PASS, let us know your BIOS settings.
If FAIL, proceed as below:
3. Please use these BIOS settings:
1. Load BIOS Setup Default
2. NO OVERCLOCK ON FSB! Set accordingly to your CPU
2. Set RAM to
a) SPD, if failed try
b) User defined to the slowest RAM timings, ie 266,2.5,3,6,3,disable interleave,4,disable 1T, normal
If PASS, go for more extreme BIOS settings as you usually use:
1. High Performance Default
2. set RAM to the extreme timings
3. DO NOT overclock yet until both 1. and 2. are PASS
4. Try these suggestions:
1. Microsoft IDE drivers (uninstall VIA 4-in-1's)
2. VIA 4-in-1 different version's IDE filter driver?
3. VIA IDE Miniport driver?
4. use IDE-3 RAID channel for one HDD data transfer
5. same HDD transfer, ie C:\dir1\*.* -> C:\dir2\*.*
6. burn CD at 1x speed
7. Set the HDD and/or CD to PIO mode, or slower UDMA mode.
8. If and only if you know how to update BIOS correctly and willing to take some risks, try the BETA BIOS KT4 (1.25), KT4V (1.64) too.
Please report back your tests and experimentations of these suggestions.
If you have any workaround to deal with this issue other than set back FSB to 100Mhz, please tell us too.
Thanks for your inputs!

My system, just gotten this 2 days ago
CPU: Athlon XP 2000+
Motherboard: MSI KT4V (MS-6712)
RAM Slot-1:
RAM Slot-2: 512 Mb Kingston DDR 333 CAS 2.5
RAM Slot-3:
display card: Abit Siluro GF3 Ti200
IDE-1M: Western Digital WD800JB (8 Mb Cache) - 80 GB
IDE-1S: Seagate U-Series ST360020A - 60 GB
IDE-2M: Sony DVD-ROM 16x (DDU1621)
IDE-2S: Creative CDRW121032
IDE-3:
SER-1:
SER-2:
PCI-1:
PCI-2:
PCI-3: Accton 1207F 10/100 Fast Ethernet Card
PCI-4: SBLIVE 5.1 Platinum with Live!Drive II
PCI-5:
PCI-6:
PSU: 400Watts (Generic)
BIOS revision: 1.6
Operating System: Windows 2000 with SP3
VIA 4-in-1 drivers : Hyperion 4.45, only AGP and INF installed. IDE drivers are standard Win2k/SP3 ones.
2. CRC ERROR?
FAIL.
When i had my system, i tried installing Windows ME as i wanted to do dual-booting together with Win2K. When i tried to install NVIDIA Detonator drivers (Ver 30.82), it proceeded as normally and asked for a reboot, which i did, then it just hang before the start of Windows ME. I did a reboot, and later selected "Normal" as Windows ME detected a failed startup, and later i was able to enter Windows ME, but it reported that the NVIDIA Detonator drivers were invalid and of wrong type to my display card.
Later i tried to move my files from my C:\ to D:\ and it reported saying that my destination file is invalid.
When i changed my OS to Win2k/SP3 (no more dual-boot), and installed the same NVIDIA detonator driver version, it worked. When i started to copy files again, it later BSOD, and said PAGE_FAULT_ERROR (something like this). When installing from CDs, it will report that my .CAB files are corrupt or have insufficient swap file space (i set mine manually at 1.2Gb size). Then there are times during my reboots and entering win2k, i found my keyboard and mouse (all PS/2) not working and windows loads as usual.
Later i changed my PCI latency setting from 32 to 96, i managed to install from CD without much further issues.
Upon reading these posts here, i didn't realize that the MSI KT4 series or the KT400 chipset had so much issues! i have read from countless sites like extremetech and anandtech and none reported about this particular errors i have encountered during my first 2 days with this setup. (this is my first Athlon setup, i'm previously and Intel person-type).
So far, i conclude in my settings is that:
-32-Bit settings in Bios settings for CD/DVD/CD-RW must be disabled, i concur with Shumway's recommendations.
-DMA settings in Windows 2000 for CD/DVD/CD-RW must be set to PIO mode otherwise when copying from CD to HDD will have read errors.
-Installing the PCI latency fix really does wonders for my set. (PCI Latency fix ver 1.9). Now i can copy files from all my drives without worrying so much about CRC errors. Thank you, George E. Breese.
-I really want to know why in WinME i can't install the NVIDIA detonator drivers, while in Win2K i can.
I post again, once i have done some more tests to my system, especially CD-R writes.
Angel17

Similar Messages

  • KT4 ULTRA + FSB133 = CRC ERROR !!!!!

    KT4 ULTRA + FSB133 = CRC ERROR !!!!!
    WHY ???
    KT4 ULTRA, Athlon 1800XP,256Mb333 Kingstone, GF2,WD 80Gb, IBM 40GB, CDRW, DVD, Live,
    PSU: 300W Codegen
    +3.3V - 20 A
    +5V - 30 A
    MAX 165 W
    +12V - 13 A
    -5V - 0.5 A
    -12V - 0.8 A
    Max 9.6W

    put codegen in search engine herelink
    all problems related to not enough juice
    also read this onelink

  • Errors in ALE data transfer to E-Recruiting.

    Hello,
    I need help with my ALE for E-Recruiting.
    We are on E-Rec 604 with seperated standlone e-rec system.
    We have set up ALE Data transfer for object type P from ECC QA to E-Rec QA system but unfortunately the I-Doc is always gettign posted with status 52.
    Those are the messages:
    Object 01 ,P ,01012021 does not exist: infotype 0105 cannot be created
    Object 01 ,P ,01012021 does not exist: infotype 0009 cannot be created
    Object 01 ,P ,01012021 does not exist: infotype 0006 cannot be created
    Diagnosis:
    You have tried to create infotype 0105 for plan version 01,object type P,object ID 01012021. However,the object does not exist.
    PA objects exist if infotypes 0000, 0001, and 0003 have been created.
    PB objects exist if infotypes 4000, 0001, and 0002 have been created.
    PD objects exist if infotype 1000 has been created.
    I followed the setting of "standalone" attachment to note 997181:
    HRSYNC_P                                    CONV_HR_DATA_TO_EREC (active as of Release 604)
    HRALE00INBOUND_IDOC             HRRCF00_INBD_NEWMOD (active as of Release 604)
    HRALE00SPLIT_INBOUND            HR_INB_PROCESS_IDOC (inactive as of Release 604)
    HRALE00INBOUND_IDOC             HRRCF00_DELETE_SPREL (inactive as of Release
    604)
    HRALE00SPLIT_INBOUND            HR_INB_PROCESS_IDOC (active up to Release 603)
    HRALE00INBOUND_IDOC             HRRCF00_DELETE_SPREL (active up to Release 603)
    So we have activated only the CONV_HR_DATA_TO_EREC and HRRCF00_INBD_NEWMOD because we are on 604.
    We have distributed Infotypes 0000, 0001, 0002, 0105 (Subtypes 0001 and 0010), 0006, and 0009 and I have to distribute the P - CP relation with 1001 A209.
    Somebody could help me please?.
    Thanks,
    Esther

    Hi Esther,
    Can you share you inputs how you have fixed the issue.
    Currently we are following I2 A Scenario according to the link
    http://help.sap.com/erp2005_ehp_05/helpdata/en/49/46037f06971ec6e10000000a42189b/frameset.htm
    DO we need activate the swiches  in HR System or Erec System.I believe it has to be in HR
    HRALX HRAC - X
    HRALX PBPHR ON
    HRALX USRAC X
    RECFA HRRFC
    RECFA RECCE
    RECFA DTCBA
    BADI do i need to activate only below one's
    HRSYNC_P
    CONV_HR_DATA_TO_EREC (active as of Release 604)   HR system
    HRALE00INBOUND_IDOC
    HRRCF00_INBD_NEWMOD (active as of Release 604)   Erec System.
    Correct me if im wrong.

  • Error in the Data Transfer phase

    Dear all,
    During the Data Transfer phase, we get 117 errors.
    The error for each failed process is:
    Execution of program /1CADMC/OLC_500000000043327 failed, return code               3
    Message no. DMC_RT_MSG046
    RC = 3: Error writing the data
    I compared the table structures in source and target system, and they are the same.
    Therefore I suspect that something went wrong during the Data Selection phase.
    Does anyone else have this problem?

    Hi Nicolas,
    Error code 3 suggests that there was a problem writing data to the receiver system. This may happen due to various reasons (For example: No tablespace available in the target system). To be sure, please check the System Logs (SM21) and Error Logs (ST22).
    In oder to check if something went wrong during data selection, you may refer to the selection logs for the tables for which data transfer is aborted.
    In case you are not able to identify the issue, kindly open an OSS Message for faster resolution of the problem.
    Regards,
    Suman

  • Error in Plan Data Transfer from CO

    Hi,
    I need to use Plan Data Transfer from CO (FM9C). But when I execute it, I have an error "CO Objects without FM Assgmt".
    How can I setup the derivation between CO and FM objects?
    All documentation that I've found are for SAP 4.6, but we are using SAP ECC 6.0...

    Hi,
    Are you using former budgeting or BCS? If you use BCS, you should use FMCYCOPI_CO. In any case, to link CO objects to FM entities, use FMDERIVE strategy - it works for planning in the same way as it does for real postings.
    Regards,
    Eli

  • Excel Throws an error for large data dumps

    Hi,
    I have a report in which displays 10,00,000 records , for that i created an agent and run the report the data is loaded into excel when we open the excel it is throwing an error
    I so mimimum i need to display 5,00,000 records
    Thanks,

    Hi,
    you can filter out some condition on report wise as well as dashboard wise using a prompts.
    Example:
    If u have Period table in the report filter out for year=2012 only
    or
    If u have prompt in dashboard filter out.
    in agent also we have the conditions rule while downloading the report.
    Check this makshu.blogspot.com\increase-row-limits-in-table-properties.html
    Regards
    VG

  • Excel shows an error for large data dumps

    Hi,
    I have a report in which displays 10,00,000 records , for that i created an agent and run the report the data is loaded into excel when we open the excel it is throwing an error
    I so mimimum i need to display 5,00,000 records
    Error is A DDE error has occured, and a description of the error cannot display becuase it is too long. If the file name or path is long, try renaming the file or copying it into a diffrent folder
    Thanks,

    Hi,
    you can filter out some condition on report wise as well as dashboard wise using a prompts.
    Example:
    If u have Period table in the report filter out for year=2012 only
    or
    If u have prompt in dashboard filter out.
    in agent also we have the conditions rule while downloading the report.
    Check this makshu.blogspot.com\increase-row-limits-in-table-properties.html
    Regards
    VG

  • Error 8 during data transfer from PSA - Cube

    Hello,
    when I want to load data from PSA to Cube I get "error 8 in update".
    I already had error 7 oder error 4 in the past, but what does this error 8 mean and how can I solve it?
    Thanks in advance

    The reason is this
    that if you try to load data records to the cube which is already archived. Please note that until the archives are not reloaded
    back, the same interval cannot be loaded.
    workaround in case of semantic lock is
    is to reload the data from archive -> semantic lock disappears -> load/update the data -> archive data again.

  • Error in Configuring Data Transfer From EMS to BAM using JMS

    Hi,
    Hi i am trying to import data from database into BAM dataobjects using JMS.
    I am able to get the data in JMS queue, but hav problem configuring BAM.
    After modifying the 2 xml files on BAM server and after making required changes on adminsrator on BAM console (Changing paths of jar files),
    I have to import some OBAM Artifacts. Refer
    - To import Oracle BAM artifacts needed for BAM server, perform the following steps,
    Copy $ORACLE_HOME/sysman/bam/emsys_all.xml into the BAM machine.
    Can anyone guide me to where can i get this file emsys_all.xml. I am not bale to locate it on my BAM server.

    Hi,
    The file that you referred to emsys_all.xml is for integrating BAM and Enterprise Manager
    More details on that can be found in
    Oracle® Enterprise Manager Management Connectors Integration Guide -
    http://www.oracle.com/technology/products/integration/bam/10.1.3/TechNotes/em_de.pdf
    However this is not required for EMS working, take a look at this document,
    http://www.oracle.com/technology/products/integration/bam/10.1.3/TechNotes/TechNote_BAM_Configurefor1013OC4J.pdf
    that gives the steps for EMS.
    Thanks
    Ranga

  • XML Large Data transfer

    I am trying to retrive about 3000 rows from a table and then converting it to XML using the oracle provided classes(oracle.xml.sql) and display it on IE 5.0/Netscape 4.5 but get a timeout ( I can do the same thing with 10 rows coming back ) with Oracle application Server 4.0.8 on Solaris 2.6 . And I am trying to figure out where its timing out .
    Thanks for your help in advance.
    Rajan
    null

    I assume that you've been successful in running this query from SQLPlus, and that it runs in a reasonable amount of time, if not you may need to tune your query or split it to make it run faster.
    Also, take a look at your servlet log and verify that you are not overrunning the StringBuffer. If you are you may want to make sure that you have configured the XSQL servlet properly. There's a parameter you can set that will not buffer the output. I can't remember what it's called but it's in the docs.
    Hope this helps,
    Mark
    null

  • Large data transfer hangs timecapsule

    While transfering many small files my time caspule hangs after a short while. I can still use the device from my Mac, but from windows the device is no longer existstant. Even webtraffic doesn't work.
    I'm using the latest timecapsule firmware 7.6.1 and the timecapsule is a model bought in 2011. I had hoped that the 7.6.1 firmware would solve the problem as 7.6 also had this issue.

    Click here and fill out the form.
    If desired, you can use the ditto command in the Terminal instead of the Finder to copy files.
    (122436)

  • Errors druing Data Transfer process

    Hello!
    I go through the SAP BW example and have the following error by generating Data Transfer process.
    I have corrected the errors (from "EURO" to "EUR") in CSV-files, but I get still the errors:
    No SID found for value 'EURO ' of characteristic 0CURRENCY
    No SID found for value 'U1 ' of characteristic 0UNIT
    I have recreated the flat files/.csv-files, deleted and created the info cube, but the error still occurs.
    What are the steps to fix the error?
    How can I know which data source contains the error?
    What are the possible values for 0CURRENCY and 0UNIT?
    Can some one give some recommendation?
    Thank you very much!
    rergards
    Thom

    Hello,
    You need to delete the data from PSA after an Unsuccessful load, if you want to load it again after correcting data in the source (Flat file in ur case). Right click ur datasource->Manage. Select the request which failed and hit the delete button (trash) at bottom. Now try loading it again.
    To get all possible values of currencies and units defined in your system. check contents of following tables:
    TCURC - Currency Codes (field -WAERS)
    T006 - Units of Measurement (field - MSEHI)
    Thanks

  • Input and CRC errors on ASA 5505 outside interface

    All,
    I see input and crc errors on my ASA 5505  eth0/0(outside) interface and packet drops. There is very slow connection though we have 20mb line. ISP also sees the issue on the Lan interface side. We have the speed and duplex configured same on both ISP and our end.
    I am suspecting if this is Physical cable issue. Please suggest.
      Hardware is 88E6095, BW 100 Mbps, DLY 100 usec
            Full-Duplex(Full-duplex), 100 Mbps(100 Mbps)
            Input flow control is unsupported, output flow control is unsupported
            Available but not configured via nameif
            MAC address 001a.b4c9.f3d9, MTU not set
            IP address unassigned
            158138067 packets input, 141061681082 bytes, 0 no buffer
            Received 183037 broadcasts, 0 runts, 0 giants
            19642 input errors, 19642 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
            0 pause input, 0 resume input
            0 L2 decode drops
            144684 switch ingress policy drops
            124291353 packets output, 38197278051 bytes, 0 underruns
            0 pause output, 0 resume output
            0 output errors, 0 collisions, 0 interface resets
            0 late collisions, 0 deferred
            0 rate limit drops
            0 switch egress policy drops
            0 input reset drops, 0 output reset drops

    Hello Ravi,
    This kind of issues CRCs/ Input Errors are tipically known as L1 issues so make sure you check the cable and if that does not make a difference change the port on each side to see if there is a difference.
    Unfortunetly the ASA does not support the Time-Domain Reflectometer feature so we must do the test of L1 by ourselfs.
    Can you clear the counters of the interface, test the changes provided and provide us some feedback?
    Looking for some Networking Assistance? 
    Contact me directly at [email protected]
    I will fix your problem ASAP.
    Cheers,
    Julio Carvajal Segura
    http://laguiadelnetworking.com

  • CRC errors and input errors on Te 1/2 of Cisco WS-C3560X-48 switch

    Hi All,
    I am observing CRC errors and input errors on one of the Te1/2 interface of WS-C3560X-48 Cisco switch. I have not observed any CRC errors or input errors on the connected interface at other end. Can you please let us know whether the issue is with cable or SFP module.
     Effected interface:
    TenGigabitEthernet1/2 is up, line protocol is up (connected)
      Hardware is Ten Gigabit Ethernet, address is f866.f243.e6b6 (bia f866.f243.e6b6)
      Description: *** MAN-SW1B***
      MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,
         reliability 254/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, loopback not set
      Keepalive not set
      Full-duplex, 10Gb/s, link type is auto, media type is SFP-10GBase-SR
      input flow-control is off, output flow-control is unsupported
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input 00:00:00, output 00:00:00, output hang never
      Last clearing of "show interface" counters 3w5d
      Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: fifo
      Output queue: 0/40 (size/max)
      5 minute input rate 29000 bits/sec, 30 packets/sec
      5 minute output rate 45000 bits/sec, 37 packets/sec
         68905128 packets input, 8272036576 bytes, 0 no buffer
         Received 68904979 broadcasts (68812046 multicasts)
         0 runts, 0 giants, 0 throttles
         146170 input errors, 130065 CRC, 0 frame, 0 overrun, 0 ignored
         0 watchdog, 68812046 multicast, 0 pause input
         0 input packets with dribble condition detected
         83524620 packets output, 12642123488 bytes, 0 underruns
         0 output errors, 0 collisions, 1 interface resets
         0 babbles, 0 late collision, 0 deferred
         0 lost carrier, 0 no carrier, 0 PAUSE output
         0 output buffer failures, 0 output buffers swapped out
    Other end.
    TenGigabitEthernet1/4 is up, line protocol is up (connected)
      Hardware is Ten Gigabit Ethernet Port, address is 503d.e53b.9703 (bia 503d.e53                                                                                        b.9703)
      Description: *** DMZ-SW1B ***
      MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,
         reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, loopback not set
      Keepalive set (10 sec)
      Full-duplex, 10Gb/s, link type is auto, media type is 10GBase-SR
      input flow-control is on, output flow-control is off
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input 00:00:00, output never, output hang never
      Last clearing of "show interface" counters never
      Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: fifo
      Output queue: 0/40 (size/max)
      5 minute input rate 32000 bits/sec, 27 packets/sec
      5 minute output rate 21000 bits/sec, 22 packets/sec
         918379921 packets input, 312586470396 bytes, 0 no buffer
         Received 881142868 broadcasts (875016400 multicasts)
         0 runts, 0 giants, 0 throttles
         0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
         0 input packets with dribble condition detected
         463132111 packets output, 240865283601 bytes, 0 underruns
         0 output errors, 0 collisions, 1 interface resets
         0 babbles, 0 late collision, 0 deferred
         0 lost carrier, 0 no carrier
         0 output buffer failures, 0 output buffers swapped out

    When there are more than two members in a cluster (stack), the Gigabit interface operates at half-duplex. Since collisions can result at half-duplex, some CRCs errors are normal.

  • CRC Error and input Error how can fix these

    FastEthernet0/13 is up, line protocol is up
      Hardware is Fast Ethernet, address is 0004.4d27.66cd (bia 0004.4d27.66cd)
      Description: EDL-P-Box-NO-4
      MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
         reliability 250/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, loopback not set
      Keepalive not set
      Auto-duplex (Full), Auto Speed (100), 100BaseTX/FX
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input 18:52:43, output 00:00:01, output hang never
      Last clearing of "show interface" counters never
      Queueing strategy: fifo
      Output queue 0/40, 0 drops; input queue 0/75, 0 drops
      5 minute input rate 12000 bits/sec, 6 packets/sec
      5 minute output rate 24000 bits/sec, 6 packets/sec
         14488019 packets input, 2783320210 bytes
         Received 345346 broadcasts, 0 runts, 0 giants, 0 throttles
         261028 input errors, 259429 CRC, 1599 frame, 0 overrun, 0 ignored
         0 watchdog, 84207 multicast
         0 input packets with dribble condition detected
         19658279 packets output, 3529106068 bytes, 0 underruns
         0 output errors, 0 collisions, 1 interface resets
         0 babbles, 0 late collision, 0 deferred
         0 lost carrier, 0 no carrier
         0 output buffer failures, 0 output buffers swapped out
    PAD-8-1-10.179#cle
    v

    Hi,
    Check out the below explanation for CRC error and farme error and few useful links to trouble shoot these type of problems
      The CRC error rate is 1.75915% (greater than 1 in a million packets),
      and the collision rate is less than 0.1%.
      This can indicate excessive noise or transmission problems on the LAN or the LAN
      bus itself. A high number of CRCs is usually the result of collisions or a station
      transmitting bad data.
      TRY THIS: Check cables to determine whether any are damaged. If 100BaseTX is being
      used, ensure Category 5 cabling is being used and not another type, such as Category
      3.
      There have been 1599 'frame errors' reported.
      This indicates the number of packets received incorrectly, having a CRC error
      and a non-integer number of octets. On a LAN, this is usually the result of collisions
      or a malfunctioning Ethernet device.
    TRY THIS: Monitor the level of frame errors over time. If they are increasing,
      try swapping interfaces and or ports to identify the problem.
    http://www.cisco.com/en/US/customer/products/hw/modules/ps2033/products_tech_note09186a008009446d.shtml
    http://www.cisco.com/en/US/docs/internetworking/troubleshooting/guide/tr1904.html
    http://www.cisco.com/en/US/docs/internetworking/troubleshooting/guide/tr1904.html
    Hope that helps out your query !!
    Regards
    Ganesh.H

Maybe you are looking for