Ins-08109 unexpected error occurred while validating inputs at state 'quick install'

Dear All,
I successfully configure clusterware for 2 node rac db. But when i try to install Oracle DB Software i am getting below error on 4 step .
ins-08109 unexpected error occurred while validating inputs at state 'quick install'.
Kindly advice over the same.
Thanks in advance.

Thanks John for your update,
Actually whenever i ask a question on OTN and Sybrand replied over the same every time instead of giving solution or advice he always try to insult other. I know that he is very senior to me and i am here posting query not to waste important time of anyone but to get the solution. Yes i forgot to update the i goggled and applied the recommendation before posting my query here. But this is not the correct way to advice anyone. Infact he also cross out this level where i am. If you think i hurt sentiments of anyone i feel sorry for that. But this is not the right way to advice in fact you all are seniors and we are coming here to learn from you guy's. OTN is not private property of anyone.
One thing more to say like you advice me calmly it's better to understand me how to do things accordingly now i will do that. Thanks again for your help and i will take care of all these things in future.
Actually the problem mentioned above i faced first time and after google i didn't get any blog or site with the same mentioned error instead it will give me link mentioned below:-
[Ins-08109] Unexpected Error Occurred 'Installoptionsui'.
But mine was
[ins-08109] unexpected error occurred while validating inputs at state 'quick install''
I tried one of the blog that states that similar problem occurs when clusterware is not up. First i check whether clusterware is up or not i found that it is up. But still i restarted it and try the installation again but getting the similar problem again.
In one blog it is mentioned that due to listener misconfiguration the problem occurs. I crosschecked listeners are configured from grid home.
So applied both the sol which i get by typing the same error which i mentioned above but not successful to get the solution.
In some website it is suggested that try to contact Oracle Support for the same.
Ok the problem is sorted out,I do a fresh installation of OS, Clusterware and DB, now i am not facing the same problem. I think the problem is related to group permission. Now this time i mention all the details what i do and what is the result i think now its better to understand.

Similar Messages

  • [INS-08109] Unexpected error occurred while validating inputs at state 'get

    Facing that on a windows 2003 server on installing 11gR2 on an installed 11.1.0.6
    [INS-08109] Unexpected error occurred while validating inputs at state 'getOCMDetails'.
    that's in the first step on the installer

    Very stupid installer !
    I've omitted my email, then pressed no in the next message, it passed that step!

  • INS-08109 Unexpected error occurred while validating inputs at state nodeselection page

    Scenerio: We have 4 node 11gr2 RAC cluster and Trying to install RAC Database software only on two nodes
    Getting warning on run Installer Page INS-08109 Unexpected error occurred while validating inputs at state nodeselection page while selecting two nodes out of four and even after confirming it comes back to same screen ....
    Example ... RAC node A,B,C,D  and clusterware is up and running on all four nodes .....
    Trying to Install RAC database on node C,D ... Getting INS-08109 Unexpected error occurred  while selecting C,D  Node out of Four nodes ...A,B,C,D

    Very stupid installer !
    I've omitted my email, then pressed no in the next message, it passed that step!

  • INS-08109 unexpected error occured while validating inputs at state 'nodeSe

    HI,
    I am installing and configuring oracle 11gr2 in vmware(OEL 4). I have installed successfully 11g grid successfully. Now i am trying to install oracle 11g rac software. While selecting the node, It shows the below error.
    INS-08109 unexpected error occured while validating inputs at state 'nodeSelectionPage'
    Cause:No additional information available
    Action: Contact Oracle Support services or refer to the software manual.
    Please help me solve this issue.

    u have resolved it . i has get the same issue.

  • [INS-08109] Unexpected error occurred 'InstallOptionsUI'.

    Hello.
    I have installed Oracle Clusterware 10.2.0.3 and I tried to upgrade to Grid Infraestructure 11.2.0.2. The plataform is solaris 10 in a sparc.
    When I run the installer I have a error and I cannot continue the install, I have a case open in metalink but I have no answer yet.
    This is the message and I hope you can help with that.
    +[INS-08109] Unexpected error occurred while validating inputs at state *'InstallOptionsUI'*.
    Cause - No additional information available.
    Action - Contact Oracle Support Services or refer to the software manual.
    Summary  - java.lang.NullPointerException+
    Regards,
    Milton

    Getting the same error when I try to install 11GR2 grid software:
    ./runInstaller -silent -responseFile /opt/apps/oracle/software/grid/response/tm_grid_install.rsp
    Starting Oracle Universal Installer...
    Checking Temp space: must be greater than 415 MB. Actual 16224 MB Passed
    Checking swap space: must be greater than 150 MB. Actual 92520 MB Passed
    Preparing to launch Oracle Universal Installer from /tmp/OraInstall2011-08-04_01-51-00PM. Please wait .../opt/apps/oracle/software/grid>
    [WARNING] [INS-08109] Unexpected error occurred while validating inputs at state 'InstallOptionsUI'.
    CAUSE: No additional information available.
    ACTION: Contact Oracle Support Services or refer to the software manual.
    SUMMARY:
    - java.lang.NullPointerException
    I installed the database software successfully, but the grid install fails with this error.
    Has Oracle come back to you yet?
    OK I found my problem.
    The install log file (found under INVENTORY_LOCATION/logs) pointed me to a missing parameter in my responseFile.
    In my case that was
    oracle.install.option=
    which I changed to
    oracle.install.option=CRS_SWONLY
    Edited by: nokia4me on Aug 4, 2011 2:05 PM

  • INS-08106: Unexpected error occurred while loading the 'InventoryUI'

    Hello.
    Have done alot of installs over time, but this error has me stymied. Here are the givens:
    2-node Linux RHEL 5 OS
    Will ASM over fiber (using ASMLib)
    Attempting to install Oracle 11gR2 (11.2.0.3.0)
    SSH is working and runcluvfy gives no errors on wither nodes.
    When running through the installer, I am on the "specify Installation Location" menu.
    I input Oracle Base: /apps/oracle
    I input Software Location: /apps/grid/product/11.2.0/grid_1
    I hit NEXT and afeter a short time, I get the following error:
    INS-08106: Unexpected error occurred while loading the view 'InventoryUI' associated to state 'inventory.'
    No further details are given.
    I look in the install log for this run and see these last final lines (no errors appear in this log prior):
    INFO: Gathering system details
    INFO: Checking specified location on remote nodes... (btw - specified path DO exist w/correct perms/ownership)
    INFO: size stimation for Completeinstall is 5632.0
    INFO: Completed validating state <CRSInstallLocationUI>
    INFO: Verifying route INVENTORY_ABSENT
    INFO: Get view names [InventoryUI]
    INFO: View for [InventoryUI] is oracle.install.ivw.common.view.InventroyUI@58046530
    INFO: Initializing view [InventoryUI> at state <inventory>
    INFO: Fetching existing UNIX groups
    INFO: Terminating all background processes
    INFO: Terminated all background procecces
    SEVERE: [FATAL] [INS-08016] Unexpected error occurred while loading the view 'InventoryUI' associated to state 'inventory.'
    CAUSE: No additional information available.
    ACTION: Contact Oracle Support Services or refer to the software manual..
    Refer associated stacktrace #oracle.install.commons.util.exception.DefaultErrorAdvisor:1032
    INFO: Advice is ABORT
    INFO: Adding ExitStatus FAILURE to the exist status set
    INFO: Finding the most appropriate exist status for the current application
    INFO: Exit Status is -1
    INFO: Shutdown Oracle Grid Infrastructure
    INFO: Unloading Setup Driver
    I realize I can open an SR in MOS, but was hping that maybe someone in this forum had encountered this error previosly and might have some sugestions or a solution that worked for them. The only same error code in MOS relates to to:
    Unexptected error occurred while loading the view 'GridPlugPlayInfoUI' associated to state 'GridPlugPlayInfoUI', but this has a fix in /etc/hosts, but is NOT the same error I am getting.
    Thank you in advance for any help.
    Matt

    /etc/hosts file was ok as-is.
    Here was the underlying problem that has now been fixed:
    We had three user goups associated with user Oracle. They were oinstall, dba, and oper
    In /etc/groups, "oper" was not present. During the install, but prior to the actual pressing of the "Install" button, check(s) are made between the groups tied to the installer user and what groups are associated with the same user in /etc/groups. Once "oper" was added to the /etc/groups file, the error disappeared and the install proceeded.
    Problem solved. Thanks for any earlier inputs.
    Matt

  • INS-08106] Unexpected error occurred while loading the view 'GridPlugPlayInfoUI'

    Hi
    I got the below error message while installing the Oracle 11g R2 Database Grid software on Oracle Linux 6.4 OS using vnc viewer.
    "INS-08106] Unexpected error occurred while loading the view 'GridPlugPlayInfoUI' associated to state 'GridPlugPlayInfoUI'."
    Please let me know how to overcome this error and proceed with the installation.
    Contents of the error log file:
    java.lang.NullPointerException
      at oracle.sysman.oii.oiin.OiinNetOps.addNICInfo(OiinNetOps.java:144)
      at oracle.sysman.oii.oiin.OiinNetOps.computeNICList(OiinNetOps.java:109)
      at oracle.sysman.oii.oiin.OiinNetOps.<init>(OiinNetOps.java:76)
      at oracle.sysman.oii.oiin.OiinNetOps.getNetOps(OiinNetOps.java:90)
      at oracle.sysman.oii.oiix.OiixNetOps.getFullHostName(OiixNetOps.java:49)
      at oracle.install.library.util.MachineInfo.getFullHostName(MachineInfo.java:109)
      at oracle.install.library.db.RAC92Info.is92RACPresent(RAC92Info.java:115)
      at oracle.install.ivw.crs.view.InstallTypeGUI.onEvent(InstallTypeGUI.java:120)
      at oracle.install.commons.flow.AbstractFlowExecutor.loadView(AbstractFlowExecutor.java:508)
      at oracle.install.commons.flow.AbstractGraphicalFlowExecutor.access$001(AbstractGraphicalFlowExecutor.java:39)
      at oracle.install.commons.flow.AbstractGraphicalFlowExecutor$1.call(AbstractGraphicalFlowExecutor.java:99)
      at oracle.install.commons.flow.AbstractGraphicalFlowExecutor$1.call(AbstractGraphicalFlowExecutor.java:98)
      at java.util.concurrent.FutureTask$Sync.innerRun(FutureTask.java:269)
      at java.util.concurrent.FutureTask.run(FutureTask.java:123)
      at java.awt.event.InvocationEvent.dispatch(InvocationEvent.java:209)
      at java.awt.EventQueue.dispatchEvent(EventQueue.java:461)
      at java.awt.EventDispatchThread.pumpOneEventForHierarchy(EventDispatchThread.java:242)
      at java.awt.EventDispatchThread.pumpEventsForHierarchy(EventDispatchThread.java:163)
      at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:157)
      at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:149)
      at java.awt.EventDispatchThread.run(EventDispatchThread.java:110)
    ---# Begin Stacktrace #---------------------------
    ID: oracle.install.commons.util.exception.DefaultErrorAdvisor:458
    oracle.install.commons.flow.FlowException: [INS-08106] Unexpected error occurred while loading the view 'GridPlugPlayInfoUI' associated to state 'GridPlugPlayInfoUI'.
      at oracle.install.commons.flow.AbstractFlowExecutor.loadView(AbstractFlowExecutor.java:510)
      at oracle.install.commons.flow.AbstractGraphicalFlowExecutor.access$001(AbstractGraphicalFlowExecutor.java:39)
      at oracle.install.commons.flow.AbstractGraphicalFlowExecutor$1.call(AbstractGraphicalFlowExecutor.java:99)
      at oracle.install.commons.flow.AbstractGraphicalFlowExecutor$1.call(AbstractGraphicalFlowExecutor.java:98)
      at java.util.concurrent.FutureTask$Sync.innerRun(FutureTask.java:269)
      at java.util.concurrent.FutureTask.run(FutureTask.java:123)
      at java.awt.event.InvocationEvent.dispatch(InvocationEvent.java:209)
      at java.awt.EventQueue.dispatchEvent(EventQueue.java:461)
      at java.awt.EventDispatchThread.pumpOneEventForHierarchy(EventDispatchThread.java:242)
      at java.awt.EventDispatchThread.pumpEventsForHierarchy(EventDispatchThread.java:163)
      at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:157)
      at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:149)
      at java.awt.EventDispatchThread.run(EventDispatchThread.java:110)
    Caused by: java.lang.NullPointerException
      at oracle.install.library.crs.CRSInfo.getDefaultIPAddressForGNSVIP(CRSInfo.java:584)
      at oracle.install.ivw.crs.view.GridPlugPlayInfoUI.onEvent(GridPlugPlayInfoUI.java:373)
      at oracle.install.commons.flow.AbstractFlowExecutor.loadView(AbstractFlowExecutor.java:508)
      ... 12 more
    ---# End Stacktrace #-----------------------------

    Hello,
    It's a Bug.
    Try selecting all languages and give a try ...
    Bug 9632373: UNEXPECTED ERROR OCCURRED WHILE LOADING THE VIEW 'GRIDPLUGPLAYINFOUI'
    <Moderator Edit - deleted MOS Doc content - pl do not post such content - it is a violation of your Support agreement>
    Thank you

  • [INS-08109]Unexpected error validating input-java.lang.NulpointerException

    RAC 11gR2 Grid installation:
    ================
    I got java.lang.NullpointerException during RAC 11gR2 cluster installation.
    [INS-08109] Unexpected error occurred while validating inputs at state QuickInstallUI'.
    Summary:java.lang.NullpointerException
    Are you sure you want to continue ?
    If you click yes it goes back to where to started and the same error would occurs again if you try again. If you click no it will just exit the installer.
    Any help is appreciated. Thanks.
    I cannot go ahead with this error.
    Please find attached screenshot.
    Before starting ./runInstaller i have done with all prerequisite checks and also run
    ./runcluvfy.sh stage -pre crsinst -n isvm-lnx-brm03,isvm-lnx-brm04 -verbose
    Thanks,

    Very stupid installer !
    I've omitted my email, then pressed no in the next message, it passed that step!

  • Upgrading to osx 10.6.8 fails. I see errors in the /var/log/install.log of "An unexpected error occurred while moving files to the final destination." Underlying Error=(Error Domain=NSPOSIXErrorDomain Code=5 "The operation couldn't be completed. Input/out

    upgrading to osx 10.6.8 fails. I see errors in the /var/log/install.log of "An unexpected error occurred while moving files to the final destination." Underlying Error=(Error Domain=NSPOSIXErrorDomain Code=5 "The operation couldn’t be completed. Input/out. Any thoughts on what is causing these errors and the upgrade failure?
    Thanks

    I have no idea what the specific error code means but input/output errors can sometimes mean a disk is failing. Make a couple of backups of all important data before doing anything else.
    Verify your startup disk using the First Aid tab in Disk Utility. If the disk needs repair boot from your Leopard DVD and repair your disk from Disk Utility under Utilities on the screen after you choose your language. Repeat the repair process until Disk Utility reports all is well.
    If Disk Utility doesn't find any errors you might want to try a new download of the update and keep a sharp eye on your HD for anything else that might indicate all is not well. Take special care to back up important data.
    If Disk Utility finds errors it would probably be a good idea to pay a visit to the Apple Store to have them check out your hard drive even if Disk Utility is able to repair the errors.

  • An unexpected error occurred while the job was running. (ID 104 Details: The parameter is incorrect (0x80070057))

    We are using DPM Version: 4.1.3465.0 with System Center 2012 Service Pack 1 to back up VMs in our Hyper V Cluster. We have a total of 37 VMs with a combination of 2008r2 servers and 2012 servers. One of our 2012 servers will not backup, and we consistently
    get the message "An unexpected error occurred while the job was running. (ID 104 Details: The parameter is incorrect (0x80070057))". I have seen this error message when I Googled it, but cannot get past it. I have deleted the Protection Group and
    data and tried to re-create, but get the same errors. I also thought the the server might be mis-reporting the data size, but I expanded that to cover the replication data. I have also tried to perform consistancy checks multiple times with no luck. I have
    not seen a difinitive answer from my Google searches, so was hopeful someone has seen this also, and have had success in resolving. Currently this server has no backup recovery points, so I am worried if it does crash. I think I have the rollups installed
    as well.

    Hi Kelly,
    does the issue still persists?

  • "An unexpected error occurred while creating a custom installer."

    All;
    I—and I've seen several others in older posts—have been reported received the error "An unexpected error occurred while creating a custom installer" while attampting to build a customer ARD client installer.  My guess is that this is do to a issue related to 10.8.X (10.8.4, in my case) based console Mac but I cannot confirm this. I have verified that there are no outstanding OS, client or application updates or hot fixes, as well.
    Has anyone built an successful installer from Mountain Lion-installed Mac?  Is there any know workarounds?
    Thanks in advance, for any help. 

    Have the exact same problem.
    iMac running 10.8.4
    Got through the steps of creating a custom client installer.
    if I choose not to customize and just save an installer I don't get the error but it creates a file of Zero bytes in size.
    If I chose to configure, when I try to save I get:
    An unexpected error occurred while creating a custom installer. Please try again....
    Console log reports:
    9/1/13 12:32:29.603 AM Remote Desktop[1306]: open on /private/tmp/RemoteDesktopClientInstaller_HEATyAJ5CR/extracted/RemoteDesktopCli ent.pkg/Scripts/RemoteDesktopClient.pkg: No such file or directory
    I have tried to save this in several location, with no effect on the error or the information logged, with the exception of the name of the temp directory that DOES contains the file (zero bytes):
    RemoteDesktopClient.pkg
    Need help with this someone...!
    APPLE...I JUST purchase this Applciation for $80.....it just flat out does not work....

  • An unexpected error occurred while the job was running. (ID: 104)

    I'm getting this error in the event logs when trying to run a consistency check / sync with one of our file servers.
    This server was working fine, but w needed to migrate the data to a new partition (GPT) to allow it to expand past the 2TB limit of MBR partitions.  I added a new 3TB disk migrated the data and changed the drive letter to what the old partition was
    prior.  Since then we seem to get this error.
    I have installed the update roll up on both the server and the agent side.  I have also removed the server from the protection group then re-added it.  I've also removed and reinstalled the agent on the file server.
    Any help is appreciated!  Here's the full error from the DPM server:
    The replica of E:\ on server is inconsistent with the protected data source. All protection activities for data source will fail until the replica is synchronized with consistency check. (ID: 3106)
    An unexpected error occurred while the job was running. (ID: 104)

    Server Version is Windows 2012 R2 STD.  DPM is 4.2.1235.0 (DPM 2012 R2).  I expanded the production file server.  All that server does is host up file shares.
    I suspected the fact that I created a new volume and changed drive letter back to the original to be the source cause of the issue.  What I ended up doing is blowing away the backups from this server on disk and re-adding it to the protection group. 
    It now runs much longer, but still times out at random with the error mentioned above.
    Vijay:  The error was copied from Event Viewer.  Not sure what else you require?  Event ID is 3106 from DPM-EM.
    The DPM logs say:
    Affected area: E:\
    Occurred since: 2015-01-05 2:04:38 AM
    Description: The replica of Volume E:\ on servername is inconsistent with the protected data source. All protection activities for data source will fail until the replica is synchronized with consistency check. You can recover data from existing recovery
    points, but new recovery points cannot be created until the replica is consistent.
    For SharePoint farm, recovery points will continue getting created with the databases that are consistent. To backup inconsistent databases, run a consistency check on the farm. (ID 3106)
     An unexpected error occurred while the job was running. (ID 104 Details: The semaphore timeout period has expired (0x80070079))
    Date inactivated: 2015-01-05 7:03:04 AM
    Recommended action: No action is required because this alert is inactive.
    Affected area: E:\
    Occurred since: 2015-01-05 2:04:38 AM
    Description: The replica of Volume E:\ on servername is inconsistent with the protected data source. All protection activities for data source will fail until the replica is synchronized with consistency check. You can recover data from existing
    recovery points, but new recovery points cannot be created until the replica is consistent.
    For SharePoint farm, recovery points will continue getting created with the databases that are consistent. To backup inconsistent databases, run a consistency check on the farm. (ID 3106)
     An unexpected error occurred while the job was running. (ID 104 Details: The semaphore timeout period has expired (0x80070079))

  • An unexpected error occurred while configuring the Network Bridge

    Windows XP Pro SP2, a new TP61 6460 6WG, all Win updates, all Lenovo updates.
    Everything works fine except... when I'm trying to create a network bridge I always get the following: An unexpected error occurred while configuring the Network Bridge.
    This is not the situation described in Microsoft's Knowledge Base KB309640 (http://support.microsoft.com/kb/309640/en-us). I have no ICS, no ICF.
    Any ideas?

    I had the same problem and was really frustrated. I was about to pull my hairs out but then i was finally able to solve it. The solution is deleting some files of WMI repository. The complete details can be found on my blog http://cheatppc.blogspot.com/2008/07/unexpected-error-has-occured-while.html
    Hope this solves the problem.

  • An unexpected error occurred during validation

    Hi Ramesh,
    This is Jaden I work with Shamik :)
    We had the following question we were hoping you could help us with.
    We are trying to recieve a 850 document in the b2b server. We get the following error - An unexpected error occurred during validation
    our document we recieve is below. We use the document analizer and the document validates against the .ecs file fine. We notice that the server is missing the b2b log any thoughts?
    ISA~00~ ~00~ ~ZZ~Allied ~ZZ~UPS ~070721~1459~U~00200~000001008~0~P~+'GS~PO~Allied~UPS~20070721~1459~1008~X~004010'ST~850~1008'BEG~00~SA~60009~86974~20070717'DTM~010~20070717'TD5~~2~000001_DHL_A_2DA'N1~ST~19427~92~7984'N3~500 Oracle Pkwy'N4~Redwood City~CA~96504~US'N1~BT~19427~92~7984'N3~500 Oracle Pkwy'N4~Redwood City~CA~96504~US'PO1~1.1~1~EA~~~VP~50934~~~DV~255154'PID~F~~~~3PL Test Item with Lot Control'PO1~2.1~2~EA~~~VP~50936~~~DV~255155'PID~F~~~~3PL Test Item with Serial Control'PO1~3.1~3~EA~~~VP~50935~~~DV~255156'PID~F~~~~3PL Test Item with Locator Control'PO1~4.1~4~EA~~~VP~50936~~~DV~255157'PID~F~~~~3PL Test Item with Serial Control'PO1~5.1~100~EA~~~VP~50936~~~DV~255158'PID~F~~~~3PL Test Item with Serial Control'SE~21~1008'GE~1~1008'IEA~1~000001008'

    Hello jaden,
    Please edit tip.properties as follows and restart b2b. The log file will be generated at OH/ip/log/b2b/b2b.log.
    oracle.tip.LogType=text
    b2b.oracle.tip.DiagnosticLevel.B2B=DEBUG
    Make sure the delimiter used as part of configuring the document, i.e Document Protocol parameters are appropriate. The document might have validated in the spec builder as the delimter which is defined there might be different.
    Please setup a quick call if you still face issues.
    Rgds,
    Ramesh

  • An unexpected error occurred while the job was running. (ID 104 Details: The parameter is incorrect (0x80070057)) After DPM 2012 SP1 to R2 Upgrade

    Hi,
    We have upgraded DPM 2012 SP1 to DPM 2012 R2 and OS is Windows 2012 standard.
    Now in File Protection Group, we receive error
    "An unexpected error occurred while the job was running. (ID 104 Details: The parameter is incorrect (0x80070057))".
    This happens to only one Drive(X: Drive) of the PG server, other drive(Z: Drive) backup is working fine.
    We tried,
    Deleted entire protection group and recreated ,
    Ran consistency job 2 to 3 times.
    Ran Synchronize with consistency check.
    But every time It failed. Before upgrade it was working fine.
    Thanks

    Hi
    I would suggest opening a new case with MS to allow the DPM team to further look into the issue. Also the DPM 2012 R2 RollUp which addresses the (0x80070057)
    issue is Rollup 1 and the private will not be needed after applying Rollup 1. The Roll up is found here
    http://support.microsoft.com/kb/2904687/en-us
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your
    question. This can be beneficial to other community members reading the thread. Regards, Dwayne Jackson II. [MSFT] This posting is provided "AS IS" with no warranties, and confers no rights."

Maybe you are looking for

  • Can i move everything from my iphone to a new computer without losing my messages (iphone 3gs)

    Hi, Em i am wondering if there is any possible way to move everything from my phone to a new computer because i lost my old computer and dont want to lose everything. If not is there even any way i can just keep my messages. If i have 2 lose my music

  • Apps won't update! iPod touch 2nd gen!

    I have a almost brand new ipod touch and normally when i have wifi little red numbers will pop up about undates for pre-existing apps, & ill just click "update all" and it works. but now, I press "update all" and it starts to work and then a little m

  • How do i find or replace the missing disk image for my HD

    How do i find or replace the missing disk image? for my HD ........as it is missing when i try to back up with time machine,  i asked for assistance the other day with time machine now i have worked out this is the reason i can not back up with TM, d

  • Equivalent for TOP 1 of SQL Server used in subqueries

    Hi all, I am trying to migrate a sql query from SQL Server to Oracle 9i, which uses the SQL Server TOP keyword in correlated subqueries. How should I write it in Oracle? The query is more complicated, but in principle looks like: SELECT TAB1.t1_id, T

  • Stock transports of vendor consigned inventory

    Hello.  I have a question with regard to doing a stock transport order (from one plant to another) where the inventory is in vendor consigment stock.  I have a stock determination rule set on both the materail and item category (NLN) but it appears I