Integration to CA Spectrum

Hi all,
Is there an integration for Orchestrator from CA Spectrum 9.3 and up?
We want to push alerts from Spectrum to Service Manager
If there's no integration pack for Spectrum, can the integration kit be used to build one?
Regards, Kurt

Hi,
you'll see the Activities of the IP here:
http://www.sc-orchestrator.eu/index.php/integration-packs/integration-packs-von-kelverion/integration-pack-fuer-ca-spectrum
With this and the Activities for SC Service Manager (http://www.sc-orchestrator.eu/index.php/integration-packs/integration-packs-von-microsoft/integration-pack-fuer-system-center-2012-service-manager)
youn can create a Runbook like this easily:
Regards,
Stefan
www.sc-orchestrator.eu ,
Blog sc-orchestrator.eu

Similar Messages

  • CA Spectrum to PI integration

    Hi All,
    I have requirement integrating with CA Spectrum to PI integration to SAP ECC.
    Can you please suggest how to integrate CA Spectrum to PI integration?
    CA Spectrum is CA product, it is count  the bandwidth of the networks.
    Regards,
    Ramesh

    Hi,
    Ramesh You are correct,CA Spectrum provides analysys of WAN,NetWork realted info.
    Fist understand your requirement that evry day CA Spectrum provindg info at some particulra time in the format of Text file take it as example,If it is the case the text info placing somewhere in File server or some other place,in this you can use file adapter in sender side and receiver side use IDoc.
    if it is not your requirement then you want to conenct to CA Specturm then betetr to develop OutBound JAVA Proxy to read info form directly,but put some more efforts to anyyze the requirement.
    there is no standard content availble from SAP,my advice is to go for Proxy.
    Regards,
    Raj

  • Integrating oracle with NMS? --URGENT

    hi all!
    this is very urgent!
    i have 10g database running on rhel4. it is using the database control. We have Aprisma Spectrum working as the NETWORK MONITORING SYSTEM which uses SNMP POLLS. They are pulling info from all the servers using spectrum.
    I am asked to configure the oracle database so that spectrum can pull information from the database.
    i have gone through the internet, and the info which i got is that, i need to integrate oracle sub-agent to the agent already running on the server (snmpd).
    do i need to install oracle management agent or the em sub-agent is sufficient.to be integrated with the spectrum management agent running on the server?
    if so, how do we configure?

    hey hernandez!
    thanks for the reply. i did happen to look into your postings on the
    Agent configuration Assistant FAILED
    My question is, can't we configure the subagent of EM database control to configure with the snmpd daemons running on the host which talk to the management service like aprisma spectrum??
    is it necessary that i need to install the grid control in my network and than install the oracle managment agents on all the database host (to be monitored)?
    can't i install only the oracle management agent on the host and configure it to work with the aprisma spectrum master agent running on the host (snmpd daemons) (and will not have to install the grid control)??
    please clarify !!!

  • Time & Payroll Integration

    Hello Gurus
    I went through many threads regarding Time & Payroll Integration. I didnt get clear picture of it. Can any one tell me where exactly this integration done. I know it will be done in IT 0007 (If I am not wrong).  Can some one explain me in detail.
    Points assured..
    Regards
    Raj

    Dear Raj,
    Infotype 0007 does have some influence on 0008, but it is limited to the number of hours defined in the work schedule.
    In wide spectrum, the time wage types are used and they are validated through the ZL tables in the time evaluation, and are linked into the payroll schema.
    Just by configuring the 7 infotype does not ensure that your Time and Payroll are integrated.
    Regards
    Naaga.

  • Audio Frequency Spectrum

    Hi,
    I'm looking for an FCE feature (3.5), or a Soundtrack feature (1.5) that allows to display the audio +frequency spectrum+ of a selection of an audio clip. My purpose is to analyze frequencies for a section of audio (e.g. a voice or a noise), identify a frequency range to fix, and modify its gain by using the standard FCE +3 Band Equalizer+ filter or the +AUGraphic EQ+ filter (or others).
    I can already use these 2 filters, but without a preliminary analysis of the spectrum I have to guess the frequency ranges. Of course the best solution would be to have a dynamic real time display, during audio playback... (BTW iTunes has something like that in the top center of the main window: it's just missing precision and details about frequency values, and dBs... - not really useful).
    I found something close to my needs in Audacity: the problem is that it is not integrated with FCE and that it is a static display. Or at least this is what it seems to me... I might have missed something.
    Does an audio frequency spectrum display exist in FCE HD, or in the bundled Soundtrack ?
    Thanks a lot
    Piero
    (since I didn't find any mention of this kind of display in this forum or in the Soundtrack forum - frequency or spectrum search do not return any topic - does this mean I'm looking for something that does not make sense... ? or are there other ways to do what I'd like and I described above ?)

    Thanks Ian and Tom.
    Yes, the Fourier Spectrum Analysis is what I need, and Sound Studio is providing it. I'm trying to figure out how to make the best use of it. In fact I hope there is a way to display it in real time, so I can see the frequency picks moving. That would be very helpful.
    In any case thanks for your help.
    Piero

  • Spectrum One CCD 3000 GPIB 488.2

    I have a JobinYvon Spectrum ONE CCD 3000 and I am controlling it with LabVIEW 5.1 on windows 98. I can run the image acquisition vi but after it takes one image, it freezes the connection to the ccd controller. So if I try to rerun the vi, or any other vi communicating to the ccd, it doesn't work. Has anyone come up with a solution to this problem or has anyone come across it before? Is it a hardware or software problem.
    I thought perhaps the vi's were causing a problem with the ccd because it is Liquid Nitrogen cooled and this is not meant to be done unless the ccd is initialized, but there is no way to just initialize the ccd with labview that I can see. Any thoughts?

    Dear Shellpetal
    The initialization of the camera has nothing to do with its cooling. The controller (the big box) has a heater circuit controlling the Temperature (Set to 140K).
    There are manuals (1) and (2) which should help you understanding the init process.
    Image acquisition (depending on the binning) takes with today's state of the art PCs and the desired (see manual 1) NI GPIB card up to 15 seconds with an integration time of 1000ms.
    Sending malformed commands (slightly wrong syntax) can crash the controller easily. Therefore: Go to NI MAX, Open a VISA session with the controller and send a the string "\DE" without "\r".
    It is what they call "\<222>" in the manual. This resets the controller to the so called boot-mode.
    Actually, all the numbers you will see in the manual that are in those <> brackets should be converted to hex. \<222> will be \DE.
    Please use 'Query' to send the command to get a immediate response.
    You can probe the state of the controller sending a "\s" (whitespace, again without term(ination) char(acter)). It should reply with "B" for boot mode.
    After initialization it will respond with "F". If you get a "b" this means that your command could not be identified. In order to bring the controller from Boot to Main send the command "O2000\00" (now with the term char \00 or \x00). After probing with "\s" you should get "F" now as a response.
    Now, use the CCDInit.VI in the LIB\CCD_sup_llb directory and try to init the CCD or the Demo VIs in LIB\CCD_demo_llb. There, the CCD is being initialized before doing anything.
    I attached the VIs to control the CCD. I suppose you are not working with that thing after 7 years but maybe somebody else does.
    Good luck and have a nice day.
     JW
    Attachments:
    JY-CCD3000V.zip ‏680 KB
    ni-max-visa.zip ‏116 KB

  • Power spectrum density question: One sided convert

    Hi, there
    I am using the PSD function. In order to get the RMS noise, I integrated the PSD data and doubled the result because I have two sides in positive frequency range and negative frequency range. Then my result is 1.414 (or Sqrt(2)) times higher than my RMS data measured in time domain.
    Then I looked into the PSD fuction and found out that in the function of  "Convert to on-sided spectrum", the amplitude was doubled. But it is not meantioned in the help file.
    My thinking is: either change the help file of PSD function and mention that it is a doubled one-sided output or do not double the amplitude when convert the spectrum from two-sided to one-sided output.
    best regards
    Chengquan Li
    CQ

    Dr. Chengquan Li,
    I know sometimes the help can be hard to navigate, but I think I found the help documentation that address this issue.  It can be found here: Power Spectrum.  
    Under the heading "Converting a Two-Sided Power Spectrum to a Single-Sided Power Spectrum", you can find the following:
    "A two-sided power spectrum displays half the energy at the positive frequency and half the energy at the negative frequency. Therefore, to convert a two-sided spectrum to a single-sided spectrum, you discard the second half of the array and multiply every point except for DC by two, as shown in the following equations."
    This is why you noticed that the block diagram of "Convert to One-Sided Spectrum" had the output doubled.  I hope this helps clear up the issue.
    Regards,
    Elizabeth K. 
    National Instruments | Applications Engineer | www.ni.com/support 

  • I want to use a labview spectrum analyzer for 2.4GHz anylizer

    I am trying to build a 2.4GHz antenna for a class reasearch project. and I want to use a labview Spectrum analizer to test it. But the boards we have in our lab only support frequencies of 2KHz. I was wondering if NI made a DAQ board that would support this frequency and exactly what is it.

    The PXI-5660 and associated software (Spectral Measurements Toolkit, Modulation Toolkit) are very tightly integrated with LabVIEW. I might be unclear as to your situation, but I will look at this from two perspectives:
    Hardware perspective:
    If you are testing a 2.4 GHz antenna, if you wanted a digitizer to simply digitize the output of the antenna, it would have to run at a sampling rate of at least 4.8 GSamples/sec due to the Nyquist Sampling Theorem. Other options include placing an RF downconverter in front of a digitizer. The downconverter then shifts the signal of interest to a lower frequency, which also lowers the Nyquist ctiterion, allowing lower sampling rates to be used.
    None of NI's DAQ boards can sample fast enough to captu
    re RF signals, unless there is some form of signal conditioning on the front end, like a downconverter. The PXI-5660 RF Signal Analyzer uses this approach.
    Software perspective:
    Once the data is acquired, it can easily be analyzed with LabVIEW analysis VIs and with the new Modulation and Spectral Measurements Toolkits (both in LabVIEW). Regardless of how you acquire the data, LabVIEW can analyze it.

  • Integrating a frequency domain signal

    Hi
    I am trying to extract the response of a frequency dependent signal :
    1. First, I use the SignalFFT vi to get into the frequency domain.
    2. Then I plan to integrate the FFT signal around a certain frequency and take a ratio of that wrt to the integral over the entire frequency spectrum to get a measure of how strong the signal is around that frequency.
    I am choosing a range of frequencies above because the physical phenomenon producing the time domain signal produces a certain lifetime width. I need a numerical integration VI that can do step 2 above. The numerical integration VI that I found in Labview (using ver. 7.1) integrates the whole signal, and there is no way to define limits between which the numerical integration should be carried out.
    Any ideas ?
    Thanks.

    That a cool question!
    This has to do with the sample rate, when you adquire the signal, you get set of samples, that hava a sample rate, and when you do an FFT on those samples, every sample corresponds to frecuency bin (kinda of frecuency samples). Example:
    If you get 100 samples at 1kHz, you will get a 100 windows, this is 100 samples to represent 1kHz, however, only the half of the spectrum is valid, because of the Nyquist teorem, so this mean that from 0 to 49, you have a correct representation, from 50 to 99 you have a reflection of the spectrum. So in the first 50 "frequency samples" you have 0-500Hz
    Tania Lozoya

  • Refresh System Data in Integration Directory PI 7.11

    Hey,
    I have setup a new technical system and a business system in SLD, but now I still can't find it in Integration Directory.
    I knew from the later PI Version, that there was an option to transfer SLD data to integration directory, but now I can't find it
    anymore.
    Can anybody help?
    Thanks!
    Michael

    I have setup a new technical system and a business system in SLD, but now I still can't find it in Integration Directory.
    I knew from the later PI Version, that there was an option to transfer SLD data to integration directory, but now I can't find it
    Tools (or right-click in ID) --> Assign Business System --> follow the wizard...it will assign the business system from SLD to ID

  • How can I get a new copy of the Voicemail app for my LG Spectrum?

    How can I get a new copy of the Voicemail app for my LG Spectrum?  It no longer works....the screen say Loading please wait....the
    !Visual Voice Mail - A Visual Voice Mail error has occurred.  Please try again. OK   I've tryed several times with the same message.  I've
    deleted the app from my screen and replaced it from the Apps Library....still the same message.
    I cannot find an answer on MyVerizon.  Any ideas?
    Thank you,
    Dee

    OK, at least 3 is working.
    I don't know how you have a Tape Recorder icon on your Home Screen. I cannot add one myself. But, I am running Holo Launcher in replacement of the default LG "Optimus" User Interface. It's much better in my opinion.
    Try long pressing the icon and select Edit and maybe you can change some attribute of the icon.
    Another thing you could do, is long-press an empty area of your desktop, to add an icon. Select Shortcut, then Select Contact, and scroll through your contact list and choose the contact that you added for *86.
    You realize if you have voice mail you haven't heard, there is a tape recorder icon in the notification bar, which you touch and pull down, then press it to dial voicemail.
    If that functionality doesn't work, you MIGHT want to consider doing a factory data reset on your device, but that is going to nuke all your personalizations and cause you work to set up again.

  • What is new AT&T iPhone MMS date? I see integrated messaging feature

    Okay, I heard that this was to happen at then end of Summer, then end of July.
    So what is the new date? I see Integrated Messaging counters in my AT&T profile as of this week.
    Should we expect another update to sync with iTunes to get it working?

    Funny. I'm going to mark this question as answered -and this last post as funny.
    I hope it isn't sarcasm, cause my sarcasm detector runs on Windows 7 and I currently have my VMware Fusion session powered off.
    The heart of my question was really the "integrated message" counter in my AT&T profile. I was hoping to hear others just got it, or don't have it, or when they got it, and they I could magically extrapolate a new MMS rumor date.
    Anyway, I don't have to go to UK (although a good choice), cause Rogers in Canada has MMS already.
    One Mac. One World.

  • How to print Integrity sql in the preparedstatement?

    How to print Integrity sql in the preparedstatement?
    Connection conn = null;
    String sql = "select * from person where name=?";
    PreparedStatement ps = conn.prepareStatement(sql);
    ps.setObject(1, "robin");
    ps.executeQuery();
    i'm wants print Integrity sql.
    For example:select * from person where name='robin'
    How should I do?
    thanks a lot!

    PreparedStatement doesn't offer methods for that. You can write your own implementation of PreparedStatement which wraps the originating PreparedStatement and saves the set* values and writes it to the toString().
    If needed, myself I just print the sql as well as the values-being-set to the debug statement.Logger.debug(query + " " + values);

  • Can i use OER to store the data from a excel sheet that pertains to the entire integrations ?

    hi ,
    i know that the OER can be used to view the entire landscape for the SOA composites and how they are related with each other. However we have a requirement wherein we need to store the data for the entire integration end systems e.g. ebiz, mfgpro, siebel etc ( that is we need to store data one level up).
    Also,  we want a customized form in OER wherein user can manually add data regarding the integrations.
    So is it possible to do so ? If yes, how ?

    ok, let me put it this way,
    I tried using the import/export utility available under OER admin tab.
    When i export my existing assets it generates the .xml file for each asset. Now as i have hundreds on new assets to be created for each asset type i want to be able to create a new .xml file and want it to create the new asset once i import it using import utility. I tried creating a new .xml file giving it a new UUID but it does not seem to work. Has anyone tried this earlier who can give the steps to do this ?

  • Assigning a node value from an XML variable to a String type  in Weblogic Process Integrator

    Hi,
    Is there any way to assign a node value from an XML variable to a String variable
    in Weblogic Process Integrator...
    Thanx.
    Narendra.

    Nerendra
    Are you talking about using Xpath on the XML document and assigning to a
    variable, it is unclear what you are asking
    Tony
    "Narendra" <[email protected]> wrote in message
    news:3bba1215$[email protected]..
    >
    Hi,
    Is there any way to assign a node value from an XML variable to a Stringvariable
    in Weblogic Process Integrator...
    Thanx.
    Narendra.

Maybe you are looking for

  • AGING is'nt working.

    about AGING system environments: oracle 10.2.0.5 timesten 11.2.1 Commands to create cache group Create DYNAMIC Asynchronous WriteThrough Cache Group CA_SILOG from UTELT.SILOG ( recvtime TIMESTAMP(6) NOT NULL, Rid Integer, HostName Varchar2(5), ProcNa

  • How do I set up for Help with CS5.5? I don't have CS6 but that is the only thing I seem to be able to get help on.

    When I select Help from the toolbar, I get more help than I ever imagined, for versions I don't have. How do I narrow it down to JUST the version I have?

  • Question: JDev10g features

    1) Navigator What is the difference between the "Applications - Navigator" and the "System - Navigator" (Besides the allowed use of "Directory tree" and "File List" viewstyles, and the "Show all files" option)? 2) Connections, SCM/Designer And also,

  • Fastest conversion in compressor

    what settings in compressor will give the fastest conversion from a final cut reference movie into a compressed format that can be played on a windows computer? i am not concerned about video quality. i just need to share a rough edit with my clients

  • How to size a proxy server

    Can anyone provide insight into how to size a proxy server? We would be using SUN hardware... Most importantly, type of server to buy, memory, number and configuration of cache disks. For specifics.... we would have about 4000 users, and would spread