Interconnecting CIsco MDS 9222i to the HP C-Blade enclosute VC-FC Virtual connect module

Hi,
Anyone had the experience of interconnecting the CIsco MDS 9222i to an HP Blade system through the VC-FC virtual connect module?
When i connect my MDS switch to the module, the VC-FC ports dont log in to the MDS. Could i be missing out on something? I have configured the MDS to use the default VSAN 1 and tried configuring the ports as F-ports but nothing worked, even with the port mode put on auto they still take on the F-port role and still the VC-FC module doesnt log in.
Your help and support will be appreciated
jerrysimila

i wanna use the CLI though i also have the fabric manager at my disposal. would you kindly
share a sanitised version of ur running config for the mds that does the FCIP replication to the DR i see if i can make head out of it then i
f i face any challenge will holla at u. you can email me [email protected]
My set up is as follows, ive got 2 MDS 9222i at the primary site in active-standby mode, one connects to the active VC while the other connects to the standby VC of the blade system. Then i have a similar set up for the DR. Good thing is that am first setting everything up here in my Data Centre, then test before sending the configured equipment to the DR. So i have much freedom to get dirty with the equipment, and its not a live environment yet.
Kindly let me know the step-by-step procedure of having the FCIP set up.

Similar Messages

  • Cisco MDS 9222i 10G Module DS-X9704 supports FCoE

    Hi, Whether Cisco MDS 9222i 10G Module  DS-X9704 supports FCoE? i saw IP over FC in the data sheet of this module but not FCoE?
    Thanks
    Abhilash

    Also whether this 10 G interface can work as an Ethernet port and not just a FiberChannel port?

  • How to factory default cisco MDS 9222i

    How to factory default cisco MDS 9222i

    Hi,
    write erase
    write erase boot
    reload
    (If prompted to save run to start, say no)
    http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/cli_4_1/bb.html#wp1087208
    Regards,
    David

  • Cisco MDS 9222i san switch

    need to know the license means which has been shown "Evaluation mode" in attached snap shot at Fabric Manager and its remedy.

    any update on this

  • Connecting Fabric Interconnect with MDS

    Dear Team,
    Kindly share how to configure connectivity between Fabric Interconnect and MDS
    what are the steps to be followed in establishing a successful connection between FI and MDS
    We have a tape library from IBM and trying to connect the same to FI via MDS and want this Tape library to be detected on the guest VM running windows 2008 on Esxi( Service profile with 2 vhba already added),we are trying using Fibre connectivity.
    Also please advice in which mode should we keep the FI (FC switching,end host etc)
    Thanks and Regards
    Jose

    Hi Jose,
    The common steps to configure FC on FI and MDS as following :
    1. FI configured in NPV mode, ensure that all FC uplinks and vHBA of Blades have been assigned on correct VSAN
        Verify if vHBA Flogi into the FI
        show npv flogi-table
        show npv status
    Example
    FI-A(nxos)# sh npv flogi-table
    SERVER                                                                  EXTERNAL
    INTERFACE VSAN FCID             PORT NAME               NODE NAME       INTERFACE
    vfc703    10   0x330001 20:00:00:cc:1e:dc:01:0a 20:00:00:25:b5:00:00:03 San-po102
    vfc711    10   0x330002 20:00:00:cc:1e:dc:02:0a 20:00:00:25:b5:00:00:02 San-po102
    Total number of flogi = 2.
    FI-A(nxos)# sh npv status
    npiv is enabled
    disruptive load balancing is disabled
    External Interfaces:
    ====================
      Interface: san-port-channel 102, State: Up
            VSAN:   10, State: Up, FCID: 0x330000
      Number of External Interfaces: 1
    Server Interfaces:
    ==================
      Interface: vfc703, VSAN:   10, State: Up
      Interface: vfc711, VSAN:   10, State: Up
      Number of Server Interfaces: 2
    2. Enable NPIV mode on MDS, configure the link to FI as F port. Assign this port into correct VSAN
        FI will become Node proxy, so verify if all vHBA have been detect on Upstream NPIV switch
    SW2(config)# sh npiv status
    NPIV is enabled
    SW2(config)# sh flogi database
    INTERFACE        VSAN    FCID           PORT NAME               NODE NAME      
    San-po102        10    0x330000  24:66:00:2a:6a:05:e9:00 20:0a:00:2a:6a:05:e9:01
    San-po102        10    0x330001  20:00:00:cc:1e:dc:01:0a 20:00:00:25:b5:00:00:03
                               [BLADE1-SAN-A]
    San-po102        10    0x330002  20:00:00:cc:1e:dc:02:0a 20:00:00:25:b5:00:00:02
                               [BLADE2-SAN-A]
    3. Configure zoning on the MDS (to make sure whether the issue on zoning or not, you can configure the default zone to permit)
    Example : zone default-zone permit vsan 1
    Verify the zoning on Upstream NPIV switch
    SW2(config)# SH ZONESet active vsan 10
    zoneset name ZONESET-VSAN10 vsan 10
      zone name INE-VSAN10 vsan 10
      * fcid 0x330001 [device-alias BLADE1-SAN-A]
      * fcid 0x330002 [device-alias BLADE2-SAN-A]
      * fcid 0x2a0000 [device-alias FC-SAN10]
    4. Ensure that vHBA of BLADE had been discovered on the storage device. Configure LUN masking on the storage
    I really don't have enough knowledge of VMware hahaha.....so can't help for troubleshooting the VM....Really sorry
    Thanks,
    Gofi

  • The Cisco MDS 9000 Port Analyzer Adapter

    Hi,
    At my client place, we are having an issue with BackUp via TSM and a library.
    We would like to analyse the traffic that pass in the Fiber Channel of our MDS-9513.
    From what we saw, Wireshark, our soft to analyse network traffic is only using NIC card to analyse.
    Is the only way to analyse the FC traffic to pass via "The Cisco MDS 9000 Port Analyzer Adapter" ?
    If that is the only way, is there a way tor ent this equipment for the time necesery to analyse our trace ?
    Thank you in advance for you help.
    Christian Carrier

    The Cisco Traffic Analyzer provides real-time analysis of SPAN traffic or analysis of captured traffic through a Web browser user interface. Traffic encapsulated by one or more Port Analyzer Adapters can be analyzed concurrently with a single PC and ntop, which is public domain software enhanced by Cisco for Fibre Channel traffic analysis. This Cisco Traffic Analyzer solution enables you to quickly determine the throughput for traffic between specific Fibre Channel sources and destinations, all traffic in a particular Virtual SAN (VSAN), or all network traffic. Round trip response times, SCSI I/Os per second, SCSI read vs. write traffic throughput and frame counts, SCSI session status and management task information are provided. Additional statistics are also available on Fibre Channel frame sizes and network management protocols.
    For further information click this link.
    http://www.cisco.com/en/US/products/hw/ps4159/ps4358/products_data_sheet09186a0080142d34.html#wp1002317

  • Port-Channel issue between UCS FI and MDS 9222i switch

    Hi
    I have a problem between UCS FI and MDS switch port-channel. When MDS-A is powered down the port-channel fails but UCS blade vHBA does not detect the failure of the port-chanel on UCS-FI and leaves the vHBA online. However, if there is no port-channel between FI-->MDS it works fine.
    UCS version   
    System version: 2.0(2q)
    FI - Cisco UCS 6248 Series Fabric Interconnect ("O2 32X10GE/Modular Universal Platform Supervisor")
    Software
      BIOS:      version 3.5.0
      loader:    version N/A
      kickstart: version 5.0(3)N2(2.02q)
      system:    version 5.0(3)N2(2.02q)
      power-seq: Module 1: version v1.0
                 Module 3: version v2.0
      uC:        version v1.2.0.1
      SFP uC:    Module 1: v1.0.0.0
    MDS 9222i
    Software
      BIOS:      version 1.0.19
      loader:    version N/A
      kickstart: version 5.0(8)
      system:    version 5.0(8)
    Here is the config from MDS switch
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/1      103    auto   on      trunking         swl    TF      4    10
    fc1/2      103    auto   on      trunking         swl    TF      4    10
    fc1/9      103    auto   on      trunking         swl    TF      4    10
    fc1/10     103    auto   on      trunking         swl    TF      4    10
    This is from FI.
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/29     103    NP     on      trunking         swl    TNP     4    103
    fc1/30     103    NP     on      trunking         swl    TNP     4    103
    fc1/31     103    NP     on      trunking         swl    TNP     4    103
    fc1/32     103    NP     on      trunking         swl    TNP     4    103
    Any thoughts on this?

    Sultan,
    This is a recently found issue and is fixed in UCSM 2.0.3a version .
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCua88227
    which got duped to  CSCtz21585
    It happens only when following conditions are met
    FI in End host mode
    FC uplinks are configured for portchannel + trunking
    Certain link event failures ( such abrupt power loss by upstream MDS switch )
    Padma

  • ISCSI-to-FC routing in Cisco MDS 9000 Family

    Hi,
    I'm puzzled about support for iSCSI-to-FC routing in the MDS 9000 family. Earlier hardware such as the 9216i switch and the MPS-14/2 module had a feature to allow an iSCSI Initiator to connect transparently to an FC target. This equipment is now EOL and has been replaced by models such as the 9222i switch and the 18/4 Port Multiservice Module. The datasheets for these replacements strongly imply that they support iSCSI-to-FC routing in a similar way to the earlier products - for example "iSCSI for extension of the SAN to Ethernet attached servers - Extends the benefits of Fibre Channel SAN-based storage to Ethernet attached servers".
    I tried to find some hard technical info to confirm this. Chapter 4, "Configuring iSCSI" in "Cisco MDS 9000 Family NX-OS IP Services Configuration Guide Release 5.0(1a)" says that the feature is only available on the IP Storage Module, the 9216i switch, and the MPS-14/2 module, all of which are now EOL. It doesn't mention the replacement models in connection with this functionality, though they are mentioned elsewhere in the book for other features such as FC over IP. I've searched for documentation of the iSCSI support on the new models and the only document which seems relevant is this chapter - but it says it doesn't apply to these models.
    Do the replacement models support iSCSI-to-FC routing or not? The datasheets use wording nearly identical to the earlier models in this area, so I assume they do. If they do, how is it configured and where is it documented? I sent feedback on this to the documentation feedback address a while ago, but haven't had a reply.
    Many Thanks,
                                jjf

    The "Configuring iSCSI" chapter in both 3.3.3 and 4.1.1 documentation similarly talk about IPS and 14/2 modules but make no mention of 18/4, however I've used iSCSI on the 18/4 with both releases. I can only guess the same is true for 5.0 since I have yet to load 5.0 on any switches.
    In terms of other documentation I don't think there is any, but all the required information is presented in the "Configuring iSCSI" chapters however it's not the easiest thing to understand from the documentation. Following is the overview I sent to a teammate on how to setup iSCSI.
    1. configure Ethernet ports with ip addresses
      1a. add a route to the host, iSCSI client, via the gigabit interface 2. enable iscsi on the switch
      2a. enable iscsi on the module with the gige port
      2b. 'no shut' the iscsi interface corresponding to gige port
          e.g. gige3/4 -> iscsi3/4
      2c. no additional configuration of the interfaces is needed, although at some point turning on authentication would be a good idea
    3. create iscsi initiator
      3a. use the clients ip address as the initiator name, using the node name would be better but I haven't tried it that way so ymmv
          e.g. 'iscsi initiator ip-address xxx.xxx.xxx.xxx'
      3b. use a "system assigned" nwwn and set it static
          e.g. 'static pWWN system-assign'
      3c. allocate one "system assigned" pwwn and set it static
          e.g. 'static pWWN system-assign 1'
      3d. assign vsans, an iscsi initiator can be in more than one vsan
          e.g. 'vsan xxx'
    4. create targets
       spcsw1(config)# iscsi virtual-target name iqn.000190300646.fa02cb
       spcsw1(config-iscsi-tgt)# pwwn 50:06:04:8a:d5:f0:79:a1
       spcsw1(config-iscsi-tgt)# initiator ip address xx.xx.xx.xx permit
    5. zone the iscsi initiator's pwwn to the target pwwns, use 'sh iscsi initiator configured' to see the pwwn
    6. configure the hosts iscsi initiator, usually not much more than specifying the ip address of the gige port on the MDS

  • Cisco MDS 9418 switch doubt

    Hi Team,
    We have an issue, whether the cisco MDS 9418 switch supports FCIP feature.
    We are planning to migrate the data from our old data center over WAN to the EMC VNX storage box in other location.
    In our old data center we have 2 FC cisco switches connected to the EMC clariion storage array. Inorder to replicate data from clariion box to EMC VNX box over WAN ,it can be done via FCIP.
    I wanted to know if we can use insert the FCIP converters into these MDS 9418 switch or do we need to have separate FCIP converters.
    Do we need FCIP converters on both sides for doing replication over FCIP.
    For clear understanding please see the attachment.
    Will waiting for your response......
    Regards,
    Pranav.

    Hi,
    Since the 9148 does not have IP interfaces, something will be needed to tunnel the FC into IP (FCIP) such as an MDS 9222i, which has both FC interfaces and GigE interfaces and supports FCIP.
    Regards,
    David

  • Fabric Interconnect To MDS 9148 FC Port Channel/Trunks

    Is it possible to create both a Port Channel and Trunk on a Cisco MDS 9148? Yes correct?
    Or can I only trunk between the 2 MDS switches and not the MDS to Fabric Interconnect?
    These FC links would be connected to a 2248XP Fabric Interconnect carrying multiple VSANs from the MDS to the Fabric Interconnect.
    Thanks

    Hello,
    Yes, you can have trunk links grouped into port channel ( F port-channel trunking ) between FI and MDS.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html
    Padma

  • Shoul I upgrade MDS 9222i and MDS 9124 both have SANOS 3.3.2 to 3.3.5?

    Hi guys,
    I have 2 MDS 9222i, 2 MDS 9124 and 10 MDS Blades Switches (IBM Blades) all have SANOS 3.3.2.
    All those swicthes are attached to external drives (IBM DS4800) IBM requested to upgrade this DS4800 firmware level but in order to do that they told me that I need a new SANOS I plan to upgrade it to SANOS 3.3.5 can someone tell me if this SANOS works alright? or What SANOS do yoy recommend me?
    Thanks in advance

    The Cisco TAC will always defer to your Original Storage provided when asked which
    image to run, as they (the Original Storage providers) qualify our images for use with their
    devices.
    Regards,
    Ken

  • Configuring MDS 9222i and portchannels

    Trying to wrap my head around how a MDS 9222i is configured.  We have 2 of them and will be implementing FCIP.  I found a great document on FCIP and all of that and feel comfortable there.  However, connecting the MDS 9222i slightly confuses me.  I am assuming I can use all 4 of the 1Gbps copper ports.  Is this a correct assumption?  Can I use a portchannel/etherchannel configuration for this on the MDS?
    Any help would surely be appreciated.  Thank you.

    Ok, you guys were on the right track but anyone else who comes across this issue there are some things that were not clearly noted (or maybe I read over them) posted here:
    http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/cli_4_1/clibook.html
    Basically, MGMT port is required to get access to the device.  From there, I set up the gig ports which require separate IPs for each one that I want to uplink and for each FCIP configuration.
    interface GigabitEthernet1/1
      ip address 10.123.10.201 255.255.255.0
      switchport description Core Link connection
      no shutdown
    interface GigabitEthernet1/2
      ip address 10.123.10.202 255.255.255.0
      switchport description Core Link connection
      no shutdown
    interface GigabitEthernet1/3
      no shutdown
    interface GigabitEthernet1/4
      no shutdown
    interface mgmt0
      ip address 10.111.2.200 255.255.0.0
    From there, had to configure the FCIP connection:
    fcip profile 1
      ip address 10.123.10.201
      tcp max-bandwidth-mbps 30 min-available-bandwidth-mbps 20  round-trip-time-ms 5
    fcip profile 2
      ip address 10.123.10.202
      tcp max-bandwidth-mbps 30 min-available-bandwidth-mbps 20  round-trip-time-ms 5
    interface fcip1
      use-profile 1
      peer-info ipaddr 10.198.10.201
      channel-group 1 force
      no shutdown
    interface fcip2
      use-profile 2
      peer-info ipaddr 10.198.10.202
      channel-group 1 force
      no shutdown
    Thats really it.  The default gateway needed to be on the same subnet/VLAN as the Gigabit interfaces NOT the mgmt interface.  Found that out the hard way but that wasnt a big deal to figure out.
    From there, do the following command:
    sho fcip sum
    Tun prof    Eth-if    peer-ip       Status T W T Enc Comp  Bandwidth   rtt
                                               E A A            max/min    (us)
    1   1    GE1/1      10.198.10.201    TRNK  Y N N  N   N       30M/20M  5000
    2   2    GE1/2      10.198.10.202    TRNK  Y N N  N   N       30M/20M  5000
    But that was it.  Thanks for the help.

  • Cisco MDS 9513/9509 LDAP/AD Auth via SSH & Fabric Manager

    Hello Folks,
    I am trying to look for working config with LDAP auth over SSH. I know how to use them over TACACS+ & Radius. But due to other internal issue, currently I am trying to get the Cisco MDS to directly auth using LDAP/AD. Also, I see no option of LDAP/AD in FM(Fabric Manager), but just TACACS+, Radius, LocalFM and MDS. Do using MDS uses default auth(ie whatever AAA authentication is configured for ? or local DB on the switch).  Does the new DCNM supports LDAP/AD auth on the GUI ?
    Larger goal is SSH(CLI) & FM(GUI) using the same LDAP/AD auth. I understand the snmp-server user issue. But once I have SSH working over LDAP/AD I can figure that out to..
    Here's what I need to ensure when using LDAP/AD auth
    1) What is the exact config for this LDAP/AD auth
    2) How do I ensure that network-admin & network-opertor roles are assigned when certain AD Groups Logins in Like ADMIN-AD-GROUP , OPERATOR-AD-GROUP --> trying to login to the switch
    3) Also using SSL port for LDAP, do details are encrypted over the network.
    4) Do I need to use the PASSWORD in paintext when BINDING the BaseDN ?, can it be an encrypted password.
    Appreciate any info on this. Thanks for your time.

    As of DCNM 6.1 (aka - Fabric Manager Server) we support LDAP authentication adding to existing Radius, TACACS+, local and switch authentications.  You can upgrade from Fabric Manager 5.0 to DCNM 5.2 to DCNM 6.1 if you like to keep current performance, events, config data alive.  We do recommend fresh install as we don't know what state your server dabatabase might be in.  Including some links for you to help out with deployment and best practices (see release notes).
    Resources:
    Main Website:
    http://www.cisco.com/go/dcnm
    How To Video Series:  http://www.cisco.com/en/US/prod/netmgtsw/ps6505/ps9369/cisco_dc_nm_video_library.html
    Install and Licensing Guide:
    http://www.cisco.com/en/US/products/ps9369/prod_installation_guides_list.html
    Evaluation Licenses: http://tools.cisco.com/SWIFT/LicensingUI/Home?FormId=65
    Download Linux and Windows Executables: http://www.cisco.com/cisco/pub/software/portal/select.html?&i=!m&mdfid=281722751
    Data Sheets: http://www.cisco.com/en/US/prod/collateral/netmgtsw/ps6505/ps9369/data_sheet_c78-639737.html
    Install Guide: http://www.cisco.com/en/US/products/ps9369/prod_installation_guides_list.html
    Configure Guide:  http://www.cisco.com/en/US/products/ps9369/products_installation_and_configuration_guides_list.html
    API Programming Guide:
    http://www.cisco.com/en/US/products/ps9369/products_programming_reference_guides_list.html
    Reference Guide: http://www.cisco.com/en/US/products/ps9369/prod_technical_reference_list.html
    Release Notes: http://www.cisco.com/en/US/products/ps9369/tsd_products_support_general_information.html

  • Enabling NPIV in CISCO MDS 9500 Series

                       Hello!!!
    If i could get the response for my query.
    I need to enable NPIV as we have VM's to be created and allocate SAN storage to them so my CISCO MDS needs to have NPIV enabled. Following queries linked with this:
    1. Can i enabled NPIV on single Fibre Channel Port or it gets enabled on the complete SAN Switch
    2. Does enabling NPIV impact any other SAN operation. Also my 2- sites are connected via ISL, so is it important to enable NPIV across all my sites or i can enable it only at 1 site where my VM hosts are located.
    3. Any reference document for NPIV and related zoning concept.
    Thanks in advance.
    Faizul Mufti
    9958766711

    Hi,
    1. Can i enabled NPIV on single Fibre Channel Port or it gets enabled on the complete SAN Switch
    whole switch
    feature npiv
    2. Does enabling NPIV impact any other SAN operation. Also my 2- sites are connected via ISL, so is it important to enable NPIV across all my sites or i can enable it only at 1 site where my VM hosts are located.
    Will not impact any other SAN operation.  Non-disruptive.
    "feature npiv" is local to the switch, not fabric wide.  Use this command on any switch you want multiple flogi's on a single interface.
    3. Any reference document for NPIV and related zoning concept.
    I suggest zoning by pwwn
    Regards,
    David

  • Cisco MDS 9148 Inventory Collection

    Hi
    I get the following error on an inventory collection of a MDS 9148 (NOS 5.0.4). I have tried deleting and recreating the device.
    RME 4.3.1
    RICS0001:Internal Error,unable to process the collected data from the device.
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.LibInventory.PortInterfaceAGI_RFC1213_HelperMethods,getIfTableEntriesFromDevice,759,Entry speed after if block: 1000000000 Index value : 101191680
    [ Thu Dec 30  13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,58,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:populating AssetAG attributes, begins...
    [ Thu Dec 30  13:48:53 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,57,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,64,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:AssetAG Collection aborted com.cisco.nm.xms.xdi.ags.system.CollectionFailedDeviceSensed: java.lang.ArrayIndexOutOfBoundsException: 5 >= 5
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,549,DP time is 20 seconds for 172.23.32.129
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor,458,
    java.lang.NullPointerException
    at com.cisco.nm.rmeng.inventory.ics.invdata.containment.ContainmentAGInvData.compare(ContainmentAGInvData.java:103)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processContainmentAG(InvDataProcessor.java:864)
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:330)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,935, Exception occured in process method while processing: 172.23.32.129 null
    ICSException
    at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:473)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
    at java.lang.Thread.run(Thread.java:595)
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1191,No Trap
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1203,CALLING SELF TEST
    [ Thu Dec 30  13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1207,DONE WITH SELF TEST

    Hi Naem,
    have just read the othre reply's, the intresting bit it is in the MDF.
    - <DEVICE NAME="Cisco  MDS 9148 Multilayer Fabric Switch" MDFID="282867260" CISCOMDFID="282867260">
    <SYSOID OID="1.3.6.1.4.1.9.12.3.1.3.841" NAME="OID:1.3.6.1.4.1.9.12.3.1.3.841" />
    The device adds ok, I just can not run an Inventory but can run a backup !
    Thanks

Maybe you are looking for

  • Please help. 3 beeps and gray file on startup

    2012 Macbook Pro 13 inch. A friend brought it to me because of a white screen and gray flashing folder on startup. I booted to disk uility and saw that it did not see a hard drive. Pulled hard drive attached it with a external reader to my macbook. w

  • Script to insert an existing Rich symbol throws error

    I have an existing Rich Symbol called RSymbol. Now I write a script to place RSymbol into a certain layer which create. The problem is, that everytime i import a symbol like this with fw.getDocumentDOM().importFile(fw.appSymbolLibrariesDir+"RSymbol.g

  • Interesting SCOM Reports and "Microsoft System Center Virtual Machine Manager 2012 R2 Reports" MP Issue , Some reports appear others don't

    Our test environment is quite simple one Operations Server 2012 R2; with the database and SSRS instance on another server; Service Manager 2012 is on it's own virtual machine; and the Service Manager Data Warehouse on it's own. I've been trying to de