Interconnecting CIsco MDS 9222i to the HP C-Blade enclosute VC-FC Virtual connect module
Hi,
Anyone had the experience of interconnecting the CIsco MDS 9222i to an HP Blade system through the VC-FC virtual connect module?
When i connect my MDS switch to the module, the VC-FC ports dont log in to the MDS. Could i be missing out on something? I have configured the MDS to use the default VSAN 1 and tried configuring the ports as F-ports but nothing worked, even with the port mode put on auto they still take on the F-port role and still the VC-FC module doesnt log in.
Your help and support will be appreciated
jerrysimila
i wanna use the CLI though i also have the fabric manager at my disposal. would you kindly
share a sanitised version of ur running config for the mds that does the FCIP replication to the DR i see if i can make head out of it then i
f i face any challenge will holla at u. you can email me [email protected]
My set up is as follows, ive got 2 MDS 9222i at the primary site in active-standby mode, one connects to the active VC while the other connects to the standby VC of the blade system. Then i have a similar set up for the DR. Good thing is that am first setting everything up here in my Data Centre, then test before sending the configured equipment to the DR. So i have much freedom to get dirty with the equipment, and its not a live environment yet.
Kindly let me know the step-by-step procedure of having the FCIP set up.
Similar Messages
-
Cisco MDS 9222i 10G Module DS-X9704 supports FCoE
Hi, Whether Cisco MDS 9222i 10G Module DS-X9704 supports FCoE? i saw IP over FC in the data sheet of this module but not FCoE?
Thanks
AbhilashAlso whether this 10 G interface can work as an Ethernet port and not just a FiberChannel port?
-
How to factory default cisco MDS 9222i
How to factory default cisco MDS 9222i
Hi,
write erase
write erase boot
reload
(If prompted to save run to start, say no)
http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/cli_4_1/bb.html#wp1087208
Regards,
David -
need to know the license means which has been shown "Evaluation mode" in attached snap shot at Fabric Manager and its remedy.
any update on this
-
Connecting Fabric Interconnect with MDS
Dear Team,
Kindly share how to configure connectivity between Fabric Interconnect and MDS
what are the steps to be followed in establishing a successful connection between FI and MDS
We have a tape library from IBM and trying to connect the same to FI via MDS and want this Tape library to be detected on the guest VM running windows 2008 on Esxi( Service profile with 2 vhba already added),we are trying using Fibre connectivity.
Also please advice in which mode should we keep the FI (FC switching,end host etc)
Thanks and Regards
JoseHi Jose,
The common steps to configure FC on FI and MDS as following :
1. FI configured in NPV mode, ensure that all FC uplinks and vHBA of Blades have been assigned on correct VSAN
Verify if vHBA Flogi into the FI
show npv flogi-table
show npv status
Example
FI-A(nxos)# sh npv flogi-table
SERVER EXTERNAL
INTERFACE VSAN FCID PORT NAME NODE NAME INTERFACE
vfc703 10 0x330001 20:00:00:cc:1e:dc:01:0a 20:00:00:25:b5:00:00:03 San-po102
vfc711 10 0x330002 20:00:00:cc:1e:dc:02:0a 20:00:00:25:b5:00:00:02 San-po102
Total number of flogi = 2.
FI-A(nxos)# sh npv status
npiv is enabled
disruptive load balancing is disabled
External Interfaces:
====================
Interface: san-port-channel 102, State: Up
VSAN: 10, State: Up, FCID: 0x330000
Number of External Interfaces: 1
Server Interfaces:
==================
Interface: vfc703, VSAN: 10, State: Up
Interface: vfc711, VSAN: 10, State: Up
Number of Server Interfaces: 2
2. Enable NPIV mode on MDS, configure the link to FI as F port. Assign this port into correct VSAN
FI will become Node proxy, so verify if all vHBA have been detect on Upstream NPIV switch
SW2(config)# sh npiv status
NPIV is enabled
SW2(config)# sh flogi database
INTERFACE VSAN FCID PORT NAME NODE NAME
San-po102 10 0x330000 24:66:00:2a:6a:05:e9:00 20:0a:00:2a:6a:05:e9:01
San-po102 10 0x330001 20:00:00:cc:1e:dc:01:0a 20:00:00:25:b5:00:00:03
[BLADE1-SAN-A]
San-po102 10 0x330002 20:00:00:cc:1e:dc:02:0a 20:00:00:25:b5:00:00:02
[BLADE2-SAN-A]
3. Configure zoning on the MDS (to make sure whether the issue on zoning or not, you can configure the default zone to permit)
Example : zone default-zone permit vsan 1
Verify the zoning on Upstream NPIV switch
SW2(config)# SH ZONESet active vsan 10
zoneset name ZONESET-VSAN10 vsan 10
zone name INE-VSAN10 vsan 10
* fcid 0x330001 [device-alias BLADE1-SAN-A]
* fcid 0x330002 [device-alias BLADE2-SAN-A]
* fcid 0x2a0000 [device-alias FC-SAN10]
4. Ensure that vHBA of BLADE had been discovered on the storage device. Configure LUN masking on the storage
I really don't have enough knowledge of VMware hahaha.....so can't help for troubleshooting the VM....Really sorry
Thanks,
Gofi -
The Cisco MDS 9000 Port Analyzer Adapter
Hi,
At my client place, we are having an issue with BackUp via TSM and a library.
We would like to analyse the traffic that pass in the Fiber Channel of our MDS-9513.
From what we saw, Wireshark, our soft to analyse network traffic is only using NIC card to analyse.
Is the only way to analyse the FC traffic to pass via "The Cisco MDS 9000 Port Analyzer Adapter" ?
If that is the only way, is there a way tor ent this equipment for the time necesery to analyse our trace ?
Thank you in advance for you help.
Christian CarrierThe Cisco Traffic Analyzer provides real-time analysis of SPAN traffic or analysis of captured traffic through a Web browser user interface. Traffic encapsulated by one or more Port Analyzer Adapters can be analyzed concurrently with a single PC and ntop, which is public domain software enhanced by Cisco for Fibre Channel traffic analysis. This Cisco Traffic Analyzer solution enables you to quickly determine the throughput for traffic between specific Fibre Channel sources and destinations, all traffic in a particular Virtual SAN (VSAN), or all network traffic. Round trip response times, SCSI I/Os per second, SCSI read vs. write traffic throughput and frame counts, SCSI session status and management task information are provided. Additional statistics are also available on Fibre Channel frame sizes and network management protocols.
For further information click this link.
http://www.cisco.com/en/US/products/hw/ps4159/ps4358/products_data_sheet09186a0080142d34.html#wp1002317 -
Port-Channel issue between UCS FI and MDS 9222i switch
Hi
I have a problem between UCS FI and MDS switch port-channel. When MDS-A is powered down the port-channel fails but UCS blade vHBA does not detect the failure of the port-chanel on UCS-FI and leaves the vHBA online. However, if there is no port-channel between FI-->MDS it works fine.
UCS version
System version: 2.0(2q)
FI - Cisco UCS 6248 Series Fabric Interconnect ("O2 32X10GE/Modular Universal Platform Supervisor")
Software
BIOS: version 3.5.0
loader: version N/A
kickstart: version 5.0(3)N2(2.02q)
system: version 5.0(3)N2(2.02q)
power-seq: Module 1: version v1.0
Module 3: version v2.0
uC: version v1.2.0.1
SFP uC: Module 1: v1.0.0.0
MDS 9222i
Software
BIOS: version 1.0.19
loader: version N/A
kickstart: version 5.0(8)
system: version 5.0(8)
Here is the config from MDS switch
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
Mode (Gbps)
fc1/1 103 auto on trunking swl TF 4 10
fc1/2 103 auto on trunking swl TF 4 10
fc1/9 103 auto on trunking swl TF 4 10
fc1/10 103 auto on trunking swl TF 4 10
This is from FI.
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
Mode (Gbps)
fc1/29 103 NP on trunking swl TNP 4 103
fc1/30 103 NP on trunking swl TNP 4 103
fc1/31 103 NP on trunking swl TNP 4 103
fc1/32 103 NP on trunking swl TNP 4 103
Any thoughts on this?Sultan,
This is a recently found issue and is fixed in UCSM 2.0.3a version .
http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCua88227
which got duped to CSCtz21585
It happens only when following conditions are met
FI in End host mode
FC uplinks are configured for portchannel + trunking
Certain link event failures ( such abrupt power loss by upstream MDS switch )
Padma -
ISCSI-to-FC routing in Cisco MDS 9000 Family
Hi,
I'm puzzled about support for iSCSI-to-FC routing in the MDS 9000 family. Earlier hardware such as the 9216i switch and the MPS-14/2 module had a feature to allow an iSCSI Initiator to connect transparently to an FC target. This equipment is now EOL and has been replaced by models such as the 9222i switch and the 18/4 Port Multiservice Module. The datasheets for these replacements strongly imply that they support iSCSI-to-FC routing in a similar way to the earlier products - for example "iSCSI for extension of the SAN to Ethernet attached servers - Extends the benefits of Fibre Channel SAN-based storage to Ethernet attached servers".
I tried to find some hard technical info to confirm this. Chapter 4, "Configuring iSCSI" in "Cisco MDS 9000 Family NX-OS IP Services Configuration Guide Release 5.0(1a)" says that the feature is only available on the IP Storage Module, the 9216i switch, and the MPS-14/2 module, all of which are now EOL. It doesn't mention the replacement models in connection with this functionality, though they are mentioned elsewhere in the book for other features such as FC over IP. I've searched for documentation of the iSCSI support on the new models and the only document which seems relevant is this chapter - but it says it doesn't apply to these models.
Do the replacement models support iSCSI-to-FC routing or not? The datasheets use wording nearly identical to the earlier models in this area, so I assume they do. If they do, how is it configured and where is it documented? I sent feedback on this to the documentation feedback address a while ago, but haven't had a reply.
Many Thanks,
jjfThe "Configuring iSCSI" chapter in both 3.3.3 and 4.1.1 documentation similarly talk about IPS and 14/2 modules but make no mention of 18/4, however I've used iSCSI on the 18/4 with both releases. I can only guess the same is true for 5.0 since I have yet to load 5.0 on any switches.
In terms of other documentation I don't think there is any, but all the required information is presented in the "Configuring iSCSI" chapters however it's not the easiest thing to understand from the documentation. Following is the overview I sent to a teammate on how to setup iSCSI.
1. configure Ethernet ports with ip addresses
1a. add a route to the host, iSCSI client, via the gigabit interface 2. enable iscsi on the switch
2a. enable iscsi on the module with the gige port
2b. 'no shut' the iscsi interface corresponding to gige port
e.g. gige3/4 -> iscsi3/4
2c. no additional configuration of the interfaces is needed, although at some point turning on authentication would be a good idea
3. create iscsi initiator
3a. use the clients ip address as the initiator name, using the node name would be better but I haven't tried it that way so ymmv
e.g. 'iscsi initiator ip-address xxx.xxx.xxx.xxx'
3b. use a "system assigned" nwwn and set it static
e.g. 'static pWWN system-assign'
3c. allocate one "system assigned" pwwn and set it static
e.g. 'static pWWN system-assign 1'
3d. assign vsans, an iscsi initiator can be in more than one vsan
e.g. 'vsan xxx'
4. create targets
spcsw1(config)# iscsi virtual-target name iqn.000190300646.fa02cb
spcsw1(config-iscsi-tgt)# pwwn 50:06:04:8a:d5:f0:79:a1
spcsw1(config-iscsi-tgt)# initiator ip address xx.xx.xx.xx permit
5. zone the iscsi initiator's pwwn to the target pwwns, use 'sh iscsi initiator configured' to see the pwwn
6. configure the hosts iscsi initiator, usually not much more than specifying the ip address of the gige port on the MDS -
Hi Team,
We have an issue, whether the cisco MDS 9418 switch supports FCIP feature.
We are planning to migrate the data from our old data center over WAN to the EMC VNX storage box in other location.
In our old data center we have 2 FC cisco switches connected to the EMC clariion storage array. Inorder to replicate data from clariion box to EMC VNX box over WAN ,it can be done via FCIP.
I wanted to know if we can use insert the FCIP converters into these MDS 9418 switch or do we need to have separate FCIP converters.
Do we need FCIP converters on both sides for doing replication over FCIP.
For clear understanding please see the attachment.
Will waiting for your response......
Regards,
Pranav.Hi,
Since the 9148 does not have IP interfaces, something will be needed to tunnel the FC into IP (FCIP) such as an MDS 9222i, which has both FC interfaces and GigE interfaces and supports FCIP.
Regards,
David -
Fabric Interconnect To MDS 9148 FC Port Channel/Trunks
Is it possible to create both a Port Channel and Trunk on a Cisco MDS 9148? Yes correct?
Or can I only trunk between the 2 MDS switches and not the MDS to Fabric Interconnect?
These FC links would be connected to a 2248XP Fabric Interconnect carrying multiple VSANs from the MDS to the Fabric Interconnect.
ThanksHello,
Yes, you can have trunk links grouped into port channel ( F port-channel trunking ) between FI and MDS.
http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html
Padma -
Hi guys,
I have 2 MDS 9222i, 2 MDS 9124 and 10 MDS Blades Switches (IBM Blades) all have SANOS 3.3.2.
All those swicthes are attached to external drives (IBM DS4800) IBM requested to upgrade this DS4800 firmware level but in order to do that they told me that I need a new SANOS I plan to upgrade it to SANOS 3.3.5 can someone tell me if this SANOS works alright? or What SANOS do yoy recommend me?
Thanks in advanceThe Cisco TAC will always defer to your Original Storage provided when asked which
image to run, as they (the Original Storage providers) qualify our images for use with their
devices.
Regards,
Ken -
Configuring MDS 9222i and portchannels
Trying to wrap my head around how a MDS 9222i is configured. We have 2 of them and will be implementing FCIP. I found a great document on FCIP and all of that and feel comfortable there. However, connecting the MDS 9222i slightly confuses me. I am assuming I can use all 4 of the 1Gbps copper ports. Is this a correct assumption? Can I use a portchannel/etherchannel configuration for this on the MDS?
Any help would surely be appreciated. Thank you.Ok, you guys were on the right track but anyone else who comes across this issue there are some things that were not clearly noted (or maybe I read over them) posted here:
http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/cli_4_1/clibook.html
Basically, MGMT port is required to get access to the device. From there, I set up the gig ports which require separate IPs for each one that I want to uplink and for each FCIP configuration.
interface GigabitEthernet1/1
ip address 10.123.10.201 255.255.255.0
switchport description Core Link connection
no shutdown
interface GigabitEthernet1/2
ip address 10.123.10.202 255.255.255.0
switchport description Core Link connection
no shutdown
interface GigabitEthernet1/3
no shutdown
interface GigabitEthernet1/4
no shutdown
interface mgmt0
ip address 10.111.2.200 255.255.0.0
From there, had to configure the FCIP connection:
fcip profile 1
ip address 10.123.10.201
tcp max-bandwidth-mbps 30 min-available-bandwidth-mbps 20 round-trip-time-ms 5
fcip profile 2
ip address 10.123.10.202
tcp max-bandwidth-mbps 30 min-available-bandwidth-mbps 20 round-trip-time-ms 5
interface fcip1
use-profile 1
peer-info ipaddr 10.198.10.201
channel-group 1 force
no shutdown
interface fcip2
use-profile 2
peer-info ipaddr 10.198.10.202
channel-group 1 force
no shutdown
Thats really it. The default gateway needed to be on the same subnet/VLAN as the Gigabit interfaces NOT the mgmt interface. Found that out the hard way but that wasnt a big deal to figure out.
From there, do the following command:
sho fcip sum
Tun prof Eth-if peer-ip Status T W T Enc Comp Bandwidth rtt
E A A max/min (us)
1 1 GE1/1 10.198.10.201 TRNK Y N N N N 30M/20M 5000
2 2 GE1/2 10.198.10.202 TRNK Y N N N N 30M/20M 5000
But that was it. Thanks for the help. -
Cisco MDS 9513/9509 LDAP/AD Auth via SSH & Fabric Manager
Hello Folks,
I am trying to look for working config with LDAP auth over SSH. I know how to use them over TACACS+ & Radius. But due to other internal issue, currently I am trying to get the Cisco MDS to directly auth using LDAP/AD. Also, I see no option of LDAP/AD in FM(Fabric Manager), but just TACACS+, Radius, LocalFM and MDS. Do using MDS uses default auth(ie whatever AAA authentication is configured for ? or local DB on the switch). Does the new DCNM supports LDAP/AD auth on the GUI ?
Larger goal is SSH(CLI) & FM(GUI) using the same LDAP/AD auth. I understand the snmp-server user issue. But once I have SSH working over LDAP/AD I can figure that out to..
Here's what I need to ensure when using LDAP/AD auth
1) What is the exact config for this LDAP/AD auth
2) How do I ensure that network-admin & network-opertor roles are assigned when certain AD Groups Logins in Like ADMIN-AD-GROUP , OPERATOR-AD-GROUP --> trying to login to the switch
3) Also using SSL port for LDAP, do details are encrypted over the network.
4) Do I need to use the PASSWORD in paintext when BINDING the BaseDN ?, can it be an encrypted password.
Appreciate any info on this. Thanks for your time.As of DCNM 6.1 (aka - Fabric Manager Server) we support LDAP authentication adding to existing Radius, TACACS+, local and switch authentications. You can upgrade from Fabric Manager 5.0 to DCNM 5.2 to DCNM 6.1 if you like to keep current performance, events, config data alive. We do recommend fresh install as we don't know what state your server dabatabase might be in. Including some links for you to help out with deployment and best practices (see release notes).
Resources:
Main Website:
http://www.cisco.com/go/dcnm
How To Video Series: http://www.cisco.com/en/US/prod/netmgtsw/ps6505/ps9369/cisco_dc_nm_video_library.html
Install and Licensing Guide:
http://www.cisco.com/en/US/products/ps9369/prod_installation_guides_list.html
Evaluation Licenses: http://tools.cisco.com/SWIFT/LicensingUI/Home?FormId=65
Download Linux and Windows Executables: http://www.cisco.com/cisco/pub/software/portal/select.html?&i=!m&mdfid=281722751
Data Sheets: http://www.cisco.com/en/US/prod/collateral/netmgtsw/ps6505/ps9369/data_sheet_c78-639737.html
Install Guide: http://www.cisco.com/en/US/products/ps9369/prod_installation_guides_list.html
Configure Guide: http://www.cisco.com/en/US/products/ps9369/products_installation_and_configuration_guides_list.html
API Programming Guide:
http://www.cisco.com/en/US/products/ps9369/products_programming_reference_guides_list.html
Reference Guide: http://www.cisco.com/en/US/products/ps9369/prod_technical_reference_list.html
Release Notes: http://www.cisco.com/en/US/products/ps9369/tsd_products_support_general_information.html -
Enabling NPIV in CISCO MDS 9500 Series
Hello!!!
If i could get the response for my query.
I need to enable NPIV as we have VM's to be created and allocate SAN storage to them so my CISCO MDS needs to have NPIV enabled. Following queries linked with this:
1. Can i enabled NPIV on single Fibre Channel Port or it gets enabled on the complete SAN Switch
2. Does enabling NPIV impact any other SAN operation. Also my 2- sites are connected via ISL, so is it important to enable NPIV across all my sites or i can enable it only at 1 site where my VM hosts are located.
3. Any reference document for NPIV and related zoning concept.
Thanks in advance.
Faizul Mufti
9958766711Hi,
1. Can i enabled NPIV on single Fibre Channel Port or it gets enabled on the complete SAN Switch
whole switch
feature npiv
2. Does enabling NPIV impact any other SAN operation. Also my 2- sites are connected via ISL, so is it important to enable NPIV across all my sites or i can enable it only at 1 site where my VM hosts are located.
Will not impact any other SAN operation. Non-disruptive.
"feature npiv" is local to the switch, not fabric wide. Use this command on any switch you want multiple flogi's on a single interface.
3. Any reference document for NPIV and related zoning concept.
I suggest zoning by pwwn
Regards,
David -
Cisco MDS 9148 Inventory Collection
Hi
I get the following error on an inventory collection of a MDS 9148 (NOS 5.0.4). I have tried deleting and recreating the device.
RME 4.3.1
RICS0001:Internal Error,unable to process the collected data from the device.
[ Thu Dec 30 13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.LibInventory.PortInterfaceAGI_RFC1213_HelperMethods,getIfTableEntriesFromDevice,759,Entry speed after if block: 1000000000 Index value : 101191680
[ Thu Dec 30 13:48:46 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,58,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:populating AssetAG attributes, begins...
[ Thu Dec 30 13:48:53 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.util.logger.XDILogger,57,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless.AssetAGI_CISCO_ENTITY_ASSET_Mib,g$eval,64,com.cisco.nm.xms.xdi.pkgs.SharedInventoryWireless:AssetAGI_CISCO_ENTITY_ASSET_MIB:g$eval:AssetAG Collection aborted com.cisco.nm.xms.xdi.ags.system.CollectionFailedDeviceSensed: java.lang.ArrayIndexOutOfBoundsException: 5 >= 5
[ Thu Dec 30 13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,549,DP time is 20 seconds for 172.23.32.129
[ Thu Dec 30 13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor,458,
java.lang.NullPointerException
at com.cisco.nm.rmeng.inventory.ics.invdata.containment.ContainmentAGInvData.compare(ContainmentAGInvData.java:103)
at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processContainmentAG(InvDataProcessor.java:864)
at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:330)
at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
at java.lang.Thread.run(Thread.java:595)
[ Thu Dec 30 13:48:55 GMT 2010 ],ERROR,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,935, Exception occured in process method while processing: 172.23.32.129 null
ICSException
at com.cisco.nm.rmeng.inventory.ics.server.InvDataProcessor.processInvData(InvDataProcessor.java:473)
at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:923)
at java.lang.Thread.run(Thread.java:595)
[ Thu Dec 30 13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1191,No Trap
[ Thu Dec 30 13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1203,CALLING SELF TEST
[ Thu Dec 30 13:48:55 GMT 2010 ],INFO ,[Thread-15],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,1207,DONE WITH SELF TESTHi Naem,
have just read the othre reply's, the intresting bit it is in the MDF.
- <DEVICE NAME="Cisco MDS 9148 Multilayer Fabric Switch" MDFID="282867260" CISCOMDFID="282867260">
<SYSOID OID="1.3.6.1.4.1.9.12.3.1.3.841" NAME="OID:1.3.6.1.4.1.9.12.3.1.3.841" />
The device adds ok, I just can not run an Inventory but can run a backup !
Thanks
Maybe you are looking for
-
Please help. 3 beeps and gray file on startup
2012 Macbook Pro 13 inch. A friend brought it to me because of a white screen and gray flashing folder on startup. I booted to disk uility and saw that it did not see a hard drive. Pulled hard drive attached it with a external reader to my macbook. w
-
Script to insert an existing Rich symbol throws error
I have an existing Rich Symbol called RSymbol. Now I write a script to place RSymbol into a certain layer which create. The problem is, that everytime i import a symbol like this with fw.getDocumentDOM().importFile(fw.appSymbolLibrariesDir+"RSymbol.g
-
Our test environment is quite simple one Operations Server 2012 R2; with the database and SSRS instance on another server; Service Manager 2012 is on it's own virtual machine; and the Service Manager Data Warehouse on it's own. I've been trying to de
-
I have a new iPad and when trying to restore from my iCloud account I get an error message "cannot restore because there is a problem with the backup data" I have tried new and old backups. Don't know what to try next? Any help welcome. Thanks
-
Sequence audio format stuck on 32-bit Floating Point
Hi, The audio format for all my sequences is set to 32-bit Floating Point when I check them in the browser's Aud Format field. When I manually change the format in the sequence settings nothing changes in the browser and choosing a new sequence set u