Interface connectivity ALE

We are setting up an interface between ERP and  decentralised WMS system..
Both the systems are SAP systems but belong to two different companys'
what kind of interface will be suitable for this...
I meant will ALE/BAPI interface be sufficient...?
What kind of connectivity needed...VPN..Landline...?
Where can i find docs related to this...
I have Le-IDW docs is there any other links available...?
Thanks
Larry

Hi,
  Check these links
ALE/ IDOC
http://help.sap.com/saphelp_erp2004/helpdata/en/dc/6b835943d711d1893e0000e8323c4f/content.htm
http://www.sapgenie.com/sapgenie/docs/ale_scenario_development_procedure.doc
http://edocs.bea.com/elink/adapter/r3/userhtm/ale.htm#1008419
http://www.netweaverguru.com/EDI/HTML/IDocBook.htm
http://www.sapgenie.com/sapedi/index.htm
http://www.sappoint.com/abap/ale.pdf
http://www.sappoint.com/abap/ale2.pdf
http://www.sapgenie.com/sapedi/idoc_abap.htm
http://help.sap.com/saphelp_erp2005/helpdata/en/0b/2a60bb507d11d18ee90000e8366fc2/frameset.htm
http://help.sap.com/saphelp_erp2005/helpdata/en/78/217da751ce11d189570000e829fbbd/frameset.htm
http://www.allsaplinks.com/idoc_sample.html
http://www.sappoint.com/abap.html
http://help.sap.com/saphelp_erp2004/helpdata/en/dc/6b835943d711d1893e0000e8323c4f/content.htm
http://www.sapgenie.com/sapgenie/docs/ale_scenario_development_procedure.doc
http://edocs.bea.com/elink/adapter/r3/userhtm/ale.htm#1008419
http://www.netweaverguru.com/EDI/HTML/IDocBook.htm
http://www.sapgenie.com/sapedi/index.htm
http://www.allsaplinks.com/idoc_sample.html
ALE/ IDOC/ XML
http://www.sapgenie.com/sapgenie/docs/ale_scenario_development_procedure.doc
http://www.thespot4sap.com/Articles/SAP_XML_Business_Integration.asp
http://help.sap.com/saphelp_srm30/helpdata/en/72/0fe1385bed2815e10000000a114084/content.htm
IDOC Convertion
/people/kevin.wilson2/blog/2005/12/07/changing-fields-in-an-idoc-segment

Similar Messages

  • The interface connecting Lean-WM and inventory management

    Dear experts!
    Thank you for your attention!
    I am confused at the interface connecting Lean-WM and inventory management.
    there are so many concepts in this field, such storage location, picking areas, storage types and so on.
    Could you please give me an real case or a illustration to discribe that how the interface connecting Lean-WM and inventory management works?
    Best regard!
    Tangdark

    you do nto need to enter serial numbers while clearing inventory at WM level but at IM in case you have the serial profile activated then you need to enter serial numbers when clearing inventory from the IM level.
    according to what you have said it should automatically pop up a screen where you need o enter the serial numbers but this is weird it is not doing.
    Please check the following:-
    Does the serial number profile config in OIS2 have "MMSL" as a property and if so is entry of serial numbers mandatory during goods receipt and issue ad if there is a stock check active

  • Mailbox Move Not Complete - Unable to make admin interface connection to server.

    Hello,
    I have added a second exchange 2007 server and have moved over 20 mailboxes to the new server. I seem to have a problem that the mailbox move has not been completed properly. I'm getting errors in the event log that the search indexer cannot connect to the
    admin interface. I'm also unable to login as any one of the users who I've moved to the new server.
    Here's one of the errors I'm getting:
    Exchange Search Indexer has temporarily disabled indexing of the Mailbox Database Third Storage Group\Mailbox Database 03 (GUID = d4f3ee4d-68b0-4d21-8a76-ee96bf298f34) due to an error (Microsoft.Mapi.MapiExceptionNetworkError: MapiExceptionNetworkError:
    Unable to make admin interface connection to server. (hr=0x80040115, ec=-2147221227)
    Diagnostic context:
        Lid: 10648   dwParam: 0x6D9      Msg: EEInfo: Generating component: 2
        Lid: 14744   dwParam: 0x6D9      Msg: EEInfo: Status: 1753
        Lid: 9624    dwParam: 0x6D9      Msg: EEInfo: Detection location: 501
        Lid: 13720   dwParam: 0x6D9      Msg: EEInfo: Flags: 0
        Lid: 11672   dwParam: 0x6D9      Msg: EEInfo: NumberOfParameters: 4
        Lid: 8856    dwParam: 0x6D9      Msg: EEInfo: prm[0]: Unicode string: ncacn_ip_tcp
        Lid: 8856    dwParam: 0x6D9      Msg: EEInfo: prm[1]: Unicode string: EP-SW-EX04
        Lid: 12952   dwParam: 0x6D9      Msg: EEInfo: prm[2]: Long val: -1988875570
        Lid: 12952   dwParam: 0x6D9      Msg: EEInfo: prm[3]: Long val: 382312662
        Lid: 24060   StoreEc: 0x80040115
        Lid: 23746 
        Lid: 31938   StoreEc: 0x80040115
        Lid: 19650 
        Lid: 27842   StoreEc: 0x80040115
        Lid: 20866 
        Lid: 29058   StoreEc: 0x80040115
       at Microsoft.Mapi.MapiExceptionHelper.ThrowIfError(String message, Int32 hresult, Int32 ec, DiagnosticContext diagCtx)
       at Microsoft.Mapi.ExRpcAdmin.Create(String server, String user, String domain, String password)
       at Microsoft.Exchange.Search.NotificationWatcher.NotificationWatcherThread()).

    Hello,
    I have been fighting today with the migration off my old SBS2003 server to a brand new SBS2008 server. I have been preparing this migration for a couple off weeks
    now (watching videos, reading migration manual from Microsoft, searching TechNet, etc.)
    After some troubles with installing the server in Migration mode if finally came to the part to move my old (legacy) mailboxes to the new SBS2008 server. At this point the drama started  @#$@$#&^%%#$@
    I followed the manual off Microsoft which descripted how to move these mailboxes.
    Exchange displayed a error message :
    MapiExceptionNetworkError: Unable to make admin interface connection to server. (hr=0x80040115, ec=-2147221227)
    When I googled this error message I realized that many people encountered the same problem but no one had the right answer to this question. I have searched hours and hours to find a solution. It started to drive me crazy and to make it even more worse i discovered
    that even though i completed the first step in the migration proces (update the schema to allow a SBS2008 DC to join the domain) my replication with the other DC controllers came with a schema mismatch error???? WTF is going on !!!!!!!!
    Finally a brilliant college off me came with the answer that solved all my problems: To GET RID OFF THIS ERROR MESSAGE INSTALL: Messaging API and Collabration Data Objects 1.2.1  on the Exchange server.
    After moving about 60 mailboxes my blood pressure dropped and became stable again.
    I Have on finall question WHY Microsoft?  Was this to much trouble to put this in het migration manual off 81 pages?
    from-a-very-disappointed-microsoft-user
    PLS: send me a reply if this solved you're problem moving the mailboxes to the new server. !

  • MapiExceptionNetworkError: Unable to make admin interface connection to server

    Receiving the following error trying to move mailboxes from Exchange 2003 to 2007 after installation. Verified all NIC's are configured. All Exchange processes are running as 'Local system'. Any other suggestions?
    MapiExceptionNetworkError: Unable to make admin interface connection to server. (hr=0x80040115, ec=-2147221227)
    Diagnostic context:......
        Lid: 10648   dwParam: 0x6D9      Msg: EEInfo: Generating component: 2
        Lid: 14744   dwParam: 0x6D9      Msg: EEInfo: Status: 1753
        Lid: 9624    dwParam: 0x6D9      Msg: EEInfo: Detection location: 501
        Lid: 13720   dwParam: 0x6D9      Msg: EEInfo: Flags: 0
        Lid: 11672   dwParam: 0x6D9      Msg: EEInfo: NumberOfParameters: 4
        Lid: 8856    dwParam: 0x6D9      Msg: EEInfo: prm[0]: Unicode string: ncacn_ip_tcp
        Lid: 8856    dwParam: 0x6D9      Msg: EEInfo: prm[1]: Unicode string: vienna1.cvesd.org
        Lid: 12952   dwParam: 0x6D9      Msg: EEInfo: prm[2]: Long val: -1988875570
        Lid: 15000   dwParam: 0x6D9      Msg: EEInfo: prm[3]: Pointer val: 0x0x04a4cef0 (UnknownPtag)
        Lid: 23746 
        Lid: 31938   StoreEc: 0x80040115
        Lid: 19650 
        Lid: 27842   StoreEc: 0x80040115
        Lid: 20866 
        Lid: 29058   StoreEc: 0x80040115
    Exchange Management Shell command attempted:
    'e3e40217-6649-43be-9feb-0c4e594cbcf1' | move-mailbox -BadItemLimit '10' -TargetDatabase 'CN=Mailbox Database,CN=First Storage Group,CN=InformationStore,

    I ran into the same problem during the migration from SBS 2003 Premium with ISA Server 2004 to SBS 2011 Standard, and that is how
    I found this thread.
    I have tried ALL of the proposed solutions but unfortunately nothing worked for me…
    Even though you paid proper attention to the migration path from SBS2003 to SBS2011 manual, followed all the steps, and performed
    the suggested step:
    To configure remote procedure call (RPC) filtering
    1.
    Click
    Start, click All Programs, click Microsoft ISA Server, and then click
    ISA Server Management.
    2.
    In the ISA Server Management Console tree, expand
    Microsoft Internet Security and Acceleration Server 2004, expand
    ServerName, and then click Firewall Policy.
    3.
    In the details pane, click the
    SBS Protected Networks Access Rule.
    4.
    On the
    Taskstab, click Edit Selected Rule.
    5.
    On the
    Protocolstab (for an access rule), click Filtering, and then click
    Configure RPC protocol.
    On the
    Protocols tab, clear the Enforce strict RPC compliance check box, and then click
    Apply.
    …you will still get the notorious
    MapiExceptionNetworkError: Unable to make connection to the server. (hr=0x80040115, ec=-2147221227) error.
    Here is the solution to the Small Business Server 2003 with ISA Server 2004 migrating to the next level scenario:
    *** Disable RPC Filter ***
    To disable remote procedure call (RPC) filter
    1.
    Click
    Start, click All Programs, click Microsoft ISA Server, and then click
    ISA Server Management.
    2.
    In the ISA Server Management Console tree, expand
    Microsoft Internet Security and Acceleration Server 2004, expand
    ServerName, expand Configuration, and then click
    Add-Ins.
    3.
    In the
    Application Filters pane, click the RPC Filter.
    4.
    On the
    Tasks tab, click Disable Selected Rule.
    To save changes and update the configuration, click
    Apply.
    I also opted to restart the service when prompted after hitting the “Apply” button.
    I hope this helps someone to keep whatever is left of his or her hair and lower the blood pressure a bit :)
    This was the solution also!!
    Thanks. My heart doctor says that now, ina few weeks i will be fine. and hope my hair grows again.. :)
    Thank you very much
    mpleite

  • Javax.jms: Interface Connection

    Hi all.
    In the above interface is said:
    "A Connection object is a client's active connection to its JMS provider. It typically allocates provider resources outside the Java virtual machine (JVM). "
    What does this part exactly mean?
    "It typically allocates provider resources outside the Java virtual machine (JVM)."
    Thanks in advance.

    Can you also help me on this please; I have this piece of code; factory is an object of type: progress.message.jclient.ConnectionFactory
    Then createConnection() returns an object of type: Connection: javax.jms Interface Connection
    But shouldn't Connection be a class and not an interface?
    Any help is greatly appreciated.
    public class Chat
        implements javax.jms.MessageListener
    private javax.jms.Connection connect = null;
        private javax.jms.Session pubSession = null;
        private javax.jms.Session subSession = null;
        private javax.jms.MessageProducer publisher = null;
        /** Create JMS client for publishing and subscribing to messages. */
        private void chatter( String broker, String username, String password)
            // Create a connection.
            try
    // factory is an object of type: progress.message.jclient.ConnectionFactory
    javax.jms.ConnectionFactory factory;
                factory = (new progress.message.jclient.ConnectionFactory (broker));
                connect = factory.createConnection (username, password);
                pubSession = connect.createSession(false,javax.jms.Session.AUTO_ACKNOWLEDGE);
                subSession = connect.createSession(false,javax.jms.Session.AUTO_ACKNOWLEDGE);
            catch (javax.jms.JMSException jmse)
                System.err.println("error: Cannot connect to Broker - " + broker);
                jmse.printStackTrace();
                System.exit(1);
    }

  • BMW 335i ipod interface connection problem with ipod classic 80GB

    Hi all, i have a 2007 BMW 335i with dealer installed ipod interface, and i been using it since, it's simply i just connect ipod with the cable in the glove compartment and leave it there, and it charges and stanby, when i start up the car the audio jumps right to where i left off on the ipod and it also let me control it with iDrive. after about one and half year of usage, i think there is something wrong with my ipod or i dont know for sure, well here is the problem, when i start the car it will play music from the ipod and i can control it from iDrive and everything but after about 5-10 mins, the music stop, and my iDrive shows weird playlist, and i need to unplug the ipod and replug again to have it connect and then it will stop by itself, after 5-10 mins, any of you guys have a bmw with the ipod interface have this problem?? i dont really know if it's my ipod problem or my bmw ipod interface problem. anyone can help me with this? thank you!

    That is most likely going to be a problem with your iPod, not the interface.
    Have you tried Resetting the iPod? (hold down the menu and center buttons for six seconds).
    If that fails to work, try Restoring the iPod in iTunes.

  • How to know interfaces connected to BI system

    Dear Experts,
    I want to know how many interfaces my BI SYSTEM in connected to.
    How can I find that.
    Thanks

    Have a look in your documentation, if your system interfaces are not documented, then something is wrong in your place... But on the other hand, you could check RSA1 for datasources, SM59 for remote connections or WE20 for connected logical systems. Be aware that severe damage can be caused be unknowingly changing things in these transactions!
    Good luck, Michael

  • Solaris 8: Multiple primary interfaces connected to the same network

    I have a machine with Solaris 8, and it has multiple interfaces that are connected to the same network which means they all have metric 0 (1 hop) to the default gateway.
    assume:
    e1000g0: 192.168.30.70
    e1000g2: 192.168.30.72
    e1000g4: 192.168.30.74
    e1000g5: 192.168.30.76
    gateway: 192.168.30.65 (Cisco Router)
    However, it seems like despite the fact that they have a direct connection, they seem to be using e1000g0 to access the 192.168.30.0 network to get to the default gateway and then to anywhere else.
    When I send a ping to say, 192.168.30.74 (IP of e1000g4) and capture packets on e1000g0, I see the "echo reply" messages going out of it as opposed to e1000g4 even though e1000g4 is the one receiving the "echo request". This should not happen and these should be completely independent as they should all be advertising a 1 hop to that network
    The outputs from netstat -rn and ifconfig -a are shown in the picture on the link below
    [http://img836.imageshack.us/img836/7308/ifconfignetstathiddenip.jpg]
    This gets even more confusing when I go into the Cisco router and run the command: "show mac address-table" where only the MAC address of e1000g0 is shown for the switch port it's connected to, but not for the other interfaces which are connected to the switch. Yes, all ports are active (no shut) and are pingable.
    Also, the odd thing is that ALL of these individual MACs show up in the router ARP table when the machine comes up, however after sending a ping to one of them, after a certain expiry or whatever period, the MACs disappear from the router ARP table and only the MAC for e1000g0 shows up. The arp table of the solaris machine however shows all the relevant MACs of each port of the router that it's physically connected to (This is actually a Cisco Switch with the advanced IP services imagine and L3 routing turned on)
    Before anyone asks: The setting local-mac-address? setting does NOT exist in my machine and it never has, but it used to work fine. Also, from the ifconfig command, once can tell that all the MAC addresses are fine.
    I need to somehow assign all these interfaces equal priority and make them understand that they're physically connected to the 192.168.30.0 network and there's no need to go through e1000g0 to get to it.
    This is causing a lot of problems as eventually all traffic will end up going through the e1000g0 interface and that will become a bottle neck.
    Please help Thanks in advance

    Ok thanks. That was a useful response.
    I did think about the trunking software that is claimed to be available for Solaris 8, but it's only available if you've got paid support contract. Oracle came and ruined everything re: Sun support which is so expensive now.
    The other confusion is, we never had that OR needed to configure trunking/link aggregation on this machine, so why now?
    Lastly, by your explanation, this should be expected and is "normal" behaviour, which would mean that this machine was always doing this and I only just noticed it this time? I thought if you turn off ipv4 forwarding and router function in the machine, it's every interface for itself. But it's not doing that :(
    So then the question is, Can I force it? I've tried a bunch of things by manipulating the tables and it seems to mess things up where nothing is getting through or it now shifts all the traffic to some other port make the problem no different
    Is there a way to give equal weight to all interfaces for the traffic to go directly through them that is originating at those ports?

  • Duplicate Ethernet Interface - Connection Issues

    Hi,
       Recently, after rebooting, I had a continuous stream of error messages on my login terminal, and I couldn't connect to the network.
    [ 669.236979] genirq: Flags mismatch irq 0. 00000080 (eth0) vs. 00015a20 (timer)
    [ 670.235840] genirq: Flags mismatch irq 0. 00000080 (eth0) vs. 00015a20 (timer)
    [ 671.234701] genirq: Flags mismatch irq 0. 00000080 (eth0) vs. 00015a20 (timer)
    # ping www.google.com
    ping: unknown host www.google.com
    # ip link
    1: lo: <LOOPBACK,UP,LOWER_UP> mtu 16436 qdisc noqueue state UNKNOWN mode DEFAULT
    link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
    2: eth0: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT qlen 1000
    link/ether de:34:07:d0:d9:29 brd ff:ff:ff:ff:ff:ff
    3: eth1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT qlen 1000 ## Duplicate interfaces?
    link/ether 00:24:1d:a2:f7:c5 brd ff:ff:ff:ff:ff:ff
    # ifconfig eth0 up
    SIOCSIFFLAGS: Device or resource busy
    # ifconfig eth1 up
    # dhcpcd eth1
    dhcpcd[732]: version 5.6.4 starting
    dhcpcd[732]: eth1: sending IPv6 Router Solicitation
    dhcpcd[732]: eth1: rebinding lease of 192.168.1.3
    dhcpcd[732]: eth1: acknowledged 192.168.1.3 from 192.168.1.1
    dhcpcd[732]: eth1: checking for 192.168.1.3
    dhcpcd[732]: eth1: sending IPv6 Router Solicitation
    dhcpcd[732]: eth1: leased 192.168.1.3 for 2592000 seconds
    dhcpcd[732]: forked to background, child pid 780
    # ping www.google.com
    64 bytes from bom03s02-in-f18.1e100.net (74.125.236.146): icmp_seq=1 ttl=56 time=11.6 ms
    After manually configuring eth1, and assigning it an IP, everything works normally. Another bunch of curious messages at boot up were these:
    [ 0.271521] pci 0000:01:07.0: BAR 1: error updating (0xfde00000 != 0x000000)
    [ 0.271553] pci 0000:01:07.0: BAR 3: error updating (0xfdf10008 != 0x000008)
    [ 0.271583] pci 0000:01:07.0: BAR 2: error updating (0x00c001 != 0x00cc09)
    What would be a clean way to fix this?
    Thanks in advance!

    Thanks for the replies.
    In an attempt to establish whether it was the computer or the router I plugged in an old speedtouch 510 router which I had lying around - this worked first time, so I guess it's the netgear that is the issue and I will need to reset it and re-enter all the details, unless anyone knows of a quicker way...?

  • Lion ui generally slow on macbook pro 5.1 -- gets worse w/ edirol fa-66 audio interface connected

    so, after doing a fresh install of os x lion (10.7.1) I'm having issues with the speed of the user interface. it is just really sluggish, especially when compared to the the performance I used to get with snow leopard (10.6.8). dock, animations of all kinds, even parsing through finder trees, everything seems to stutter at around 20-25fps instead of the super smoothness I used to get in SL.
    the funny thing is, it gets even worse when I hook up my firewire audio interface, the edirol fa-66. even when nothing is playing or being recorded, the UI
    gets slower still. also, the cpu-temperature goes up by some 12-15°C.
    the machine is a late 2008 15" macbook pro, 2.4GHz core 2 duo, 8GB ram, hybrid 7.2k/ssd drive (seagate momentus xt) w/ filevault2 full disk encryption on, and either the nvidia 9400m or 9600m gt graphics running.
    to quantify: on the venerable xbench 1.3 user interface test I'm getting a score of around 90 with either graphics chip, instead of the 280+ I got in (snow) leopard. with the fa-66 connected, the score drops to an even lower 80. open gl and xquartz scores go down a similar percentage with the fa-66 connected.
    so, is anybody out there having the same issues? ui just too slow? getting worse with the fa-66?
    any useful ideas?

    I have the same mac, except mine has a GeForce 8600M. I don't have any external audio devices but my computer has slowed down dramtically since I upgraded to lion, almost to the point where I can't use Aperture anymore. I didn't have any issues on snow leopard.

  • Regarding Interface connection with US Payroll Data

    Hi Experts,
    Greeting!
    I have some questions regarding Interface (ADP Tool) with USA payroll. Please give me the answer for below questions.
    1) How to send the data ( Garnishment, Benefits, Payroll, PA) to third party tool?.
    2) How to map the things (Wage types) and Which T.Code we use for this?.
    3) What all Technologies required to connect third party tool?.
    4) How will we get the data from third party?
    5) What all documents will create while sending and receiving the data?
    Thanks in Advance.
    Regards,
    Ram

    Hello Ram,
    The transaction for US Payroll outsourcing is PC00_M10_OTEM. I have attached a document to this reply that can be found as an attachment to SAP Note No. 1135822 - "OT:  Outsourcing FAQ Document". Outsourcing is similar to running payroll except the data is exported instead of being calculated.
    Also for reference:
    SAP Note No. 899674 - "FAQ:  First Export for Payroll Outsourcing Interface"
    Regards,
    Manny

  • Playing DVDs in 5.1 With Firewire Audio Interface Connected for Logic Pro

    This is exactly the same q as asked by plantwebguy in July 06, link
    http://discussions.apple.com/message.jspa?messageID=2696970#2696970...
    I'm struggling to get an answer on this anywhere... I have Logic Pro running 5.1 Surround Mixes on a g5, using a Metric Halo Mobile IO Firewire audio interface - its 6 analog outs are connected to a M Audio LX4 powered surround system. It all works great - until... the problem is when I need to listen to DVDs with 5.1 soundtracks (for reference), or even HD trailers (with 5.1 soundtracks). With the Mobile IO selected as audio interface, DVDs only play in stereo. I think this is because the 5.1 soundtrack is only output thru the optical out - but connecting the optical out to the Mobile IO and selecting 'Digital out' on the g5 brings silence.. Im told this is because the MIO's optical in wont decode 5.1. I'm interested to hear from anyone with a Pro Audio interface - like a MOTU etc - who needs to switch between mixing their own music in 5.1 and then listening to DVDs in 5.1.. I cant be the first, surely?
    Plantwebguy said he solved his issue with VLC. Do we know if VLC willl decode 5.1 and then output it to the Interface via Firewire? I've searched the net for a Pro Audio interface with (1) 6 analog outs & mic inputs etc (2) firewire connection and (3) optical in that reads AC3/5.1 etc (rather than just ADAT).... nada. Sorry to be long-winded but I cant get a solution anywhere..
    Thanks in advance
    g5 dual 2.5   Mac OS X (10.3.9)   Logic Pro/Mobile IO 2882 FW Interface/M Audio LX4

    This is exactly the same q as asked by plantwebguy in July 06, link
    http://discussions.apple.com/message.jspa?messageID=2696970#2696970...
    I'm struggling to get an answer on this anywhere... I have Logic Pro running 5.1 Surround Mixes on a g5, using a Metric Halo Mobile IO Firewire audio interface - its 6 analog outs are connected to a M Audio LX4 powered surround system. It all works great - until... the problem is when I need to listen to DVDs with 5.1 soundtracks (for reference), or even HD trailers (with 5.1 soundtracks). With the Mobile IO selected as audio interface, DVDs only play in stereo. I think this is because the 5.1 soundtrack is only output thru the optical out - but connecting the optical out to the Mobile IO and selecting 'Digital out' on the g5 brings silence.. Im told this is because the MIO's optical in wont decode 5.1. I'm interested to hear from anyone with a Pro Audio interface - like a MOTU etc - who needs to switch between mixing their own music in 5.1 and then listening to DVDs in 5.1.. I cant be the first, surely?
    Plantwebguy said he solved his issue with VLC. Do we know if VLC willl decode 5.1 and then output it to the Interface via Firewire? I've searched the net for a Pro Audio interface with (1) 6 analog outs & mic inputs etc (2) firewire connection and (3) optical in that reads AC3/5.1 etc (rather than just ADAT).... nada. Sorry to be long-winded but I cant get a solution anywhere..
    Thanks in advance
    g5 dual 2.5   Mac OS X (10.3.9)   Logic Pro/Mobile IO 2882 FW Interface/M Audio LX4

  • WLC 5508 Management Interface Connection

    I'm setting up a new 5508.  I've used the config from a 4402, have successfully connected to the Service port to manage the device, but for some reason cannot connect to the Management interface.  In this case, port 1.
    The service port is connected to a Catalyst switch and grabbed an ip address (10.2.x.x subnet) no problem.  I can access the 5508 via https using the SP.  However, port 1 is connected to the same Catalyst switch, but on a different vlan (subnet 10.20.x.x).  Both ends show that the interfaces are up, I can ping the interface from any other host on the network, but when I try to manage the device via https I cannot connect.  We are using WCS and I cannot add the device from the WCS.  About all I can do is ping that interface.
    I've probably overlooked something very basic, but I'm baffled.

    Thanks for the reply.
    No, definitely not that.  I have all of those enabled.  I have the SP connected to another vlan on the same switch and can manage through that port(https, telnet).  I've tried about every combination of trunk port, access port, etc.  I'm beginning to suspect the GBICs (10baseT), but both ends show that I am connected at 1000 and I can ping the ip address of the management interface.

  • External Interface Connection (EIC) not working in Mozilla but ok in IE

    I am using XCelcius 2008 SP5 and have proven that I can expose the methods provided in the EIC interface to write data out of the flash movie to a javascript function. This works only in Internet Explorer, but fails in recent versions of Mozilla Firefox. I use two different methods to obtain a reference to the flash object by the way; one for IE browsers; another for non IE browsers. I have run debugger in Firefox and cannot see the EIC methods exposed as I can in IE when I debug the same code. Does anyone know whether XCelcius is simply no longer supporting this interface in a Mozilla/Firefox browser environment  any longer?
    Any help would be greatly appreciated.
    Thanks
    Jim

    Hi Suman,
    Thanks for the link to the Xcelcius SP3 Pam.
    I tried to also download the PAM for XCelscius 2008 SP5 but couldn't as it required a password for some reason. Any chance you could get it for me?
    To answer your questions, the version of my Firefox is 29.0.1 and  user Agent is Mozilla/5.0
    The PAM you provided for SP3 stated support for Mozilla Firefox 3.0  (maybe this could be a problem?)
    Having said that, my XCelcius flash object is displayed properly in Firefox and it runs properly in terms of functionality (e.g. updating charts, slider controls all work etc) . Where it fails is when my javascript attempts to call any of the External Interface data Connection methods. Example: getDataSource(rangename)
    This same thing works great in IE.
    Here is an interesting link to an example of someone who did use a Firefox browser and apparently successfully ran EIC methods to get data in and out of their two XCelcius flash modules. (This is pretty much  the same thing that I am doing too.)
    http://commxcelsiusdash.blogspot.com.au/2011/09/xcelsius-dashboard-communication.html
    Also, I have tried referencing the swf module in different ways depending upon your browser ( using this really helpful article)   http://www.permadi.com/tutorial/flashjscommand/

  • ITunes won't play songs w/Audio Interface connected

    I am using iTunes with a Tascam US-122L audio interface. It worked perfectly fine until yesterday evening, and now iTunes absolutely refuses to play any music when the Tascam is connected. I click a song title and the diamond slider does not move, the song stays at 0:00, and the "play" button doesn't change to the "pause" button. It seemed to have started doing this after I exported a song into iTunes from an app called Audio Hijack, which I downloaded to capture some audio from Logic Pro.
    iTunes works perfectly fine when the audio interface isn't connected.
    I've tried everything, from restarting my computer, to reinstalling the Tascam drivers to reinstalling iTunes, but to no avail. Anyone got any ideas?

    Does anyone have a possible solution to this? I'm getting the exact same issue with the US-122L after upgrading its firmware (believe it or not... it worked with the previous firmware.. silly me, if it ain't broke, don't fix it).
    Really considering returning the thing now, even though I really like it. I'd appreciate any leads, even a way to get debugging info out of it - I'm a programmer and I can tinker if needed. Thanks in advance.

Maybe you are looking for

  • Building+Deploying EAR, EJB and WS Proxy DCs

    Hi, I have three types of DCs in my track:- 1. Deployable Web Service ProxyDC 2. EJB Module DC (which uses classes from Deployable WS Proxy DC) 3. EAR Application DC (for above EJB DC) I am able to build and deploy EAR of WS Proxy DC successfully. Bu

  • Installation WRT54G2

    i purchased this router yesterday and now im trying to install it but the installation cd is giving me problems , i put the cd into the drive open and get to the main menu  but after clicking start setup  the window closes, is there a way to fix this

  • Firefox will not open give error can Windows can not find file firefox.exe

    when I try to open the install program for firefox I get error Windows can not file Programs\MozillaFirefox\firefox.exe tried to installing update to correct this no luck

  • Does NiVisa fix the Ethernet read buffer allocation bug?

    NiVisa 3.01 does not properly allocate memory for the read buffer and gives resource allocation error messages.

  • Exporting Surround AC-3 from FCP with Compressor

    I have a sequence in Final Cut with Video and the 6 audio tracks of a 5.1 surround configuration from the audio editor. I would like to be able to export the video as MPEG-2 and Audio as AC3 in one step using compressor. I understand how to assign th