Interface errors

Is there an script that can monitor interface errors (input and output errors) and send an email out when it reaches threshold?
Thanks
Sent from Cisco Technical Support iPhone App

Sure.  Here's an example:
event manager applet error_monitor_GigabitEthernet0/1
event interface name GigabitEthernet0/1 parameter input_errors entry-op ge entry-val 5 entry-type increment poll-interval 10
action 2.0 cli command "enable"
action 3.0 cli command "show int GigabitEthernet0/1 | inc error"
action 4.0 mail server 10.1.1.1 from [email protected] to [email protected] subject "Errors on interface GigabitEthernet0/1" body "
Interface GigabitEthernet0/1 has seen $_interface_delta_value input errors in the past 10 seconds: $_cli_result"

Similar Messages

  • Interface errors (crc, in/output, collisions etc.) via snmp

    Hi,
    I'm trying to understand how to get interface errors via SNMP.  I do get stats via SNMP for ifInErrors / ifOutErrors etc, but I'm trying to get output via SNMP for the errors visible via the 'sh int x' command - CRC errors, input / output errors, collisions, runts. giants etc.).
    1) The SNMP ifInError / ifOutError seems to give an overall counter of all errors from the time the device has started - Am I correct about this?
    2) Is there any way I can get the interface-specific errors noted above via SNMP?
    Thanks,
    Mario

    Depends on the device and version of code, but most likely you will get what you want from the CISCO-IF-EXTENSION-MIB.  Look at objects like cieIfInRuntsErrs, cieIfInGiantsErrs, and cieIfInFramingErrs.  You will also get some ethernet-specific errors from the ETHERLIKE-MIB.

  • Open DeviceNet interface error when TestStand call VIs of NI PCI-8532

    Hello,
    We use NI PCI-8532 was used as DeviceNet master to do functionality test with a slave (AC Drive).
    But when open DeviceNet interface, it happen the error.
    We can't find the solution and hope to find help from you.
    The basic sequence in TestStand is:
    1). Call "Open DeviceNet Interface.vi" to open interface and creat interface object.
         Interface(master) setting: interface name=dnet0, MAC ID=0, baudrate=125000bps
    2). Call "Open DeviceNet IO.vi" to creat DeviceNet IO object.
         Device(slave) setting: MAC ID=63
    3). Call "Operate DeviceNet Interface.vi" and operation code=start
    4). Call "Wait For State.vi"
    5). Call "Read DeviceNet IO.vi" to read data from IO object
    6). Call "Close Object.vi" to close IO object handle
    7). Call "Close Object.vi" to close interface object handle
    Remark, these DeviceNet VIs locates at "C:\Program Files\National Instruments\LabVIEW 2012\vi.lib\DeviceNet\VIAPI".
    First time to run sequece in TestStand, it can pass to run step 1) to open DeviceNet interface.
    But once there is some error with these steps, and it will happen "Open DeviceNet Interface" error (error code=0xBFF62006) when run these steps again.
    Then even use LabVIEW DeviceNet example to test, and it happen the same error except restart computer.
    The DeviceNet example locates at "C:\Program Files\National Instruments\LabVIEW 2012\examples\NI-Industrial Communications for DeviceNet\Basic Examples\PXI & PCI\MixedCommunication.vi".
    Some information more:
    PC operate system: Windows XP SP3
    LabVIEW version: 2012 SP1
    TestStand version: 2012 SP1
    PCI 8532 driver version: 2.3.0
    Other installed PCI board: PCI 8531 CANOpen

    The following errors may be resolved by resetting the CAN, DeviceNET or LIN device:
    Error -1074388986 occurred at ...
    NI-CAN:  (Hex 0xBFF62006) The object is already open in another application.  Solutions: Ensure that only one application at a time uses an object , and that you close all objects prior to exiting your application (don't use LabVIEW toolbar's Abort button).
    Error -1074388969 occurred at ...
    NI-CAN: (Hex 0xBFF62017) This attribute's value must be provided prior to the Open. Solutions: Set the attribute using the Config function before the Open, and do not set the attribute at any later time; Do not configure multiple CAN Objects for the same ID.
    SO,you should reset the DeviceNet.
    And another similar issue can explain some points of your problem  http://digital.ni.com/public.nsf/allkb/7D9383E9BEAD0B21862571640002F687?OpenDocument

  • Can't burn CD's - "Interface error 5"

    Hello, I haven't used my old firewire LaCie CD burner (LaCie 1394, blue front with the slide out tray) in a while but recently I needed to put some graphics files on a CD. The sw I'm using is Toast 6. No matter what I tyry to do I get the following message: "Interface Error: 5 The connection is not stable"
    I tried different CD brands, no effect.
    This is the setup.
    Machine Name: Power Mac G4 Cube
    Machine Model: PowerMac5,1
    CPU Type: PowerPC 60? (1.1)
    CPU Speed: 1.3 GHz
    L2 Cache (per CPU): 512 KB
    L3 Cache (per CPU): 2 MB
    Memory: 1.25 GB
    Bus Speed: 100 MHz
    Boot ROM Version: 4.1.9f1
    System Version: Mac OS X 10.4.2 (8C46)
    Kernel Version: Darwin 8.2.0
    Looking for answers I found an (unanswered) message on a macosx.com forum. I'm reposting it because it provides more info about the same problem:
    [quote]
    "Burning the disc failed because communication to the disc drive failed. (Error code 0x80020022)" -- Is the error code when I attempt to burn any disc using the Finder or Disk Utility.
    "Interface Error: 5 The connection is not stable.
    The drive reported an error:
    Sense Key = Illegal Request
    Sense Code = 0x210x02
    BUFFER UNDERRUN" --
    Are the errors when I attempt to use Toast Titanium v6.x and v7.x.
    I'm using an iMac G5 running 10.4.2. I have two burners, both of which give me the errors and will no longer burn to CD's or DVD's (cheap or expensive media, I've tried many different types). The burners i have are an internal superdrive that came with the mac (MATSHITA DVD-R UJ-825) and an external LaCie Firewire DL drive (_NEC DVD_RW ND-3500AG). Both drives started giving this error at the same time and I can't think of anything that I installed that could effect these. I don't have any speed tools installed.
    I have tried all that Apple suggests in the articles http://docs.info.apple.com/article.html?artnum=25750.
    I've experienced the same errors twice before, though not both drives at the same time. What fixed it the first time was simply upgrading the firmware on the burner. Second time, there were problems on the hard drive that I was burning from (directory issues if i remember) and running a combination of Tech Tool and Disk Utilitity fixed that.
    But this time, I'm at my wits end and can't find anything helpful online. I'm hoping to find an answer before I end up trying a complete system reinstall.
    Any info would be greatly appreciated.
    [/quote]
    Yes, any info ...
    TIA
    Cube, 2 ibooks   Mac OS X (10.4.2)  

    I'm having the same problem using Toast 7 to burn a Video TS movie I made. I'm using an external Lacie 16X DVD-R DL drive and an iMac G5 2.0, and Mac OS 10.4.3
    After several failures with Interface Error 5, I tried copying a DVD movie I made from another DVD. This was created with the same Lacie drive using Mac OS 10.3 and my old iMac FP 15 inch. I got the same failure message.
    I then switched my Lacie Drive to the USB port and everything is working fine. I switched it back to FireWire and I get the same error message again.
    I can play DVD's on the Lacie with either the USB or FireWire port without any problem, I just can't record using the FireWire port. The FireWire ports on the computer work fine with all my other FireWire devices.
    It must be a combination of 10.4.3, Toast 7 and Lacie FireWire. I'm going to recheck Lacie's site to make sure I have all of the updates.
    iMac G5   Mac OS X (10.4.2)   Mac OS 10.4.3

  • EEM interface errors not matching

    I have the event applet configured below.  I test by changing the controller time-slots to 1-15 instead of 1-24 in order to generate errors on my Serial0/1/0:0 interface.  Errors are generated, but the eem applet does not match even though the errors are incrementing.  I've turned on all suggested eem debugging and it shows 0 matches while I can see that the interface is incrementing the errors that should be triggering the actions from the eem.  
    configuration:
    event manager applet multiple_if
    event tag if_1 interface name Serial0/1/0:0 parameter input_errors_crc entry-op ge entry-val 2 entry-type increment poll-interval 60
    event tag if_2 interface name Serial0/1/0:0 parameter input_errors entry-op ge entry-val 2 entry-type increment poll-interval 60
    event tag if_3 interface name Serial0/1/0:0 parameter input_errors_frame entry-op ge entry-val 2 entry-type increment poll-interval 60
    event tag if_4 interface name Serial0/1/0:0 parameter input_errors_overrun entry-op ge entry-val 2 entry-type increment poll-interval 60
    event tag if_5 interface name Serial0/1/0:0 parameter output_errors entry-op ge entry-val 2 entry-type increment poll-interval 60
    event tag if_6 interface name Serial0/1/0:0 parameter output_errors_underrun entry-op ge entry-val 2 entry-type increment poll-interval 60
    trigger
    action 100 cli command "enable"
    action 200 cli command "config t"
    action 300 cli command "int Serial0/1/0:0"
    action 400 cli command "description script worked!"
    action 500 syslog msg "CRC failure leased line $_interface_name"
    action 600 mail server "$_mail_smtp" to "$_mail_rcpt" from "$_info_routername@$_mail_domain" subject "ALERT: Serial Interface $id shutdown due to excessive interface error rate" body "\n$_syslog_msg"
    action 999 end
    debug ouput:
    Jun 20 14:20:48 EDT: fh_fd_syslog_event_match: num_matches = 0
    Jun 20 14:20:48 EDT: fh_fd_data_syslog: num_matches = 0
    Jun 20 14:20:48 EDT: fh_fd_syslog_event_match: num_matches = 0
    Jun 20 14:20:48 EDT: fh_fd_data_syslog: num_matches = 0
    Jun 20 14:21:00 EDT: fh_fd_timer_process_async
    Jun 20 14:21:00 EDT: cron_tick: num_matches 0
    Jun 20 14:21:22 EDT: %HSRP-5-STATECHANGE: FastEthernet0/0.4 Grp 4 state Standby -> Active
    Jun 20 14:21:22 EDT: fh_fd_syslog_event_match: num_matches = 0
    Jun 20 14:21:22 EDT: fh_fd_data_syslog: num_matches = 0
    Jun 20 14:22:00 EDT: fh_fd_timer_process_async
    Jun 20 14:22:00 EDT: cron_tick: num_matches 0
    Jun 20 14:23:00 EDT: fh_fd_timer_process_async
    Jun 20 14:23:00 EDT: cron_tick: num_matches 0
    Jun 20 14:24:00 EDT: fh_fd_timer_process_async
    Jun 20 14:24:00 EDT: cron_tick: num_matches 0
    output showing interface errors:
    csc-lab01#sh int s0/1/0:0
    Serial0/1/0:0 is up, line protocol is up
      Hardware is GT96K Serial
      Internet address is x.x.x.x/30
      MTU 1500 bytes, BW 1536 Kbit/sec, DLY 20000 usec,
         reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation PPP, LCP Open
      Listen: CDPCP
      Open: IPCP, loopback not set
      Keepalive set (10 sec)
      CRC checking enabled
      Last input 00:00:00, output 00:00:00, output hang never
      Last clearing of "show interface" counters 02:44:23
      Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: Class-based queueing
      Output queue: 0/1000/0 (size/max total/drops)
      30 second input rate 2000 bits/sec, 3 packets/sec
      30 second output rate 2000 bits/sec, 2 packets/sec
         9139 packets input, 1049231 bytes, 0 no buffer
         Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
         224 input errors, 224 CRC, 117 frame, 95 overrun, 0 ignored, 81 abort
         10737 packets output, 1511507 bytes, 0 underruns
         0 output errors, 0 collisions, 15 interface resets
         0 unknown protocol drops
         0 output buffer failures, 0 output buffers swapped out
         0 carrier transitions
      Timeslot(s) Used:1-24, SCC: 0, Transmitter delay is 0 flags

    A few other things I noticed.  Try this:
    event manager applet multiple_if
    event tag if_1 interface name  Serial0/1/0:0 parameter input_errors_crc entry-op ge entry-val 2  entry-type increment poll-interval 60
    event tag if_2 interface  name Serial0/1/0:0 parameter input_errors entry-op ge entry-val 2  entry-type increment poll-interval 60
    event tag if_3 interface  name Serial0/1/0:0 parameter input_errors_frame entry-op ge entry-val 2  entry-type increment poll-interval 60
    event tag if_4 interface  name Serial0/1/0:0 parameter input_errors_overrun entry-op ge entry-val 2  entry-type increment poll-interval 60
    event tag if_5 interface  name Serial0/1/0:0 parameter output_errors entry-op ge entry-val 2  entry-type increment poll-interval 60
    event tag if_6 interface  name Serial0/1/0:0 parameter output_errors_underrun entry-op ge  entry-val 2 entry-type increment poll-interval 60
    trigger occurs 1
    correlate event if_1 or event if_2 or event if_3 or event if_4 or event if_4 or event if_5 or event if_6
    action 100 cli command "enable"
    action 200 cli command "config t"
    action 300 cli command "int Serial0/1/0:0"
    action 400 cli command "description script worked!"
    action 401 set syslog_msg "CRC failure leased line $_interface_name"
    action 500 syslog msg "$syslog_msg"
    action 501 info type routername
    action 600 mail server "$_mail_smtp" to "$_mail_rcpt" from  "$_info_routername@$_mail_domain" subject "ALERT: Serial Interface $_interface_name  shutdown due to excessive interface error rate" body "\n$syslog_msg"

  • Can we set the Option "Show add-in user interface errors" with VBA?

    Does anyone know if the advanced Option "Show add-in user interface errors" can be set with VBA in Project Pro 2013?
    \Spiro Theopoulos, Montreal, QC (Canada)

    Spiro,
    Sorry but as far as I know that option is not available through VBA.
    John

  • Help: Net.lib interface error

    Hi!
    I'm using the Palm Emulator to make a HTTP connection to my servlet. The same MIDlet works on my Palm, but when I run it on the emulator (in order to some screen captures), I get error mesg that says "Net.lib interface error: 0x0000120C", followed by java.io.IOException.
    I've already set my proxy IP ...
    Can someone pls help? TIA!
    Rgds

    Hi ....
    Is anyone have any ideas to solved if this problem occur on the real palm m505 machine ??
    Please advice and kindly reply
    Thank
    SL

  • What types of Interface Errors lead to Input/Output Drops/Discards?

    Hi All,
    I was wondering if anyone knows if all of the following errors would lead to packet drops/discards.
    Runts
    Giants
    Framing Errors
    Overrun Errors
    Abort Errors
    Also, are there any types of interface errors that don't lead to packet drops/discards?
    So if all interface errors lead to packet drops/discards, I may not have to poll for multiple OIDs for these errors, but instead just poll for packet drops/discards.
    Any insight would be appreciated.
    Thanks,
    David

    ifInDrops do not related to errors.  In fact, ifInDiscards specifically count packets that were discarded without an associated error.  This could be due to a lack of buffer space (e.g. no queue slot), or there was no listener for a TCP connection.  The same is true for ifOutDiscards.
    For a consolidated error count, look at ifInErrors and ifOutErrors.  It will depend on the interface/encapsulation type as to what exactly will be counted as an error, but anything that would be an encap-specific error should appear in one of the interface error counters.

  • ACE FT interface errors

    I have 2 ACE appliances running in active/standby.  On each appliance I have port 3 used for FT and port 4 used for server traffic.  Every one of the connections terminates on a 3750 10/100 switch.  The switch ports (all configured as access ports) are configured the same way and each of the connections from port 4 (the server port) works great with no interface errors.  However, on BOTH ACE appliances, port 3, (the FT port) causes non-stop input errors and runts on the switch interface and failover will not work.  I have tried to hardset the speed/duplex on both devices and every other possible combination with no success.  AS A TEST ONLY --> When I plugged each of the FT interfaces into a $10 linksys hub, failover worked perfectly.
    Since using the $10 hub is not an option, any ideas on what I can try to fix the issue?

    The FT interface is  a trunk interface.
    You have to set your switch to trunking mode not access mode.
    This is explained somewhere in the documentation.
    Gilles.

  • SQL 2008 R2 error: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified

    after some year work with SQL server 2005,i decide change to  SQL server 2008 R2.
    When i completed install SQL 2008 R2,i can't connected to SQL server due to this following error
    A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider:
    SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified) (.Net SqlClient Data Provider)
    And when i click to technical details,i take some thing like this
    ===================================
    Cannot connect to HUY-PC\SQLEXPRESS.
    ===================================
    A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider:
    SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified) (.Net SqlClient Data Provider)
    For help, click: http://go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&EvtSrc=MSSQLServer&EvtID=-1&LinkId=20476
    Error Number: -1
    Severity: 20
    State: 0
    Program Location:
       at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
       at System.Data.SqlClient.TdsParser.Connect(ServerInfo serverInfo, SqlInternalConnectionTds connHandler, Boolean ignoreSniOpenTimeout, Int64 timerExpire, Boolean encrypt, Boolean trustServerCert, Boolean integratedSecurity, SqlConnection owningObject)
       at System.Data.SqlClient.SqlInternalConnectionTds.AttemptOneLogin(ServerInfo serverInfo, String newPassword, Boolean ignoreSniOpenTimeout, Int64 timerExpire, SqlConnection owningObject)
       at System.Data.SqlClient.SqlInternalConnectionTds.LoginNoFailover(String host, String newPassword, Boolean redirectedUserInstance, SqlConnection owningObject, SqlConnectionString connectionOptions, Int64 timerStart)
       at System.Data.SqlClient.SqlInternalConnectionTds.OpenLoginEnlist(SqlConnection owningObject, SqlConnectionString connectionOptions, String newPassword, Boolean redirectedUserInstance)
       at System.Data.SqlClient.SqlInternalConnectionTds..ctor(DbConnectionPoolIdentity identity, SqlConnectionString connectionOptions, Object providerInfo, String newPassword, SqlConnection owningObject, Boolean redirectedUserInstance)
       at System.Data.SqlClient.SqlConnectionFactory.CreateConnection(DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningConnection)
       at System.Data.ProviderBase.DbConnectionFactory.CreateNonPooledConnection(DbConnection owningConnection, DbConnectionPoolGroup poolGroup)
       at System.Data.ProviderBase.DbConnectionFactory.GetConnection(DbConnection owningConnection)
       at System.Data.ProviderBase.DbConnectionClosed.OpenConnection(DbConnection outerConnection, DbConnectionFactory connectionFactory)
       at System.Data.SqlClient.SqlConnection.Open()
       at Microsoft.SqlServer.Management.SqlStudio.Explorer.ObjectExplorerService.ValidateConnection(UIConnectionInfo ci, IServerType server)
       at Microsoft.SqlServer.Management.UI.ConnectionDlg.Connector.ConnectionThreadUser()
    Please!!!Some body help me solve this problem(except format my computer),i really really need your advice.

    Hi huydaibang,
    The older version SQL Server 2005 could be installed with SQL Server 2008 R2 side-by-side.  It could not be the problem.
    The reason that we get this error message is the client stack could not receive SSRP response UDP packet from SQL Browser.
    Here are the steps:
    1) Make sure your server name is correct, e.g., no typo on the name.
    2) Make sure your instance name is correct and there is actually such an instance on your target machine.
    3) Make sure the server machine is reachable, e.g, DNS can be resolve correctly, you are able to ping the server (not always true).
    4) Make sure SQL Browser service is running on the server.
    5) If firewall is enabled on the server, you need to put sqlbrowser.exe and/or UDP port 1434 into exception.
    For more information, please refer to
    http://blogs.msdn.com/b/sql_protocols/archive/2007/05/13/sql-network-interfaces-error-26-error-locating-server-instance-specified.aspx.
    Thanks,
    Maggie
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. This can be beneficial to other community members reading the thread.

  • Bad interface error message

    I've written a vi (& built an executable) to run either continuously grab or snap images from a PCI 1424. The machine with the card in isn't the development machine an dis running imaq 2.1 with a very simple imaq configuration utility. This can be used to grab images.
    The application was built on labview 6.1 with MAX tells me imaq 2.5.2. If I try and run the application and grab images I get a bad interface error message, could this be caused by the vastly different versions of imaq and if so is installing 2.5.1 and upgrading both the development machine and deployment machine to 2.5.5 likely to solve the problem. Is this also an irreversible step incase it doesn't work.

    Having matching versions of IMAQ on both computers can be very helpful. I think it will solve your problem. You should be able to uninstall IMAQ and reinstall the old version if there are more problems.
    I would also advise uninstalling the old IMAQ before installing the new version.
    Bruce
    Bruce Ammons
    Ammons Engineering

  • Intermitten error - SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified

    Problem: I have a 2 WFE & 1 App server in my SharePoint 2013 Enterprise Edition SharePoint farm.  My WFE 2 and App servers connect all the time to the SQL Server using a SQL alias.  My WFE1 server work 80% of the
    time.  It is setup exactly like WFE2 except periodically 1 web app/site collection will stop working and throw the following error:
    "A network-related or instance-specific error occurred while establishing a
    connection to SQL Server. The server was not found or was not accessible. Verify
    that the instance name is correct and that SQL Server is configured to allow
    remote connections. (provider: SQL Network Interfaces, error: 26 - Error
    Locating Server/Instance Specified)"
    When I log into WFE1 I can connect to SQL using the alias using a udl file and telnet to verify the SQL alias is connected.
    Hypothesis/guess:  It appears like WFE1 periodically looses networking but only for 1 specific site collection. 
    Any ideas are most welcome?

    Hi Aries,
    I can rule out SQL Server (AOAG) Always-on as the farm doesn't use it. 
    "max worker threads" is set to 512 with 4CPU's.  Rule out.
    From the log and looking at the breakdown of the SharePoint request, the request is hitting the WFE2 server which in turn is trying to connect to the content database.  The connection string/instance is not available.  In summary, I believe the
    issue is WFE2 periodically cannot connect to the SQL instance.  At the same time WFE1 is working so we know it isn't the SQL server.  WFE1 & WFE 2 are on the same VLAN and both appear connected and can see the SQL database using a udl file. 
    WFE2 has other web applications that are working while the erring web site fails.  An IIS reset fixes the issue and restarting the "App pool" for the offending IIS website also fixes the problem.  This tells me the issue
    is the IIS process.  When it tries to connect to SQL /the content database it fails.
    I already raised the ticket with MS , the engineer has been looking at it with me, we have tried to identify the issue and also looked at TCP Chimney offload being a possible issue.  As my servers is Windows Server 2012, all the servers have the default
    "TCP Chimney Offload" setting set to "disabled".  WFE1, WFE2, APP1 and SQL have the same setting so this is not the issue.  At least this has been ruled out.
    http://support.microsoft.com/kb/951037
    http://blogs.msdn.com/b/psssql/archive/2008/10/01/windows-scalable-networking-pack-possible-performance-and-concurrency-impacts-to-sql-server-workloads.aspx
    I will keep posting about the problem, hopefully MS support can escalate and the root cause can be determined.
    "The bottleneck is on the WFE2 server process trying to communicate with SQL.  SQL is up and listening.  Only 1 of the website/WebApplication on WFE fail for 15-20 minutes while the other websites are fine."

  • Lync SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified

    Dear all,
    I'm getting an error when I want to publish my Lync Topology. Thanks in advance.
    error:
    Error: A network-related or instance-specific error occurred while
    establishing a connection to SQL Server. The server was not found or was not
    accessible. Verify that the instance name is correct and that SQL Server is
    configured to allow remote connections. (provider: SQL Network Interfaces,
    error: 26 - Error Locating Server/Instance Specified)

    Hi,
    Would you please elaborate your Lync server environment?
    Did the FE server and BE server on different subnets? If so, please try to relocate the SQL server in the same subnet as FE server and then check again.
    Please also double check if the step of “Prepare first Standard Edition Server” ran succeed, if not please run again.
    Here is a blog may help you:
    http://terenceluk.blogspot.com/2011/05/publishing-lync-server-2010-standard.html
    Note: Microsoft is providing this information as a convenience to you. The sites are not controlled by Microsoft. Microsoft cannot make any representations regarding the quality, safety, or suitability of any software
    or information found there. Please make sure that you completely understand the risk before retrieving any suggestions from the above link.
    Best Regards,
    Eason Huang
    Eason Huang
    TechNet Community Support

  • Why do I keep getting Error 519: Server interface error" - Server interface error "no component returned from creativewidget' Line: 479 - var test = parent.add('statictext', undefined, text)  when I try to use pattern fill/scripted patterns.  I have unin

    Why do I keep getting Error 519: Server interface error" - Server interface error "no component returned from creativewidget' Line: 479 -> var test = parent.add('statictext', undefined, text)  when I try to use pattern fill/scripted patterns.  I have uninstalled and re-installed PS CC.  I have opened holding down shift to disable third party plug-ins.  I have moved 3rd party plugins to a temp location outside of ps and it still doesn't help.  It worked once, and only once and now won't work at all.

    Unless your Photoshop question has to do with a download/install error, you should ask in Photoshop General Discussion
    The Cloud forum is not about using individual programs
    The Cloud forum is about the Cloud as a delivery & install process
    If you will start at the Forums Index https://forums.adobe.com/welcome
    You will be able to select a forum for the specific Adobe product(s) you use
    Click the "down arrow" symbol on the right (where it says All communities) to open the drop down list and scroll

  • Requisition Import Interface error

    Hi All,
    I have an Out side processing Item in a BOM and when I perform move transactions, as soon as the comes to Queue stage of Out side Processing Operation, system firing requisition import program. every thing is fine till here.
    After running requisition import program , requisition is going into interface errors saying that,"Accrual account is invalid and variance account is invalid". please assign a valid accrual account and valid variance account. Please suggest me.
    Regards
    Balaji Pallela

    Verify that the following accounts are valid.
    Inventory > Setup > Organizations > Parameters > Other Accounts > Cost Variance Account
    Purchasing > setup > Organizations > Purchasing Options > Receipt Accounting > Expense AP Accrual Account
    Make sure the accounts are not restricted by security rules.
    GL > Setup > Financials > Flexfields > Validations > Security

Maybe you are looking for

  • Error in Call Adapter step

    Hello, We have RFC --> HTTPS scenario. The RFC Destination of type G is created in XI and the connection test is working fine. When I run this scenario, sometimes I get following error: com.sap.aii.af.ra.ms.api.DeliveryException: XIAdapter:ATTRIBUTE_

  • Why there is no quick selection function in adobe photoshop 6.0.1 [was: cs6.01]?

    Some one my help? why there is no quick selection function in my adobe photoshop 6.0.1 [was: cs 6.01]?

  • Where clause sequence

    Hi select /some fields/ where clause field1=:b1 and field2=:b2 etc; Does sequence of field1 field2 in where cluase matters in reducing fetch time i.e select /some fields/ where field2=:b2 etc and field1=:b1 will be faster Prashant

  • Can i run 9ias versions 1 and 2 on the same machine

    i need to install 9ias versions 1 and 2 on the same machine but in separate databases, is this possible? if it is possible are there any issues that i need to be aware of?

  • Help! Can'i install Solaris 9 on Dell Laptitude LS

    Can'i install Solaris 9 on Dell Laptitude LS. Setting of video card and monitor fail. My configuration is: P3 450 128MB MagicMedia 256 AV video and sound card. Monitor unknown with 800*600 resolution. Anyone has idea about that. Thanks!