Invisible Selection Screen(Low and High) accordingly through radio-button
Dear Experts,
Currently I've faced some problem regarding selection-screen.Our user want that when he click P1(say) radio-button, then selection-screen "s1-high " is invisible and when he click P2(say) radio-button that time "s1-low" is invisible.
So can anybody tell me the how can i do it?
warm regards,
sameek mazumder.
Hi Sameek,
If user clicks radio button P2 then how can s1-low become invisible? Do you mean when radio button P2 is clicked program will not display the select option at all?Since If s1-low becomes invisible there is no point of s1-high in the display. Please clarify your requirement.
However, I think that if it can be something like if radio button 1 is pressed s1-low is visible. If radio button 2 is pressed normal select option is displayed. Please check the following code to achieve this:
DATA: gv_matnr TYPE matnr.
PARAMETERS : p_rb1 RADIOBUTTON GROUP g1 USER-COMMAND radio,
p_rb2 RADIOBUTTON GROUP g1.
SELECT-OPTIONS s_matnr FOR gv_matnr.
AT SELECTION-SCREEN OUTPUT.
LOOP AT SCREEN.
IF screen-name CS 'S_MATNR-HIGH'.
CASE 'X'.
WHEN p_rb1.
screen-active = 0.
WHEN p_rb2.
*Do nothing
ENDCASE.
ENDIF.
MODIFY SCREEN.
ENDLOOP.
INITIALIZATION.
LOOP AT SCREEN.
IF screen-name CS 'S_MATNR-HIGH'.
screen-active = 0.
MODIFY SCREEN.
ENDIF.
ENDLOOP.
Hope this would help.
BR,
Atanu
Similar Messages
-
Select-options split date into month and assign to low and high
Hi,
In my select-options i am giving BEDAT (01.04.2004 TO 30.10.2005).I need to split month and
year in separate fields.that is
select-option_low-month in one field
select-option_high-month in second field
select-option_low-year in third field
select-option_high-year in fourth field.
Finally i need to move these four fields to it_final.
select * from mbewh into corresponding fields of table it_mbewh
for all entries in it_final where matnr = it_final-matnr and
bwkey = it_final-werks and lpmon = ? and lfgja = ?
and bklas <> ' '.
what input i have to give in lpmon and lfgja in select query to get for lfmon (04 to 10)
and lfgja (2004 to 2005).
suggest some ideas.Hi ,
Can you please check the following code.
Hi ,
data : l_low_yr(4),
l_high_yr(4),
l_low_mon(2),
l_high_mon(2).
Splitting the select option date to month and year into low and higher values
l_low_yr = s_date-low+00(04). " Year low value from the date range
l_low_mon = s_date-low+04(02). " Month low value from the date range
l_high_yr = s_date-high+00(04)." Year high value from the date range
l_high_mon = s_date-high+04(02)." Month high value from the date range
selecting the data from the table mbewh based on some conditions.
select * from mbewh into corresponding fields of table it_mbewh
for all entries in it_final where matnr = it_final-matnr and
bwkey = it_final-werks and lfmon BETWEEN l_low_mon and l_high_mon
and lfgja BETWEEN l_low_yr and l_high_yr and bklas EQ ' '.
This select will retrive the desired data records from the table MBEWH.
Please let me know if this works according to your requirement.
Thanks and Regards
Saritha -
At selection-screen output and at selection-screen on
Hi Experts,
I had coded in both at selection-screen output for disabling input of certain fields and at selection-screen for validation like this:
AT SELECTION-SCREEN output.
IF p_amt = 'X'.
LOOP AT SCREEN.
CASE screen-name.
WHEN 'P_AMT'.
screen-input = '1'.
WHEN 'P_TST'.
screen-input = '1'.
WHEN 'P_B4C'.
screen-input = '1'.
WHEN 'P_AFC'.
screen-input = '1'.
WHEN 'P_COM'.
screen-input = '1'.
WHEN 'P_COM1'.
screen-input = '1'.
WHEN 'P_COM2'.
screen-input = '1'.
WHEN OTHERS.
screen-input = '0'.
ENDCASE.
MODIFY SCREEN.
ENDLOOP.
ENDIF.
IF p_amt = 'X'.
LOOP AT SCREEN.
CASE screen-name.
WHEN 'P_AMT'.
screen-input = '1'.
WHEN 'P_TST'.
screen-input = '1'.
WHEN 'P_B4C'.
screen-input = '1'.
WHEN 'P_AFC'.
screen-input = '1'.
WHEN 'P_COM'.
screen-input = '1'.
WHEN 'P_COM1'.
screen-input = '1'.
WHEN 'P_COM2'.
screen-input = '1'.
WHEN OTHERS.
screen-input = '0'.
ENDCASE.
MODIFY SCREEN.
ENDLOOP.
ENDIF.
IF p_pdf = 'X'.
LOOP AT SCREEN.
CASE screen-name.
WHEN 'P_PDF'.
screen-input = '1'.
WHEN 'P_TST'.
screen-input = '1'.
WHEN 'P_PATH'.
screen-input = '1'.
WHEN OTHERS.
screen-input = '0'.
ENDCASE.
MODIFY SCREEN.
ENDLOOP.
ENDIF.
IF p_afc = 'X'.
LOOP AT SCREEN.
CASE screen-name.
WHEN 'P_TST'.
screen-input = '1'.
WHEN 'S_FID-LOW' OR 'S_FID-HIGH'.
screen-input = '0'.
WHEN 'S_ORG-LOW' OR 'S_ORG-HIGH'.
screen-input = '0'.
WHEN 'S_OFF-LOW' OR 'S_OFF-HIGH'.
screen-input = '0'.
WHEN 'S_DAT-LOW' OR 'S_DAT-HIGH'.
screen-input = '0'.
ENDCASE.
MODIFY SCREEN.
ENDLOOP.
ENDIF.
AT selection-screen on block b5.
if p_tst is initial.
message text-016 type 'E'.
endif.
AT selection-screen on block b2.
if p_amt ne 'X' and p_pdf ne 'X'.
if s_fid is initial and s_org is initial.
message text-000 type 'E'.
endif.
if s_dat is initial.
message text-000 type 'E'.
endif.
endif.
when i comment out at selection-screen validations the input is disabled for the screen fields as set, else the validations are executed first.
Any solution for this???
Thanks in advance.AT SELECTION-SCREEN
Syntax
AT SELECTION-SCREEN selscreen_event.
Effect
This statement defines event blocks for different events selscreen_event that are triggered by the ABAP runtime environment during selection screen processing.
Selection screen events occur immediately before sending a selection screen and after certain user actions on a displayed selection screen. They assist in selection screen processing in the ABAP program.
AT SELECTION-SCREEN is triggered at least twice during actions on selection screens that are linked into another selection screen as a subscreen - first for the linked selection screen itself, and then for the linking selection screens.
Note
The event blocks after AT SELECTION-SCREEN are implemented internally as procedures. Declarative statments in these event blocks create local data. -
How to get selection screen elements and its table reference of a report ?
halo experts
How can I get selection screen elements and its table reference of a report ? . I tried rs_refresh_from_select_options. But I am unable to get the table and field it is referring to
For eg if my selection screen 1000 is
parameters: p_carrid type spfli-carrid,
select-options :s-_connid type sflight-connid.
is there any Fm or method which gives me what are the screen elements( p_carrid and s_connid ) and what table( splfi and sflight ) and field ( carrid and conid )it is referring to ?The following code is an example of how you might dynamically determine all your PARAMETERS and SELECT-OPTIONS variables at run time. The PARAMETERS and SELECT-OPTIONS only point to a dictionary element--not a specific table. Even though you may say "spfli-carrid" or "sflight-connid", the data type really references the dictionary type and not a specific table/structure.
REPORT ZTEST_PROG.
TABLES sflight.
DATA:
screen_tab TYPE STANDARD TABLE OF screen,
wa_screen TYPE screen,
scrn_nm TYPE string,
scrn_leftover TYPE string,
l_type TYPE REF TO cl_abap_typedescr,
typ_nm TYPE string,
typ_pre TYPE string.
FIELD-SYMBOLS <fs_data> TYPE ANY.
PARAMETERS p_carrid TYPE spfli-carrid.
SELECT-OPTIONS s_connid FOR sflight-connid.
INITIALIZATION.
LOOP AT SCREEN.
IF screen-group3 = 'PAR'
OR screen-group3 = 'LOW'.
APPEND screen TO screen_tab.
ENDIF.
ENDLOOP.
START-OF-SELECTION.
LOOP AT screen_tab INTO wa_screen.
ASSIGN (wa_screen-name) TO <fs_data>.
l_type = cl_abap_typedescr=>describe_by_data( <fs_data> ).
IF wa_screen-group3 = 'LOW'.
SPLIT wa_screen-name AT '-' INTO scrn_nm scrn_leftover.
TRANSLATE scrn_nm TO UPPER CASE.
ELSE.
scrn_nm = wa_screen-name.
ENDIF.
SPLIT l_type->absolute_name AT '=' INTO typ_pre typ_nm.
WRITE:
/ 'Screen Name: ', scrn_nm,
/ 'DDIC Type: ', typ_nm.
ENDLOOP.
When you get into defining internal tables you can determine those at run time with cl_abap_structdescr. The following is an example of how you might do that. You can loop through the "components_table" and evaluate each field of the structure in this way.
DATA: structure_reference TYPE REF TO cl_abap_structdescr,
components_table TYPE abap_compdescr_tab,
components_structure LIKE LINE OF components_table.
structure_reference ?= cl_abap_structdescr=>describe_by_data( any_structure ).
components_table = structure_reference->components.
I don't know if this answers any of your questions but I hope that some of it is useful. -
At-selection screen output and radio button together
Hi all,
I want to make a screen with radio buttons and a drop down menu on selection screen as soon as I check any button and click on Open from drop down menu the output should come according to the button cheked but the problem is that desired output is not coming.
Please see if something could be done.
Thanks,
ShwetaHi,
Here is the code see y it didnt responds,
I made ZMENU2 in SE41 with Menu bar as OPEN , also activated buttons BACK and EXIT.
tables : sscrfields.
CONSTANTS : buttonselected TYPE c LENGTH 1 VALUE 'X'.
DATA: ok_code LIKE sy-ucomm.
SELECTION-SCREEN BEGIN OF BLOCK frame1 WITH FRAME TITLE text-001.
SELECTION-SCREEN ULINE /1(60).
PARAMETERS: first RADIOBUTTON GROUP rad DEFAULT 'X',
second RADIOBUTTON GROUP rad,
third RADIOBUTTON GROUP rad,
fourth RADIOBUTTON GROUP rad,
fifth RADIOBUTTON GROUP rad.
SELECTION-SCREEN END OF BLOCK frame1.
AT SELECTION-SCREEN OUTPUT.
SET PF-STATUS 'ZMENU2'.
If first = buttonselected and ok_code = 'OPEN'..
WRITE 'You selected first button'.
ELSEIF second = buttonselected and ok_code = 'OPEN'..
WRITE 'You selected second button'.
ELSEIF third = buttonselected and ok_code = 'OPEN'.
WRITE 'You selected third button'.
ELSEIF fourth = buttonselected and ok_code = 'OPEN'.
WRITE 'You selected fourth button'.
ELSEIF fifth = buttonselected and ok_code = 'OPEN'.
WRITE 'You selected fifth button'.
ELSEIF ok_code ='BACK'.
LEAVE PROGRAM.
ELSEIF ok_code ='EXIT'.
LEAVE PROGRAM.
ENDIF. -
Table AGR_1251: Search between a range of the field "LOW" and "HIGH
Hello Experts,
i've got a problem by searching all users who have the authority for a transaction.
The transaction was written in a parameter, called p_trans.
I've the Tables AGR_1251, AGR_AGRS and AGR_USERS.
I know what I've to do.
Here is my Join.
SELECT agru~uname
INTO CORRESPONDING FIELDS OF TABLE gt_users
FROM agr_1251 as ag12
INNER JOIN agr_agrs as agrs
ON ag12~agr_name = agrs~child_agr
INNER JOIN agr_users as agru
ON agrs~agr_name = agru~agr_name
INNER JOIN usr01 as us
ON agru~uname = us~bname
WHERE ag12~object = 'S_TCODE' AND
ag12~field = 'TCD' AND
???? parameter p_trans between ag~low and ag~high????
SELECT agru~uname
APPENDING TABLE gt_users
FROM agr_1251 as ag12
INNER JOIN agr_agrs as agrs
ON ag12~agr_name = agrs~child_agr
INNER JOIN agr_users as agru
ON agrs~child_agr = agru~agr_name
INNER JOIN usr01 as us
ON agru~uname = us~bname
WHERE ag12~object = 'S_TCODE' AND
ag12~field = 'TCD' AND
???? parameter p_trans between ag~low and ag~high????
SORT gt_users BY uname ASCENDING.
DELETE ADJACENT DUPLICATES FROM gt_users COMPARING uname.
Here is my question:
In my code are question marks...here i want to say, that my transaction lays between the fields LOW and HIGH.
But how can i say, that in WHERE.
I have to say... Search that agr_name, where object = s_tcode, field=tcd and where my transaction lies between.
For example: low is T and high is X and i have the transaction va21.
So i must find out, in which range lays ma transaction.
I hope somebody understands me
Thanks!
Regards,
MarcelHi Marcel,
You are mentioning it as a parameter between having low & high values. Is it a parameter or select option.
If its a parameter, then anyway it will have only single value at any point of time.
If its a select option, then you need to use
select * from
and tcode in s_tcode.
Thanks,
Best regards,
Prashant -
I am retrieving high and low limits from step results in VB code that looks something like this:
' (This occurs while processing a UIMsg_Trace event)
Set step = context.Sequence.GetStep(previousStepIndex, context.StepGroup)
'(etc.)
' Get step limits for results
Set oStepProperty = step.AsPropertyObject
If oStepProperty.Exists("limits", 0&) Then
dblLimitHigh = step.limits.high
dblLimitLow = step.limits.low
'(etc.)
So far, so good. I can see these results in
VB debug mode.
Immediately after this is where I try to put the limits into the results list:
'Add Limits to results
call mCurrentExecution.AddExtraResult("Step.Limits.High", "UpperLimit")
call mCurrentExecution.AddExtraResult("Step.Limits.Low", "LowerLimit")
(No apparent errors here while executing)
But in another section of code when I try to extract the limits, I get some of the results, but I do not get any limits results.
That section of code occurs while processing a UIMsg_EndExecution event and looks something like this:
(misc declarations)
'Get the size of the ResultList array
Call oResultList.GetDimensions("", 0, sDummy, sDummy, iElements, eType)
'Step through the ResultList array
For iItem = 0 To iElements - 1
Dim oResult As PropertyObject
Set oResult = oResultList.GetPropertyObject("[" & CStr(iItem) & "]", 0)
sMsg = "StepName = " & oResult.GetValString("TS.StepName", 0) & _
", Status = " & oResult.GetValString("Status", 0)
If oResult.Exists("limits", 0&) Then
Debug.Print "HighLimit: " & CStr(oResult.GetValNumber("Step.Limits.High", 0))
Debug.Print "LowLimit: " & CStr(oResult.GetValNumber("Step.Limits.Low", 0))
End If
'(handle the results)
Next iItem
I can get the step name, I can get the status, but I can't get the limits. The "if" statement above which checks for "limits" never becomes true, because, apparently the limit results never made it to the results array.
So, my question again is how can I pass the low and high limit results to the results list, and how can I retrieve the same from the results list?
Thanks,
GriffGriff,
Hmmmm...
I use this feature all the time and it works for me. The only real
difference between the code you posted and what I do is that I don't
retrieve a property object for each TestStand object, instead I pass the
entire sequence context (of the process model) then retrieve a property
object for the entire sequence context and use the full TestStand object
path to reference sub-properties. For example, to access a step's
ResultList property called "foo" I would use the path:
"Locals.ResultList[0].TS.SequenceCall.ResultList[].Foo"
My guess is the problem has something to do with the object from which
you're retrieving the property object and/or the path used to obtain
sub-properties from the object. You should be able to break-point in the
TestStand sequence editor immediately after the test step in question
executes, then see the extra results in the step's ResultList using the
context viewer.
For example, see the attached sequence file. The first step adds the extra
result "Step.Limits" as "Limits", the second step is a Numeric Limit (which
will have the step property of "Limits") test and the third step pops up a
dialog if the Limits property is found in the Numeric Limit test's
ResultList. In the Sequence Editor, try executing with the first step
enalbled then again with the first step skipped and breakpoint on the third
step. Use the context viewer to observe where the Limits property is added.
That might help you narrow in on how to specify the property path to
retrieve the value.
If in your code, you see the extra results in the context viewer, then the
problem lies in how you're trying to retrieve the property. If the extra
results aren't there, then something is wrong in how you're specifying them,
most likely a problem with the AddExtraResult call itself.
One other thing to check... its hard to tell from the code you posted... but
make sure you're calling AddExtraResult on the correct execution object and
that you're calling AddExtraResult ~before~ executing the step you want the
result to show up for. Another programmer here made the mistake of assuming
he could call AddExtraResult ~after~ the step executed and TestStand would
"back fill" previously executed steps. Thats not the case. Also, another
mistake he made was expecting the extra results to appear for steps that did
not contain the original step properties. For example, a string comparison
step doesn't have a "Step.Limits.High" property, so if this property is
called out explicitly in AddExtraResult, then the extra result won't appear
in the string comparison's ResultList entry. Thats why you should simply
specify "Step.Limits" to AddExtraResul so the Limits container (whose
contents vary depending on the step type) will get copied to the ResultList
regardless of the step type.
I call AddExtraResult at the beginning of my process model, not in a UI
message handler, so there may be some gotcha from calling it that way. If
all else fails, try adding the AddExtraResult near the beginning of your
process model and see if the extra results appear in each step's ResultList.
Good luck,
Bob Rafuse
Etec Inc.
[Attachment DebugExtraResults.seq, see below]
Attachments:
DebugExtraResults.seq 20 KB -
How to Implement KFF Range (Low and High) in query find form in oracle apps
Hi,
Please provide some sample script for using KFF range LOV (Low and High) in one of the query find form in Oracle apps R12.
I need to customize one of the standard form and add this range functionality for that search form.
Thanks,
PrasannaYuvaraaj,
Your request is unique to the Oracle Enterprise Business Suite (EBS). Please post your question in the General EBS Discussion forum. If you have a general Forms question, by all means, ask it here! ;-)
Craig... -
Hellow!
I use Audigy2 Value for a long time but never had this question in my mind. Now i have to make music arrangement of several songs and mix a lot of tracks in Sonar, so i extremly need to hear "true" frequencies of my tracks in monitors while mixing. And the question is - what the right position of Low and High sliders in the Audigy 2 Mixer to archi've "orriginal" sound, without any frequency disbalance? (i usually move then from 50% to 00% and, of course, it's not the right way). Heeeelp, pleeeease!For all the equaliser sliders, the middle position of the slider is the neutral one. Above that, the freqv is accentuated, under that, the freqv is attenuated.
The Creative marking in % is a unfortunate one, but 50% is the position that would be neutral. -
I want to get rid of a book in the iBooks "Purchased" collection, but when I touch the Edit button and select the book and then touch the Delete button, then the "Delete this copy" seletion, nothing happens. How do I delete the book from the collection?
The Cloud by the song indicates that is is an iTunes purchase but it is not downloaded on the iPod. If you only want download iTunes purchases to show in the Music app go to Settings>itunes and pp Store and turn off Show aLL.
-
Was skiing with a lifeproof on and my phone did not get wet. On the ride back my phone was struggling to send/receive messages and had trouble opening apps. The screen froze and I hit the sleep button; since then, it has not turned on. Any suggestions on what to do?
It probably got too cold and shut down. Warm it to room temperature, then hold the HOME and SLEEP buttons at the same time until an Apple logo appears.
-
Selection Screen - Date and Time
Hi,
I have given a selection screen where the user needs to key in the input in the following format
dd.mm.yyyy hh:mm:ss.
Reason is that the database fetching these elements accepts only in this criteria.
Now as they look into automating this program, they would want to automatically take the current system date and time - 24 hours .
How do I achieve this in the above format? If this is not possible, let me know if i can make the selection screen with normal sap date format and convert it to the above format on passing to the select statement.
Regards
SamHi Sam,
See this. Is this your requirement.
With this we are able to get Current time-stamp to selection parameter.
REPORT ZTEST.
DATA: L_TS TYPE TZNTSTMPS,
L_TS_C TYPE CHAR14.
PARAMETERS:
P_TMSTMP TYPE TMSTMP OBLIGATORY MEMORY ID TEST.
INITIALIZATION.
GET TIME STAMP FIELD L_TS.
MOVE L_TS TO L_TS_C.
SET PARAMETER ID 'TEST' FIELD L_TS_C.
The output is
Jogeswara Rao K -
Selection-Screen Parameter and select option
Hi
I had a very small and silly problem , i have a selection screen in which i had one select-options and another parameter .
when i define both variable as select option i get output but if i define plant as parameter i dont get any output, .the code .
SELECTION-SCREEN : BEGIN OF BLOCK s_screen WITH FRAME TITLE text-001.
SELECT-OPTIONS: s_matnr FOR plaf-matnr.", " OBLIGATORY,
PARAMETERS: s_werks like plaf-pwwrk. " , " OBLIGATORY.
SELECTION-SCREEN: END OF BLOCK s_screen.
in this code when
i enter material number i dont get output .
i enter plant the i get output
SELECT afko~aufnr
afko~gamng
afko~plnbez
afpo~dwerk
afpo~psmng
afpo~matnr
INTO CORRESPONDING FIELDS OF TABLE i_afko
FROM afko INNER JOIN
afpo ON afpoaufnr = afkoaufnr
WHERE afpo~dwerk = s_werks
and afpo~matnr IN s_matnr
AND afpo~elikz = space.
regards
answers will be definately awarded pointsHi
When you use the plant in select-option, your code should be:
WHERE afpo~dwerk IN s_werks
and afpo~matnr IN s_matnr
if it's parameter:
WHERE afpo~dwerk = s_werks
and afpo~matnr IN s_matnr
Are u sayng in the first case you get the data and in the second one you don't?
Max -
PNP and Selection Screen 900 and Authorization
We have used the combination of logical db PNP with selection screen 900 to write a few custom payroll reports. We noticed right away that this combination seems to ignore HR authorizations. Meaning, someone could read payroll results for employees they are not authorized to see. We had to add our own authorization checks.
Am I missing something or is something wrong with the 900 selection screen?Hi Kenneth,
The 900 selection screen is for evaluation of Payroll Results. The system checks whether the user who started the evaluation has the correct authorization for this evaluation. Since the data retrieval is from the Payroll Results and not Master data the regular Authorization checks might not be relevant here. Even if the User has no authorization to view the Employee's Master data, he/she might still be able to view the Payroll results via this selection screen if he /she has the evaluation authorization. You are probably right in having to put in your own authorization checks. I hope I am not wrong.
Regards,
Suresh Datti
Message was edited by: Suresh Datti -
Selection screen - month and year
Hi friends,
I have a selection screen where I need to have two fields one for Period(month) and the other for Fiscal year. So I used
parameters : p_lfmon like mbewh-lfmon.
parameters : p_lfgja like mbewh-lfgja.
My requirement is when I execute the program I want to see the current period(08) and Year(2006) in these two fields. And also I was wondering if we can add the input help F4 for these two fields as they dont have one right now.
Finally if I want to compare the these two fields month and year with a field in normal date format (08/25/2006), what is the easiest way to do that.
Waiting for replies. Especially from Rich. ThanksIf you need to default the current fiscal period, then you can do this.
report zrich_0001.
data: datum type sy-datum value '20060806'.
parameters: p_spbup type spbup .
initialization.
data: xgjahr type bkpf-gjahr.
data: xpoper type t009b-poper.
call function 'FI_PERIOD_DETERMINE'
exporting
i_budat = sy-datum
i_bukrs = '0010'
importing
e_gjahr = xgjahr
e_poper = xpoper.
concatenate xgjahr xpoper+1(2) into p_spbup.
start-of-selection.
if datum+0(6) = p_spbup.
write:/ datum, 'is in period', p_spbup.
endif.
Regards,
Rich Heilman
Maybe you are looking for
-
Loss of sending email using WIFI
As of this morning 8-20-08, after updating to 2.02, I no longer am able to send emails using my own wireless network. Previously this was no problem. Neither Fido or Apple have any idea of what I am talking about. Fido washed their hands as they do n
-
How do I assign an app to a specific display space in Mavericks.
According to Apple's page on multiple displays in Mavericks ( http://support.apple.com/kb/HT5891 ) it should be an available option when right-clicking on an applicaiont from the dock. I have used this since I upgraded to Mavericks in October but som
-
How to set Environment Settings for J2EE?
hi i don't know java but know a little vb6 i would like make and compile this: http://java.sun.com/developer/technicalArticles/peer/ i downloaded all components... but can't figure out how to do: Table 1: Environment Settings for Compiling and Runnin
-
Trigger Workflow when IDOC_INPUT_ORDERS FM
Hi, When there is an error in IDOC excution using FM "IDOC_INPUT_ORDERS', I have to send a mail to idoc Partner. Please let me know how to do it. Thanks and Regards Ravi
-
I was wondering what everyones thoughts were on vShield whether this is on its way out? Replaced by NSX?