Invoke node XY graph

I have an array that is going to a XY Graph indicator. But I have to perform a certain test at 4 different temperatures, so I need a loop, but I want to save each plot in a file. So I found out that i can use the invoke node and select export image. But then I dont know how to finish the wiring to make it work. I am going to attach the idea of what im trying to do. From the VI i attached there is a bundle that has two 1D array inputs, (they are not shown in the attachment) and then an ouptut cluster of 2 elements. Now since I need 4 plots, I need to save each plot everytime 1 temperature test is done...if i do not do this by the end of the test, at the 4th temp , that is the graph that i will be getting, the other 3 are gone or overlapping
Thanks for your help
Josef
Attachments:
invoke node.vi ‏11 KB

Josef,
I’m a little confused by your question as well. However, I think the only thing you are asking for is how to keep the images from overwriting each other. This can be done by programmatically changing the input of the Path in the invoke node every time you have a new dataset.
Charlie M. CLD

Similar Messages

  • Frontpanel opened by Invoke Node blocks other FP

    Hello,
    In a project I am working on I would like to open and close a frontpanel displaying a few plots from a different VI. I have managed to create the Visualisation VI and am passing references to the Indicators and the VI itself on to the next block. I can open the FP by using an Invoke Node on the VI ref, but then I can only interact with the newly opened VI. To get back I have to close it by hitting X, I would prefer it if I could just have it running in the background or minimized once I click on my "main" Vi again. I have attached the required VIs.
    Solved!
    Go to Solution.
    Attachments:
    FP_Open_plots.zip ‏63 KB

    Hi,
    I can't see your code as I haven't upgraded to 2014 yet (shame on me ). Here is a Main VI that opens a Graph VI in two ways:
    1. Without running it, just by FP.Open. The main VI remains responsive. This is not really recommended but I think it was what you meant to do.
    2. (enable disabled diagram): by running the VI using the Run VI invoke node. In this way the Graph VI is called dynamically and the Main VI doesn't wait until it's done to continue.
    Good luck,
    Danielle
    "Wisdom comes from experience. Experience is often a result of lack of wisdom.”
    ― Terry Pratchett
    Attachments:
    Main VI.vi ‏11 KB
    Graph VI.vi ‏33 KB

  • Reinitialize to defaults using invoke node?

    I've read about this function in a few other threads, but can't figure out how to use the invoke node for that purpose.  How can I, with the push of a button while running my VI, reinitialize all values to defaults and clear all graphs?  Does anyone have an example they can show?

    Here's a quick example. Note that for charts you should also clear the history if so desired.
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    defaults.vi ‏25 KB

  • "Error 7 occurred at Invoke Node..." when attempting to open .vi for editing

    I am attempting to open a vi for editing, and instead the vi is attempting to execute.  I get the error:
     "Error 7 occurred at Invoke Node in BuildTargetBuildSpecification.vi->BuildXFS.vi"    
    Possible reason(s):   LabVIEW:  File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on Linux. Verify that the path is correct using the command prompt or file explorer.
    Method Name: Project: Open
    When I close the Error Message dialog, Labview terminates.

    Hi R.Jay,
    Error 7 generally occurs when trying to create an executable when there is an extra instance of a top-level vi.  You may need to remove the file as a support file (but leave it as the top level vi).
    Are you trying to run an executable that has already been created?  Unless you have already built an executable, it should not automatically run when opened.  Also, was it built in a previous version of LabVIEW?  Sometimes this error can be seen when you upgrade to a newer version without compiling.
    Regards,
    Lauren
    Applications Engineering
    National Instruments

  • Is it better to use Invoke nodes or property nodes to set/get control values?

    I have a series of VI's that run in parallel, each to manage different functions- pumping, sensing, a fluid flow model, an experiment generator/runner.
    These need to exchange data, which I am currently doing using invoke nodes (that are all in subVIs), using methods "Set control value" and "Get control value". I find that every now and then (perhaps 1% of the time) the data isn't exchanged correctly and therefore the system doesn't work. I can imagine how "set" could go wrong if they happen simultaneously, and can devise ways of preventing this. However, the "Get" method suffers from the same problem. This is a major problem, because I want to leave it running for several hours.
    I could in
    principle achieve the same thing using property nodes and find myself wondering if this might be more reliable. But I don't want to change over only to find it makes no difference!
    Can anyone advise?

    You can use some kind of syncronization such as queues, occurances, or notifiers but I think the easiest way would be to create and action engine. This was only one action can execute at a time avoiding a "race condition". Possibly a write action and a read action might help. You also can add queues or notifiers into this concept. hope this helps.
    BJD1613
    Lead Test Tools Development Engineer
    Philips Respironics
    Certified LV Architect / Instructor

  • Excel ActiveX invoke nodes are broken

    I am using LabVIEW 2007.  We are using a VI that runs on most of the PC's in our facility however on some the "invoke node" related to Excel functions don't operate. They are broken and the VIs won't run.  We get errors that the "Invoke Node: contains unwired ro bad terminals".  When going to select methods or properties not all of the properties are shown as seen on the functional PCs. Some of the properties are missing from the selection menus, thus making it incompatible.
    Has anyone seen this problem and a solution?
    Thanks
    Manliff,

    What about separating the compiled code from the source?  I recognize that this will only work in LV2010, but I expect that that will prevent the compiler from breaking activeX code that depends on a different version than the local one...
    Testing this idea is on my to-do-list, but I was wondering if anyone has tried it already.
    -Barrett
    CLD

  • Strange behaviour with ActiveX invoke node and Excel

    I want to send a table of numbers from LV50.1f to Excel97. After getting a
    reg to Excel8.Application I retrieve the Workbooks property, Invoke Item to
    select a certain Workbook reference, retrieve the Worksheets collection
    reference, Invoke Item and then get a reference to WORKBOOKS again.
    Strangely, there is an example code from the NI web site that does exactly
    the same, but in the last step a variant is returned in stead of a
    reference, which is converted using Variant to G to a Worksheet reference.
    when I copied that last invoke node to my VI I also had a variant returned,
    so on one diagram I had to invoke nodes connected to the same sources, one
    returning a ref, the other returning a variant!
    Disco
    nnecting the sources to my Invoke node and rewiring gave no change.
    Also type casting the ref to workbooks to a worksheets ref, didn't work - I
    get errors in the following property node that retrieves a Range - which
    exists in Worksheet, but not in Workbooks.
    Appearantly, LV gets the returned type mixed up sometimes, and there is no
    way to fix it other then copying a invoke node from another diagram?
    Finally I got it working though, but this behaviour puzzles me. Contrary to
    the example from NI, I now managed to send a table (2d array of strings) in
    one call to Excel (don;t need to loop over cells or columns).
    PS
    I used to do the same using DDE but ranges are different for each language
    version of Excel (i.e. R1C1 for English and R1K1 for Dutch), so my VI's need
    to know the language of Excel. Also with NT and Win98, getting a DDE
    connection often hangs LV. But a big progress has been made - now I need
    different VI's for each version of Excel!!!
    Ferry Toth
    Enraf BV, The Netherlan
    ds

    Hi Enric,
    Can you try your queries again using the new release of DB XML? It contains some improvements in this area.
    http://www.oracle.com/technology/software/products/berkeley-db/xml/index.html
    John

  • ActiveX Object Creation method to pass to an Invoke Node

    Hi!
    I'm trying to optimize the way in which I use MathCAD from LabVIEW.  One of my VIs is having really poor performance in terms of execution speed and memory usage.
    My VI converts a 2D LabVIEW array of doubles into a 2d Mathcad matrix and puts that matrix into a Mathcad worksheet.  The issue is that you do not just pass the 2d array of doubles into the SetValue invoke node as a variant.  You have to create a Mathcad.MatrixValue object, and then pass the object to the SetValue invoke node.
    Here is the example code provided in the Mathcad developers manual:
    SetElement Method
    var m = CreateObject("Mathcad.MatrixValue");
    for(row = 49; row >=
    0; --row)
    for(col = 9; col >= 0;
    --col)
    var val = row + col;
    m.SetElement(row, col, val);
    Here is my implimentation in LabVIEW:
    Here is my SubVI
     Here is my main VI:
    My SubVI is running out of memory and throwing the following error:
     Exception occured in mplrun: Exception of type 'System.OutOfMemoryException' was thrown. in NL SubVIs Library.lvlib:Convert LabVIEW 2d Array to MathCAD Variant Matrix (SubVI).vi->test.vi
    It doesn't always throw the error.  When I watch the memory consumption of LabVIEW it goes up to about 250k and then drops to 90k and slowly builds back up to 250k.  Initialy starting the code takes awhile too on my computer.  From start of VI until first loop iteration it is about 20 seconds, and then about 150-250ms after that.  Not very good performance.
    Any advice on how to optimize this code would be appreciated.  I'm not really sure when I should close some of these references.  I tried closing the reference in my converting SubVI, but I guess that destroys it so MathCAD can't use it.
    I'm in LabVIEW 2009.  Any help is appreciated. 
    Thanks for your time and input!
    -Nic

    I'm not sure this will solve your problems but it should help.  You need to close ALL of your references to Mathcad objects when you're done using them.  That means you need to close the reference to the Mathcad MatrixValue after you pass it to Mathcad (to do this you'll need to convert it back from a variant, or pass the reference directly out of your subVI), and you should also close the reference to the matrix that you get back after you've converted it to a LabVIEW array.  Otherwise you'll continuously allocate more and more memory rather than allowing it to be reused.
    Less importantly, you should also close your references to IMathcadWorksheets and IMathcadWorksheet (but since you only open them once it's not causing your memory problems).

  • Error 6 at Invoke Node in Dist Send Result File to RT.vi-- Bu​ild Applicaito​n.vi

    I am using cFP 2000 RT in my application. When I build exe and download the application to the cFP 2000 RT, I get "Error 6 occured in Invoke Node in Dist Send Result File To RT.vi--> Build Application.vi"
    The steps followed.
    1. In the LabVIEW 7.0 Main Panel, Select the execution target as RT Target.
    2. Tools --> Build Application or Shared Library. In the Target Tab the destination directory is selected as \\xxx.xxx.xxx.xxx\c\ni-rt\startup automatically.
    3. In the SOurce file tab, select the Top level VI.
    4. Press Build to make the executable of the application. The application is built and at the end the error message is poped up. (see the attached file)
    Software Configuratio
    n:
    1. LabVIEW 7.0
    2. Field Point 4.0
    3. LabVIEW RT 7.0
    Help me solve this problem. Thanks in advance.
    Attachments:
    Error_Message_and_RT_Info.bmp ‏313 KB

    This is most likely coming from the specific file it mentions in the error, Dist Send Result File To RT.vi. The error 6 means the file can't be found. One thing to try first is to add this VI as a Dynamic VI in Application Builder. Another option is to change the path that this VI is invoked from, or is not called by an Invoke Node at all.
    I hope this helps, feel free to contact support if the problem continues.
    Regards,
    Robert Jackson
    Application Engineer

  • Build error after upgrading from 8.2.1 to 8.5 "Error 1055 occurred at Invoke Node..."

    After upgrading to 8.5, I'm getting the following error when trying to build an EXE:
    Visit the Request Support page at ni.com/ask to learn more about resolving this problem. Use the following information as a reference:
    Error 1055 occurred at Invoke Node in AB_Source_Library.lvclass:Close_Reference.vi->AB_Build.lvclass:Copy_Files.vi->AB_Application.lvclass:Copy_Files.vi->AB_Build.lvclass:Build.vi->AB_EXE.lvclass:Build.vi->AB_Engine_Build.vi->AB_Build_Invoke.vi->AB_Build_Invoke.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  Object reference is invalid.
    I have been building this application for both Windows and Mac OS, and I even get the same error when building the .app on an Intel Mac.
    Things that I've already tried:
    * Mass-compiling all my code
    * Created the project from scratch
    * Enabled each panel of the "diagram disable structure" one at a time and compiled again
    Any ideas?

    Hi Travis,
    Ben’s advice if definitely the best place to start. Error 1055 is a very general LabVIEW error for “Object reference is invalid.” The cause is usually a bad install where important LabVIEW function aren’t placed in the right directory or aren’t installed at all.
    Charlie M. CLD

  • Error 1003 occurred at Invoke Node

    Good morning.
    I work with LW8.5 and created with the following architecture:
    There is main.vi on the links at the user's calls and runs the other VI.
    That is, not directly, these are not included in the VI block diagram main.vi.
    In the development of a happening in normal mode, all dynamically called VI,
    But once I make EXE, when you try to call the dynamic VI error 1003.
    Error 1003 occurred at Invoke Node in Main.vi
    Possible reason (s):
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the VI in LabVIEW using File>> Open and verify that it is runnable.
    VI Path: C: \ Shaikov \ Labwiev \ builds \ NSIAES \ Initialsettings \ Initialsettings.vi
    Show you how to act?
    Thank you.

    Hello margasan.
    In my Projects I use to pass more dynamic and VI classes.
    In the attached file - an example of my project:
    In the main folder is a folder UpperClass, it is the parent class and child classes and HeirClass.lvclass Heir2Class.lvclass are organized into folders respectively Plugin1 and Plugin2, and these Classes inherit from the parent one and the same WI - UpperClassTest.vi. Plus, this Plugin1 has two, independent from the others, but related classes. A block diagram for an object placed Core.vi UpperClass.
    So, here, if you take EXE, making llb files and run them from start VI for each of the Plugin, then everything works OK.
    But as soon as I on the block diagram of a Plugin will put any object UpperClass, or one of its nasalednikov, there arises a familiar ERROR 1003. Prompt, plc, margasan I get rid of it in this case?
    Attachments:
    Example.zip ‏1481 KB

  • Error 8 occurred at Invoke Node in AB_EXE.lvc​lass:Build​.vi- AB_En​gine_Build​.vi- AB_Bu​ild_Invoke​.vi- AB_Bu​ild_Invoke​.vi.ProxyC​aller

    Hi there,
    Hope someone can help me.  I recently upgraded to LV 8.5 and am having a problem building a .exe which has a subvi in it that opens in a new dialog window.  When I try to build this I get the following error:
    Error 8 occurred at Invoke Node in AB_EXE.lvclass:Build.vi->AB_Engine_Build.vi->AB_Bu​ild_Invoke.vi->AB_Build_Invoke.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  File permission error. You do not have the correct permissions for the file.
    =========================
    NI-488:  DMA hardware error detected.
    Method Name: Build:Application
    I have built the .exe with the same subVi but without opening it in a dialog window and it works fine., so the problem seems to be linked to the inclusion of the dialog window.
    Any advice greatly appreciated
    Regards
    Tadhg

    UPDATe:  I can get the .exe to build but now I get an error when I run teh .exe which is shown in the picture attached.
    Attachments:
    error screen1.JPG ‏122 KB

  • Error 8 occurred at Invoke Node in AB_EXE.lvclass:Build.vi- AB_Build.lvclass:Bui

    During software build to make exe file, I got the following error message:
    Error 8 occurred at Invoke Node in AB_EXE.lvclass:Build.vi->AB_Build.lvclass:Build_from_Wizard.vi->AB_UI_FRAMEWORK.vi->AB_Item_OnDoProperties.vi->AB_Item_OnDoProperties.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  File permission error. You do not have the correct permissions for the file.
    =========================
    NI-488:  DMA hardware error detected.
    Method Name: Build:Application
    The vi was working fine before the build. It just access some text files and creates some excel files. No hardware is involved. See if anybody know how to solve this problem. Thanks.

    I am using LabVIEW 2014 and have been getting this error randomly, but fairly consistently on a recent build. I searched all over and could not find a solution that worked. However, just through trial and error I discovered that the problem is related to SSE2 Optimization in the Advanced properties window. I can consistently cause this error by enabling this feature and consistently compile successfully when it is disabled. Try turning this feature off and see if it solves the problem.
    ...UPDATE: After closing and re-opening LabVIEW this error came back, and did not seem to be affected by the SSE2 option. Not that it isn't related, but perhaps not the silver bullet I thought it was.
    I also got the error to go away sometimes when I compiled the EXE while the main program VI was open, whereas it gave the error most of the time when no VIs were open...again, nothing seems to consistently solve the problem...there is definitely some kind of bug in the appllication builder, and it seems like there are a lot of people that have been struggling with this for a long time (as far back as LV 8)...hopefully NI eventually finds this bug and squashes it!..although, I doubt that anybody at NI is even looking for it...

  • Error 7 occurred at Invoke Node in AB_EXE.lvclass

    I get the "Error 7 occurred at Invoke Node in AB_EXE.lvclass" error when trying to build an executable in Labview 8.5.1.  I can run the application without any errors but when I try to build the executable, I get the error.  I have tried a mass compile of the project, tried ctrl + shift + run on the top level vi, and tried to mass compile the folder where the project is located and nothing seems to help. I have also looked at the project dependencies for conflicts and found none.  I have made a new project and tried to build an executable from this same code without any luck.  How can I get this to build an executable?
    The exact error is:
    Error 7 occurred at Invoke Node in AB_EXE.lvclass:Build.vi->AB_Engine_Build.vi->AB_Build_Invoke.vi->AB_Build_Invoke.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on Linux. Verify that the path is correct using the command prompt or file explorer.
    =========================
    NI-488:  Nonexistent GPIB interface.
    Method Name: Build:Application

    Are you using the Report Generation Toolkit?  A lot of error 7's during builds seem to be related to this toolkit.  Any dynamically called VI's?
    Take a look here and here.
    Also search the forums for "error 7" and you'll find some other threads related to error 7 and the application builder.

  • Error 7 occurred at Invoke Node in Dist read linkages.v​i- Dist Cmp Settings to Disk Hier.vi- B​uild Applicatio​n.vi

    Error 7 occurred at Invoke Node in Dist read linkages.vi->Dist Cmp Settings to Disk Hier.vi->Build Application.vi????
    Hi I do not understand how to resolve this nagging problem.
    I run the program in the development time and it all goes smoothly.
    However when i wanted to build the program. I often run into this problem.
    How to resolve it?
    Clement

    Hey Clement,
    Which version of LabVIEW are you using? There some knowledgebases out there that address the issue. Click here for the first KB or here for the second one. Hopefully these would help.
    Regards,
    Chetan K
    Application Engineer
    National Instruments

Maybe you are looking for

  • Can SSIS be used to pick up files dynamically from an FTP folder?

    I get 4 files dumped into an FTP folder each day.  Each comes in with a date, in this format: '20140320' & the filename, which is always the same convention for these four files.  Can I run SSIS on a daily basis, like at 9AM, to scan through the file

  • Dynamic runtime reporting

    Hello, We are planning to develop an asp.net web application where we require a facility that the users may select a number of required fields at runtime and then can view a report in crystal reports for that fields only. In terms of explanation, the

  • Help! camera movements changing b/w keyframes

    Please help!  I'm making a kinetic type video and the camera movements change in between the keyframes I set up.  For example; if I want the camera to just shift to the right, I copy the frame position, and then change the X axis.  When I switch betw

  • Importing Adobe Illustrator pages to Muse

    I built all my pages in Adobe Illustrator. I have many masked png images on my pages. Am I going to have to place them all again in Muse?

  • OEM 9i - Login Once, then can't login again

    I have installed Oracle 9i, Personal installation on a Windows XP Pro machine. After setting the new password for SYSTEM and SYS during setup, I was able to log in to my database (PRACTICE) one time. I close OEM and start it again, and the login scre