Iomega StorCenter ix4-200d replace all disks

REPLACED DISKS: 4 Hard Drive SEAGATE 1 TB with code ST31000520AS.
Before the replacement, had carried out the firmware upgrade for CC38 as executable: DriveFWUpdater-1.8.exe
Successfully finalized.
After the replacement of 4 discs, the procedure would make a boot by USB to reinstall the OS, right?
But when holding the reset for more than 60 seconds, does not appear on the LCD panel USB image >> Network, does not find the boot from USB.
Is there any other procedure?
Thanks.
Solved!
Go to Solution.

Hello estaile
The "DriveFWUpdater-1.8.exe" utility is just for updating the Seagate firmware to cc38 in the ix4-200d / ix4-200d CE.
to replace all the disks you would need to follow the disk upgrade guide here.  Basically if you still have at least one original disk with the Lifeline OS firmware, then you can boot the unit with that disk and 1-3 blank disks, after booting the unit will copy the firmware over.  if the web interface requests overwrite,  allow the overwrite.  after that has finished you can power down, install the 4th disk and boot up the unit.  the previously installed disk(s) would then be able to copy the firmware over to the last disk.
If you do not have any original disks with the firmware intact, it will limit your options as some of the legacy firmware imagers are no longer available.  I recommend contacting LenovoEMC support in your region at that point to see what options might be available.
LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
US and Canada: https://lenovo-na-en.custhelp.com/
Latin America and Mexico: https://lenovo-la-es.custhelp.com/
EU: https://lenovo-eu-en.custhelp.com/
India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
http://support.lenovoemc.com/

Similar Messages

  • Iomega StorCenter ix4-200d iSCSI performance

    Hi there, just looking for some help here, we have an Iomega StorCenter ix4-200d device that was not in use and I tried to make a drive for storing media files and moving them from the file server. I have created an iSCSI disk and connected to a Windows 2008R2 using an iSCSI Initiator, the Iomega box comes with two network interfaces that were previously bonded, the connection was quick and easy to setup, the problem that I am having is performance. When transferring small file/s the transfer is quick and effective, but if the file/s pass more than 1GB windows explorer crashes and the OS get frozen, I have been monitoring the disk use and is horribly high when transferring those files, taking more than 10min for a 1.5GB to transfer, the LAN is 1GB speed. I read about creating specific VLANS only for iSCSI transfers, but we did not have that before and the drive was previously used as iSCSI backup solution, before another solution now in place replaced it Any help or thoughts are more than welcome Juan

    GUS_Lenovo, Really helpful your coment, please can someone else let us know if it is having this problem. The setup is very simple a VMware ESXi 5.5 virtual machine, OS 2008R2, connected using passtrough native windows iSCSI initiator to an external Iomega StorCenter ix4-200d drive. I disconnected the target from the troubled server and connected the iSCSI disk to a test server, same setup VMware 2008R2 connected to the pysical iSCSI uing the windows native initiator, no roles on it. I double checked that only the test server was connected into it, same symptom, transfers files up to 500MB are quick and effective, if the file/s to transfer pass 1GB or more the transfer halts and the explorer process on the VM crashes, not very effective for now. Bandwith?? any help very much appreciated

  • User quota update bug on Iomega StorCenter ix4-200d - 2.1.42.189​67

    Hi everyone,
    my device is Iomega StorCenter ix4-200d running firmware version 2.1.42.18967
    Last week user X on my device exceeded his personal folder's default quota (2 GB): I told him to move exceeding data away from the storage device and he did so.
    Now he only has 300 MB under his folder, but the the device's web interface is still complaining about userX using 50 GB of space and therefore exceeding his quota. Furthermore, user X is not allowed to put more data into his personal folder, even if only stores 300 MB of data...
    I tried the following solutions:
    reboot the device
    disabled quota on user X's personal folder and then re-enable it again
    but none worked. How can I fix the issue?
    Any help/hint would be appreciated. Thanks in advance

    Hello sanzso
    I highly recommend you contact LenovoEMC PX12 support in your region regarding this issue. 
    a quick suggestions though.  If media server is enabled, in some situations there can be an issue causing a data usage mis-match.  Usually this would only show the  "others" listing to show as having a strange usage level.
    To correct this, media server would need to be turned off, copy the share data to a new share or external storage device, delete the existing share(s) then restore the data to the new share(s).
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Replacement drive for IOMEGA StorCenter ix4-200d

    Hi
    One of my four Seagate ST32000542AS 2TB drives in my NAS needs to be replaced, but it seems that that drive has been discontinued.
    Which compatible drive should I choose instead?
    Soren

    It looks like the ST2000VN000 is 5900 RPM, which would work. You could also try ST2000DL003, ST2000VM003, ST2000VX002, or ST2000DL001.
    Have questions and need answers?
    Search the database for answers to FAQ's, software/driver downloads, tutorials, news, features and more!
    LenovoEMC Support & Downloads
    LenovoEMC North America Support Contact Page

  • Iomega Storcenter ix4-300d stuck at 95% after firmware upgrade

    Hi,
    I upgraded my device after I got an email that there is a new firmware:
    An update to version 3.2.10.30101 of the Iomega StorCenter ix4-200d software is now available
    I installed the update but now it is stuck at 95% after rebooting.
    Never had any problem before the firmware upgrade. 
    Any advice?

    Hello BelgianTomas
    I recommend that you first power down the unit if the unit has not completed the boot process.  Then re-seat all disks and try booting the unit again.  Please do not try to access the web interface until the power led is solid white.
    Next would be to try moving the internal disks to different bays to see if a different drive order wil allow the unit to boot. 
    If that does not help, LenovoEMC suppor should be contacted for more advanced options.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Iomega ix4-200d Four drives in RAID 5 Lost Data

    Hi,
    I've Iomega StorCenter ix4-200d with firmware version 2.1.46.30093. The unit has four 1TB drives setup as RAID 5.
    I've been having intermittent issues with drive 4 and IOmega device has been automatically reconstructing the protection in last few weeks. Recently drive 1 showed similar issue and now the whole data became invisible.
    After Login to the device I see this message:
    4 new drives with existing data have been added to your Iomega StorCenter device.
    The Iomega StorCenter device failed and some data loss may have occurred.
    On the Disks page, I see the four disk and If I hover over one of the disk it display this pop help message:
    Disk has been replaced with a disk containing data from another system.
    On one of the page I got this message:
    Disk Overwite Authorization:
    A disk with existing data has been inserted.
    Note that using this disk will permanently destroy all of its previous contents.
    Check this box to authorize overwriting the disk.
    I have not done the overwriting to avoid any data loss. The unit is out of warranty and I need data recovery.
    So far I've found these options online. Just would like to know the your experience, data recovery success and $$ amount you paid for the tool / service for recovery.
    a. http://www.diydatarecovery.nl/irecover.htm - $70 tool
    b. http://freedatarecovery.us/ - Service
    c. http://www.angeldatarecovery.com/raid5-data-recove​ry/ - Service
    d. http://www.krollontrack.com/data-recovery/recovery​-software/windows/ - $499 tool
    e. http://www.freeraidrecovery.com/library/raid5-reco​very.aspx - Free tool
    f. https://www.runtime.org/raid.htm - $99 Tool
    g. http://www.retrodata.co.uk/data-recovery-services/​nas-data-recovery/iomega-data-recovery/ - Service
    h. http://www.drivesaversdatarecovery.com/devices-sup​ported/raid-data-recovery/ - Service
    Please advice.

     Hello svfm
    As mentioned in another thread, UFS Explorer has been fairly successful, however I have not seen quite as much results from other applications.   iRecover would be the next recommended option other than contacting a data recovery provider that can work with RAID systems.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Ix4-200d CE locking up on device restart after FW update to 3.2.10.30101

    I updated the firmware on my iOmega StorCenter ix4-200d CE (4TB) to 3.2.10.30101 last night from 3.2.8.30031. After it uploaded to my NAS, it started to do it's normal shutdown, followed by the power up. Everything was going well until the power up, where it has locked up at 95%. There were no messages at all that came up either via the web interface, or on the LCD screen on the front of the device itself. 
    Has anyone else run in to this problem? Does anyone know of a solution? I have powered it off twice, and turned it back on. I get the same results. 
    Can I maybe load the previous version of the firmware on to a USB key, and install that without using the web interface, or losing any data? 
    EDIT: I should add, that it does show up as connected to my network when I look at the connected devices on my router. Upon seeing that, I decided to see if I could access the drives over my network, and oddly I can. I can access them both from my MacBoook Pro running Mavericks, as well as my PS3 which I use to access the Media Server on my NAS. My TimeMachine back ups are also still going to the NAS, and I can copy files too, and from it. 
    So it appears it has fully restarted, but the  device itself on it's LCD screen, the web GUI, and the LenovaEMC Storage Manager keep saying that it is still "restarting", not allowing me to do any managment of the device. 

    Hello SurveyGeek
    If your device did not seem to complete like others did on this forum thread, please try the following.
    - Backup any critical data from the unit if another copy does not already exist. 
    - Power down the unit swap the first and last hard drives so they are in opposite bays and also re-seat the remaining disks.
    - Reconnect power cable and allow unit to boot.  you should close all previous web sessions to help speed up the boot process.
    - If the issue persists please contact LenovoEMC support to review the issue further. 
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • What harddrives are approved for use with ix4-200d?

    Hi,
    I found an article on the Lenovo site for the process of swapping out all 4 hard drives in an ix4-200d, but what I can't find is an article showing the list of approved/recommended hard drives for use with the ix4-200d.  Can anyone point me to such an article?
    My ix4-200d has a 4x500GB configuration (Seagate ST3500412AS drives).  I'd like to swap them for either 2TB or 3TB drives, so I can have one place to store all my raw video, which right now is spread out over three different devices.  Also, if you have any advice or gotchas to look out for when I swap out the drives, I'd love to hear you on that matter.
    Thanks,
    William

    Hello vitorpereira
    In regards to the ix4-200d and ix4-200d CE, Iomega/LenovoEMC never created an approved list of drives.  When a disk failure occured the disk should be replacing with a matching drive if at all possible.  
    When it is not possible to use a matching disk model, a similar disk should be used.  This would be a disk with the same manufacturer, capacity and rotation speed.  
    For the ix4-200d specifically, the units shipped with either a 500GB, 1TB, or 2TB Seagate Barracuda LP (5900rpm) Hepburn disks.  ST3500412AS, ST31000520AS, ST32000542AS
    That is what the ix4-200d units were qualified to use.  Outside of those three specific drive models you will be dealing with hypothetically compatible disk options. 
    The recommendations that Wesley made previously are correct.  You should go though the ix4-300d list find a model that is similar to the stock drive or at least within the capacity limits of the device model.  (ix4--200d is 2TB disks, ix4-200dce is 3TB disks)
    If a different disk models are used in either version of the ix4-200d, it is highly recommended that all disks be eventually replaced with the new model of disk for RAID stability.  to do this, the Capacity Upgrade Guide should be followed.  
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Disk Spindown on ix4-200d fw3.2.10... cloud

    Greetings!
    After many years of dedicated service, a drive in my NAS has failed. These disks are discontinued and unavailable from Iomega/Lenovo, and I can only find reconditioned drives online, which I prefer not to use.
    I took this as an opportunity to upgrade the NAS with 4 new Toshiba DT01ACA300 3TB drives with the understanding that they are not on any 'supported' list for this box.
    All is working well with the exception of one thing. The new drives do not spin down regardless of the setting selected in the green settings. The NAS sits idle for 75% of the day, so it is reasonable to have them spin down.
    I've been tempted to experiment with the linux command start-up procedures, but thought I might first get the insight and opinions of the experts first to help guide me to the correct path.
    I've turned off all services except windows and MAC file access and SSH. I've read that some of the services can prevent spindown from being triggered.
    Console boot shows a call to hdparm that does not set any params. This was true of the original disks as well, so I find myself not understanding the mechanism used to control spindown timing/control.
    I am linux experienced and am comfortable with operating system configurations, so feel free to advise in any configuration adjustments you feel would be helpful.
    Thank You,
    Doug.

    This may not be the information you need, but ... here it is anyway.
    md0_raid1 is the only process writing to the hard drives. 
    There are no reads to md0 even after 10 minutes, so this is strictly a write issue.
    TASK PID TOTAL READ WRITE DIRTY DEVICES
    md0_raid1 644 352 0 352 0 sdc1, sdd1, sda1, sdb1
    displayd 2580 24 0 24 0 dm-1
    pdflush 149 20 0 20 0 dm-1
    cp 5767 15 0 15 0 dm-1
    mdo is the mirror raid set for the firmware/os/apps. I don't see anything amiss.
    root@ix4-200d-Cloud:/# mdadm --detail /dev/md0
    /dev/md0:
    Version : 00.90
    Creation Time : Sat Mar 7 12:00:43 2015
    Raid Level : raid1
    Array Size : 20980800 (20.01 GiB 21.48 GB)
    Used Dev Size : 20980800 (20.01 GiB 21.48 GB)
    Raid Devices : 4
    Total Devices : 4
    Preferred Minor : 0
    Persistence : Superblock is persistent
    Update Time : Fri Mar 20 08:06:01 2015
    State : active
    Active Devices : 4
    Working Devices : 4
    Failed Devices : 0
    Spare Devices : 0
    UUID : 767ed4e1:cde9f6db:b42f99e0:30138ac1
    Events : 0.2731
    Number Major Minor RaidDevice State
    0 8 49 0 active sync /dev/sdd1
    1 8 17 1 active sync /dev/sdb1
    2 8 33 2 active sync /dev/sdc1
    3 8 1 3 active sync /dev/sda1
    root@ix4-200d-Cloud:/#
    md1 is the user raid 5 set. It too looks OK.
    root@ix4-200d-Cloud:/# mdadm --detail /dev/md1
    /dev/md1:
    Version : 01.00
    Creation Time : Mon Mar 16 19:13:20 2015
    Raid Level : raid5
    Array Size : 8727856320 (8323.53 GiB 8937.32 GB)
    Used Dev Size : 5818570880 (5549.02 GiB 5958.22 GB)
    Raid Devices : 4
    Total Devices : 4
    Preferred Minor : 1
    Persistence : Superblock is persistent
    Update Time : Fri Mar 20 07:40:20 2015
    State : clean
    Active Devices : 4
    Working Devices : 4
    Failed Devices : 0
    Spare Devices : 0
    Layout : left-symmetric
    Chunk Size : 64K
    Name : ix4-200d-BO0YMG:1
    UUID : 155ad933:6f88005c:e999c694:06d74f07
    Events : 79
    Number Major Minor RaidDevice State
    0 8 2 0 active sync /dev/sda2
    1 8 18 1 active sync /dev/sdb2
    2 8 34 2 active sync /dev/sdc2
    3 8 50 3 active sync /dev/sdd2
     I'll try to find what files are being written to on md0.
    root@ix4-200d-Cloud:/# df -h
    Filesystem Size Used Avail Use% Mounted on
    rootfs 50M 9.6M 41M 20% /
    /dev/root.old 6.5M 2.1M 4.4M 33% /initrd
    none 50M 9.6M 41M 20% /
    /dev/md0_vg/BFDlv 4.0G 634M 3.2G 17% /boot
    /dev/loop0 593M 539M 55M 91% /mnt/apps
    /dev/loop1 7.5M 2.3M 4.9M 32% /etc
    /dev/loop2 252K 252K 0 100% /oem
    tmpfs 250M 0 250M 0% /mnt/apps/lib/init/rw
    tmpfs 250M 0 250M 0% /dev/shm
    /dev/mapper/md0_vg-vol1
    16G 832M 16G 6% /mnt/system
    /dev/mapper/5bf97fdd_vg-lv5c738722
    8.2T 6.4M 8.2T 1% /mnt/pools/A/A0
    root@ix4-200d-Cloud:/#
     I haven't figured out what the loop filesystems are yet, but loop2 appears to be full (/oem). I have no way of knowing if this is an issue or not.

  • I OMEGA ix4 200d error

    Dear Sir, I am Nagamani from M Damodaran & Associates Chennai. We are Using NAS I OMEGA ix4 200d Model.We are getting the errors in NAS. The Errors are 1. Drive3 is Missing2. Data Production need to be reconstructed These are errors we getting. I swaping the Hard disk and Check it and problem not solved.We getting the Same Problem. I also do it the Factory reset,the problem not solved. I remove all the Hard disk and format the HARD DISK with NTFS File system. After that NAS cant start up. In lCD Display USB flash device only shows. Kindly support me and solve the issue. Our device out of Warranty I also do it  the Following steps: This utility updates the firmware on Seagate hard drives installed in StorCenter ix2-200 and ix4-200d devices. The updater is recommended for HDDs larger than 500GB capacity that have CC37 or lower firmware and 500GB HDDs with firmware versions lower than CC37. It updates the firmware on these HDDs and provides performance improvements for the StorCenter device.You can check the capacity and firmware version of the HDDs installed in your StorCenter by logging into the web interface:If your StorCenter is using Lifeline version 3.x firmware, select Storage > Drive Management > Settings.If your StorCenter is using Lifeline version 2.x firmware, check under Settings > Disks.
    CAUTION: ALWAYS BACK UP YOUR DATA BEFORE PERFORMING A FIRMWARE UPDATE!Follow the install instructions closely. This process should not affect the data on your drives; however, Iomega recommends you backup your data before proceeding! If you have files on the device you want to save, move them to another drive before updating. Perform the following steps to create the bootable update image on your USB flash drive. You will need to use a computer running a Windows operating system.Format a USB flash drive to FAT32:Insert a USB flash drive into a USB port on your PC and make a note of the assigned drive letter.IMPORTANT! The contents of the USB flash drive will be destroyed!From the Start menu, right click on My Computer (or Computer) and choose Manage.In the Computer Management console, in the left column, navigate to Computer Management (Local) > Storage > Disk Management.In the right column, right click on your USB drive and choose Format...You will be warned that the data on the drive will be lost and asked to confirm, choose Yes.In the Format options window, select FAT32 in the File System drop down menu and click on OK.You will be warned again that the data on the drive will be lost and asked to confirm, choose Yes.Allow the formatting process to complete before moving on to the next steps (leave the USB flash drive plugged in).Create the bootable USB flash drive containing the update:Download the update software DriveFWUpdater-1.8.exe onto your desktop.When the download is complete, double click on the saved file DriveFWUpdater-1.8.exe to start the installation wizard.On the initial setup page, click on Next >.On the Choose USB Device page, enter or browse to your USB drive to select it as the destination, then click on Install.When prompted, click on Finish.Safely eject the USB flash drive from your PC.Apply the update to the hard drives in your ix2-200 or ix4-200d:Power off your ix2-200 or ix4-200d.Unplug any external USB devices you may have connected to your ix2-200 or ix4-200d.Insert the bootable USB flash drive with the Updater into a USB port on your ix2-200 or ix4-200d.Press and hold the reset button on the rear panel of the unit.Power on your ix2-200 or x4-200d.Continue holding the reset button while powering on the device.ix4-200d: After about 1 minute, a picture of a USB flash drive will show on the front LCD display. At this point, release the reset button.ix2-200: Hold the reset button until the ix2-200 powers up completely.The ix2-200 or ix4-200d unit will now execute the utility loaded on the flash drive to update the drives in the system. After all drives are updated, the unit will automatically shut down. This should take less than 1 additional minute.After your ix2-200 or ix4-200d powers off, remove the USB flash drive.Power up your ix2-200 or ix4-200d.Verify the firmware version on the installed hard drives:If your device drives are 1TB or 2TB drives (4TB or 8TB total capacity), verify that the drives are updated to version CC38.If your device drives are 500GB (2TB total capacity), verify that the drives are updated to version CC37.You can view the HDD firmware version under:
    Storage > Drive Management > Settings (Lifeline version 3.x), or
    Settings > Disks (Lifeline version 2.x).Click the link below to download your software...  

    nagamani,
    The only option is to flash it, which I understood that you had already tried as part of that set of instructions you posted is for the imager.
    If I am mistaken, you can contact support and request the imager here:
    https://lenovo-na-en.custhelp.com/app/ask/
    I cannot release the imager on these forums.

  • Ix4-200d firmware update

    Is there any way to update the firmware via USB (from a flash drive)?

    Hello esurplusplus
    There is a way to flash the firmware via usb on ix4 units, however this is completely data destructive so it is not considered an update process.
    If you have an ix4-200d I recommend checking the nas-central.org forums, they should have guides on preparing a usb flash drive for firmware imaging.
    If you have an ix4-200d CE that is in warranty or if you are having issues updating to the latest firmware, please contact support as we still have the 3.2.6 imager utility which helps if your device is stuck at an older 3.0.x firmware.
    If you are just trying to load the firmware due to formating all disks, purchasing an empty ix4-200d CE, or replacing all the disks at the same time, I can not say for certain that support would assist with an imager as those situations are handled per case.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Resetting ADMIN password for Iomega storcenter PRO 250D

    I have a 250D PRO Iomega storcenter which I have forgotten the admin password. I still have user id's and pass but that will not let me trouble shoot etc. my unit. I have held the front button for 12 seconds etc., which I thought was the method but it does not seem to be working or else i forgot the default admin credentials. I believe they are ADMINISTRATOR/ADMIN!! Please anyone feel free to correct and direct me. Thanks in advance for the help. Also if anyone knows what the latest although not recent firmware version  etc. is and how to check, I would appreciate it!! Thanks a million in advance!!
    Solved!
    Go to Solution.

    Hi and thx 4 the response. Are we saying that pressing the front button for 12 seconds etc. IS the method to reset the server's administrator's password? It is working just fine, I can reboot it and when I press the button and hold it it shuts off, but will reboot if I press it again!! I just need to reset the administrators password. I have all the restoration disks , so I could go that route after backing up all data but want to exhaust all non destructive methods first!!

  • Iomega StorCenter ix2-200 - Harddrive failure.

    Hi, I own a Iomega ix2-200. It's the 2x2 GB Device with firmware version: 2.1.42.18967A few weeks ago the red-LED started to blink in front of the device.
    I check the Iomega system manager and it says.
    "The Iomega StorCenter device is degraded and data protection is at risk".So I check the log.It says:10/07/2013 8:05 pm Drive number 1 cannot be detected.10/07/2013 8:05 pm Data is available, but a failure has been detected. My question is. How do I know what drive is "Drive number 1" and how do I know what type of drive I need to replace the old one with?I really would prefer if I could fix this problem myself rather than to send the whole device for repairs when it's only a drive that's broken. Thanks for your time // Max B

    Hi Africa13 Yeah they should do fine, are either of your current disks operational?  When you replace the drives, the Iomega software is actually stored on the existing drives, not the enclosures built in memory. So when replacing, it will need a drive with the software on it. You basically replace one drive at a time and then allow the new drive to build. Once its complete, you replace the other and allow it to build then the same way. I had no issues with my two WD 2TB 3.5" SATA-600 IntelliPower 64MB Caviar Red that I put in, so you should be fine. Kind Regards Buckweed

  • Iomega - StorCenter iX2-200 - TUTORIAL

    How do I set up the Airport Extreme so that it works well with the Iomega StorCenter ix2-200. I would not think any tutorial for theAirport settings in which the manual says Iomega.
    Regards,

    My best advise to you would be to return the unit if at all possible. I have had nothing but trouble with mine and iomega support is dreadful.
    Currently on the 2nd unit. Had a hard drive fail on this one 2 weeks ago, they have still not authorised a replacement drive and today the 2nd drive has also failed. Another dead unit.
    Run a mile

  • Removing our AD server / disabling security on ix4-200d

    My organization is in the process of decommisioning our Windows Server 2003 and moving to complete reliance upon our iomega ix4-200d for our file serving solution.
    My understanding is that disalbing AD on the iomega device will remove the existing users and shares that have been synchronized from our Active Directory.
    I'm looking for suggestions about how to recreate the existing AD user accounts once the ix4 is in workgroup mode while causing a minimum amount of disruption to the office -- especially since I obviously don't know the passwords of the existing AD user accounts?

    swgarland wrote:
    Without getting into a discussion of why you would want to remove AD from a network, on the NAS box, you'll need to create local accounts (you won't have a domain anymore).  Then create groups etc, just like you had before and apply the correct rights.  You'll have duplicate accounts for a time period (domain and local).
    PV: Basically, we've retired our Windows Server 2003 in favor of the NAS box and when I finally pull the plug on the Windows box our AD will go away.
    I would create all the accounts FIRST including a new NAS admin account.  Then login to the NAS with the local admin to verify it works BEFORE you disable AD integration.  Once you disable the AD integration, all the domain accounts and groups disappear, and therefore won't work.
    PV:  That's kind of what I gathered, I was just hoping someone else had gone through this before and had suggestions for duplicating the accounts. I guess I will set the accounts up ahead of time and try to figure out a way to make people change the default password I give them.
    Looking at the "Users and Groups" admin applet, however it's not clear to me how to create local users and groups when AD is active. I don't see any interface to add users or groups, only links to "import users and groups from Active Directory" and to "synchronize with Active Directory"?

Maybe you are looking for

  • FIOS internet connection question

    We are getting our FIOS bundle installed this coming Friday (phone, TV, internet) - - My house is 5 years old, and has coax outlet at the TV, and phone jacks in two rooms.  Our home computer is in another bedroom, and it has a phone jack that was wir

  • Is there any way to import a contact list into the mototalk app

    I have the new Mototalk app and I need to import about 350 push to talk contacts into the mototalk contacts. Is there any way that it can be done from a cvs or database file

  • How do I cause a form field to raise its blur event?

    I have a web form that displays an editable pdf document.  When a user clicks a button the form will get validated.  If one of the fields being validated has the focus its value will not get updated when I need to do the validation.  For example, if

  • Poor Quality when Exported for DVD

    Hi, I am creating a dvd of some animations, and the animations are videos of what were originally all vector shapes and text. The videos were originally made with After Effects, at 720x480, NTSC preset. I can export from after effects at full-scale w

  • Manual sorting in album in iPhoto 11 resets itself when I close iPhoto. Any suggestions?

    I'm using iPhoto 11 and am trying to combine photos from three different cameras (so slightly different date/time stamp). I have copied all photos into an album, then sorted by date. Because of variation in date/time I need to sort manually to combin