IPS Load monitoring using SNMP

Since CPU is always 100% now in v6.x/v7.x - is anyway to monitor the system load (reported in IDM/IME) using SNMP?
What counter can be a good indicator for system upgrade that can be monitored using SNMP?

Currently you can not query IPS senor load via SNMP, there is a feature request out for it.
If you want to monitor load right now you can write a script that logs into the sensor and preforms a "show statistics virtual-sensor | i Load"
This is a snapshot, and I believe the GUI provides an average.

Similar Messages

  • Oracle database monitored using SNMP

    Hi guys,
    I have a problem that I can't seem to find the answer too...I tried google-ing, but found only pieces, and can't seem to figure out the big picture...So here goes:
    I am working with my team on a Data Warehouse project, and the entire app is written in PL/SQL and SQL code, running in an Oracle DB. Now, the PO wants to have SNMP monitoring, and in the last few days I looked into how can I achieve this (please note that I have little experience with Oracle, know about SNMP for like 2 days...and I am not sure even if I am posting in the right forum)...
    So after searching online, for an Agent for Oracle i found this website : http://www.oracle.com/technetwork/oem/grid-control/downloads/agentsoft-090381.html ..and I think this is what i need....(can anyone confirm this???)
    Anyway after downloading, and reading the instructions I choose to try the so called *2. Silent installation of the agent* and below are the instructions...
    For silent installation using the extracted agent download zip file, copy the <UNZIPDIR>\windows_x64\response\additional_agent.rsp file to a location on the local machine and modify the Value Unspecified entries accordingly. Invoke the setup.exe by executing:
    +<UNZIP_DIR>\windows_x64\agent\setup.exe -silent -responseFile <location>\additional_agent.rsp+
    So then I started editing the file additional_agent.rsp and everything was going well until I reached the following part:
    #OMS_HOST:<String> OMS host info required to connect to OMS
    #OMS_PORT:<String> OMS port info required to connect to OMS
    #AGENT_REGISTRATION_PASSWORD:<String> Agent Registration Password needed to
    # establish a secure connection to the OMS.
    OMS_HOST=-----
    OMS_PORT=----
    AGENT_REGISTRATION_PASSWORD=----
    I have no idea what to put in the OMS_HOST and OMS_PORT fields...What do they refer to?
    Other mentions Oracle DB is 11.2.0..OS is Windows 7
    Thanks for reading/help :)

    So I talked more with the PO...and the thing is our product is just a small part of a much bigger product...he said : *"we do not need the Oracle Enterprise Manager for monitoring; we are going to use a third-party SNMP management software... The Oracle SNMP agent will report to a third-party SNMP management software (e.g. Nagios or similar). "*
    My questions are :
    Can you install the Oracle Management Service without the Oracle Enterprise Manager? ...if not then :
    Can you run the Oracle Enterprise Manager with Oracle Standard Edition?
    I will search more on google for answers for these questions...and if I find them i'll post them here...Or maybe someone if faster and knows the answers..so he will post them :)

  • Oracle Monitoring using SNMP

    Is anyone out there using this SNMP as Oracle explains in document
    http://technet.oracle.com/products/oem/management_partners/snmp_wp.html
    Where would i get this software...
    How would I use this with OEM9i

    Well from Oracle document of course,
    Configuring SNMP for Oracle
    http://download.oracle.com/docs/cd/B19306_01/em.102/b16244/chap2.htm#SNMPR002
    What's the Oracle version? btw

  • How do i add Linux systems to be monitored using Virtual agent/SNMP in OLT?

    Dear All,
    I need to know the process to add Linux systems to be monitored using Virtual agent and SNMP in OLT ?
    I have added my details to Virtual agent and chosen ssh and all i get is cannot connect
    Appreciate if someone can give me the detailed screenshot by screenshot process.
    Regards
    Praveen

    On 05/13/2010 09:30 AM, Raja Vengala wrote:
    >
    Yes, the problem is with the old packaged PLINK.exe. Downloaded version is working smoothly. Any reason for shipping the old version ??
    From: Mikael Fries
    Sent: Wednesday, May 12, 2010 11:56 PM
    To: Praveen Arora; Drupad Panchal; Matthew Demeusy; Ashish Dave; Raja Vengala
    Subject: RE: OLT Linux system moniting issue
    Praveen
    I have set up LINUX and virtual agent configs a couple of times, and it has worked pretty ok.
    What I found was that you might have to download a newer version of PLINK.exe and put that onto your OLT system.
    (with the packaged version, I also had some communication issues)
    Try to download the lates plink.exe and see if that works…
    (you may want to restart you system after replacing plink.exe)

  • Using SNMP to monitor Nexus 7000 Series Supervisor Module

    Hello,
    I got a Nexus 7000 supervisor module recently, I met a SNMP problem for this module
    I would like to know which specific OIDs to use to monitor the following using SNMP on a Nexus 7000 supervisor module:
    - Port status
    - CPU total utilization
    - Power Supply status
    - Chassis Fan status
    etc.
    The Nexus is quite different from other Cisco devices - any help will be appreciated!

    hope help,  and 
    port status OID is ifOperStatus
    CPU total utilization OID is 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1
    [root@NET-MONITOR-1 ~]# 
    [root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 ifDescr.83886080
    .1.3.6.1.2.1.2.2.1.2.83886080 = STRING: mgmt0
    [root@NET-MONITOR-1 ~]# 
    [root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 ifOperStatus.83886080
    .1.3.6.1.2.1.2.2.1.8.83886080 = INTEGER: up(1)
    [root@NET-MONITOR-1 ~]# 
    [root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1
    .1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 = Gauge32: 21
    [root@NET-MONITOR-1 ~]#

  • Use SNMP to monitor the power supply status of stacked switches

    Does anybody know how to use SNMP to monitor the status of the internal power supplies of a group of stacked Cisco 3750 switches?
    The switch stack has three 3750-48PS-E switches inter-connected by Cisco StackWise cable. IOS ver 12.1(19)EAlc. A single IP address is used to identify the switch stack. Every time I poll the OID chassisPs1Status (1.3.6.1.4.1.9.5.1.2.4.0 in CISCO-STACK-MIB), I only got the status for the Master switch of the switch stack. Is there any way to poll the power supply status of other switches in the switch stack?
    Thanks a lot!

    Sorry to refresh such an old topic - but I am stuck with exactly this: Monitoring power supplies of a stacked Cisco Catalyst 3750-E.
    I'm using the exact same OID's as described, but the problem is, the information shown on the SNMP output is not correct.
    This morning, a power supply of the first switch failed and switched to RPS. Here the information I got on SNMP:
    snmpwalk -v 2c -c public 192.168.1.50 1.3.6.1.4.1.9.9.13.1
    SNMPv2-SMI::enterprises.9.9.13.1.1.0 = INTEGER: 13
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.2.1006 = STRING: "SW#1, Sensor#1, GREEN "
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.2.2006 = STRING: "SW#2, Sensor#1, GREEN "
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1006 = Gauge32: 41
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.2006 = Gauge32: 40
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.4.1006 = INTEGER: 59
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.4.2006 = INTEGER: 59
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.5.1006 = INTEGER: 0
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.5.2006 = INTEGER: 0
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.6.1006 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.6.2006 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.2.1060 = STRING: "Switch#1, Fan#1"
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.2.2059 = STRING: "Switch#2, Fan#1"
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.3.1060 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.3.2059 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.1059 = STRING: "Sw1, PS1 Normal, RPS NotExist"
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.2060 = STRING: "Sw2, PS1 Normal, RPS NotExist"
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.3.1059 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.3.2060 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.4.1059 = INTEGER: 2
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.4.2060 = INTEGER: 2
    As you see, both PS1 (for both switches) are appearing normal. It doesn't even recognize RPS:
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.1059 = STRING: "Sw1, PS1 Normal, RPS NotExist"
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.2060 = STRING: "Sw2, PS1 Normal, RPS NotExist"
    The first switch's power supply died and now the cable is disconnected. LED's of the power supply are out. And still: The switch happily announces by SNMP it's power supplies are up.
    Is this a known bug? If yes, has it been fixed?
    Model  WS-C3750E-48TD
    Firmware 12.2(37)SE1
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin:0cm;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;
    mso-bidi-font-family:"Times New Roman";
    mso-bidi-theme-font:minor-bidi;}

  • Monitor Ciscoworks using SNMP

    Hi All,
    I would like to monitor Ciscoworks using SNMP. If there are any documents with regards to this configuration, would appreciate if you can share your inputs. Thanks!
    Regards,
    Manoj

    You can send SNMP traps to many management solutions. Sun would probably recommend Sun Management Center.
    http://www.sun.com/software/products/sunmanagementcenter/
    HTH

  • Monitor BGP sessions on VRFs with XR 4.2 using SNMP

    Hello,
    I have an ASR 9006 running IOS XR 4.2 and I want to monitor some BGP sessions under VRFs using SNMP. However, when I poll the device using the OID 1.3.6.1.2.1.15.3.1.2 I only get the BGP sessions on the global VRF. I have read that I have to create 'SNMP contexts' in order to poll information about VRFs but I am not sure how to create them on XR 4.2. Do you know how to do it?
    Thanks in advance.
    David

    Hello,
    thanks to the collaboration of the engineers of Dimension Data I have managed to get it working. In case you are interested in the solution. This would be the configuration on the ASR:
    ; We create the snmp context
    snmp-server context test-ctxt
    ; We associate the context with the VRF
    snmp-server vrf vrfTest
    context test-ctxt
    ; We create the community
    snmp-server community test-com RO 1500
    ; We map the community with the context
    snmp-server community-map test-com context test-ctxt
    Now, when we poll the community associated with the context the peering sessions for that context are returned:
    $ snmpwalk -v2c -c test-com 192.168.0.1 1.3.6.1.4.1.9.9.187.1.2.5.1.3
    SNMPv2-SMI::enterprises.9.9.187.1.2.5.1.3.1.4.10.10.0.1 = INTEGER: 1
    On the ASR:
    #show bgp vrf vrfTest sum | b Neigh
    Wed Jun  5 08:05:26.286 UTC
    Neighbor        Spk    AS MsgRcvd MsgSent   TblVer  InQ OutQ  Up/Down  St/PfxRcd
    10.10.0.1         1 65001       0       0        0    0    0 00:00:00 Idle
    Regards

  • Open Text Content Server Monitoring Agent 5.0 with SCOM using SNMP

     Hi All
    Got a requirement to integrate Opentext monitoring agent with SCOM 2012.
    Can we use SNMP to forward the alerts to SCOM console ? or can we directly monitor opentext content server with some MP's ?
    Regards
    Madhavi.

    That's the point. You cannot discover Windows Computers as Network Devices with SCOM 2012. So sending traps (directly) to SCOM is not possible.
    You can think about a workaround like writing the events to the Windows Event Log and grab them with an Event Log Rule/Monitor. Or send the traps to System Center Orchestrator and write an Alert using the SCOM Integration Pack.
    Cheers,
    Patrick
    Please remember to click “Mark as Answer” on the post that helped you.
    Patrick Seidl (System Center and Private Cloud)
    Website: http://www.syliance.com
    Blog: http://www.systemcenterrocks.com

  • Check alarm status using SNMP

    Hi,
    Is there a way to check if there is an active alarm on a cisco switch/router (M4900/4948 series and 2960 series) using SNMP ?
    I'm looking for a simple quick way to verify if an alarm is active (any alarm)
    is there some sort of general OID that gives me a '1' or '0' ?
    thanks !
    grtz
    Thijs

    Like a table that hold all alarms. No  there is no such thing.
    There are so many reasons there could be an alarm. Hardware state, error rates, utilisation, etc
    There are hardware state OID's that can give you a hardware component status.
    Usually you will find that you have an OID for a component, like a fan.
    1.3.6.1.4.1.9.9.13.1.4.1.3
    You can then walk this OID to find the instances of that OID.
    E.g, a fan for the device and another fan for the power supply, or a fan for each stack member.
    When you know these instances lets say the walk return .1001and .2004 you can query
    1.3.6.1.4.1.9.9.13.1.4.1.3.1001 and 1.3.6.1.4.1.9.9.13.1.4.1.3.2004.
    The values returned can be:
    Specific Object Information
    Object
    ciscoEnvMonFanState
    OID
    1.3.6.1.4.1.9.9.13.1.4.1.3
    Type
    CiscoEnvMonState
    1:normal
    2:warning
    3:critical
    4:shutdown
    5:notPresent
    6:notFunctioning
    Permission
    read-only
    Status
    current
    MIB
    CISCO-ENVMON-MIB ;   -   View Supporting Images
    Description
    The current state of the fan being instrumented.
    So then you have an alarm for the fan's.
    It is similar for other components like a power supply or temperature sensors, etc.
    http://tools.cisco.com/Support/SNMP/do/BrowseMIB.do?local=en&step=2&mibName=CISCO-ENVMON-MIB
    And then there are operational alarms not related to hardware.
    For this you need to monitor values like CPU utilization and define a threshold.
    Good luck,
    Michel

  • Resolution options for Pavilion IPS 23bw monitor

    Will this monitor only operation in 1920 x 1080? Apparently my video card (Radeon 4350) does not support this resolution.
    I did install new card drivers, but still no option for this. Is there any way to use in another resolution, or do I need to upgrade video card?

    Here are the specs for your HP Pavilion 23bw 23-inch IPS LED Monitor and here is the User Guide for this model. Based on this information, this model supports a recommended and maximum resolution of 1920 x 1080 @ 60 Hz. According to the user guide, this model should also support the use of the following resolutions;
    640 x 480 @ 59.94
    720 x 400 @ 70.087
    800 × 600 @ 60.317
    1024 × 768 @ 60
    1280 × 720 @ 60
    1280 × 1024 @ 60.02
    1440 × 900 @ 59.887
    1600 × 900 @ 60
    1680 × 1050 @ 59.954
    1920 × 1080 @ 60
    You may also need to install the HP Pavilion 23bw IPS LED Backlit Monitor Driver to achieve full compatibility and it is possible that the AMD/ATI Radeon HD 4350 won't fully support this monitor.
    Please send KUDOS
    Frank
    {------------ Please click the "White Kudos" Thumbs Up to say THANKS for helping.
    Please click the "Accept As Solution" on my post, if my assistance has solved your issue. ------------V
    This is a user supported forum. I am a volunteer and I don't work for HP.
    HP 15t-j100 (on loan from HP)
    HP 13 Split x2 (on loan from HP)
    HP Slate8 Pro (on loan from HP)
    HP a1632x - Windows 7, 4GB RAM, AMD Radeon HD 6450
    HP p6130y - Windows 7, 8GB RAM, AMD Radeon HD 6450
    HP p6320y - Windows 7, 8GB RAM, NVIDIA GT 240
    HP p7-1026 - Windows 7, 6GB RAM, AMD Radeon HD 6450
    HP p6787c - Windows 7, 8GB RAM, NVIDIA GT 240

  • Programing in java using snmp

    hi
    i am new to snmp so plz bear with me actually i am trying to build a network monitoring system using snmp.how do i go abt it.how do i start?my application will be running on the server and i have made a database in sql which i hav connected using jdbc and now i want to retrieve data from the managed computers i want the object ids of the managed computers and i want to use snmp commands like get() but i am unable to do so as i dont know the required packages which i need to import i would appreciate if someone can provide with some code snippets or any other related information
    thanks

    STOP CROSS POSTING THIS QUESTION
    http://forum.java.sun.com/thread.jspa?threadID=703014

  • How to use SNMP Agent

    Hi All,
    Can anybody tell me how to use SNMP Agent to monitor the Access and Identity Servers

    Hi Ramesh,
    I cannot comment on WebLogic & SNMP - this kind of questions would
    probably need to be asked on a WebLogic forum.
    If you're looking for an SNMP Manager API though, you may want to have a
    look at the Java Dynamic Management Kit (commercial product,
    free evaluation):
    http://java.sun.com/products/jdmk/index.jsp
    Hope this helps,
    -- daniel
    JMX, SNMP, Java, etc...
    http://blogs.sun.com/jmxetc
    null

  • CSM - Load balance using Server CPU

    Hi
    I have a customer who requires the load-balancing prediction
    algorithm to be based on the CPU level of the Server. So the server with the least CPU is chosen at the laod-balancing stage.
    Is there a way to do this?
    Thanks James

    Hi James
    With CSM the only option is DFP (Dynamic feed back protocol). If your application vendor provides DFP agents (which is very unlikely) for the application then these agents can be installed on App servers for the desired purpose.
    Config details at
    http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/csm/4.2.x/configuration/guide/rsfarms.html#wp1039774')">http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/csm/4.2.x/configuration/guide/rsfarms.html#wp1039774
    With ACE you can use SNMP based probes to achieve what you are looking for.
    Syed Iftekhar Ahmed

  • Using SNMP without Agent

    Hi,
    Is there any monitoring SUN software using SNMP without installing agents on the servers ??
    Regards
    Ehab

    Hi Ehab
    MISEHAB wrote:
    Hi,
    Is there any monitoring SUN software using SNMP without installing agents on the servers ?? Solaris does ship with a SNMP Agent out-of-the-box... but it only monitors a limited number of things by default. Or, if you have M-series hardware their XSCF's come with SunMC preinstalled as well: you don't have to install it yourself (and SunMC uses SNMP).
    If you mean monitor Sun software like web or directory servers... some of the older versions of those packages did include SNMP support... but modern versions are moving to other protocols like JMX.
    In general, the best monitoring comes from installing some sort of local Agent, either SunMC, Ops Center, or one of the many tools from Oracle partners (like Halcyon, who I work for)
    Regards,
    [email protected]

Maybe you are looking for

  • Events in iCal doubled after use of iSync and Nokia 6300

    Hi, I've got a problem with the sync though iSync of the Nokia 6300 and iCal on my Mac – a problem which might be related to the imported phoneplugin – but I really don't think so, as other users doesn't seem to have any problems with this phoneplugi

  • How do I share my Pictures and Music Files between Users?

    Hi all, Basically my question is exactly that. I am a new to mac user, and have got a new mac air. Whilst in the store setting up our new mac the people in the shop told us that we could only have 1 icloud account per user, and therefore my wife and

  • Turning off the structure errors in JDeveloper 10.1.3.2

    Is there a way to turn off the structure errors in for .jsp pages in JDeveloper 10.1.3.2. Many of the pages show "Element blah not expected" or "attribute missing" The app I'm working on has lots of old code from a range of developers and I really do

  • SD card in SDXC port

    The information booklet, "Everything Mac", says that the SDXC port takes SD cards, but the computer doesn't recognize that anything is plugged in. Am I missing something?

  • Using SubQuery in Conditions Tab

    Hi, We created a report on test_v and this report is having some additional condition like test_v.ACTION_SEQUENCE = (SELECT MAX(e.action_Sequence) FROM a.x_balance e WHERE e.effective_date <= :As of Date AND e.tax_unit_id = a.test_v.TAX_UNIT_ID AND e