Is it possible to call a subscreen/modal dialog box from the global class
Hi,
Is it possible to call a subscreen or modal dialog box from the global class ..
or is there any option to display a pop screen or subscreen in order to get the values from user which as to be implemented
in the global class..
thanks and regards,
Poornima.
Hi Poornima,
you should follow Uwe's suggestion. The only alternative I can imagine is dynamic document in a dialog container. But I don't know any standardized classes to make use with minimum effort. Have a look at report DD_ADD_FORM_INPUT. Here they put the input field in a container control in a screen; you can put the container control on a dialog container (CL_GUI_DIALOGBOX_CONTAINER).
We will not get rid of any screen for the time being, but if your application is started from any screen, the DIALOGBOX_CONTAINER can start from there.
Regards,
Clemens
Similar Messages
-
How to create non-modal dialog box?
I'm trying to create a non-modal dialog box. The purpose is to show an alarm for the user but should leave the calling VI continuing to run. I have created such a thing -- the problem is that I can't figure out how to get the dialog box to go away! It stops running but the window just hangs around. See the attached VIs and image.
Thanks in advance for your help,
Chad
Attachments:
alarm_ui.png 11 KB
alarm_ui-2.vi 11 KB
message_to_user.vi 11 KBOk, I've attached the files. Thanks for looking at this.
Chad
Attachments:
alarm_ui-2.vi 11 KB
message_to_user.vi 11 KB -
Calling Selection Screen in Modal dialog box
Hi Experts.
I have created screen 9000 having user interface and in tool bar there is create button in the screen 9000
The create button 9001 will call another screen with different I/O fields (9001 is Modal dialog screen).
In the 9001 there is push button for which the selection screen is called 9002.
I have declared 9002 as subscreen and called the screen 9002 in user command.
In the Screen 9001 when user clicks the push button i need to get pop up screen where the user select some data.
How i need to do ?
I am getting error can't call subscreen in modal dialog box.
Thanks,
ERPSAPHI,
HOpe this will help you
How to call table control in subscreen in module pool program
http://sap.ittoolbox.com/groups/technical-functional/sap-dev/reg-tab-strip-control-module-pool-abap-444944
http://12go.com/sap/search?query=title%3A(calling%20subscreens%20in%20module%20pool)
Regards,
Pravin -
How to call jquery function when i close modal dialog box ?
Hello,
I need to call one jquery function when I click on close button of modal dialog box.Can anyone please let me know how can I implement it ?
Thanks,
Dipti ChhatrapatiHi Dipti,
If my understanding is correct, you are using SP Modal Dialog and want to track the close event of this dialog. Then you may use
dialogReturnValueCallback parameter of Options variable. Follow is the code sample:
function ShowModal() {
ExecuteOrDelayUntilScriptLoaded(function () {
var options = {
url: 'page1.aspx',
tite: 'Add Title',
width: 800,
height: 450,
allowMaximize: true,
showClose: true,
dialogReturnValueCallback: scallback
SP.UI.ModalDialog.showModalDialog(options);
}, 'sp.js');
function scallback(dialogResult, returnValue) {
if (dialogResult == SP.UI.DialogResult.OK) {
// call your Jquery method here...
Thanks, Ram -
How to remove the default icons from the toolbar of modal dialog box screen
Hello Friends,
Iam calling a screen from function module using CALL SCREEN statement.
The screen is of type Modal Dialog Box. I created some input fields and buttons in the screen. When the screen is displayed, I can see the tool bar at the bottom along with the input fields and buttons in the screen.
These icons are Continue(Enter), Check, Cancel. How can I supress this??
I mean in my screeen I want only my input fields and buttons but not the default toolbar. How to do that?
Regards,
RajuHi Raju,
Try this...
First try to capture the F-codes of ur button apppearing on the dialog box and then exclude it from the PF-status by passing it to itab.
types: begin of tab_type,
fcode like rsmpe-func,
end of tab_type.
data: tab type standard table of tab_type with
non-unique default key initial size 10,
wa_tab type tab_type.
clear tab.
move 'DELE' to wa_tab-fcode.
append wa_tab to tab.
move 'PRIN' to wa_tab-fcode.
append wa_tab to tab.
set pf-status 'STA3' excluding tab.
Cheers,
Simha.
Reward all the helpful answers.. -
Hi,
I have an ALV on suppose screen 3000, I have created a button in the tool bar to call another ALV, but my question is, can we display ALV in modal dialog box screen(because the requirement is to display ALV as a popup)
So when i changed the screen type to normal screen, my alv is coming,,but when i change the screen type to modal dialog box, then no ALV is being displayed in the output. Only blank screen is displayed.
Can you please help me.
Thanks.Hello
The problem is that you have to take into account that the ALV in the popup (or modal dialogbox) is displayed on a different screen level:
level 0 = main screen
level 1 = 1st popup
level 2 = 2nd popup
We have up to 9 screen level available.
The following sample report ZUS_SDN_ALV_IN_POPUP is a variant of my sample report ZUS_SDN_TWO_ALV_GRIDS.
Depending on whether you mark P_POPUP or not the second ALV grid is additionally displayed on a popup.
*& Report ZUS_SDN_ALV_IN_POPUP
*& Thread: ALV in modal dialog box
*& https:||<a class="jive_macro jive_macro_thread" href="" __jive_macro_name="thread" modifiedtitle="true" __default_attr="762642"></a>
*& Screen '0100' contains no elements.
*& ok_code -> assigned to GD_OKCODE
*& Flow logic:
* PROCESS BEFORE OUTPUT.
* MODULE STATUS_0100.
* PROCESS AFTER INPUT.
* MODULE USER_COMMAND_0100.
REPORT zus_sdn_alv_in_popup.
TYPE-POOLS: abap.
DATA:
gd_okcode TYPE ui_func,
gd_repid TYPE syst-repid,
" containers and ALV grids for main screen
go_docking TYPE REF TO cl_gui_docking_container,
go_splitter TYPE REF TO cl_gui_splitter_container,
go_cell_top TYPE REF TO cl_gui_container,
go_cell_bottom TYPE REF TO cl_gui_container,
go_grid1 TYPE REF TO cl_gui_alv_grid,
go_grid2 TYPE REF TO cl_gui_alv_grid,
" container and ALV grid for popup
go_docking3 TYPE REF TO cl_gui_docking_container,
go_grid3 TYPE REF TO cl_gui_alv_grid,
gs_layout TYPE lvc_s_layo.
DATA:
gt_knb1 TYPE STANDARD TABLE OF knb1,
gt_knvv TYPE STANDARD TABLE OF knvv.
PARAMETERS:
p_popup AS CHECKBOX DEFAULT ' '.
* CLASS lcl_eventhandler DEFINITION
CLASS lcl_eventhandler DEFINITION.
PUBLIC SECTION.
CLASS-METHODS:
handle_double_click FOR EVENT double_click OF cl_gui_alv_grid
IMPORTING
e_row
e_column
es_row_no
sender.
ENDCLASS. "lcl_eventhandler DEFINITION
* CLASS lcl_eventhandler IMPLEMENTATION
CLASS lcl_eventhandler IMPLEMENTATION.
METHOD handle_double_click.
* define local data
DATA:
ls_knb1 TYPE knb1.
CHECK ( sender = go_grid1 ).
READ TABLE gt_knb1 INTO ls_knb1 INDEX e_row-index.
CHECK ( ls_knb1-kunnr IS NOT INITIAL ).
IF ( p_popup = abap_true ).
CALL METHOD cl_gui_cfw=>set_new_ok_code
EXPORTING
new_code = 'POPUP'
* IMPORTING
* rc =
ELSE.
* Triggers PAI of the dynpro with the specified ok-code
* * CALL METHOD cl_gui_cfw=>set_new_ok_code( 'DETAIL' ). " not on 4.6c
CALL METHOD cl_gui_cfw=>set_new_ok_code
EXPORTING
new_code = 'DETAIL'
* IMPORTING
* rc =
ENDIF.
ENDMETHOD. "handle_double_click
ENDCLASS. "lcl_eventhandler IMPLEMENTATION
START-OF-SELECTION.
" Select data
SELECT * FROM knb1 INTO TABLE gt_knb1
WHERE bukrs = '1000'.
PERFORM init_controls.
* Display data
gs_layout-grid_title = 'Customers'.
CALL METHOD go_grid1->set_table_for_first_display
EXPORTING
i_structure_name = 'KNB1'
is_layout = gs_layout
CHANGING
it_outtab = gt_knb1
EXCEPTIONS
OTHERS = 4.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
gs_layout-grid_title = 'Customers Details (Sales Areas)'.
CALL METHOD go_grid2->set_table_for_first_display
EXPORTING
i_structure_name = 'KNVV'
is_layout = gs_layout
CHANGING
it_outtab = gt_knvv " empty !!!
EXCEPTIONS
OTHERS = 4.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
gs_layout-grid_title = 'Customers Details (Sales Areas)'.
CALL METHOD go_grid3->set_table_for_first_display
EXPORTING
i_structure_name = 'KNVV'
is_layout = gs_layout
CHANGING
it_outtab = gt_knvv " empty !!!
EXCEPTIONS
OTHERS = 4.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
* Link the docking container to the target dynpro
gd_repid = syst-repid.
CALL METHOD go_docking->link
EXPORTING
repid = gd_repid
dynnr = '0100'
* CONTAINER =
EXCEPTIONS
OTHERS = 4.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
* Link the docking container to the popup
gd_repid = syst-repid.
CALL METHOD go_docking3->link
EXPORTING
repid = gd_repid
dynnr = '0200'
* CONTAINER =
EXCEPTIONS
OTHERS = 4.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
* NOTE: dynpro does not contain any elements
CALL SCREEN '0100'.
* Flow logic of dynpro (does not contain any dynpro elements):
*PROCESS BEFORE OUTPUT.
* MODULE STATUS_0100.
*PROCESS AFTER INPUT.
* MODULE USER_COMMAND_0100.
END-OF-SELECTION.
*& Form INIT_CONTROLS
* text
* --> p1 text
* <-- p2 text
FORM init_controls .
* Create docking container
CREATE OBJECT go_docking
EXPORTING
parent = cl_gui_container=>screen0 " main screen -> level 0 !!!
ratio = 90
EXCEPTIONS
OTHERS = 6.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
* Create splitter container
CREATE OBJECT go_splitter
EXPORTING
parent = go_docking
rows = 2
columns = 1
* NO_AUTODEF_PROGID_DYNNR =
* NAME =
EXCEPTIONS
cntl_error = 1
cntl_system_error = 2
OTHERS = 3.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
* Get cell container
CALL METHOD go_splitter->get_container
EXPORTING
row = 1
column = 1
RECEIVING
container = go_cell_top.
CALL METHOD go_splitter->get_container
EXPORTING
row = 2
column = 1
RECEIVING
container = go_cell_bottom.
* Create ALV grids
CREATE OBJECT go_grid1
EXPORTING
i_parent = go_cell_top
EXCEPTIONS
OTHERS = 5.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
* Set event handler
SET HANDLER: lcl_eventhandler=>handle_double_click FOR go_grid1.
CREATE OBJECT go_grid2
EXPORTING
i_parent = go_cell_bottom
EXCEPTIONS
OTHERS = 5.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
" Create container and grid for popup.
* Create docking container
CREATE OBJECT go_docking3
EXPORTING
parent = cl_gui_container=>screen1 " !!! popup !!!
ratio = 90
EXCEPTIONS
OTHERS = 6.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
" NOTE: Starting from a main dynpro (screen level 0) the first popup
" (or modal dialogbox) is on level 1 !!!
" Using cl_gui_container=>screen0 fails to display ALV grid.
CREATE OBJECT go_grid3
EXPORTING
i_parent = go_docking3
EXCEPTIONS
OTHERS = 5.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
ENDFORM. " INIT_CONTROLS
*& Module STATUS_0100 OUTPUT
* text
MODULE status_0100 OUTPUT.
SET PF-STATUS 'STATUS_0100'. " contains push button "DETAIL"
* SET TITLEBAR 'xxx'.
* Refresh display of detail ALV list
CALL METHOD go_grid2->refresh_table_display
* EXPORTING
* IS_STABLE =
* I_SOFT_REFRESH =
EXCEPTIONS
OTHERS = 2.
IF sy-subrc <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
* WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
ENDMODULE. " STATUS_0100 OUTPUT
*& Module USER_COMMAND_0100 INPUT
* text
MODULE user_command_0100 INPUT.
CASE syst-dynnr.
WHEN '0100'.
CASE gd_okcode.
WHEN 'BACK' OR
'END' OR
'CANC'.
SET SCREEN 0. LEAVE SCREEN.
* User has pushed button "Display Details"
WHEN 'DETAIL'.
PERFORM entry_show_details.
WHEN 'POPUP'.
PERFORM entry_show_details.
go_grid3->refresh_table_display( ). " required
CALL SCREEN '0200' STARTING AT 5 5
ENDING AT 150 30.
WHEN OTHERS.
ENDCASE.
WHEN '0200'.
set screen 100. leave screen.
ENDCASE.
CLEAR: gd_okcode.
ENDMODULE. " USER_COMMAND_0100 INPUT
*& Form ENTRY_SHOW_DETAILS
* text
* --> p1 text
* <-- p2 text
FORM entry_show_details .
* define local data
DATA:
ld_row TYPE i,
ls_knb1 TYPE knb1.
CALL METHOD go_grid1->get_current_cell
IMPORTING
e_row = ld_row.
READ TABLE gt_knb1 INTO ls_knb1 INDEX ld_row.
CHECK ( syst-subrc = 0 ).
SELECT * FROM knvv INTO TABLE gt_knvv
WHERE kunnr = ls_knb1-kunnr.
ENDFORM. " ENTRY_SHOW_DETAILS
Regards
Uwe -
Standard 'X' in a modal dialog box not working
Hi,
I have created a module pool and calling screen from main screen using Call screen.... Starting... ending... statement.
It is a modal dialog box screen. As a standard a [X] appears on top right corner. But when I click it doesn't work. it does not even fire PBO. How can I make it work?Hi,
Set next screen as 0, not the screen itself. Then you are able to close it this way.
Regards
Marcin
I was wrong, this will only close the modal box each time after the dialog step is completed. To activate this magic 'X' (allow closing the window with ALT+F4) in PBO set status (type dialog box ) and activate CANCEL and CONTINUE buttons. Now when you try closing the window either by CANCEL button or using X, sy-ucomm (ok_code of the screen) will store CANCEL function code. This way you can simply say LEAVE SCREEN . That works fine, I checked.
Regards
Marcin
Edited by: Marcin Pciak on Mar 17, 2009 11:16 PM -
Screen sequence processing when using modal dialog box
I have been struggling with a dialog program which I have written. I have a screen which has 2 radiobuttons and a check box (screen 100). If the checkbox is marked, a modal dialog screen pops up (screen 150). If I complete both input fields on screen 150, I can go through to screen 200, then back out of screen 200 to screen 100, and then I can back out 100 to screen 0.
The problem I have is the validation I have put in screen 150 if one or both input fields have no values or if I want to exit screen 150. If I exit screen 150, in order to get back to screen 100 in the main screen I need to do CALL SCREEN 100 as if I use SET SCREEN 100, 100 then appears in my modal dialog box screen.
If I try to back out of screen 100 to screen 0, the program then brings up screen 150 in the PAI part of the module and then go to screen 0 when I close screen 150 even though I have coded SET SCREEN 0. LEAVE SCREEN. in the user command module of screen 100. Here is my code:
<u><b>screen 100</b></u>
PROCESS BEFORE OUTPUT.
MODULE status_0100.
PROCESS AFTER INPUT.
MODULE user_command_0100.
<b>
<u>Modules for 100</u></b>
*& Module STATUS_0100 OUTPUT
* text
MODULE status_0100 OUTPUT.
SET PF-STATUS 'ZL_PWB_GR1'.
SET TITLEBAR 'ZL_PWB_GR1'.
CLEAR: w_hse_stock, w_new_product, wa_sto, w_reverse,
mara-matnr, mkpf-mblnr.
PERFORM release_lock.
REFRESH CONTROL 'TC_GR' FROM SCREEN 0200.
ENDMODULE. " STATUS_0100 OUTPUT
*& Module USER_COMMAND_0100 INPUT
* text
MODULE user_command_0100 INPUT .
CASE ok_code.
WHEN 'ENTER'.
IF w_reverse = space.
CALL SCREEN 0200.
ELSE.
CALL SCREEN 0150 STARTING AT 30 2
ENDING AT 75 5.
ENDIF.
WHEN 'BACK' OR 'EXIT' OR 'CANC'.
w_pai = c_yes.
SET SCREEN 0.
LEAVE SCREEN.
ENDCASE.
ENDMODULE. " USER_COMMAND_0100 INPUT
<u><b>screen 150</b></u>
PROCESS BEFORE OUTPUT.
MODULE status_0150.
PROCESS AFTER INPUT.
MODULE exit_command_0150 AT EXIT-COMMAND.
FIELD mara-matnr MODULE check_matnr.
FIELD mkpf-mblnr MODULE check_art_doc.
<u><b>Modules for 150</b></u>
MODULE user_command_0150.
*& Module STATUS_0150 OUTPUT
* text
MODULE status_0150 OUTPUT.
SET PF-STATUS 'GR_REV'.
SET TITLEBAR 'GR_REV'.
ENDMODULE. " STATUS_0150 OUTPUT
*& Module exit_COMMAND_0150 INPUT
* text
MODULE exit_command_0150 INPUT.
IF sy-ucomm = 'EXIT'.
CALL SCREEN 100.
ENDIF.
ENDMODULE. " exit_COMMAND_0150 INPUT
*& Module check_matnr INPUT
* Check if issues has been filled and if issue is a valid article no.
MODULE check_matnr INPUT.
DATA: l_matnr TYPE matnr.
IF mara-matnr IS INITIAL.
MESSAGE i010(ad) WITH 'Issue no. required'.
EXIT.
ELSE.
SELECT SINGLE matnr FROM mara INTO l_matnr
WHERE matnr = mara-matnr.
IF sy-subrc NE 0.
CLEAR l_matnr.
MESSAGE i010(ad) WITH 'Issue does not exist'.
ENDIF.
ENDIF.
ENDMODULE. " check_matnr INPUT
*& Module check_art_doc INPUT
* text
MODULE check_art_doc INPUT.
IF mkpf-mblnr IS INITIAL.
MESSAGE i010(ad) WITH 'Article document no. required'.
EXIT.
ELSE.
PERFORM get_art_doc USING mara-matnr
mkpf-mblnr.
IF sy-subrc NE 0.
MESSAGE i010(ad) WITH 'No article document exists for this issue'.
ENDIF.
ENDIF.
ENDMODULE. " check_art_doc INPUT
*& Module USER_COMMAND_0150 INPUT
* text
MODULE user_command_0150 INPUT.
CASE sy-ucomm.
WHEN 'ENTE'.
IF mara-matnr NE space AND mkpf-mblnr NE space.
CALL SCREEN 200.
ELSE.
* MESSAGE i010(ad) WITH 'Please fill in both fields'.
SET SCREEN 150.
ENDIF.
ENDCASE.
ENDMODULE. " USER_COMMAND_0150 INPUT
Any suggestions or pointers would be greatly appreciated as I am going round in circles.
Thanks
LarissaHave got around this by removing the references to SET SCREEN 150. This way, I can get around the screen sequencing. It just means that I cannot keep my screen 150 in view if a validation message occurs but for now it will do for what I need.
Thank you for your help anyway.
Larissa -
You too can display non-modal dialog boxes: LrDialogs.presentFloatingDialog
Undocumented function: LrDialogs.presentFloatingDialog
ref: http://feedback.photoshop.com/photoshop_family/topics/sdk_lrdialogs_presentfloatingdialog_ and_showstringsdialog_undocumented
This works for displaying non-modal dialog box:
LrFunctionContext.postAsyncTaskWithContext( "test", function( context )
local LrPhotoPictureView = import 'LrPhotoPictureView'
local photo = catalog:getTargetPhoto()
local pictureView = LrPhotoPictureView.makePhotoPictureView{
width = 400, height = 400, photo = photo,
local result = LrDialogs.presentFloatingDialog {
title = "Thumbnail test",
background_color = LrColor ("white"), -- required for (uncolored) static_text display, else inside of box is black and so can't see black text.
contents = vf:column {
vf:static_text {
title = photo:getFormattedMetadata ("fileName"),
pictureView,
--vf:edit_field { - no sirve, presumably keystrokes are not trapped by box.
-- bind_to_object = prefs,
-- value = app:getGlobalPrefBinding( 'tempForTest' ),
vf:push_button {
title = "Click me",
action = function( button )
app:show{ info="Pushed" } -- glorified call to LrDialogs.presentModalDialog - works.
end,
-- LrDialogs( app:getGlobalPref( 'tempForTest' ), result ) -- no sirve.
end )
Enjoy!
Robjarnoh wrote:
there is no way to activate previously opened dialog?
I assume that to be the case, and so it takes a moment to come up if there is much contents.
jarnoh wrote:
Doesn't seem to be really useful
For me, it would be very useful, if it was reliable, but so far, not so good.
UPDATE: Bug I thought was in non-modal dialog is also in modal dialog (scrolled_view must not be followed by another components in tabbed container - see comments in code below):
LrFunctionContext.postAsyncTaskWithContext( "tt", function( context )
local props = LrBinding.makePropertyTable( context )
props.tv = 0
local vi = {
vf:tab_view {
vf:tab_view_item {
identifier = "t1",
title = "T1",
vf:static_text {
title = "temp1"
vf:tab_view_item {
identifier = "t2",
title = "T2",
vf:scrolled_view {
vf:slider {
bind_to_object = props,
value = LrView.bind( 'tv' ),
-- with this here, Lr crashes after adjusting slider and then switching tabs - comment it out, and all is well:
--vf:static_text {
-- title = "this cant be here",
LrDialogs.presentModalDialog {
title = "test",
contents = vf:view( vi )
end )
R
Message was edited by: Rob Cole -
If is possible to add new local var to sequence from the outside?
If is possible to add new local var to sequence from the outside?
I mean insert a new local variable to Sequence.Locals list or via expression, or by LabView VI (Sequence Context). or any another way.
Thanks.Hi,
The simplest way would be to use the API TS method PropertyObject.SetValBoolean, PropertyObject.SetValNumber or PropertyObject.Set ValString. With the SequenceContext you create a PropertyObject using the method SequenceContext.AsPropertyObject, which you use as the reference for the the SetVal method.
For the SetVal method, pass the full lookup string of your variable eg "Locals.MyString" and set the option parameter to 0x01 (insert if missing).
If you are calling this from LabVIEW, then use the SetVal property VI.
This will insert a varable into the Locals that is "in scope" of the step that is performing the task.
In the TestStand Help - "Using the API in Different Programming Languages" and in the TestStand User manuals there is more information to help you.
This will only make a runtime version of your Local. ie when your sequencefile stop executing your Local will not exist in the Static version of the Sequence File.
Hope this helps
Ray Farmer
Regards
Ray Farmer -
Can't access Modal dialog box via Powershell script
Hi,
I have a powershell script to login to an IE website and everything works fine excepting when I call a modal dialog box. I've attached the line where the modula dialog is invoked. When it gets to this part the script hangs and I'm unable
to get past this. I've googled a few articles where it suggests I should run an a scheduled task to scrape for the modal dialog box but I've tried it without much luck. If you can please give me some pointers on resolving this issue.
Thnx
Sue.
$ie.Document.getElementsByTagName("button") | ? { $_.innerText -eq 'UNLOCK User' } | Select-Object -first 1 | % { $_.Click() }
SueHi,
I have a powershell script to login to an IE website and everything works fine excepting when I call a modal dialog box. I've attached the line where the modula dialog is invoked. When it gets to this part the script hangs and I'm unable
to get past this. I've googled a few articles where it suggests I should run an a scheduled task to scrape for the modal dialog box but I've tried it without much luck. If you can please give me some pointers on resolving this issue.
Thnx
Sue.
$ie.Document.getElementsByTagName("button") | ? { $_.innerText -eq 'UNLOCK User' } | Select-Object -first 1 | % { $_.Click() }
Sue -
Hello,
I've created a function which call a modal dialog box. In this one, the user has to choose a value in a listbox. It's like a popup for the user.
The screen is called like below:
CALL SCREEN 0500 STARTING AT 5 5
ENDING AT 100 10.
The screen is defined with a pf-status containing only one icon(pf-key) with value VALID. In the process after input, I'm controlling the value like below:
MODULE USER_COMMAND_0500 INPUT.
data : save_ok like sy-ucomm.
save_ok = lv_code.
case save_ok.
when 'VALID'.
if lv_prio(2) lt 4.
message s098(ze).
else.
set screen 0.
leave screen.
endif.
when others.
message s098(ze).
endcase.
ENDMODULE. " USER_COMMAND_0500 INPUT
I have a bug when the program is calling twice the function means the popup.
Instance of program Z.
loop at X.
call function YY.......
endloop.
The table X contain two values.
When the popup is called the first time in the loop, all is ok, but when the popup is called the next time, if the user doesn't choose a value in the listbox and just press on the keyboard Enter, then the system go completly out of the program Z and doesn't go in the user_command !!!!
I've defined the field (listbox) as required, but no effect.
Is it a bug of the system ? or do I defined the screen incorrectly or ???
Thanks a lot for your help.Hi merle,
i have u debugged the program ? Is it coming to user-command event ?
What is the type of this field lv_prio ?
comment set screen 0 & use leave to screen 0
if lv_prio(2) lt 4.
message s098(ze).
else.
leave to screen 0.
endif. -
How to dispose the modal dialog box
hi all
can any one please tell me how to supress the modal dialog box.
Means iam triggering the a new pop up (modal dialog box) after this
when iam click ok or cancel buttons on this modal dialog box it is not returing to
the screen from where it is tiggering. Can any one tell how to achieve this.
what r the statements i have to write for this in the PAI.HI,
in PAI u have to write like..
CASE OK_CODE.
WHEN 'OK'.
UR CODE.........
WHEN 'CANC'.
SET SCREEN 0.
LEAVE SCREEN.
OR
LEAVE TO SCREEN XXX. " UR CALLING SCREEN NUMBER
ENDCASE.
Pls close the thread if the problem is solved and reward to all helpful answers.
Regards
SAB -
My iphone 4S has problem in making and receiving the calls. While making the call , call fails and netwrok disappears. Like wise no voice is heard for incoming calls. This happened after return from the overseas travel.
Hello SamSax
Check out the assist page below for troubleshooting call connectivity.
Calls and connection issues
http://www.apple.com/support/iphone/assistant/calls/
Thanks for using Apple Support Communities.
Regards,
-Norm G. -
I cannot log onto the App Store, the page appears when I call it from the dock or the Apple menu and I can call the log-in box from the menu bar, but on signing in the spinning icon just keeps spinning,(not the beachball). Using 10.6.7 and up-to-date on all software. Any suggestions?
Could be a third party app preventing you from being able to login.
Mac App Store: Sign in sheet does not appear, or does not accept typed text
If it's not a third party issue, follow the instructions here.
Quit the MAS if it's open.
Open a Finder window. Select your Home folder in the Sidebar on the left then open the Library folder then the Caches folder.
Move the com.apple.appstore and the com.apple.storeagent files from the Caches folder to the Trash
From the same Library folder open the Preferences folder.
Move these files Preferences folder to the Trash: com.apple.appstore.plist and com.apple.storeagent.plist
Same Library folder open the Cookies folder. Move the com.apple.appstore.plist file from the Cookies folder to the Trash.
Relaunch the MAS.
Maybe you are looking for
-
How do you connect macbook to a tv?
How do i connect my macbook to a tv?
-
ARCHIVING OBJECT : CO_TOTAL - Fiscal year issue regarding
Hi, I am trying to archive (01.04.2007 - 31.03.21008). - fiscal year : 2008 when i give the fiscal year : 2008 ( period 1 - 12) it 's archiving all the datas relevant to 01.04.2007 - 31.03.2008. which is correct. but some of company codes foll
-
None of the zoom functions address this problem. It is not that all the text is too large or too small, but that the headings in relation to the text are now too big. This means that if I decrease the zoom level to one that the headings appear normal
-
Can I link a debit card to 2 apple accounts?
IS it possible to do the above?
-
[Eclipse - Axis] Generate Client from wsld, wrong type for unbounded elemen
Hi all! I'm not expert on wsdl format, but in my work activities I have to take wsdl they send to me and generate Java code in Eclipse. One of last wsdl they sent to me contains the following element: <xs:element ref="ns0:CodicePraticaDistributore" m