Is it possible WINDOWS 2012 monitor by SCOM 2007 R2

Hi,
In WIN 2012, i have installed 2007 SCOM agent .
Now agents are showing in healthy in console, we also pull only memory utilization report, but unable to get any alert (like disk, processor, service stop etc).
PS:For testing, i have create a process monitoring and set threshold , then get alert for this process.   
can any one help me about how to monitor win 2012 all parameters.
Many thanks in advance !!!!!
Regards,
Dilip 

Hi,
You can use the MP
System Center Management Pack for Windows Server Operating System
http://www.microsoft.com/en-us/download/details.aspx?id=9296
"Other Requirements: All management packs (MPs) included in this download are supported on System Center Operations Manager 2007 R2 and above."
Here is a blog regarding to monitor server 2012 with SCOM 2012 R2:
Monitor Windows Server 2012 from SCOM 2007R2 with a new MP
http://blogs.technet.com/b/mspfe/archive/2012/09/27/monitor-windows-server-2012-from-scom-2007r2-with-a-new-mp.aspx
Regards,
Yan Li
Regards, Yan Li

Similar Messages

  • Windows Azure Monitoring in SCOM 2012 R2

    Hi,
    We have Azure subscription which has few cloud services and VM in running state. We want to monitor the VMs running on Azure using SCOM 2012 R2 running on our corp network behind firewall. SCOM Server connected to the internet through the corp proxy.
    We have imported the Azure Management packs in to SCOM and Added the Subscription successfully. But, the Azure resource inventory like Discovered Cloud Services, Discovered Storage, Discovered Virtual Machines are empty.
    Kindly please help to configure azure monitoring using SCOM 2012 R2.
    Thanks
    Kumaresan Lakshmanan

    Hi 
    SCOM monitoring check data in azure store, check if the events and performace data is transferring to the azure store.if data is not transfering for event id counters monitor fail to work . 
    refer below link for more information
    Implementing Windows Azure
    Diagnostics (http://go.microsoft.com/fwlink/?LinkId=186765).
    Transferring Diagnostic
    Data to Windows Azure Storage (http://go.microsoft.com/fwlink/?LinkId=191347). 
    Regards
    sridhar v

  • Exchange servers not reflecting in Server State tab in monitoring in SCOM 2007 R2

    Hi,
    We have added few exchange servers in SCOM 2007 r2 for monitoring, but few of them are not reflecting in the Monitoring> Exchange 2010> Server State tab, whereas they are healthy in admin tab.
    Can anyone help on this?
    TIA

    Check from following:
    open firewall.
    Enable Exchange Rule for monitoring
    Enable proxy Agents
    Check Configure monitoring Exchange 2010 as exist below link
    http://www.msexchange.org/articles-tutorials/exchange-server-2010/management-administration/monitoring-exchange-2010-opsmgr-2007-r2-part1.html
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • Certificates monitoring using scom 2007 r2

    B John

    Hi,
    PKI Certificate Verification is a custom MP. 
    http://www.systemcentercentral.com/PackCatalog/PackCatalogDetails/tabid/145/IndexID/24860/Default.aspx
    OpsMgr 2007 (SCOM): Coretech Certificates Expire checker Management Pack – 0.0.0.1
    http://blog.coretech.dk/jgs/opsmgr-2007-scom-coretech-certificates-checker-management-pack-0001/
    Monitoring Certificates In SCOM
    http://blogs.technet.com/b/omx/archive/2013/01/30/monitoring-certificates-in-scom.aspx
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.

  • SCOM 2007 R2 vs Windows 8.1 client Management Pack

    Hello
    We are running rollout of replacing XP to Windows 8.1 on clients monitored by SCOM 2007 R2.
    Clients are discovered but we miss a Win8.1 Client Management Pack to discover and monitor basic parameters as we used to do for WinXP clients. 
    As far as I know there is no Win8.1 Client MP released yet but I found a workaround (custom MP) which allows to discover Win8.1 clients when Windows 8 Client MP is imported. (http://blogs.technet.com/b/kevinholman/archive/2014/04/01/windows-8-client-os-mp-doesn-t-discover-windows-8-1.aspx)
    The problem is that Windows 8 Client MP is designed for SCOM 2012. 
    Do you know if it is possible to import the MP above to SCOM 2007 R2 without any consequences?
    What is the recommendation for the way forward? Do you think upgrade to SCOM 2012 is a must?
    Regards,
    Arkadiusz

    Hi Arkadiusz:
    The download page for the Windows 8 client management pack does accurately indicate SCOM 2012 is the platform.
    http://www.microsoft.com/en-us/download/confirmation.aspx?id=38434
    The Windows 8 Client Monitoring and Aggregate management packs will not import into SCOM 2007 R2. You do need to upgrade your management group to SCOM 2012 or SCOM 2012 R2 in order to use the Windows 8 client management pack.
    John Joyner MVP-SC-CDM

  • Update agent from SCoM 2007 to SCOM 2012

    Expets,
    We have SCOM 2007 R2 CU7on 1 server.
    we installed another single SCOM 2012 r2 on another server.
    when i push the agent from the SCOM 2012 to machine still monitored by SCOM 2007, the machine appear in pending management under device management under  setting
    tab
    but when i remove the SCOM 2007 manualy, there is no problem and the installing of SCOM 2012 agent done successfully
    any way to make SCOM 2012 agent automatically without remove SCOM 2007 agent ?
    Ahmad Samir | MCSE 2003 | MCTS: Exchange 2010, MCTS: Lync 2010. MCTS: SCOM 2007

    Hi,
    If SCOM 2012 and SCOM 2007 R2 belong to the same management group, then you are trying to make your agents multi-homing, and if so, just discovery them and push agent to them should work.
    Here is a similar thread, please go through it:
    http://social.technet.microsoft.com/Forums/en-US/c6d15d7f-1779-47ea-a437-bc6ab00e2f64/upgrading-scom-2007-r2-to-scom-2012?forum=operationsmanagergeneral
    And we may need to logon to one agent and check its event viwer for operation manager log for more details.
    Regards,
    Yan Li
    Regards, Yan Li

  • Scom 2007 and scom 2012 agent multi home

    is there version limit for the agent multihom for scom 2007 and scom 2012?
    In technet i found it for SCOM upgrade it mentioned need scom 2007 CU4 and above, how about for multihome approach for SCOM agent?
    Besides that, instead of agent upgrade, could we perform agent uninstallation scom 2007 and reinstall scom 2012?
    Thanks for your advice.

    Hi Cylim,
    You can upgrade your agents to SCOM 2012 only from SCOM 2007 R2 CU4. Please look at these helpful links:
    http://blogs.technet.com/b/kevinholman/archive/2014/01/20/do-i-need-a-specific-cumulative-update-release-ur-in-order-to-upgrade-to-scom-2012-or-2012-sp1-or-2012-r2.aspx
    http://blogs.catapultsystems.com/cfuller/archive/2012/05/31/quicktricks-multi-homing-an-agent-to-opsmgr-2012-scom-sysctr.aspx
    http://blogs.catapultsystems.com/cfuller/archive/2014/04/02/multihomed-migrations-in-operations-manager-lessons-from-the-field.aspx
    As Scott mentioned, you can uninstall SCOM 2007 agent and install SCOM 2012 agent on one or a few servers, and see if they report properly to both management groups SCOM 2007 and SCOM 2012:
    http://dynamicdatacenter.wordpress.com/2012/10/15/om-2012-agent-report-to-scom-2007-not-r2-scom-2012/
    Natalya

  • SCOM 2007 Runbook "Missing Extensions"

    Yes, I have the OM console installed on the Runbook server.
    We are using SCO 2012 R2 with SCOM 2007 R2 CU7. 
    I have a simple runbook which starts with the Monitor Date/Time activity > finds warnings > the age > and either closes the warning or creates a critical alert depending on some variables.  The runbook runs great in the tester. But when we
    actually run it, it will start and then abruptly stop. The log will say that it is missing extensions. 
    Even when i create a 1 activity runbook (Get Alert) it will succeed in the tester and fail with missing extensions when run live. 
    Very similar to: http://social.technet.microsoft.com/Forums/en-US/2f30bc5a-4387-4ff2-a518-2d80cfaa0686/runbook-error-some-of-the-extensions-are-missing.
     Except we have the console installed.
    Question 1: What else may cause the SCOM IP to be missing some extensions/binaries? 
    Question 2: When using SCO 2012 R2 with SCOM 2007 R2, should we have the SCOM 2007 R2 console, or does the IP actually need the SCOM 2012 console?
    Question 3: Why arent these extensions/binaries built into the SCOM IP, or at even installed when SCO is installed? I'm no software developer, but it seems incomplete. (This question was mostly rhetorical)
    - Get on the floor, do that dinosaur

    Hi,
    the problem in the thread you referred to was that the Integration Pack was not Installed on the executing Runbook Server: "Runbook 'Name' stopped some of the Extensions are missing"
    See
    http://www.sc-orchestrator.eu/index.php/scoblog/99-functionality-differences-executing-a-runbook-with-runbook-tester
    The knowledge with the SCOM2012 IP and Operator Console  is a combination from my experience from field and here:
    http://social.technet.microsoft.com/Forums/en-US/8247b6b8-d84b-46f5-a964-2d04568eb5cb/orchestrator-2012-with-ip-for-operations-manager-2007-r2?forum=scoscip
    Regards,
    Stefan
    www.sc-orchestrator.eu ,
    Blog sc-orchestrator.eu

  • SCOM 2012 Monitoring of windows based service

    Hi,
    Here my requiremt is to monitoring windows based service in scom 2012. The agent server is a windows based machine and I need to monitor these service, once they are in stopped state or in starting state. The server state is ahowing healthy.
    Could someone pls guide me or share me the details for configure a wondows based service in scom for monitoring.
    Below is the service i want to monitor through scom 2012
    Thanks
    Regards, Rajeev Parambil

    Hi,
    Please follow the steps below:
    1. Under Authoring console, right click Monitors, then choose create a Monitor, select Unit monitor.
    2. With the Create a Unit Monitor Wizard, we select Basic Service Monitor under Windows Services.
    3. Choose the destinaton management pack to store the monitor. Click Next.
    4. Specify the monitor name, and choose Monitor target class, such as Windows Operation System. Click Next.
    5. Then select Service that you want to monitor, we can specify the computer name, and then find the service under the computer. Click Next.
    6. Configure Health and Configure Alert.
    Regards,
    Yan Li
    Regards, Yan Li

  • Windows client monitoring Management packs for SCOM 2012

     Hello All,
     Please provide the link for  windows client monitor management pack for SCOM 2012 SP1 ,if there is any  available .
    I have got one link for this but it is for SCOM 2007 .
    Regards
    Richa KM

    http://www.microsoft.com/en-us/download/details.aspx?id=15700
    Yes you can download from this link and you can import it in scom 2012 sp1.although it is for scom 2007

  • SharePoint 2010 SP2 hosted on Windows 2012 R2 NOT discovered by SCOM 2012 R2 + 2 SP MP's

    What is the process to get SharePoint 2010 Management Packs loaded in System Center 2012 R2 to discover/monitor SharePoint 2010 SP2 (14.0.7121.5000) loaded on Windows 2012 R2?
    View of installed system:
     System Center 2012 R2 loaded on Windows 2012 R2 (supported separately by SQL 2012 SP1 loaded on Windows 2012 R2)
    -Microsoft SharePoint 2010 Products Management Pack for System Center Operations Manager 2007
    -System Center 2012 Monitoring Pack for SharePoint 2010
     SharePoint 2010 SP2 (14.0.7121.5000) loaded on Windows 2012 R2 (supported separately by SQL 2012 SP1 loaded on Windows 2012 R2)
    The SharePoint 2010 Management Shell works fine!
    Result
    Event 0, Operations Manager - Cannot identify which SharePoint farm server is associated with. Check the management pack guide for troubleshooting information.
    Looked at these already:
    KB2690744, Configuring the SharePoint 2010 Management Pack for System Center Operations Manager. 
    http://om2012.wordpress.com/2013/05/24/sharepoint-2010-mp-on-scom-2012/
    Further, if the xml push does have the command get-farm instead of get-spfarm, that could be the issue. i.e.
    http://www.scom2k7.com/advanced-troubleshooting-of-the-sharepoint-2010-mp/
    Thanks,
    +Tony
    Please click "Propose As Answer" if a post solves your problem or "Vote As Helpful" if a post has been useful to you.

    Peter,
     I recommend to remove the Windows 2012 R2 server out of the farm and redeploy on W2008 R2.
    This issue does not have an easy fix.
    Summarizing, this appears to be the issue:
    1. Windows Management Framework 3.0 is integrated with Windows 2012 R2, which installs .NET 4 and Powershell 4.0. Not uninstallable.
    2. The Add-PSSnapin Microsoft.SharePoint.PowerShell is not supported with Powershell 4.0.
    3. The SCOM SP2010 MP puts a package on the defined farm server and when the agent launches the package, it calls Powershell (v4 in theis case) and errors out. The target W2012 server will have an Error 0 in the Operations Manager Event log. See below.
    Options:
    1. Work around maybe - Develop method for manual discovery (I'm working on that now).
    2. Rebuild SP2010 farm on Windows 2008 R2
    3. System Center Team - Write a new MP to down version Powershell (Powershell.exe -Version 2)
    4. Powershell Team - Write a SharePoint Snapin for Powershell 4
    Please click "Propose As Answer" if a post solves your problem or "Vote As Helpful" if a post has been useful to you.

  • Some of the SQL Server 2012 are not getting monitored in SCOM 2012 SP1.( basics monitoring is happening, expect SQL role)

    Found that all the SQL servers are getting monitored, expect few servers which are having SQL server 2012 role.
    proxy is enabled for these servers, when I checked discovered inventory for SQL 2012 database unable to find these servers in that list.
    and other servers having SQL Server 2012 monitoring properly issue is with only few servers.

    Hi,
    thanks for the all the input, we are using service account as windows account instead of action account !!
    will that also affect discovery of SQL role?
    and also found that there are many alerts in SCOM console, with alert description :
    SQL Server cannot authenticate using Kerberos because the Service Principal Name
    (SPN) is missing, misplaced, or duplicated.
    please let me know how we can resolve this issue, will it affect SQL discovery as well ?

  • How to configure windows services alerts in SCOM 2012 for all agent servers. For eg, Terminal Services, Netlogon, RPC etc..

    Hi,
    I need to configure different windows services alerts in SCOM 2012. Below are some of the windows services I need to monitor through SCOM.
    Serivce: Windows Management Instrumentation
    Service: Netlogon
    Service: Remote Procedure Call (RPC)
    Service: Server Service
    Service: Terminal Services
    Service: Windows Time
    Service: Workstation
    Service : WWW Publishing Service
    Could some one please assist or share me the details, how to configure these services for windows agent servers.
    Thanks..
    Regards, Rajeev Parambil

    Hi,
    A certain set of services are monitored by default on all agents:
    DNS Client
    DHCP Client
    RPC
    Workstation
    Server
    For all the other services you could create a service monitor.
    A nice blog series outlining this process can be found here: http://www.bictt.com/blogs/bictt.php/2011/03/16/scom-monitoring-a-service-part1
    It's doing common things uncommonly well that brings succes. Check out my SCOM link blog:
    SCOM link blog

  • Dell server hardware component monitoring with scom 2012 R2.

    hello ..
    We have some dell poweredge r710 SFF 2X SIX CORE X5 SAS Servers ,I need to monitor its hardware components with scom2012 R2.I have installed os:windows server hyper-v server on this and windows server core OS management packs on scom and monitoring
    working fine  .next I want to know their is Latest Management pack available for this  dell model server and what are hardware components can be monitored with scom 2012 R 2. I want to monitor Hardware failure such as   Power failure ,cpu failure,disk
    failure and NIC failure etc
    Thanks
    Richa

    Hi,
    Please refer to the User’s Guide of the DELL MP:
    http://support.dell.com/support/edocs/software/smconect/msscom/40/en/ug/pdf/Dell_Server_Management_Pack_Suite_v4.0_UG.pdf
    Please Note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Meanwhile, considering this is related to DELL products, if you need more information or further investigation, please also contact DELL support
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SQL Server 2012 AlwaysON Monitoring using SCOM

    Team,
    We have SCOM deployed and is serving as a monitoring solution for our SQL Estate. However I want some pointers to monitor the health of DBs within Avaialibility Group like DB Sync, log queue etc. Please direct me with the AlwaysOn health parameters that
    can be monitored by SCOM. 
    I have confirmed with SCOM admin that we have the latest management pack installed for SQL 2012 and currently its getting monitored. However we are not seeing any alerts though.
    Your inputs are highly appreciated.
    Regards,
    Sharath

    The below link might be useful
    http://blog.islamgomaa.com/?p=273
    http://thoughtsonopsmgr.blogspot.com/2012/04/updated-mp-sql-server-monitoring-mp.html
    --Prashanth

Maybe you are looking for

  • Application Realm Issue

    WLS 8.1 SP5 I nominate a realm in application.xml. This realm is not the default realm. The reason is that I want the WLS authenticiation base (admin etc) away from the app realm. Consequently, the realm is not recognised when the app is deployed. Wh

  • Error on result page.

    Hello there, I'm doing a search and results page for my DB, I did the recordset on the results page and the form on the search page as explained in the DW's Docs but when I try a search I get this error: Parse error: syntax error, unexpected ')', exp

  • Bluetooth reconnection

    I have a T420 with bluetooth and it pairs to my phone without any trouble.  All the features work as expected so no complaints there. My only problem is that if I move my phone out of range, the BT link disconnects and does not reconnect automaticall

  • PreparedStatement and use of IN operator

    Hi, I created a PreparedStatement as follows: PreparedStatement ps = conn.prepareStatement("SELECT COLUMNX FROM TABLEX WHERE COLUMNX IN (?)"); where COLUMNX is a simple integer column (primary key) I then assign a value to the placeholder as follows:

  • Tried to upgrade a IBook G4 to FireFox 4.0 and could not make it work, is 4.0 not supported on this older machine?

    Per instructions I tried to upgrade to FireFox 4.0 on my older iBook G4 and would not open. The FireFox logo had a white circle imposed on it. I was really stuck with the older version gone, and the newer one would not work. I managed to copy an olde