Is the PXIe-PCIe8361 adequate for this system? And external clock questions...

Hi all,
I have spent some time piecing together a system and I'd like a sanity check before pulling the trigger on this purchase.  The system will contain the following hardware:
1. Chassis: PXIe-1078
2. Controller: PXIe-PCIe8361
3. 3 x PXIe-6363 (16 analog inputs each card, 32 digital inputs each card, all internally clocked @ 10kHz)
4. 2 x PXI-6224 (32 digital inputs on one, 8 digital inputs on the other, externally clocked in "bursts" of 62.5khz)
5. Labview software
The three PXI-6363 cards will be responsible for  a mix of analog and digital measurements made @ 10 kHz, timed continuously by the onboard clock.
One PXI-6224 will be clocked externally @ 62.5 kHz and will be used to collect digital data on a 32-bit port.  These clock pulses will not be continuous, but will occur in bursts lasting for 2ms every 20ms.
The other PXI-6224 will be clocked externally @ 62.5kHz as well and will be used to collect digital data on an 8-bit port. These clock pulses will not be continuous, but will occur in bursts lasting for 2 ms at random intervals.
My questions are:
1. Am I planning anything that looks unreasonable for this hardware?
2.  Should I expect issues with data transfer rates with the PXIe-PCIe8361?  I will be operating well within the advertised 110MB/s throughput of the device.  I plan to stream this method... NI Fast TDMS data streaming
3.  I have only ever used NI cards for continuous measurements made by an onboard clock.  When I set up a task to collect data that is externally-timed, will the DAQ be expecting a "continuous" clock pulse, or will the system wait patiently for clock pulses to arrive at any rate (any rate within the spec of the card, of course)?
Thanks, any input is appreciated.

Hello LucasH0011
1-As long as you put the PXI-6224  and the PXIe-6363 cards in the corresponding slots, meaning the express(PXIe-6363) in the express and the hybrid(PXI-6224) in the hybrid.
2-I think you would  not have issues with the transfer rate.
3-Your timing specifications sound reasonable to me, I think you will be fine. 
Here is a document that has useful concepts for the use of cards:
http://www.ni.com/white-paper/3615/en/
It is for the M-Series, but the concepts apply to the X-Series as well. 
Regards 
Ernesto

Similar Messages

  • The device failed to calibrat the laser power level for this media

    Hi,
    Does anyone knows what this means:
    "the device failed to calibrat the laser power level for this media"
    And, any selutions for it?
    Thinks.
    Ed

    Pure voodoo, but heck, it's worth a try!
    Just to simplify:
    Open System Preferences.
    Click on "International"
    Under "Languages": Drag any of the other languages to the top,
    then drag English back to the top.
    Set "Order for sorted lists" to English
    Set "Word Break" to English (United States, computer)
    Close System Preferences
    Restart computer
    Thanks Greg!

  • FF not connecting to web- This "Network Connections" message pops up: Error 623: The system could not find the phone book entry for this connection. Any ideas?

    About a month ago I could no longer connect to the internet on our PC. Every time I clicked on the Firefox icon the Netscape sign-on window would pop up. I would try to close it but it would pop up over and over again. If I tried to close it a dozen or so times eventually Firefox would open up but it would never connect. Just today I moved my Netscape file to the recycle bin. No longer does the Netscape sign-on window pop up but following Network Connection error message pops up: "Error 623: The system could not find the phone book entry for this connection".. This error window behaves the same way the Netscape sign-on window used to behave. Every time I click to close it it pops open again. After numerous clicks Firefox opens up but it never connects.

    Do you have this error message on a Mac computer or on a Windows computer?
    I've only seen this error mentioned on a Windows computer.
    *http://kb.mozillazine.org/Autoconnect

  • SOLVED - BIOS UPDATE "SYSTEM DOES NOT CONTAIN the NECESSARY WMI SUPPORT for this VERSION of HPQflash

    If you get infamous error when updating HP Portables (laptops/notebooks/ netbooks) BIOS within Windows:
    "SYSTEM DOES NOT CONTAIN THE NECESSARY WMI SUPPORT FOR THIS VERSION OF HPQFLASH":
    I am posting a solution found for own business laptop (HP 8540W & 8760W) so WebSearch engines index/register it in a few days - future sufferers come here and get a SOLUTION, finally.  Disreagrd previous "experts" advises, they don't work 100% & pity on TechSupport folks who get HP paychecks yet don't know products their co. designs/manufactures (on deep Technical level):
    Below is a SOLUTION (WORKING) !
    Go into Services (Run "services.msc" or get there thru ControlPanel-->AdminTools-->), find following 2 services ==> make sure they're running, chances are they're NOT (as in my case I keep them disabled unless need running):
    1) "HP Software Framework"
    2) "HP Service" [no typo - a real plain name]
    If not running, set Properties-->Manual and click "Start", make sure both are running.
    Rerun BIOS updater, choose option for "Within Windows" or something to that effect (using HPQ/ROMpaq updater), rather than "create USB BootDisk on Key", this time it should work without the hassle of a BootDisk creation.
    Should work from within Windows environment.
    Notes:
    a) Likely only one (1) service is responsible - namely "HP Software Framework" for HPQ Updater to fail, but doesn't hurt to reenable/restart both services.
    I in fact am responding to other customers who elect to Update BIOS within Windows, perhaps oldfashioned but to me Boot Updater is more natural & always works regardless of WMI Support.
    b) After done, don't forget:
    *) Recheck BIOS settings - update may've added new and/or changed old, so rescan tobe sure.
    **) Go BACK into Windows-->Services.msc & redisable both aforementioned Services if were originally disabled; or you're a computer Pro, you know what you're doing & like me keep all HP services disabled.  The ones we got on EliteBook 8760W are pests consuming system resources, you just enable "Software Framework" when occasional issues emerge with HP softupdate (typically no issues) & redisable after use, rest of services are bloatware - some attempt to overrun Windows Wireless console, some seekout HP Networked printers (Ethernet, Wireless, but not USB), some do this & that - I study/know which one does what and decided to disable all. This is called a "minimalist" philosophy & turns your machine into a fast beast, I recently sold a very obsolete 4-year laptop which however handles 3DMCAD & complex designs/simulations, better new machines out fo a store, as new machines are loaded w/bloatware chocking down resources.
    BUT nobody is requiring you to disable anything though.
    The solution merely states the fact:
    These 2 (or 1) services when not running halt BIOS Update "within Windows" (you can still run "BootDisk option", however, if preferred).
    Simply restartung them solves your problem.  Usually
    Ya'll have a good day and enjoy!
    ===========
    BELOW ARE IMPORTANT WARNINGS:
    1) IF YOUR BIOS UPDATE STILL FAILS, SOME OTHER PIECE IN WMI SUPPORT IS MISSING - IN MY CASE WAS THESE 2 SERVICES, BUT THERE'S REMOTE POSSIBILITY SOMETHING ELSE MIGHT BLOCK UPDATER.  DON'T WASTE TIME & CHOOSE "USB/BootDisk" options instead
    2) Once BIOS updater does its job, will ask to auto-restart - let it go on & complete, it will self-shutdown (click "Next" to skip 60-second timer), then do NOT turn it on manually!, wait - it'll turn on by itself in 15 seconds, let it boot into Windows, you're done!
    3) WARNING: close other apps before proceeding, be 100% sure your ACpower won't be interrupted or better yet - make sure battery is in/charged (so if ACpower accidentally disconnects, you're autoswitched onto battery) b/c power loss may result in severe damage to internal hardware.  In the old days it'd result in fatal damage, these days powerloss would still result in a major repair (ROM chip corruption).
    So to summarize: those 2 services I specified, are often responsible for whether HPQ/ROMpaq will or won't run.
    Other causes possible, but I've not witnessed; and if so - choose BootDisk option.
    ===
    Stan M. Starinski, MSEE.

    Hello Ceramics.
    Your ProBook is an Enterprise model.  It would be a good idea to also post your question to the HP Business Boards as those forums deal specifically with that kind of product.  Here is a link.
    Have a great day!
    Please click the white star under my name to give me Kudos as a way to say "Thanks!"
    Click the "Accept as Solution" button if I resolve your issue.

  • HT4623 I have an IPad Model MC497LL with version 4.2.1 (8C148) where do I find system updates to get this device to the highest version possible for this model?

    I have an IPad Model MC497LL with version 4.2.1 (8C148) where do I find system updates to get this device to the highest version possible for this model?

    Go back to the article you asked this question from, ignore the instructions for updating it wirelessly, scroll down, and follow those for updating it from iTunes on a computer.
    (93330)

  • My Extensis suitcase 11.0.4 is no longer working with my system OSX10.6.8, what is the best and cheapest font management software to use that's compatible with this system and CS software

    my Extensis suitcaseX 11.0.4 is no longer working with my system OSX10.6.8, what is the best and cheapest font management software to use that's compatible with this system and my existing CS design software?

    If you upgraded to Snow Leopard, then it would seem that Suitcase 11 is not compatible with Snow Leopard and you'd need to buy Suitcase Fusion 3 for $99.95.

  • How to find the when the password is changed for a system User

    Hi to all,
    We have a test database where our application connects to system user. The application runs more than a month without any issues, But suddenly my system and sys password gets changed. I wonder how this would happen. I have checked with DBA_USERS to check whether the account gets locked, But the account is in the Open state.
    I need to find out when the password gets changed for these users and who changed it? Is there any possible to trace it or we need to enable the auditing to find it in future.
    Kindly let me know the possible ways.
    Regards,
    Vijayaraghavan K

    Vijayaraghavan Krishnan wrote:
    Hi to all,
    We have a test database where our application connects to system user. The application runs more than a month without any issues, But suddenly my system and sys password gets changed. I wonder how this would happen. I have checked with DBA_USERS to check whether the account gets locked, But the account is in the Open state.
    I need to find out when the password gets changed for these users and who changed it? Is there any possible to trace it or we need to enable the auditing to find it in future.
    Kindly let me know the possible ways.
    Regards,
    Vijayaraghavan KThe only way to implement an Oracle Audit

  • What Is The Proper J2EE Architect For This National Defense Project?

    A brief description of a national defense project I am looking into is that the system being developed is supposed to verify the "smartcard" of the card holder and his/her fingerprints against the Defense Department database. The system also reads in information about people (facial features, height, weight, etc.) and stores the information in the database, and then issues new "smartcard".
    1. People involved in the project already decided to use swing for the client tier.
    2. The problem is the Defense Department database. It is a flat file database and this database cannot be touched. It is a black box for Java developers. The Defense Department may provide a jar as an outer layer of this database.
    Question 1: Is the web tier essential for this defense project?
    Question 2: What is the proper J2EE architect for this project?
    Question 3: How to deal with the data problem? Especially it looks that entity beans are not applicable.
    Question 4: How does the system handle very heavy load? It is possible that tens of thousands of people will use the system at the same time.

    A brief description of a national defense project I am
    looking into is that the system being developed is
    supposed to verify the "smartcard" of the card holder
    and his/her fingerprints against the Defense
    Department database. The system also reads in
    information about people (facial features, height,
    weight, etc.) and stores the information in the
    database, and then issues new "smartcard".
    1. People involved in the project already decided to
    use swing for the client tier.
    2. The problem is the Defense Department database. It
    is a flat file database and this database cannot be
    touched. It is a black box for Java developers. The
    Defense Department may provide a jar as an outer layer
    of this database.
    Question 1: Is the web tier essential for this defense
    project?
    Question 2: What is the proper J2EE architect for this
    project?
    Question 3: How to deal with the data problem?
    Especially it looks that entity beans are not
    applicable.
    Question 4: How does the system handle very heavy
    load? It is possible that tens of thousands of people
    will use the system at the same time.
    Hi,
    You can get it done here :http://www.thesoftwareobjects.com

  • Logical system name has been changed for this system

    Hi gurus,
    I am fasing problem in BI7 system. we created a new client in the system & want to set it for BI development.
    System Response
    The transaction is canceled.
    Procedure
    Change the name of the logical system (table T000) for client  back to BID500. This enables you to continue working with the system.
    If you really want to change the logical name, than you can, if and when you:
    change the system name back to BID500,
    delete all existing connections between this system and other systems,
    delete all transfer structures that still exist, and
    do not use ALE or Workflow.
    Regards,
    Darshan..

    Sorry, BI is a one client system. You cannot have a prod client and a dev client within one SAP system.
    But...
    ...NO, you can't!
    Best regards
    Michael
    EDIT: just to add, there is an exception if you have a SCM/APO type system [522569 - BW: Working in several clients (especially APO 4.x/SCM 4.x)|https://service.sap.com/sap/bc/bsp/spn/sapnotes/index2.htm?numm=522569]

  • No JRE version found in launch file for this system

    Hi,
    I have an application which is launched by JWS.
    When we use JWS from 1.4, it runs fine. But JWS from 1.5.0_15 gives the error "No JRE version found in launch file for this system"
    In both the JWS(1.4 and 1.5.0_15)cases, we install JRE1.5.0_15 using the installer and used for invoking the application.
    We invoke mailclient.jnlp, which inturn invokes the installer.jnlp and KanaJreInstaller.asp
    <<mailclient.jnlp>>
    <?xml version="1.0" encoding="utf-8"?>
    <jnlp
    spec="1.0"
    codebase="http://mpshanmu-gx520:80/10r3/"
    href="mailclient.jnlp">
    <information>
    <title>KANA Agent</title>
    <vendor>KANA Software, Inc.</vendor>
    <homepage href="http://www.kana.com"/>
    <description>KANA Suite 10.3.0</description>
    <icon href="images/mail_logo.gif"/>
    <offline-allowed/>
    </information>
    <security>
    <all-permissions/>
    </security>
    <resources>
    <j2se version="KANA1.5.0_15" href="KanaJreInstaller.asp"/>
    <jar href="lib/mailclient_s.jar"/>
    <jar href="lib/link_s.jar"/>
    <jar href="lib/spell_s.jar"/>
    <jar href="lib/ssce_s.jar"/>
    <jar href="lib/kc_framework_s.jar"/>
    <jar href="lib/kc_sharedGUI_s.jar"/>
    <jar href="lib/xalan_s.jar"/>
    <jar href="lib/xerces_s.jar"/>
    <jar href="lib/java2com_s.jar"/>
    <jar href="lib/jgl3.1.0_s.jar"/>
    <jar href="lib/rsrcbundle_s.jar"/>
    <jar href="lib/response_s.jar"/>
    <jar href="lib/HTMLEditorEnterprise_s.jar"/>
    <jar href="lib/jakarta-oro-2.0.4_s.jar"/>
    <jar href="lib/jdic_s.jar"/>
    <extension name="Sun Libraries" href="sunextensions.jnlp"/>
    </resources>
    <resources os="Windows">
    <nativelib href="lib/windlls_s.jar"/>
    <nativelib href="lib/jdic-native.jar"/>
    </resources>
    <application-desc main-class="kana.mail.wkstn.AppMain">
    <argument>-serverlist</argument>
    <argument>http://mpshanmu-gx520:80/10r3/servers.xml</argument>
    </application-desc>
    </jnlp>
    <<KanaJreInstaller.asp>>
    <%@ language="vbscript"%>
    <%
    Response.ContentType="application/x-java-jnlp-file"
    Response.AddHeader "x-java-jnlp-version-id","KANA1.5.0_15"
    dim fs,f,ts
    set fs=Server.CreateObject("Scripting.FileSystemObject")
    Set f=fs.GetFile("C:\Program Files\KANA\KANA Response Web Server_10r3\installer.jnlp")
    Set ts=f.OpenAsTextStream(1)
    Response.Write(ts.ReadAll)
    ts.Close
    set ts=nothing
    set f=nothing
    set fs=nothing
    %>
    <<installer.jnlp>>
    <?xml version="1.0" encoding="utf-8"?>
    <jnlp
    spec="1.0"
    codebase="http://mpshanmu-gx520:80/10r3/"
    href="installer.jnlp">
    <information><title>KANA J2RE 1.5.0_15 Installer</title>
    <vendor>KANA Software, Inc.</vendor>
    </information>
    <security>
    <all-permissions/>
    </security>
    <resources>
    <j2se version="1.3+"/>
    <jar href="lib/installer.jar"/>
    <jar href="lib/JRE_KANA1.5.0_15.jar"/>
    <property name="jre.container" value="JRE_KANA1.5.0_15.jar"/>
    <property name="jre.execute" value="bin\\javaw.exe"/>
    <property name="jre.version" value="KANA1.5.0_15"/>
    </resources>
    <installer-desc main-class="JREInstaller"/>
    </jnlp>
    Thanks

    >
    We are using sun JRE(1.5.0_15) only. We extract Sun JRE and build it as KANAJRE.jar and signing.>I have never heard of KANAJRE. Would you care to post a link to the site, or should we just keep guessing? (My patience for random guesses is running out.)
    >
    We install using Intaller class and that is getting listed in the Java Control panel and enabled too.>List as what?
    Does it list it with the entire string "KANA1.5.0_15" or is is just listed as "1.5.0_15"?
    Because this line from the JNLP file..
    <j2se version="KANA1.5.0_15" href="KanaJreInstaller.asp"/>..had me convinved it was a non-Sun JRE. Not so much the href, but most especially the version attribute.
    If it really is the Sun JRE, I would expect this to work.
    <j2se version="1.5.0_15" href="KanaJreInstaller.asp"/>And as an aside. If this installer is giving you trouble and the app. requires the 1.5.0_15 JRE, why not simply the default Sun JRE installer? What advantages do you think this installer offers?

  • How to Hold/Block the messages in PI for particular system

    Hi,
    I want to know the way of holding/blocking the message in PI for particular system. For other system message flow should happpened normally. My Scenario is,
    R3->PI->SRM. For connection between PI and SRM we are using proxy. We are going to upgrade our SRM system. During that time there should not be any message flow to  SRM. All the message needs to be blocked in PI. Once the upgrade over, we will restart all the messages.
    There are lot more system connected to PI. There should not be any interupt on that, message flow should happned normally for other system except SRM. Only the message going to SRM should be blocked.
    I found one way, by locking the user which used in communication channel for SRM system. So all the message will be failed in PI with Authentication error. After upgrade we can restart the message.
    Is there any other standard way to hold/block the messages which are going to particular system??
    Regards
    Baskaran K

    Hi,
    > I found one way, by locking the user which used in communication channel for SRM system. So all the message will be failed in PI with Authentication error. After upgrade we can restart the message.
    By locking user or giving wrong password to RFC destination in PI or by giving wrong business system in Receiver determination we can stop the messages in PI. But those failes messages are available for only few days in SXMB_MONI based on the BASIS settings.
    But I don't think this is the best way, we have other alternative is we can save those files in one folder, after upgrade by using some other scenario we can process the files.
    Regards,
    Venkata Ramesh

  • 880GM-E43 - What is the "real" maximum memory for this mobo?

    Hi,
    I have a system that I built awhile ago that uses the 880GM-E43 mobo.  At the time that I built this system, everything that I found indicated that the max memory was 16GB (4 x 4GB), which is what I have installed now.
    I've been wanting to have more memory (lots of VMware guests), so I've been starting to look at building a new system, which I thought would have required a different mobo that supports 32GB (4 x 8GB) and a new set of 8GB memory sticks.
    While I was researching that, I found this:
    http://www.msi.com/product/mb/880GM-E43.html
    and under the Specifications tab, it says:
    Code: [Select]
    DDR3 Memory DDR3 800/1066/1333/1600*(OC)
    DDR2 Memory N/A
    Memory Channel Dual
    DIMM Slots 4
    Max Memory (GB) 32 
    Everywhere else, other than the MSI website itself, still seems to say "16GB" max.
    Does anyone know which maximum is correct?  Is it 16GB, or is it 32GB?
    Please advise.
    Thanks,
    Jim

    Quote from: Bas on 02-January-12, 23:48:42
    It's only limited to what the CPU can handle, and that is far more then you can buy at this time
    However, MSI only tested at the time of production of the board.
    So if you use bigger modules you have to test yourself if it works with your CPU, the board got nothing to do with it.
    What ever you do, don't mix sizes and brands, often goes wrong.
    Bas,
    Not doubting what you said, but I hope that's the case.  Will post back as soon as it gets in and I get a chance to test it.  As you suggested, I'll initially remove the 4x4GB sticks, and replace them with the new 2x8GB sticks, and see how that works.  If it that works, I'll put in the additional 2x4GB (understood what you said, but this is interim).
    Then, if that works, I can wait for maybe prices to drop to get an additional 2x8GB kit, but going to 24GB will help a lot with the work that I'm doing (mostly Vmware guests).
    Jim

  • Debliery Units : VENDOR IS NOT DEFINED FOR THIS SYSTEM

    Dear Experts,
    In prespective modeler , tried creating 'DELIVERY UNITS'. However get error message
    "CANNOT CREATE DELIVERY UNIT AS CONTENT VENDOR IS NOT DEFINED FOR THIS SYSTEM" ?
    How can we maintain CONTENT VENDOR ? we are using in-house HANA installation.
    Regards
    Prashant

    Hi Shrikant,
    Please do not reply with your same question in all of the threads which are answered.
    What is the version you are using?
    Where exactly you are unable to see?
    Once you edited the field as mentioned by Jody, it will be in green circle. Also while creating the package, you can see this DU as shown below:
    Regards
    Raj

  • Unable to connect to the Data Access service for this management server

    Hate to raise a sleeping horse but was hoping someone might have some insight into why SCOM Report Server install is failing. I am using a domain account for SCOM 2012 R2 services in a distributive environment
    with 2 management servers and 2 SQL servers…one for Ops db and one for DW db.
     Install was failing on selecting the management server. Research led me to
    Kevin Holman's site. I followed his doc and SPN are set per your config and can telnet to MGMT1 on 5723…firewall is off on all servers. I am a domain admin and scom.mgmt account (MSOMSdkSvc) is a local admin on the MGMT servers.
    >setspn -l domain\scom.mgmt
    Registered ServicePrincipalNames for CN=scom.mgmt,OU=Service Accounts,DC= domain,DC=net:
    MSOMSdkSvc/SCOM-MGMT1
    MSOMSdkSvc/SCOM-MGMT1.domain.net
    MSOMSdkSvc/SCOM-MGMT2
    MSOMSdkSvc/SCOM-MGMT2.domain.net
    >setspn -l domain\scom-mgmt1
    Registered ServicePrincipalNames for CN=SCOM-MGMT1,OU=SCOM,OU=INTERNAL,DC=domain,DC=net:
    MSOMHSvc/SCOM-MGMT1.domain.net
    TERMSRV/SCOM-MGMT1.domain.net
    WSMAN/SCOM-MGMT1.domain.net
    RestrictedKrbHost/SCOM-MGMT1.domain.net
    HOST/SCOM-MGMT1.domain.net
    MSOMHSvc/SCOM-MGMT1
    TERMSRV/SCOM-MGMT1
    WSMAN/SCOM-MGMT1
    RestrictedKrbHost/SCOM-MGMT1
    HOST/SCOM-MGMT1
    >setspn -l domain\scom-mgmt2
    Registered ServicePrincipalNames for CN=SCOM-MGMT2,OU=SCOM,OU=INTERNAL,DC=domain,DC=net:
    MSOMHSvc/ SCOM-MGMT2.domain.net
    MSOMHSvc/ SCOM-MGMT2
    WSMAN/SCOM-MGMT2.domain.net
    WSMAN/SCOM-MGMT2
            TERMSRV/SCOM-MGMT2.domain.net
    TERMSRV/SCOM-MGMT2
    RestrictedKrbHost/SCOM-MGMT2
    HOST/CHH-SCOM-MGMT2
    RestrictedKrbHost/CHH-SCOM-MGMT2.osi-asp.net
    HOST/CHH-SCOM-MGMT2.osi-asp.net
    >setspn -l domain\scom-ssrs
    Registered ServicePrincipalNames for CN=SCOM-SSRS,OU=SCOM SQL,OU=SCOM,OU=CHH-INTERNAL,DC=domain,DC=net:
        WSMAN/SCOM-SSRS
    WSMAN/SCOM-SSRS.domain.net
    MSSQLSvc/SCOM-SSRS.domain.net
    MSSQLSvc/SCOM-SSRS.domain.net:1433
        TERMSRV/SCOM-SSRS.domain.net
    TERMSRV/SCOM-SSRS
    RestrictedKrbHost/SCOM-SSRS
      HOST/SCOM-SSRS
    RestrictedKrbHost/SCOM-SSRS.domain.net
    HOST/SCOM-SSRS.domain.net
    When I point to the MGMT server, I keep getting “Unable to connect to the Data Access service for this management server. Ensure the Data Access service is running and that the service, the management group, and setup are
    all the same version”.
    OpsMgrSetupWizard.log states…
    Info:     
    :Could not connect to Management Server: scom-mgmt1.domain.net with exception: Threw Exception.Type: System.ArgumentException, Exception Error Code: 0x80070057, Exception.Message: Version string portion was too short or
    too long.
    Info:     
    :StackTrace:   at System.Version.TryParseVersion(String version, VersionResult& result) at System.Version..ctor(String version) at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SetupHelpers.IsManagementServerCurrentVersion(String
    managementServer) at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SetupHelpers.CanConnectToManagementGroup(String managementServer)
    When I searched on "Exception.Message: Version string portion was too short or too long" it led me to .Net strings in the reg. i deleted all refs to older versions (3.x) but still no good.
    Bob

    Well, I’m back to trying to get SCOM Report Server up and running. This time I decided to try the command line silent install and rely on logs to debug. But it still fails.
    This is the script: SETUP /install /InstallPath:D:\Program Files\Microsoft System Center 2012 R2\Operations Manager /components:OMReporting /ManagementServer:<server>.<domain> /SRSInstance:<instance> /DataReaderUser:<domain>\<account>
    /DataReaderPassword:******** /SendODRReports:0 /UseMicrosoftUpdate:0 /AcceptEndUserLicenseAgreement:1
    When I run the script, I get a pop-up: “System CenterOperations Manager Setup has stopped working with the following:
    Problem signature:
    Problem Event Name:                       
    CLR20r3
    Problem Signature 01:                      
    setupchainerui.exe
    Problem Signature 02:                      
    7.0.5000.0
    Problem Signature 03:                      
    522a5b85
    Problem Signature 04:                      
    mscorlib
    Problem Signature 05:                      
    4.0.0.0
    Problem Signature 06:                      
    53b4fc1e
    Problem Signature 07:                      
    e4d
    Problem Signature 08:                      
    5a
    Problem Signature 09:                      
    System.FormatException
    OS Version:                                         
    6.1.7601.2.1.0.274.10
    Locale ID:                                            
    1033
    Additional Information 1:                 
    4911
    Additional Information 2:                 
    49111a576c61a461b7f2900e4224563c
    Additional Information 3:                 
    a1e6
    Additional Information 4:                 
    a1e62e9c159c1d7601a31ccff83dbf94
    App Event Log:
    - <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
    - <System>
    <Provider Name=".NET Runtime" />
    <EventID Qualifiers="0">1026</EventID>
    <Level>2</Level>
    <Task>0</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime="2015-01-29T19:02:39.000000000Z" />
    <EventRecordID>4999</EventRecordID>
    <Channel>Application</Channel>
    <Computer>SERVER NAME</Computer>
    <Security />
    </System>
    - <EventData>
    <Data>Application: SetupChainerUI.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception.
    Exception Info: System.FormatException Stack: at Microsoft.SystemCenter.Essentials.SetupFramework.Program.Main()</Data>
    </EventData>
    </Event>
    - <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
    - <System>
    <Provider Name="Application Error" />
    <EventID Qualifiers="0">1000</EventID>
    <Level>2</Level>
    <Task>100</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime="2015-01-29T19:02:41.000000000Z" />
    <EventRecordID>5000</EventRecordID>
    <Channel>Application</Channel>
    <Computer>SERVER NAME</Computer>
    <Security />
    </System>
    - <EventData>
    <Data>SetupChainerUI.exe</Data>
    <Data>7.1.10226.0</Data>
    <Data>522a5b85</Data>
    <Data>KERNELBASE.dll</Data>
    <Data>6.1.7601.18409</Data>
    <Data>5315a05a</Data>
    <Data>e0434352</Data>
    <Data>000000000000940d</Data>
    <Data>a64</Data>
    <Data>01d03bf626a03a7a</Data>
    <Data>C:\Users\USER NAME\AppData\Local\SCOM\Setup\SetupChainerUI.exe</Data>
    <Data>C:\Windows\system32\KERNELBASE.dll</Data>
    <Data>65be21be-a7e9-11e4-a4d7-005056966e1b</Data>
    </EventData>
    </Event>
    - <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
    - <System>
    <Provider Name="Windows Error Reporting" />
    <EventID Qualifiers="0">1001</EventID>
    <Level>4</Level>
    <Task>0</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime="2015-01-29T19:03:27.000000000Z" />
    <EventRecordID>5001</EventRecordID>
    <Channel>Application</Channel>
    <Computer>SERVER NAME</Computer>
    <Security />
    </System>
    - <EventData>
    <Data />
    <Data>0</Data>
    <Data>CLR20r3</Data>
    <Data>Not available</Data>
    <Data>0</Data>
    <Data>setupchainerui.exe</Data>
    <Data>7.0.5000.0</Data>
    <Data>522a5b85</Data>
    <Data>mscorlib</Data>
    <Data>4.0.0.0</Data>
    <Data>53b4fc1e</Data>
    <Data>e4d</Data>
    <Data>5a</Data>
    <Data>System.FormatException</Data>
    <Data />
    <Data />
    <Data>C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_setupchainerui.e_9724aaa8eec4ffba07c27fea369e612e949d75_5b269652</Data>
    <Data />
    <Data>0</Data>
    <Data>65be21be-a7e9-11e4-a4d7-005056966e1b</Data>
    <Data>0</Data>
    </EventData>
    </Event>
    OpsMgrSetupWizard.log
    [13:48:16]:          
    Error:     :Uncaught Exception: Threw Exception.Type: System.FormatException, Exception Error Code: 0x80131537, Exception.Message: Input string was not in a correct format.
    [13:48:16]:          
    Error:     :StackTrace:  
    at System.Number.StringToNumber(String str, NumberStyles options, NumberBuffer& number, NumberFormatInfo info, Boolean parseDecimal)
       at System.Number.ParseInt32(String s, NumberStyles style, NumberFormatInfo info)
       at System.Convert.ChangeType(Object value, Type conversionType, IFormatProvider provider)
       at Microsoft.SystemCenter.Essentials.SetupFramework.PropertyBagDictionary.GetProperty[T](String property)
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SetupHelpers.ValidateBureaucraticSwitches()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.RationalizeCommandLineArguments.ValidateSilentInstallCommandLineOptions()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.RationalizeCommandLineArguments.Rationalize()
       at Microsoft.EnterpriseManagement.OperationsManager.Setup.Common.SetupHelpers.RationalizeGeneralInstall()
       at Microsoft.SystemCenter.Essentials.SetupFramework.Program.RationalizeInstall()
       at Microsoft.SystemCenter.Essentials.SetupFramework.Program.Main()
    Any ideas? I feel like I’m just going in circles…Bob

  • Xml contains no components for this system.

    Good Morning Sap Experts
    I am aplying EHP1 to SAP NETWEAVER 7.01 and I get the error
    The stack /usr/sap/trans/SMSDXML_PBI_20100831232419.708.xml contains no
    components for this system.
    Now I review the XML file and the JAVA STACK don't appear in xml file.
    Only appear the ABAP STACK, I tried to recreate the file but the problem persists

    SOLVED, I set the system in solution manager stcode SMSY
    BI 7.0
    1. Create a system component of type Java system with name beginning with the 3 letters of the SID of the j2ee engine where the BI Java is running.
    For software component, click on the from MainInstance button and then select Product SAP Netweaver, Product version = SAP Netweaver 7.0 and Main Instance BI Java.
    2. Enter a system name beginning with the 3 letters ofyour SID (Abap stack).
    Select Product = SAP Netweaver, Product version = SAP Netweaver7.0
    In the table, check the Business intelligence (BI) as relevant.
    Double click on it and enter the Instance and server names. Check the BI Java as relevant and then enter the System
    Component that was previously created in the System component column, and check the box in the system Component Assignment column, in the column type, select Java system.
    3. Recreate XML file and rename it.
    Thanks
    William Neira

Maybe you are looking for

  • "An error occurred while trying to save your photo library..."

    Installed iPhoto6. Started app. It said it would take a few seconds or minutes to upgrade. About 6 hours later after churning on thumbnails it is now claiming this error over and over with some time that goes by in between: "An error occurred while t

  • How is it best to develope a multiple window (front panel) application in LabVIEW?

    I have only been using LabVIEW for a couple months so keep this in mind while I ask this question. I have been testing out multiple ways of developing a application using multiple windows and passing data between them, in LabVIEW. I am not sure how t

  • In the AppStore when I try to download an app which I had deleted it won't let me

    Ok so iv deleted a few apps and when I go into the AppStore to download them again it says installed and it's greyed out even tough the app isn't on my device :/ what should I do?

  • Taking in my MBP

    Hey I have had and have lots of problems with my 2 months old MBP having random hangs and beachballs. I think i've have tried pretty much everything to solve the problem. Permission and disk repairs, PRAM and SMC resets, DiskWarrior, TechTool Pro, Cl

  • Removing my username

    so last night i wanted to rename my username on my macbook pro but ended up removing it i have lost anything files pic videos you name it and system preferences will not open i can not save pic from the internet and i can not find my old username any