Issue in Unicode Conversion

Hi,
We are doing Unicode Conversion activity in one of our system. After running through UCCHECK transaction, we got around 80 programs in which most of them were resolved manually.
kindly find the below screenshot when we are trying to edit one object, we are facing the issue. Any help will be highly appreciated .
Thanks,
Grace

Hi,
Reposting the question again, as earlier one was incomplete.
We are doing Unicode Conversion activity in one of our system. After running through UCCHECK transaction, we got around 80 programs in which most of them were resolved manually. When we are trying to edit one object, the error"Namespace /OSJ8C/' does not exists is displayd. Any help to resolve this issue will be highly appreciated .

Similar Messages

  • Nametab issue during unicode conversion

    There are some tables inconsistent durning Unicode conversion, is it possible to delete them?
    Moderator message: not directly related to ABAP development, please have a look in the Netweaver forums, alway search for information before asking.
    Edited by: Thomas Zloch on Dec 23, 2010 1:32 PM

    Hi,
    Reposting the question again, as earlier one was incomplete.
    We are doing Unicode Conversion activity in one of our system. After running through UCCHECK transaction, we got around 80 programs in which most of them were resolved manually. When we are trying to edit one object, the error"Namespace /OSJ8C/' does not exists is displayd. Any help to resolve this issue will be highly appreciated .

  • Error during unicode conversion

    Dear all,
    we are facing one issue during unicode conversion. the code is as follows:
    FIELD-SYMBOLS : <n> TYPE X,
                                 <c> TYPE C.
    DATA : a TYPE i.
    DATA : x TYPE x.
    MOVE <n> TO a.
    a = a + 22.
    MOVE a TO x.
    ASSIGN x TO <c> CASTING TYPE c
    and we are getting the following error:
    ERROR : the length of "X" in bytes must be a multiple of the size of a Unicode character (regardless of the size of the unicode character
    please guide on how this can be resolved in ECC.
    Regards,
    N.Jain

    Hi,
    here is some code to do it:
    FIELD-SYMBOLS : <n> TYPE x,
                    <c> TYPE c.
    DATA : a TYPE i.
    DATA : x TYPE x.
    MOVE <n> TO a.
    a = a + 22.
    MOVE a TO x.
    DATA:
      buffer TYPE xstring,
      conv TYPE REF TO cl_abap_conv_in_ce,
      x_char.
    buffer = x.
    conv = cl_abap_conv_in_ce=>create(
           encoding = 'NON-UNICODE'
           input = buffer
    CALL METHOD conv->read(
      EXPORTING
        n    = 1
      IMPORTING
        data = x_char
    ASSIGN x_char TO <c>.
    Regards
    Walter Habich
    Edited by: Walter Habich on Jun 10, 2008 4:09 PM

  • Error while database export in package SAPDODS_33 (Unicode conversion)

    Hello,
    I am performing Unicode conversion on an upgraded BI 7.0 system. This is running on AIX/DB2.
    When I take database export for conversion, one package fails (SAPDODS_33) with error "The file system is full". In fact, df -k doesn't show that any file system is full.
    I am taking the export to the following location: /db2/BWS/sapdata/EXPORT_DIR
    There are 3 system-managed temporary tablespaces: PSAPTEMP, PSATEMP16 & SYSTOOLSTMPSPACE which were residing in /db2/BWS/saptemp1/NODE0000. This was getting full during the export. Now these temp.tablespaces have been relocated to a new file system of size 15GB.
    But still the package SAPDODS_33 doesn't get exported. Could you please let me know how to solve this issue?
    Thanks a lot!
    Sundar.
    =====================================================================================
    SAPDODS_33.log
    (DB) INFO: connected to DB
    (rscpsumg) Please look also into "SAPDODS_33012.xml".
    (rscpMC) Warn: env I18N_NAMETAB_TIMESTAMPS = IGNORE
    (rscpMC) Warn: UMGCONTAINER has 1 problems.
    (rscpMC) Warn: Global fallback code page = 1160
    (rscpMC) Warn: Common character set is  not  7-bit-ASCII
    (rscpMC) Warn: Collision resolution method is 'fine'
    (rscpMC) Warn: R3trans code pages = Normal
    (rscpMC) Warn: EXPORT TO ... code pages = Normal
    (rscpMC) Warn: Source is 'MDMP'
    (rscpMC) Warn: I18N_NAMETAB_NORM_ALLOW = 0
    (rscpMC) Warn: I18N_NAMETAB_NORM_LOG   = 0
    (rscpMC) Warn: I18N_NAMETAB_ALT_ALLOW  = 0
    (rscpMC) Warn: I18N_NAMETAB_ALT_LOG    = 0
    (rscpMC) Warn: I18N_NAMETAB_OLD_ALLOW  = 0
    (rscpMC) Warn: I18N_NAMETAB_OLD_LOG    = 0
    (GSI) INFO: dbname   = "BWS
    (GSI) INFO: vname    = "DB6                             "
    (GSI) INFO: hostname = "UNKNOWN
    (GSI) INFO: sysname  = "AIX"
    (GSI) INFO: nodename = "itmlartdev01x"
    (GSI) INFO: release  = "3"
    (GSI) INFO: version  = "5"
    (GSI) INFO: machine  = "002417CA4C00"
    (GSI) INFO: instno   = "0020169337"
    (EXP) ERROR: DbSlExeRead failed
      rc = 99, table "/BIC/B0000786000"
      (SQL error -968)
      error message returned by DbSl:
    SQL0968C  The file system is full.  SQLSTATE=57011
    (DB) INFO: disconnected from DB
    /usr/sap/BWS/SYS/exe/run/R3load: job finished with 1 error(s)
    /usr/sap/BWS/SYS/exe/run/R3load: END OF LOG: 20071211053119
    p/sapinst/sapinst_instdir/NW04S/LM/COPY/DB6/EXP/CENTRAL/AS-ABAP/EXP #

    Hi Sundar,
    if the problem is due to a high temp space usage. The root cause is typically the
    sort during export. If the table is large, the sort spills to temp.
    You can avoid the sort by doing an unsorted export or tweak the DB2 optimizer to use the primary key to do the sort.
    Before DB2 9, you can reduce the OVERHEAD tablespace parameter to zero. Return this value to its previous value after the successful export. This is a indirect hint to the optimizer that random IOs are cheap. This might not help.
    With DB2 9, this should not happen, because the  DB2_OPT_MAX_TEMP_SIZE=10240 registry variable is set under DB2_WORKLOAD=SAP which limits the temp space usage to 10GB if possible. You can reduce this parameter further if necessary. Another problem could be that the optimizer has chosen the wrong temp space. The optimizer choses the temp space with the largest amount of pages (not size).
    Regards, Jens

  • Unicode conversion in situ

    Hi SCN,
    I'm looking at the possibility of running a Combined Upgrade & Unicode Conversion (CUUC) in-situ; i.e. without a migration to new hardware.
    However in all my years of SAP Basis projects any Unicode conversion I've seen has involved a migration to new hardware (which makes good sense as the process is the same as an OSDB migration with R3load/MigMon).
    What I want to know is - has anyone ever run one in-place. I.e. keeping the same server and running the CUUC entirely inplace?
    This seems logically problematic as you need a target system to import to.
    I can imagine a process along these lines though...:
    1. Take SAP layer offline
    2. Run full backup of system
    3. Export system
    4. Drop database* (to make clean ready for new import)
    5. Run SPUMG/SUMG/SAPINST to setup Unicode database ready to receive import...
    6. ....and continue to run import into that database
    7. Complete Unicode conversion process
    However the big issue here for me is
    (a) *dropping the live production system is far from attractive.... I'm presuming everyone would do as I've always seen and combine this with a migration to new improved hardware, so that a backout to the old system is simple
    (b) I'm not sure at what point with the SAP tools (SPUMG/SUMG/SAPINST) this process would become convoluted with it all being in-situ on the same box. I.e. I'm not sure if it's something the SAP tools are really designed to cater for.
    Any input/discussion on these points would be very welcome.
    Regards, doonan_79

    FYI Community. Feeling after reading and research is to use a temorary server to import unicode converted system data into; then swing disks back to the original host. Making all required hostname updates during the process.
    Allowing for parallel export/import, but going back to the original configured host to complete the process.

  • Some character display incorrect after unicode conversion

    Dear Experts,
    Currently we upgrade our SAP system from 4.6B NU to ECC6.0 UN.
    in 4.6B system we had implemented Simple Chinese and French language package to the system. after upgrade to ECC6.0 no-unicode system. we perform a MDMP unicode conversion.currently system running with ECC6.0 unicode interface with language 1EFD. SUMG releated tasks had been finished. Chinese and French language checked OK in ECC6 UN system.
    Our issue is. in the past time. some Spanish local end user typing some spanish character in some master date field when they login in 4.6B GUI choice english as login language.these kind of spanish characters could not display correct in current unicode environment.
    could you please given us some suggestion for how to fix this issue.
    I also sent this message in the Netweaver administrator forums with below links.
    Spanish display incorrect after unicode conversion

    Hello,
    I doubt that the data shown by you in the link was caused by Spanish users logged on in EN.
    I think this was rather caused by utf-8 data uploaded into the Non-Unicode system.
    In this case, you need to repair the according texts manually, I do not know any automatic repair.
    Best regards,
    Nils Buerckel
    SAP AG

  • LRAW data Conversion during Unicode Conversion

    Hi,
    We have upgraded our 46C MDMP system to Unicode system.
    After conversion we found that some of the tables with field of LRAW type are having conversion issue.
    In 46C system, Russian data which enetered in the MS Cyrillic (Code page 1504), is converted to code page 1500 after unicode conversion.
    We have not found any entries for this table in vocabulary, reprocess log or in SUMG.
    For example table STXL. This table contains Purchase order text for the material.
    Report HRUU_CONVERT_IN_UNICODE does not shows LRAW data field for conversion.
    Can you suggest how LRAW data can be converted from 1500 to 1504 code page.
    Thanks and Regards
    Rahul

    Hi Rahul,
    STXL is a language dependent INDX type table. Hence SPUMG will not scan this one with the default settings.
    Please have a look at the description of INDX type table handling in the Unicode conversion Guide.
    In the Unicode system, you can use UMG_ADJUST_STXL for the conversion.
    However please be aware of the restrictions:
    Once you have decided about the code page and converted the object, this cannot be reverted !
    Therefore it is highly recommended to check the display mode first and in addition test it extensively on a sandbox system !
    Best regards,
    Nils Buerckel
    SAP AG

  • BAPI Receives unreadable parameters after unicode conversion

    Dear All,
    I have a strange issue, which i am stuck with and need your help to solve this.
    I have a BSP Application which resides in my BW Production system and it calls a custom BAPI in R/3 to fetch list of materials based on material-text search as one of the parameters. This used to work properly before our R/3 got upgraded to ECC 6.0 with unicode conversion.
    Both BW and R/3 are unicode systems now. But, doing external debugging i found that the parameters that i am sending through BSP to this BAPI are ok on BW side but, when it reaches R/3 it is getting converted to some unreadable characters due to which the BAPI doesnot return correct results.
    Please advice where does conversion is happening and how can this be solved. I need immediate help as I am helpless and its a production issue...
    Thanks,
    Chandan

    Hi Chandan,
    please make sure that in transaction SM59 on both sides (BW and ERP) the rfc connections are defined as Unicode.
    Best regards,
    Nils Buerckel
    SAP AG

  • Spanish display incorrect after unicode conversion

    Dear Experts,
    Currently we upgrade our SAP system from 4.6B NU to ECC6.0 UN.
    in 4.6B system we had implemented Simple Chinese and French language package to the system. after upgrade to ECC6.0 no-unicode system. we perform a MDMP unicode conversion.currently system running with ECC6.0 unicode interface with language 1EFD. SUMG releated tasks had been finished. Chinese and French language checked OK in ECC6 UN system.
    Our issue is. in the past time. some Spanish local end user typing some spanish character in some master date field when they login in 4.6B GUI choice english as login language.these kind of spanish characters could not display correct in current unicode environment.
    could you please given us some suggestion for how to fix this issue.

    Hello Anil,
    Below items we checked between MDMP 46B and Unicode ECC6 with production client table SKAT. some Spanish display not correct.
    Unicode ECC6.0     46B
    Short Text     Short Text
    Ant a prov - Gto imp     Ant a prov - Gto imp
    Regal¨ªas     Regalías
    Prov Herramentales     Prov Herramentales
    Provisi¨®n de SLA     Provisión de SLA
    Prov Fin Vida (EOL)     Prov Fin Vida (EOL)
    Gtos de imp     Gtos de imp
    Mat dañado o perdido     Mat dańado o perdido
    Papeleria e insumos     Papeleria e insumos
    Gastos Vtas-Diseño     Gastos Vtas-Diseńo
    Ganancia p fluc camb     Ganancia p fluc camb
    Aj anual p inf     Aj anual p inf
    Depreciaci¨®n fiscal     Depreciación fiscal
    Best Regards
    Key

  • Unicode Attribute - Necessary before Unicode Conversion?

    We are about to upgrade to ECC 6.0 with a Unicode conversion.
    I know that the "Unicode Checks Active" flag must be set in every
    customer program in order for the code to run in an ECC 6.0 unicode environment.
    My question is does this HAVE to be done before we do the unicode
    conversion. What we would like to do is convert the system to ECC 6.0
    with Unicode and then apply the transports which set the "Unicode
    Checks Active" flag. Since some of these transports contain new
    objects, we would prefer to upgrade to ECC 6.0, then convert to unicode
    first and apply the transports afterwards, to reduce the risk of potentially needing to rerun
    scans.
    Ideally we would have cleared all this before the upgrade, but we only
    found this issue in our test system after we had upgraded it.
    Is this a bad plan?

    Hi Chris,
    it is not necessary to set the Unicode flag for programming objects in order to succeed with the technical Unicode conversion.
    However please keep in mind that the programs without flag will not work in the Unicode environment (as you already stated).
    Best regards,
    Nils Buerckel
    SAP AG

  • Could you pls give the details about the Unicode conversion during Upgrade

    Hi,
    Can anyone give details about the Unicode conversion during SAP Upgradation fro 4.6C to ECC6.
    Waiting for quick response
    Best Regards,
    Padhy

    Hi,
    These are the few points i gathered during my upgradation project.
    Before starting any upgradation project, it is necessary to take up the back-up of the existing systems. As we are going to upgrade the entire system, we will be changing so many things and if something happens, without back-up, we will be in a trouble.
    So it is advised to keep a back-up of the existing system.
    Say for example we have the existing system E4B which is of Version 4.6C. Now we want to upgrade it to Version 4.7. Let us see how we can do it.
    Version upgrades not only means that we need to run the new Version CD over the existing Version System but only involves some other thing.
    Version Upgrade involves the following Steps.
    Say we want to upgrade for Version 4.7 from Version 4.6, which is in the System E4B. Now we created one more system called as E1B in which the upgradation for Version 4.7 can be done.
    • First copy the entire E4B system into the E1B System which is created for Version 4.7.
    • Apply the Version 4.7 CD provided by SAP over the E1B System.
    • Now check whether all the functionalities that was in E4B system works fine with E1B system also.
    Thus the Version Upgrade involves two steps.
    1. SAP Upgradation with the help of the CD
    2. Manual Upgradation.
    1. SAP Upgradation with the help of the CD
    This is nothing but after taking the copy of the existing system into a new system, the upgradation CD from SAP is applied over the new system.
    2. Manual Upgradation.
    This Manual Upgradation involves
    2.1 Upgradation of Standard Objects
    2.1.1 SPAU Objects
    2.1.2 SPDD Objects
    2.2 Upgradation of Custom Objects.
    Upgradation of Custom Objects can be placed under the following three categories.
    Unicode Compliance
    Retrofit
    Upgrade
    Please Find below some of the common Unicode Errors and their solutions
    1. Error:
    In case of Translate Error; ‘Dangerous use of Translate in Multilingual system.’
    Correction:
    To correct the Error occurring on TRANSLATE statement – use this additional statement before the Translate statement.
    SET LOCALE LANGUAGE sy-langu.
    This statement defines the Text Environment of all the programs & internal sessions in the language specified in the LANGUAGE KEY, which in this case is “sy-langu”, i.e. the log on language of the user.
    2. Error:
    In case of Open Dataset Error; ‘Encoding Addition must be included.’
    Correction:
    This Error occurs only when the MODE is TEXT.
    To correct the Error occurring on OPEN DATASET statement – use this statement instead.
    OPEN DATASET dataset_name FOR access IN TEXT MODE ENCODING DEFAULT.
    Where: dataset_name – NAME OF THE DATASET.
    Access – INPUT or OUTPUT or APPENDING or UPDATE.
    DEFAULT - Corresponds to UTF-8 in UNICODE systems &
    NON_UNICODE in NON-UNICODE systems.
    3. Error:
    In case of the usage of the Obsolete FM UPLOAD/DOWNLOAD or WS_UPLOAD/DOWNLOAD; ‘Function module UPLOAD is flagged as obsolete.’
    Correction:
    The FM GUI_DOWNLOAD/UPLOAD is used.
    The variations to be made in the parameters of the FM:
    1. Filename – It must be of STRING type.
    2. Filetype – “DAT” is not used any longer, instead “ASC” is used.
    3. Field Separator – The default value “SPACE” is used, incase for a TAB separated file “X” can be used.
    4. Error:
    In case of CURRENCY/UNIT Addition Error; ‘Use addition CURRENCY/UNIT when outputting.’
    Correction:
    The CURRENCY addition specifies the currency-dependant decimal places for the output of the data objects of type i or p. To obtain the currency-key, the field CURRKEY of the table TCURX is used. The system determines the number of the decimal places from the field CURRDEC of the selected CURRKEY.
    To correct this error follow the following method:
    WRITE: /3 'TOTAL',' ', TOTAL.
    WRITE: /3 ‘TOTAL’,’ ‘, TOTAL CURRENCY ‘2’. --- Where ‘2’is the Currency Key for Getting 2 decimal places.
    5. Error:
    In case of TYPE X Error; ‘Variable must be of C, N, D, T or STRING type.’
    Correction:
    We need to change all the Type X (Hexadecimal) variables to Type C with their values unchanged.
    So the method to be followed is:-
    1. Load the definition of the class CL_ABAP_CONV_IN_CE or CL_ABAP_CHAR_UTILITIES.
    2. Declare the variable as Type C, and use the method UCCP(‘XXXX’) of the class CL_ABAP_CONV_IN_CE where XXXX represents the 8-bit Hexadecimal value and incase the variable holds a Hex value for a Horizontal Tab , then the Attribute “HORIZONTAL_TAB” of the class CL_ABAP_CHAR_UTILITIES can be used directly instead of using the method UCCP.
    E.g.:
    i) *DATA: TAB TYPE X VALUE 09, “Tab character
    CLASS: CL_ABAP_CHAR_UTILITIES DEFINITION LOAD.
    DATA TAB TYPE C VALUE CL_ABAP_CHAR_UTILITIES=>HORIZONTAL_TAB.
    ii) * DATA: CHAR TYPE X VALUE 160.
    CLASS: CL_ABAP_CONV_IN_CE DEFINITION LOAD.
    DATA CHAR TYPE C.
    CHAR = CL_ABAP_CONV_IN_CE=>UCCP(‘00AO’).
    (Here ‘00A0’ is the Hexadecimal equivalent of the decimal 160).
    3. Incase the TYPE X Variable has a length more than 1, then an internal table must be created for the variable.
    E.g.:
    CLASS: CL_ABAP_CONV_IN_CE DEFINITION LOAD.
    DATA : LF(2) TYPE X VALUE 'F5CD'.
    DATA : BEGIN OF LF,
    A1 TYPE C,
    A2 TYPE C,
    END OF LF.
    LF-A1 = CL_ABAP_CONV_IN_CE=>UCCP('00F5').
    LF-A2 = CL_ABAP_CONV_IN_CE=>UCCP('00CD').
    6. Error:
    In case of the Character “-“Error; ‘The Character “-“can’t appear in names in Unicode Programs.’
    Correction:
    The Character “-“(Hyphen) appearing in Variable names is replaced by the character “_” (Under Score) for Unicode/Upgrade Compliance.
    E.g.:
    *wk-belnr LIKE bkpf-belnr,
    *wk-xblnr LIKE bkpf-xblnr,
    *wk-date LIKE sy-datum,
    *wk-wrbtr LIKE bseg-wrbtr,
    *wk-name1 LIKE lfa1-name1,
    *wk-voucher(8) TYPE c.
    wk_belnr LIKE bkpf-belnr,
    wk_xblnr LIKE bkpf-xblnr,
    wk_date LIKE sy-datum,
    wk_wrbtr LIKE bseg-wrbtr,
    wk_name1 LIKE lfa1-name1,
    wk_voucher(8) TYPE c.
    7. Error:
    In case of The SUBMIT-TO-SAP-SPOOL Error; ‘you should not use the statement SUBMIT-TO-SAP-SPOOL without the WITHOUT SPOOL DYNPRO addition. ‘
    Correction:
    1. Declare variables of type PRI_PARAMS, ARC_PARAMS, and a variable of TYPE C which would be used as a VALID FLAG.
    2. Call the FM GET_PRINT_PARAMETERS:
    CALL FUNCTION 'GET_PRINT_PARAMETERS'
    EXPORTING
    ARCHIVE_MODE = '3'
    DESTINATION = P_DEST
    IMMEDIATELY = 'X'
    IMPORTING
    OUT_ARCHIVE_PARAMETERS = archive_parameters
    OUT_PARAMETERS = print_parameters
    VALID = valid_flag
    EXCEPTIONS
    INVALID_PRINT_PARAMS = 2
    OTHERS = 4
    3. Use the SUBMIT-TO-SAP-SPOOL statement.
    E.g.:
    •     submit zrppt500
    •     using selection-set 'AUTO3'
    •     with res_no eq lo_rsnum
    •     with sreserv in preserv
    •     to sap-spool destination p_dest
    •     immediately 'X'. "print immediate
    DATA: print_parameters type pri_params,
    archive_parameters type arc_params,
    valid_flag(1) type c.
    CALL FUNCTION 'GET_PRINT_PARAMETERS'
    EXPORTING
    ARCHIVE_MODE = '3'
    DESTINATION = P_DEST
    IMMEDIATELY = 'X'
    IMPORTING
    OUT_ARCHIVE_PARAMETERS = archive_parameters
    OUT_PARAMETERS = print_parameters
    VALID = valid_flag
    EXCEPTIONS
    INVALID_PRINT_PARAMS = 2
    OTHERS = 4
    Submit zrppt500
    Using selection-set 'AUTO3'
    With res_no eq lo_rsnum
    with sreserv in preserv
    to sap-spool
    SPOOL PARAMETERS PRINT_PARAMETERS
    ARCHIVE PARAMETERS ARCHIVE_PARAMETERS
    WITHOUT SPOOL DYNPRO.
    8. Error:
    In case of Message Error; ‘Number of WITH fields and number of Place Holders are not same ‘.
    Correction:
    Split the statement after WITH into the same number as the place holder for that Message ID.
    E.g.:
    1. * MESSAGE E045.
    MESSAGE E045 WITH '' ''.
    2. in program ZIPI0801
    •     Start of change for ECC6
    •     message e398(00) with 'Could not find access sequence'
    •     'for condition type:'
    •     p_ptype.
    message e398(00) with 'Could not find '
    'access sequence'
    'for condition type:'
    p_ptype.
    •     End of change made for ECC6
    9. Error:
    In case of Move between 2 different Structures; ‘The structures are not mutually convertible in a Unicode program.’
    Correction:
    Make both the Data Types compatible and then assign the contents.
    E.g.:
    The statement –“move retainage_text to temp_text.” Gives an error, where RETAINAGE_TEXT is an internal table and TEMP_TEXT is a string of length 200.
    A Feasible solution for this is to specify from which position to which position of the string, the fields of RETAINAGE_TEXT should be assigned.
    TEMP_TEXT+0(1) = RETAINAGE_TEXT-DQ1.
    TEMP_TEXT+1(1) = RETAINAGE_TEXT-HEX.
    TEMP_TEXT+2(20) = RETAINAGE_TEXT-FILLER1.
    TEMP_TEXT+22(15) = RETAINAGE_TEXT-AMT_DUE.
    TEMP_TEXT+37(8) = RETAINAGE_TEXT-TEXT.
    TEMP_TEXT+45(10) = RETAINAGE_TEXT-DUE_DATE.
    TEMP_TEXT+55(1) = RETAINAGE_TEXT-DQ2.
    10. Error:
    In case of ‘no description found’; ‘add a GUI title’.
    Correction:
    In this type of error gui title is generally missing so add a GUI title to the module pool.
    11. Error:
    In case of ‘writing internal or transparent table’
    Correction:
    Write individual fields.
    E.g.:
    WRITE: / EXT. --> EXT should be a character type field
    WRITE: / EXT-ZZSTATE, EXT-LINE_NO, EXT-LINE_TXT, EXT-AMT, EXT-ZZSKUQTY.
    12. Error:
    In case of ‘combination reference table/field S541-UMMENGE does not exist’
    Correction:
    Was due to error in reference table S541. TABLE S541 has errors
    1)”Foreign key S541- ZZMARKET (ZZMARKET AND KATR2 point to different domains)”
    2)”Foreign key S541-ZZACQUIGRP (ZZACQUIGRP AND KATR8 point to different domains)”
    Changed the domain of ZZMARKET (from ZMKCODE to ATTR2)
    And that of ZMKCODE (from ZACCODE to ATTR8)
    13. Error:
    In case of ‘KEY does not exist’
    Correction:
    The reference table for field KBETR was KNOV earlier changed it to RV61A as KNOV was in turn referring to RV61A.
    14. Error:
    Incase of ‘WRITE’ statement, ‘Literals that take more than one line is not permitted in Unicode systems.’
    Correction: To correct this error, we need to align the spaces accordingly so that the statement doesn’t go beyond the line.
    15. Error:
    Incase of Data statement, ‘The data type ZWFHTML can be enhanced in any way. After a structure enhancement, this assignment or parameter might be syntactically incorrect………..’
    Correction: To correct this error, instead of “like” in the Data statement, use “type”.
    16. Error:
    Incase of DESCRIBE statement, ‘DESCRIBE can be used only with IN BYTE... Or IN CHARACTER mode in Unicode systems.’
    Correction: To correct this error, use additional text, IN BYTE MODE / IN CHARACTER MODE along with this statement.
    CHARACTER MODE is added when the data object is of flat/ character type.
    BYTE MODE is added when the data object is a deep structure.
    Syntax: DESCRIBE FIELD data_obj : LENGTH blen IN BYTE MODE,
    LENGTH clen IN CHARACTER MODE.
    Where blen and clen must be of type I.
    17. Error:
    Incase of DO-LOOP Error,’ In Do loop range addition needed‘
    Correction:
    An internal tables is declared and the two fields (VARYING field and NEXT field) were
    Included inside the internal table
    E.g.: In program SAPMZP02
    DO 11 TIMES
    •     VARYING STATION_STATE FROM STATION1 NEXT STATION2. “ECC6
    CASE SYST-INDEX.
    WHEN ‘1’
    STATION_STATE = STATION1.
    WHEN ‘2’
    STATION_STATE = STATION2.
    WHEN ‘3’
    STATION_STATE = STATION3.
    WHEN ‘4’
    STATION_STATE = STATION4.
    WHEN ‘5’
    STATION_STATE = STATION5.
    WHEN ‘6’
    STATION_STATE = STATION6.
    WHEN ‘7’
    STATION_STATE = STATION7.
    WHEN ‘8’
    STATION_STATE = STATION8.
    WHEN ‘9’
    STATION_STATE = STATION9.
    WHEN ‘10’
    STATION_STATE = STATION10.
    WHEN ‘11’
    STATION_STATE = STATION11.
    18. Error:
    Incase of the parameter QUEUE-ID Error,’ QUEUE-ID’ is neither a parameter nor a select option in program rsbdcbtc.’
    Correction:
    The parameter in program rsbdcbtc is QUEUE_ID and so is changed in this program
    E.g.: In program Z_CARRIER_EDI_INTERFACE
    •     submit rsbdcbtc with queue-id = apqi-qid and return. "ECC6
    •     The parameter name changed by replacing '-' with '_' as in program rsbdcbtc "ECC6
    Submit rsbdcbtc with queue_id = apqi-qid and return. "ECC6
    19. Error:
    Incase of EPC Error,’ Field symbol <TOT_FLD> is not assigned to a field ‘.
    Correction:
    This error couldn't be rectified as the error occurs in a Standard SAP include- LSVIMF29.
    The OS Note - 1036943 needs to be applied.
    Error:
    OPEN DATASET P_FILE FOR OUTPUT IN TEXT MODE.
    Correct:
    OPEN DATASET P_FILE FOR OUTPUT IN TEXT MODE ENCODING DEFAULT.
    Error:
    Constants : c_tab type x value '09' .
    Correct:
    Constants : c_tab type abap_char1 value cl_abap_char_utilities=>horizontal_tab .
    Error:
    Data : begin of output_options occurs 0 . Include structure ssfcompop.
    Data : end of output_options .
    Correct:
    Data : output_options type standard table of ssfcompop with header line .
    Error:
    PARAMETERS : NAST TYPE NAST .
    Correct:
    PARAMETERS : NAST TYPE NAST NO-DISPLAY .
    Replace WS_DOWNLOAD and WS_UPLOAD by
    GUI_UPLOAD and GUI_DOWNLOAD and check the import and export parameter types , do the changes accordingly. Because FILENAME paramater type is different because of this it will give dump.
    For issue during Issue using SO_NEW_DOCUMENT_ATT_SEND_API1 Function module, the solution is After this FM we should put COMMIT WORK.
    Issue:
    Moving data from one structure to another structure if those two structures are not compatible
    Solution:
    we should use move-corresponding or field by filed we need to move it.
    If database structures are different in 4.6c and ECC6.0,
    Then we should go with append structure concept.
    While testing the report if it gives dump at Select query level or any database or view level,then just goto that table or view and goto the data base utility(se14) adjust the database. But make sure that selected radio button in se14 transaction should be activate and adjust database
    Also Check this link.
    http://help.sap.com/saphelp_nw04/helpdata/en/62/3f2cadb35311d5993800508b6b8b11/frameset.htm
    Reward points if helpful.
    Regards,
    Ramya

  • Support package requierement for unicode conversion

    We are currently planning a unicode conversion for a SAP 4.7enterprise 1.1 extension version, running under Aix and Oracle, Basis/ABAP SP 35, HR SP20.
    According to the conversion guide, we must implement at least Support Pachage 60 for Abap and Basis, no explicit requierement for HR SP level.
    I believed that we must applied SAP procedure and exclusively HR Support Package Stack up to 27, which include SP 60 for Basis and Abap and HR 61.
    Our HR guys argue there is no indication from SAP that the SUPPORT PACKAGE STACK policy is mandatory and that SAP will provide us with normal support if we run the unicode conversion with SP Basis/ABAP 60, in other word even if we do not respect the support package stack combinaison. Need help on this issue before starting the project

    Exterprise 4.7 is Unicode-Compliant,meaning that you can have unicode in 4.7.
    If that the case, you should convert to 4.7 Enterprise Ext 2.00 Unicode First.
    later only upgrade to ECC 6.0 after 2 years, as you said.
    My answer is yes, to your question.
    You can download the installation kits at:
    http://service.sap.com/swdc
    anyway, it is recommended to have the latest SP in your system.
    cheers,
    Vincent

  • Combined upgrade and Unicode conversion for ECC5 MDMP system

    Hello,
    We are planning to do Upgrade and Unicode conversion of ECC5 MDMP system to ECC6 EHP4 Unicode. We are adopting Combined upgrade and Unicode conversion strategy to minimise the downtime.
       In source version ECC5 we are in support pack level 6. Should we need to update the support pack to any target version to start with CU&UC or we can start with ECC5 with SP 6 itself.
    Since we cant afford more downtime for support pack update also, is it ok to start with upgrade and unicode conversion with current version.
    please advice.
    Regards
    Vinay

    Hello Vinay,
    please note that as a prerequisite the Basis SP should be accurate for an MDMP conversion.
    There is no MUST to have the latest Basis SP, but without you could have severe issues in SPUMG.
    On the application side, there are in most cases no hard requirements on the SP level.
    Best regards,
    Nils Buerckel
    SAP AG

  • Livecache changes during SCM Unicode conversion

    I am starting a unicode conversion of our SCM system which was just upgraded to 7.01. Before the conversion, our liveCache database was on a different host than our SCM system so we moved it to the same hardware. The process we used was to do a backup of the current liveCache, create a new instance on the new hardware and then do a restore of that liveCache  from the original liveCache's backup.
    For the Unicode conversion can we use this same process, but before restoring the liveCache, change the _UNICODE = 'YES' parameter for the liveCache? I read note 632357, but it didn't seem like that was neccessary, if I just created a new instance of liveCache where the SCM system target would land, changed the parameter and then did a restore from the backup?

    Hello George,
    1) The _UNICODE liveCache parameter should have the same value in the target liveCache instance as you have in the source liveCache instance, if you would like to do the
    u201CHomogenous liveCache copy using backup/restoreu2019 using the SAP note:
    457425    Homogenous liveCache copy using backup/restore
    2) If you are planning to convert your system/liveCache to Unicode you have to follow all steps given in the SAP Note No. 632357.
    3) If you have problems to follow the steps recommended in the SAP Note No. 632357, please create the SAP message to the component BC-DB-LCA, so we could discuss your issues in details.
    Thank you and best regards, Natalia Khlopina

  • Unicode conversion - ABAP.

    I am working in unicode conversion assignment. Please help me to resolve the issue.
    The data displayed in the report ( data from database it is displayed in english even though logon language is chinese ). Please tell me how to have those information in chinese ?
    With Thanks and Regards,
    Ganesh

    hi
    good
    go through this link, i hope this ll help you to solve your problem
    http://www30.sap.com/korea/Company/Events/techday05/img/data_01.pdf
    thanks
    mrutyun^

Maybe you are looking for

  • Powerbook audio in/out: advice needed

    I don't understand my 15" aluminum powerbook's audio in/out. I know that the input jack requires a far higher power signal than my nylon string Gibson solid body Chet Atkins CE guitar is able to generate, so I have to run the signal from my guitar th

  • MBP 15 is running and screen goes white with thin vert lines

    Running normally and if I adjust the screen angle it goes white with lines.  Just started happening.  10.5.8 about 4 years old

  • How do I remove yahoo "automatic" homepage?

    Just recently, when I open another "tab" within FF instead of going to the designated page I set up in tools: options: general, it goes to the regular yahoo search engine page (and takes longer than usual to do that). I have attempted removing all th

  • How can i transfer iphoto pictures from my ipad 1 to my new imac?

    My old mac had a hard drive failure so i cant transfer the pictures from my old computer. I keep having the issue of the ipad not being registered with that libary, and i cannot register the ipad to that libary without erasing everything.

  • SAP HR Project Charter...

    Guys, Does anybody have the Scope of SAP HR Implementation Project Charter, which is mapped by the implementation partner to the client. Help needed immediately. Ashish