Issue with share point 2007 website performance

Hi,
we have a sharepoint 2007 farm implemented in our organization. We have 2 web servers running over NLB, 1 application server and 2 SQL 2005 database servers in clustered mode. We are facing a strange issue from the past one week with the performance of the
website deployed from sharepoint. Iam mentioning it as starange because there was no change in any kind of configuration from the server lervel or from the application or databasde level. the performance of the server also seems perfectly alright the only
error i keep getting is event id 5010 "the application pool of sharepoint website has failed to respond to a ping" and then the application pool hangs and my website goes down. This issue is repeated atleast twice in an hour.
I would be very thankful if any one can please suggest me what has to be done in order to mitigate this issue.
Thanks in advance.

Hi,
There's a post in MSDN that helps you to understand what's happening:
http://blogs.msdn.com/b/pfedev/archive/2012/09/30/troubleshooting-event-id-5010-iis-application-pool-availability.aspx
Rodrigo A. Romano - SharePoint Server MVP - http://rodrigoromano.net

Similar Messages

  • I have an older version of Firefox 3.6.6 I believe I am having an issue with one of the websites I sign into. Is there any way to update to the newest version

    I have an older version of Firefox 3.6.6 I believe I am having an issue with one of the websites I sign into. Is there any way to update to the newest version. Without losing all my bookmarks and saved pass words?

    Hello johngervais, the latest firefox version is 26.0 (today 4 Jan 2014).
    note that [https://support.mozilla.org/en-US/kb/firefox-no-longer-works-some-versions-windows-xp Firefox no longer works with some versions of Windows XP], if you have '''xp with sp2 and above''' you can update to latest version, see : [http://www.mozilla.org/en-US/firefox/26.0/system-requirements/ Firefox 26 System Requirements]
    if you are able to update to latest version then see : [https://support.mozilla.org/en-US/kb/common-questions-after-upgrading-firefox-36 Common questions after upgrading from Firefox 3.6]
    see also : [https://support.mozilla.org/en-US/kb/firefox-just-updated-why-it-asking-me-update-again Firefox just updated - why is it asking me to update again?]
    Don't worry you won't losing bookmarks and passwords after update firefox.
    thank you

  • What is the best way to follow the scenario for Out look integration with share point using SAP Gateway?

    1)what is the best way to follow the scenario for Out look integration with share point using SAP Gateway?
    2)workflow concepts for Purchase order?
    3)Email triggering from out look for an approval process of PO? how these scenario can be best implemented with updated functions in Duet Enterprise.

    Hi,
    I do not have much idea on gateway integration with outlook but found out this document GWPAM Workflow Template which can be helpful for you to start with.
    also you may want to post your question in SAP Microsoft Interoperability forum
    Regards,
    Chandra

  • Ipod Shows File with Exclaimation Point and Website

    My ipod screen is black and white and has a website address(www.apple.com/support/ipod)and i cant go past that screen, ive tried reseting it, pluging it in, and charging it and it won't fix it. HELP!
    Dell Dimension 4550   Windows XP  

    See these.
    iPod shows a folder icon with exclamation point after disconnecting.
    iPod shows a folder icon with exclamation point when you turn it on.

  • Issue with OSPF Point-to-Multipoint over CES Cloud

    I'm having an issue running ospf point-to-multipoint over a CES cloud.  The reason I want to do this is that not every site has the same bandwidth and this way I can use neighbor statements to specify the cost to each neighbor.
    To make this work I have to shut down the cloud facing interface on each node and bring them up one at a time.  Everything runs fine until I then shut one of them down and bring it up again, I'm only able to form adjanceis with 2-3 nodes - the other nodes get stuck in either INIT or EXSTART until OSPF give up do to too many retires.  If I then repeat the process of shutting down the interface on each node and bringing them back up it works again.
    I've tried both " ip ospf network point-to-multipoint" and " ip ospf network point-to-multipoint non-broadcast" with the same results.
    Here are the router types involved and the firmware they are running:
    1. asr1006 asr1000rp1-adventerprisek9.03.10.00.S.153-3.S-ext.bin
    2. asr1006 asr1000rp1-adventerprisek9.03.10.00.S.153-3.S-ext.bin
    3. 2821 c2800nm-ipbasek9-mz.151-3.T4.bin
    4. 2821 c2800nm-ipbasek9-mz.151-3.T4.bin
    5. 2921 c2900-universalk9-mz.SPA.150-1.M1.bin (ipbasek9 license)
    6. 2921  c2900-universalk9-mz.SPA.153-2.T.bin (ipbasek9 license)
    7. 2821 c2800nm-ipbasek9-mz.151-3.T4.bin
    Here is the relevant config from one of the routers:
    interface GigabitEthernet1/0/6
     description CES
     bandwidth 50000
     ip address 10.226.126.30 255.255.255.224
     no ip redirects
     ip flow ingress
     ip flow egress
     ip ospf authentication message-digest
     ip ospf message-digest-key 1 md5 blahblahblah
     ip ospf network point-to-multipoint non-broadcast
     ip ospf dead-interval 3
     ip ospf hello-interval 1
     load-interval 30
    router ospf 1
    router-id 10.226.1.9
    ispf
    auto-cost reference-bandwidth 10000
    timers throttle spf 10 100 5000
    timers throttle lsa 10 100 5000
    timers lsa arrival 80
    passive-interface default  
    no passive-interface GigabitEthernet1/0/6
    network 10.226.126.0 0.0.0.31 area 0
    neighbor 10.226.126.6 cost 1000
    neighbor 10.226.126.5 cost 3333
    neighbor 10.226.126.4 cost 3333
    neighbor 10.226.126.3 cost 3333
    neighbor 10.226.126.2 cost 3333
    neighbor 10.226.126.1 cost 200
    All the routers have at least one other interface running OSPF point-topoint with no issues.  The ASRs also have some stub areas in addition to area 0.  I've tried taking the ASRs out of the loop and testing, but the results are the same.
    Please let me know if you have any ideas or need more details.
    Thanks.

    Hi Peter,
    believe me: I was perplexed as well and it took me some time to understand what was going on.
    I've created a simple gns3 lab (topology attached) with handy IP- and MAC addresses:
    R1: 192.168.0.1; 02:00:00:00:11:11
    R3: 192.168.0.3; 02:00:00:00:33:33
    R4: 192.168.0.4; 02:00:00:00:44:44
    The host routes for the point-to-multipoint interfaces play an important role:
    R3#show ip route 192.168.0.0
    C 192.168.0.0/24 is directly connected, FastEthernet1/0
    O 192.168.0.1/32 [110/1] via 192.168.0.1, 00:02:44, FastEthernet1/0
    O 192.168.0.4/32 [110/64] via 172.16.34.4, 00:02:44, Serial0/1
    Now, with a debug arp enabled on R1 we can see what happens when we shutdown and re-enable Fa1/0.
    R1(config-if)#do show ip int brief f1/0
    Interface IP-Address OK? Method Status Protocol
    FastEthernet1/0 192.168.0.1 YES NVRAM administratively down down
    R1(config-if)#do show ip arp
    <no output>
    R1(config-if)#no shut
    IP ARP: sent rep src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.1 ffff.ffff.ffff FastEthernet1/0
    IP ARP: sent rep src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.1 ffff.ffff.ffff FastEthernet1/0
    IP ARP: creating incomplete entry for IP address: 192.168.0.4 interface FastEthernet1/0
    IP ARP: sent req src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.4 0000.0000.0000 FastEthernet1/0
    IP ARP: creating incomplete entry for IP address: 192.168.0.3 interface FastEthernet1/0
    IP ARP: sent req src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.3 0000.0000.0000 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.4 0200.0000.4444, dst 192.168.0.1 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.3 0200.0000.4444, dst 192.168.0.1 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.4 0200.0000.3333, dst 192.168.0.1 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.3 0200.0000.3333, dst 192.168.0.1 FastEthernet1/0
    R1(config-if)#do show ip arp
    Protocol Address Age (min) Hardware Addr Type Interface
    Internet 192.168.0.1 - 0200.0000.1111 ARPA FastEthernet1/0
    Internet 192.168.0.3 0 0200.0000.3333 ARPA FastEthernet1/0
    Internet 192.168.0.4 0 0200.0000.3333 ARPA FastEthernet1/0
    R1(config-if)#do show ip ospf neighbor
    Neighbor ID Pri State Dead Time Address Interface
    4.4.4.4 0 INIT/ - 00:00:16 192.168.0.4 FastEthernet1/0
    3.3.3.3 0 FULL/ - 00:00:16 192.168.0.3 FastEthernet1/0
    OSPF: Rcv hello from 4.4.4.4 area 0 from FastEthernet1/0 192.168.0.4
    OSPF: Send immediate hello to nbr 4.4.4.4, src address 192.168.0.4, on FastEthernet1/0
    OSPF: Send hello to 192.168.0.4 area 0 on FastEthernet1/0 from 192.168.0.1
    OSPF: End of hello processing
    Because of the hostroute to R4, R3's proxy ARP answeres an ARP request for R4 (the same happens on R4)! At this point we have IP connectivity to R4 (via R3) but this doesn't work for OSPF's link local traffic.
    So just for the fun of it, we could configure a static ARP entry to verify if that will fix the problem:
    R1(config)#arp 192.168.0.4 0200.0000.4444 arpa
    %OSPF-5-ADJCHG: Process 1, Nbr 4.4.4.4 on FastEthernet1/0 from LOADING to FULL, Loading Done
    R1(config)#no arp 192.168.0.4 0200.0000.4444 arpa
    IP ARP: creating incomplete entry for IP address: 192.168.0.4 interface FastEthernet1/0
    IP ARP: sent req src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.4 0000.0000.0000 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.4 0200.0000.4444, dst 192.168.0.1 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.4 0200.0000.3333, dst 192.168.0.1 FastEthernet1/0
    Or we could avoid that R3 installs an OSPF hostroute to 192.168.0.4.
    R3(config)#ip prefix-list NO-HOSTROUTES deny 192.168.0.0/24 ge 32
    R3(config)#ip prefix-list NO-HOSTROUTES permit 0.0.0.0/0 le 32
    R3(config)#router ospf 1
    R3(config-router)#distribute-list prefix NO-HOSTROUTES in
    R3(config-router)#do show ip route 192.168.0.4
    Routing entry for 192.168.0.0/24
    Known via "connected", distance 0, metric 0 (connected, via interface)
    R1(config)#do clear ip arp 192.168.0.4
    IP ARP: sent req src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.4 0200.0000.3333 FastEthernet1/0
    IP ARP: creating incomplete entry for IP address: 192.168.0.4 interface FastEthernet1/0
    IP ARP: sent req src 192.168.0.1 0200.0000.1111,
    dst 192.168.0.4 0000.0000.0000 FastEthernet1/0
    IP ARP: rcvd rep src 192.168.0.4 0200.0000.4444, dst 192.168.0.1 FastEthernet1/0
    %OSPF-5-ADJCHG: Process 1, Nbr 4.4.4.4 on FastEthernet1/0 from LOADING to FULL, Loading Done
    An interesting detail is the destination MAC address in the first request. Seems like the MAC address of the former ARP entry was still cached somewhere.
    The adequate solution to solve the problem is of course disabling proxy-ARP.
    I was quite surprised to see that that the protocol logic obviously ignores the fact of being in the same subnet but rather simply check if there is another entry for the requested host in the routing table.
    The sanity checks section of RFC 1027 says
    "An ARP subnet gateway implementation must not reply if the physical networks of the source and target of an ARP request are the same."
    and it seems to me that IOS has not implemented this check. I'm looking forward to hear your opinion!
    Thanks for joining,
    best regards
    Rolf

  • Issues with a PowerPoint 2007 presentation in a Share POD

    Hello everybody.
    Today I held a CP8 presentation hosted at the following URL:
       https://connectpro825084440.preview.adobeconnect.com/robertozini
    While I was arranging things some days before the meeting, I noticed that a PPT 2007 presentation I "preloaded" into CP8 (in my CONTENT space) sometime got stuck when depicted on the share pod; all I had (both in meeting host/presenter/ pod) was the revolving "Adobe Presenter" logo but nothing was depicted on the pod.
    Please notice that, in the past few days, I made several changes in the PPT 2007 file; each time I wanted to test the file in a meeting session, I switched to the WEB admin console, selected Content -> User Content -> <my_name> -> <my_folder> -> <my_presentation> and clicked over the "Upload Content" as to "refresh" the content itself.
    During my tests, once in the meeting room , I selected a share pod -> Share Document -> My Content -> <my_folder> -> <my_presentation> ; when the issue was noticed (again, that did not always happen)  I had the revolving "Adobe Presenter" logo but nothing was depicted.
    Once this happened during my tests, I did exit and re-enter the meeting and shared the presentation again and this fixed this issue; today, during a presentation I gave to some customers. when I switched from a layout to the one which had the Share pod with my PPT file, one customer completely lost my presentation (grey screen) whereas the other one was able to see it fine.
    I had a WinXP+SP3 box here I use as a test box and, on this box, I was unable to see my PPT (again, the Adobe Presenter revolving logo). I tried by [Stop Sharing] the presentation and by reloading from content but unsuvvessfully (as a Host, I also had the revolving logo depicted).
    I was lucky since I was at the very end of the presentation but this behaviour was rather weird and embarassing...
    Please let me know if you want to access my PPT file (no presenter stuff inserted) as to reproduce the behaviour.
    Thanks,
    Roberto

    Hello!
    Can you enable the meeting add-in logs on your computer, and try the upload again? Once you have the add-in logs please attach them here.
    The steps to enable the add-in can be found here:
    http://kb2.adobe.com/cps/606/fd606fac.html
    Thanks!

  • Since downloading Firefox on a new Windows 8 PC I have issues with adds imbedded in websites and IE10 shutting down & not working properly.

    Downloaded Firefox since several websites we use are not yet fully compatible with IE10. Since downloading IE10 will register a problem as soon as opened, shut down, then reopen to same page. Also have adds embedded in websites like Facebook that were not there previously, as well as popups from Firefox (Deal Caddy???) that I can't figure out how to disable. Also noticed that the two-finger scrolling in Windows 8 (when using IE10) no longer works correctly. These issues only exist for one of two users on this computer. The user that did not install Firefox does not have the above issues.

    In order to uninstall a possibly unwanted extension, please do the following:
    #From the Firefox window click the Firefox button at the top left and select ''Add-ons'', or, if the Firefox button is not shown, click the ''Tools'' menu and click ''Add-ons''.
    #Once the Add-on Manager has opened in a new tab, click the ''Extensions'' button on the left side of the window.
    #You should now see a list of your installed extensions on the right side together with buttons on the right side of each extension.
    #To remove an extension from Firefox, simply click the ''Remove'' button. You should see a message that informs you about the successful removal of the add-on.
    #Note that some add-ons require a Firefox restart to be removed completely. To perform a Firefox restart after the add-on removal, click the ''Restart now'' link in the message.
    You can find further information about uninstalling extensions in the following articles:
    [[Disable or remove Add-ons]]
    [[Remove a toolbar that has taken over your Firefox search or home page]]

  • Issue with fixed point number output from 9219 module for full bridge measurement (cRIO/FPGA)

    Hi,
    I have a question regarding the fixed point output acquired from a 9219 module (in FPGA on a cRIO) when setup to acquire a strain measurement (full bridge).
    Software: Labview 2009
    Hardware: cRIO-9012 (NI-RIO 3.2.1), NI-9219 module
    The 9219 module is configured in the project as follow:
    Ch0: Full-Bridge +/- 7.8mV/V
    Ch1: Voltage +/- 4V
    Ch2: Voltage +/- 15V
    Ch3: Voltage +/- 60V
    The calibration mode is 'Calibrated' so the FPGA outputs fixed point numbers. 
    My issue is that the precision of the fixed point number for Ch0 (strain) is "(fixed point <+/-32,-1>[-2.5e1,2.5e1]:1.16e-10)", which indicates that the fixed point number is a value between +/- 0.25 and not the +7.8mV/V as I expected?
    The fixed point number does not change in precision whether the range for the strain measurement is set at +/- 7.8mV/V or +/-64mV/V (the two available options).
    As the fixed point number doesn't change precision I'm assuming that changing the range of the strain measurement changes the resolution of the acquired number? And as such I will need to perform additional scaling on the fixed point number to convert it to the expected range?
    There is no mention of scaling of the voltage or strain measurements mentioned in any documentation or examples, with the only scaling example provided for the thermocouple measurements.
    Any help/clarification is much appreciated.
    Regards,
    Mike

    Hello Mike,
    Hopefully I can help clarify some of the behavior you are seeing.
    My issue is that the precision of the fixed point number for Ch0 (strain) is "(fixed point <+/-32,-1>[-2.5e1,2.5e1]:1.16e-10)", which indicates that the fixed point number is a value between +/- 0.25 and not the +7.8mV/V as I expected?
    For calibrated values on the FPGA VI, the returned data is a Voltage measurement, not a directly calculated strain value. Based on the specified ranges for the 9219 in a Full bridge configuration, 250 mV will encompass all possible input values, at the module provided excitation (2-2.7V dependent on the sensor gage resistance).
    The fixed point number does not change in precision whether the range for the strain measurement is set at +/- 7.8mV/V or +/-64mV/V (the two available options).
    As you may notice from the fix-point definition, the fixed point data contains 32-bit precision which is larger than the acquired precision of 24-bits provided by the 9219. The fixed point data-type is coded to accept input encompassing both the range and precision of the instrument; such that, no additional coercion of the input data values is required based on user-defined software settings, i.e. the bridge sensitivities +/- 7.8mV/V or +/-64mV/V. 
    As the fixed point number doesn't change precision I'm assuming that changing the range of the strain measurement changes the resolution of the acquired number? And as such I will need to perform additional scaling on the fixed point number to convert it to the expected range?
    The documentation does not clearly define that by varying the discrete levels of strain input (+/- 7.8mV/V or +/-64mV/V) the range of the ADC on the module is also adjusted. I am working to follow up further on this topic, to provide a clarification on the module documentation. As for scaling, the voltage values acquired regardless of the ADC resolution will still be related strain via the bridge sensitivity. The resolution of the ADC will simply define the smallest measurable change in the strain value. 
    There is no mention of scaling of the voltage or strain measurements mentioned in any documentation or examples, with the only scaling example provided for the thermocouple measurements.
    For converting the acquired voltage values to a strain measurement, I would recommend the documentation linked here for a detailed explanation on strain calculation. Often, users will forward the acquired voltage data as fixed point values through a DMA FIFO to the RT controller on the Compact RIO; such that, they may handle conversion from voltage to strain using floating point math in real-time. 
    I hopes these responses provided a bit of clarity. I will continue to work to provide additional information on the 9219 specification information. Please post back any further questions.
    Cheers!
     Edit: Forgot to add the link.
    Message Edited by Pcorcs on 04-14-2010 04:55 PM
    Patrick Corcoran
    Application Engineering Specialist | Control
    National Instruments

  • Issue with connecting to 1 website

    Hi there
    I hope someone can help me resolve this issue
    I'm having issues connecting to a website ( www.soccermanager.com ) via BT. It worked fine 2 days ago but not worked since. I can connect to it from my work pc, my iphone ( three 3g ) and my work blackberry ( vodafone ), but if I turn on wifi on either my iphone or blackberry and use my bt network it doesn't work. Site is definitely up but not working on my BT connection. I have also tried my work laptop via my home BT and it doesn't work either, so hopefully also ruling out a PC related issue.
    I can ping the server and get the same ip address as I do at work, so isn't a DNS issue ( even though I have also tried OpenDNS just in case ). When I run a tracert on it eventually times out at the 17th hop, the last hop before timeout was:
    16   129 ms   129 ms   129 ms  xe-0-1-0.er1.dfw2.us.above.net [64.125.27.74]
    Any ideas or suggestions of what's wrong ?
    Thanks for any help/suggestions, even if only to test the site and tell me it works for you or not.

    Reported via a live chat.  I must say that the guy was very helpful and said he'd reported the issue together with the tracert data I had provided.
    Afraid I lose the will when trying to speak to BT by phone!

  • Multiple issues with iCloud & Outlook 2007

    Hi all,
    I have a Windows 7 laptop with Outlook 2007 connected to Exchange. I've used the iCloud configuration panel (version 2.1.1) to set up synchronization of mail, contacts, calendars and tasks with Outlook. I can see the content of each iCloud component in Outlook, however:
    Outlook freezes completely when switching to the calendars. I have two personal calendars in iCloud and one shared calendar, and when I switch to the calendar view in Outlook it takes an average of 9 minutes and 45 seconds before Outlook is responsive again. And it's not just the first time after I've set up the sync. It's also not just every time Outlook is started. It's E-VE-RY time I switch to the calendar view! This behavior only occurs for the calendar, not for mail, contacts and tasks.
    I can add items such as contacts or appointments in the appropriate iCloud section in Outlook, but then it just sits there. It's not uploaded to iCloud. Not even when you press Refresh iCloud.
    Does anyone know how to solve this? I could live with the second issue, but the first issue is infuriatingly unacceptable...
    Kind regards,
    Maurits

    By anychance did you or your wife use any forwarding options under mobile me.

  • Palm Z22 and issue with using Outlook 2007.

    Info:  Palm Z22, Desktop software for Palm is updated to most current, Outlook 2007, 32 bit Windows Vista computer.
    I have been using Palm Z22 for several years.  I want to use Outlook 2007  but cannot get the data from the Palm device or the Palm desktop software transfered to the Outlook 2007.  I have tried a reinstall of the Palm Destop software, including choosing the Outlook option over the Palm option and nothing happens.
    My goal is to use Outlook 2007 to sync with the Palm Z22 device and vice versa.  I am wanting  the calendar primarily.
    Thankyou for any help. 
    Post relates to: Palm Z22
    This question was solved.
    View Solution.

    You need the Outlook 2007 conduits.
    Click here for the download page;
    http://kb.palm.com/wps/portal/kb/common/article/8716_en.html
    For reference purposes, click on the following link for the support page for your device on the kb.palm.com webpage.
    http://kb.palm.com/wps/portal/kb/na/zire/z22/unlocked/home/page_en.html
    There are links on the page to the user guide, troubleshooting, how to's, downloads, etc.

  • Issue with 3-point smoothing

    HI,
    I am trying to reduce my baseline noise with a 3-point smoothing filter. Attached are my printscreen result and my vi. I found that the 3-point smoothing did not have a significant effect to smooth the baseline. 
    I wonder if I programmed it wrong or the idea of 3-point smoothing is not a ideal way to reduce the background noise. In my case, it's ~0.7+/-0.2.  
    Please comment, 
    Michael
    Attachments:
    PrintScreen.JPG ‏174 KB
    VoltageMeterVIANIUSB6210v6CurveSmoothing.vi ‏172 KB

    Hi Lynn,
    The source of the signal is from a laser but I put ND filters to lower the intensity. The rate is 100Hz and the # of sample is 10 in continue mode. It happens that I have an old NI card (NI4050) in the lab. I tried with its old vi and suprisingly, it showed no noise. Result attached. 
    Now I want to try out this really old VI with the new NI-USB-6210. But I don't know the proper device # for NI6210. I was able to find the device # for NI4050 in "Measurement and automation explorer" but not 6210 (printscreen attached).
    Attached is the old vi.
    Please help to modify it so that it is usable for USB6210.
    Thanks in advance,
    Michael
    Attachments:
    NI4050 no noise.jpg ‏207 KB
    DeviceNo.JPG ‏84 KB
    PMT meter Ni6210.vi ‏52 KB

  • Having issues with flash player on website

    Hi i need some urgent help, my website www.travellynx.co.uk runs fine on firefox and chrome however on IE you can not get a quote
    ive had a look at the script and it seems there is a problem with google maps and flash player,
    any help would be great ive looked online and just dont know what to do about it
    thanks

    http://support.microsoft.com/kb/318378

  • Issues with Signing into a website on Firefox

    When trying to sign into some websites, Example http://syn-gaming.us, I log in correctly then the next page I go to I am instantly logged out.
    Help please!

    Cookies were the problem! Thanks

  • Load Dropdownlist with share point groups in Edit Form of workflow List

    Hi ,
      I have created a created a workflow for template approval process  when i edit the workflow task ,i would need to show 
    two drop down list 
    Memeber Group :Load sharepoint groups
    Assigned to :Display members from selected group.
    Could you tell  me how to implement this.
    Regards,
    .Net User

    Hi .Net User,
    Based on your description, do you mean that you want to show two drop down lists in the workflow tasks list’s edit form?
    And, do you want to display all the SharePoint Groups and all the members in the specific SharePoint Group that you select from the Group drop down list?
    Per my knowledge, we can add two new Task Form Fields to display the “Assigned To” column’s value of the current task, and the Approval Task Process’s Participant Groups, however, we cannot get all the SharePoint Groups in the workflow tasks list’s edit
    form using SharePoint Designer 2010.
    To implement it, please follow the steps as below.
    Click on the “Approval” of the action in the workflow, add two new Task Form Fields named “Assigned To Member”, “Member Group” with “Single line of text” type.
    Click on “Change the behavior of a single task” in the “Customization”, add two “Set Task Field” actions in “Before a Task is Assigned” section as below:
          Set Task Field ““Assigned To Member” to “Current Task: Assigned To” with “Display Name”, Set Task Field “Member Group” to “Task Process: Participant List” with “Display Names, Semicolon Delimited”.
      3.  Publish the workflow and test if it works in your environment.
    Then, the result is shown as below:
    Best Regards,
    Yumi Fu