Issues in Screen Painter

Hi All,
   The Screen painter (SE51) is not displaying with Graphical Layout editor,though i have selected the Graphical Layout editor check box (From Utilities->Screen Painter> set the Graphical Layout Editor check box also marked ) .
   Though i am not able to get Graphical layout editor instead i am getting the alphanumeric editor only.
  Can anyone please suggest or give a solution for this will be appreciable.

In case if u r not getting the Graphical Painter after installing the GUI Patch.
Contact you basis person and ask him to open a port suppying information to GUI at front end. It needs to be done at SERVER end.
Check the RFC - EU_SCRP_WN32 destination in SM59.
Perform a "Test Connection": if the connection doesn't work maybe there is an issue in the connection between the presentation server and the application server.
Check if there is a firewall that blocks the port used by the RFC.
I have the same problem if I use a VPN connection to logon. The graphical screen-painter does not work...
Hope this will give you some help in resolving the issue.
If it still persists pl. write back to me.
Darshan
<i><b>**Pl. reward points and close the thread if your problem gets resolved.</b></i>

Similar Messages

  • Issue with Screen Painter Add-On after patch updation

    Hi Experts,
    We are using 2007 B PL10. We upgraded to PL 11 and now we are getting the following error while trying to start the Screen Painter Add-On.
    "Wrong Executable digital signature for Add-on"
    Please help!
    Thanks in advance
    Ajith G

    Hi Ajith,
    Check the thread
    Installing addons on client
    Regards
    Jambulingam.P

  • Issue WIth Screen Painter

    I am trying to assign same varible to Field and corresponding text filed. But it is not allowing as it same duplicate field . All though I have done that for couple of screen elements. Please share your thoughts.

    Hi,
    You can assign the same name for a text field and an input/output field, it doesnt give any error.
    But you cannot assign the same name for 2 text fields or 2 i/o fields.
    Thanks,
    Sri.

  • Screen Painter :: GUI Issue

    Hi All,
    I'm not able to get the grahical screen painter but this message,
    EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'.
    I had searched and there were info about sap logon details.
    Version 7.10 Compilation 2
    Pls. suggest some solution.
    Thank you.

    Hi,
    There had been a connectivity issue on RFC EU_SCRP_WN32 and hence the issue.
    Thank you.

  • Screen Painter and RFC connection issue

    Hello,
    I get the following error when I try to start screen painter:
    EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'
    I have installed all sapgui components and when I test the rfc connection it
    starts the program but then sends the same error.
    I think it's got something to do with the fact that I'm trying to start this
    program through a saprouter because when I start it locally (within my LAN)
    the program starts without problems.
    I have already applied latest kernel patch.
    Could you suggest what could I do to complete my RFC connection? Should I
    put something under gateway host or gateway service?
    Thanks in advance

    The issue here is that I don't know how to establish de gateway option
    considering I'm using saprouter to connect to sap system.
    Well... If you are asking how to "enable" gateway option then...
    You go to SM59 > Open EU_SCRP_WN32 > Go to "Technical Setting" tab
    Click on change option.
    Put the Gateway host IP address or Host name (SAP Server)  > Save
    Check the connection by "Connection Test" option.
    If any error... pls post here.

  • Error while opening a screen painter

    Hi all,
    I am trying to modify a screen in SE80. But when i am clicking on the screen painter it shows 'EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'
    Message no. 37033. Please let me know how to resolve this issue. Thanks a lot for your help!
    Regards,
    Priti

    For the Future Problem Facers:
    I too faced the same problem and the below steps helped me.
    Re: SFLIGHT is NOT defined for the current logical database.
    You can check the completeness of the program installation by starting the program gneux.exe locally in the SAPGUI directory (for example, by double-clicking on the program name in the Explorer window).The Layout Editor is displayed with German texts and an empty drawing area for the pseudo screen EUSPDYND 0000.
    If the installation is not complete, an error dialog box provides information regarding the cause of the error, for example, sometimes the DLL eumfcdll.dll is missing after reinstalling the SAPGUI. For example, the eumfcdll.dll DLL was sometimes missing after the SAPGUI was reinstalled.

  • How to read the contents of Input Field created via Screen Painter?

    Hi All,
    I have a module program / dialog program, on my second screen, I created an input/outbox field via screen painter of course,
    now in my PAI, how can I read the contents of the input/outbox field?
    Let's say the name of my input/outbox field is: P_WEKRS.  Note: Get Parameter and Set Parameter is ticked.
    PROCESS AFTER INPUT.
      LOOP WITH CONTROL TC_DATA.
        MODULE MODIFY_DATA.
      ENDLOOP.
    I want to get the value of the input/outbox field before my loop in table control?  I thought that it will work like normal parameter in non-dialog programs.
    Any helpful inputs will be appreciated/rewarded.
    Thanks.
    Jaime

    Hi, Jaime
    Do the following Change in you Follow Logic
    PROCESS AFTER INPUT.
    MODULE read_or_change_value. " Add this
    LOOP WITH CONTROL TC_DATA.
      MODULE MODIFY_DATA.
    ENDLOOP.
    Add the Bellow Module code in you Driver Program.
    MODULE read_or_change_value.
    DATA: P_WEKRS like " the Field on Screen. Must be the same name as on SCREEN. and Type must be same too.
    " Here you will find the Value in that Variable or if you will change the Value here you will find it change on Screen
    END MODULE.
    Please Reply if any Issue..
    Best Regards,
    Faisal

  • SCreen Painter working not correctly.

    Hi,
    In se53 when we go to screen painter it's not coming properly..
    some line is coming.
    and we got EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'  error message.
    we have sap gui 710 with patch level 7.
    the dumpfile also generated.
    Runtime Errors         STORAGE_PARAMETERS_WRONG_SET
    Date and Time          22.07.2008 12:44:27
    Short text
    The system is configured incorrectly.
    What happened?
    The current program had to be terminated because of an
    error when installing the R/3 System.
    The program had already requested 453411792 bytes from the operating
    system with 'malloc' when the operating system reported after a
    further memory request that there was no more memory space
    available.
    What can you do?
    Note which actions and input led to the error.
    For further help in handling the problem, contact your SAP administrator
    You can use the ABAP dump analysis transaction ST22 to view and manage
    termination messages, in particular for long term reference.
    In the system profile, set the parameters
    -abap/heap_area_dia and
    -abap/heap_area_nondia
    to a maximum of 453411792. To be on the safe side, reduce the value by 10,000,
    000.
    Then restart the SAP system.
    Error analysis
    When the program was running, it was established that more
    memory was needed than the operating system is able safely
    to provide. To avoid a system crash, you must prevent this
    situation from occurring.
    Last error logged in SAP kernel
    Component............ "EM"
    Place................ "SAP-Server mtw02sdec01_DE7_00 on host mtw02sdec01 (wp
    1)"
    Version.............. 37
    Error code........... 7
    Error text........... "Warning: EM-Memory exhausted: Workprocess gets PRIV "
    Description.......... " "
    System call.......... " "
    Module............... "emxx.c"
    Line................. 1881
    The error reported by the operating system is:
    Error number..... " "
    Error text....... " "
    How to correct the error
    Report the error to the group responsible for installing your
    R/3 System.
    Please help.
    regards
    deepak

    Dump is telling you what to do...
    Review abap/heap_area_dia and abap/heap_area_nondia
    I presume you try that before posting right?...
    Whats the issue then?
    Regards
    Juan

  • [Help]Screen Painter

    Hi experts,
    Lately I'm using PL07 and now I uninstalled my SAP Client and installed PL04 after that, I'm having a problem with Screen Painter. Please check the image below. Help me about this.
    http://www.webforone.com/images/5dwd2lodq9rsjs3aiaf.jpg
    Thanks,

    hi hikaru,
    Symptom
    Add-on fails to upgrade on the client when there is a new add-on version available on the server in the common DB.
    SAP Business One displays an error message:
    "Add-on <Name of add-on>: Add-on installation failed because another version is already installed. Please ensure that the version number is higher than the version previously installed."
    Add-on status is then set to pending.
    Cause
    Consulting.
    This issue occurs when both of the following conditions are met:
    There is a version of the add-on available on the server in the SARI table of the common DB that is newer than the one on the client.
    The server name or IP address registered in the AddOnsLocalRegistration.sbo file on the client for this add-on is different than the name or IP address registered with the license server for the SAP Business One database server.
    For example, this issue can occur after upgrading to SAP Business One 8.8 and "(local)" is listed as the server name in the AddOnsLocalRegistration.sbo file. But according to new security policies, "(local)" is no longer a valid server name and the server name registered with the license server will have changed when upgrading to release 8.8.
    The following would occur in such a case:
    The SAP Business One 2007 client connects to the (local) server.
    The client registers an add-on from the server.
    The server is upgraded to release 8.8, and is registered with the license server with an IP address or server name. The client upgrades to release 8.8, and continues to work with the same server. The local AddOnsLocalRegistration.sbo file is unchanged by the upgrade.
    The add-on is upgraded on the server.
    At the next logon, the client checks the version of the add-on on the server and finds that it has been upgraded. The client attempts to upgrade the add-on using the information in the  AddOnsLocalRegistration file. But the upgrade fails because the server name in the file is incorrect.
    Solution
    (1) Open "AddOnsLocalRegistration.sbo" file
    (2) Locate the "Common" node under the "AddOn" node and update the          "Name" Attribute to the DB Server machine name which is currently       used.
    (3) Repeat step(2) to update the "Name" Attribute for all AddOns.
    (4) Lanuch the SAP Business One and AddOn should upgrade as usual.
    Other terms
    SAP Business One client, AddOnsLocalRegistration.sbo, add-on upgrade, 8.8 add-on upgrade fails
    regards,
    Fidel

  • Help!! graphical screen  painter can't use.

    hi,everyone.
    we conncet to sap with sapgui by saprouter.
    the graphical screen painter not available .
    how to deal with this problem?

    Check the RFC - EU_SCRP_WN32 destination in SM59.
    Perform a "Test Connection": if the connection doesn't work maybe there is an issue in the connection between the presentation server and the application server.
    Check if there is a firewall that blocks the port used by the RFC.
    I have the same problem if I use a VPN connection to logon. The graphical screen-painter does not work...
    Hope this helps,
    Roby.
    PS: check out if in <sapgui_directory>\FrontEnd\SapGui there are these executables:
    gnetx.exe and gneux.exe
    These are the necessary files to start the Screen-Painter.

  • Having Problems with my Screen Painter

    Hi,
    I'm new to SAP and I'm still learning. I'm on this part of tutorial wherein I am trying to create a Screen using the Screen Painter. But the problem is, the interface of SAP in the book looks something like this:
    http://www.kodyaz.com/articles/sap-abap-tutorial-alv-grid-cl_gui_alv_grid-screen-painter.aspx
    But my interface looks different. I'm sorry I can't post the picture here but It can be well described. It looks like a "notepad" with horizontal lines.
    Has anyone encountered this kind of screen painter? Hope someone could help me.
    Thanks.

    Hi,
    Do you receive some error like 'Graphical Layout Editor not available 37527'. Does the problem occurs only for some users or for all the users?
    If the issue is for all users, I suggest to check notes 101971 and 204910.                                                                               
    If its for a particular user, please make sure "graphical layout editor" is checked under SE51->munu Utilities/settings->tab ScreenPainter.           
    Hope this info helps,
    Br,
    Javier

  • Problem in opening of screen painter layout

    When I am opening screen painter using SE51 it opens,but layout should not be opened in a desired format.

    ... also the settings should be graphical screen painter.
    If this is not the issue, please explain what you mean by layout should not be opened in a desired format.. Shoud not? Is not? Whats the desire?
    Regards,
    Clemens

  • Update column in screen painter

    i have column in screen painter and i write data when i make enter it's dissapear why???

    Did you have corresponding data object defined in program?
    I guess this is where the issue comes from. Simply system can't exchange data b/w screen and program.
    Try declaring one, it should help then.
    Also, what do you mean by column ? If it is a table control you need to use definition of this table, the simplest is usually by
    TABLES name_of_table.
    If this is a single field taken as reference from DDIC you should simply define it like
    DATA name_of_table-name_of_column TYPE name_of_table-name_of_column.
    Regards
    Marcin

  • Screen Painter - Matrix CellHeight & TitleHeight

    Hi,
    In Screen Painter the Matrix CellHeight & TitleHeight change all the time when I open the Form in Screen Painter. It works when I run the Form, but when I change the Form I always have to change the CellHeight & TitleHeight before I close the fom...puh
    Any suggestion?
    Thank you,
    Rune

    Hai Rune,
              U r change the .srf file to .xml na. So i can able to modify the xml file. I also have the same issue. But i change in xml so its working fine.
    Here is the code
    <item uid="m_Dbond" type="127" left="15" tab_order="0" width="526" top="78" height="228" visible="1" enabled="1" from_pane="0" to_pane="0" disp_desc="0" right_just="0" description="" linkto="" forecolor="-1" backcolor="0" text_style="0" font_size="-1" supp_zeros="0" AffectsFormMode="1">
                  <AutoManagedAttribute />
                   <specific SelectionMode="0" layout="0" titleHeight="21" cellHeight="17">
                     <columns>
                       <action type="add">
                         <column uid="v" type="16" title="#" description="" visible="1" AffectsFormMode="1" width="20" disp_desc="0" editable="1" right_just="0" val_on="Y" val_off="N" backcolor="-1" forecolor="-1" text_style="0" font_size="-1">
                          <databind databound="1" table="@DBOND_DETAIL" alias="LineId" />
                          <ExtendedObject />
                        </column>
    Regards,
    Anitha

  • F4 Search Help on a screen painter

    Hi gurus,
    I am new to ABAP programming but i am getting there, thanks to all of you guys, i need help on this issue:
    1. How to enable or program search help on a certain field in a screen painter?
    Your help is much appreciated.
    Ramorua
    Edited by: Ramorua Modisha on Apr 29, 2008 1:36 PM

    Hi,
    There are couple of ways in which you can get a search help.
    1) To have a DD reference to the field
    for this create a search help in SE11 assign the same to the data element and have a reference.
    2) To write a Process on Value Request. in the Flow logic in SE51.
    In this even create a module and call the FM
    F4IF_INT_TABLE_VALUE_REQUEST to get the search help.
    Hope this helps
    Santhosh