Issues with Small Business Switch config

Hi, I know that if I read the documentation I will come to the answers but I would really like some input from someone with more knowledge than me. I have an issue with Cisco SF300 , one of the Small Business Switches. I have a single interface on my router and I need to separate my internal networks , I thought that one way would be to use VLANs. On my two internal networks one network only has unmanaged D-Link switches, the other has the Cisco SF300 so I did as follows. 
On the Cisco Switch, all ports default to Trunk ports. I have changed FE1-FE24 and GE1-2 to access ports.
Created two VLANS and placed FE1-FE24 in VLAN10 (also my management VLAN) , GE3 is a trunk Port for VLAN20 untagged, VLAN 20 uplinks to my DiLink Switches. This way traffic from my unmanaged switches comes in on a trunk port untagged on VLAN20.
GE4 is a trunk port and I have assigned  VLAN1 untagged, VLAN10 tagged and VLAN20 tagged. VLAN 10 and VLAN 20 then forward to my Router.
The plan was to connect GE4 to my router however I had two things happen I can not explain.
Firstly as soon as I connected my D-Link to GE3 the LAN on VLAN20 went down, I could not ping Servers from PCs etc, all devices are connected to the unmanaged D-Links. Secondly the VLAN Assigment changed on GE3 and GE4 , VLANs 10 and 20 disappeared and only the default VLAN was assigned, also under VLAN Settings my VLAN interface state for VLAN20 shows Disabled. Also one of my access ports FE12 keeps changing VLAN.
Can anyone offer any suggestions as to what might have crashed the LAN and why my VLANs change. I did write my running config to the start up config by the way.
I added two screen shots. 
I would seriously appreciate some help.
Thanks 
Bob

Hi Garrett, thanks for your reply to my post, I hope you are well. I called Cisco support, they told me that they could not understand why this was happening and suggested a firmware upgrade, usually something I should have considered right from the beginning. This solved the issue for me.
Thanks
Bob

Similar Messages

  • SG200 Small business switch - vlan issue

    I have the wonderous task of remotely configuring a few SG200 small business switches.
    I need to create a vlan and move a few ports into that vlan, doesn't sound too difficult.
    I have created the vlans but when I go to add the ports into the vlan the only option I seem to have is General?
    If I specify access I can't say what vlan the port should be in?
    What am I doing wrong?
    All ports are currently in VLAN 1 and are in mode trunk
    I have created 2 new vlans and just want to put 4 ports in VLAN 2 and 4 ports in VLAN 4
    Can anyone impart any wisdom?
    Thanks
    Roger

    Hi Roger,
    Did you try this guide?
    http://sbkb.cisco.com/CiscoSB/Loginr.aspx?login=1&pid=2&app=search&vw=1&articleid=80
    Are you configuring it from GUI or CLI ?
    Regards
    Mariusz

  • JDev 10.1.3.3 - issues with imported Business Components

    Hi,
    I have got some issues with importing Business Components in JDev 10.1.3.3.
    I cannot discover/use the imported components.
    What I did is the folowing:
    1. In a existing project I extended the default base-classes to create our own layer
    2. created a project called ModelShared
    2a. configured the project to use the base-classes I created in step 1
    2b. created an entitybased-viewobject (RefCodesByDomain)
    2c. created bc deployment-descriptors
    3. created a project called RelatieModel in the same workspace as ModelShared
    3a. added dependencies to the deployment-descriptors as well as the project created in step 2
    3b. configured the project to use the base-classes I created in step 1
    3c. imported business components
    Although I did not recieve any errors during the import of business components, I am unable to add the vo (RefCodesByDomain) to a service.
    I do see the package which contains the vo but is has no entries.
    Importing the business components to a new BC Project in a seperate workspace did succeed (I could reuse the vo).
    I tested a little further and the folowing occurred:
    4. I created a new vo in the ModelShared Project
    5. I deployed the ModelShared
    6. Restarted JDeveloper
    7. Got the folowing error message in the console window when expanding a service in my datacontrol pallette:
    INFO: oracle.adf.share.config.ADFConfigFactory No META-INF/adf-config.xml found
    1-sep-2008 13:23:27 oracle.adf.dt.controls.DataControlsTreeWillExpandListener treeWillExpand
    FINER: THROW
    java.lang.NullPointerException
            at oracle.adf.dt.objects.JUDTViewReferenceAccessorDefinition.init(JUDTViewReferenceAccessorDefinition.java:108)
            at oracle.adf.dt.objects.JUDTViewReferenceAccessorDefinition.<init>(JUDTViewReferenceAccessorDefinition.java:98)
            at oracle.adfdt.internal.meta.bc4j.BC4JDataControlDefinition.createViewObjectDefinition(BC4JDataControlDefinition.java:228)
            at oracle.adfdt.internal.meta.bc4j.BC4JDataControlDefinition.addViewObjects(BC4JDataControlDefinition.java:208)
            at oracle.adfdt.internal.meta.bc4j.BC4JDataControlDefinition.loadStructure(BC4JDataControlDefinition.java:110)
            at oracle.adfdt.internal.meta.bc4j.BC4JDataControlDefinition.getStructure(BC4JDataControlDefinition.java:407)
            at oracle.adf.dt.controls.treemodel.jsr227.JSR227DataControlTreeNode.loadChildNodes(JSR227DataControlTreeNode.java:129)
    8. In my other "fresh" bc project I was able to use the newly created vo.
    9. When I added a VO to my shared project, all projects that are refering to the shared project loose their vo's in the data-controlpannel
    Do you have any suggestions?
    Regards,
    Romano

    Hi,
    since this appears to be a WebCenter related issue, I suggest to try the Webcenter forum WebCenter Portal or to log a bug
    Frank

  • Best small business switch for 100-300 user UC deployments

    Hello,
    The SMART Designs state that both the ESW500 and 300-series switches should not be used for deployments of over 100 IP phones.
    But now that both the UC560 can go up to 138 (128 IP phones) and the BE3000 can go up to 300 users is this design restriction still valid or is the Catalyst 2960 and above the only options?
    The QPT is still showing both the 300- and ESW500  switches as options for all versions of the UC560, and the 300- and 2960  switches are shown as valid options in the LAN for the BE3000.
    Thanks.

    Hi All,
    I would agree with the folks at smartdesign, but for a very differerent reason as suggested by kmacpherson..
    But think about the Business Edition 3000 (BE3000) and how it's supported.  BE3000 is supported by the traditional Cisco TAC that also supports the catalyst 2960S etc....
    The 300 series switch is supported by the wonder folk at the  Small Business Support Center (SBSC) . 
    300 series of switches are generations ahead of the ESW switch in terms of switch silicon/features/GUI/supported CLI/IPv6 support  etc..it is a tremendous switch series..
    From my perspective, even though there is now a lot of dialogue between TAC and SBSC these days, it sorta makes a lot of sense in my mind to position Catalyst switches  in conjunction with  BE3000 for your end users,  and 300 series small business switches as a lower cost alternative.
    This will mean there will be pretty seamless TAC support for a BE3000,  catalyst, ISRG2 solution.
    regards Dave

  • Help blocking certain website and IP on a SG 300-20 Small Business Switch

    Hi,
    I like to block certain IP and website on the SG 300-20.
    Being new to Cisco Small Business switch I she tried with no positive result. Could someone give me some steps or maybe direct me where I can find a step by step resource.
    Thank you

    Hello, 
    Thank you for contacting us for support with your device.
    Unfortunately what you are trying to do is not possible with any Small Business switch.
    It is true that this switch can be used in layer 3 and it will be able to route your traffic on the inside of the network, but it will not be able to route your traffic to the Internet as it doesn't do any NATting.
    If you need to block any websites you will need to configure it on your router or firewall.
    Just to be completely clear, this switch won't be able to block any websites.
    I hope this was helpful

  • LMS 3.2 and Cisco Small Business Switches

    Hi there,
    I'm currently using LMS 3.2 to monitor my network. We've recently purchsed a few of the Cisco Small Business Switches, the SF 300-24 model to be exact. They're considered 'managed switches' (tho thier CLI is terrible) and I would like to monitor them in CWLMS. My problem is that once I add it to CS, it doesn't resolve to anything, just sits there as a blue box with a question mark. I'm assuming this means that these devices are not (currently) supported by LMS 3.2 - do you know if that will change, or how I can go about managing this device with LMS 3.2?
    Thanks

    Unfortunately that series of products is not supported in any version of LMS (or even Cisco Network Assistant - CNA).
    Cisco provides the FindIt utility to manage them:
    http://www.cisco.com/en/US/products/ps10660/tsd_products_support_series_home.html
    Hope this helps.

  • Issue with executing Business Rules from Planning web

    Hi,
    We are using Hyperion Planning 9.3.0.1 and we keep getting an issue with the Business Rules. We get an error if we try to run the rules from Planning web. The same rules validates and executes fine if we run it from AAS. This issue gets resolved if we restart the Planning and RMI service. But this issue keeps happening randomly. Is there a permanent resolution to it? Is it a bug or I am missing something here?
    Thanks and Regards,
    Amol
    Edited by: user638718 on Apr 7, 2009 5:20 PM

    Hi,
    Have you installed any of the patches for 9.3.0.1, I think it goes up to 9.3.0.1.09
    One of the fixes was :-
    8-665086601 (6588823) – When the Business Rules connection to the relational database is lost, Business Rules does not reconnect to it. To solve this problem, an optional property, HBR_CONNECTION_VALIDATE_TIME, was added to HBRServer.properties. This property specifies a time interval for checking the connection between Business Rules and the relational database. If the connection is not valid, a new connection is established. The time interval is specified in milliseconds and defaults to 300,000 (five minutes).
    Though I know there has been more attention to fixing known issues on 9.3.1 than 9.3.0.1
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Issues with a SGE2000 switch

    It seems that the SGE2000 switch will lose the connections of systems after some period of time. I will ping a system and it will be slow or will not reply at all. See example below: C:\>ping 10.1.16.16 Pinging 10.1.16.16 with 32 bytes of data: Reply from 10.1.16.16: bytes=32 time=102ms TTL=63 Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Ping statistics for 10.1.16.16: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 102ms, Average = 25ms C:\>ping 10.1.16.16 Pinging 10.1.16.16 with 32 bytes of data: Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Reply from 10.1.16.16: bytes=32 time1ms TTL=63 Ping statistics for 10.1.16.16: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms I have made two changes; 1)The Aging Interval 630 the max. 2)Static MAC address entry. But nether of these changes have helped. Has anyone see issue with the SGE2000 switch? Thanks

    Thanks for the info. I have the latest firmware on the switch and resetting it doesn't help. I am route 7 IP networks via this switch with 24 systems on each network. I have statically added some of the systems MAC addresses to see if that would help, but same issue.

  • HT1277 how to configure mail OSX 10.9 (iMac) with Small Business Server 2003 ?

    How to set up mail on brand new iMac OSX 10.9 with Small Business Server 2003

    Can you clarify a little more? What part of SBS are you referring to when logging in? Via VPN? Remote Web Workplace? Etc?
    I administer a SBS2003 network and actually use a Macbook to do it all. Hopefully I'll be able to help!

  • Small Business switches and POODLE

    Has Cisco done any research into small business switches being vulnerable to POODLE?  I know they're working hard on the enterprise side, but I'm not finding any information on the small business side.
     

    Hi,
    All Cisco product will be checked and results are posted on the same page as for enterprise:
    http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20141015-poodle
    Regards,
    Aleksandra

  • Issues with connection busy functionality

    Here are a few things I've noticed with the busy connection functionality:
    If I want to right click in a SQL worksheet window while a tab has a query running (current or different tab) I get the "connection busy" error. Don't know why this is b/c right clicking should not be contacting the DB so it's not like I'm trying to run another process or something.
    I had one tab with a basic select statement and another that was running another script that was taking a while to execute. The tab running had a bunch of insert statements running but not in a pl/sql block. The script had 15,729 inserts. When I tried running a statement on the other tab, I recieved the "connection busy" error, and I clicked abort. Instead of not trying to connect, I kept recieving the "connection busy" error over and over. The second tab came back with results finally. When my other tab with the insert statements was done, I checked the number of rows in my table - 15,717! So it looks like when I was clicking abort the other script was skipping statements or something! Good thing I double checked b/c this nasty little bug would have caused me some grief in the future.

    The connection-busy-abort-retry dialog is popped us when a JDBC operation is being performed on the connection and another such operation is requested.
    SqlDeveloper uses single connection/session everywhere, so in your case, in the second worksheet, the same connection was being used which was busy through the operation in first worksheet.
    Right click on the worksheet, does some JDBC operation, hence you got the dialog in second worksheet.
    One workaround is to use unshared sql worksheet (ctrl-shif-n in a woeksheet).
    A better solution for above issues is being worked on by the development team that should give you better concurrency and responsiveness.
    This would be available in next major release of Sql Developer.
    -Raghu
    dev. team.

  • Logitech Keyboard Issues with Fast User Switching

    I'm running OSX 10.4 on an 800 MHz iMac, and using a Logitech Cordless Navigator keyboard. The keyboard's main feature (for me) is the ability to have the function keys (F1-F12) automatically open applications and folders and such. When I have multiple accounts running though, this feature seems to be tied to whichever one I first logged into. If I switch accounts and try to use one of the keyboard shortcuts nothing happens where I am, but when I switch back to the original account I find that the keyboard has opened the program there. The keyboard types fine in the new account, and I can even change the preferences so the function keys do different things in the different accounts, but the extra functionality seems to be only available for whichever account logs in first.
    I realize this may just be a Logitech bug, but any ideas how to fix this? (Also even though I'm the only one using my computer this seems like a mild security issue, if theoretically another user could activate programs on my account without the password.)
    800 MHz iMac G4   Mac OS X (10.4.3)   768 MB RAM

    Logitech support is frustrating:
    Dear tajmahall14,
    Thank you for your recent inquiry about your Keyboards.
    I understand you are having issues with the settings for the function keys becoming non-functional when fast switching from one user account to another.
    Depending on the system configuration, the Fast User Switching may or may not work. Unfortunately this is not an issue I can address. You may need to contact Apple to see if they have a possible solution to your problem.

  • Issue with "firstRecord" Business Component method of JAVA Data bean API.

    Hi,
    Following is my use-case scenario:
    I have to add or associate child MVG business component (CUT_Address)
    with the parent business component (Account) using JAVA Data bean API.
    My requirement is: first to check whether child business component(i.e. CUT_address) exists. If it exists then associate it with parent business component (Account)
    otherwise create new CUT_address and associate it with account.
    Code (using JAVA Data bean APIs) Goes as follows:
    SiebelBusObject sBusObj = connBean.getBusObject("Account");
    parentBusComp = sBusObj.getBusComp("Account");
    SiebelBusComp parentBusComp;
    SiebelBusComp childBusComp;
    // retrieve required account.. Please assume Account1 exists
    parentBusComp.activateField("Name");
    parentBusComp.clearToQuery();
    parentBusComp.setSearchSpec("Name", "Account1");
    sBusComp.executeQuery2(true, true);
    sBusComp.firstRecord();
    Counter = 0;
    while (counter < Number_Of_Child_Records_To_Insert)
    childBusComp = parentBusComp.getMVGBusComp("City");
    associatedChildBusComp = childBusComp.getAssocBusComp();
    childBusComp.activateField("City");
    childBusComp.clearToQuery();
    childBusComp.setSearchSpec("City", Vector_of_city[counter]);
    sBusComp.executeQuery2(true, true);
    if( sBusComp.firstRecord() )
    // Child already exist and do processing accordingly
    else
    // Child does not exist and do processing accordingly
    childBusComp.release();
    childBusComp = null;
    associatedChildBusComp.release();
    associatedChildBusComp=null;
    Now the issue with this code is: For the first iteration, SbusComp.firstRecord returns 0 if records does not exist. However from the second iteration, SbusComp.firstRecord returns 1 even if there is no record matching the search specification.
    Any input towards the issue is highly appreciable.
    Thanks,
    Rohit.

    Setting the view mode to "AllView" helped.
    Thanks for the lead!
    In the end, I also had to invoke the business component method SetAdminMode with "true" as the argument so that I could also modify the records from my script.

  • Issue with Citrix Business Objects full client

    Hi ,
    I have issue with my database pasword being expired. I ran a recovery and it works fine for me.
    Since we are using the citirx installation the bomain.key is available on the citrix server which is copied across the user profile when they are login into citrix server via the logon script.
    I still could not find whether the log on script is correct or not can any one of you let me know what I can use to copy the bomain.key using citrix usrlogon.cmd script.
    Regards,
    Ramesh

    Please post this query to the Business Objects Enterprise Administration forum:
    BI Platform
    That forum is monitored by qualified technicians and you will get a faster response there. Also, all BOE queries remain in one place and thus can be easily searched in one place.
    Thank you for your understanding,
    Ludek

  • Password issue with ESW 520 switches

    I was wondering if anyone else has run into or noticed an issue with passwords using these switches.  I've set up 5 or 6 in the past couple of months and have confirmed it is an issue with both the 2.0.3 firmware and the latest 2.1.16 firmware.
    The issue is that you cannot use an & in a password.  That is to say, you can use it when setting your new credentials for the switch but once set, you cannot login using this password any longer.  I've tested these passwords over and over, making sure I didn't slip off the shift key by removing caps or substituting a 7 instead of the & symbol.  I have NOT tried any other special characters but I can confirm that numbers work just fine.

    Sounds like a bug Chris.
    On Jul 9, 2010, at 10:29 AM, "c.holloway"

Maybe you are looking for