LabVIEW 2014 x64 AppCrash StackHash crash

Our application is crashing somewhat inconsistently in the x64 compile, but not the x32 compile.  We are using LabVIEW 2014.  When it crashes, LabVIEW stops responding and has to be closed from windows.  The View Details feature says it's AppCrash and further says StackHash_someHEXnumber.   Another member of the team analyzed dump files and seemed to think it's crashing in the LabVIEW run time.  
Any known issues out there that would explain this?  
It happens on the original release of LV2014x64 and SP1.  It happens in LabVIEW and in a compiled executable.  If is not consistent, if we open the software and start running tests, sometimes it will never crash, other times it will crash before 1500 test runs.  Our way of testing this has been to run 1500 runs, then close it then reopen it, run again.  If it doesn't crash within 3 times of doing 1500 runs, we say that the crash probably isn't going to happen in that version of the software.  So we've been selectively disabling parts of the software trying to figure out which code is triggering the crash.

Some more information:
In addition to not happening in LV2014x86, it does not happen in LV 2014 MacOS x64.  So this is specific to LV 2014 Windows x64.  Furthermore, if we save our code to previous and open it in LV2013x64 there's no crash (there's some hickups with the downgrade so it's not 100% apples-apples though) .
We have narrowed the crash down to a specific changelist in source code control.  In that changelist we changed the architecture of how we pass messages around in our program.  We used to use User Events to pass messages and the vi listening would subscribe to the user event.  However, we found this created a memory leak in LV2012.  So we switched to a queued based messaging architecture in this changelist.  We created a variant which held the queues as a variant attribute associated with the message enum.  This was so that when a message is sent we could do a fast lookup by taking the message and getting a varriant attribute associated with it (thus giving us the queues subscribing to that message).  When we introduced this in LV2012 we stressed tested it all and it worked great.  Later we upgraded to LV2014 and that's when the crashing started, we have gone back to this specific changelist and tried it with LV2014 it crashes.
We have found other parts of our code which if we disable the crashing goes away.  Our suspicion is that this occurs due to a perfect storm of calling vi's asyncronously (which call other vi's ascncronously), passing messages to them via queues, and maybe the variant's containing queues in attributes.  Based on what various programmers have seen via a variety of observations, our suspicions are that some combination of those circumstances is triggering some sort of LV2014 windows x64 bug.

Similar Messages

  • File dialog crashes LabVIEW 2014 on Mac OSX Yosemite

    I know that Mac OS 10.10 (Yosemite) is not technically supported by LabVIEW 2014. If that's the only answer to this question, then so be it.
    The following causes LabVIEW 2014 to crash on Mac OSX 10.10 (Yosemite):
    1. Run the native File Dialog in LabVIEW 2014 (Express VI) , using "New or Existing File" as the selection mode
    2. Select "New File..." when the file dialog appears
    3. Enter anything as the file name and click OK
    4. LabVIEW either crashes immediately, or hangs indefinitely and must be force quit.
    Is there an update for LV 2014 (and the RTE) that does support Yosemite?
    This bug makes deploying apps to the Mac basically impossible, Yosemite is the latest OS. Does anyone have a workaround for the issue?
    Thanks.

    LabVIEW 2014 SP1 seems to solve that problem here on my Mac OSX 10.10 system.
    Now Apple may be nice for end users, but all those Apple fan boys sure would think a little different about it, if they had to write programs on the Mac. Apple keeps changing its APIs and their behaviour continously, inventing new APIs (which is fine) in a rapid pace, only to depreciate and remove older APIs at almost the same speeed!
    Microsoft sometimes goes to the other extreme with maintaining backwards compatibility but working with Apple systems surely isn't easy as a programmer (unless maybe when one uses their high level click and point together web design applications, but I don't know that).
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Labview 2014 crashing(windows 7)

    Hello for some reason my labview 2014 crashes when i try to open the labview application. It was working fine until yesterday but not having any luck today. Also i cannot see my labview software in the programs and feature section on the control panel even though i have administrative privileges in my computer. I have attached my error report below.Any help would be appreciated.
    Attachments:
    crash_report.PNG ‏109 KB

    Hi go_sa,
    In Programs and Features are you looking under National Instruments Software for LabVIEW 2014? If so, and LabVIEW is not listed, have you tried re-installing the software?
    If it is listed under National Instruments Software, it sounds like there may be some software corruption causing the error. The next step would be to try repairing the program. If this does not work, you can try force re-install the program (link below) or uninstalling and reinstalling it.
    http://digital.ni.com/public.nsf/allkb/ADD22E807D5A12AD862579EC00760F79
    Julia P.

  • Premire Pro CC 2014 and Media Encoder Crash During Launch

    Premire Pro and Media Encoder crash during startup and are unusable. I am using Windows 7 Ultimate and already tried reinstalling Adobe Creative Cloud from scratch and it's still happening. I also tried following Adobes KB articles directions to rename the Adobe folder in my documents and appdata to no avail. When I try to launch either application, I get a generic windows crash message "Adobe Premire Pro CC 2014.0 has stopped working" and when I click problem details, it lists this:
    Problem signature:
      Problem Event Name: APPCRASH
      Application Name: Adobe Premiere Pro.exe
      Application Version: 8.0.0.169
      Application Timestamp: 536f4f89
      Fault Module Name: ImageRenderer.dll
      Fault Module Version: 8.0.0.169
      Fault Module Timestamp: 536f2c18
      Exception Code: c000001d
      Exception Offset: 00000000001f5382
      OS Version: 6.1.7600.2.0.0.256.1
      Locale ID: 1033
      Additional Information 1: 0b2d
      Additional Information 2: 0b2df4702c3fc6489bf922fb8e966350
      Additional Information 3: fa9f
      Additional Information 4: fa9f59f642d335ee71c6667e52000d39

    I am having a similar problem.
    Premiere Pro CC 2014 suddenly decided to crash every time I export to either Adobe Media Encoder or within Premiere itself.
    The encode will usually go for 5-10 minutes before the programs either spits out a "serious error has occurred" window, or it just sits there frozen until I force quit.
    I did find a work-around for the moment. If I open AME and FILE > OPEN, select my project and then the sequence I want, AND put it in Software render mode, it will work.
    My timeline is 2K, 58 minutes in 23.976
    Only effects applied are Lumetri LUTs - no third party.
    I've exported as recently as a week ago without issue.
    Running OSX 9.5 on an X99 board
    3.75 GHz 8-core
    64GB 2400 MHz RAM
    EVGA Titan Black 6GB
    Because I can get my renders out, I am not too concerned. Either there is something wonky with my timeline that screws with any graphics enabled rendering, or there is a bug that is have the same effect. I will try rendering on another of my edit bays that utilizes a GTX 580 that I KNOW works. The Titan is pretty new to my workflow.
    Thanks Adobe, for checking this out.

  • Open vi reference conversion from Labview 6 to Labview 2014

    Is there a way that someone can help me convert this VI written in Labview 6.1  so that I can work en EXE in Labview 2014.
    I succed to open this vi from 6.1 to 2014 but it does not run. The open vi reference those not work in exe program. Someone know how I can  replace that function...
    Thanks!
    Solved!
    Go to Solution.
    Attachments:
    to convert 2104.zip ‏17 KB

    Error 7 is File Not Found.  So your dynamically called VI is not in your executable.
    In the build spec for the executable in your project, there is a section for "Source Files".  On of the options for the VIs is "Always Include".
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Compile 9076 with LabVIEW 2014 Worked good with 2012 SP1

    An internal software error has occurred. Please contact National Instruments technical support at ni.com/support with the following information:
    Error 7 occurred at Open VI Reference in nirviOpenVIRefByNameOrPath.vi->niFpgaRemapObjsAndListIfUnderXNode.vi->niFpgaRemapObjsHandleXNodeSubErrors.vi->nirviMassageErrorList.vi->niFpgaErrorDialog_ParseErrors.vi->niFpgaErrorDialog_ReadErrorData.vi->niFpgaGenerateCode_ErrorDialog.vi
    Possible reason(s):
    LabVIEW:  File not found. The file might be in a different location or deleted. Use the command prompt or the file explorer to verify that the path is correct.
    VI Path: C:\Program Files\National Instruments\LabVIEW 2014\rvi\CodeGenErrorUtilities\Diagram Constant
    All text parsed:
    <CodegenErrorList>
              <CodeGenErr>
                <ErrorCode>-64001</ErrorCode>
                <DynamicText>
                  <TreeLineInfo>
                    <TreeInfo>
                      <TreeID>1</TreeID>
                    </TreeInfo>
                  </TreeLineInfo>
                </DynamicText>
              </CodeGenErr>
              <CodeGenErr>
                <ErrorCode>-64001</ErrorCode>
                <DynamicText>
                  <TreeLineInfo>
                    <TreeInfo>
                      <TreeID>1</TreeID>
                    </TreeInfo>
                  </TreeLineInfo>
                </DynamicText>
              </CodeGenErr>
              <CodeGenErr>

    Hi Nieman,
    You have the right compilers for your FPGA targets, based on KB 609GUVBT.
    Error -64001 indicates that there is an issue with one of the nodes in your VI. Since you are able to compile a blank FPGA VI, then you should try to identify the node that is causing this problem. When trying to pinpoint this node, I’d recommend executing your FPGA VI with simulated I/O on the development machine, as described in KB 3W6EFRLX,
    Also, are you able to reproduce this issue when running one of the LabVIEW Example Finder FPGA VIs that targets your NI 9076? You can find these examples in the Example Finder's  Hardware Input and Output>>CompactRIO section.
    Regards,
    Tunde S.
    Applications Engineer
    National Instruments

  • Error 997. Overlapped I/O operation is in progress during SQL Server 2014 X64 Express

    I am trying to install SQL Management Studio from SQL Server 2014 X64 Express, however during installation, getting multiple identical errors:
    Error 997. Overlapped I/O operation is in progress
    Previously, someone posted similar question http://blogs.msdn.com/b/vsnetsetup/archive/2014/10/27/error-997-overlapped-i-o-operation-is-in-progress-kb2918614-breaks-windows-installer-service.aspx It was suggested to uninstall: KB3000988, KB2918614, I did so,
    but it didn't help. Also, tried to modify registry to add "product code" using ORCA tool. Maybe, I used wrong codes ? Thank you !
    Here is installation log:
    Overall summary:
      Final result:                  Failed: see details below
      Exit code (Decimal):           -2068053019
      Start time:                    2015-04-02 17:07:19
      End time:                      2015-04-02 17:11:42
      Requested action:              Install
    Setup completed with required actions for features.
    Troubleshooting information for those features:
      Next step for Adv_SSMS:        Use the following information to resolve the error, and then try the setup process again.
      Next step for SSMS:            Use the following information to resolve the error, and then try the setup process again.
      Next step for ComponentUpdate: Use the following information to resolve the error, and then try the setup process again.
    Machine Properties:
      Machine name:                  POSEIDON
      Machine processor count:       4
      OS version:                    Windows 7
      OS service pack:               Service Pack 1
      OS region:                     United States
      OS language:                   English (United States)
      OS architecture:               x64
      Process architecture:          64 Bit
      OS clustered:                  No
    Product features discovered:
      Product              Instance             Instance ID                   
    Feature                                  Language            
    Edition              Version         Clustered  Configured
      SQL Server 2005                                                         
    Tools                                    1033                
    Express Edition      9.4.5000        No         Yes       
      SQL Server 2005                                                         
    ToolsClient                              1033                
    Express Edition      9.4.5000        No         Yes       
      SQL Server 2005                                                         
    ToolsClient\Connectivity                 1033                 Express Edition     
    9.4.5000        No         Yes       
      SQL Server 2008 R2   SQLEXPRESS           MSSQL10_50.SQLEXPRESS          Database Engine Services                
    1033                 Express Edition      10.51.2500.0    No         Yes     
      SQL Server 2008 R2   SQLEXPRESS           MSSQL10_50.SQLEXPRESS          SQL Server Replication                  
    1033                 Express Edition      10.51.2500.0    No         Yes     
      SQL Server 2008 R2                                                      
    Management Tools - Basic                 1033                 Express Edition     
    10.51.2500.0    No         Yes       
    Package properties:
      Description:                   Microsoft SQL Server 2014
      ProductName:                   SQL Server 2014
      Type:                          RTM
      Version:                       12
      SPLevel:                       0
      Installation location:         C:\Users\Alex\Desktop\SQLEXPRADV_x64_ENU(1)\x64\setup\
      Installation edition:          Express
    Product Update Status:
      None discovered.
    User Input Settings:
      ACTION:                        Install
      ADDCURRENTUSERASSQLADMIN:      true
      AGTSVCACCOUNT:                 <empty>
      AGTSVCPASSWORD:                <empty>
      AGTSVCSTARTUPTYPE:             Manual
      ASBACKUPDIR:                   Backup
      ASCOLLATION:                   Latin1_General_CI_AS
      ASCONFIGDIR:                   Config
      ASDATADIR:                     Data
      ASLOGDIR:                      Log
      ASPROVIDERMSOLAP:              1
      ASSERVERMODE:                  MULTIDIMENSIONAL
      ASSVCACCOUNT:                  <empty>
      ASSVCPASSWORD:                 <empty>
      ASSVCSTARTUPTYPE:              Automatic
      ASSYSADMINACCOUNTS:            <empty>
      ASTEMPDIR:                     Temp
      BROWSERSVCSTARTUPTYPE:         Disabled
      CLTCTLRNAME:                   <empty>
      CLTRESULTDIR:                  <empty>
      CLTSTARTUPTYPE:                0
      CLTSVCACCOUNT:                 <empty>
      CLTSVCPASSWORD:                <empty>
      CLTWORKINGDIR:                 <empty>
      COMMFABRICENCRYPTION:          0
      COMMFABRICNETWORKLEVEL:        0
      COMMFABRICPORT:                0
      CONFIGURATIONFILE:             
      CTLRSTARTUPTYPE:               0
      CTLRSVCACCOUNT:                <empty>
      CTLRSVCPASSWORD:               <empty>
      CTLRUSERS:                     <empty>
      ENABLERANU:                    false
      ENU:                           true
      ERRORREPORTING:                false
      FEATURES:                      SSMS, ADV_SSMS
      FILESTREAMLEVEL:               0
      FILESTREAMSHARENAME:           <empty>
      FTSVCACCOUNT:                  <empty>
      FTSVCPASSWORD:                 <empty>
      HELP:                          false
      IACCEPTSQLSERVERLICENSETERMS:  true
      INDICATEPROGRESS:              false
      INSTALLSHAREDDIR:              C:\Program Files\Microsoft SQL Server\
      INSTALLSHAREDWOWDIR:           C:\Program Files (x86)\Microsoft SQL Server\
      INSTALLSQLDATADIR:             <empty>
      INSTANCEDIR:                   C:\Program Files\Microsoft SQL Server\
      INSTANCEID:                    <empty>
      INSTANCENAME:                  <empty>
      ISSVCACCOUNT:                  NT AUTHORITY\Network Service
      ISSVCPASSWORD:                 <empty>
      ISSVCSTARTUPTYPE:              Automatic
      MATRIXCMBRICKCOMMPORT:         0
      MATRIXCMSERVERNAME:            <empty>
      MATRIXNAME:                    <empty>
      NPENABLED:                     0
      PID:                           *****
      QUIET:                         false
      QUIETSIMPLE:                   false
      ROLE:                          AllFeatures_WithDefaults
      RSINSTALLMODE:                 DefaultNativeMode
      RSSHPINSTALLMODE:              DefaultSharePointMode
      RSSVCACCOUNT:                  <empty>
      RSSVCPASSWORD:                 <empty>
      RSSVCSTARTUPTYPE:              Automatic
      SAPWD:                         <empty>
      SECURITYMODE:                  <empty>
      SQLBACKUPDIR:                  <empty>
      SQLCOLLATION:                  SQL_Latin1_General_CP1_CI_AS
      SQLSVCACCOUNT:                 <empty>
      SQLSVCPASSWORD:                <empty>
      SQLSVCSTARTUPTYPE:             Automatic
      SQLSYSADMINACCOUNTS:           <empty>
      SQLTEMPDBDIR:                  <empty>
      SQLTEMPDBLOGDIR:               <empty>
      SQLUSERDBDIR:                  <empty>
      SQLUSERDBLOGDIR:               <empty>
      SQMREPORTING:                  false
      TCPENABLED:                    0
      UIMODE:                        AutoAdvance
      UpdateEnabled:                 true
      UpdateSource:                  MU
      USEMICROSOFTUPDATE:            false
      X86:                           false
      Configuration file:            C:\Program Files\Microsoft SQL Server\120\Setup Bootstrap\Log\20150402_170710\ConfigurationFile.ini
    Detailed results:
      Feature:                       Management Tools - Complete
      Status:                        Failed: see logs for details
      Reason for failure:            An error occurred for a dependency of the feature causing the setup process for the feature to fail.
      Next Step:                     Use the following information to resolve the error, and then try the setup process again.
      Component name:                Microsoft Visual Studio 2010 Redistributables
      Component error code:          997
      Component log file:            C:\Program Files\Microsoft SQL Server\120\Setup Bootstrap\Log\20150402_170710\VC10Redist_Cpu64_1.log
      Error description:             Error 997.Overlapped I/O operation is in progress.
      Error help link:               http://go.microsoft.com/fwlink?LinkId=20476&ProdName=Microsoft+SQL+Server&EvtSrc=setup.rll&EvtID=50000&ProdVer=12.0.2000.8&EvtType=vc_red.msi%40ProcessComponents%40997
      Feature:                       Management Tools - Basic
      Status:                        Failed: see logs for details
      Reason for failure:            An error occurred for a dependency of the feature causing the setup process for the feature to fail.
      Next Step:                     Use the following information to resolve the error, and then try the setup process again.
      Component name:                Microsoft Visual Studio 2010 Redistributables
      Component error code:          997
      Component log file:            C:\Program Files\Microsoft SQL Server\120\Setup Bootstrap\Log\20150402_170710\VC10Redist_Cpu64_1.log
      Error description:             Error 997.Overlapped I/O operation is in progress.
      Error help link:               http://go.microsoft.com/fwlink?LinkId=20476&ProdName=Microsoft+SQL+Server&EvtSrc=setup.rll&EvtID=50000&ProdVer=12.0.2000.8&EvtType=vc_red.msi%40ProcessComponents%40997
      Feature:                       Setup Support Files
      Status:                        Failed: see logs for details
      Reason for failure:            An error occurred for a dependency of the feature causing the setup process for the feature to fail.
      Next Step:                     Use the following information to resolve the error, and then try the setup process again.
      Component name:                Microsoft Visual Studio 2010 Redistributables
      Component error code:          997
      Component log file:            C:\Program Files\Microsoft SQL Server\120\Setup Bootstrap\Log\20150402_170710\VC10Redist_Cpu64_1.log
      Error description:             Error 997.Overlapped I/O operation is in progress.
      Error help link:               http://go.microsoft.com/fwlink?LinkId=20476&ProdName=Microsoft+SQL+Server&EvtSrc=setup.rll&EvtID=50000&ProdVer=12.0.2000.8&EvtType=vc_red.msi%40ProcessComponents%40997
    Rules with failures:
    Global rules:
    Scenario specific rules:
    Rules report file:               C:\Program Files\Microsoft SQL Server\120\Setup Bootstrap\Log\20150402_170710\SystemConfigurationCheck_Report.htm

    Hi Alexander,
    According to your description, you encounter the error 997 when installing SQL Server 2014 Management Studio. This issue could be due to the account problem or third-party software scanning. Besides paSQuaLe's post, you could also check the following things.
    1. Check the account with which you log on to the server, make sure that it is not an account with temporary profile.
    2. Run SQL Server setup file locally on your computer and make sure that you choose ‘Run as administrator’ to run the setup.
    3. Disable any Anti-virus and reboot your server.
    4. Check for any problems with disk drive where you are installing SQL Server files.
    Regards,
    Michelle Li

  • Adobe Premiere Pro CC 2014 keeps lagging and crashing

    My Adobe Premiere Pro CC 2014 keeps lagging and crashing to a point where I cannot do my job. When I open my premiere file, I can work on my timeline for maybe two or three minutes before it lags, freezes, and then finally crashes. I'm at a loss of what exactly is causing my problem because I edit primarily H.264 files and my sequences are not complex in any sense of the word. I've been dealing with this for days and I cannot seem to find a solution. If anyone has any advice please let me know because I am desperate. Thank you.
    Specs:
      Model Name: Mac Pro
      Model Identifier: MacPro6,1
      Processor Name: Quad-Core Intel Xeon E5
      Processor Speed: 3.7 GHz
      Number of Processors: 1
      Total Number of Cores: 4
      L2 Cache (per Core): 256 KB
      L3 Cache: 10 MB
      Memory: 16 GB
      Boot ROM Version: MP61.0116.B05
      SMC Version (system): 2.20f18
      Illumination Version: 1.4a6

    Hi Dana,
    Can you go to File-Project Settings-General and change the video renderer to Software Only Mode.
    Check if that works or not.
    Are you using any third party plug-in's for Premiere Pro?
    Thank You
    Arjun

  • Labview 2014 Excel Active X Property Nodes disabled - Why?

    Hello,
    I am using Labview 2014 and want to open, write to and close Excel by the use of Active X.
    I am confronted with the problem, that, if connecting (Active X-) property nodes to the references (e.g. "Excel_Application"), right-clicking on the context menue doesn´t let me choose any properties, the item is disabled (one can read in German "Keine Eigenschaften" (no properties)).
    How can I resolve this? What am I doing wrong?
    Thank you!

    I am having the same problem.  When I left click to choose/change the property I do not get a list - instead I get the greyed No Properties popup - see screenshot.
    If I drag and drop an existing property node from within an example subVI it connects to the reference and keeps showing the current property but I cannot change to a different one.
    I am using LV 2012, Win7, Office 2013.
    When I try with LV 2012, Win7, Office 2010, it works properly.  So my guess is that is has to do with the version of office.  But I would like to know the reason why as well.
    Attachments:
    NoProperties.png ‏67 KB

  • The last time you ran LabVIEW, an internal error or crash occurred at source/typedesc/DSTM.cpp, line 211.

    Nickled and dimed once again by obscure errors. This is LabVIEW 10.0.1 on Redhat EL 5.5 32-bit.
    I removed an enum from the project that is also used in a typedef control cluster. Since many VIs use this typedef I have to go to each VI and save in order to remove the phantom dependencies (i.e. popup can't find enum ctl when opening VIs). In the process of opening every VI and saving LabVIew is crashing on me reliably but not everytime just after I press cancel when it tries to find the enum ctl.
    Here are the errors. Sometimes the address is null....I believe LabVIEW src code should check for null/bad pointers but does not in this case.
    GenNAryOp_ArrayBase : naryop, setdef? ninp=1
    Compiler error.  Report this problem to National Instruments Tech Support.
    copy cvt str/pict/tag, csrc=0xFF
    Compiler error.  Report this problem to National Instruments Tech Support.
    copy cvt, csrc=0x21
    Compiler error.  Report this problem to National Instruments Tech Support.
    copy cvt bool, csrc=0x30
    Compiler error.  Report this problem to National Instruments Tech Support.
    copy cvt str/pict/tag, csrc=0xA
    Compiler error.  Report this problem to National Instruments Tech Support.
    copy cvt, csrc=0x50
    LabVIEW caught fatal signal
    10.0.1 - Received SIGSEGV
    Reason: address not mapped to object
    Attempt to reference address: 0x0xffffffff
    Upon reopening LV I see this.
    The last time you ran LabVIEW, an internal error or crash occurred at source/typedesc/DSTM.cpp, line 211.

    Hello wbdoyle,
    I'm sorry you are seeing that error. Did you close and save the type def that included the enum? This should prevent you from having to go through and save each VI that includes the type def.  Are you using the System Exec VI? Also, are you performing any data acquisition with the VI you are referencing? The error you are seeing indicates that the LV compiler isn't handling something in your VI and I want to pinpoint exactly what is happening.
    Thanks!
    Regards,
    Anna L
    Applications Engineer
    National Instruments

  • Making labview 2014 and Access 2013 db working correctly

    Hi all,
    i'm trying to gain access to a database created by Access 2013 from Labview 2014. Since we dont want to buy the NI toolkit i thought to use the old LabSQL library. Has anyone tried to do the same thing or give me some hints about it?
    Actually i have tryed to run the example shipped with LabSQL but i received an error:
    Exception occured in Microsoft OLE DB Provider for ODBC Drivers: [Microsoft][Driver Manager ODBC] Nome origine dati non trovato e driver predefinito non specificato. in ADO Connection Open.vi->Example - Fetch a Table.vi
    Reading the README file of the LabSQL i found this:
    2. As with any database application on Windows, you'll need to create a DSN (Data Source Name) in the ODBC control panel. This DSN is used in your LabVIEW application to connect to the appropriate database. If you want to set up the example database, do the following:
        a.Go to your Windows Control Panels, and open "ODBC Data Sources"
        b.Click on the "System DSN" tab
        c.Click on the "Add..." button.
        d. From the list of drivers, choose "Microsoft Access Driver"
        e.At the dialog box, type in "myDB" for the Data Source Name. Then click on "Select..." button, and find the file "Sample Database.mdb" included with the LabSQL examples. Leave everything else as it is, and hit OK.
        f. Close the ODBC control panel
        g. Test the connection by running one of the examples provided.
    My problem is that i can't find the driver named "Microsoft Access Driver" so i can't continue through the points of the instructions. I only found "SQL Server" and "SQL Server Native Client 11.0" but if i select one of this the dialog box that appear later is different from the one described in the README instructions...

    You can certainly access the database without the toolkit. There are drivers that I posted on the forum and I have a small complete application on my blog -- you can even download the code from my SVN repository.
    In terms of you specific problem, you don't need a DSN. What you need is something called a "connection string". Also, don't waste your time with ODBC. The built-in ADO drivers are easier to use. Again, check my posts for details -- I did a 3-part series on database connectivity.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • LabVIEW 2009 x64 and applicatio​n builder

    Hi
    My organisation has just got a site licence for LabVIEW so I have just installed 2009 x64.
    My question is this:
    If I build applications written using LabVIEW 2009 x64, will they only run on 64 bit computers? I would test this but both my computers are 64 bit machines. I have had a brief look through the build specs but there doesn't seem to be anything about 32/64 bit compatibility.
    thanks.

    Solved!
    Go to Solution.

    Does this help?
    http://digital.ni.com/public.nsf/allkb/71E9408E6DE​AD76C8625760B006B6F98
    Q. Can I run an executable built with LabVIEW 64-bit on a 32-bit PC?
    A. You cannot run the LabVIEW 64-bit Development System, Run-Time Engine, or executables on a 32-bit PC.
    Q. Can I run an executable built with LabVIEW 32-bit on a 64-bit PC?
    A. Windows can run 32-bit executables on a 64-bit PC. Therefore, the LabVIEW 32-bit Development System, Run-Time Engine, and executables can be run on Windows 64-bit.
    Q. Can I have both LabVIEW 32-bit and LabVIEW 64-bit installed on the same 64-bit machine?
    A. Yes.
    Q. Can I build a 32-bit version of an executable from the LabVIEW 64-bit application builder?
    A. There currently is not an option to create a 32-bit version of an executable from the LabVIEW 64-bit application builder.

  • Unknown error when adding a DAQ assistant to a blank VI in LabView 2014

    Hello,
    I currently have an issue when I try to add a DAQ assistant to a blank VI  in LabView 2014 Service Pack 1, version 14.0.1.
    It was working previously and has now stopped working.  I have reinstalled LabView 2014 but the problem still exists.
    I have also reinstalled NI-DAQmx 14.5 but this did not cure the problem either.  
    I have made sure that the C:\Program files\National Instruments\MAX folder has Read & execute, List folder contents, Read function allowed for the user account in use on Windows 8.1
    Thanks in advance for the help.
    Scott.

    As soon an the DAQ assistant is dropped onto the VI block diagram an error window pops up stating that "An unknow error has occurred" with an ok button.   This does not force LV to close, the DAQ assistant icon stays on the block diagram, the block is non functional i/o signals available to wire to, I can not access any properties for the DAQ assistant.  Other than that LV appears to be functioning.

  • Bug LABVIEW 2014 - Calcul Quotient et Reste

    Bonjour à tous,
    Avez-vous remarqué ce bug dans labview 2014 sur la fonction quotient et reste?
    J'ai lu sur le forum anglais que le bug a déjà été vu en 2009. Il est à nouveau présent!
    C'est la seconde fois que je tombe dessus et qui m'oblige à utiliser un "patch maison", mais cette fois j'en informe la communauté:
    Par exemple dans mon cas 8.6 / 0.1 = 85 et reste 0.1... (voir PJ).
    Merci aux personnes concernées de prendre en compte ce bug dans vos prochaines mises à jour car c'est une fonction assez basique...
    Bonne journée.
    Julien P.
    Certified LabVIEW Developer
    Résolu !
    Accéder à la solution.
    Pièces jointes :
    quotient.vi ‏7 KB

    Bonjour à tous les deux,
    En effet, comportement particulier mais qui n'est pas un bug.
    Le "souci" vient des règles qui régissent la façon dont sont arrondis les nombres à virgule:
    IEEE Rounding rules
    C'est pour celà que dans l'aide détaillée de la fonction une remarque est présente (cf Quotient et reste (fonction)):
    "Remarque  Certains nombres réels ne peuvent pas être représentés par les nombres à virgule flottante de la norme ANSI/IEEE. Il est donc possible que des erreurs d'arrondi surviennent et que LabVIEW produise des résultats inattendus si vous utilisez les nombres à virgule flottante avec cette fonction. Pour obtenir des comparaisons et des calculs exacts, convertissez les nombres à virgule flottante en entiers."
    Bonne journée,
    Valentin
    Certified TestStand Architect
    Certified LabVIEW Developer
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    Travaux Pratiques d'initiation à LabVIEW et à la mesure
    Du 2 au 23 octobre, partout en France

  • I am using 4K Footages for editing in Premiere pro CC 2014, but its getting crash in between at every 15 to 20 mins. Kindly suggest how can it be solved, does any plugins or settings needed to edit 4K footages? Also would like to mention that footages fra

    I am using 4K Footages for editing in Premiere pro CC 2014, but its getting crash in between at every 15 to 20 mins. Kindly suggest how can it be solved, does any plugins or settings needed to edit 4K footages? Also would like to mention that footages frame rates are 29.97 and i have set timeline to 25 FPS is requirement by client. kindly revert. Thanks

    Thanks Richarad ..It has solved the problem but still crashes some times .As the programme has the break (bumper)after every five minutes ,i hope it will not compress bumper time too after export.

Maybe you are looking for

  • How to open a .sol file?

    I'm trying to acess a .sol file of mine, but a pop up keeps on appearing- "Apple Script Editor cannot open files in the Apple Script Editor Document format." I just want to know- is there someway I can open said file, or something I can download to a

  • Weblogic not startng after configuring weblogic92 with soa-suite 10.1.3.4

    Configurig WebLogic 9.2 with soa-suite 10.1.3.4 .New domain has been created sucessfully.Wheh tried to start weblogic using command in C:\bea\user_projects\domains\SOADomain\bin Error comes : Provider javax.xml.stream.XMLInputFactory could not be ins

  • ORB services not started in OAS 4.0.7

    Hi, I have installed Oracle Application server 4.0.7 on NT server 4.0 with service pack 4. OAS installed successfully . When I am trying to start all options of the OWS services , it gives the message "waiting for ORB to be ready...." and after somet

  • Batch size change

    Hi All, In bridge I have a lot of large images I want to change to 72 X  640 X 640.  If I go to PS under script I can change to the 640 X 640 but not the 72.  How can I do this all at one time instead of one at a time? Thanks much, Al

  • Asking about read voltage.vi

    i'am pretty confused about reading voltage.vi where i dont know where all numbers come. Can i use it directly for reading stauff or tachometer ? anw, what is board ID and channels ? is there any pictures for both ? sorry for silly questions noobs her