LabVIEW and NI Careers - UK

Hi, I am looking for a number of people who are looking to start a career or have existing experience in a LabVIEW or a National Instruments environment. I have developed relationships with almost all of the NI alliance partners across the UK and I am always looking for good people with passion that want to develop. If you or anyone else you know would be interested in hearing about the current opportunities across the UK please contact me either by replying to this blog or on: [email protected] or my direct line is: +44 (0) 1275 813 672 Many thanks, Ashley Malpas   (Unfortunately I am unable to process any application unless you have the right to work in the UK either through UK or EU residence or a current British work permit being in place i.e. HSMP. Because of this I ask that you only apply if this is relevant to you. Thank you.)

Hi Ashley,,
I am Praveen from nottingham UK ,I have got hsmp visa and right to work in UK,I am looking for career opportunities in labview as i got knowledge about labview in my past experience,i have completed engineering in 2005 in E&C ,please suggest me the chances in UK,

Similar Messages

  • I am receiving the data through the rs232 in labview and i have to store the data in to the word file only if there is a change in the data and we have to scan the data continuasly how can i do that.

    i am receiving the data through the rs232 in labview and i have to store the data in to the word or text file only if there is a change in the data. I have to scan the data continuasly. how can i do that. I was able to store the data into the text or word file but could not be able to do it.  I am gettting the data from rs232 interms of 0 or 1.  and i have to print it only if thereis a change in data from 0 to 1. if i use if-loop , each as much time there is 0 or 1 is there that much time the data gets printed. i dont know how to do this program please help me if anybody knows the answer

    I have attatched the vi.  Here in this it receives the data from rs232 as string and converted into binery. and indicated in led also normally if the data 1 comes then the led's will be off.  suppose if 0 comes the corresponding data status is wrtten into the text file.  But here the problem is the same data will be printed many number of times.  so i have to make it like if there is a transition from 1 to o then only print it once.  how to do it.  I am doing this from few weeks please reply if you know the answer immediatly
    thanking you 
    Attachments:
    MOTORTESTJIG.vi ‏729 KB

  • Problem with Labview and an ARM Cortex

    Good morning,
    I am currently trying to use Labview with a board from ST Microelectronics (MCBSTM32) with an ARM Cortex Processor.
    I use the SDK and have followed the tutorials.
    But, when I try to launch the program (the simple loop as write in the tutorial n°2 : http://zone.ni.com/devzone/cda/tut/p/id/7029 ), Keil gives me an error via Labview:
    "Argument 'DARMSTM' not permitted for option 'device'."
    It seems that Keil does not allow an ARM Cortex from ST as the device.
    Moreover, after having this problem, I am unable to use a Keil project ,even a project which worked before, without Labview. I need to restart the computer.
    I also try to launch the Keil project generated by Labview, without using Labview, and it works. But as soon as I use Labview, I have the error.
    Did anyone already have this error or know how to solve it
    Thank you for your answer and sorry for my bad english.
    Regards,
    Raphaël VAISSIERE

    Hi Raphi,
    So let me make sure I understand,
    The project created in LabVIEW errors out with the message "Argument 'DARMSTM' not permitted for option 'device" 
    If you open the same project in Keil uVision, it runs fine
    Here are my questions:
    1. So how does the code run when run through Keil? does it deploy and run fine?
    2. Did you follow the porting procedure completely?
    Your target STM32F103RB  is techincally supported by Keil but you need to port the RTX kernel to it. This paragraph explains it:
    To determine if your target already supports the RTX Real-Time Kernel, browse to the \Keil\ARM\Startup directory, then browse to the folder that corresponds to the manufacturer of your ARM microcontroller. If there is an RTX_Conf*.c file for your target, then the RTX Real-Time Kernel has already been ported for your ARM device. If no such file exists, skip to chapter 4 for more information on the RTX Real-Time Kernel and a guide for porting RTX to your ARM microcontroller. 
    You also need to port the Real-Time agent to it.
    I just want to make sure that you have followed the guidelines. If you have and are still having problems, we will continue to explore this.
    Thanks,
    National Instruments
    LabVIEW Embedded Product Support Engineer

  • I am trying to use Labview and RP1210 compliant hardware to connect to a truck J1939 bus and receive messages.

    I am trying to use Labview and RP1210 compliant hardware to connect to a truck J1939 bus and receive messages. 
    Specifically I am attempting  to read data frames using the RP1210_READMESSAGE .   am able to configure the hardware and send a message to the J1939 bus. .    I think I have not configured something correctly.  I can use the RP1210_SENDMESSAGE and see the message I have sent on the bus using CANalyzer   When I use the RP1210_READMESSAGE   I get the timestamp from a message and the return from the function sends back the correct number of bytes (the number matches the number of bytes I sent out plus four bytes from the timestamp).  What I am having trouble with is actually receiving the data. I have had the same type of behavior from two different hardware (Vector CANcase XL and Nexiq USB Link), so I don't think the issue is vendor specific.
    Has anyone been able to make the RP1210_RECIEVEMESSAGE function work correctly?
    Thanks for any help

    Thanks
    I have already tried that.  The links are the NI RP1210 wraper. The problem I am having is using labview to interface with the RP1210 layer.  The RecieveMessage char*fpchAPIMessage this is the output which is a pointer to a cahracter array.  In this variable I can receive the timestamp of the message but not the message.  The retun showns the correct amount of bytes are aviaable (18 for a 8 byte message) but I can only get the 4 byte timestamp  I think I have to dereference this pointer to view the data.  I am not sure how to fix this. 

  • Tcp data b/w labview and c++

    Hi
     i am trying to establish TCP connection b/w LABVIEW and C++ program. Server is established in C++ while client is implemented in labview.Although connection is successfully establish b/w server and client, both are unable to correctly understand data send/receive among them. Forexample if i want to send an int type send_array from server, i use standard WINSOCK function "send" like that:
    send(AcceptSocket,(char*)send_array,129*4,0);
    but when client in labview receive this array, it shows unexpected values.As a client, I used "simple data client.vi"  with one modification i.e. as sent data size(129*4 bytes) was fixed, only one TCP read was used . 
    Same problem exists if i send data from client to server.
    Kindly help me
    Best Regards
    Solved!
    Go to Solution.

    It's probably an big/little edian problem. If you are using the Flatten/Unflatten from String functions, you can specify which to use.

  • Questions on Saving and mining data with Labview and DIAdem

    Hi,
    I am sampling two signals at 200k sampling rate. I am trying to save the data on harddisk and analyzing the data using DIAdem.
    If I save the data using mesurement file format .tdm and .lvm, the file size will be about 4 Gigabytes for only 10 mins' acquisition. It is very slow to process it.
    I used the software Clampex and pCLAMP(Axon Instruments) before. At the same 200k sampling rate and also acquiring two signals, these programs save the data as .atf format and the size is only 400 MB for 10 mins' acquisition.
    I wonder if there is also a good way to handle this situation using Labview and DIAdem, and how to do it?

    Hi, Jonathan:
    I tried the TDM binary file format. The file size is 800 MB per min acquisition and it will take a long time to just open these files. For my application, I have to take data for several hours. I am looking for a way to reduce the size of files.
    Is there any other type of file format that can reduce the size significantly and can be handled easily?

  • Please Help!!! VIPM won't connect to labview and I need to figure out why

    I am trying to download the Arduino package from the VIPM and they won't seem to connect. I have included a picture of the error and two more of my settings. I am using the student evaluation of the Labview software, but I'm not sure that it is what's causing the problems. Any help would be appreciated, as I would like to set up a nice GUI using labview and an arduino as my DAQ device. I need this for a project for my professors so I am rather desperate to get it up and running.
    Attachments:
    Labview Error.jpg ‏352 KB
    Labview Error II.jpg ‏141 KB
    Labview Error III.jpg ‏108 KB

    No, i tried using you settings and stil not working. i went through every combination of the four items I have on the machine and export list. Still nothing, do you think that its that i am using the student version?
    Attachments:
    New Labview settings, not working.jpg ‏123 KB
    New Labview settings, not working.png ‏267 KB

  • Can I use a camera for application in Labview and VBAI at the same time ?

    Dear all,
    I'm trying to save an AVI file with Labview and make an image process with VBAI at the same time, in one machine.
    The error : "Camera already in use" displayed.
    My Camera is a GIGE and I work with Imaqdx. I've test the multicast mode but it only operate with several machines.
    How can I do this ?
    Thank's to help me,
    Yoann B

    I'm not necessarily saying that.  It's been a while since I've used VBAI, so I don't remember all of the capabilities, but if VBAI can do the inspection and recording at the same time, you should be fine.
    The trick is that only one program can access the camera at the same time.  That application reserves the camera, thus making it unavailable to others.
    Chris
    Certified LabVIEW Architect
    Certified TestStand Architect

  • Tdms-files: Is it possible to prevent LabVIEW and DIAdem from creating .tdms_index files?

    Hello,
    is it possible to prevent LabVIEW and DIAdem from creating .tdms_index files when opening/creating/editing a .tdms file?
    I think I have no benefit from the .tdms_index files because our applications create a lot of little .tdms-files (repeat measurements). With the additional .tdms_index files we have unnecessary memory consumption and it takes longer for Windows to open the containing folder. Also it´s confusing when searching for a certain file.
    Best Regards
    Daniel
    Solved!
    Go to Solution.

    Hi Baui,
    I'm afraid there's a direct way to disable creating .tdms_index file now from LabVIEW and DIAdem. You can use TDMS Advacend API in LabVIEW, which doesn't create any index file, or you can just make some simple programming and delete the .tdms_index file after closing the TDMS file. 
    This is a request for a long time, we'll consider to add this feature for TDMS in future releases.
    Yongqing Ye
    NI R&D

  • Problems with Labview and Windows XP with error -214721786​5

    Hello. Im a new beginner in Labview and am having a problem with a error message
    I dont understand. Im running Labview on a pc-logger with windows XP.
    The program is written by a guy on my university, and logs voltage from
    a solar cell panel. He doesnt have the time to check in to it, so Im supposed to
    find out what's wrong.
    The error message is as follows :
    Error -2147217865 occured at Cmd Execute.vi->DB Tools Insert
    Data.vi->Solcelle.vi
    Possible reasons :
    Exception occured in Microsoft OLE DB Provider for ODBC Drivers,
    [MySQL][ODBC 3.51 Driver][mysqld-3.23.38-log]Can't open file :
    'solcelledata.MYD'. (errno: 145). in Rec Create - Command.vi-
    >Cmd Execute.vi->DB Tools Insert Data.vi->Solcelle.vi
    I really hope someone can tell me what's wrong and specifically what to do
    with it, or possibly guide me to someone who could suggest a solution to this
    problem.
    Reguards
    chrisdee

    Hi Chrisdee,
          (.. not to discount what TimoS has suggested, however...) 
    Embedded in the error information you provided:
    ... Can't open file : 'solcelledata.MYD'.
    Sounds like the program needs this file?  Has the program been moved to a new location?
    just a wild guess!
    Cheers
    Message Edited by Dynamik on 10-06-2005 04:53 AM
    When they give imbeciles handicap-parking, I won't have so far to walk!

  • Hi! can any1 pls let me know how to create a look up table in labview and use that in the vi.

    hello !
    i have no idea how to build a lookup table(as v use in microcontroller) in labview and use that in vi.pls help me
    txs
    nitin
    Solved!
    Go to Solution.

    If the lookup table is always going to remain the same (e.g. a character generator or something similar) you can place the values in a 2D array constant on your diagram, with the input value as one column, the equivalent as the other. When you need to perform the lookup you use an index array to return all the values in the "input column", search it using "search 1D array" and use the resulting index number to index the other column's data. If the values may change, then it would probably be best to load an array control with your equivalent values from a file.
    P.M.
    Putnam
    Certified LabVIEW Developer
    Senior Test Engineer
    Currently using LV 6.1-LabVIEW 2012, RT8.5
    LabVIEW Champion

  • Are there any 3rd party LabVIEW and/or TestStand code analysis tools

    I am looking for any 3rd party tools to analyze LabVIEW and/or TestStand code. Looking for tools that will check for memory leaks, timing, and any other code performance problems. I know LabVIEW has the profiler tool, but I am looking for 3rd party tools.

    Hi wbolton,
    I am personally not aware of any 3rd party tools that do the same thing as the Profiler, but I can say that if you'd like to analyze a .VI or .seq file, the most straightforward way to do so would be with the appropriate National Instruments software.
    Regards,
    Dan Richards
    Dan Richards
    Certified LabVIEW Developer

  • Interfacin​g between labview and microcontr​oller using rs 232

    hi my task is to generate a wavefrom of certain frequency and certain duty cycle in labview and feed it to pic18f452 microcontroller and the o/p of microcontroller when connected to CRO should display the same frequency and duty cycle which was fed from labview.
    for that when i am sending decimal data from labview microcontrolle is receiving ascii data for eg 62(decimal) gives 36 and 32 respectively in microcontroller registers and when i use type cast function and convert the decimal data into ascii data and then sending it to uc it gives hex o/p so i am confused that how to solve this problem
    pls guide me
    thanks
    satish

    So your display from the uc is giving you a hex display instead of the ASCII representation? Are you using VISA to send a string to the uc? Is that string being represented as hex instead of ASCII by the microcontroller? I'm confused about what exactly your setup and problem is...

  • Interfacing between labview and microcontroller using rs 232

    hi my task is to generate a wavefrom of certain frequency and certain duty cycle in labview and feed it to pic18f452 microcontroller and the o/p of microcontroller when connected to CRO should display the same frequency and duty cycle which was fed from labview.
    for that when i am sending decimal data from labview microcontrolle is receiving ascii data for eg 62(decimal) gives 36 and 32 respectively in microcontroller registers and when i use type cast function and convert the decimal data into ascii data and then sending it to uc it gives hex o/p so i am confused that how to solve this problem
    pls guide me
    thanks
    satish

    Double post

  • I am new to Labview and was wondering if it is possib

    le to control Labview via an external script? I am trying to automate my testing and want to use a script to send commands that will call my equipment.vi models and have it configure the equipment via GPIB to the test instruments. Thanks in advance - HeidiI am trying to automate my testing and want to use a script to send commands that will call my quipment.vi models and have it configure the equipment via GPIB to the test instruments. This will take out the GUI interface and still allow my model .vi's to control my equipment. - Thanks in advance - Heidi

    le to control Labview via an external script? I am trying to automate my testing and want to use a script to send commands that will call my equipment.vi models and have it configure the equipment via GPIB to the test instruments. Thanks in advance - HeidiHi Heidi.
    Check out this link from Jeffrey Travis
    http://www.jeffreytravis.com/lost/labperl.html
    "LabPerl is a cross-platform API for letting LabVIEW and Perl communicate. It consists of some LabVIEW VIs and 2 Perl modules (.pm) files that allow Perl functions to call LabVIEW VIs and pass data, and viceversa. You should be somewhat familiar with Perl before trying to use LabPerl."
    I do not know if it will do what you want as I never tried it, but it is worth a try.
    PJM
    Got EasyXML?
    JKI.VIPM.EasyXML.OpenG.LAVA.Builder.blog

Maybe you are looking for

  • Regarding: Scheduling error

    HI All. while doing the scheduling aggreement, i got the following error. Therre are no import data available and canot be proccess. Thanks Regards siva

  • Acrobat Reader X : Error using javascript with ProtectedMode on

    Stumped with an issue. I have a PDF with a mouseup event to trigger the PDF to SAVE to a network location and it works fine in v9 but with Reader X and enable Protected Mode turned on it throws the following error: NotAllowedError: Security settings

  • Vendor Line Item (FBL1N) problem

    Hi SAP, How to setting Due on column (Field name: ZFBDT) to be "optional entry" instead of "suppress" it? Where can i find the setting in configuration Txn SPRO? I will give points who helps me. TQ Regards, Nazrul

  • Can't install mavericks on my MacBook Pro mid 2010. Can't detect the HDD.

    Hi all, find it very frustrating trying to install the new OS after the hard drive is not detected. I'm trying a clean install of the Mavericks using an 8Gb usb flash drive. However, when trying to reformat the drive using disk utility and trying to

  • Placing InDesign files vs. eps

    We produce teaching materials where we have to illustrate the page from another document (i.e. "Hand out this page to the students"). Last year we created endless eps files from the InDesign docs, only to create headaches when last minute changes wer