LabVIEW openings with Captronic System, Bangalore location

We have urgent openings with our organization.
Experience : 2-4yrs
Job Description:
NI LabVIEW
LabVIEW Real Time & FPGA Programming
Data Acquisition System
Project experience using NI cRIO/ NI PXI
Atleast 3 projects on LabVIEW.
Industries to cater - Defense, Aerospace, Automotive, Manufacturing, Nuclear.
Company: Captronic Systems.
Job Location : Bangalore.
Job type: permanent
If Interested send your updated resume to [email protected]  With your current CTC, expected CTC and Notice period. or feel free to call on 9738427980

Dear Sir/ Madam,
I am writing in response to your job notification for LABVIEW
I am a B.E ECE with an aggregate of 7.73% marks.
- I have good knowledge of programming languages like C, C++, Embedded C,Assembly and Basics of LABVIEW.
- I’m compatible on working various operating systems like Linux, windows, etc.
- I have also done 6 months internship from Electro System Associates(ESA) Bangalore.
Also I have an Experience in the Field of Testing and Measuring Instruments.
I am from Electronics background .Please provide me an opportunity .
Some of my personal qualities which you may find useful for this role are:
- Ability to learn quickly coupled with innovative ideas for problem solving
- Ability to work in a team with strong communication skills
- Hardworking and sincere towards work with an ability to take directions
Please find my detailed CV for your consideration. If you need any more details, please let me know.
Thanking you for your time and looking forward to hear from you.
Sincerely
Gopinath.s
Ph:9535569115

Similar Messages

  • LabVIEW openings with Captronic System, Pune location

    We have urgent openings with our organization.
    Experience : 2-4yrs
    Mandatory Skills:
    Technically sound, Handled atleast 3 LabVIEW based project, exposure to NI HW  
    CLAD certification atleast.
    CLD Preffered
    Experience in configuring system -  ( Selecting appropriate hardware, estimating man days for software, integration, installation & Commissioning)
    Candidate should be comfortable in travelling.
    Industries to cater - Defense, Aerospace, Automotive, Manufacturing, Nuclear.
    Company: Captronic Systems.
    Job Location : Pune.
    Job Role: Engineer
    Job type: permanent
    If Interested send your updated resume to [email protected]  With your current CTC, expected CTC and Notice period. or feel free to call on 09738427980

    Dear Sir/ Madam,
    I am writing in response to your job notification for LABVIEW
    I am a B.E ECE with an aggregate of 7.73% marks.
    - I have good knowledge of programming languages like C, C++, Embedded C,Assembly and Basics of LABVIEW.
    - I’m compatible on working various operating systems like Linux, windows, etc.
    - I have also done 6 months internship from Electro System Associates(ESA) Bangalore.
    Also I have an Experience in the Field of Testing and Measuring Instruments.
    I am from Electronics background .Please provide me an opportunity .
    Some of my personal qualities which you may find useful for this role are:
    - Ability to learn quickly coupled with innovative ideas for problem solving
    - Ability to work in a team with strong communication skills
    - Hardworking and sincere towards work with an ability to take directions
    Please find my detailed CV for your consideration. If you need any more details, please let me know.
    Thanking you for your time and looking forward to hear from you.
    Sincerely
    Gopinath.s
    Ph:9535569115

  • Urgent openings with Captronic Systems, Bangalore Location.

    *Educational Qualification :
    B.E/B.Tech (EEE, ECE, IC, E&I)
    *Experience :
    6Months - 4 years experience
    *Job Role :
    1. Co-ordination with clients
    2. System requirements gathering
    3. Designing and development of software architecture
    4. Project related document preparation
    5. Support and troubleshooting
    *Mandatory Skills:
    1.       Good knowledge about basic electronics.
    2.       Labview knowledge .
    3.       Should have knowledge about NI hardware
    *Desired Skills :
    1.       Knowledge in aerospace/ aircraft/ defense/ manufacturing domain
    2.       Should have worked on shared libraries in LabVIEW
    3.       Good to have CLAD/ CLD certification
    4.       LabVIEW RT and FPGA Knowledge
    5.       TCP/IP, RS232/RS422 protocol knowledge
    6.       4. NI DAQ hardware knowledge
    Soft Skills : ( Communication/ Languages/ Negotiation/ Presentation, etc )
    1. Should be able to handle customers
    2. Should have excellent Logical and Analytical problem solving approach
    3. Must have excellent communications, organizational skills, presentation skills and must be a team player
    Company: Captronic Systems.
    Job Location : Bangalore.
    Job type: permanent
    Industries to cater - Defense, Aerospace, Automotive, Manufacturing, Nuclear.
    If Interested send your updated resume to [email protected]  With your current CTC, expected CTC and Notice period. 
    Thanks & Regards,
    HR Team

    Dear Sir/ Madam,
    I am writing in response to your job notification for LABVIEW
    I am a B.E ECE with an aggregate of 7.73% marks.
    - I have good knowledge of programming languages like C, C++, Embedded C,Assembly and Basics of LABVIEW.
    - I’m compatible on working various operating systems like Linux, windows, etc.
    - I have also done 6 months internship from Electro System Associates(ESA) Bangalore.
    Also I have an Experience in the Field of Testing and Measuring Instruments.
    I am from Electronics background .Please provide me an opportunity .
    Some of my personal qualities which you may find useful for this role are:
    - Ability to learn quickly coupled with innovative ideas for problem solving
    - Ability to work in a team with strong communication skills
    - Hardworking and sincere towards work with an ability to take directions
    Please find my detailed CV for your consideration. If you need any more details, please let me know.
    Thanking you for your time and looking forward to hear from you.
    Sincerely
    Gopinath.s
    Ph:9535569115

  • NI LabVIEW, SCADA opening with Captronic Systems, Bangalore Location.

    We have urgent openings with our organization.
    Experience : 3+yrs
    Qualification : BE/Btech/ME/MSc ( Instrumentation, Electronics, Electrical, Mechatronics)
    Mandatory Skills:
    Technically sound
    Handled atleast 5 LabVIEW based project.
    exposure to NI HW  and NI LabVIEW, SCADA project
    Knowledge OPC concepts, Networking concepts must
     Industries to cater - Defense, Aerospace, Automotive, Manufacturing, Nuclear.
    Company: Captronic Systems.
    Job Role: Project Lead
    Job Location : Bangalore.
    Job type: permanent
    If Interested send your updated resume to [email protected]  With your current CTC, expected CTC and Notice period. or feel free to call on 09738427980
    Thanks & Best Regards,
    Niharika

    Dear Sir/ Madam,
    I am writing in response to your job notification for LABVIEW
    I am a B.E ECE with an aggregate of 7.73% marks.
    - I have good knowledge of programming languages like C, C++, Embedded C,Assembly and Basics of LABVIEW.
    - I’m compatible on working various operating systems like Linux, windows, etc.
    - I have also done 6 months internship from Electro System Associates(ESA) Bangalore.
    Also I have an Experience in the Field of Testing and Measuring Instruments.
    I am from Electronics background .Please provide me an opportunity .
    Some of my personal qualities which you may find useful for this role are:
    - Ability to learn quickly coupled with innovative ideas for problem solving
    - Ability to work in a team with strong communication skills
    - Hardworking and sincere towards work with an ability to take directions
    Please find my detailed CV for your consideration. If you need any more details, please let me know.
    Thanking you for your time and looking forward to hear from you.
    Sincerely
    Gopinath.s
    Ph:9535569115

  • Calling LabVIEW professionals!!!! Job openings at Captronic Systems Pvt. Ltd!!!

    Captronic Systems Pvt.Ltd (CSPL) Largest alliance member of National Instrument in India and an ISO 9001:2000 certified company has massive expansion plans. As a part of the plan CSPL is looking for experienced LabVIEW professionals for abroad projects for onsite work in US and Germany.
    Interested candidates can apply to [email protected]
    Please do not apply by replying to this e-mail.
    CSPL is also setting up a huge infrastructure in Marathahalli, Bangalore.

    Dear Sidharth,
    This mail id is couldn't be send details from my side, do you have another e-mail id.
    It'll came like this,
                Delivery to the following recipient failed permanently:
                Technical details of permanent failure:
                DNS Error: Address resolution of nexusengiconsults.com. failed: Domain name not found
    Thanks & Regards,
    SABARI SARAVANAN M
    Certified LabVIEW Associate Developer

  • LabVIEW openings with H1 Sponsorshi​p

        Hi All,
    Does anybody know about companies which are willing to sponsor H1 and have LabVIEW requirement
    Thanks,
    Vilas G

    Electronic Test Engineer, mixed digital/analog
    Company: NAPCO SECURITY SYSTEMS, INC.
    Location: US-NY-Suffolk
    Job Type: Employee-Full Time
    Required Education:  BSEE or BSEET or equivalent experience
    Required Experience:  1 year minimum
    Experience Details
    Have a minimum of 1 year in the design and development of electronic production test equipment.  Must have familiarity with Microprocessor, Digital, Analog, and Wireless hardware circuitry.
    Skills/Abilities
    Experience in electronic test design, in-circuit testers, selection and specification of components required for fixture creation.
    C Programming knowledge a plus.
    Familiarity with National Instruments software is a plus. Company will train a suitable applicant in National Instruments Labview.
    Able to document test procedures.
    Be able to make a prototype of test circuits.
    Be a problem solver.
    Work with minimal supervision.
    Have a hands-on, can-do attitude.
    Job Description and Responsibilities:
    Job will entail design, development, programming, debug, and modification of test fixtures including planning to insure timely delivery and commissioning to production.
    Assist production management with test issues.
    Review all aspects of test platforms appropriate for the company's applications, including selection decisions.
    Provide cost and schedule estimates for subsequent approval.
    Report status to department manager.
    Follow test requirements from the product designer.
    Document design quickly and with high accuracy.
    Provide test liaison support with subcontractors as necessary.
    May involve occasional travel.
    Contact
    Qualified candidates send resume/letter with salary requirements to:
                    Email: [email protected]
                    Fax: (516)789-8176
                    MAIL                333 Bayview Avenue
                                    Amityville, New York 11701
    Keywords:  TEST ENGINEER, ENGINEERING, TEST, TECHNICIAN, JR. ENGINEER, ELECTRONICS

  • LabVIEW Openings in Bangalore, India

    Captronic System Pvt. Ltd., a Select Alliance Partner of National Instruments, specializes in the design and development of custom automated test, control and acquisition systems for R&D, design validation and production testing.
    Captronic Systems is looking Electrical/Electronics/Instrumentation Engineers with LabVIEW experience. In addition to excellent package, we also sponsor our employees for certifications from National Instruments.
    Please visit the careers section of our website for more details and send your resumes to [email protected] or [email protected] .

    Dear madam.
                    This is sivaramkumar from Bangalore....i have Completed B.E in Electronics & Instrumentation eng....and i have 1 year Experiance in Automation Projects..Now i am Working under Lab VIEW develobment Data Acquistion from NI cards..I am suite for your recruit..i have enclose  my resume in this forum..you can reach me as soon as....
    Attachments:
    Sivaramkumar LabVIEW.doc ‏59 KB

  • Error from labview 6.1 with the system windows 7

    I use Labview 6.1 vi to control a Tektronic oscilloscope and a BNC universal pulse generator via GPIB-USP connection. The vi worked very well with the system windows XP. The system was changed to Windows 7. Then one error message (Trigger signal is not recognized. Check the connection between 'Trigger out' and 'Aux in') comes whenever I start to run vi. The connection between 'Trigger out' and 'Aux in' works under mannual mode, so it is really ok.
    Could the compatibility between Labview 6.1 and windows 7 be the reason? If yes, are there tricks to use Labview 6.1 on windows 7?  Thanks. 
    Solved!
    Go to Solution.

    I do not know coding with Labview actually.....
    I set the pulse generator to mannual mode and send pulsing signal to scope. The signal was received well and displayed by the scope. It means the connection between 'Trigger out' and 'Aux in' is ok.
    The record of NI I/O interface is attached when the error message comes.
    Thanks.
    Attachments:
    Capture.txt ‏85 KB

  • How to export All computer list with operating system from AD and all attributes like disable or enable and OU location also?

    how to export All computer list with operating system from AD and all attributes like disable or enable and OU location also?
    I have tried with dsquery below but status is not showing there.
    dsquery * -filter "(objectCategory=computer)" -attr name operatingSystem

    last logon user name - not really stored (or lined) with computer object.  However, you can get this info during the logon process or from the computer.  Here is method:
    http://portal.sivarajan.com/2010/07/user-profile-and-os-info-powershell.html
    Santhosh Sivarajan | Houston, TX | www.sivarajan.com
    ITIL,MCITP,MCTS,MCSE (W2K3/W2K/NT4),MCSA(W2K3/W2K/MSG),Network+,CCNA
    Windows Server 2012 Book - Migrating from 2008 to Windows Server 2012
    Blogs: Blogs
    Twitter: Twitter
    LinkedIn: LinkedIn
    Facebook: Facebook
    Microsoft Virtual Academy:
    Microsoft Virtual Academy
    This posting is provided AS IS with no warranties, and confers no rights.

  • New LabHSM Toolkit - Agile development of complex event-driven maintainable LabVIEW applications with active objects / actors based on a universal Hierarchical State Machine / statechart template.

    Dear Fellow LabVIEW programmers:
    Most of the systems you deal with are reactive. It means that their
    primary function is constant interaction with their environment by
    sending and receiving events. But most likely, they can have something
    happening inside them too, even when they are not processing messages
    received from outside. So, such systems have to continuosly react to
    external and internal stimuli. Right? Moreover, most likely, they
    consist of subsystems that are reactive too and, in turn, can have
    their own "life", to an extent independent from other parts (with
    which they still communicate, of course). Reactive (event-driven)
    systems are more naturally modeled with active objects. So, why then
    should we try to model and code them with GOOP and its passive
    ("dead"!) objects?
    "Flat" State Machines have been known for decades to have severe
    limitations. It's been more than 20 years since Dr. Harel invented
    Hierarchical State Machines (statecharts) to fight those limitations.
    Then why does NI still tout the same old good Moore FSM as the
    ultimate tool for event-driven programming in LabVIEW in its $995
    State Diagram KIt?
    The LabHSM toolkit we are happy to present, makes it possible to
    easily create and then maintain complex event-driven applications in
    LabVIEW as a collection of HSM-driven active object VIs using a higher
    level of abstraction and agile software development methodologies.
    These active object VIs are created based on a universal Hierarchical
    State Machine ( HSM or statechart ) template. So. all your code looks
    similar regardless of its functionality!
    We all love just jump to code, right? However, to be good boys, we
    need to do design first. Then implement it in code. If the logic is
    modified we need to redo the design first and then redo the code. When
    using LabHSM where behavior information is abstracted into a separate
    HSM data file editable with a supplied editor, there is no need for
    coding separate from design any more. The modified behavior becomes
    code automatically as soon as the HSM file is saved. Design is code!
    The implementation basically follows Dr. Samek's Quantum Programming
    paradigm. (see http://www.quantum-leaps.com). However, as already
    mentioned, LabHSM stores the behavior information in a file separate
    from the code itself. It also adds state dependent priorities to
    events, a separate queue for public events/messages, and, of course,
    some LabVIEW specific code like capturing front panel user events and
    putting them into the private Events queue. Communication and
    instantiation functions are also rather specific for LabVIEW.
    It is available for UNLIMITED PERIOD trial. Please visit
    http://www.labhsm.com for details and download. The site also contains
    references which you may want to check to learn more about
    hierarchical state machines and active object computing.
    Since this is our debut we will appreciate any comments and
    suggestions. Our contact information is available on our site, of
    course.
    Have a G'day!

    Symtx is currently hiring the following position. Please contact me if interested.
    Amy Cable
    Symtx, HR
    [email protected]
    Symtx, the leading supplier of functional test equipment, hires the brightest & most talented engineering professionals to design & manufacture complex custom electronic systems for advanced technology leaders in the defense, aerospace, communications, medical, transportation & semiconductor industries. Symtx’ challenging & dynamic work environment seeks to fill openings with highly qualified electronic engineering design professionals.The ideal candidate will be responsible for defining the requirements, software design and code development, and integration of test control software for custom functional test systems. Candidate should be familiar with data acquisition concepts, instrument control, complex test, measurement and calibration algorithm development and definition and implementation of control interfaces to hardware. Prefer familiarity with instrument control via GPIB, VXI, MXI, RS-232 desirable. Requires BS/MSEE and 3 -7+ yrs of experience in one or several of the following test applications in a Windows NT/2000/XP environment using Labwindows CVI, TestStand, Labview, Visual Basic, C++ and knowledge of RF systems is a plus. Job responsibilities will include software design, development, integration, team leadership, and interfacing with customers( includes PDR’s & CDR’s).

  • Can we call LabVIEW VI's (saved at shared location say server)from two different test stations?

    Hello All,
    My question is related to calling and execution of LabVIEW Vis  from two or more different teststation(Test System) using NI TestStand.
    Following are some definitions to understand the question better
    A Test Station:is a independent sytem.different instruments(Multimeter,Function generator etc) are connected to this Station.Teststaion using NI TestStand for Test managment.
    A LabVIEW :LabVIEW vis are saved at share location(server).These vis are responsible for communicating with different instruments connected to TestStation.
    Execution:TestStand calls these Vis in sequene to perform particular test.
    My query is to know ....Can we call and execute shared labVIEW vis from two or more TestStation simulatneously and cummunicate with connected instrument on each teststation.
    Is there any possiblity of conflict as using same vis but on different station?
    My concern is to avoid duplicacy of similar vis.Is there any better option to implement the same concern?
    Thanks in advance
    Regards:
    Vaibhav Kanchan
    Sr. Engineer
    NI Certified LabVIEW Developer(CLD)
    NI Certified TestStand Developer(CTD}

    I suggest you to try adding the shared vi to the labview project(.lvproj) running in same or different stations which is connected to the instrument. Adding the vi to a project will open it in the project instance instead of default application instance. Hence there won't be any conflict in execution.
    Anand kumar SP
    Senior Project Engineer
    Soliton Technologies Pvt Ltd

  • Crystal Reports XI R2 SP 6 - Issue with setting Data Source Location

    Hello,
      After some initial difficulty instally CR XI R2 with SP 6 on a windows XP machine (see thread Error on installation of CR XI R2 SP6), the Crystal Reports environment seemed fine, however, when I tried resetting the datasource location on an ODBC datasource between a development and production server, I get the message 'Some Tables could not be replaced as no match was found....'   The tables in the two databases are identical so that isn't the issue.
    Here is some additional information
    The issue seems related only to DSN's that point to a progress database.  I am able to reset datasource locations for DSN's that use the SQL server driver and also for those that use the XML CR ODBC XML Driver 5.0.  I am not able to reset the datasource locations on the DSN's that use a Progress Open Edge 10.1 DB  driver.
    I can create a new report using the DSN for the Progress Driver and add tables, but the table names are coming up as an alias - i.e. if I add a table called PM_Plant, the table added to the report is PM_Plant1.
    I also found I can go into existing reports, rename the tables in the database expert to be an alias (appending 1 to the end of the table name), then I am able to repoint them using the datasource location screen. 
    So it looks like there is a potential work around to the situation, but I didn't run across any information that we should need to do that. 
    Any recommendations how to fix the issue?  
    Thanks,

    Hi Don,
    The reports were created with CR XI R1 on my PC  initially and the progress drivers have not changed since.   The reports were deployed to a server and I pulled them back to my PC to test out any changes after the CR XI R2 SP 6 upgrade.  (so there is really only one machine involved, the one that had the upgrade). 
    I did look at the settings for verifying and tried playing around with those and also with verifying the database but that didn't make any difference.
    I wasn't quite sure which registry keys to look at or what the values should be so wasn't able to pursue that option. 
    All the tables in the progress database use underscores as part of the table name (i.e. PM_Plant, PM_Company), do you think the upgrade to SP6 means that the underscore is now a reserved character and that is why the tables are getting aliased?  If so, do you know how to change the alias settings or the list of characters that are reserved?
    Just an FYI, I had to downgrade back to CR XI R1 at this point to get work done.   If time allows, I'll retry the upgrade in about 5-7 weeks.  I discussed the issue with a system admininstrator and we willl try removing the progress drivers and DSN's prior to trying an upgrade again to see if that makes a difference.  I'll also make sure to keep track of all Report Options and Options and also registry keys to see what changes.
    Thanks

  • LabVIEW VI with Report Generation Toolkit elements in a TestStand sequence does not run with a LabVIEW 8.5 Run-Time Engine

    Hi all,
    I am using LabVIEW 8.5.1 and TestStand 4.1. I have done a TestStand sequence with a VI in it, which uses Report Generation Toolkit elements. On my machine I am using LabVIEW and TestStand with a Development System license. On the other machine I am using TestStand with a Base Deployment license and I have chosen the LabVIEW 8.5 Run-Time Engine in the Adapter Configuration. Everything is running well except of this VI with Report Generation Toolkit elements. The error message is showing that the VI is not executable. It works well only after I have installed LabVIEW with an Evaluation license and chosen LabVIEW 8.5 Development System in the Adapter Configuration.
    I have found other posts and a document in the KnowledgeBase with a similar problem: http://digital.ni.com/public.nsf/allkb/8A0E6274D9B​D7B1986256F62006AD402?OpenDocument But I am not using EXE files in my sequence, so I don't know how to solve mine. Anybody has an idea?
    Solved!
    Go to Solution.

    Hello guys,
    thank you very much for your answers!
    @Ruediger:
    I tried to follow the instruction for Method 2 in the mentioned document: http://digital.ni.com/public.nsf/allkb/F3DC40A6E3F​3B25B862570AD005D1D3D?OpenDocument, but the steps on my machine are different starting from step 4. After I click "Continue..." in step 3, I dont get a window, the system just makes a new folder with the same VI. 
    To be honest, I am new to LabVIEW and have some difficulties at this time. What I understood from your reply is, that I need to make a LLB-File, where the files from Report Generation Toolkit are in!?
    @GovBob:
    I was following the instruction in the document: http://digital.ni.com/public.nsf/allkb/9E00E7EFE06​35E678625734600779EFE, but it wasnt working. Can you please tell me how I can check if the VI Server is installed and running on the machine?
    I am using LabVIEW 8.5.1 and TestStand 4.1 on my machine, on the deploy machine there is TestStand 4.1.1. The version of my Report Generation Toolkit is 1.1.2.
    Kind regards, Roman

  • LV 8.6 will Not Compile in LV 2010 - Labview 10.0 Development System Has Encountered a Problem and Needs to Close

    I submitted this support request to NI on 8/12/2010.
    When I compile my LV 8.6 app in LV2010 I get this error:
    "LabVIEW 10.0 Development System has encountered a problem and needs to close.  We are sorry for the inconvenience."
    I was told to do a "Mass Compile" of my LV 8.6 app in LV2010...this failed too.
    I was then told to go to each and every vi and "Mass Compile" individually...after about the 50th vi this got old quickly...and it still didn't compile.  I then sent NI tech support "my code".  The good news is my LV 8.6 app didn't compile with LV2010 @ NI.
    My LV 8.6 app compiles and runs great in LV 8.6.  I don't want to be left behind with the newer upgrades and I want to move to LV2010.  I have lots of LV8.6 code to maintain and I really don't have the time to debug all of my apps.
    I was told this will be looked @ in LV2010 SP1.
    One note...back up your LV8.6 data before you move to LV2010.  Once your LV8.6 code is compiled in LV2010 you will not be able to go back to LV8.6.
    I restored all of my LV8.6 code and I'm back working with LV8.6.
    It's a tough call, do I stay in LV8.6 and get left behind?
    Do I bite the bullet and try to debug this mess in LV2010?
    I was told the compiler is completely different in LV2010.  That's great, but one reason I have NI Maintenance Agreement is to keep updated with the latest software.  I can't afford to re-compile LV code every few years.  Like most people, maintaining my Apps with customer's revisions, and modifications is enough work.  I don't want more work!
    I was told LV2010 SP1 would likely appear in May or June of 2011.  I'd hate to break out my old Turbo Pascal apps again...but hey...they still work!  My NI maintenance agreement is due this month too, I guess I'll pay NI one more year, and see if they come up with a solution.  But if NI doesn't fix this LV8.6 compile in LV2010 problem...I don't see any value staying current with LV software.
    I found another Bug with LV2010...you are going to love this one!
    There is a new "LV Update Service".  Perfect!  I like updating my LV software when new patches are available.  When I click "update" the update spins over and over "Checking for New Version".  I have let it run ALL day with no results...just sits and spins over and over.
    OK, I know give NI a break!  Yes, LV2010 has a new compiler...and Yes, I will renew my NI maintenance agreement.  I just want NI to know failing to compile just one LV8.6 app in LV2010 is not a good idea for customer relations.
    Thanks,
    Doug

    For your update service problem
    Unable to Update Current Version of NI Update Service
    Why am I Unable to Update My Version of NI Update Service in Windows Vista or Windows 7?

  • When I click on the tab with a + on it, located next to the active tab a new page does not open. If I click on "New Tab" in the File menu a new tab does not ope

    When I click on the tab with a + on it, located next to the active tab a new page does not open. If I click on "New Tab" in the File menu a new tab does not open.

    Hi jcatx2013, we don't really have enough information on your system to make specific suggestions...
    Could you test in Firefox's Safe Mode? That's a standard diagnostic tool to bypass interference by extensions (and some custom settings). More info: [[Troubleshoot Firefox issues using Safe Mode]].
    You can restart Firefox in Safe Mode using
    Help > Restart with Add-ons Disabled
    In the dialog, click "Start in Safe Mode" (''not'' Reset)
    Any difference?

Maybe you are looking for

  • How to move Calculated Item in 3rd row in pivot  table.

    Hi experts I have calculated one calculated item in Piovt, Now i want to move it as 3rd row, So how can i achieve it. Thanks in advance Regards Frnds

  • Adobe Air + New iPad (iPad 3) retina display, any idea? any one?

    Hi, I have tried countless amount of times to turn it on, I mean, how can I run my app on the new ipad at 2048x1536, it is always scaling up the app content times 2 and if I try to scale down the whole stage >> 1 (or / 2) of course all images looks b

  • I cannot burn anything using this program

    I have read the instructions, I have read the Hot Tips, and I have even saved an image file and nothing. I have checked settings and preferences and wasted years of time trying to use this so called cool program. I am using an external burner and it

  • Random Record Fails

    Hi, Have had my new you view plus box for a fortnight, now. Everything is working fine, apart from every now and again, randomly, when we set a recording to be recorded at a later time, it will record the first three or four minutes then stop recordi

  • How to make two matrix and table into same group in SSRS

    Hi i need to dispaly to dispaly data  matrix and table .  but matrix data on first page and table data on second page. how to achive this . if i give pagebreak for every new instance for matrix, only matrix data is getting dispalyed in one page and o