LABVIEW- REALTIME 8.6.1

Ok. i have had an issue my previous laptop bit the dust and im trying to reinstall the software on my other laptop but the software will not allow me to download the Realtime 8.6.1 and the NIRIO setup always encounters an error. can someone tell me if there is a digital copy that i can download to see if it is just a defective disc..

Go to this link, http://joule.ni.com/nidu/cds/view/p/id/1207/lang/en and down at the bottom there is a link that says, "Evaluation Software Download Page" If you click that link you can download the evaluation exe that you can activate to full version with your serial number.
National Instruments
Applications Engineer

Similar Messages

  • Using Labview realtime module in RTAI

    hello everyone,
    i want to use Labview realtime module in RTAI for real time applications beacuse of it's free source and very good performance. is it possible to do this work?
    if it is, can anyone introduce some same case study or something similar to this?
    Solved!
    Go to Solution.

    amirsaman wrote:
    hello everyone,
    i want to use Labview realtime module in RTAI for real time applications beacuse of it's free source and very good performance. is it possible to do this work?
    if it is, can anyone introduce some same case study or something similar to this?
    I don't think that is possible for anyone outside NI. LabVIEW realtime supports at this time only Windows as development host and as target only National Instruments hardware with specifcally targeted OSes or the Pharlap ETS system on x86 systems with a somewhat specific hardware configuration. Using RTAI as target OS for LabVIEW realtime applications would require first some modifications to the LabVIEW realtime plugin to support this new platform.
    Also none of the LabVIEW realtime files created for either the NI platforms running VxWorks or Pharlap OS, or the Pharlap ETS system woud be possible to get deployed to a RTAI system, as they are not compatible. You would in the first place have to port the whole slew of shared libraries that make up the realtime LabVIEW runtime system on one of these targets to your RTAI system which is basically a completely new LabVIEW target platform that you can only create with quite a bit of effort from the LabVIEW source code. It's not really impossible for NI as most of the LabVIEW code is written quite platform independently but it would be a combination of the compile settings for current LabVIEW realtime, with settings to produce LabVIEW VxWorks realtime targets with some extra Linux settings. Yet it would be by far not trivial and some of the parts are actually hardware specific drivers which have to be ported too, and limit the possibility of what RTAI hardware could be used even further. In short not something that would make any commercial sense to NI as they would have to invest a lot of resources without any possibility to sell extra hardware.
    And hell is freezing up before NI releases LabVIEW source code in any form that would give non-NI employees access to it! 
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Does PXI-8109 Support Labview Realtime 8.5.1?

    I am having trouble installing labview realtime 8.5.1 onto the PXI-8109.  Does this embedded controller support this version? If not, what's the lowest version does it support?
    Thanks,
    Andy

    Hey Andy,
    With the PXI-8109RT you can only use LabVIEW Real Time 2010 or later. You can see this on the product page of the NI PXI-8109RT. The second bullet on the product page talks about this.
    Regards,
    David A.
    National Instruments
    Applications Engineer

  • Comunicacion Lookout Labview Realtime

    Amigos National Instruments,
    Como puedo comunicarme entre lookout y una aplicacion  labview realtime dentro del PLC cFieldPoint?
    Codial Saludo,
    ManuelB
    ¡Resuelto!
    Ir a solución.

    Hola Arturo,
    Gracias por responder y por su tiempo,
    Mira si yo realizo la aplicación utilizando Labview para monitorear y controlar el programa cFieldpoint no tendría problemas porque el intercambio de los datos es fácil y directo.
    Yo también puedo monitorear y controlar la misma aplicación desde lookout a través de el protocolo Datasock, pero tengo que tener abierto  labview como interfase entre los dos Scada, necesito solamente que lookout coloque  los setpoint del proceso.
    Lo que busco es sí se puede a través de este protocolo y otro medio poder controlar el programa que esta corriendo  compilado dentro del cFielpoint directamente desde lookout sin la necesidad de tener corriendo Labview.
    Cordial Saludo,
    Manbe

  • Using Keyboard or Mouse in LabView RealTime

    Hi,
    I would like to know whether keyboard or mouse can be used as input in LabView RealTime. If yes, can anyone explain me how to get the input coming from the keyboard or mouse?
    Thanks

    Hi e_Rik,
    Could you explain what you are trying to do a little further?  Currently the only real-time targets that can have a keyboard or mouse plugged into them is a PXI chassis or a desktop ETS system. 
    The following links also touch on the subject as well.
    http://forums.ni.com/ni/board/message?board.id=170&message.id=147602&requireLogin=False
    http://forums.ni.com/ni/board/message?board.id=170&message.id=149424&requireLogin=False
    http://forums.ni.com/ni/board/message?board.id=180&message.id=27461&requireLogin=False
    I double checked and currently there are no keyboard or mouse VIs that work on real-time targets.  You may be able to get around this by finding a serial keyboard and mouse and using VISA calls.  Hope that helps clarify, and have a good day.
    Brian K.

  • NATIONAL INSTRUMENT​S LABVIEW REALTIME V6.1, NI-488.2 V2.01, CNC CADCAM

    IAR, NATIONAL INSTRUMENTS LABVIEW REALTIME V6.1, NI-488.2 V2.01, CNC CADCAM
    IAR,
    Microwave Design Office 2002, Cadence, OrCAD, Protel, FPGA, VHDL,
    Natinst, Xilinx, Siemens Simatic, Labview, metrowerks codewarrior8
    [2CDs],
    other 20 gigabytes/week software for pc and mac
    send email for catalogue

    Hello,
    Which driver have you on your computer ? You can see them in MAX >> Software. Which is version of ni-visa, ni-488.2 ?
    What kind of protocol do you want to use : gpib, serial, parallel ?
    What ahhpens in AMX when you test your communication ?
    What are error code and error string ?
    Regards,
    Isabelle
    Ingénieur d'applications
    National Instruments France

  • Labview realtime desktop PC : unable to install software

    I have a Labview realtime desktop PC which was running OK until this afternoon.
    I tried to use the Realtime System Replication.  It wasnt able to copy my config because my app was too heavy and ftp was sloooow.
    I used ftp to delete my app from the target PC.
    From this point I wasn't able to work with the target PC.
    At boot time I've got this message:
    ...Transferring control to user program.
    ...Labview RealTime desktop PC boot loader
    ...Copyright …
    ...Searching hd for boot program .. not found.
    ...Using safe mode program
    ...Init network
    ...Device 1 … MAC .. IP
    System State : No software installed
    When I try to maintain the system via measurement explorer, I'm able to modify the network configuration and to reboot the target.
    Measurement explorer displays "Connected - no software installed" in the status bar (as a matter of fact it displays "Connecte - aucun logiciel installe", I'm using a french version). If I try to install software with the dedicated button ("Add/remove software" I guess) I get a message box displaying an error 59
    Thanks in advance
    Nicolas

    Nicolas,
    Is it possible you inadvertently removed a required file when you FTP'd to the target? I get the impression that the host no longer knows what is installed on the target nor can it repair it.
    Within MAX you can create an Uninstall Disk (option 1) or a Format Disk (option 2). Neither are desirable options, granted, but if the Add/Remove software option throws an error, then I suspect your target has been corrupted. Hopefully someone with more knowledge can translate your specific error code....
    Regards,
    Message Edited by mepausle on 12-20-2006 12:38 PM
    Matthew Pausley
    NC State University
    Raleigh,NC

  • Using dll in labview realtime

    Hi to all,
    I would like to know the best way how to open a file DLL in labview.
    I  created this dll with matlab, real time-workshop, nidll.tlc
    after that I have to use these dll in a real time VI, for using that into a cRIO,does it exist a tutorial in order to explain the procedure?
    thank you

    No it is not! As it uses Cygwin to port the Gnu Unix tools so they can run under Windows. Cygwin is a great tool but had always a hard time to run on newer Windows versions than what was released at the time a particular Cygwin version was created.
    The VxWorks versions that NI used for their realtime controllers is very old. There is no hope that someone would go through the trouble of trying to backport the Cygwin bugfixes since that time to this Gnu toolchain, nor has VxWorks any interest in creating a new Gnu toolchain based on modern Cygwin and Gnu tools for older VxWorks versions.
    NI has moved since away from using VxWorks. In fact the only reason they went with VxWorks, was because Pharlap ETS was not compatible with the PPC CPU and at that time the choice in powerful x86 compatible CPUs for embedded applications was VERY small or actually non-existent.
    As you can see Open source observes similar rules as commercial software. Don't spend much time in trying to make old stuff work on new versions. In fact commercial software usually makes a lot more effort to be portable across different versions. In Open Source the general tenor is, I want feature X, that requires GCC Y, which will only work with glibc x.z.v. Don't spend time in trying to make any of these work with older versions too, or update older applications to work with newer OSes etc. If you want Windows 7 or 8 you have to have Cygwin 1.7.something and that will usually require GCC 4.something and a myriad of other dependencies. The gnu toolchain for VxWorks 6.3 which is used on the NI controllers since LabVIEW 8.5 uses GCC 3.4.4.
    Considering that LabVIEW 8.5 was released in 2008 and the VxWorks tools to create the OS for the controllers obviously even quite some time before that, but Windows 7 RTM was only in July 2009, there is not much you can complain about the fact that those tools do not run on Windows 7 or 8.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Labview Realtime IP assign and making install disk...

    Hello...
    1. How can I assign a static IP address to Realtime Target without using MAX and a host machine? 
    2. I want to prepare a real time target install disk for end user. Is there a way to make an install disk for real time target? How can I install my program wihtout deploy it from Labview?
    Thanks...

    It sounds like you want the system replication tools.  Here is a link for that:
    http://digital.ni.com/public.nsf/websearch/444A6A22A6EC50FB86257213004A878C?OpenDocument
    You will still need to have the LabVIEW runtime engine I believe.  I also don't really understand what you mean by not having a host machine?  How exactly would you like to transfer data to the real-time target?
    Brian K.

  • Hardware for LabVIEW Realtime (ETS)

    Hello NG,
    right now we are using two NI-Devices (PCI 5122 and PCI 6251) in an
    Intel based PC with Windows XP as the operating system.
    We would like to switch to a Realtime-System (ETS) using our PCI-devices
    again in an Intel based PC. As I read (and as we also had to realise)the
    hardware requirements are quite strict and it is very hard to figure out
    if some hardware will work in advance.
    So, does anyone have experience with setting up a realtime system (ETS)
    on a standard PC? Moreover, can anybody give some advice which hardware
    (manufacturer and product-id) will work?
    Thanks in advance
    Oliver

    Actually I read all of those documents. First we tried to set up a
    realtime system using RTX (realtime extension for windows), trying to
    get our hardware to work in a realtime environment on top of windows.
    It was really hard to get at least something to work, where something
    means running labview without hardware on one of the several PCs we
    tested. But we didn't get access to any of our NI-devices, where at
    least the 6251 should have worked referring to the specs.
    So, after calling the NI support they suggested using ETS on a separate
    machine instead of using RTX. We then downloaded the programm to check
    several PC for ETS capability. But all we tried got stuck somewhere in
    the testing procedure (they are probably too new and maybe ETS is not a
    friend of AMD )
    So now, we are going to buy a PC for ETS, but after what we experienced
    with RTX and also with ETS so far, we feel that it could be hard to get
    the right PC or PC components. Because of this I'm looking for advice
    regarding hardware (manufacturer, partnumber etc.).

  • Should i run Datasocket server on Labview realtime OS if am using datasocket write operation in a vi which run in LabviewRT

    Hai
    Am new to LabVIEW, I need to develop a VI that aquires data and transfer it via datasocket, this has to be achived in realtime environment(LabVIEW RT). I wanted to know if i need to run datasocket server on labVIEW RT, if i need to publish and subscribe in the VI runing on realtime.
    Thank you in advance for any help
    Arun

    Sorry if this is a duplicate post (my browser is acting up).
    You cannot run the datasocket server on the RT system, but you can run the datasocket VIs/functions. To use datasocket in RT, run the server on a Windows host and use the correct URL in the datasocket functions running on RT (i.e. dstp:///mydata)

  • Labview Realtime stress test

    Hi,
       I need some help.how to perform Labview Real time application level stress test?is there any tookit available?
    So far I know I can use DSM to check CPU load  and memory usage. Beside from that If I use below screen shot toolkits ,those will give me more on code level and  all are each individual VI trace time.
    Any Idea how to perform stress test for RT application level .
    Thank you.

    Stress testing is inherently application dependent. Basically it consists of looking at what your application can do and doing a lot of it.
    Say for example, your application lets multiple remote users establish a connection and log some data. An example of a stress test would be to see how many simultaneous connections it can handle without failing or degrading it performance to an unacceptable degree.
    What is your realtime application doing?
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • How do I set up LabView RealTime ETS on a desktop computer?

    I have been trying to set up the LabVIEW Real-Time 8.0 OS on a desktop computer.  I have read the the "Requirements for a Desktop PC as a LabVIEW Real-Time target and followed the instruction in the installation manual "Using Desktop PCs as RT Targets with the LabVIEW Real-Time Module".
    The problem I have run into is that there is a built in Network card on the motherboard (Intel Pentium 4 processor ) and the boot program is unable to recognize the Intel Pro/100S Network card I have added (PCI slot 1).  The error message is:  "Unable to configure primary network device".  I can not figure out what settings I have to change in the BIOS to get the thing working (BIOS version EV91510A.86A.0444)
    I have done the following:
    - Formatted the drive as FAT32 & used the Desktop PC Format Harddrive Disk
    - Set the Serial Harddrive ATA/IDE Configuration to legacy
    - Disabled Legacy USB Support
    - Disabled onboard & legacy FP Audio
    any help would be appreciated

    I have tried turing off the built in NIC from the BIOS setup but I could not get it to work.  I disabled the Onboard LAN but this did not seem to do anything.  I am not sure what I have to change in the BIOS setup in order to make the PCI network card the primary network device.

  • Experienced Labview Realtime Engineer wanted. Must be UK.

    I am looking for an experienced Labview/ teststand engineer to develop software for our automated hydraulic test equipment. Please ask for job description. Must be able to work in UK.

    I am going finish my M.Sc here in Sweden. I can work for you if you consider me as an option. I don't have any working visa in UK. I am basically from India.

  • Suggest Embedded PC for Labview realtime

    All,
    It appears that I am not going to be able to use a cFP/cRIO for my applications am going to need to migrate (Back) to an embedded PC.
    Previously I have been using windows xp embedded with a labview .exe which has been diabolical to be polite, windows is not a nice embedded environment.
    I am investigating the use of NI LabVIEW Real-Time Deployment License for Desktop PCs and would like to see if anyone has any recommendations.
    My application uses Comms (485/422) to interface with it's world, so built in comm ports are preferred.
    Speed needs to be >800 mhz 0-50 degrees c.
    Advantech have a range that may be suitable but I am interested to see if anyone has actualy successfuly done it before heading down a dead end path.
    Problems tend to be drivers for ethernet or plug in cards
    Thanks
    iTm - Senior Systems Engineer
    uses: LABVIEW 2012 SP1 x86 on Windows 7 x64. cFP, cRIO, PXI-RT

    Hi Timmar,
    Thanks for the detailed post. As you already stated, whenever converting a PC to a LabVIEW Real-Time ETS PC, the biggest thing to watch out for will be compatibility of Ethernet chipsets and processors. Since you don't have the Advantech embedded PC yet, you can check for hardware compatibility by referencing this Knowledge Base article: http://www.ni.com/white-paper/8239/en
    If you do get your hands on any of the embedded PC or if you have a really awesome friend at Advantech, you can run a test program through a USB utility which can test out the hardware compatibility for you: http://digital.ni.com/public.nsf/allkb/9209361E17708D548625744A007FF353
    With these two documents, you can get started on building your own LabVIEW RT PC.
    Aldo A
    Applications Engineer
    National Instruments

Maybe you are looking for

  • Can't get keyboard command to work right

    Hello, I'm trying to get 2 different sets of keys to move a character in a game. "WASD" and the arrow keys. The arrow keys work fine, but I can't get the character to move to the left witht the "A" key after I press the "D" key. Can anyone tell me wh

  • Intermittent Flash Builder Crashes in OSX 10.8.1

    Flash Builder 4.6 has been crashing intermittently since I upgraded to OSX 10.8.1.  Sometimes it will crash after 10 minutes, other times it will remain stable for a couple of hours, but it always crashes eventually.  The crash doesn't appear to be t

  • Export pdf in discoverer viewer

    Hi All I'm using Disco Viewer 10g. I have a report which have 14 columns and i wanted to display only 11, which is fine i can goto the rows and columns option and set the columns to 11, but now when i export it to the .pdf i still see the 14 columns

  • SCCM 2012 Client agent not installing

    Hi, We have some client machines which has Client as "No" in the SCCM console. The ccmsetup.log file of these machines shows repeated entries like: Download Update: 56283664 out of 66797088 bytes transferred. ccmsetup.log file of another machine show

  • ITunes does not see ATV