Labview run time version

My CVI application needs to have the LabVIEW run-time engine installed to run so I would like to programmatically check it is installed at program start.
Now, the question is not simply "how can I retrieve the LV runtime version?", as differently from CVI there may be more than one LVRTE in the system, so I must either check for all RTEs installed or at least discover the latest (and this makes another question come to my mind: may a module developed on a specific LV rersion can be run with a newer RTE? If so, why having more than one RTE installed?)
Thanks to anyone who can help me in this matter,
Proud to use LW/CVI from 3.1 on.
My contributions to the Developer Zone Community
If I have helped you, why not giving me a kudos?
Solved!
Go to Solution.

Hi Roberto,
first of all, LabVIEW RunTime Engine (differently from CVI) is not backwards compatible (as explained here), thus an application requires a RTE version exactly matching the LV development environment one, in order to run properly.
If you need to programmatically check which LV RTE versions are installed on the PC, you could list the folders contained in C:\Program Files\National Instruments\Shared\LabVIEW Run-Time, as a folder for each version exists.
Otherwise, you could access the registry keys from your application checking in HKEY_LOCAL_MACHINE>>SOFTWARE>>National Instruments>>LabVIEW Run-Time for the installed versions.
I hope this suggestions could help!
Bye!
Licia

Similar Messages

  • Can I run two separate versions of the LabVIEW Run-Time Engine on one PC?

    Hello, I am curious if anyone knew if it is possibly to install and use two separate versions of the LabVIEW Run-Time Engine on one PC?  I currently have the 2009 Run-Time Engine installed on one machine and wanted to install the 2011 Run-Time Engine as well. I know that you can run two separate versions of the LabVIEW program on one machine, but what about the Run-Time Engine?
    Thanks!
    Solved!
    Go to Solution.

    I'm guessing this is a bug that NI needs to fix.  I see no reason you shouldn't be able to install the run-time engine of an older version.  I'd be interesed in if it allows you to install the older development environment, which also includes the older run-time engine.  There are some command line switches for NI installers as mentioned here:
    http://digital.ni.com/public.nsf/allkb/C361087EE9F20810862577850073128E
    I wonder if there is a force install option.
    Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
    If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

  • Why do different versions of the LabVIEW Run-Time Engine not compatible?

    LabVIEW Run-Time Engine to become more and more big
    Why do different versions of the LabVIEW Run-Time Engine not compatible?
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview
    Solved!
    Go to Solution.

    jwdz wrote:
    LabVIEW2020 ....... ,it look like?
    You need to express your ideas more clearly. We cannot fill in the blanks and read between the lines if the post has no substance.
    jwdz wrote:
    It will affect the future development of LabVIEW, right?
    What is "it"?
    There are many things that affect the future development of LabVIEW, starting with NI management, all the smart people in LabVIEW development, the economy, the LabVIEW users, etc.
    If you are worried about the increasing size of the distribution, the good news is that the cost of data storage and data transmission has dropped much more dramatically. Even though newer versions are bigger due to great and welcome new features, the improvements in infrastructure have actually made the distribution and storage significantly easier over the years and will continue to do so. Trust me!
    Nobody wants to go back to a LabVIEW version that fits on a floppy disk!
    LabVIEW Champion . Do more with less code and in less time .

  • How to load dynamically String into a VI using LabVIEW Run-time Engine Version 7.0?

    I would like to be able to traduce string into my application using import string method. I create an program with my VI to translate. When I use the import method, I get this error: the VI is locked. WHY ? because it works well in the edit mode but not using LabVIEW Run-time Engine Version 7.0 .

    Hello loup,
    If you call dynamically a VI in your LabVIEW application you must add this VI when you build the .exe file.
    To add this VI, go to the Tab "Source Files" when you build application and click on "Add Dynamic VI..." then chose the VI you call.
    It should solve your problem.
    In the attached file you can found an example of LV program that translate front panel.
    Try to build exe file and add "Languages.vi" as dynamic VI and .txt files as "Support files".
    I test it, it works.
    I hope that this will help you.
    Best Regards,
    Sanaa T
    National Instruments
    Attachments:
    Translation.zip ‏69 KB

  • Error involving Report Generation Toolkit and Labview Run Time Engine

    Developed an application using LabVIEW 6.1 and LabVIEW Report Generation Toolkit for Microsoft Office 1.0.1. From there, tried to build a shared application for use with the LabVIEW Run Time Engine. The Run Time version functions properly until "New Report.vi" is called and then an error is generated, code 7, calling out "Open VI Reference in New Report.vi" could not be found. When building the application, I did include the "NI Reports Support" in the advanced installer options. The machine used for original development and application build is running Windows XP Pro and Office XP. Any suggestions??

    I am having the exact same problem but with LV 6.1 and M/S WORD 2000. It appears that the "New Report.vi" is trying to open "C:\APP.DIR\Word_Open.vi" and "C:\APP.Dir\Word_Open_Document.vi" by reference. The "OFFICE 2000.TXT" says that "_exclsub.llb and _wordsub.llb must be added as support files when building an application or a dynamic link library with the application builder." I added them as Support Files and I copied them to the "C:\TESTER\" where the TESTER.EXE is and I still get ERROR 7 in "NEW REPORT.VI" at VI OPEN REFERENCE.
    Do I need to make a "C:\TESTER\DATA\" sub-dir and put the support files there?
    I am building on MY COMPUTER on F: Drive on a network and transporting files to the real Tester.
    I displayed my App.Property of APP.DI
    R at start up and it is C:\TESTER\ ! How would my application know that "Word_Open.vi" and "Word_Open_Document.vi" are actually inside the _wordsub.llb?
    Any ideas ?
    Greg Klocek

  • Executable not working - Looking for LabVIEW Run-Time Engine

    This has been one of those days.
    I'm trying to create my .exe file to place onto another computer. I've done this before with success. But that was then and this is now.
    I believe I have all the files I need in my LLB, and I believe I did my application distribution correctly and I believe I built the DLL correctly. But when I took the resulting .exe file and placed it on another computer and attempted to run it, it gave me the error message: "Unable to locate LabVIEW Run-Time Engine. Program requires a version 7.1 (or compatible) LabVIEW Run-Time engine. You should have already realized this, you moron."
    Anyone have any idea where I went wrong or what step I might have missed? This has been a crazy, non-stop, massive brain fart of a day and I can't seem to remember what I'm missing here.
    Amateur programmer for over 10 years!

    Hi.
    Whenever you want to use executables or .dll's created with LabVIEW you must make sure that the LabVIEW runtime engine of the SAME version as the LabVIEW version used to create the files, is installed in the target computer.
    There are basically 2 ways to get the run-time engine installed on a computer:
    1. (the one I prefer): Download the correct version of the LabVIEW run-time engine installer from www.ni.com/downloads, or more specifically from
    http://digital.ni.com/softlib.nsf/websearch/369618​104E25B08E86256F54006A4E2F?opendocument&node=13205​0_US
    for the latest one. Once you have the installer for the run-time engine, just install it in the target computer. I prefer this option because the run-time engine is installed independently, so if you then uninstall your program, the run-time engine remains.
    2. Create an installer for your program that includes the run-time engine. To include the run-time engine, when you are creating your application, go to the "installer settings" tab, click on "Advanced" and make sure there is a checkmark on "include LabVIEW run-time engine". This way when you install your program in the target computer, the run-time engine will also be installed.
    Just as a note, any computer with LabVIEW on it, will also have the run-time engine.
    Good luck.
    Alejandro

  • UNABLE TO LOCATE THE THE LABVIEW RUN-TIME ENGINE.LVBROKERAUX71

    UNABLE TO LOCATE THE THE LABVIEW RUN-TIME ENGINE.LVBROKERAUX71 REQUIRES A VERSION 7.1 (OR COMPATIBLE) LABVIEW RUN-TIME ENGINE。PLEASE CONTACT THE VENDOR OF LVBROKERAUX71 TO CORRECT THIS PROBLEM
    Uninstalled DAQ and reinstalled.  MAX still throws an error. 
    Any Isead besides uninstalling 3/4 of my software?
    Merry Christmas!
    Matthew Fitzsimons
    Certified LabVIEW Architect
    LabVIEW 6.1 ... 2013, LVOOP, GOOP, TestStand, DAQ, and Vison

    To clean up your system, you will need to uninstall the LabVIEW 7.1 run-time engine, and the "LVBroker," and the "LVBrokerAux71" components using the MSI Blast utility.  To obtain this utility, please create a service request for phone or e-mail support, and contact one of our Applications Engineers about this issue.  Thank you!

  • Unable to locate the LabVIEW Run-Time engine

    Using LabVIEW 2011, I have built an executable and installer including the LabVIEW Run-Time engine. I built the app on a 32-bit system. I'm deploying it to a Windows7 64-bit system. When I ran the installer, rebooted, then tried to run the app, I got an error messsage stating "Unable to locate LabVIEW Run-Time Engine", stating that the LVRTE 2011 was needed to run the app, and asking if I want to download from NI. I have tried downloading the RTE and re-installing it, but when I try, I get an error message from the installer stating that there is a newer version of the RTE already installed, and the installer exits! I have tried un-installing the application, but have had no luck removing the RTE. Now I'm stuck. The re-installed executable application says it can't find the RTE, and the RTE installer says there's a later version already installed!
    I can't go forward or backwards!
    Prior to running the installer for this app, I had a working LVRTE for 2011, and was running some other executable LabVIEW programs on the target box. However, since this new application had additional components not included in the original install of the RTE, I built the new installer which included the additional components. Once I ran that installer, my problems began.
    In my frustration, I've tried downloading from NI both the 32 and 64-bit versions of the RTE, and installing them. I realize that the app was built on a 32-bit system, so the 32-bit RTE SHOULD have run it fine, but didn't.
    At this point I have removed the 64-bit RTE using the NIUninstaller. I believe I need to completely remove all 32-bit RTE components and start over, but I have not been able to. The 32-bit RTE does not show up in any un-install utilities I've found.
    What could be causing this problem, and how do I get past it??
    Thank you.

    One thing I did discover in my struggles is that the RunTime engine on the target box needs to be based on the environment of the development box. So if you built the app on a 32-bit machine, you would need to install the 32-bit RTE, even on your 64-bit target box.
    The RTE Uninstaller might not show up in the Windows Add/Remove Programs utility. In my case the 64-bit RTE uninstaller showed up, but the 32-bit did not. The NiUninstaller (C:\Program Files\National Instruments\Shared\NIUninstaller) did list both RTEs for uninstalling, but still didn't get me past the problem.
    I was finally only able to get past the problem by doing a system restore to a point in time prior to my changing of the RTE.
    Good luck.
    Dan

  • Teststand error states that a vi failed to load in the Labview Run-Time Engine

    I am getting an error in teststand that states that a vi failed to load in the Labview Run-Time Engine version '14.0.1'
    If I look at the software loaded on my system with the NI Measurement and Automation Explorer I have Labview Run Time engines for version 2009, 2010, 2011, 2012, 2013, & 2014 on my system.
    How do I get this VI to run on this system when it is called by test Stand?
    Thank you

    The RTE 14.0 was loaded as part of my deployment and after I ran this I got an update notice for the F1 patch which I also loaded.
    I do not have labview loaded on this system, only the run time engines from running my deployment.
    When I launch t he teststand sequence, when it calls the labview VI, I get the following error moessage:
    Error: Failed to load VI 'C:\builds\RelayVoltageMeaure.vi' in the LabVIEW Run-Time Engine version '14.0.1'. LabVIEW: The VI is not executable. This error may occur because the VI is either broken or contains a subVI that LabVIEW cannot locate. Select File>>Open to open the VI and verify that you can run it. VI Path: C:\builds\RelayVoltageMeaure.vi[Error Code: -17600, Failed to load a required step's associated module. ]
    I have attached the teststand sequence if this helps.
    Thanks
    Attachments:
    QuantumDigitalBd.seq ‏13 KB

  • Unable to locate labview run time engine (lab view 8.5)

    Hello I have a problem whit the labview 8.5 installer. I have created I project with included a .vi file (a simple panel wich control a serial port, with parameters (baud rate, stop bits, ...)), then I have created an application for this file (.exe) and then the installer (I have included the labview run time engine 8.5). When I run the setup.exe  I have the following error message:
    Unable to locate labview run time engine, the application require a labview run time engine 8.5 or compatible...
    What I'm missing??
    Thanks
    Maurizio

    are there one other reasons why it would not work.  I have asimilar problem.
    I intsalled version 8 of run time engine and acrtivated software.  Now I am trying to run compiled application provided to me by third party.
    When I click on application it says
    Unable to locate LV run time engine
    Test server requires a version 6.0 or compatible LV engine.
    How do I know if the engine I installed and activated is running and is it supposed to be able to execute a program which is expectin rev 6 of the rund engine?

  • Include LabVIEW Run-Time Engine in C# Project Distribution

    I have written a software package in Visual Studio using C# which calls a number of functions from a dll which I have built in LabVIEW. I am now trying to produce an installation program for my C# package but can't quite work out how to include the LabVIEW Run-Time Engine in this installation.
    I am creating the installation program by defining a Visual Studio Deployment Project and I have added my LabVIEW dll to this. However, the dll requires the LabVIEW Run-Time Engine to also be installed on the target PC. I was hoping that there would be a set of files to implement the installation of the LabVIEW Run-Time Engine that I could include in my Visual Studio Deployment Project and do the installation of both my C# code and my LabVIEW dll (inc Engine) in one operation. Is this possible? Or do I need to produce a LabVIEW installation for my dll separately from the C# installation?
    Info:
    Development OS = Windows 2000
    Target OS = Windows XP
    C# Development Environment = Microsoft Visual Studio 2005 V8.0
    LabVIEW Version = 8.5
    Also, I am using the Order Analysis Toolkit and noticed that there seemed to be an 'Order Analysis Run-Time Engine' installed on my PC. Do I need this too?
    Thanks for any help.
    CAS

    Hi CAS,
    One way of automating the installation of the LabVIEW run-time engine is to use commands in a batch file (*.bat). These commands would be executed automatically at the same time as your distribution installer to install LVRT with your C# application. For more information on command line options, have a look at this KB. I don't have so much knowledge of C# distributions, though, so there may be a better way to approach this that someone else in the community could advise you on.
    With regard to the order analysis toolkit, you will also need this runtime engine installed. A point to note, though, is that the toolkit requires a run-time licence to be deployed in this fashion. It is now part of the Sound and Vibration Measurement Suite and needs to be licenced accordingly.
    I hope this helps!
    Best regards,
    Tom
    Applications Engineering, NI UK

  • NI-LabVIEW run-time engine interop 2010 failed to install

    Hi,
    While installing Labview 2010 (32 bit) I got an error message:
    NI-LabVIEW run-time engine interop 2010 installation has failed with the following error:
    Error 1935. .... (see the .ppt for screenshot if interested)... HRESULT 0x8002802F
    I googled HRESULT 0x8002802F and found a page that said that this error is usually b/c of a missing/corrupt entry in the registry: file %windir%\system32\mscoree.dll, and that "repairing the highest version of the .NET Framework on the system will correct any problems resulting from this error."
    I have verified that mscoree.dll is not present, and I don't have the .NET Framework installed on my system. SO, I have the following questions:
    1) do you concur with the advice given on the page referenced re: the reason for the error;
    2) If so, should I install .NET Framework, and what do I then need to do in LabVIEW to tell it that the .dll is now present?
    3) If your opinion is other, what do you advise?
    Cheers
    Attachments:
    Labview Installation error.ppt ‏227 KB

    Hi Luke, 
    After doing some research, there are two possible solutions.  
    1) According to a KB, it could be your antivirus. You may want to try to turn off any spyware blocking software such as Ad-Aware, Norton, etc and try the installation again. 
    2) Another customer had the same error, and they got it working by installing .NET 3.5 from Microsoft's website and then installing LabVIEW again.
    Hope one of those options work for you!

  • System Error 998 While loading the Labview Run-Time Engine

    Hello.
    I have a DLL made with LV 7.1 I run the dll using a C compiler and works great in WINXP, but cannot run in Win2K. Error is:
    "System error 998 while loading the Labview Run-Time Engin(c:\program
    files\National Instruments\Shared\Labview Run-Time\7.1\\lvrt.dll)
    READVOLTAGE requires a version 7.1 (or compatible) Labview Runtime
    Engine. Please contact the vendor of READVOLTAGE to correct this
    problem"
    READVOLTAGE is my function inside the dll. The runtime is already
    installed. I tried it in another WINXP running machine and works fine.

    This is actually a Microsoft bug with statically loaded DLLs. There are a couple of workarounds for it, and I have included two links below to posts that address this issue:
    Not found error message from LabVIEW runtime when called from VC++ with statically linked MFC
    I get error 998 when calling a LabVIEW buildt DLL from MSVC++
    Kind Regards,
    E. Sulzer
    Applications Engineer
    National Instruments

  • MAX giving error - Unable to locate Labview run-time engine

    I have LV 7.1 and 8.5.1 installed on a WinXP pc. No problems until now.
    I installed some support software for a LabJack  interface, which required LV version 6.1 run-time, so I let it install that.
    I now get the error whenever I run MAX:
    "Unable to locate the Labview run-time engine. LVBrokerAux71 requires a version 7.1 (or compatible) Labview run-time engine...."
    After closing the error boxes, MAX seems to work fine. Both versions of Labview also work. I uninstalled run-time engine 6.1 and re-installed version 8.5.1, but that made no difference. I tried to install run-time version 7.1 from the msi file but it would not let me because a later version of the run-time is installed.
    What is LV Broker? Why does it not accept version 8.5.1 run-time engine? Is it possible to have 2 versions of the run-time engine installed, and if so, how?

    Dear CDancer
    Thank you for contacting NI. First of all, you can have as many versions of LabVIEW run time engines you want loaded on your computer without a problem. LV Broker is installed by all drivers that uses LabVIEW testpanels like DAQmx does. In your case it seems that the LV Broker installation is corrupted or has failed. This can be rectified by overwriting the files in the specified directory listed below:
    C:\Program Files\National Instruments\Shared\LabVIEW Broker
    Your directory should look like the screenshot I have attached; labelled LV Broker Directory View
    I have attached a ZIP File that will replace the LV Broker directory. Please try replacing your files with these if different to the screenshot and let me know how you get on. Many thanks.
    Many thanks for using the NI forums and I look forward to your reply.
    Kind regards
    David
    Applications Engineer
    National Instruments UK
    Attachments:
    LV Broker Directory View.JPG ‏57 KB
    LV Broker.zip ‏413 KB

  • Error -17600 when switching from LabVIEW Development System to LabVIEW Run-Time Engine in Adapter Configuration

    I receive an error message (code -17600) while loading my test sequence after switching from LabVIEW Development System (2009 f3) to LabVIEW Run-TIme Engine using the Adapter Configuration.
    ErrorCode: -17600,
    Failed to load a required step's associated module.
    LabVIEW Run-Time Engine version 9.0.1f3.
    When I switch back to the LV development system, everything is OK, and the sequence loads and runs perfectly.
    My TestStand Engine Version is 2012 f1 (5.0.0.262).
    I'd appreciate any help on this issue.
    Roman

    Hi Roman,
    There are a couple of things you can try:
    1) Determine if the LabVIEW RunTime Engine is corrupted in some way. Create a new simple VI with no sub-VIs, using the same LabVIEW Development system you used for mass-compiling the VIs. Create a TestStand step that calls this VI and ensure it runs correctly. Now switch your LabVIEW adapter to use the RuntimeEngine and choose the "Auto detect using VI version" option.
    Check if the simple VI is loadable and runs without errors in TestStand.
    If the step generates the same error, you should try a re-install of the LabVIEW development system.
    If not, its most likely that there is some VI you are using that is not loadable in the LabVIEW Runtime Engine because:
    1) Some sub-VI is still not saved in the right version or bitness. Open the VI heirarchy of the top-level VI that you are calling from TestStand and examine the paths of all the sub-VIs to check if they were in the folder you masscompiled and re-save any that are outside this directory.
    Also, when you try to close the top level VI, do you get a prompt to save any unsaved files? If so, they could be the sub-VIs that are not saved in the right version. Save all of them.
    Check if you are loading any VIs programatically and if these are compiled and saved in the right version as well.
    2) There is some feature you are using in your LabVIEW code that is not supported in the LabVIEW RunTime Engine. To check this, add your top-level VI to a LabVIEW project and create a new build specification and create a new executable from this VI.
        Right-click "Build Specifications" and choose "New->Application(EXE)".
        In the Application Properties window, select Source Files and choose the top level VI as the start-up VI.
        Save the properties.
        Right-click on the newly created build specification and choose Build.
    Run this executable (it will be run using the LabVIEW RunTime) and check if the VI has a broken arrow indicating that it cannot be loaded and run in the LabVIEW Runtime Engine.
    You might need to examine your code and find the feature which is not supported in the LabVIEW RunTime and find an alternative.
    Another thing i forgot to mention the last time around is if you are using 64-bit LabVIEW with 32-bit TestStand, then executing code using LabVIEW RTE from TestStand will not work since the 64-bit LabVIEW RTE dll cannot be loaded by the 32-bit TestStand process.
    If none of the above steps resolve the issue, consider sharing your LabVIEW code so i can take a look.
    Regards,
    TRJ