Lenovo ix4-300d and 4 Hd 6 tb red

Hi first of all sorry for my english, 
I have 4 Nas ix4-300d,
3 with 4 green 3 tb Hd they work perfectly never have any problem in 3 year. I work in raid 0 because
I duplicate the files in other HH and I want the maximum of space available.
the fourt one I bought 3 days ago and I try to install 4 6Tb red wd inside it in Raid0 here is the problem...
I can't create shares becouse of this message :
"The selected function is not available due to the state of the pools"
So I look on the internet and see that maybe I can't work in raid0 if the disk is bigger than 4 TB (CRAP)
then I try to put Raid 5 ( the only I can choose beside Raid 10 )  but in 36 Hours the data recostruction
is only 19 %     with 0 files on it.......................
Can someone Help me please?
Can someone give me some advise?
Did you know a Nas that work in Raid0 with 6tb and 8 tb disk?
Ty in advance.

Hello Nico84
1.  The ix4-300d will probably be able to use 6 TB HDD's if only 2-3 were installed and depending on the protection mode( 2x 6TB disks RAID 0, 3x 6TB disks RAID 5).  However the limitation your are running into is that the the ix4-300d's Marvell Armada XP 1.3GHz MV78230 processor is only 32 bit and has the 16 TB ceiling.  
2.  The ix2-dl and px class devices can officially support 6TB HDD's in RAID 0 or NONE. 
3.  Please check with these retailers/resellers about lenovoEMC devices in your region.  Where to Buy
4.  With any 32 bit system the capacity limit for a volume is 16 TB.  With the ix4-300d the max supported is 4x 5TB disks in RAID 5,  this would roughly yield a 15 TB volume.  
What you are attempting with the 4x 6TB HDD's in RAID 5 would roughly yield a 18 TB volume, which is above the 16 TB volume ceiliing for the unit's processor.
Again using 3x 6TB HDD's should theoretically work in RAID 5 and yield about a 12TB volume.  If you were to use just 2x 6TB HDD you should theoretically be able to have a 12TB RAID 0 array. Both of which would be under the 16 TB cap.  
If you are fully intending on using 4x 6TB or larger disks, then a px class unit will need to be used. 
I hope this better explains the situation you are having.
LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
US and Canada: https://lenovo-na-en.custhelp.com/
Latin America and Mexico: https://lenovo-la-es.custhelp.com/
EU: https://lenovo-eu-en.custhelp.com/
India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
http://support.lenovoemc.com/

Similar Messages

  • UPS not recognized by Lenovo IX4-300D

    Hi there,
    My new IX4-300D is not seening Xfinity Pro Series 2000VA 1200W Uninterruptible Power Supply connected by USB.
    QNAP TS-269L on the same subnet has no problem seeing the same Xfinity UPS.
    QNAP TS-269L is presently setup as a master. In GUI added IP addresses for QNAP TS-459 Pro II and Lenovo IX4-300D as slaves.
    QNAP TS-459 Pro II sees the UPS on QNAP TS-269L, but Lenovo IX4-300D is still unaware of the UPS.
    I am using GUI on QNAP and IX4-300D because I am not familiar with Linux and command line.
    I can connect to QNAPs using WinSCP.
    I have two exactly the same UPSs and would prefer to connect IX4-300D to UPS via USB directly.
    If direct connectivity is not possible, I would like IX4-300D to at least recognize that it is a slave.
    What can be done about it? Please provide instructions. Your assistance will be greatly appreciated!
    Thank you!
    Tom

    Hello TuToTom
    I have been unable to find a specific listing of what USB driver the unit uses, however the user manual lists the usb port as the serial connection.  With most UPS devices that list the usb port as a serial power it usually means that the unit uses a usb to serial (rs232) adapter internally.  
    The Lifeline NAS devices support USBHID-UPS enabled UPS devices.  Most APC models, dell, and eaton units can or do use this driver.  This would be different than the usb connected serial link method. 
    I recommend contacting the ups manufacturer to confirm how the usb port on your ups unit functions and proceed from there. 
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Lenovo ix4-300d free space left

    Hello, I have an Lenovo ix4-300d, 8TB. My free space on the servers tells me that there is left 3.8TB, when I look in my Share there is almost no space left. What can I do to get more space in my shares? Now I receive the following message: The amount of free space on your Lenovo ix4-300d is below 10% of your total capacity. And that should not be the case!? What can I do? Thanks for a reaction, PPU
    PPU

    I am sorry but I am not sure what you are referring to by MIB, are you trying yo use Management Information base to monitor free space? Can you please explain more what you are trying to do? 
    You can manage the free space through LenovoEMC storage manager and we UI. You can even set it up to email you when you are running out of free space.

  • Lenovo ix4-300d - Data protection is being reconstructed gets stuck.

    Hi experts,
    After a power loss my Lenovo IX4-300d went on a "Data protection is being reconstructed" phase. This process never ends because it gets stuck at a certain % that changes every time I power on the IX4, at this point it becomes unresponsive and I have to unplug the power cord. I´m using RAID 5, so theoretically there is more than one drive failing. I am not an expert of course, just googled this, I don´t even know if its right.
    In the other hand there is nothing stating a HD failure in the logs or the system status of the IX4.
    So, how can I identify which drivers are failing in order to replace them?
    Could this be a logical failure and be fixed by formatting the drives?
    Any additional comments or recommendation? I am able to access my data while it´s "reconstructing" so I am moving my things out of the nas.
    Thanks
    EG 

    You can try rebooting with one drive removed at a time. If you are having one drive fail you should be able to boot with it missing. You should also check to see if you are still in warranty and call tech support. They will be able to assist in diagnosing the issue and replacing drives if needed.
    Contactos — Latinoamérica

  • Lanovo ix4 300d and european character set for samba shares

    Hi,
    I am installing a couple of IX4-300d at a client site, struggling to set and fix the samba character set for the Windows shares. Here in Italy everyone is used to put western european characters into filenames (for example è ò ° €) but the NAS acts wierdly when it finds such caracters in folder names and file names.
    As you know samba gives the possibility to declare dos charset= ISO8859-1 and unix charset= ISO8859-1 in the smb.conf file but the option is not present in the IX4 setup pages.
    Is there an easy way to circumvent the problem and fix this option? As it is now the machine is fearly useless, at least if you need to migrate files and folder from a server or storage with ISO8859 charset already applied.
    thanks a lot
    np
    Solved!
    Go to Solution.

    This issue has been raised on all iomega drives since day 1. although 'documented' it is still shame, that units sold to 'r-o-w' means rest-of-world, outside US, are stuckto Aa-Zz09 basically wheras client systems ( windows, linux, ios ) don't care and take what they are supposed to do.
    Take it or leave it. ( I mean, take another vendor), I do not believe someone ever has taken that seriously or will do it......
    Various PCs / Laptops ( sorry I still really love Dell and Fujitsu ;-))
    Supporting Customers ix2s and ix4s -- Love Networking ( not only technically ).
    I am not a Lenovo Employee.
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"!

  • IX4-300d and Undelete software

    As in most NAS (if not all) when a file is deleted from a share in IX4-300d it disaappear "completely" from the drive. No chances to recover ii from a Recycle bin.  I read in a post that UNDELETE by Diskeeper  might be a solution creating a "virtual" recycle bin.  I decided to try it and downloaded a trail version of the program.But it did not recognized the drive/shares in the NAS.
    Does anyone has any experience with UNDELETE in NAS?

    Hi hmogena,
    As far as I know, the only way to get back deleted data would be through data recovery. You can either go to a data recovery service or use software to try to recover deleted files. You would need to connect the hard drives to a Linux-based device to be able to read from them.
    Have questions and need answers?
    Search the database for answers to FAQ's, software/driver downloads, tutorials, news, features and more!
    LenovoEMC Support & Downloads
    LenovoEMC North America Support Contact Page

  • Lenovo ix4-300d Russian timezone

    Firmware 4.1.106.31982
    Incorrectly displays the time:
    1) Moscow (gmt+4) - is displayed as gmt+4
    2) Minsk (gmt+3) - displayed as gmt+3
    Request an update package tzdata and bring web-based interface/led-display according to the updated package tzdata.
    Solved!
    Go to Solution.

    Hello nos96
    In regards to the issue you have been experiencing,  Europe LenovoEMC Support will need to be contacted to diagnose the root cause of problem and assist with a resolution.  
    Thank you for posting this issue. 
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • IX4-300d - UPS, not showing in management, but sends messages if I connect and disconnect

    Just acquired a iX4-300d, and updated to the latest firmware (4.1.104.31360).
    On trying to link a UPS (a KSTAR BM-3080) - the UPS Management page just shows "Status: None Connected"
    BUT -  in the EVENT LOGS panes I get the following message:
    Event
    4462          An Uninterruptible Power Supply (UPS) has been recognized.
    and if I unplug the USB connector between the UPS and the iX4-300d - the message
     Event
    4463
    The Uninterruptible Power Supply (UPS) has been removed.
     is shown ----- Surely if it sees a UPS is connected it should show one in the UPS Managment page, of not then why does it show in the Event log console.
    ALSO:
    Given that the iX4-300d seems to recognise a UPS has been connected - is there some way to update/replace or even get to the code related to this UPS mmanagement section,  so I can get readings from the UPS, thus enabling a 'smart shutdown' when the battery drops to say 10% remaining?
    (Could it not be just a "Plug in" that allows smarter people than me to enter the UPS I/O values and make it work with a wider range of UPS devices.
    Additionally - so far I havn't seen a list of "Approved UPS", just a note about some UPS systems that do not work.)
    DG.

    I've tested this with an  ix4-300d and APC smartUPS 1500 ( which is not on the list of compatible UPS ), but it is working exactly as you wish. Somewhere around 15% battery the device will shut down.
    Give it a try....
    B.T.W You may test the notification functionality by unplugging ups main supply. If properly configured this event will shouw up in the log and NAS will sent notification mail ( + another mail when mains are recovered)
    Various PCs / Laptops ( sorry I still really love Dell and Fujitsu ;-))
    Supporting Customers ix2s and ix4s -- Love Networking ( not only technically ).
    I am not a Lenovo Employee.
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"!

  • Ix4-300d iSCSI disconnect Windows 2012R2

    Hello Everyone,
    I just recently purchased (3 days ago) an ix4-300D and updated it to the latest patch.  I have 4 x WD 3TB Disks and they are configured with a raid 0 configuration.  I then have 2 NICs (not bonded) and using the second port for the iSCSI LAN (192.168.100.100, Jumbo Frames 9000) and the 1st port for accessing the device (192.168.1.100).  I carve out 3 TB iSCSI LUN (with CHAP) and give it a name. My Windows Server sees this (under the 192.168.100.X network) and I"m able to bring it online, mount it, format it and use the LUN.  I then start copying about 2.5 TB of Data off an ix2 back to this Ix4 and about 1/4 through the copy, the iSCSI disconnects and the actual unit is frozen., It won't respond to web interface on the 192.168.1.x LAN either. I have to actually unplug it and then plug it back in for the unit to respond.   I know that iSCSI works on the Window Server as I replaced a custom NAS Server using OpenFiler and worked for over 2 years w/o issues/reboots or anything else. The only thing that has changed is the NAS box (the ix4-300d).  Can anyone think of anything I could be doing wrong? What to check? I am thinking it is a bad unit but I want to check everything first.
    I will say the only thing that *could* be out of line (but is VERY doubtful is the problem) is that 3 of the WD drives are 3TB Reds and 1 is a 3 TB Black. I'm going to remove the black drive and redo the entire unit to see if that resolves the problem but I doubt it will.  I know the Reds are "certified".
    I have already removed the Jumbo Frames just in case (though the windows networking card supports Jumbo Frames 9000 since the old SAN was working with these w/o issue).
    Thoughts anyone???

    Hello CPXGreg
    Using a mixed disk array can cause instabilities, so I do recommend that you try using the unit without the WD Black disk for at least testing.
    Next, there are various factors that could cause or contribute to a firmware lock like this.  Usually this is caused by media server crashing, which then escalates to a full firmware lock.  I recommend checking that media server has been turned off for now and any unused protocols.  If the unit still locks up I recommend that you contact LenovoEMC support to have a dump report from the unit reviewed.  This way we can check what may be at the root of the issue.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • I need confirmation, please help me! (about adding new hdd on my ix4-300d)

    Hello,
    I buy recently a Lenovo ix4-300d, I have installed one hdd seagate 2To (ST2000VN000).
    I saved many documents on it..
    Today I want to install 2 others hdd WD 1To (WD10EZEX).
    After reboot a message tells me I need to erase all data on the news disks before I can use it, so I confirm, all seems ok.. After that a message appear on the left "2 disks unused".
    Now (step 3 page74 on the .pdf guide) I need to check the box "add drives to storage system" and click confirm to activate the news disks, so I do, but I have this message:
    "Vous devez supprimer les données existantes pour pouvoir modifier la configuration du disque.
    Cochez cette case pour continuer."
    (in english "You must erase existing data for change the disk configuration" or something like that)
     I don't want to loose all the data on my first hdd already in use.. ..and the 2 others news disks are empty.
    So, there is my question:
    if I check the box and click continue what "existing data" will be erase??
    existing data on all hdd?? Or just on the new one??
    nb: Sorry for "my english" but there is no french section in the forum, and the assistance don't answer me by email, and on the phone there is an answerphone tells me "for help if you don't have the error number code, you must go on the forum, bye.."  .. ..  I hope my question is understandable. 
    Thanks 

    Hello tictictac
    Sorry that you experienced data loss, however it was preventable if a backup had been made as recommended.   
    From the screen shot you sent it looks like the drives were already added to the existing array after the first drive overwrite request.  With the array being made up of mixed disk models and none of the disks showing any green stipes indicating overwrite selection,  I can not say for certain what caused all the disks to be wiped.  I suspect that is was taken as a RAID change and all disks were wiped from there. 
    For future reference please check the device support page to see the guides, FAQ's, and download the full user manual( in French here ) and check with LenovoEMC support in your region.  The Europe support region has several languages available to choose from including the France number +33 17048 0388.  The full list of Europe numbers can be found here.
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • File system error on IX4-300d

    Hi all. I got message "File system error. You must perform file system check". How can I do it? 
    Sorry for my English.

    Hi. Can you tell me how to run fsck command. I have the same problem with the drive and I get the same error :
    "The file system on your Lenovo ix4-300d has errors and needs to be checked".
    I have 2 Hard disks both of 3 TB in simple configuration. The suggestion of file system check did not work. I tried your method of SSH into the hard disk. However I cannot complete the process as I got the following error:
    root@DataVault:/# fsck -y /dev/sdb2
    fsck 1.42.5 (29-Jul-2012)
    e2fsck 1.42.5 (29-Jul-2012)
    /dev/sdb2 is in use.
    e2fsck: Cannot continue, aborting.
    This is consistent with sdb1, sda1 & sda2
    Also I have provided the parted -l info below:
    root@DataVault:/# parted -l
    Model: ATA ST3000DM001-1CH1 (scsi)
    Disk /dev/sda: 3001GB
    Sector size (logical/physical): 512B/512B
    Partition Table: gpt
    Number  Start   End     Size    File system  Name     Flags
     1      33.6MB  21.5GB  21.5GB               primary
     2      21.5GB  3001GB  2979GB               primary
    Model: ATA ST3000DM001-9YN1 (scsi)
    Disk /dev/sdb: 3001GB
    Sector size (logical/physical): 512B/512B
    Partition Table: gpt
    Number  Start   End     Size    File system  Name     Flags
     1      33.6MB  21.5GB  21.5GB               primary
     2      21.5GB  3001GB  2979GB               primary
    Model: SanDisk Cruzer (scsi)
    Disk /dev/sdc: 16.0GB
    Sector size (logical/physical): 512B/512B
    Partition Table: msdos
    Number  Start   End     Size    Type     File system  Flags
     1      16.4kB  16.0GB  16.0GB  primary  fat32        lba
    Model: Linux device-mapper (linear) (dm)
    Disk /dev/mapper/9aee462_vg-lv3a09ce04: 5958GB
    Sector size (logical/physical): 512B/512B
    Partition Table: loop
    Number  Start  End     Size    File system  Flags
     1      0.00B  5958GB  5958GB  ext3
    Model: Linux device-mapper (linear) (dm)
    Disk /dev/mapper/md0_vg-vol1: 17.2GB
    Sector size (logical/physical): 512B/512B
    Partition Table: loop
    Number  Start  End     Size    File system  Flags
     1      0.00B  17.2GB  17.2GB  ext3
    Model: Linux device-mapper (linear) (dm)
    Disk /dev/mapper/md0_vg-BFDlv: 4295MB
    Sector size (logical/physical): 512B/512B
    Partition Table: loop
    Number  Start  End     Size    File system  Flags
     1      0.00B  4295MB  4295MB  ext2
    Error: /dev/mtdblock0: unrecognised disk label
    Error: /dev/mtdblock1: unrecognised disk label
    Error: /dev/mtdblock2: unrecognised disk label
    Error: /dev/mtdblock3: unrecognised disk label
    Error: /dev/mtdblock4: unrecognised disk label
    Error: /dev/mtdblock5: unrecognised disk label
    Error: /dev/mtdblock6: unrecognised disk label
    Error: /dev/md0: unrecognised disk label
    Error: /dev/md1: unrecognised disk label
    root@DataVault:/#
    Any help would be greatly appreciated.
    Thanks in advance

  • Ix4-300D as iSCSI target cause alert disk is full

    I am using ix4-300D with RAID5 as iSCSI target.
    Once I create largest volume using all capacity, ix4-300D sends warning disk is full.  Because we monitor this iSCSI target using E-mail alert, I want to eliminate this warning message.  There is no configuration point on Web management GUI.  
    I guess other people using this unit as iSCSI target have same concern.  If you know something, please help me about this.  Thanks in advance.
    Alert message:
    The amount of free space on your Lenovo ix4-300d is below 10% of your total capacity.

    Thank you for your reply.
    I gave up to use 11% of diskspace as iSCSI target of VMware ESXi because catching alert message is more important for production environment.  I hoped interface to disable some type of alerts.
    I am not sure about using remained 11% space for NFS NAS or something.  It is because iSCSI Target volume will contain VM Guest OS volumes which require very stable operation. 

  • Probleme d'identification ix4 300d

    bonjour Je viens d'acquerir un nas lenovo ix4 300d  mais lors de l'installation le systeme m'indique qu'il est indisponible or j'ai bien installe le logiciel , l'icone apparait sur mon pc . La connection a ete verifiee,comment resoudre ce probleme  merci

    I just acquire a nas lenovo ix4 300d but when installing the system tells me it is unavailable or I have installed the software, the icon appears on my pc. The connection was verified,
    how to solve this problem   thanks

  • How do I disable administrator username and password entry to access ix4-300d

    With the recent version 4.1.102.29716 update, I am now FORCED to enter a username and password to get into my "home based" ix4-300d NAS.  This has already been a MAJOR pain for my nedia server setup, in that I am no longer able to create a network drive to one of several NAS folders on to my home network.
    My question therefore is, how do I DISABLE the function of having to enter an administrator username and password to gain entry into my ix4-300d?
    Thanks,
    Bill

    No hazzle, just do it.
    This is only for admin purposes. You are still able to place your media into individual user shares or put it in the public area where they will be accessible for everyone, even if you set 'security' on.
    Various PCs / Laptops ( sorry I still really love Dell and Fujitsu ;-))
    Supporting Customers ix2s and ix4s -- Love Networking ( not only technically ).
    I am not a Lenovo Employee.
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"!

  • IX4-300D Lenovo NAS - faceplate

    Just recieved a brand new IX4-300D Lenovo NAS LCU-101759656  but faceplate clips damaged in shipping.  Is it possible to get a replacement faceplate?

    Hi Debonator,
    Where did you purchase your new device from? We typically do not replace specific parts like the front faceplate and would replace the entire device under the warranty if the device is damaged, but the replacement device will be a refurbished unit. I would recommend contacting the reseller that you purchased the device from first to see if they can replace the unit for you brand new.
    Have questions and need answers?
    Search the database for answers to FAQ's, software/driver downloads, tutorials, news, features and more!
    LenovoEMC Support & Downloads
    LenovoEMC North America Support Contact Page

Maybe you are looking for

  • SAP query variant issue

    we have done a query in sq01.i have downloaded it from production to development. now i am trying to execute the query , but it is sowing a dialog box to select the variant. i am selecting variant as standard.after executing the query it is giivng me

  • IME 6.2.1 cannot load configuration

    Hi I have two IDSM upgraded til 6.2.1E3 and need IME 6.2.1 to manage those. Status and event monitoring works just fine but when I try to access the configuration I get the error message "An error occured loading the configuration" The console window

  • I upgraded to os yosemite and now illustrator does not open

    i get a screen that reads install java legacy which i installed already and the problem still occurs

  • Can vendor be controlled as per PO document type ?

    Can vendor be controlled as per PO document type ? I mean vendor for stock type should not be allowed for non-stock type.

  • GetURL Error... Can't redefine value