Letter of volatility for PXIe-1071

I'm looking for a Letter (certificate) of Volatility for the following, please:
PXIe-1071
PXIe-8135
PXIe-8234

Hey,
This is the type of request that would be better suited for an official service request via our support system. Since there was a nearly identical request submitted recently, I am going to assume that it pertains to the same incident and handle it via that channel.
Matt W.
Applications Engineer
National Instruments

Similar Messages

  • Letter of volatility for PXI-2568

    Hi,
    I woud like to find a letter of volatility for PXI-2568; it is a relay module with, what it appears to me, some logic circuitry on the output. I have searched both the forums and NI's main website without any luck. Can someone here provide the documentation needed? I would very much appreciate it.

    Hello RFdigit,
    You have not been able to locate it online because National Instruments reserves control over this document. With your permission, post an update on the forum so I can send you an email containing this information. 
    Best regards,
    Ali M
    Applications Engineer
    National Instruments

  • Letter of Volatility for PXI-8108?

    Is there a Letter of Volatility Available for the PXI-8108 describing volatile and non-volatile memory

    To anyone interested in getting a Letter of Volatility (LOV):
    We have started posting LOVs on some product pages of our website in the resources section, so it is worth checking there before contacting us. In many cases, as it was in this one, we have not made the LOV publicly accessible at this time.
    In that case, the most efficient way to get LOVs is to contact our support engineers by calling 866-ASK-MYNI (275-6964). They will be able to talk to you about your need for the document and speak with our internal resources to get that to you fairly quickly.
    Regards,
    Ben R.
    Modular Instruments Product Marketing Engineer
    National Instruments

  • Letter of volatility for PXI

    Hello,
    I am in need of Letters of Volatility for the following PXI components.
               - PXI-8431/8
               - PXI-2503
               - PXI-4065
    Thanks in advance

    Hello RFdigit,
    You have not been able to locate it online because National Instruments reserves control over this document. With your permission, post an update on the forum so I can send you an email containing this information. 
    Best regards,
    Ali M
    Applications Engineer
    National Instruments

  • I need a letter of volatility for the PXI-1042 chasis.

    I need the standard security information needed to confirm that sensitive data passing through National Instruments PXI-1042 chassis has been replaced been fully cleared.

    Hello ECohen and anyone who might need this in the future,
    Here is the letter of volitility for you.  Cheers!
    ColeR
    Field Engineer
    Attachments:
    PXI-1042(Q) Letter of Volatility.pdf ‏13 KB

  • Bluetooth connectivi​ty for PXIe-1071, PXIe-8133

    Hi, There are about 24 numbers of NI PXIe-1071 chassis with PXIe-8133 controllers in our lab. I would like to interface a Bluetooth device (EEG and ECG monitors) with the DAQ. The DAQs are running Windows 7 and LabVIEW.
    How would you suggest I connect the Bluetooth devices to the DAQs?
    If I buy Bluetooth dongles that fit via the USB is that a good solution?
    Thanks.
    Philip

    Hi PKP,
    Since your controllers are running Windows 7, they function just as a normal computer would; therefore the USB ports would behave just as a desktop would. You could load the drivers onto the controller and collect data from the bluetooth device that way. Do you have software to read the EEG and ECG signals into LabVIEW?
    Best,
    tannerite
    Tannerite
    National Instruments

  • Letter of Volatility

    Please provide me with a Letter of Volatility for the Motion Control Boards PCI-7344 and PCI-7354. I would also appreciate one for the Video Capture Board PCI-1409. A declassification procedure for each of these boards would also meet my requirements. Thanks.

    I don't believe there is a price for the letter, but I could be wrong. The best way to proceed with this, if you call us at 1-866-ASK-MYNI (1-866-275-6964) and create a service request, or I can pull your information and send you this information myself if you give me permission to access your information for that purpose.
    National Instruments
    Applications Engineer

  • VXI-1000 Letter of Volatility

    I'm trying to locate a Letter of Volatility for the VXI-1000 Mainframe, but haven't had any luck searching the web site.  I tried to submit a support request but don't have a membership number to do so.  Any help would be greatly appreciated.  Thanks. 

    Hello mdbeer,
    The VXI-1000 main frame was End of Life (EOL) in approximately 1997 and thus the documentation such as the Letter of Volatility is unavailable. I apologize for the inconvenience.
    Regards,
    -Travis E
    National Instruments
    Applications Engineer

  • Letter of Volatility - VXI-PCI8026

    Hello,
    I work in a secured area and we recently purchased 2ea of the VXI-PCI8026.  Can someone direct me to a Letter of Volatility for the EEPROM on the VXI-MXI-2 and PCI-MXI-2 module/board?  Also, what exactly is the size of the EEPROM, I couldn't find this mentioned anywhere in the manual.
    Thanks,
    - Darin
    Solved!
    Go to Solution.

    Darin,
    Thank you for using the Forums.  I believe the document that you are looking for can be found here.  
    I hope that helps.
    Brian P.
    Applications Engineer
    National Instruments

  • Getting DataSocket for LV RT 5.0.0 installed on PXIe-1071?

    Hello all,
    Hopefully this is just an easy to answer question, but since I got so stuck on this I'll ask it anyway.
    How do I install "DataSocket for LabVIEW Real-Time 5.0.0" (on a NI PXIe-1071 module with MAX)?
    Installing software with MAX and getting it on they module is not the problem, the problem is that I can't find any setup file to download that has the specific program: "DataSocket for LabVIEW Real-Time 5.0.0".
    The system we use is a:
    - NI PXIe-1071
    With the modules:
    - NI PXIe-8100 (Embedded controller, Slot 1)
    - NI PXI-7951R (FPGA with NI 5751 adapter module for flexrio, Slot 2)
    - NI PXI-5402 (Function generator, Slot 3)
    The software we have installed can be seen in the picture (Attachment) (And yes we also need to resolve the driver problem for the function generator in slot 3 as can be seen in the picture
    All software in installed with MAX, all NI drivers have been updated in the last two days to the latest versions. A lan connection (with same subnet) connects our host computer with our NI PXIe-1071 box.
    The reason we need the "DataSocket for LabVIEW Real-Time 5.0.0" is that we are creating a copy of a working existing system.
    When trying to find it on the NI support pages we keep finding a page that directs to the page to instal NI LabVIEW Run-Time Engine 2012. After downloading and trying to install it we get this message: "Cannot install - NI LabVIEW Run-Time Engine 2012 f3 (higher version already installed)"
    Thanks in advance,
    Sander Breur
    Attachments:
    130301_Software_list_installed.png ‏21 KB

    Finished: Found an answer.

  • Where i can find exemples for PXI-2564 relay module

    hello,
    I'm beginner in PXI module using.
    I bought a PXI solution for use it as a custom instrument.
    My aim is to read RTDs and command some line using relays.
    So i take the system below:
    NI PXIe 1071
        PXI-8100
        PXIe-4357
        PXI-2564
    I can see all the material on NI MAX.
    In MAX, i can read RTD a channel value and can operate relays.
    i have read and practice exercice on "Getting started with Labview RT module" and all it works,But i don't find any resources or exemple to deal with relay card or read RTD.
    I have try to access it using "visa connect" and this step works, but what must i do to go further.
    In a first time i want to swap relay position, by reading position, invert value ,set position and return the value.
    And for RDT i'll want to make a simple measure and make a average a N measure for 1 or all input.
    Can you give me some exemple or trick?
    Best regards

    Hello,
    What software do you use? what version?
    Have you look into the LabVIEW Example Research with KeyWord "Relay". There are examples with NI-DAQmx and niSwitch drivers.
    Thanks
    Brice S.
    National Instruments France

  • Where to find connectors for PXIe plugin card

    Can anyone help with information about XP4/XJ4 connectors for PXIe: Suitable vendor type numbers?
    We want to make a custom card to plug into a PXIe-1071 chassis - but only need the 3.3V power from the chassis. But after long search I was unable to find a type number for such a connector. XJ4 is the smallest but obviously any of the connector types will do as they all have power pins.
    Solved!
    Go to Solution.

    Hello heel.
    I have searched in our internal papers, and according to my findings we are using ERNI as a manyfactor for our connectors.
    ERNI
    Also, since you want to design for own PXI board, you might be able to find some usefull information in the PXI specifications.
    PXI Systems Alliance
    I hope you can use this information.
    Best Regards
    Alex E. Petersen
    Certified LabVIEW Developer (CLD)
    Application Engineer
    Image House PantoInspect

  • PXIe 1071 remote power up

    The PXIe 1071 chassis is located inside a panel which is normally kept closed. Every day morning at start of shift, the operator has to open the panel door and switch ON the White button in front of the controller. This is something they are not happy doing as the panel does have high voltage switchgear at the bottom level.
    Earlier with PCI boards and normal Induatrial computer we could wire the Power ON / OFF button to a switch outside the panel. Whihc was in parallel with the built in power switch of the PC.
    I would like to get the same functioanlity with the PXI also, as noted below :
    - When the panel is powered up, the PXI also powers up and loads the WIN7 OS.
    - The operator launches the application and completes testing.
    - When done he quits the application, shuts down the PC.
    - Powers down the panel and goes home.
    I have already treid to read the manual which talks of a SW1 switch but the description is quite ambigous as to what it does :
    When switch 1 of SW1 is on, the backplane controls the power supply on/off state. This allows you to circumvent the controller and turn the chassis on/off manually. When switch 1 of SW1 is on, the power supply turns on when you press the front panel power switch....
    I really am not clear as to what hey are trying to say. And since the system is now with client, I need to be sure before I propose to change default settings. Trial and error will look not so good.
    Raghunathan
    LV2012 to Automate Hydraulic Test rigs.

    Hi Ming,
    I apologize for my confusion regarding the functionality of the DB9 inhibit switch versus the white power button.  I must have misinterpreted the descriptions in the User Manual.  It seems that the white power button can hibernate the system whereas the DB9 inhibit switch just cuts off the power.  In order to properly shut it down without using the white power button you will need to first hibernate or shutdown the computer through the Windows interface, then you can use the DB9 inhibit switch to remotely cutoff the power to the chassis and later turn it back on.  I am not aware of another simple 'one press button' type way to remotely hibernate the PXI controller.
    Since your chassis is located in a cabinet you could run keyboard and monitor cables to the device to interface with it.  Alternately, you could connect the chassis to the internet and use Remote Desktop to shut it down.
    Regards,
    Barron
    Applications Engineering
    National Instruments

  • PXIe-1071 maximum ram?

    We have a PXIe-1071 and would like to upgrade the memory from the existing 4 GB.  What is the maximum this board will support?  I opened it up and found 2 SODIMM slots occupied by 2 GB.   Will it take 4 GB sticks (for a total of 8 GB) or 8 GB sticks (total of 16 GB) ? The manual  and NI page mentions nothing about RAM at all, but the page for the PXIe-8135 says it supports 16 GB.   

    If the spec say 8GB is your limit, then 8GB is your limit.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Driver Setup for PXI 2569 and PXI 2529 in Switch executive

    Hi,
    What sould be tha "Driver Setup" for PXI 2569 and PXI 2529 in Switch executive under 'Driver Session"
    Regards!!!
    Vineet Shukla

    Hi Vineet,
    You do not need to insert anything under Driver Setup.  Anytime you are using NI switches, you can simply click Configure NI Switches when creating a NI Switch Executive Virtual Device to configure the topology settings of those switches.
    Just so you know, you can insert information under Driver Setup, and then you wouldn't have to use the Configure NI Switches wizard.  More detail on what to insert under Driver Setup can be found in the following KnowledgeBase:
    How Do I Create a Virtual Switch and Use it in my Application?
    http://digital.ni.com/public.nsf/websearch/A1F0D6A3357E14B386256E4B0071FDA2?OpenDocument 
    In short, you would type "Topology:" followed by the topology name such as "2569/100-SPST" or "2529/2-Wire 4x32 Matrix".
    Let me know if you have further questions or if this does not resolve your issue!
    Chad Erickson
    Switch Product Support Engineer
    NI - USA

Maybe you are looking for

  • I used the search function, and gaming is VERY unclear

    Half of the people say do not buy a macbook for gaming, the other half say you can play games on it. I looked around, and apparently you can play WoW, every steam game, etc. My question: Will Counter-strike 1.6 run well? I really want to know, since

  • TOC able to recognize a chart or table or images (jpeg format)?

    Hi, I've added a couple of charts to my Pages 09 document, and was hoping the table of contents would show the chart as something like "Chart 1" or even use the title of the chart. Is there anyway to make this happen? I have, of course, gone back and

  • How to copy video in my iphone 4s

    how to paste video in my i phone 4s

  • Microsoft Click to Run won't open Microsoft Word Starter 2010

    The error message says it cannot open Microsoft Word Starter 2010 to try again or to repair in Control Panel.  I have no idea how to repair it.  Any suggestions? I am running Windows 7 Home with an HP 2000 notebook pc.  64 bit Operating System. Thank

  • Type-pools in class

    Hey guys, did someone of you recognized the strange behaviour of the ABAP workbench if you insert TYPE-POOLS in public section of the calss. If you than add a method to the class as PUBLIC, the TYPE-POOLS definition get lost. How could i use TYPE-POO