Linking Priority and ABC indicator

Gentlemen,
Here i have an interesting requirement. My customer require to set the priority of notification based on the equipment criticality, ie based on the ABC indicator.
How to link these two things ( Priority in notification and ABC indicators of Tech object ) object and make it default.
Please throw your valuable ideas.
Regards
Srinivasan Madaswamy

Dear Pete,
Yes, this default data can be allowed to get  into notification while saving.
The only criteria is to have automatic population of priority field based on criticality of equipment.
Regards
Srinivasan Madaswamy

Similar Messages

  • Link between ABC Indicator and Priority

    Hi friends,
    My client requires the Link between ABC Indicator and Priority. i.e., While creation of notification, based on the ABC indicator assigned in the Equipment, Priority should be selected.
    Is it possible, if possible please help me out to resolve this issue.
    With Best Regards,
    Dev

    Hello,
    Yes you can acheive this by Development use the Below User Exit or Fubctional Module to get it done
    User Exit-->QQMA0014 QM/PM/SM: Checks before saving a notification
    BADI-->NOTIF_EVENT_SAVE Change When Saving Notification
    When Notification create against the Equipment which Having ABC Indicator it will stop Notification while Saving the Notification By checking The ABC Indicator on Equipment and Proposes Priority which You already defined in Configuration with Proposed New Dates for Notification Completion Dates.Notification save allowed once you fill Exact value of Priority.
    Regards,
    Rakesh

  • Vendor report for ABC indicator field

    Hi All,
    My client uses field ABC indicator in the purchasing data view of the vendor master. They want to have reports based on this field.
    Are there any standard reports in SAP which can give total purchased value and quantity for a vendor with specific value of ABC indicator?
    Regards,
    Vishal

    Hi Vishal
    you can try with T code ME81N
    link:[http://help.sap.com/saphelp_45b/helpdata/en/75/ee128c55c811d189900000e8322d00/frameset.htm]
    Hope this helps
    Regards
    Vikrant

  • ABC indicator for project stock

    Is there a way to run MIBC and assign abc indicator to project stock that is not valuated or even for the part numbers to show up on this list?  What needs to be done in order for this to show up on the report?  IS there a way to make it valuated and but not company own stock valuation?

    Hello Kimberly,
    MIBC report will show the list of material based on the Consumption or Requirement and it will suggest ABC indicator considering the both factor.
    The Project stock can be managed as valuated project stock or nonvaluated project stock.
    For more details, please have a look on the following link
    <a href="http://help.sap.com/saphelp_46c/helpdata/en/4d/2b92c943ad11d189410000e829fbbd/frameset.htm">Project Stock</a>
    Hope this helps.
    Regards
    Arif Mansuri

  • Configuring QoS for FIOS Router MI-424WR: Traffic Priority and Shaping

    Please only read on if you are an experienced internet user familiar with setting the advanced QoS and Firewall settings for the MI-424WR and make use of wireless adaptors from a PC to provide connectivity.
    This is my first post and my first week since I moved from Time Warner Cable over to FIOS for iNet (plus HDTV and phone).     While all my services work, the router as delivered and setup is not optimum for internet quality of service.  Instead it was probably out of the box optimized for HDTV and telephone to satisfy most customers and reduce support overhead.   The average FIOS consumer is multimedia sensitive, but that is not so in my genre of internet consumer.   Here in lies the core of my reason for seeking help from like minded and experienced users in this community.
    One of the main driving forces in my switching to FIOS was to improve my multiplayer gaming experience where ultra low ping latency and high upload data rates dramatically affect the quality of connection and thus gameplay.    The cable internet service from TimeWarner was providing solid 2MB/1MB down/up data rates with no issues like what Im having now with FIOS.   Again the reason for the switch was both financial and in hope of gaining better data rates and quality of service.   Now with FIOS Im getting about 24/15 down/up data rate on the Extreme FIOS 25/25 plan when measured from my house to Los Angeles server (50 miles away) via Speedtest.net or DslReports.com/tests.     Latency wise, the ping has gone down from 150 to 50ms when measured to my friends who I connect to online that are on the East coast.   The data rate and latency has greatly improved in going from Cable to FIOS.   So far, so good.
    Where the problem shows up now, is that now I get an internet "hiccup" every 5-10 minutes that lasts about 1/2 to 2 seconds.   For the average internet user that just streams multimedia or cruises on the net; this is probably undetectable or noticed.   I never had this problem over the same PCs connected wirelessly to my DLINK DGL-4500 Gaming Router when my ISP was TimeWarner's cable service.    Now, using the FIOS and MI-424WR router with everythings being the same; Im experiencing this degregation in quality of service.    Even putting the PC's IP into the DMZ doesnt make any difference, so it is not related to port forwarding.    The issue is squarely in the lap of FIOS and this router as delivered and configured.    This is where the "game" is a foot, and where I need expertise in an area Im new to. 
    I am not new to being hands on with inet trouble shooting asI have been setting up my own home network (I work from home over VPN to work) for decades;  I would like to leverage the skills of those who are experts in the area that I think can address this issue.   That being QoS and the other device class mechanisms of this router.   Its my guess that this periodic hiccup can be minimized and even eliminated using these advanced features of this all-in-one TV/iNet/Tele router.   
    With that context being laid down, this hiccup doesnt show up if:
    a.  I connect two PCs connected to the same ethernet hub of the MI-424WR (traffic just over the LAN and not WAN)
    b.  When I was on Cable with my own gaming router wirelessly DHCP connected to my PC and using port forwarding or using the DMZ.  
    The hiccup does exist when:
    a.  Going from internet through the MI-424WR to the wireless DHCP connected PC with port forwarding
    b.  Even putting the wireless DHCP connected PC into the MI-424WR's DMZ has no effect
    I did read the manual and tried some QoS pritority and shaping and managed to reduce how often the hiccup occured, but I was just making guesses at the settings.   I put in the IP for the PCs I use for my gaming applications (which are very ping and jitter sensitive) into the QoS priority (value 7) and shaping GUI.    Im hoping someone with experience can tell me exactly how to use it and what settings to input.   Im not clear on the device and connection types offered in the QoS menus. 
    Another thing, is I couldnt find settings for the turning on/off the ICMP echo.   But I assume this is on because it can be pinged by folks on the net to my WAN IP.
    Here is the manual for the Verizon provided M424WR router (Current Version of firmware: 20.10.7)
    download link
    Here are the QoS traffic priority and shaping values Ive been experimenting with:
    Click to view QoS Traffic Priority
    Click to view QoS Traffic Shaping
    And why it matters to have a solid and stable inet connection for internet gaming?  The hiccup causes slewing or jitter which equates to positional errors in the 3D world that ruins the smooth gameplay that is needed for high end gaming.
    Heres a snapshot of me flying the wing of another flight simmer who is on the East coast and me on the West coast.
    Click to view
    Thank you in advance.
    Thomas "AV8R"
    MSEE

    TMAS wrote:
    the router as delivered and setup is not optimum for internet quality of service.  Instead it was probably out of the box optimized for HDTV and telephone to satisfy most customers and reduce support overhead.  
    That's not accurate.  VZ telephone service does not go through the Actiontec.  Also, there are no default settings for QOS in the Actiontec since QOS is rarely needed with FIOS upload speeds.
    TMAS wrote:I get an internet "hiccup" every 5-10 minutes that lasts about 1/2 to 2 seconds.  
       You should not be experiencing periodic "hiccups".  Something is clearly amiss.
    TMAS wrote:
    With that context being laid down, this hiccup doesnt show up if:a.  I connect two PCs connected to the same ethernet hub of the MI-424WR (traffic just over the LAN and not WAN)
    The hiccup does exist when:
    a.  Going from internet through the MI-424WR to the wireless DHCP connected PC with port forwarding
    b.  Even putting the wireless DHCP connected PC into the MI-424WR's DMZ has no effect
    Lets see.  The issue shows up on a wireless connection, but not a wired connection.  You think this is a QOS issue and not a wireless issue why?  Have you tried changing the wireless channel?  It very possible you have neighbors on the same channel.  Is the DGL-4500 wireless still on?  Could that be interfering?TMAS wrote:
    Another thing, is I couldnt find settings for the turning on/off the ICMP echo.  
    The settting to enable/disable ICMP echo is on the Firewall/Remote Administration page.
    TMAS wrote:
    Here are the QoS traffic priority and shaping values Ive been experimenting with:Click to view QoS Traffic Priority
    Click to view QoS Traffic Shaping 
    The traffic proirity settings you linked are applied only to your wireless connections.  QOS between the router and your wireless PC will only serve to prioritize traffic between the router and that PC and have no affect on your internet traffic.  Assuming you are not running browsers, VOIP and other traffic from that PC while you're gaming, then that will not accomplish anything.  i.e.  You're giving your only traffic highest priority, but that traffic is not competing with anything (except other nearby wireless connections on the same channel).
    On the traffic shaping screenshot, you have broadband ethernet checked, but according to your other thread, your WAN connection is Broadband Coax, not Broadband ethernet.

  • Updation of ABC indicator in Material Master

    Hi,
    For ABC analysis, I carried out it according to T_code MC40(Usage value). I got the category of material. For eg "A".But how the ABC indicator updates in Material master.Because I couldnt get indicator in MRP1 view.
    Whats the right way? Pls guide me.
    Thanks,
    Goraksh.

    Hi,
    Update of consumption is based on movement type, and you can decide which movement types should have or have not consumption updating.
    Check in transaction OMJJ if the movement types in question have indicator "Consumption posting" (field V_156_VC-KZVBU) as marked.
    If it is the case, consumption is updated, opposite for un-ticked.
    Hope that helps.
    Thanks.

  • ABC indicator removal

    Hi
    Having some clarification cycle count indicator...
    1) How to mass remove the ABC indicator set for the material master ?
    ie,  mass change from a indicator specified to blank field.
    I believe this is kind of basic qsnts, really appreciated your support.
    Thanks
    MM

    Hi,
    Just tested this out in my system and it works. Here's what I did.
    1) Execute MM17
    2) Choose Fields Tab --> Search for MARC-ABCIN and then highlight and execute
    3) Enter Material and Plant then execute
    4) At the new values line, leave it blank then, click on carry out mass change button
    5) Save
    Even with CC Fixed indicator checked, I am still able to change the value to blank.
    Hope this helps
    Regards,
    Nazrin

  • ABC Indicator sap PM

    Hi PM gurus
    I have a problem. I change a ABC Indicator value of Functional Locations to A via transaction IL02. However, when i get a report with transaction IW38, I dont see A value in ABC Indicator field in some of the Functional Locations. I am sure I have changed and saved the value of that field. What may be the reason? Do you have any idea? Thanks in advance

    check the change history, maybe someone else has changed it again.

  • ABC indicator in Material Master

    Hi experts,
    Could you please let me know if the ABC indicator field used in MRP1 view is Plant dependant or Plant independant?
    We have 2 plants. So should we set this ABC indicator seperately for Plant 1 & Plant 2?
    Thanks,
    Pri

    ABC INDICATOR:
    Indicator that classifies a material as an A, B, or C part according to
    its consumption value. This classification process is known as the ABC
    analysis.
    The three indicators have the following meanings:
    o   A - important part, high consumption value
    o   B - less important part, medium consumption value
    o   C - relatively unimportant part, low consumption value
    So we can say that this information in Material master is plant specific (Plant dependent)
    Logically if we think the material which is of high importance and have high consumption in one plant need not have to be important with same level of consumption in another plant.
    Rerward if it is helpful
    Regards
    Pavan
    So when doing the bifercation of the materials based on their importance it is plant which is of utmost importance

  • ABC Indicator for Equipment & Functional Location Same or Different

    Hi All,
    We can find ABC indicators in both Equipment & Functional Location (FL) master data.
    Q. Please tell me....whether these fields are different for Equipment & FL or same??
    Problem is that I could see the same field name ABCKZ for both Equipment & FL in tables V_EQUI & ILOA respectively.
    Sundar

    Hi  Sunder
    *The ABC indicator can be entered in equipment as well as functional locations.*
       An indicator that is assigned by the procedure of ABC analysis.
    The following ABC indicators are possible:
    A - Important
    B - Less important
    C - Relatively unimportant
    According to these criteria, "A" materials are those materials that are of greatest importance for the production operations of a company.
    Examples of use for ABC indicators are vendor master records, material master records, and master records of *technical objects.*
    So ABC indicator is same for equipments and Functional LocationBUT value may be diferent
    Regards
    Jitender Suhag

  • Mandatory check for ABC Indicator- MRP1 view

    Dear All,
    I want to make ABC Indicator mandatory for ROH material type and to the particular plant. How can I achieve this?
    I tried to change in customization (Change 'Field selection for data screens' ), but its effecting other fields also. because in the field selection group 51 has so many other fields.
    Should I have to create new field section group & field reference Or any other way? Need your valuable guidance.
    Thanks.

    hi Vijay,
    if you want to control it thru configuration then you have to create a new field selection group and then you can make the ABC indicator mandatory.
    you can also use the user exit in material master which will throw an error message at the time of saving of material master if the ABC indicator field is blank.
    Regards,
    Anoop singh

  • ABC Indicator field in PM MODULE

    Hi gurus,
    I have a problem. I change a ABC Indicator value of Functional Locations to A via transaction IL02. However, when i get a report with transaction IW38, I dont see A value in ABC Indicator field in some of the Functional Locations. I am sure I have changed and saved the value of that field. What may be the reason? Do you have any idea? Thanks in advance....

    Hi,
    The value shown on IW38 will be the ABC Indicator as recorded on the order. When the order was created this value would have defaulted from the functional location. If you later change the functional location value, that is not updated on existing orders.
    You can change the ABC Indicator value directly on the orders location tab (provided it is not completed).
    -Paul
    Please use [Enterprise Asset Management (EAM)|Enterprise Asset Management (SAP EAM); forum for PM/CS specific topics

  • BDC- To add ABC indicator in MM02-- MRP1

    Hi,
    I am working on BDC- To add ABC indicator in MM02--> MRP1.
    Problem -->
    In some material+ plant  - Reorder point is there. In this case I need to take additional 'BDC_okcode' for ENTER.
    HOW CAN I DO THIS? 
    I tried it with 'Select statement' between the Perform statement, but it's not working?
    IF wa_file-matnr IS NOT INITIAL.
          PERFORM bdc_dynpro      USING 'SAPLMGMM' '0060'.
          PERFORM bdc_field       USING 'BDC_CURSOR'
                                        'RMMG1-MATNR'.
          PERFORM bdc_field       USING 'BDC_OKCODE'
                                        '=ENTR'.
          PERFORM bdc_field       USING 'RMMG1-MATNR'
                                        wa_file-matnr.
          PERFORM bdc_dynpro      USING 'SAPLMGMM' '0070'.
          PERFORM bdc_field       USING 'BDC_CURSOR'
                                        'MSICHTAUSW-DYTXT(11)'.
          PERFORM bdc_field       USING 'MSICHTAUSW-KZSEL(11)'
                                         'X'.
          PERFORM bdc_field       USING 'BDC_OKCODE'
                                        '=ENTR'.
          PERFORM bdc_dynpro      USING 'SAPLMGMM' '0080'.
          PERFORM bdc_field       USING 'BDC_CURSOR'
                                        'RMMG1-WERKS'.
          PERFORM bdc_field       USING 'RMMG1-WERKS'
                                        wa_file-werks.
          PERFORM bdc_dynpro      USING 'SAPLMGMM' '4000'.
          PERFORM bdc_field       USING 'BDC_OKCODE'
                                        '=BU'.
          PERFORM bdc_field       USING 'MARC-MAABC'
                                        wa_file-maabc.
          SELECT SINGLE minbe INTO v_minbe FROM marc
                       WHERE matnr = wa_file-matnr
                         AND werks = wa_file-werks.
          IF v_minbe GT 0.
            PERFORM bdc_field     USING 'BDC_OKCODE'
                                        '/00'.
          ENDIF.
        ENDIF.
        CALL TRANSACTION 'MM02' USING it_bdcdata MODE p_mode MESSAGES INTO it_msg.

    Hi,
    Try to use Bapi and see ..Please find the sample code.
    LOOP AT t_itab INTO wa_itab.
        CALL FUNCTION 'CONVERSION_EXIT_MATN1_INPUT'
          EXPORTING
            input        = wa_itab-matnr
          IMPORTING
            output       = wa_headdata-material
          EXCEPTIONS
            length_error = 1
            OTHERS       = 2.
        IF sy-subrc <> 0.
          MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                  WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
        ENDIF.
    prepare the follwing structres ( plantdata,headdata, plantdatax)       .
    * Select the MRP view
        wa_headdata-mrp_view =  'X'.
    * Call the Bapi to create the MRP view.
        CALL FUNCTION 'BAPI_MATERIAL_SAVEDATA'
          EXPORTING
            headdata       = wa_headdata
            plantdata      = wa_plantdata
            plantdatax     = wa_plantdatax
          TABLES
            returnmessages = t_return.
    ENDLOOP
    Regards,
    Nagaraj

  • Equipment ABC indicator mapping

    Hi  PM Gurus
    Need some help I need to fill up three fields in technical object master data which is existing.
    1.     Technical object type u2013 ( like rotating , fabricated , instruments etc..)
    2.     Catalog profile u2013 ( sub classification based on identified object type like pump in a rotating object type)
    3.     ABC indicator u2013 ( should be identified based on established parameters like frequency of failure and repair cost)
    For 1&2. Technical object type - i had used the EQUI - long text field and if any match found like pump then it was identified as rotating equipment and pump catalog profile fileds are filled up . (Any best practices for mapping similar to this approach)
    Any best practices / Mapping of fields to obtain the frequency of failure (like <1 year, 1-3 year , 3-10 year) & Repair cost of technical object ( based on this ranking of ABC indicator is to be carried out)
    Thanks

    HI
    A, B, C indicators are used to classify  technical objects according certain criteria such as importance from production point of view say A- denoting those objects failure of which causes production loss & critical to the process & multiple implications in process
    B - causes partial production loss
    C-causes no production loss (have standby)
    This indicator has to be assigned to technical object prior to transactions & you will get the failure analysis once you do transactions over a period of time. After wards you will come to know about the failure frequency & it will not follow any pattern. Hence failure to be analysed based on object class/object type/damage/cause/object part & also location & manufacturer etc.
    Shakti

  • Difference "abc indicator" in MRP1 & "cc phys inv ind" in plant data stor1

    Hello,
    we want to do cycle counts and I noticed that there are two different field in the material master for that.
    I think they have a different purpose?
    "ABC indicator"  field in MRP1 view
    and
    "cc phys inv ind" field in plant data/ stor 1 view
    Can somebody please explain the difference?
    Thanks
    Anne

    MC40 and MC41 dont need customizing, setting can be made in selection screen.
    ABC analysis for cycle count MIBC needs customizing.
    In MRP1 view the field name is MARC-MAABC while on storage location view the field name is MARC-ABCIN.
    The one on storage location view is used for cycle count, and includes ABC and D, and is caclulated by MIBC transaction.
    The indicator in MRP1 view is calculated and updated by MC40 and MC41 transaction
    MICN is the only one that can update the indicator used for cycle counting.
    if you execute both transaction with same settings, then there should be the same result.
    However, pretty often the cycle count indicators are precalculated by MICN based on consumption, but then individual items are changed to get a different indicator for specific reasons.
    You may have a low value item, which is very important for your processes.
    Based on consumption values it may get indicator C, but if you have differences on that item then it is a critical factor for your business, hence you want count it more often, thus you would manually change it to B or even A. (which can be done directly from the MICN report)
    The focus on both indicators can be equal in many companies, but may also be different in other companies, hence you need 2 indicators for ABC analysis

Maybe you are looking for

  • Stickies not opening!

    Hi everyone, I cannot get my stickies program to open! It will try to open (I can see it bounce around on my dock) and then it disappears after a few moments. I've already tried deleting the com.apple.stickies.plist file to see if that would help (as

  • Withholding tax warning message

    Hi we maintain the witholding tax at invoice & payment level both in vendor master data, due to this system always deduct TDS twice at the time of posting. we want a check at the time of invociing and payment, system should ask about TDS whether this

  • URGENT - Query to get employes with multiple cost center

    Hello, The sample data for my requirement is: create table a (year     number(4), month      number(2), empno number(5), cost_center number(3) insert into a values(2003, 10, 1034, 102); insert into a values(2003, 10, 1034, 102); insert into a values(

  • Collapsed Data Center Tier - Best Practice

    Hey guys, I'm working with a company who's doing a Data Center build-out. This is not a huge build out and I don't believe I really need a 2 tier design (access, core/aggregation). I'm looking for a 1 tier design. I say this because they only really

  • Status of the screen remains 'Modified/Active'  - How to resolve this

    Hi All,      In a standard screen I want to makea  field as mandatory.      I didnt find any exits. So I got the access key for that program and made     'Input property' as 'Required'.      When I activate that screen and its flow logic the status r