LMS 3.0.1, RME 4.1.1 - Inventory Collection Status displays too many device

Running LMS 3.0.1 with RME 4.1.1 on a Windows box. On the Inventory Collection Status screen I see the following:
Inventory Collection Status No. of Devices
Inventory Collected: 1246
Inventory Never Collected: 0
Inventory Recently Failed: 34
Total 1246
The problem with this is that I only have 668 devices. Is this just a cosmetic issue?

Assuming you're not integrated with ACS, then yes.  If integrated with ACS, some of the devices may not be authorized.  You will need to check your ACS configuration to make sure all devices in LMS are known to ACS and that your user (and the System Identity User) is authorized to manage them.

Similar Messages

  • LMS 3.2 - RME 4.3.1 Inventory Collection never stops (Job Result = pending)

    Hello all,
    with our LMS-System running on Solaris 10 we have the following problem:
    - Inventory Collection never stops after starting
    - This can be seen with all devices or 1 device selected
    - Config-Mgmt is working
    - After re-init of RME-DB the problem persists
    In Logfile (IC_Server.log) no problems are shown.
    In Job-Logfile only the collection request is shown.
    Any help is appreciated
    Thanks for your feedback
    Lothar

    Hi Joe,
    with further troubleshooting this problem I discoverd the following.
    - Having problems with inventoring certain Cat4000 we requested patch for Bug-ID CSCtb16925 (LibInventory.zip-File).
    - Replacing this file with the old one or installing the newest IDU for RME the problem was solved.
    It seems that the LibInventory.zip file given with Bug-ID CSCtb16925 is somewhat buggy (maybe in context with device-number) greater
    than 1000.
    Thanks for your support.
    Lothar

  • LMS 3.2 RME 4.3.1 Inventory collection failing for switches

    I have 6 switches that inventory is failing for.  They do run the 12.2(33)SXI3 software but I have the CSCtb16925-1.0  patch installed.  I've tried to increase the SNMP timeout for the devices but they still fail.
    Ideas?
    Chris Jasztrab

    You did not properly increase the SNMP timeout.  Go to RME > Devices > Device Management > RME Devices, and edit the attributes of the device in question.  Perform an inline edit.  Click on the device name, then change the existing SNMP timeout value to 10.  Then save your changes, and apply them on the previous screen.  Then inventory collection should work.

  • RME 4.3.1 Inventory collection failing for cisco 3925

    Hi,
    I've a customer having LMS 3.2 and RME 4.3.1. He has 14 Cisco 3925 routers out of which inventory collection for 2 fails.
    Router IOS is: c3900-universalk9-mz.SPA.150-1.M.bin".
    Can someone suggest what might be going wrong? Attached is the  IC_Server log file for reference.
    Thanks in advance,
    inner_silence

    Hi,
    Here are the exception found from the log :-
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,729,Exception for device 10.103.251.12 is
    java.lang.reflect.InvocationTargetException
        at sun.reflect.GeneratedMethodAccessor12.invoke(Unknown Source)
        at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
        at java.lang.reflect.Method.invoke(Method.java:585)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:719)
        at java.lang.Thread.run(Thread.java:595)
    Caused by: com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
        at com.cisco.nm.xms.xdi.pkgs.LibInventory.EnergyWise_HelperMethods.getDeviceEnergyWise(EnergyWise_HelperMethods.java:72)
        at com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.EnergyWiseAGI_ENERGYWISE_Mib.g$eval(EnergyWiseAGI_ENERGYWISE_Mib.java:51)
        at com.cisco.nm.xms.xdi.ags.EnergyWiseAGI.g$eval(EnergyWiseAGI.java:21)
        at com.cisco.nm.xms.xdi.SdiEngine.initAndEvalAGIs(SdiEngine.java:383)
        at com.cisco.nm.xms.xdi.SdiEngine.request(SdiEngine.java:309)
        at com.cisco.nm.xms.xdi.SdiEngine.getDevRepr(SdiEngine.java:302)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:539)
        ... 1 more
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,761, Collection failed for the device : 63
    com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
    Kindly check if the your device is running the required IOS on the device as per the device supported list :-
    http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/3.2/device_support/table/lms32sdt.html
    There are two 3925 listed with different versions :-
    Cisco 3925 Integrated Services Router   --> 1.3.6.1.4.1.9.1.1042  --> 15.0(1)M [RME]. if this is your device then upgrade to
    3925 to 150-1.M2
    and
    Cisco 3925E Integrated Services Router  --> 1.3.6.1.4.1.9.1.1144 --> 15.1(1)T
    Thanks,
    Gaganjeet
    If this post answers your question, please click the "Correct Answer" button

  • Inventory Collection problem for RME 4.3.1 LMS 3.2

    I recently upgraded from LMS 3.1 to LMS 3.2 and RME v 4.3.1. I have problems with the inventory collection. It will start scanning, but stops after approximately 10 devices. The rest of them will have a pending state. If I stop the collection job and start it again none (0) devices will be scanned. If I restart the ICServer it will result in the first option. That is, it will scan only 10 devices and then stop. I have extended the SNMP timeout to 30 secs and zero retries. Any suggestion would be appreciated

    I have read through the dump and cant find anything in particular. Another discovery I've made is that the SNMP walk of an unsuccessful device takes 10 times longer than a successful device. An inventory job on a unsuccessful device only goes into pending and the job never starts.

  • LMS 3.2 with RME 4.3.1 not Archiving configuration

    HI ,
    I am facing problem in Ciscoworks in Fetching config Archieve from Cisco ASA-5510 Adaptive Security Appliance . I am using LMS 3.2 and RME 4.3.1
    SSH is enable in the device, and from LMS server I am able to connect through Putty. Also from Management station to Device it showing SSH is up for both version. But from RME its failing Its giving below mentioned error
      Device: COGINHYDGCBDFHRTF1       Status:   Failed
    *** Device Details for COGINHYDGCBDFHRTF1 ***
    Protocol ==> Unknown / Not Applicable
    Selected Protocols with order ==> SSH,Telnet,TFTP,RCP,SCP,HTTPS
    Execution Result:
    RUNNING
    CM0151 PRIMARY RUNNING Config fetch failed for COGINHYDGCBDFHRTF1 Cause: Couldnot enter ENABLE Mode from USER Mode on 10.241.44.220.TELNET: Failed to establish TELNET connection to 10.241.44.220 - Cause: Connection refused.
    Action: Check if protocol is supported by device and required device package is installed. Check device credentials. Increase timeout value, if required.
    I have tried from LMS server by telneting to port 22, its giving below output------SSH-1.99-Cisco-1.25
    When I have tried to test device credentials for SSH and SSH Enable mode, then below output I am getting. SSH remains blank status.
    Device Name
    SSH
    Enable
    by SSH
    1.
    COGINHYDGCBDFHRTF1
    Did Not Try
    Pls help to resolve this.

    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin-top:0in;
    mso-para-margin-right:0in;
    mso-para-margin-bottom:10.0pt;
    mso-para-margin-left:0in;
    line-height:115%;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;}
    ],DEBUG,[Thread-778],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Returning from Session.send('terminal width 0
    [ Thu Oct 28  15:02:28 GMT+05:30 2010 ],DEBUG,[Thread-778],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,in trimPrompt(), prompt == 'ASA-F1# '
    [ Thu Oct 28  15:02:28 GMT+05:30 2010 ],DEBUG,[Thread-778],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,printStackTrace,51,stacktracecom.cisco.nm.lib.cmdsvc.CmdSvcException: Unhandled SSHv2 message: SSH_MSG_CHANNEL_REQUEST(98)
                    Channel ID: UInt32[ 0 ]
                    Channel Request Type: exit-status
                    Want Reply: true
                    Timeout (msec): 0
                    Exit Status: UInt32[ 0 ]
    What i deduce from this output is may be "ter width 0" is un-authorised for the user or is not supported by the particular code that you are currently running in the box.
    Best Regards // Rajiv

  • LMS 3.2 Inventory collection - Job timeouts after ~5h, all devices "Not attempted"

    Hello All,
    We have a strange problem with LMS 3.2 regarding Inventory Collection.
    This problem started immediatelly after the LMS installation/upgrade (LMS 3.2 was installed on a new server, and LMS 2.6 database migrated to it).
    All Jobs finish as failed, with all devices "not attempted".
    Job hangs for a five and a half hours and then reports failed status.
    The symptoms are the same for scheduled jobs and manually created jobs.
    I also have opened a TAC case, but it seems that nothing relevant can be found in the IC_Server.log.
    Also, according to a packet capture, it seems that LMS does collect SNMP data from devices after a job is started...
    We tried to upgrade RME 4.3.0 to 4.3.1.
    One Job immediately after the upgrade was succesful (Inventory was collected for manually selected device), but the next day all Inventory Jobs were failing again with the same symptoms...
    Does anyone have a sugestion where to look for a problem trace?
    Thanks in advance!
    Ragards,
    Jasmina

    Hi Jasmina ,
    Please chech the Existing MDF pacakge :
    go to common service > software center > device update >>> check the checkbox for Cisco works common service   and click on check for updates
    --if there is an Update , please upgarde the MDF version..
    --Similarly look for any Available Device Pacakges update for RME , if there are Upgarde all the Device Pacakages ....
    --After all of the above Task is done , Now re-run the Job and it still fails then share the IC_server.log  again..
    Thanks--
    Afroj

  • RME 4.31 inventory collection failed on 122-33SXI3

    Hi
    I have the same issue with IOS 122-33 SXI3  running on 6513.
    RME unable to collect the inventory details eventhough updated to LMS 3.2 .
    RME version : 4.3.1
    Is any workaround to solve this issue on LMS 3.2
    Regards
    Dileep

    Hi Clarke,
    I am also facing the similar issue with IOS 12.2(33) SXI1, the Core Switches are in VSS mode. Inventiry collection shows failed for these devices. I am using LMS 3.1 with the following submodule versions:
    Name
    Version
    License Status
    Size
    CiscoWorks Common Services
    3.2.0
    Licensed
    Not applicable
    Campus Manager
    5.1.0
    Purchased
    5000
    CiscoView
    6.1.8
    Licensed
    Not applicable
    CiscoWorks Assistant
    1.1.0
    Licensed
    Not applicable
    Device Fault Manager
    3.1.0
    Purchased
    5000
    Internetwork Performance Monitor
    4.1.0
    Purchased
    5000
    Integration Utility
    1.8.0
    Licensed
    Not applicable
    LMS Portal
    1.1.0
    Licensed
    Not applicable
    Resource Manager Essentials
    4.2.0
    Purchased
    5000

  • Inventory Collection Failure with LMS 3.2

    Hi,
    I've been running LMS 3.2 with RME 4.3.1.
    Inventory Collection fails while trying to collect data from 7825I Media Convergence Servers running Call Manager 6.1.
    It fails with the following error:
    RICS0001:Internal Error,unable to process the collected data from the device.
    I have tried deleting and adding the device again, but with no effect.
    The Call Manager server has ip 192.168.5.5, here it is the IC_Server.log attached.
    Looking at the log, I see there is some kind of database error, but I don't know how can be avoided.
    Any suggestions?
    Regards,
    Velin

    I have removed the Call Managers from RME, and then re-added them again.
    After that I started a inventory collection job but it failed again with the same error. I've tried some times with the inventory job but it fials every time.
    I read about the bug you've mentioned and it is advised to patch the RME. Since i'm running the latest version, what can i do?

  • RME 4.3, Inventory Collection doesn't work for 6500

    I have a issue with Inventory collection for 6500 devices running IOS 12.2.33 SXI1, fails with a message, "device collection failed"
    From IC_Server log i could see SNMP Request timeout exception, so increased SNMP timeout to 10  under device attributes for the device but still it fails.
    attacehd is the extract from IC_Server log.
    Could anybody help me on this? Thanks

    You have not increased the timeout properly.  You need to go to RME > Devices > Device Management > RME Devices, and edit the attributes for the required device.  Select the device from the list in the left-hand pane to pre-populate the current attributes.  Then increase the SNMP timeout to 10, and save the changes.  On the previous screen, you will need to APPLY those changes before the 10 second timeout will take effect.

  • RME 3.2 Inventory Collection Failure with error

    Hi,
    Inventory collection fails with error is "Timed out. Make sure that ICServer is running”. But the ICServer process is running. I enabled debug on could see the following in the IC_Server.log which I'm not sure if it indicates any issues.
    I can find the devices in DCR and the devices are classified as Normal in RME.
    Series of following message for all the devices
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.Request,115,Removing device 181from request 1255347128972
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,163,Removing, 175
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,171,got device, 175
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.Device,51,Removing request 1255347128972 for device 175
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,177,Removed2 dev, 175from Priority of the ENUM is : 0
    then,
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,89,Adding Device :175
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.Device,46,Adding request 1255347128973 for device 175
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,142,Found dup device in queue: 175
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.Request,75,Adding device 175 to request 1255347128973
    and then the below messages
    DEBUG,[Timer-0],com.cisco.nm.rmeng.inventory.ics.threadpool.ThreadPool,69, Timer Tasks Run method is called.
    DEBUG,[Timer-0],com.cisco.nm.rmeng.inventory.ics.threadpool.ThreadPool,69, Timer Tasks Run method is called.
    DEBUG,[Timer-0],com.cisco.nm.rmeng.inventory.ics.threadpool.ThreadPool,69, Timer Tasks Run method is called
    I highly appreciate any help on this. Thanks

    The ICServer process could have locked up which means a full thread dump will be required to see why this is happening. Open a TAC service request, and they can walk you through getting this.

  • LMS 3.1 Inventory Collection fails

    I have the same problem as the following post:
    https://supportforums.cisco.com/thread/176673?tstart=0&viewcondensed
    Also, LMS fails inventory collection every time.  I click on the "failed" link from LMS Portal, but the page never comes up detailing why it has failed.  This is after I fixed an issue with group policy overwriting the "Logon as batch" setting for casuser.  Everything appeared to be up and running normally again, when I noticed the next day that inventory polling/collection is failing.  pdshow attatched.
    The following error message continues to show up in the rme_ctm.log file:
    [ Tue Feb 22  07:40:55 CST 2011 ] URN_NOT_FOUND : urn "JRM" : Not found !!
    The last entry in the CTMJrmServer.log file is:
    [ Thu Feb 10  10:52:55 CST 2011 ],INFO ,[main],com.cisco.nm.rmeng.jrmwrapper.server.CTMJobManagerServer,publishDaemonOk,99,Called CreateReady file. Return Value 0
    I've been blindly trying to chase this down and getting nowhere.

    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin:0in;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;}
    Hi ,
    Great ..
    The issue was this Port was blocked 47001, which was blocked . what we did will skip that Port and
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0in 5.4pt 0in 5.4pt;
    mso-para-margin:0in;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;}
    the ctmregistry should have EssentialsDM on a new port, and the conflict should not reoccur.
    Thanks--
    Afroj

  • LMS 4.2.1 upgrade from 4.0.1: can't display job information : http 404 error

    HI,
    Since customer has upgraded from 4.0.1 to 4.2.1, he can't display job information when he select job number.
    He has http 404 error.
    He has same error when he want to see threshold configuration:
    Menu Monitor>Fault Monitor > threshold setting
    We noticed that there is many files on C:\Program Files (x86)\CSCOpx\files\rme\dcma\devfiles.
    We can see that CollectionSummary has 4 collector name which are loading status:
    Configuration-> Dashboard -> Configuration
    - Inventory collection
    - Config archive
    - EnergyWise
    - Fault Discovery
    Many thanks for your help,
    Elisabeth

    Doesn't look like it was tested.  Checking why ...
    Zach

  • LMS 3.2 Inventory Collection Failing

    Inventory collection is failing without any detailed error information.  I'm attaching IC_Server.log. Example device is 10.79.82.250, towards end of log. I see these messages but not sure what to make of them. SNMP communication is ok and walk of system mib is ok.
    [ Fri Dec 11  09:37:29 EST 2009 ],INFO ,[Thread-21],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventorySatellite.SatelliteHelperMethods,isVirtualMibSupported,32,
    cisco virtual mib,exception while interpreting cvsChassisMode value
    com.cisco.nm.lib.snmp.lib.SnmpValueException: Illegal Access. NoSuchObject being accessed as Integer.
    [ Fri Dec 11  09:37:29 EST 2009 ],INFO ,[Thread-21],com.cisco.nm.rmeng.util.logger.XDILogger,77,com.cisco.nm.xms.xdi.pkgs.SharedInventorySatellite.SatelliteHelperMethods,isVirtualMibSupported,32,
    cisco virtual mib,exception while interpreting cvsChassisMode value
    com.cisco.nm.lib.snmp.lib.SnmpValueException: Illegal Access. NoSuchObject being accessed as Integer.

    Go to RME > Devices > Device Management > RME Devices, and edit the device attributes for this device.  Change the SNMP timeout to 10 seconds.  Make sure you apply the changes you make.  After doing that, inventory collection should work.

  • RME 4 - Inventory Collection Failure

    I am getting the following RME inventory collection error on 4 devices.  These 4 devices were recently added to the network and were all attached to a new radius server.  I have tested AAA to the 4 switches and am confident that radius is working as intended.
    The devices are a mix of 2950 and 3550 switches.
    Here is the error.
    RICS0001:Internal Error,unable to process the collected data from the device.
    Thanks in advance.

    In that case, this is probably CSCsk65355 which should be fixed in 4.1.1.  However, 4.1.1 suffers from CSCsm97530.  So I would suggest to first upgrade to RME 4.1.1.  If you continue to see this, then you can contact TAC and apply patch for CSCsm97530 over 4.1.1.

Maybe you are looking for

  • Error message when loading windows

    I have been using windows on my mac for months and all of the sudden I am getting an error message when I start windows. No matter what I do(report or just close it), it comes up every time I start windows. There is no code telling me what kind of er

  • Error in RTW for file content conversion

    Hi, In my scnario there are one header,0..unbounded master,0..unbounded detail,one trailer. proxy to file scnario. when the file is finally generated that is for particulam one employee. mapping is successful. what shoul i do for when 2 employee reco

  • Send message to WebSphere MQ resource adapter - how?

    Hi, has anybody a working sample how an Weblogic EJB can write to an MQ queue via the WebSphere MQ resource adapter? http://publib.boulder.ibm.com/infocenter/wmqv6/v6r0/index.jsp?topic=/com.ibm.mq.csqzaw.doc/uj40010_.htm I took Adrian Cole's sample f

  • I have a HP notebook running Vista. How do I network it to my HP all in one 6210?

    I've actually installed the printer on my laptop and got it networked to my Dell desktop where my HP Officejet is installed and shared.    I get documents into the Printer que, but it comes up as "error" and won't print.   So my laptop recognizes it

  • Seeking advice for a wookiee video person...

    I'm shooting alot of videos lately. Typically - they just sit in a folder when I transfer via usb to my dell laptop (sorry I don't have a Macbook pro quite yet!). I know there is Windows Movie Maker and some other "free" junk out there. I see Camtasi