LMS 3.2 and Catalyst 4500 WS-X4648-RJ45-E module card
Hi all,
I have a rpoblem with a specific client with LMS 3.2. We are using LMS 3.2 on Windows 2008 and everything seem to be working OK. The issue is in the CiscoView with the 4500 switches. CiscoView can see the supervisors on all 4500 switches (6); but cannot see the switchcards when the switchcards are WS-X4648-RJ45-E. Find the sh inv output below:
CSR-D1#sh inventory
NAME: "Switch System", DESCR: "Cisco Systems, Inc. WS-C4507R-E 7 slot switch "
PID: WS-C4507R-E , VID: V01, SN: FOX1152GKR1
NAME: "Clock Module", DESCR: "Clock Module"
PID: WS-X4K-CLOCK-E , VID: V01, SN: JAE120354DD
NAME: "Linecard(slot 1)", DESCR: "10/100/1000BaseT (RJ45) with 48 10/100/1000 baseT "
PID: WS-X4648-RJ45-E , VID: V01, SN: JAE14410NLT
NAME: "Linecard(slot 2)", DESCR: "6 Dual media SFP or 10/100/1000BaseT (RJ45)V voice power ports (Cisco/IEEE)"
PID: WS-X4506-GB-T , VID: V05, SN: JAE120351NC
NAME: "Linecard(slot 3)", DESCR: "Supervisor 6-E 10GE (X2), 1000BaseX (SFP) with 2 10GE X2 ports"
PID: WS-X45-SUP6-E , VID: V01, SN: JAE120576HG
NAME: "TenGigabitEthernet3/1", DESCR: "10Gbase-LRM"
PID: FTLX1341E2-C1 , VID: A , SN: FNS1352175M
NAME: "TwinGig Converter 3/2", DESCR: "TwinGig Converter Module"
PID: 800-27645-01 , VID: A0 , SN: CAT1147H2WK
NAME: "Linecard(slot 4)", DESCR: "Supervisor 6-E 10GE (X2), 1000BaseX (SFP) with 2 10GE X2 ports"
PID: WS-X45-SUP6-E , VID: V07, SN: JAE14080NL2
NAME: "TwinGig Converter 4/2", DESCR: "TwinGig Converter Module"
PID: 800-27645-01 , VID: A0 , SN: CAT1147H2BV
NAME: "Linecard(slot 7)", DESCR: "10/100/1000BaseT (RJ45) with 48 10/100/1000 baseT "
PID: WS-X4648-RJ45-E , VID: V01, SN: JAE14420A2F
I have updated the s/w to 12.2(53) SG1 with no luck.
Any ideas?
Hi Nicos,
I have exactly the same issue with LMS 3.2 CiscoView under Windows 2003 and catalyst switch 4506-E.
4506-E are in IOS 12.2(53)SG2.
I installed latest 4500IOS V 19.0 ciscoview device package without success.
Did you fix your problem ?
Similar Messages
-
I am working on a Catalyst 4510(R) with a Supervirsor Engine: WS-X4516, IOS version 12.2(18)EW2. According to the Cisco Doc: http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120t/120t1/easyip2.pdf The DHCP Server is not supported on my Switch. But I am able to configure the database parameters. Where can I verify the real answer?
It is helpful to use tools like the Feature Navigator and to read release notes for the particular version of the code being used and to read other documentation on the Cisco site. But I believe that if you really want to verify the real answer what you should do is to configure the DHCP parameters and connect a PC that is configured to use DHCP. If it gets an address then the documentation and Feature Navigator need to be updated. If the PC does not get an address then it looks like the documentation was correct.
I believe that ultimately there is nothing better to help understand what works than getting gear into the field and see what it really does for various features.
HTH
Rick -
Lms 3.2 and WS-SVC-AGM-1-K9, error: unsupported card
I have lms3.2 to manage cisco 6509, other linecard recognise by Lms but WS-SVC-AGM-1-K9 card cant recognise by lms.
It display "unsupported card".
Pls help me.hi David,
Thank you for response.
/* Style Definitions */
table.MsoNormalTable
{mso-style-name:"Table Normal";
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:"";
mso-padding-alt:0in 5.4pt 0in 5.4pt;
mso-para-margin:0in;
mso-para-margin-bottom:.0001pt;
mso-pagination:widow-orphan;
font-size:10.0pt;
font-family:"Times New Roman","serif";}
We have updated from Cat6000IOS.cv50.v30-2 to Cat6000IOS.cv50.v31-2
and we still get the error. -
Nexus 5548 and Define static route to forward traffic to Catalyst 4500
Dear Experts,
Need your technical assistance for the Static routing in between Nexus 5548 and Catalyst 4500.
Further I connected both Nexus 5548 with Catalyst 4500 as individual trunk ports because there is HSRP on Catalyst 4500. So I just took 1 port from each nexus 5548, make it trunk with the Core Switch (Also make trunk from each Switch each port). Change the speed on Nexus to 1000 because other side on Catalyst 4500 line card is 1G RJ45.
*Here is the Config on Nexus 5548 to make port a Trunk:*
N5548-A/ N5548-B
Interface Ethernet1/3
Switchport mode trunk
Speed 1000
Added the static route on both nexus for Core HSRP IP: *ip route 0.0.0.0/0 10.10.150.39 (Virtual HSRP IP )*
But I could not able to ping from N5548 Console to core Switch IP of HSRP? Is there any further configuration to enable routing or ping?
Pleas suggestHello,
Please see attached config for both Nexus 5548. I dont have Catalyst 4500 but below is simple config what I applied:
Both Catalyst 4500
interface gig 3/48
switchport mode trunk
switchport trunk encap dot1q
On Nexus 5548 Port 1/3 is trunk
Thanks,
Jehan -
We have a 1000v switch uplinked to nexus 5K and Catalyst 4500 switches. I can see all the VEMs(ESX servers) connected to the nexus 5K uplink switch and everything seems working fine. However, I am not able to see the VEMs uplinked to Cisco Catalyst 4500 switch. The "show Module" command shows all VEMs connected to the nexus 5K uplink switches but not the Catalyst 4500 switches.The log file on the 1000V shows the following:
7 09:36:21 NX-1K-100 %VMS-5-DVS_HOSTMEMBER_INFO: A host with name=[IP ADD. OF ESX SERVER] and uuid=[34393232-3035-3255-5839-3430303
03537] is added to the dvs. The host is not found as a module in the VSM configuration.
If anyone have run into similar situation, plpease let me know how you handled it.
ThanksHi bharga,
I did all the checking....
1) all important VLANS including the control vlan are not blocked (No STP issue)
2) The Nexus 5K and the 4500 switch are in layer layer 2 ( They are not directly connected but are in layer two domain or no hop between them)
3) the ESX Server hosting the VSM is connected to the Nexus 5K
Here is some of the show commands that i run on the 4500 switch that is connects the ESX server to the rest ofd the network:-
Catalyst-4500#sh spanning-tree interface gigabitEthernet 1/38
Vlan Role Sts Cost Prio.Nbr Type
VLAN0073 Desg FWD 4 128.38 P2p Edge
VLAN0074 Desg FWD 4 128.38 P2p Edge
VLAN0151 Desg FWD 4 128.38 P2p Edge
VLAN0152 Desg FWD 4 128.38 P2p Edge
VLAN0153 Desg FWD 4 128.38 P2p Edge
VLAN0165 Desg FWD 4 128.38 P2p Edge
Catalyst-4500#sh mac address-table interface gigabitEthernet 1/38
Multicast Entries
vlan mac address type ports
-------+---------------+-------+--------------------------------------------
73 ffff.ffff.ffff system Gi1/32,Gi1/38,Gi1/42,Gi1/45
74 ffff.ffff.ffff system Gi1/38,Gi1/41,Gi1/45
151 ffff.ffff.ffff system Gi1/3,Gi1/5,Gi1/6,Gi1/7,Gi1/9,Gi1/10,Gi1/11
Gi1/12,Gi1/14,Gi1/16,Gi1/17,Gi1/18,Gi1/19
Gi1/21,Gi1/22,Gi1/23,Gi1/25,Gi1/26,Gi1/27
I still don't see the VEM connected to port 1/38 of this switch on my nexus 1000v switch. The configuration file show exactly how many VEMs I have as shown below:
Nexus-1000v# sh running-config
host vmware id 34373030-3635-3255-5830-303630344
vem 4
host vmware id 34373030-3635-3255-5830-313130313
vem 5
host vmware id 34373030-3635-3255-5830-303630344
vem 6
host vmware id 34393232-3035-3255-5839-3134303537
vem 7
host vmware id 34373030-3635-3255-5830-313130313
vem 8
host vmware id 33393138-3335-5553-4539-31314e3438
vem 9
host vmware id 34393232-3035-3255-5839-3339303646
vem 10
host vmware id 34393232-3035-3255-5839-3430303035
vem 11
host vmware id 34393232-3035-3255-5839-3339303646
But the show module command on the nexus 1000v shows only those VEMs coonected to the Nexus 5K switches and not those connected to the Catalyst 4500 switches.
the uplink por-profile confguration on the Nexus 1000 V :
vmware port-group
switchport mode trunk
switchport trunk native vlan 74
switchport trunk allowed vlan 73-74,151-153,165,180,811,813,815,817-822,824,826-831
channel-group auto mode on sub-group cdp
no shutdown
system vlan 74,180,811,819-821
state enabled
the corresponding interface on the 4500 switch :
interface GigabitEthernet1/38
switchport trunk encapsulation dot1q
switchport trunk native vlan 74
switchport trunk allowed vlan 73,74,151-153,165,180,811,813,815,817-822,824
switchport trunk allowed vlan add 826-831
switchport mode trunk
mtu 9000
spanning-tree portfast trunk
I really appreciate in finiding out why I can't see the VEM (ESX Servers) connected to the 4500 switches.
Thanks -
Connecting FI to Catalyst 4500 switch
Hello Experts,
We are planning to connect Cisco UCS Fabric Interconnect to (WS-X4648-RJ45-E) module on 4500 Catalyst Switch.
What SFP module do we need to install on the Fabric Interconnect for this connection ?
Thank you,
MohammadHi Mohammad,
Following is the URL to the datasheet for the fabric interconnects:
http://www.cisco.com/en/US/prod/collateral/ps10265/ps10276/data_sheet_c78-524724_ps10280_Products_Data_Sheet.html
It has a section for all the supported SFPs on the FIs.
Hope this helps!
./Abhinav -
Catalyst 4500 Ethernet and fibre channel passthru
dear sir,
anyone have any idea / documentation showing that the belows device 1.) & 2.) can support Ethernet and fibre channel passthru ? thanks.
1.) WS-X4424-GB-RJ4 (Catalyst 4500 24-port 10/100/1000 Module (RJ45)
2.) WS-X4306-GB (Catalyst 4500 Gigabit Ethernet Module, 6-Ports (GBIC)You're welcome. Check below for the module info. And there is description about support of fibre channel passthru.
http://www.cisco.com/en/US/products/hw/switches/ps4324/products_data_sheet0900aecd802109ea.html
You can also seach Cisco web for more info.
Hope this helps. -
Catalyst 4500-X, VSS, and SVI
Hello, everybody!
I have a proyect to implement the feature VSS, with two catalyst 4500-X, it will be the layer Core/Distribution.
So, I want integrate in the catalyst 4500X, Inter vlan routing (SVI) and vtp domain, in the layer access, we´ll have SW 3750-X with PoE.
Is possible configure SVI in my catalyst 4500-X. to separate traffic across VLANs. and the routing will be in the 4500X too. ???
My customer does not have sufficient space to mount the serie 4500E in the Rack, so he prefer the 4500-X.
Help me!
Thanks!
RegardsHi,
Is possible configure SVI in my catalyst 4500-X. to separate traffic across VLANs. and the routing will be in the 4500X too. ???
Yes, there is no different between a VSS pair and non-VSS when it comes to SVI and inter-vlan routing. It works the same way as if the 4500-X ware separate.
HTH -
LMS 3.1 and CiscoView 6.1.8 not swhowing 10Gb modules
Hi!.
We´ve got a CiscoWorks (LMS 3.1) with CV 6.1.8 and it doesn´t display the new installed 10Gb (X2-10Gb-SR=) modules in the Catlyst 6509E chassis and Catalyst 3750E, what can I do to fix it?
Thanks.Hi ,
Upgarde the LMS to LMS 3.2 and then check the issue..
Download link for LMS 3.2:
https://cisco.mediuscorp.com/market/networkers/productView.se.work?/nxt/rcrs/proieidentity/=17651
Note : you do not need a new liense for LMS 3.2 , your existing license will just work fine
Thanks
Afroj -
Trunking on Nexus 5000 to Catalyst 4500
I have 2 devices on the each end of a Point to Point. One side has a Nexus 5000 the other end a Catalyst 4500. We want a trunk port on both sides to allow a single VLAN for the moment. I have not worked with Nexus before. Could someone look at the configurations of the Ports and let me know if it looks ok?
nexus 5000
interface Ethernet1/17
description
switchport mode trunk
switchport trunk allowed vlan 141
spanning-tree guard root
spanning-tree bpdufilter enable
speed 1000
Catalyst 4500
interface GigabitEthernet3/39
description
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 141
switchport mode trunk
speed 1000
spanning-tree bpdufilter enable
spanning-tree guard rootThanks guys, we found the issue. The Catalyst is on my side and the Nexus is on the side of the hosting center. The hosting center moved his connection to a different Nexus 5000 and the connection came right up. We dropped the spanning-tree guard root.
It was working on the previous nexus when we set the native vlan for 141. So we thought it was the point to point dropping the tags.
The hosting center engineer this it might have to do with the VPC Peer-Link loop prevention on the previous Nexus.
Anyway it is working the way we need it to. -
WS-X4306-GB - Catalyst 4500 6-port GBIC Module & FC Tape Libraries
WS-X4306-GB - Catalyst 4500 6-port GBIC Module & FC Tape Libraries
I have several Tape Autoloader Libraries from Dell which have Fibre Channel interfaces. I have loop switches that these connect to today. I also have a Catalyst 4506 with a WS-X4306-GB - 6-port GBIC Module. I would like to use the X4306 as a loop switch. Some of the libraries can also connect via point-to-point FC.
Can this be done? If yes, how do I start in making this happen?
Thank You.Sorry but the Catalyst 4500 does not support Fibre Channel connections on the WS-X4306-GB (or on any card). It's strictly an Ethernet switch. Reference
To mix and match Ethernet and FC interfaces, you'd have to be on a new platform like the Nexus 5k series - specifically the UP (Unified Port) variants. -
QoS trust dscp or cos on catalyst 4500
We have a 4510R with Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software cat4500e-UNIVERSALK9-M), Version 03.05.02.E RELEASE SOFTWARE (fc1).
I want use qos trust dscp or qos trust cos on the interface conected to other cisco switch or wlan controller.
The current IOS version, do not support qos trust dscp:
SW(config)#interface gi10/16
SW(config-if)#qos tr
SW(config-if)#qos trust ?
device trusted device class
extend Extend trust through a connected device
SW(config-if)#qos trust device ?
cisco-phone Cisco IP Phone
cts Cisco-telepresence
ip-camera Cisco video surveillance camera
media-player Cisco Digital Media Player
SW(config-if)#qos trust device
What is the software that I need for this?. I tried with command lookup tool but the cat4500 do not appears.That is even new for me.
I did a search and found that, now a days you no longer have to provide the Trust DSCP command, it is by default trusted.
Went through this White Paper and excerpts are below:
http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4500-series-switches/white_paper_c11-539588.html
The answer to your question comes from the following excerpt :-
"Previously supervisor engines relied on “port trust” to classify traffic; however, this does not fall into the MQC CLI construct. MQC provides a more flexible capability, i.e. all traffic is trusted by default, an administrator can change this trust state using a policy map. Another difference is the “internal DSCP” value used within the switch to place packets in the proper queue.
Cisco Catalyst 4500E Supervisor Engines do not use “internal DSCP”; rather, it relies on explicit matching of QoS values using class maps so that packets can be placed in the correct queue.
Also, note that there is no specific priority queue: it is not queue 3 or queue 1. The priority queue is simply configured within a class; therefore, it is not tied to a specific queue. One final difference is that of classification. Cisco Catalyst 4500E Supervisor Engines provide sequential classification rather than parallel. This allows the network administrator to classify traffic at egress based on the ingress markings. These markings can be done unconditionally, using a policer or using a table map. Based on these changes, QoS CLI will now be more contiguous on the Supervisor Engines as it will now have standard Cisco MQC CLI, making configuration management much simpler"
HTH,
Please rate all helpful posts.
Regards -
Hi,
I have an issue with a Catalyst-4500 (4507R-E, ipbase, 12.2.46SG), that is running very hi CPU since some days:
By investigating, I observed a couple of processes that are realy CPU-consuming:
I don't know where to look ...
Some help and/or some suggestion ?
Best regars,
ClaudioTwo good resources for troubleshooting high CPU on the 4K
High CPU Utilization on Cisco IOS Software-Based Catalyst 4500 Switches
http://www.cisco.com/c/en/us/support/docs/switches/catalyst-4000-series-switches/65591-cat4500-high-cpu.html
Troubleshooting High CPU on the Catalyst 4500-E Series Switch
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/troubleshooting/cpu_util.html
HTH
Luke -
Catalyst 4500, scp, rcp
Does anybody know is it possible to set up a remote access to the Catalyst 4500 series switch thru the rcp or scp protocol? I want to start commands on the remote unix server. Like unix# scp -i identity -B acl.file user@catalyst:system:running-config or unix# rcp acl.file user@catalyst:system:running-config, where acl.file is the file with access-list. It's important to start commands on the remote server, not on the switch. Thanks for any advice.
Hello,
I just tried this on a Cat 4500 using tftp, and successfully changed its hostname, and added a new ACL.
The same should be true for rcp and scp.
Just remember to put "end" as the last line of the file, otherwise you will get a %PARSER-4-BADCFG: Unexpected end of configuration file message (but it still works).
This was tried on Version 12.2(25)EWA4.
Hope this helped,
Michael. -
SFP-10G-ZR support on Catalyst 4500 SUP6E
Hello,
is the SFP-10G-ZR supported on the SUP6-E with the OneX converter?
BR
O.GEnd-of-Sale and End-of-Life Announcement for the Cisco Catalyst 4500 Supervisor Engine 6-E
The chances of your SE submitting the PER is now ZERO. You'll be forced to upgrade to Sup7E.
Maybe you are looking for
-
Replication Issue for ECC BP to CRM BP
Hello Experts, I am trying to Create a BP in ECC with transaction BP, but whenever i save the BP in ECC, the BDOC gets stuck in CRM with the error message that 'Grouping CUBP does not exist', Everything was working fine before, but recently we had cr
-
HI GURU'S Presently we are maintianing TDS,Surcharge,Ecess and Higher education cess in the dedction. It means 4 TDS line item I get at the time of the invlice or payment. And When i am running J1INCHLN I am getting only 3 line items. Surcharge line
-
Data not go to table?How to Resolve it?
Hi All, I created one form based upon a table.In that form i want one field value as automatic value from another table. I write the sql query to a particular field.the value comes to that form automatically.But the problem is when i submit that part
-
Post Author: Janice CA Forum: Charts and Graphs I have a report written in Crystal Reports XI that has a pie chart in the Report Header displaying counts of activity by "reason code" for a selected time period. The users have noticed that, when they
-
Help Urgent! Problems with dashboard
My iphone fell and now anything that is in the lower part of the screen doesnt work it looks fine, for example in the lower part of the screen were it says phone, mail, safari, ipod it looks perfect but I cant open it same thing happens when im typin