LMS 3.2 - RME 4.3.1 Sync archive fails

Hi,
Sync archive fails for some of my devices.
This is the message :
*** Device Details for .... ***
Protocol ==> Unknown / Not Applicable
Selected Protocols with order ==> Telnet,TFTP,SSH,RCP,HTTPS
Execution Result:
CM00139 Could not archive config Cause: Action: Verify that device is managed and credentials are correct. Increase timeout value, if required.
Check device credential is OK (Telnet + SNMP V2)
This device is Cisco Systems WS-C6009.Cisco Catalyst Operating System Software, Version 7.4(3). (sysObjectID : enterprises.9.5.39)
I have modified the "Maximum time to wait for Job Results per device (seconds):" to 240.
What could be wrong?
Thanks in advance

Resolution Summary:Checked the dcmaService.log and found the following recurring statements.
com.cisco.nm.xms.xdi.pkgs.LibCommon.common.CommonUtility,getMinSupportedVersion,406,Descr = 12.2(50)SE
[ Tue Oct 26  15:58:45 CDT 2010 ],DEBUG,[main],com.cisco.nm.xms.xdi.pkgs.LibCommon.common.CommonUtility,getMinSupportedVersion,405,suppSysId = .1.3.6.1.4.1.9.1.927
[ Tue Oct 26  15:58:45 CDT 2010
Checked that the device IOS was well above the version specified in the logs, so thought may be an issue with the device packages.
Checked the mdf version was 1.25 which came as default when we install LMS 3.2, so upgraded the mdf version to 1.45.
Still the issue didn't got solved, so upgraded the RME device packages and now the archive job was successful.
Message was edited by: Dheeraj Gera

Similar Messages

  • Sync Archive failed LMS 3.2 using TACACS

    Dear All,
    Iam using LMS 3.2. In short, there is 2 type of router, 2800series and 2900series.
    These device already join to TACACS server. When I try to sync archive I got:
    - failed on 2900series
    - successful on 2800series
    I have doing same config (credential, snmp, protocol for sync archive), for those device on ciscoworks but why I find the error??

    Usually it is essential to configure the $NMSROOT\objects\cmf\data\TacacsPrompts.ini file. As with tacacs+ Auth you can also define custom login username and password prompt, hence this file is important to be configured, only in case of Telnet not SSH.
    So just check the login prompt you get in your device when you try to do telnet and mention the same in you
    TacacsPrompts.ini file.
    Example:
    >Following is the content of TacacsPrompts.ini :
    [TELNET]
    USERNAME_PROMPT=
    PASSWORD_PROMPT=
    > Following is the username and pasword propmt for my device :
    > As per this please modify the file as :
    [TELNET]
    USERNAME_PROMPT=Username:
    PASSWORD_PROMPT=Password:
    Just save and try to run the job again for failing device.

  • Sync Archive fails for CRSs on LMS 3.1

    Hi, I've been trying to collect the configuration of some CRS-1 4-slot but it keeps on failing. These are the only devices I'm missing (out of 2,000). I've tried to tweak the timeout values but it makes no difference. The actual values are set to:
         SNMP Retry = 6
         SNMP Timeout = 90 sec
         Telnet Timeout = 120 sec
         TFTP Timeout = 60 sec
    The protocols I'm using to retrieve the configs are SSH, Telnet, and TFTP. Telnet is disabled on this devices, they use SSH v2 instead. What I get from the job details is:
    *** Device Details for 9R_MCO_NEXTENGO ***
    Protocol ==> Unknown / Not Applicable
    Selected Protocols with order ==> SSH,Telnet,TFTP
    Execution Result:
    CM00139 Could not archive config Cause: Action: Verify that device is managed and credentials are correct. Increase timeout value, if required.
    They are managed by RME, indeed and it has been able to collect their inventory. This CW is installed on Solaris 9. If I try to SSH from the console it prompts me for a password, but if I type in CW server's account password it won't log me in. Then I need to specify my username and I'm able to get access.
         # ssh 10.255.0.41 -l CISWORKS
    Does this looks like an SSH issue? Then it should be able to collect the configs by TFTP. Or are CRSs not fully supported on LMS 3.1? This devices are running IOS XR 3.6.2.
    Thanks in advance.

    This sounds to me like the credentials are misconfigured in DCR.  Go to Common Services > Device and Credentials > Device Management, and re-enter the username and password for this device.  Then see if you can archive the configuration.  The CRS-1 4-slot chassis is supported in RME 4.2.

  • LMS 3.2 RME 4.3.1 Inventory collection failing for switches

    I have 6 switches that inventory is failing for.  They do run the 12.2(33)SXI3 software but I have the CSCtb16925-1.0  patch installed.  I've tried to increase the SNMP timeout for the devices but they still fail.
    Ideas?
    Chris Jasztrab

    You did not properly increase the SNMP timeout.  Go to RME > Devices > Device Management > RME Devices, and edit the attributes of the device in question.  Perform an inline edit.  Click on the device name, then change the existing SNMP timeout value to 10.  Then save your changes, and apply them on the previous screen.  Then inventory collection should work.

  • LMS 3.2: RME failed archive with Nexus 5010

    Hi,
    LMS 3.2, RME 4.3.1, dev packages updated, Windows.
    We would like to archive the configuration of the Nexus 5010 switches. Due to authentication with Radius based on tokens we're not able to use telnet/SSH and therefore we only can use SNMP WRite in combination with TFTP.  But, this is not working at all. Other systems like 3750 works fine. Is there a difference between Catalysts IOS and nexus NXOS?
    I searched the forum and found this:
    https://supportforums.cisco.com/message/663481#663481
    upgrade to LMS 2.6, archive config not working anymore
    We ship and start a TFTP server by default on Windows.  You must have an SNMP read-write community string configured on your devices, and entered in DCR for TFTP config fetches to work.  Additionally, udp/69 must be open between device and server.
    The easiest way to troubleshoot this kind of problem is to start a sniffer trace on the LMS server (using Device Center > Packet Capture).  Filter on all traffic to one of the failing devices.  Then, run a Sync Archive job for that same device.  When it fails, the sniffer trace will indicate what the problem is
    Regards
    Ad Olsthoorn

    Hi Lavramov,
    Yes I'm quite sure, I installed the required packages acoording to the Nexus.RME431.v2-2.readme.pdf manual. the manual tell me to install the following (see also attachement).
    To install the Cisco Nexus Series Package, you must install the following dependent packages:
    - SharedDcmaSS.RME431.v2-2.zip
    - SharedInventoryMDS.RME431.v1-5-1.zip
    - SharedSwimMDS9000.RME431.v1-6-1.zip
    - SharedNetshowSS.RME431.v1-1.zip
    regards
    Ad

  • LMS 3.2 - RME 4.3.1 - Report Generator scheduled Syslog-Reports

    Hi all,
    within Report Generator in RME 4.3.1 I discovered an issue with newly added devices in scheduled Syslog Severtiy Level Summary Reports.
    Settings for the report
    - Device Selector: All Devices
    - Data Range: 24 hours
    - Schedule: daily, at xx:xxh
    Our purpose for this job is to get a daily summary of syslogs of all managed devices.
    But there seems to be a problem with the dynamic update of newly added devices to DCR and RME-Device-DB.
    The report only creates output for all managed device at timestamp of report creation, not for newly added devices.
    Is this a know bug, or is this the planned behavior?
    Any suggested workarounds/fixs are appreciated.
    Thanks a lot for your help.
    Lothar

    This is documented in the online help for the report generator, sync archive, etc. pages.
    # Group Selector — To schedule a job for dynamic group of devices.
    The job is scheduled only for the devices that are present in the selected group at the time when the job is run. The customizable group selector for jobs evaluates static groups also as dynamic during run time.

  • LMS 4.0 ASA-SSM-10 Sync archive

    Hello.
    During Sync archive for ASA-SSM-10 which is installed in ASA 5505 device I received the error:
    *** Device Details for Cisco ASA IPS ***
    Protocol ==> Unknown / Not Applicable
    Selected Protocols with order ==> Telnet,SSH
    Execution Result:
    RUNNING
    CM0151 PRIMARY RUNNING Config fetch failed for Cisco ASA IPS Cause: TELNET: Failed to establish TELNET connection to 172.26.22.32 - Cause: Authentication failed on device 3 times.
    SSH: Failed to establish SSH connection to 172.26.22.32 - Cause: Authentication failed on device 3 times.
    Action: Check if protocol is supported by device and required device package is installed. Check device credentials. Increase timeout value, if required.
    The connection to this device (ASA-SSM-10) is possible with SSH protocol with Putty and with SecureCRT. What has to be change in the LMS to sucess with Sync archive and later with changing the archive with the LMS 4.0. Thank you.

    Post the show ver of the device and we can verify if its supported or not and the OID as well.

  • CiscoWorks: Why all devices Sync archive only partially successful.

    Hi,
    Whenever we sync archive a device, its always partially successfull only,  and when we click partial successfull , below details appears. We have 4000 devices and all are only partially successful only Below details are from partial successful device, it has the vlan. dat and before it was working ok.
    *** Device Details for Device1 *** Protocol ==> Telnet Selected Protocols with order ==> SSH,Telnet,TFTP,RCP,HTTPS
    Execution Result: CM0062 Polling Device1 for changes to configuration. CM0065 No change in PRIMARY STARTUP config, config fetch not required CM0065 No change in PRIMARY RUNNING config, config fetch not required CM00 Polling not supported on VLAN RUNNING config, defaulting to fetch. VLAN CM0057 VLAN RUNNING Config fetch SUCCESS, archival failed for Device1 Cause: CM0005: Archive does not exist for Device1 Action: Verify that archive exists for device.
    Also If I goto e:\NMSROOT\files\rme\jobs\ArchiveMgmt\6523(JOBID) and then log, below is output from logs.
    [ Mon Nov 14  14:55:37 GMT 2011 ],ERROR,[main],com.cisco.nm.rmeng.dcma.jobdriver.DcmaJobExecutor,initJobPolicies,925,Could not configure Thread.
    [ Mon Nov 14  14:55:37 GMT 2011 ],ERROR,[main],com.cisco.nm.rmeng.dcma.jobdriver.DcmaJobExecutor,sendMail,1334,sendEmailMessage: Null recipient list
    [ Mon Nov 14  14:56:20 GMT 2011 ],ERROR,[main],com.cisco.nm.rmeng.dcma.jobdriver.DcmaJobExecutor,sendMail,1334,sendEmailMessage: Null recipient list
    I am getting below logs,please advice, how to resolve the issue.
    Thanks.
    I am using LMS 3.2.1

    Yes you are right that we have restore from backup and since then this problem occurs. We have uninstall the CiscoWorks from c: drive and install it on e:drive, due to high disk utilization issue on c: drive.
    I have checked the
    RME > Administration > Config Management > Archive Management > Archive settings and setting is already e: /CIS~1/files/rme/dcma,
    Also from dbreade, by executing the sql "select * from Config_Device_Archive" in rmeng, I can see that some file location is C:drive and orther files location is E: drive, so I have run the below sql to correct it, although it executed correctly, by I can see that Config_Device_Archive table that still some devices location is c:, others is e: drive.
    update Config_Device_Archive set
    location=replace(location,'C:\\PROGRA~1\\CSCOpx','E:\\CAPCIS~1')
    Please advice, that how to resolve this issue.
    Thanks

  • Sync archive is successful, but cannot find latest config file in the config viewer

    Sync archive is successful, but cannot find latest config file in the config viewer, Prime LMS 4.2.4

    Hi,
    Go Admin > Collection Settings > Config > Config Archive Settings
    Make sure   enable shadow directory is Checked
    Also check you have folders like shadow , devfiles ..etc under NMSROOT/CSCOpx/files/rme/dcma
    If these folders are missing ... then it is a database issue..
    if files and folders are fine then check if it happening for any particulr device or set of devices or all the devices ?
    Thanks-
    Afroz
    ***Ratings Encourages Contributors ***

  • RME 4.3.1 not archiving configs on all devices

    As the part of the screen shot shown, I have a total of 1312 devices in the RME. The number of total devices RME tried to collect inventory adds up to that. However, the numbers it tried to archive configuration do not (581 + 116 + 23 + 58 = 778 = 1312 - 534).
    Why are so many devices missing there?
    An RME job deploying a configuration template failed on a large number of devices, which led me to discover that many devices don't have archived configuration.
    When I manually start a "Sync Archive" job from the Device Center on a device showing "Configuration Last Archived Time: No configuration archived yet", the job succeeds.
    This is a serious issue. My immediate concern is to get configuration archived on all devices. What do I need to do to get RME to do that?

    Thanks for the response.
    Yes, I have updated the device packages recently.
    Here is device package information for one of the devices that did not get config archived:
    1.
    1.3.6.1.4.1.9.1.516
    Cisco 3750 Stack
    CatGL3
    5.2
    When I try a device package update now on RME, I get "All the available package(s) at source location are already installed."
    When I try a device package update on all CiscoWorks modules, I only get one: DFMDeviceUpdates going from 17.0 to 18.0.

  • Cannot sync. Error message says "sync session failed to start"

    I am not able to sync my ipod. The error message "the ipod could not be synced because the sync session failed to start" keeps popping up. I have tried both syncing it plugged in and by wifi and the same message appears

    Same problem today. Took five times to reinstall without any error messages. Apple has posted a way to fix and you should follow their's first. I finally got to upldate correctly by doing their fix but with one difference. I did the following:
    1) Went to the C:\program files (x86)\iTunes and C:\program files\iTunes folders and moved every file ending in .dll to the desktop (even if two files in same location had the same name, just replace)
    2) Restarted computer and still got error message
    3) Uninstalled all apple programs possible in the following order......itunes, apples software update, apple mobile device support, bonjour, and apple application support.....all performed using the microsoft control panel
    4) put all the .dll files on the desktop in the trash and emptied (this is a step apple support did not specifically put in their fix but for a final try I wanted to delete everything apple).
    5) Restarted computer.
    6) Re-installed itunes from apple website
    No error messages during re-install and was able to open shortcut in one try. Even updated my ipad to make sure everything was working.

  • My iphone 5 won't sync, even i restored. it always appeared " The iPhone could not be synced because the sync session failed to start.

    my iPhone 5 won't sync even i restored. it always appeared  "The iPhone could not be synced because the sync session failed to start.

    https://discussions.apple.com/thread/3415227?start=0&tstart=0
    https://discussions.apple.com/message/16400530#16400530

  • Will not let me sync my playlist after new purchases - sync test failed

    error message from diagnostic:
    Microsoft Windows XP Professional Service Pack 2 (Build 2600)
    Hewlett-Packard HP Pavilion dv9000 (EZ458UA#ABA)
    iTunes 7.6.0.29
    QuickTime 7.4.1
    CD Driver 2.0.6.1
    CD Driver DLL 2.0.6.2
    Apple Mobile Device 1.1.3.26
    Bonjour 1.0.4.12 (118.4)
    iTunes Serial Number E72858419F57DA04
    Current user is an administrator.
    The current local date and time is 2008-06-19 10:50:29.
    iTunes is not running in safe mode.
    Video Display Information
    NVIDIA GeForce Go 6150
    ** External Plug-ins Information **
    No external plug-ins installed.
    ** Network Connectivity Tests **
    Network Adapter Information
    Adapter Name: {0D1D1EA1-C577-4A0B-B332-F0F06E997127}
    Description: Broadcom 802.11b/g WLAN - Packet Scheduler Miniport
    IP Address: 172.16.205.238
    Subnet Mask: 255.255.254.0
    Default Gateway: 172.16.204.254
    DHCP Enabled: Yes
    DHCP Server: 172.16.204.254
    Lease Obtained: Thu Jun 19 09:05:37 2008
    Lease Expires: Fri Jun 20 09:05:37 2008
    DNS Servers: 216.136.33.82
    216.136.33.82
    216.54.204.186
    Adapter Name: {C3658844-9940-4DCE-B624-6D3323FE3076}
    Description: NVIDIA nForce Networking Controller - Packet Scheduler Miniport
    IP Address: 0.0.0.0
    Subnet Mask: 0.0.0.0
    Default Gateway:
    DHCP Enabled: Yes
    DHCP Server: 192.168.1.1
    Lease Obtained: Sun Feb 11 10:25:51 2007
    Lease Expires: Mon Feb 12 10:25:51 2007
    DNS Servers:
    Active Connection: LAN Connection
    Connected: Yes
    Online: Yes
    Using Modem: No
    Using LAN: Yes
    Using Proxy: No
    Firewall Information
    Windows Firewall is on.
    iTunes is enabled in Windows Firewall.
    Connection attempt to Apple web site was successful.
    Connection attempt to iTunes Store was successful.
    Secure connection attempt to iTunes Store was successful.
    Secure connection attempt to iPhone activation server was successful.
    Last successful store access was 2008-06-19 10:48:57.
    ** CD/DVD Drive Tests **
    LowerFilters: PxHelp20 (2.0.0.0),
    UpperFilters: GEARAspiWDM (2.0.6.1),
    E: HL-DT-ST DVDRAM GSA-4084N, Rev KQ09
    Drive is empty.
    ** iPod/iPhone Connectivity Tests **
    iPodService 7.6.0.29 is currently running.
    iTunesHelper 7.6.0.29 is currently running.
    Apple Mobile Device service 1.14.0.0 is currently running.
    Universal Serial Bus Controllers:
    Standard OpenHCD USB Host Controller. Device is working properly.
    Standard Enhanced PCI to USB Host Controller. Device is working properly.
    FireWire (IEEE 1394) Host Controllers:
    OHCI Compliant IEEE 1394 Host Controller. Device is working properly.
    Most Recent Device Not Currently Connected:
    iPod nano (Second Generation) running firmware version 1.1.3
    Serial Number: YM652P5NVQK
    ** iPhone/iPod Touch Sync Tests **
    One or more sync tests failed.

    Two things:
    - Completely remove and reinstall the Apple software by the following.  That link provides a link for Win &.
    Removing and Reinstalling iTunes, QuickTime, and other software components for Windows XP
    - If you still have a problem after restoring the iPod to factory defaults/new iPod you likely have a hardware problem. An appointment at the Genius Bar of an Apple store is then in order.

  • HT1296 My iphone wont sync and all I get is a message saying that the sync session failed to start, any ideas on what I do next?

    Pretty much as above, when I plug my iphone in it just comes up with the message saying the sync session failed to start and thats all I can get out of it :/
    Any ideas on what I need to do to get my iphone to talk to my itunes again please?

    Hi hblower,
    As a first step, I would suggest quitting your open apps:
    iOS: Force an app to close
    http://support.apple.com/kb/ht5137
    Then sign out of iTunes:
    iOS: Changing the signed-in iTunes Store Apple ID account
    http://support.apple.com/kb/HT1311?viewlocale=en_US
    Restart and/or reset the device:
    iOS: Turning off and on (restarting) and resetting
    http://support.apple.com/kb/HT1430
    Are you running the latest version of iTunes?  If not, update the software and try syncing again …
    Cheers,
    Judy

  • When I sync my iPhone with iTunes I get an error message that says "iTunes could not sync calendars to the iPhone because the sync server failed to sync the iPhone"

    When I sync my iPhone with iTunes I get an error message that says "iTunes could not sync calendars to the iPhone because the sync server failed to sync the iPhone"  How do I fix this?

    I had the same problem.  I found this site http://itprokb.blogspot.com/2010/10/itunes-could-not-sync-calendars-to.html
    It worked for me.  Good luck!

Maybe you are looking for