Load error in FDM

Has anyone ever gotten a data load error message when performing the export step in FDM? Once I load my data, I get a two line error file that says data load started and data load completed, but is an error file. My file loads, but I cannot get a goldfish next to the check step.

Hi friends,
I have solution for my environment (11.1.1.3). Try this:
1) Open user preferences (workspace / file / preferences)
2) Select "Consolidation" and select target application
3) Go to the bottom of this dialog/form and UNCHECK "Save all files in Unicode format" option.
4) Try export again.
Vladislav

Similar Messages

  • Error while loading data from FDM (EPM 11.1.1.3)

    Hi,
    We are loading data into HFM from FDM. While loading data from FDM it is throwing an error which as below.
    "Load data started: 5/20/2012 9:30:45 PM
    Line 27, Error: Cell for Period Mar is not an input cell.
    Actual,2011,Mar,YTD,ENT_JJ,JPY,A23232323,ENT_J76;[None];[None];[None];ICP_Load;3463437"
    There were multiples lines which are throwing error.
    After doing some checking we found that when we unpost ICP data in HFM we were able to load data from FDM. We have not locked the ICP entities because that will restrcit to load data. But we are not able to understand just unposting the ICP values why we are able to load data from FDM. Also we have not closed the period in HFM.
    Kindly suggest, what could be the possible reason.
    Thanks
    Edited by: user12121146 on May 27, 2012 5:29 AM

    one way to figure this out, would be to open a grad at the same POV.
    It will rule out a couple things.
    If it is locked, you'll visually see that it is locked. (will be grey I believe)
    If it is an invalid intersection, you'll see that as well. (will be red)
    If you do not have access to the cell, you will see that if you look at cell status, it will say NO ACCESS.
    That should help you figure out what is happening, the quick and dirty way.

  • FDM Batch Loader Error

    Hello,
    I'm getting an error when trying to run a script from outside FDM workbench. The script works fine inside workbench and it's almost entirely copied out of the documentation.
    Script
    Sub autoload()
    Dim lngProcessLevel
    Dim strDelimiter
    Dim blnAutoMapCorrect
    Dim EssbaseFilePath
    Dim BATCHENG
    Set BATCHENG = CreateObject("upsWBatchLoaderDM.clsBatchLoader")
    BATCHENG.mInitialize API, SCRIPTENG
    lngProcessLevel = 10 'up to export
    strDelimiter= "_"
    blnAutoMapCorrect = False
    Set BATCHENG.PcolFiles = BATCHENG.fFileCollectionCreate(CStr(strDelimiter))
    'single processing
    BATCHENG.mFileCollectionProcess BATCHENG.PcolFiles, CLng(lngProcessLevel) ,, CBool(blnAutoMapCorrect)
    End Sub
    Batch
    C:\Hyperion\UpStream\WebLinkDataMart\SharedComponents\upsShell.exe CustomScriptEx=HFM2Ess2~<user>~<password>~<loadbalancer>~"e:\log"~autoload~LanguageCode=1033~EncodeUnicode=0
    Error
    ** Begin FDM Runtime Error Log Entry [7/26/2011 1:01:24 PM] **
    ERROR:
    Code............ 438
    Description..... Object doesn't support this property or method
    Procedure....... clsBlockProcessor.ActExport
    Component....... upsWBlockProcessorDM
    Version......... 920
    Thread.......... 38140
    IDENTIFICATION:
    User............<ADMIN>
    Computer Name... <SERVER>
    App Name........ <APP>
    Client App...... BatchEngine
    ** Begin FDM Runtime Error Log Entry [7/26/2011 1:01:24 PM] **
    ERROR:
    Code............ 438
    Description..... File [a_Essbase_FDMActual_Apr–2011_RA.dat] Caused - Object doesn't support this property or method
    Procedure....... clsBatchLoader.mFileCollectionProcess
    Component....... upsWBatchLoaderDM
    Version......... 920
    Thread.......... 33432
    My goal is to just create a simple automated process that will grab files from the openbatches directory but I'm kind of stuck as to why this would run fine in work bench but throw errors from outside using the syntax provided in the API / Admin guide...
    Edited by: user13048127 on Jul 26, 2011 12:58 PM

    You're right. It does appear to be failing at the export step even when stepping through the process manually from the web interface.
    It is generating a different error when doing that though:
    ** Begin Runtime Error Log Entry [7/27/2011 9:16:56 AM] **
    ERROR:
    Code............ 2500
    Description..... [EsbPutObject] Threw Code=
    Procedure....... clsHPDataManipulation.fCopyToServer
    Component....... upsEB7XG
    Version......... 100
    Thread.......... 35588
    ** Begin FDM Runtime Error Log Entry [7/27/2011 9:16:57 AM] **
    ERROR:
    Code............ 4100
    Description..... Stream Failed, Invalid file path provided!
    \\<server>\fdmdata\HFM2Ess2\HFM2Ess2\Data\33.ua2
    Procedure....... clsAppServer.fFileGetStream
    Component....... upsAppSv
    Version......... 920
    Thread.......... 38304
    In this situation the application is looking for a 33.ua2 file but there is only a 33.ua1 file in the directory... this was reproduceable (but with different numbers for the files e.g. 26.ua1 is present but it was looking for 26.ua2).
    I'm a little confused as to why the application would be looking for a file name different than the file generated.
    Could this be related to permissions or access?

  • Import error in FDM

    Hello Experts,
    When we are trying to import the .dat file into FDM, we are getting the following error. Error: An error occurred importing the file. Detail: Data access error
    User ID........... lgastaldello
    Location.......... DreamFDQM
    Source File....... \\ISSDRHYPDB\FDMDATA\ISS\Inbox\DreamFDQM\Jan GMTP USD.txt
    Processing Codes:
    BLANK............. Line is blank or empty.
    ESD............... Excluded String Detected, SKIP Field value was found.
    NN................ Non-Numeric, Amount field contains non numeric characters.
    RFM............... Required Field Missing.
    TC................ Type Conversion, Amount field could be converted to a number.
    ZP................ Zero Suppress, Amount field contains a 0 value and zero suppress is ON.
    Create Output File Start: [2011-05-04-07:40:32]
    [TC] - [Amount=NN] COMPANYCODE CURRENCY NOMINAL Stream CoStream NomCode Description Yearcode Period Type Value000s
    [ZP] - [Amount=0] GMTP USD BT410000 BT GMTPBT 410000 Exchange Differences - External 2011 01 CUMULATIVE 0.00 TB-LOAD
    [ZP] - [Amount=0] GMTP USD BT410000PH01 BT GMTPBT 410000 Exchange Differences - Unrealised 2011 01 CUMULATIVE 0.00 TB-LOAD
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [TC] - [Amount=NN]
    [Blank] -
    Excluded Record Count.............. 571
    Blank Record Count................. 1
    Total Records Bypassed............. 572
    Valid Records...................... 140
    Total Records Processed............ 712
    Begin SQL Server (BCP) Process (140): [2011-05-04-07:40:32]
    [RDMS Bulk Load Error Begin]
    Message: (-2147217900) - Data access error.
    See Bulk Load File: \\ISSDRHYPDB\FDMDATA\ISS\Inbox\tWlgasta426412848880.tmp
    [RDMS Bulk Load Error End]
    Could anyone Help me what is the exact problem and how to resolve this.
    Thank you,
    Anil

    To verify this, chang the insert type for the location from "Bulk Insert" to "SQL Insert" and then re-test the load. If it completes successfully, as Tony Mentioned, the issue is that the Service Account running the MSSQL Service, does not have read access to the FDM Application Folder Share.

  • I am getting Automation Error in FDM

    Hi,
    I am trying to load data from FDM into HFM, It was working fine till afternoon. I switched on Enable intersection validation ON and saved and did the Load;
    I got Automation Error. Then I disabled Enable intersection validation and tried loading data. I am getting same error Automation error.
    I saw in Metalink they said to configure your adapter. While doing reconfiguring I am getting some other error saying Specified Cast not valid.
    Can any one tell me what is going wrong? and how do I need to resolve this.
    Thanks,

    Is this a x64 server? Specified Cast is invalid indicates that the adpater was not registered properly. If it is a x64 server the adapter needs to be registered manually.
    Follow document 1073992.1 to resolve the issue.

  • HFM Data Load Error in ODI

    Hi,
    I'm loading data into HFM from flat file. When the interface is executed only some of the data are getting loaded. When i checked for the errors in the log, I'm getting the following error message in log:
    'Line: 56, Error: Invalid cell for Period Apr'
    Then i found that its an invalid intersection in HFM which am trying to load.
    In FDM there is an option to validate invalid intersections during data load.
    I would like to know how to do so in ODI to overcome this kind of error i.e. is there any option in ODI to ignore this kind of error.
    Kndly help me.
    Thanks in advance

    Hi,
    I think even if the metadata exists still there might be some issues with HFM forbidden cells. There are HFM rules that determines which intersections are editable/loadable which are not. Please look at your HFM admin regarding forbidden rules. Or otherwise change the property of Custom dimensions so that it accepts data into all intersections.
    Thanks,
    Debasis

  • Getting Page Load Error while opening a Opportunity in new window

    Hi All,
    outbound SSO is enabled.
    when i try to punch-in to my application from CRM through opportunity web link with Web Link Target as "open in custom tab" its working properly, but when i have Web Link Target as "open in new window" i am getting page load error. previously with out Outbounf SSO it is working properly.
    Do i need enable any settings in CRM
    thanks

    when the web link target is "open in new window" or "open in current window" the request send to third party application from CRM ONDemand is HTTPS request as SSL is not enabled it is giving "page load error"(In the web link we are specifying http only) (User athentication type is "username & password/ SSO")
    Is there any setting in CRM Ondemand to send Http request only instead of HTTPS?

  • Error building project using kXML2 - "Class loading error: Wrong name"

    Hi,
    I'm testing the XML-Parser KXML2 and downloaded the latest package, but the minimal version (kxml2-min.zip). I put this file into the directory "%j2mewtk%\apps\KxmlTest\lib" and wrote the lines
    import org.kxml2.io.*;
    import org.xmlpull.v1.*;
    When I try to build the project with the Wireless Toolkit (v1.04) it spits out the following error:
    Error preverifying class kxml2.io.KXmlParser
    Class loading error: Wrong name
    com.sun.kvem.ktools.ExecutionException: Preverifier returned 1
    Build failed
    I also tried the full package "kxml2.zip" but the same error occurs.
    How can I get rid of this? Thanks in advance!

    Okay, finally worked it out (hopefully). I unpacked the archive to a directory (say "%J2MEWTK%\apps\KxmlTest\tmpclasses") and then preverified them "manually":
    %J2SDK%\bin\preverify.exe -classpath "%J2MEWTK%\apps\KxmlTest\tmpclasses";"%J2MEWTK%\lib\midpapi.zip" org.kxml2.io.KXmlParser
    %J2SDK%\bin\preverify.exe -classpath "%J2MEWTK%\apps\KxmlTest\tmpclasses";"%J2MEWTK%\lib\midpapi.zip" org.xmlpull.v1.XmlPullParser
    %J2SDK%\bin\preverify.exe -classpath "%J2MEWTK%\apps\KxmlTest\tmpclasses";"%J2MEWTK%\lib\midpapi.zip" org.xmlpull.v1.XmlPullParserException
    Then I packed them again to a jar-file:
    %J2SDK%\bin\jar.exe -cvf kxml2-min.jar %J2MEWTK%\apps\KxmlTest\tmpclasses\output\.
    That was all!

  • Loading Errors-Essbase

    Hi all,
    Please help me with this..
    I got the following errors while load is running in essbase, I have seen this in log files..
    All other cubes loaded successfully, except 1 cube.
    ERROR 1054004 - Application is not loaded
    ERROR - 1002097 - Unable to load database
    The Oracle website shows
    Possible solution for 1st error is Make sure that you created the filters correctly.
    2nd error is not mentioned there.
    Please help me solving this issue.
    Cheers
    Prash

    Hi,
    First of all can you start this database from say EAS, does it say it cannot start?
    It might be a hung esssvr.exe process, stop all the databases and if you still see an esssvr.exe process running you may need to end that process unless you can stop it with maxl or esscmd.
    If you are unsure how to do it then it might be easier to give the box a reboot.
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Load error code 11 when attempting to open .vi from library

    Hello,
    Recently a colleague sent me a .llb containing a VI and sub-VIs of a program needed for my research.  The VI opens correctly but none of the sub-VIs can be found by it and when I attempt to open the sub-VIs I get load error code 11: VI version (6.0) cannot be converted to the current Labview verstion (8.5.1) because is has no block diagram. 
    I am running Vista with 8.5.1 and attempting to open a library of version 6.0.  I do not know what OS the library was compiled on.  (Linux is a possibility)  The colleague who sent me the program does not know either, as he recieved it from another colleague whom he is no longer in contact with.
    I am fairly certain the library was saved with block diagrams, so I do not think that is the source of the error.
    Does anyone know what might be a way to get these sub-VIs working?

    Okay,
    File posted.  Someone please tell me if this has a block diagram on it.
    Attachments:
    Find First Error.vi ‏24 KB

  • Solution to "Quicktime Plug-in failed to load" error

    My solution to "Plug-in failed to load" error message when attempting to watch demo movie on Apple website (and others):
    I found two Quick-time plugin.plugin files in my Internet Plug-ins folder in my
    User Library folder. One was version 6.3 and one was version 6.5.2.
    Removing the 6.3 version solved the problem. Removing the 6.5.2 version had no effect, so I removed it also.
    Never could have solved this one without the help of Woody at Apple!!!!

    Why not install version 7?

  • Stor.e TV+ No Loader error keeps coming up when switching on

    I have been experiencing continual problems accessing the hard drive. "No Loader" error message keeps coming up when switching on.
    The so-called "solution" to this problem posted on this forum is to open up the box and fiddle with the cables. Whilst I have had some success with this method initially, dismantling the box 10 times a week is not on.
    I tried something else in desperation.
    When the No Loader message comes up, I switch the box off and on again from the remote.
    After 2 or 3 times or so the HDD folder usually appears.
    I have been doing this consistently now with great success. This however suggests that the No Loader error message is NOT a mechanical connector problem with the hard drive but (as usual) poor software (what else?).
    Dismantling the unit is tantamount to switching it off for an extended period of time so may explain why this technique works.
    Switching the unit on and off several times also solves the problem of the D folder not appearing on the network even though Win7 shows Store-TV-Plus as a mapped NTFS drive (but can't find the D folder).
    See the similarity?
    Another thing that exacerbates problems is the unit's poor ventilation. The first thing that happens with this unit is that the rubbish stick-on rubber feet fall off.
    Whilst this may seem innocuous, the ventilation slots are underneath the unit and will be blocked if there are no feet. I live in a hot country so this device gets pretty hot and behaves even more erratically unless well ventilated.
    Ideally keep it well away from other units and preferably sit it on a small box by itself with the vents underneath well exposed.
    I also still experience problems playing FLAC and MKV files. The unit occasionally loses synch with FLAC files which generally otherwise play OK and locks up or causes loud bangs or white noise on the speakers (dangerous).
    Some MKV files just don't play at all even though VLC plays them. There are a myriad other inconsistencies but these are the most annoying.
    Is anyone else experiencing these problems or does anyone have any other solutions to prevent these problems?
    I don't suppose we can expect another software upgrade from Toshiba? In your dreams, pal.

    OK, so I took the risk and updated the firmware of my Stor.e TV+ to the Noontec V8S latest firmware V3.0816.13_V8S from noontec website.
    The update went fine without a hitch (took about 2 minutes from an old 256MB flash drive plugged into the back USB port of the unit, which I formatted before using), and some of the irritating shortcomings of the Toshiba firmware was solved. Samba worked in some fashion, but I was still not able to download songs directly to the Stor.e over wireless, which is the only other feature I currently need. The irritating remote control buttons were changed to the way any sane person would use them (I had changed my universal remote control to correct this, so would have to change the settings if I kept the updated firmware) The new firmware seems solid, but I DON'T USE THE VIDEO CAPABLITIES, so I can't comment on this.
    One major drawback of this update for me is that the small display on the unit becomes much less readable. Seems like there is a problem with the font on the new firmware. I use my Stor.e exclusively as a flac music player, and since I don't have it connected to a tv the small display is crucial for me to select tracks or disks. I have 300+ discs, so the Stor.e is an excellent cheap media player which I connect to my HIFI system via a DAC.
    I thus had to change back to the Toshiba firmware to correct this problem. Seems like I would still have to use USB to download music to the Stor.e when I buy new CDs. What a pity.
    Incidentally, the new Toshiba firmware is very much like the old firmware, in that it lacks the capability to switch on Samba. In the readme Toshiba states that the new firmware fixes a network problem, but I think that this is probably the smallest issue most users have with the Toshiba firmware.
    So, my advice to anyone having video, control or other issues with the Toshiba firmware is to flash to the Noontec firmware to see if it resolves their issues. If it doesn't one can always revert to the official Toshiba firmware as I did.
    You do this at your own risk though, if you brick your unit don't blame me...

  • I have an iPod nano v4 or 5 and when I connect it to my Hyundai Santa Fe I get an iPod loading error message.  The cable came with the car when I purchased it and the dealer was able to get it to work with his newer ipod.  Please advise.

    I have an iPod Nano v4 or 5 and when I connect it to my Hyundai Santa Fe I get an iPod Loading error message.  The cable works with the dealer's iPod which is a newer model.  The cable came with the car when I purchased it.  Please advise.  Thanks.

    Hi Bander Bunny!
    I have a couple of articles that should be able to help you troubleshoot this issue a little further. You may want to try uninstalling and reinstalling iTunes first. This has to be done in a specific manner, and this article can help you do that:
    Removing and reinstalling iTunes, QuickTime, and other software components for Windows Vista or Windows 7
    http://support.apple.com/kb/ht1923
    Another option is that you may want to try syncing your iPod nano manually. Here's is an article that pertains to manually managing the content of your iPod nano:
    Managing content manually on iPhone, iPad, and iPod
    http://support.apple.com/kb/ht1535
    It's also possible that this issue resides with your iPod nano. Here is a website that will help you troubleshoot the iPod nano:
    Apple - Support - iPod Troubleshooting Assistants
    http://www.apple.com/support/ipod/five_rs/
    Thanks for using the Apple Support Communities. Have a good one!
    -Braden

  • Program Load Error

    HI everyone,
        I have a problem regarding abap program,
    I have transported a program with tcode from development server to production  server but when i run the program in production server the program gives a runtime error.
    " Program Load Error " thus dumping the program.
    when i checked it in SE38 of production server it quotes " program does not exiist ".
    Can please anyone let me know wat is the reason??
    Thank you,
    Vivek.

    Hi vivekacharya,
    I think you saved  the report and tcode in different Transports Requests, you moved only one request in which the report is not exsist.
    so  go to se38 program goto utilities --> versions  -->  version management and then  get the request and transport  the request to production server.
    Regards,
    Sateesh

  • What can I do about "LabVIEW load error code 38: Failed to uncompress part of the VI."

    While attempting to load an executable LabVIEW application for LabVIEW 2009 SP1 on a Windows-XP machine when the following pop-up message occurs. "LabVIEW: Memory or data structure corrupt. An error occurs in loading VI 'NI_Gmath.lblib: Backward Bracket Search.VI'. LabVIEW load error code 38: Failed to uncompress part of the VI. The VI is most likely corrupt." What seems odd is that the same LabVIEW application loads fine when logged on as a privileged user account, but fails to load on a private user account.
    Attachments:
    2012-07-18 LabVIEW Load error code 38.jpg ‏1314 KB

    Here's a thought:
    So when something is decompressed, a temp folder is often used. 
    I have no idea why LabVIEW would be decompressing anything, but I suspect it is trying to put the decompressed file into a temp folder where the user does not have write permissions.
    In the .ini file for your executable, you can add a line that specified the location of the temp folder to use:
    tmpdir=C:\Temp
    On my Win7 machine, the location is:
    C:\Users\MyUserName\AppData\Local\Temp
    On WinXP, it is probably:
    C:\Documents And Settings\YourUserName\local settings\temp
     Try changing the tmpdir key in your ini file to something to C:\Temp and see if that helps.
    - john

Maybe you are looking for

  • Changes in IMG setting

    Hi How we can display changes made to date if we don't know TR number in IMG ( Release class-charactertics ) ?

  • 10.4.10 completely shuts down in the middle of an app

    Hi Since downloading the new update 10.4.10 for my Macbook Pro Core Duo i have several uncharateristic complete shut downs in differnet applications. One in Preview, one while typing and email in Mail and one in Safari. I have had no Printing issues,

  • Kde 4.8.2 adds konqueror and dolphin automatically

    hi,      I am using KDE 4.8.2 and I see Konqueror & Dolphin in my taskbar so I remove them by right clicking them and selecting "Remove This Launcher" from the popup menu. However, everytime I restart my machine, they come back and is very irritating

  • Presenting Query results as HTML

    Hello, We currently have an application server logging into oracle. Currently the application pulls 2000 rows and then converts them into html formatted text. Is there a better way to this than having to first pull the 2000 rows into weblogic and the

  • Communication between webservers

    i want to send a servlet request along with some information from a servlet running on one webserver to another servlet running on a different webserver how to make it possible?