Loading from ODS to Cube in process chain

Hi Experts,
How can I do a full load from ODS to cube when using further processing in process chain? Your help is much appreciated.
Thanks,
Bill

Hi,
You can use a DTP for this.
Create transformation between DSO and cube.
Create DTP and run it.
Loading data from one cube to another cube.
Cube to cube data loading
how to upload data from cube to cube
Can we pull data from one cube to another cube
Data Load Steps:
Reading data from another cube
Hope this helps.
Thanks,
JituK

Similar Messages

  • Can I do Parallel Full loads from ODS to Cube.

    Hai,
       Usually I will do one a full update load from OD'S to Cube. to speed up the process can I do parallel Full update loads from ods to Cube?
    Please advise.
    Thanks, Vijay,

    Assuming that the only connection we are talking about is between a single ODS and a single Cube.
    I think the only time you could speed anything up is in full drop an reload scenario. You could create multiple InfoPackages based on selection and execute them simultaneously.
    If the update is a delta there is really no way to do it.
    How many records are we talking about? Is there logic in the update rule?

  • Error when loading from ODS to Cube

    Hello Friends,
    I am having trouble loading data from ODS to Infocube in my 2004S system.When loading data i get this message
    07/03/2007     13:10:25     Data target 'ODSXYZ ' removed from list of loadable targets; not loadable.
    07/03/2007     13:28:42     Data target 'ODSXYZ ' is not active or is incorrect; no loading allowed     
    I checked for ODSXYZ in my data target but there is nothing by that name.Even the infopackage doesnt have it.What needs to be done.Please help.
    Thanks.

    Its a expected behavior. When you migrate ur DS, the infopacks associated with it, will grey out all the data targets that they were feeding before, that applies to any infopack you create even after the migration. You womt be able to delete it.
    Having said this, this shouldnt impact ur loads from ODS to Cube. As this shoudl be taken care of by ur DTP's rather than ur infopacks.
    A few questions:
    How are you loading ur cube?
    Did the data get thru fine to PSA with the infopack in question?
    How did you load ur DSO(assuming the load was successful)?
    Message was edited by:
            voodi

  • Index for loads from ODS To Cube

    The load from ODS to cube is taking a long time - In the start routine another ODS is being looked up - The keys for look up is say X and Y
    There is already an index existing on keys X , Y & Z -
    Will this index be used while doing the select on that ODS or I need to create a new index with only X and Y keys ?
    Thnx

    When you are running the start routine - run an SQL trace - ST05 - that will tell you if the index is being used.
    Arun

  • Automatic loading from ODS to Cube in 3.5

    Hi All
    I was under the impression that in version 3.5 in order to load delta from ODS to Cube you had to run the 8 series Ipak.
    However I have recently noticed that this ipak is running automatically after a delta load into the ODS even when the load is not via a process chain.
    Can somebody where and how this setting is maintained.
    Regards
    A

    Hi,
    Go to ODS display mode and check if "Update Data Automatically" is ticked in Settings.
    Regards,
    Kams

  • Loading from ODS to Cube

    I have a process chain for GL.
    Data was getting loaded first to ODS and then to CUBE.
    Now i there is no update to cube is scheduled. I removed  'Further Update'  process from process chain.
    During loading  I am getting a warning message as follow:
    There must be a type "Update ODS Object Data (Further Update)" process behind process "Activate ODS Object Data" var.ACTIVATE_ODSu201D
    So plz suggest me any way to remove this warning message.
    Thanx,
    Vishal

    Hi Vishal,
    since you removed 'Further Update' process from process chain, this message is comming, i hope instead of this peorcess you are loading dta from ODS to Cube using Infopackge at process chain.
    at ODS - setting uncheck setting Further update to data targets (i assume you are loading data from ODS to Cube using Infopackage at process chain).
    Best Regards.

  • Error while loading from ODS to CUBE

    Hi guys,
    I am loading data from source system to ODS and from ODS to CUBE. Ok. The data came successfully from Source System to ODS. But while coming to ODS to CUBE it is showing some error at Data Packet 13. Ok. In CUBE, I loaded the data by using “update ODS data to data target”, at that time it shows two options like FULL UPDATE and INIT UPDATE. Then I selected FULL UPDATE and then I checked in “processing” tab there is only one option enabled i.e. only data target. OK and then I loaded it. Now after getting the error where I can correct it. There is no PSA option in monitoring.
             Other wise how I can change option in Processing tab of infopackage for PSA. But I know one point that when we load the data from one target to another the only one option available in processing tab is “only data target”. How can I change that option and how can I correct the error.
    Thanks
    Rajesh

    Hi,
    i solved my question like the following.
    Go to monitoring of the CUBE and select the option "read every thing as manually" -> then it shows another screen for correcting the records -> correct all the records and load the data again. ok
    Thanks
    Rajesh

  • Data loading from ODS to CUBE

    Hi All,
    I have loaded data from ODS to CUBE. now i have requirement to add some fields in the standard cube. so, for testing purpose i have created copy of the original and created transformation . now when i try to load data from ODS it shows me no more data available . while data is already there in ODS.
    now what should i do ? i don't want to delete data from original cube. is there any other way to load data through transformation ?
    Regards,
    Komik Shah

    Hi,
    Check the DTP of old cube n see whether its Delta. If yes then check whether any one of the foll is check:
    1) get delta only once
    2) get data by request.
    If 1 is checked then delta wont come for the second cube as it says to get delta once and delta is already in one of the cube.
    Generally both should be unchecked but can vary as per requirements.
    Now for your new DTP, i dont think it will aloow you to change to FULL.
    If its allowing you to select FULL, then select it and select from acive table.
    try to load and see.
    regds,
    Shashank

  • How to remove a requisition load from an infocube in a process chain?

    Hello everyone!!
    We have an internal BI in SAP APO and I have created a infocube to backup all data in the DP module.
    I have also created a process chain to schedule the load daily.
    Please, consider this:
    - I have to load every day a full load, I can´t schedule a delta load, because the data in the past can be changed and need to be load in the cube.
    - In the infopackage I´ll have to set a time period range, so the data would be loaded in the cube.
    My doubt is:
    - How can I set a rolling end date in the infopackage and how can I eliminate the requisition loaded using the process chain?
    Thanks a lot
    Regards
    Angela

    Hi,
    Please, consider this:
    I have to load every day a full load, I can´t schedule a delta load, because the data in the past can be changed and need to be load in the cube.
    In the infopackage I´ll have to set a time period range, so the data would be loaded in the cube.
    You can load day wise by using simple ABAP routine in InfoPackage, and also you can keep this InfoPackage in Process Chains.
    If you have 0CALDAY InfoObject in InfoPackage Data Selection tab, you write the following routines for that object
    *$*$ begin of routine - insert your code only below this line        *-*
    data: l_idx like sy-tabix,
          dat1 like sy-datum.
          dat1 = sy-datum.
              read table l_t_range with key
                   fieldname = 'RDATE'.
              l_idx = sy-tabix.
    IF SY-SUBRC  = 0.
        l_t_range-option = 'EQ'.
        l_t_range-sign  = 'I'.
        l_t_range-low   = dat1.
        modify l_t_range index l_idx.
    ENDIF.
        p_subrc = 0.
    *$*$ end of routine - insert your code only before this line         *-*
    Note: You can also do sy-datum -1 and sy-datum + 1 type of calculations.
    In my case  'RDATE' is teh field coming from ECC and mapped to 0CALDAY.
    My doubt is:
    How can I set a rolling end date in the infopackage and how can I eliminate the requisition loaded using the process chain?
    You can also check the following Article, I have teh similar requirement for SNP runs, so I resolved teh issue by using selective deletion.
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/603a9558-0af1-2b10-86a3-c685c60071bc
    Thanks
    Reddy

  • ARFCSTATE = SYSFAIL ??????? loading from ODS to cube

    Hi,
    I am loading a delta initialization from ODS to a cube. The load goes fine but never ends. I saw through SM37 transaction and the job has finished but with these messages at the end:
    tRFC: Data Package = 6, TID = 0A11010C066C45438FC70221, Duration = 01:01:03, <b>ARFCSTATE = SYSFAIL</b>
    tRFC: Start = 28.10.2006 12:10:34, End = 28.10.2006 13:11:37                                    
    tRFC: Data Package = 7, TID = 0A11010C066C45438FE00222, Duration = 01:01:38, <b>ARFCSTATE = SYSFAIL</b>
    tRFC: Start = 28.10.2006 12:10:59, End = 28.10.2006 13:12:37                                    
    tRFC: Data Package = 8, TID = 0A11010C066C45438FE90223, Duration = 01:01:32, <b>ARFCSTATE = SYSFAIL</b>
    tRFC: Start = 28.10.2006 12:11:07, End = 28.10.2006 13:12:39                                    
    tRFC: Data Package = 10, TID = 0A11010C04BC454390020000, Duration = 01:01:12, <b>ARFCSTATE = SYSFAIL</b>
    tRFC: Start = 28.10.2006 12:11:32, End = 28.10.2006 13:12:44                                    
    Synchronized transmission of info IDoc 5 (0 parallel tasks)                                     
    tRFC: Data Package = 0, TID = , Duration = 00:00:03, ARFCSTATE =                                
    tRFC: Start = 28.10.2006 13:12:45, End = 28.10.2006 13:12:48                                    
    Job finished                                                                               
    What does this ARFCSTATE = SYSFAIL means and how to correct this?
    Thanks for your help!!!

    Hi Miguel Sanchez,
    I hope you have with PSA in IP.  If not run with PSA option and goto Detail tab of the Monitor , Expand the node Extraction Check for the message 'Data Selection is Ended'.
    If you find this message you can update from PSA.
    otherwise Go for Repeat the Delta.
    and also refer the notes 516251.
    also the error you are reporting could be for several reasons.  Could you therefore please check the following:
    1) check the RFC destination in SM59 for both your BW my self system
    2) in SM59, in BW source system, go to menu path "test"
       -> "connection" and test this for errors
    3) in SM59, in your BW  source system, go to menu path "test"
       -> "authorization" and check if the user and password are o.k.
    4) check the port definitions in WE20 and WE21
    5) finally check that you have sufficient DIA processes defined in
       your BW and R/3 source system (you should have at least one more
       DIA process than all other work processes combined; this is described
       in more detail in notes 561880 and 74141).
    Please check if this solves the problem for you.
    Hope it helps.
    Regards,
    Srikanth.

  • Data loads from ODS TO CUBE

    Hi,
       i have delta loads comming into the ODS. i do full update from ODS to the cube by date range for material moments no. last time when i loaded the data, it loaded few for the date range. rest did not load and sitting at ODS. this is full load and tried to load again. any suggestions...
    sp

    Hi Srinivas,
            check your update rules between ODS and cube whether they are mapped properly(check your date range for the cube load).
             Do a Init load and then do the delta load.
    hope this will help.

  • Delta load from ODS to cube failed - Data mismatch

    Hi all
    We have a scenario where the data flow is like
    R/3 table - >dataSrc -- > pSA - >InfoSrc -> ODS ->Cube.
    The cube has an additional field called "monthly version"
    and since it is a history cube , it is supposed to hold data
    snapshots of the all data in current cube for each month .
    We are facing the problem that the Data for the current month
    is there in the history ODS but not in the cube . In the ODS ->Manage->requests
    tab i can see only 1 red request that too with 0 recs.
    However ,In the cube -> manage-> reconstruction tab , i can see 2 Red request
    with the current month date. Could these red requests be the reason for
    data mismatch in ODS and cube .
    Please guide as to how can i solve this problem .
    thanks all
    annie

    Hi
    Thanks for the reply.
    Load to Cube is Delta and goes daily .
    Load to ODS is a full on daily basis .
    Can you help me how to sort this issue . I have to work directly in production env . so has to be safe and full proof .
    Thanks
    annie

  • No data loaded from ODS to Cube

    Hi,
    I am trying to do init with data transfer from 0FIAP_O03 to 0FIAP_C03...
    though there is data in the ODS, nothing is loaded to the cube. It just says
    No data available
    Diagnosis
    The data request was a full update.
    In this case, the corresponding table in the source system does not
    contain any data.
    System Response
    Info IDoc received with status 8.
    Procedure
    Check the data basis in the source system.
    Any suggestions?
    Thanks
    Shalini

    Hi
    "Info IDoc received with status 8" implies that there is no data in the source.
    But as you say, that data is there in  the source(ODS), then there is some inconsistency in the data source and you need to replicate the data source and reactivate that.
    IDoc Status 8 signifies that there is no data in the source and its not any error.
    For more info on idocs check the below link
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/0087780d-81b0-2a10-eb82-86e1062f1a2d
    Also goto sm58 and clear the idoc there.
    Hope this helps
    Regards
    Shilpa

  • We have some data loads from ODS to Cube (Deltas)

    Dear Experts,
    We can see request status green in DSO but in cube it is in yellow and not available for reporting (the request got compressed)
    I want to make the status to green and available for reporting but i could'nt do it as i can see some popup message saying the request is already activated and change QM status not possible.
    when i run the delta again that also becomes yellow status due to the previous request's was in yello status.
    please suggest me how to change the status of compressed request and why it is happening.
    Thank you in advance,
    Kiran.

    Hi,
    Chk whether automatic request processing--->Set quality status Ok checked or not?
    It might be in manage of cube, in the menu-->goto options somewhere
    as I was not before the system ...I couln't guide u exactly...
    rgds,
    Edited by: Krishna Rao on Mar 30, 2010 3:47 PM

  • Delta Load failure from ODS to Cube

    Experts,
    After CRM upgrade, I had to reinitilized the delta process. In this, I reloaded ODS with first init delta without data and then delta load with new data created in CRM. This worked good so far. After this when I tried to load cube with init. delta without data, no issues. But delta load from ODS to Cube doesn't work. Does anybody have any suggestions, please?
    Thanks,
    Nimesh
    Following error observed in Status for delta load from ODS to Cube.
    Error when transferring data; communication error when analyzing
    Diagnosis
    Data Packets or Info Packets are missing in BW, but there were - as far as can be seen - no processing errors in the source system. It is
    therefore probable that an error arose in the data transfer.
    With the analysis an attempt was made to read the ALE outbox of the source system, which lead to error .
    It is possible that no connection exists to the source system.
    Procedure
    Check the TRFC overview in the source system.
    Check the connection of the source system for errors and check the
    authorizations and profiles of the remote user in both the BW and
    source systems.
    Check th ALE outbox of the source system for IDocs that have not been

    Hi,
    As far as i understood, you have successful deltas' loading to the ODS and you want to update entire ODS data to the Cube followed by daily delta's.
    If this is the case,
    Make sure that you have active update rules exist between ODS and Cube.
    First goto your ODS and right click and select option 'Update ODS data in data target'.
    Select Init update > IT will take you to the init info package where you select init <b>with data transfer</b> (Init with data transfer will bring all the records from ODS to Cube)
    Once init is completed ,you can schedule to load delta's regularly form ODS to Cube by following the same steps.
    Hope this helps
    Praveen
    Message was edited by:
            Praveen Vujjini

Maybe you are looking for

  • Websites published from photostream can't load images

    So, I've created quite a few photostreams and always check the box to create websites viewable on any device (ie without iCloud).  Now, when I try to view these websites using Chrome browser, they appear with the correct image count, but none of the

  • Change Icon displaying as X?

    Our customer's display screen has a change button, button is functional, but it is an X instead of the correct GIF. It has the properties of: http://philfmc-svXXX:XX/sap/its/mimes/Webrfc/sapicons/s_b_chgb.gif. I realize, I think, that I should be abl

  • SAP DMS server installation

    Hi all, I am very new to DMS,seriously have no idea.I have to install SAP DMS server but have no idea from where to get the software.Can anyone help me please. Also if any one can provide me the configuration document i will be highly thankful Regard

  • Turning of auto adjust in develop mode.

    Hi everyone. My develop mode adjusts my pictures automaticlly. Can I turn this off somehow? Thanks James

  • CATW integration with portal (IAC session)

    I'm trying to integrate the catw application in the portal with a IAC iview. The application itself work's fine.  But when I close the application (closing the window without pressing the ext button)  the user is locked out for a while. We don't want