Lock Sing on an infotype screen

Hi all,
can someone explain what a lock sign in pa20 in a certain infotype means - in this case it is in infotype 6.
The sign appears right next to the change user name in the header of the screen.
Thanks,

Hi Sascha,
i had similar doubt few days ago. went thru the link
suresh suggested which gave me better understanding.
follow the thread.
What is the significance of LOCK INDICATOR in IT0006?
hope it helps.

Similar Messages

  • My grandsons new Apple refurbed 35g ipad keeps locking up with a black screen amd nothing else. I have reset it many times pressing the home and off buttons together but uit keeps locking up. Help,please!

    My grandsons new Apple refurbed 35g ipad keeps locking up with a black screen amd nothing else. I have reset it many times pressing the home and off buttons together but it keeps locking up. Help,please!

    Thank you for trying to help. I followed your instructions, it took 6 hours to download, and then said it could not solve the problem (something to do with error 9?). It will have to go back to Apple - its only 3 days since it came out of the package and its very disappointing for him. Looks like I have to hang around in the Apple store in Plymouth all tomorrow until they can fix it, or will change it. Thanks for your help.

  • HT4061 My iPhone 4S is locked on the iTunes connect screen and none of the reset instructions worked.

    My iPhone 4S is locked on the iTunes connect screen and the 'turn off' and 'reste' instructions were followed but it's still locked.

    iOS: Unable to update or restore

  • Feature to default values on infotype screens

    Hi All,
    Could I use a Feature (txn PE03) to determine the default values on an infotype screen?
    For example, I want the value in field FUNKT on Infotype 34 to default to say 'KLMN' if the Employee Group is '1' and the Emp. sub group is 'Z5'.
    I would like to use the screen modification config (table T588M) to assign the Feature and get the values without coding.
    I know I can achieve this by using a subroutine on dynamic actions or a BADI for infotype processing etc. but I am lazy and don't want to code if I can avoid it.
    Many thanks in advance
    Sanjay

    Thanks Sarika.
    I can create a Feature in PE03 but how do I use that in the config (table T588M)? Because if I am not able to use it in the config, I will be forced to code (using any Fn. Mods of the likes of HRFEATUREBACK*).
    The Feature ABKRS doesn't seem to be specified in table T588M as such there is bound to be coding behind it in the IT0001 processing programs.
    Cheers,
    Sanjay

  • HR Infotype Screen Programming!

    Hi All,
    I have a text field in my infotype screen which is editable.
    By default, the enteries are in CAPS.
    What do i need to do, if i want the field to accept "Caps" and small letters aswell?
    Thanks in advance for all the responses.
    Regards,
    Sundar.

    Sundar,
    If you are working with a standard SAP infotype, fields and Screens, this change is considered a modification.
    The other thing that you should check is if your field is tied to something defined in the data dictionary, then upper/lowercase is also attached to the domain of your field definition.  Changing it only on the screen may not necessarily populate the field with upper/lowercase.
    If you click on the "definition" tab of the domain definition you will see a checkbox called upper/lower case.
    Best Regards,
    Chris H.

  • How to hide OM infotype screen field

    Hello Experts.
    Please let me know how to hide OM infotype Screen field ? i want to hide Percentage field on IT1011.
    I know i can create alternative screen "Z" and hide the field and attach alternative screen to the Module pool.
    Please let me know if i can do this using BADI so there will not be any change to standard.
    Regards,
    Saurabh

    Hi Shiva,
    To get the detail about a table filed you can use DDIF* function module.
    Here in this particular case you can use FM   DDIF_FIELDINFO_GET.
    Pass the table name & field name.
    After executing that FM you can check   DFIES_TAB  in Tables parameter. i t will be having an entry.
    Check for filed name as   KEYFLAG  , if it is not initial ie.  X then supplied filed is Primary Key.
    If KEYFLAG is initial then supplied filed is not a primary key.
    Thanks & Regards
    Satyam

  • Way to see infotype screen without going PA20?

    Hi Experts,
    Is there a way to see just the infotype screen without going to PA20. I want to see the changes I am making using T588M and see which field has what technical field name and how the screen will look like when I make changes using T588m?
    Thanks a bunch,
    JESS..

    Hi,
    You can also check screen painter through transaction SE51. Give the module pool name under u201Cprogramu201D and the screen number, select layout editor and display. If you click on any field, the technical name will appear in the u201Cnameu201D row above. Further, any field with u201C?u201D is a mandatory field.
    Hope this helps.
    Donnie

  • Copy Standard infotype screen for country purpose

    Hi,
    I am trying to copy the Standard screen (2007) for the infotype IT0002 to make some country specific modification.
    However I am not able to copy the standard screen as it is asking for the Access Key.
    Can you please suggest if there is a way to copy the standard infotype screen without providing the access key.
    Regards
    Bharath

    Hi,
    Why don't you just enhance the infotype via PM01 - Enhance single screen?
    (MP000200 screen 2007)
    Regards,
    Dilek
    Edited by: Dilek Ersoz Adak on Feb 8, 2010 6:53 PM

  • Infotype screen chage

    Hi All,
    How do i change infotype screen for infotype2?.If i hit system menu  status  it shows screen number 2000.I need 2010 for molga 14 ugr92.Points will be rewarded.
    Thanks.
    Message was edited by:
            fred johnson
    Message was edited by:
            fred johnson

    Hi!
    I am not sure, if you have tries Customising User Interfaces in the IMG under personnel admin.
    Rgds
    Sarajit

  • HT4623 My iphone had an error while updating and is now locked up on the apple screen with the progress bar

    Itunes was updating my phone from 6.01 to 6.1 and it came up with an error. I closed the error not thinking about it and now my phone is locked up on the apple screen with the progress bar on it.

    hi i tried to update my iphone 3gs from ios 4.1 to 6.1.2, while doing the same i got an error message (-5000) which i ignored an continued. it was almost about to complete while my itunes is not able to detect the iphone kindly help.

  • How to use lock pattern for ur home screen in pod touch 4g(ios 5)

    how to use lock pattern for ur home screen in pod touch 4g(ios 5)

    Video formats:
    H.264 video up to 720p, 30 frames per second, Main Profile level 3.1 with AAC-LC audio up to 160 Kbps, 48kHz, stereo audio in .m4v, .mp4, and .mov file formats
    MPEG-4 video up to 2.5 Mbps, 640 by 480 pixels, 30 frames per second, Simple Profile with AAC-LC audio up to 160 Kbps per channel, 48kHz, stereo audio in .m4v, .mp4, and .mov file formats
    Motion JPEG (M-JPEG) up to 35 Mbps, 1280 by 720 pixels, 30 frames per second, audio in ulaw, PCM stereo audio in .avi file format
    Support for 1024 by 768 pixels with Apple VGA Adapter; 576p and 480p with Apple Component AV Cable; 576i and 480i with Apple Composite AV Cable (cables sold separately)

  • Add ifnotype field to an Infotype Screen Control for Infotype 0006

    How do I add an infotype field to an Infotype Screen Control for Infotype 0006. We need to add an additional Field for mobile phones. I have lloked in screen control (V_T588M) with no joy.
    Edited by: Henry Manana on Sep 1, 2010 12:11 PM
    Edited by: Henry Manana on Sep 1, 2010 12:12 PM

    You may copy your current screen into a new screen (e.g. 2099) for MP000600 and add the 2 fields into the element list as well as the screen layout of screen 2099. Then set an appropriate Modification Group 3 to these 2 fields in T588M detail screen for screen 2099. Configure feature P0006 and table T588M to set screen 2099 for molga 16.

  • Infotype Screen Control (T588M) not working for additional fields to contro

    Hi,
    I have a requirement to enhance IT 0002 with fields LNAMR, FNAMR and CNAME. Also field preferred language.
    I have included LNAMR, FNAMR & CNAME as additional fields in the Include Screen 2040 elements, lay editor and maintained table T582c where i have assigned enhancement to the standard screen. These fields are getting displayed in infotype 0002
    But the issue is Infotype Screen Control (T588M) is not working for these fields to control the display or hide.
    Has any of you come across this issue? what could be the reason for this issue? Please suggest ASAP.
    Thanks in advance.
    Regards

    Hi Experts,
    Please help with your inputs and suggestions.
    Regards

  • When i boot my cd to install mac ox a lock logo appers in the screen. help what will i do?

    when i boot my cd to install mac ox a lock logo appers in the screen. help what will i do? macbook pro thanks for the help..

    Provide the computer's firmware password and press Enter. If you don't know the password and can't turn firmware password protection off, contact Apple.
    (79746)

  • HT4623 locked in connect to itunes screen during update

    I am locked in connect to itunes screen since ios 6.0 update. I can not get it to turn on at all
    Please help!!
    Thank you!

    so do as the diagram states:  connect your phone to your computer and restore via iTunes.

Maybe you are looking for