Log HR infotype changes without a Mod like Change Documents
We need some help with a requirement. We need to monitor HR infotype changes. We would like to be able to trigger a event like a change pointer and IDOC. However, we are trying to stay away from mods to our system. We are needed fields from 0000,0001,0003,0006,0105. Most of the fields do not have Change Documents set and would required us to create a mod to flag the data elements. We also tried to trigger and monitor these changes in ZXPADU02 until we realized that once we get to 0003,0006,0105 in zxpadu02 we don't know what the person is inserting in that specific infotype, because the exit function module does not bring in information on changes to those infotypes. We would really like to be able to trigger off of a event without creating a mod. We would like to not have to run a program to read the logging files because we like the responsiveness and real time actions of triggering and not running a periodic program. We are trying to push these changes out of SAP.
Thanks
Have a look at HRMD_A05 this idoc type can transport the infotypes you mentioned and of course you can activate change pointers for that in bd50 (message type hrmd_a)
Similar Messages
-
How to get slide change without a noise like a camera shot?
I have imported a PP2013 slideshow into CP 8.
The animation is working correct.
But when the slide changes to the next one,
there is a noise lik a camera shot.
Where can I eliminate that,
ThanksHi Manoj,
Correct, when you query the CMS database it will return the info for the object and not the source.
In code you can use this for Crystal Reports:
reportClientDocument.SummaryInfo.( multiple values )
This is the info saved with the RPT file, you can also use Windows File API's to get the same info.
For WEBI and DESKI doc's it does not keep that info in the file system. You may want to look at the file system properties in the FRS to see if any info is kept as it is in RPT files but we ahve no API to get the info.
Thank you
Don -
My homepage keeps changing without my permission, it changes often which worries me.
Every now and then my homepage changes to first something along the lines that Safe Search is on.. and now it changed to seek.mk, this worries me as I do not feel I have any viruses. I'm asking why it does that and if I should be worried.
http://www.ehow.com/how_6609141_remove-bearshare-spyware.html
I followed all prompts and they found nothing to suggest bearshare is on my computer.
But it is still automatically changing to become my homepage. -
PA30:Change and Display Mode
Hi Friends,
Can you Please provide me a solution for the Below Problem:
When I go to PA30 and try to CHANGE infotype 0001(Org Assmt),I get the fields "cost center,Position,job,org unit" in the Display mode I am not able to change those fields.
Where can i change(In the configuration) these fields to be changed from DISPLAY MODE TO CHANGE MODE.So that in PA30 I can change these fields in IT0001
Thanks In advance
Gopi PalletiHi,
You cannot change any of the field you mentioned in infotype 0001.
You can assign a position using action 0000 through PA40 or by using copy option infotype 0000 in PA30. This will be in edit mode.
Suggested to use PA40 so that all other relevant infotypes can also be updated accordingly.
Rest of the components (Objects Job, Cost Center, Org unit etc) has to be assigned to the respective position in PO13-->Relation ships.
Note: Take care of the dates.
Regards,
Pranitha
Reward if found Helpful -
We need some help with a requirement. We need to monitor HR infotype changes. We would like to be able to trigger a event like a change pointer. However, we are trying to stay away from mods to our system. We are needed fields from 0000,0001,0003,0006,0105. Most of the fields do not have Change Documents set and would required us to create a mod to flag the data elements. We also tried to trigger and monitor these changes in ZXPADU02 until we realized that once we get to 0003,0006,0105 in zxpadu02 we don't know what the person is inserting in that specific infotype, because the exit function module does not bring in information on changes to those infotypes. We would really like to be able to trigger off of a event without creating a mod. We would like to not have to run a program to read the logging files because we like the responsiveness and real time actions of triggering and not running a periodic program. We are trying to push these changes out of SAP.
Thanks>
Chris Rosecrans wrote:
> However, we are trying to stay away from mods to our system. >
> Thanks
Just in case you aren't already aware of it..
If you are on ECC6, you can enhance almost any Class/Function Module without the need for an Access key from SAP. you can insert a Pre/Post/Overwrite method..there are also several implicit enhancement points in each method/function module, where you can plug in custom code..
Also, this thread needs to be in the [Enhancements & Modifications |ABAP Switching, Enhancing, and Adapting Standard Programs; forum.
~Suresh -
Difference between Delta "Change Log" and "Active Table (Without Archive)"?
In BI7.0 environment, we perform our Delta loads (the DTP settings under the Extraction tab, there is a field called Extraction Mode and it's value is selected as "Delta") every day among all our DSOs.
There is a section called "Delta Init. Extraction From..." under the same tab in DTP, there are four radio buttons:
Active Table (With Archive)
Active Table (Without Archive)
Archive (Full Extraction Only)
Change Log
Then what is the difference between "Change Log" and "Active Table (Without Archive)" if both Extraction Mode is "Delta" for two Delta loads?
Thanks!Hi ,
The new options SP16 has are:(Chk Note 1096771)
Active Table (with Archive)
The data is read from the active table and from the archive or from a near-line storage if one exists. You can choose this option even if there is no active data archiving process yet for the DataStore object.
Active Table (Without Archive)
The data is only read from the active table. If there is data in the archive or in a near-line storage at the time of extraction, this data is not extracted.
Archive (Only Full Extraction)
The data is only read from the archive or from a near-line storage. Data is not extracted from the active table.
Change Log
The data is read from the change log of the DataStore object.
Delta will always be picked from change log table.Only during intialization you can choose between getting data from change log or active table.If you are doing the load first time and are initializzing delta in subsequent data targets, then pulling data from active table will get lesse volume of data then it would have got from change log table....All subsequent deltas will be picked up from the change log. And when we need to reload data into the data target (which would be a full load) - we use active table.
From change log : you can take below ones as targets
1) Cube 2) DSO with Addition as the update for the Keyfigures
From Active table: you can take below ones as targets
1) Cube ,if and only if, the records are never changes in the source once after creation
2) DSO with Addition as the update for the Keyfigures ,if and only if, the records are never changes in the source once after creation
3) DSO with Overwrite as the update for the Keyfigures ( incase deletions is not happening in the source system)
Pls check this link
http://help.sap.com/saphelp_nw70ehp1/helpdata/en/47/e8c56ecd313c86e10000000a42189c/frameset.htm
Regards,
CSM Reddy -
I have an iPad and iPhone. My husband has an iPad and iPhone. His iPad is under his own Apple ID, but his phone is under my Apple I D. Can I change his phone to his own Apple ID without losing things like his contacts and photos?
Create a new user account on the computer that he can log in to.
-
Change Logs for Infotypes !!
Hi,
How do i activate Logs for an Org Infotype ? Can I do this for Custom Infotype too ?
Thanks in Advance !!
NaveenHi Naveen,
Please refer the following steps in SPRO
Position Budgeting and Control ->Automatic Commitment/Budget Creation ->Basic Settings ->Activate Recording of Financing Relevant Infotype Changes ->Define Relevant Object Types for Change Log
Here, you can define the object types for which you want to monitor the changes
Position Budgeting and Control ->Automatic Commitment/Budget Creation ->Basic Settings ->Activate Recording of Financing Relevant Infotype Changes ->Define Infotypes Relevant for Change Log
Here, you can define the infotypes that you want to monitor.
Finally, make sure the change log is activated at the below step
Position Budgeting and Control ->Automatic Commitment/Budget Creation ->Basic Settings ->Activate Recording of Financing Relevant Infotype Changes ->Activate Change Log for Infotypes
I hope this helps you.
Regards,
Swapna. -
just updated iphone, it will not let me start up without changing my id-- so I changed it to email address like it asked and it wont take it saying its already in use,,, yes it is, its mine!! help
That error message means that your email address is already associated with another Apple ID. It could be tied to GameCenter, iTunes Store, or another Apple ID.
-
VTP change from server mode to transparent mode
Hi,
We have a VTP domain in which all switches are in transparent mode. However, several have the wrong domain name or mode. As a result, some errors are being displayed in the log. I would like to change the VTP configuration in those switches. They are all in a production network. Which would be the best way to do it without causing problems to the network?
Regarding the switches which are in mode server and have a wrong domain name, should I change firstly the mode to transparent and then the domain name? Is there any risk of losing the vlan configuration?
Thanks in advance.Disclaimer
The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
You write, all switches are in transparent mode, but also regarding those in server mode - i.e. which is it?
"Safest" would be to switch a server (or client) mode switch to transparent before changing domain name. If you switch domain name first, yes you expose having shared VLAN information changed. -
Way to see infotype screen without going PA20?
Hi Experts,
Is there a way to see just the infotype screen without going to PA20. I want to see the changes I am making using T588M and see which field has what technical field name and how the screen will look like when I make changes using T588m?
Thanks a bunch,
JESS..Hi,
You can also check screen painter through transaction SE51. Give the module pool name under u201Cprogramu201D and the screen number, select layout editor and display. If you click on any field, the technical name will appear in the u201Cnameu201D row above. Further, any field with u201C?u201D is a mandatory field.
Hope this helps.
Donnie -
Any problem in changing the update mode.
Hi Gurur's,
We have set Unserialized V3 update mode in R/3 production for 2lis_03_bf.
We are getting '0' records while running delta.
Now can we change the update mode to queued delta and run and for that what are the precautionary steps to be done.And will be the effect if we done like that happen.
Cheers,
Satish.M.R.Hi Satish
The diffrence between these 2 update modes are
Queued Delta:With this update mode, the extraction data is collected for the affected application instead of being collected in an extraction queue, and can be transferred as usual with the V3 update by means of an updating collective run into the BW delta queue. In doing so, up to 10000 delta extractions of documents for an LUW are compressed for each DataSource into the BW delta queue, depending on the application.
unserialized V3:With this update mode, the extraction data for the application considered is written as before into the update tables with the help of a V3 update module. They are kept there as long as the data is selected through an updating collective run and are processed. However, in contrast to the current default settings (serialized V3 update), the data in the updating collective run are thereby read without regard to sequence from the update tables and are transferred to the BW delta queue.
Please go through the below article
http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/5039632a-c398-2d10-0aaf-97167a3de753?QuickLink=index&overridelayout=true
You will get clear idea about how the data flow differs in this 2 update modes
Hope this helps
Regards,
Venkatesh -
Ring Control changes without a write to the ring control
I am experiencing a weird phenomenon. My application opens a main gui.
On the main gui is a ring control which allows our operator to choose the test mode that they want the tests to run in. This basically controls the way data is handled and the tests that can be run in that mode.
There is another ring control which allows the operator to select the test that they want to run.
Once the operator selects a test, there is a Run Test button on the main gui.
The issue:
The user selects a test to run then hits the "Run Test" button. Another gui pops up, the main gui remains open, but the second gui becomes the active gui. The test runs and the second gui closes making the main gui the active gui again. On several occassions, and without clicking anything the operator has watched the "Test Mode" Ring change it's value about 10 - 15 seconds after they ran the last test.
I have gone through my code and there is nowhere that I programatically write to this control. I only "GetCtrlVal" and dim or undim the control with "SetCtrlAttribute".
Any insight as to what could be causing this is appreciated. I am thinking there maybe a context switching issue here.
John O'C
Staff Test Systems Engineer
Woodward, Inc.
Skokie, Illinois, USA
"Life is not a journey to the grave with the intention of arriving safely
in a pretty and well preserved body, but rather to skid in broadside,
thoroughly used up, totally worn out, and loudly proclaiming...
Wow...What a Ride!"From my experience, this is often the result of using a panelhandle/control ID combination that don't belong together in a call to something like SetCtrlVal(...). In a large project, this can be challenging to track down. What I would look for is a call to SetCtrlVal(...) with the panelhandle of your main GUI with a control ID that is on some other panel. You can also look in the uir .h file(s) and search for the macros that have the same value as your ring control and see if they are being used inappropiately. Another way is to turn on "Break on Library Errors", as not all the calls with mismatched panelhandle/control ID combos will work so this may help you track down where they are located in the code. Hope this helps.
-
I tried installing a program but when i open logic and scan the audio units, it doesnt come up. Even if i change the bit mode, it still doesnt show up. I even tried restarting my machine..Can anyone help me or give me some ideas.
i just wanna get this plugin to work.Have you confirmed that the plug-in installed to one of the locations where Logic might find it? Most plug-ins go to /Library/Audio/Plug-ins/Components. Some (rarely) install to ~/Library/Audio/Plug-ins/Components (where "~" is your user folder). Look in both locations and see if the plug-in is actually there.
When installing plug-ins, if you are offered options as to what format to install, be sure to include Audio Units. Logic will not see other formats like VST, RTAS, AAX, TDM, etc. If you use other software that recognizes those formats, it's fine to install them too, just be sure you don't deselect Audio Units.
Finally, if you're sure the plug-in is installed to the right place, open the Audio Units Manager in Logic and check to see if the plug-in passed validation. Go to the main menu and choose Logic Pro > Preferences > Audio Units Manager. Check to see if your plug-in is listed there. If there's not a check mark next to it in the "Logic" column, that means it failed validation. If so, the "Compatibilty" column will tell you why. Keep in mind that if the AU is 32-bit, you have to launch Logic in 32-bit mode to see it here. Likewise, 64-bit plug-ins show up in the manager in 64-bit mode. -
Any way to get Illustrator CS5 to display full screen mode like Photoshop?
Is there any way to get Illustrator's screen modes to behave like Photoshop's screen modes?
One of the things I like most about Photoshop is the way it toggles from standard screen mode to "full screen with menu bar" to just "full screen".
For example, in Photoshop's standard mode, the window is no bigger than the size of the canvas. Why can't Illustrator do that?
And, is there anyway to get Illustrator CS5 to display the full screen mode where the background outside the artboard or canvas is black instead of white. Working in Illustrator for long hours, it would much easier on my eyes if the surrounding background could be black like in Photoshop.
Thanks very much in advance for any help,
- NickAt the bottom of the Tool bar is a toggle button (F) which will change the Screen Mode.
Maybe you are looking for
-
With newest IOS7, installed this morning, can no longer change just one time, a recurring event-like a monthly meeting. It used to ask if i want to change for this event only, or for all the events. How else can you change the time "just this once"
-
HP Photosmart 5514 e-All-in-O​ne Printer - B111h (Default Printer)
Trying to print a medicine list from "Documents"; printer makes lots of noise before trying to print and when it comes out of the printer, it's only a partial list. I printed something the other day and everything was fine. I've tried to pinpoint the
-
Accessing external SSD causes FCPX and entire computer to crash
Hello, I am running the latest Version of Final Cut Pro X on my 13 inch retina MacBook display late-2013 fully loaded, going @ Best For Retina. I am working on a project and every time I connect my media SSD via thunderbolt to the computer, and attem
-
Open quicktime files in same window
Hi there, as a matter of fact QuickTime is pre-configured to open files in a new window, which get's really annoying when playing a TV series. Is it possible to configure QuickTime to open new files within the same window, so that I don't have to man
-
Hi, Suddendly I'm not able anymore to login to a SunMC Server 4.0 (Patch 127683-06) via "es-start -c ". I know that it has worked with this patch and there haven't been any other patch/package installations. sunmcweb and es-cli do work without proble