LSMW for equipment bom kde
Can someone please specify the steps required to create an equipment bom lsmw
hi Alagasen
why don't you use standard object "create material BOM",change the transaction code from CS01 to IB01
and do the mapping and upload
regards
Seenu
Similar Messages
-
Hi,
I have 100 Equipments
Some equipment have 5 BOM items, Some have 3 BOM items. It varies
How i should create LSMW - Recording Method for this?
I need to create two LSMWs ?
Thnkshi Alagasen
why don't you use standard object "create material BOM",change the transaction code from CS01 to IB01
and do the mapping and upload
regards
Seenu -
Is there any standard BAPI to create Equipment BOM? Tcode - IB01
Hello,
I use that bapi for create BOM but not equipement BOM.
I find on forum, response wiche can help you :
Equipment BOM Upload BAPI
RFC / BAPI for Equipment BOM - IB01
http://wiki.sdn.sap.com/wiki/display/ABAP/ECCstandardBatchInputprograms
Thierry -
Tables or Logical database to create standard report for Equipment BOM?
Dear All
My client has requirement for the report with fields like to see the status of Equipment BOM(input of Equipment number in selection screen) or for Particular set of Materials(input of component number in selection screen) available stock quantity,storage location of stock,description of component,price of component,Pending PR of component(if any),Pending PO of component(if any) etc
I want to develop the report with standard infoset query instead of going for abap development.is there any logical database to map the report or what tables can i use for table joins??
Required sample report with fields as below
BOM Component
Stock available/Not available indicator
Description of Components
BOMQty/ UOM
Price
Part Number
Plnt
Sloc
Stock Qty
Bin
Pending PR
Pending PO
1000001121
YES
BEARING
NO
2000
ERS22
1000
MECH
4
A1
300012431
Regards
M.ManojkumarManoj,
The following is the tested solution.
Table join
Output
This figure shows the case of a Equipment BOM where 3 components are there. Installed Quantity are 4, 1, 1 respectively. Last two columns are showing the Storage Locations and the Stocks available.
Fields taken to output are
From STPO : IDNRK MENGE MEINS
From MARD LGORT LABST
As said before, more than this you can not do in SQVI. With this basic join in SQ02, using codes in Extras you can do much more.
Jogeswara Rao K -
Deletion flags for equipment BOM
Hi,
In equipment BOM header , there are 2 fields for deletion flag :
-one is set manually (the one on the right)
-the other set by the system (the one on the left).
Can someone explain to me how deletion flag indicator (on the left) work?
Thanks,
P.Hi,
To explain this i must say first there is a difference in the Deletion Flag (Right in Header) and Deletion Indicator(Left in Header).
In SAP term The deletion Indicator shows the item which has already been Deleted from the System and Deletion flag shows that the record has been flagged for deletion and will hence be Archieve (when, depends on the Archieving strategy followed in the company).
To explain the affect these will have is the Deletion Indicator will not allow you to use the and will show the error as the object has been deleted and is not in the system.
Deletion flag for BOMs
Indicator: this BOM will be archived during the next archiving run and, if necessary, deleted from the data base.
Where as the Deletion Flag will show that the object is ready to be archieved and is set to be deleted.
Deletion Indicator
Indicator showing that the BOM header or the BOM item has been deleted with reference to the change number.
Now there is another difference in the way we can amke the objects active from deletion flag anf the deletion indicator.
For Deletion flag you have to go to change mode and just remove or untick the deletion flag.
For Deletion indicator you have to go to Archieve table and pull the object back in to SAP system and it will then show only the deletion flag, which can be removed by the way explained above.
I hope this was helpful, if yes then please award points.
Regards
Anoop -
LSMW for Equipment characteristics Update
Hi,
I am having a LSMW program for Equipment Classification (Characteristics Value)Data upgrade created in ECC 5.0 . We have upgraded to ECC 6.0 EHP 4 Now. However this program was working fine in ECC 6.0 but while upgraded to EHP 4, I'm Getting following ErrorDisplayed whie creating Batch Input Folder.
BDC_INSERT, Transaction code .. is invalid.
The Recorded program for this as given Below.
Recording EQUI_CHAR EQUIPMENT CHARACTERISTICS LSMW
|
--- IE02 Change Equipment
|
|-- SAPMIEQ0 0100
| |
| |-----BDC_CURSOR RM63E-EQUNR
| |-----BDC_OKCODE /00
| ------RM63E-EQUNR
EQUIP_NO EQUIPMENT NUMBER
-- SAPMIEQ0 0101
BDC_OKCODE =KL
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
BDC_CURSOR ITOB-SHTXT
BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
-- SAPLCLCA 0602
BDC_CURSOR RMCLF-KLART
BDC_OKCODE =ENTE
RMCLF-KLART CLASS_NO CLASS NUMBER
-- SAPLCLFM 0500
BDC_CURSOR RMCLF-CLASS(01)
BDC_OKCODE =NEUZ
RMCLF-PAGPOS 1
BDC_SUBSCR SAPLCBCM
-- SAPLCLFM 0500
BDC_CURSOR RMCLF-CLASS(02)
BDC_OKCODE /00
RMCLF-CLASS(02) CLASS_NAME CLASS_NAME
BDC_SUBSCR SAPLCBCM
-- SAPLCTMS 0109
BDC_CURSOR RCTMS-MWERT(10)
BDC_OKCODE =BACK
RCTMS-MNAME(01) CHAR_1 CHARACTERISTICS 01
RCTMS-MNAME(02) CHAR_2 CHARACTERISTICS 02
RCTMS-MNAME(03) CHAR_3 CHARACTERISTICS 03
RCTMS-MNAME(04) CHAR_4 CHARACTERISTICS 04
RCTMS-MNAME(05) CHAR_5 CHARACTERISTICS 05
RCTMS-MNAME(06) CHAR_6 CHARACTERISTICS 06
RCTMS-MNAME(07) CHAR_7 CHARACTERISTICS 07
RCTMS-MNAME(08) CHAR_8 CHARACTERISTICS 08
RCTMS-MNAME(09) CHAR_9 CHARACTERISTICS 09
RCTMS-MNAME(10) CHAR_10 CHARACTERISTICS 10
RCTMS-MWERT(01) VALUE_1 VALUE 01
RCTMS-MWERT(02) VALUE_2 VALUE 02
RCTMS-MWERT(03) VALUE_3 VALUE 03
RCTMS-MWERT(04) VALUE_4 VALUE 04
RCTMS-MWERT(05) VALUE_5 VALUE 05
RCTMS-MWERT(06) VALUE_6 VALUE 06
RCTMS-MWERT(07) VALUE_7 VALUE 07
RCTMS-MWERT(08) VALUE_8 VALUE 08
RCTMS-MWERT(09) VALUE_9 VALUE 09
RCTMS-MWERT(10) VALUE_10 VALUE 10
BDC_SUBSCR SAPLCBCM
-- SAPLCLFM 0500
BDC_CURSOR RMCLF-CLASS(01)
BDC_OKCODE =ENDE
RMCLF-PAGPOS 1
BDC_SUBSCR SAPLCBCM
--- SAPMIEQ0 0101
|
|-----BDC_OKCODE =BU
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_SUBSCR SAPLITO0
|-----BDC_CURSOR ITOB-SHTXT
|-----BDC_SUBSCR SAPLITO0
BDC_SUBSCR SAPLITO0
Kindly Help me to resolve this issue. Thanks n Regards
Raj Verma
1Raj,
You had mentioned that you were using LSMW so i had given probable problem for LSMW. But now as you are saying its BDC i would request you to check back with your abap team. In code they might have written that whn a new value is entered, refer the old value and update it.
This can be the only problem just check back with them and your problem will be solved. -
Hi All,
Please let me know if there is any BAPI/ FM available for creating Equipment BOM (IB01 trancastion).
Thanks in advance
regards,
BoomaCheck sample code in:
http://scn.sap.com/thread/562325
Regards,
Sergio. -
Hello,
1. What is the Tcode to see Equipment BOM list ?
2. How to see a particular ERSA material is used in how many Equipment BOM
Thanks
PrasadAs described above, there isn't a BOM list as such.
However, you could look at the Equipment BOM Logical Database (CEC) via TCode SE36
This Logical Database can also be used in TCode SQVI or SQ01
PeteA -
Maximum Line items for Equipment BOM
Dear Experts,
Is there a limit to the number of line items of components we can have in equipment BOM. I am not able to add anything above 999. It doesnt show any error, but doesnot save any value after 999. Please let me if there is a work around.
Thanks,
BobyThe BOM item node number STPO-STLKN is an 8 digit field therefore I would imagine that you could have a maximum of 99999999 items..
But you could use multi-level BOMs which would allow you to organise your components better.
PeteA -
LSMW for equipment creation-Standard Batch/Direct Input
Hi,
We developed an LSMW with standard batch / direct input method for creating equipment masters.
We used Object =0400 ( equipment ) and method = 0001 ( batch input)
We maintained source structures and source fileds. In the source field , we maintained only those fields that we need from table IBIPEQUI but in the order given in this structure.
Also we maintained filed mapping and field convertion rules for the above source fields.
When we run LSMW step - Display converted data , we see that
Transactions Read: 1
Records Read: 1
Transactions Written: 0
Records Written: 0
Not sure what could have gone wrong?
Please provide some clues to the following questions.
1) Should the source structure be same as fields from stuc. IBIPEQUI and should it include all the fields in the source structure?
2) Is field mapping required or not ?
3) We are getting an error - transaction is not supported in direct input mode.
Thanks in advance
Rgds,
Rajesh1. Source fields are( same as IBIPEQUI structure ; the tab delimited file matches with these fields)
TCODE C(020) Transaction Code
RECORDNAME C(008) Record name
EQUNR C(018) Equipment
DATSL C(008) Valid On
EQTYP C(001) Equipment category
EQKTX C(040) EQKTX
BEGRU C(004) Authorization Group
EQART C(010) Technical obj. type
GROES C(018) Size/dimensions
INVNR C(025) Inventory number
BRGEW C(017) Gross Weight
GEWEI C(003) Weight unit
ELIEF C(010) Vendor
ANSDT C(008)
ANSWT C(017) Acquisition Value
WAERS C(005) Currency
HERST C(030) Manufacturer
HERLD C(003) Country of manufact.
BAUJJ C(004) Construction year
BAUMM C(002) Construction month
TYPBZ C(020) Model number
SERGE C(030) ManufSerialNumber
MAPAR C(030) ManufactPartNo.
GERNR C(018) Serial number
GWLEN C(008) Warranty end date
KUND1 C(010) Customer
KUND2 C(010) End customer
KUND3 C(010) Operator
SWERK C(004) Maintenance plant
STORT C(010) Location
MSGRP C(008) MSGRP
BEBER C(003) Plant section
ARBPL C(008) Work center
ABCKZ C(001) ABC indicator
EQFNR C(030) Sort field
BUKRS C(004) Company Code
ANLNR C(012) Asset Number
ANLUN C(004) ANLUN
GSBER C(004) Business Area
KOSTL C(010) Cost Center
PROID C(024) PROID
DAUFN C(012) Standing order
AUFNR C(012) Order
TIDNR C(025) Technical IdentNo.
SUBMT C(018) Construction type
HEQUI C(018) Superord. Equipment
HEQNR C(004) Position
EINZL C(001) Single installation
IWERK C(004) Planning plant
INGRP C(003) Planner group
GEWRK C(008) Main work center
WERGW C(004) Plant for WorkCenter
RBNR C(009) Catalog profile
TPLNR C(030) Functional Location
DISMANTLE C(001) DismIndic.
VKORG C(004) Sales Organization
VTWEG C(002) Distribution Channel
SPART C(002) Division
MATNR C(018) Material
SERNR C(018) BOM explosion number
WERK C(004) WERK
LAGER C(004) LAGER
CHARGE C(010) CHARGE
KUNDE C(010)
KZKBL C(001) Load records
PLANV C(003) PLANV
FGRU1 C(004) FGRU1
FGRU2 C(004) FGRU2
STEUF C(004) Control key
STEUF_REF C(001) STEUF_REF
KTSCH C(007) Standard text key
KTSCH_REF C(001) Std text referenced
EWFORM C(006) EWFORM
EWFORM_REF C(001) EWFORM_REF
BZOFFB C(002) Ref. date for start
BZOFFB_REF C(001) BZOFFB_REF
OFFSTB C(007) Offset to start
EHOFFB C(003) Unit
OFFSTB_REF C(001) OFFSTB_REF
BZOFFE C(002) Ref. date for finish
BZOFFE_REF C(001) BZOFFE_REF
OFFSTE C(007) Offset to finish
EHOFFE C(003) Unit
OFFSTE_REF C(001) OFFSTE_REF
WARPL C(012) Maintenance Plan
IMRC_POINT C(012) Measuring point
INDAT C(008) Inverse date
INTIM C(006) Processing time OC Workbe
INBDT C(008) Start-up date
GWLDT C(008) Guarantee
AULDT C(008) Delivery date
LIZNR C(020) License number
MGANR C(020) Master warranty
REFMA C(018) REFMA
VKBUR C(004) Sales Office
VKGRP C(003) Sales Group
WARR_INBD C(001) Inbound warranty
WAGET C(001) Warranty inheritance poss
GAERB C(001) Indicator: Pass on warran
ACT_CHANGE_AA C(001) ACT_CHANGE_AA
STRNO C(040) STRNO
DATLWB C(008) Date Last Goods Movmnt
UII C(072) UII
IUID_TYPE C(010) IUID Type
UII_PLANT C(004) Plant Responsible for UII
2, source structure is assigned to target structure IBIPEQUI
3. In the assign files step - all settings given above are correctly maintained.
4. Field mapping
TCODE Transaction Code
Rule : Default Settings
Code: IBIPEQUI-TCODE = 'IE01'.
RECORDNAME IBIP: Name of the Data Transfer Record
Rule : Default Settings
Code: IBIPEQUI-RECORDNAME = 'IBIPEQUI'.
EQUNR Equipment Number
Source: ZIE01_002_SOURCE-EQUNR (Equipment)
Rule : Transfer (MOVE)
Code: if not ZIE01_002_SOURCE-EQUNR is initial.
IBIPEQUI-EQUNR = ZIE01_002_SOURCE-EQUNR.
endif.
DATSL Date valid from
Source: ZIE01_002_SOURCE-DATSL (Valid On)
Rule : Transfer (MOVE)
Code: if not ZIE01_002_SOURCE-DATSL is initial.
IBIPEQUI-DATSL = ZIE01_002_SOURCE-DATSL.
endif.
EQTYP Equipment category
Source: ZIE01_002_SOURCE-EQTYP (Equipment category)
Rule : Transfer (MOVE)
Code: if not ZIE01_002_SOURCE-EQTYP is initial.
IBIPEQUI-EQTYP = ZIE01_002_SOURCE-EQTYP.
endif
When I read data with 1 record uploaded ( in the assign fields step , I did not choose "fields names at start of file" and also saved the file with tab delimited text format without field names), it shows as
Transactions Read: 2
Records Read: 2
Transactions Written: 2
Records Written: 2
I uploaded only one record but it reads as 2 records and can not figure out why 2 records?
Also when I checked display converted data , it shows 2 records .
First record shows
TCODE Transaction Code IE01
RECORDNAME IBIP: Name of the Data Transfer Record IBIPEQUI
EQUNR Equipment Number
DATSL Date valid from 05072010
EQTYP Equipment category H
EQKTX Description of technical object PNEUMATIC PIPE BENDER
BEGRU Technical object authorization group
EQART Type of Technical Object MECH-PRESS
GROES Size/dimension 1000X500X1500MM
INVNR Inventory number
BRGEW Gross Weight : IBIP Character Structure 50
GEWEI Weight Unit KG
ELIEF Vendor number
ANSDT Acquisition date
ANSWT Acquisition Value: IBIP Character Structure
All the fields following this , are blank.
2nd record shows
TCODE Transaction Code IE01
RECORDNAME IBIP: Name of the Data Transfer Record IBIPEQUI
EQUNR Equipment Number 2009
DATSL Date valid from
EQTYP Equipment category S
EQKTX Description of technical object 1006324
BEGRU Technical object authorization group
EQART Type of Technical Object
GROES Size/dimension 20100406
uploaded values are jumbled in 1st and 2nd record.
Hope to receive your valuable ideas for finding out the reason and corrective action required.
Rgds,
Rajesh
I
Edited by: Rajesh63 on Jul 6, 2010 10:37 PM -
LSMW for Workcenter, BOM & Routings
Hello people,
I am new to LSMW. We are on ECC 6.0 & all master data is in Plant X, now we want all master data in plant Y. Same plant but we are creating virtual plant. So all master data will be as it is.
I need to copy existing Workcenter, Routing, BOMs from Plant X to Y.
for example If i do manually, CR01 - copy with reference..it works
1> should i go with Batch input recording and record copy with reference for LSMW?
2> or Standard SAP program for LSMW?
Can you please tell me the detail process... It would be great help!
ThanksHello,
Please look into the below link for more details on LSMW:
http://help.sap.com/saphelp_erp60_sp/helpdata/en/87/f3ae63e68111d1b3ff006094b944c8/frameset.htm
Also for BOM transfer there is already thread:
BOM Uploading through LSMW
Hope the information is useful
Regards -
LSMW direct input method - Equipment BOM
Hi Experts,
We have already written program for equipment BOM master in LSMW direct input method. I do not know about this direct input method.
Here they have maintained 2 source structures and relavant source fields. one for BOM header and other for BOM items. The first field they maintained is LINK in both the source fields. I really do not know what that field is all about. I checked in step specify files and found that they have previously mentioned two files, one for BOM header and other for BOM items. but when I tried to save in this step it gives me error that " No logical path specified". Can anybody tell me what is this error is all about.Please heip me to get out of this problem.
Thanks and best regards,
PraveenHi praveen,
LSMW does not accept two files.
In the step create source strcture
crte one structure with BOM header like with ZBOM_H.
Under that create another structure for item ZBOM_I.
ZBOM_H
ZBOM_I like this structure will will be.
In the step source fields.
crate onne variable with indicatoe header.While creating the variable we have field 'identify field content ' field in pop up screen 'H'.
assign all header files under identifier 'H'.
then under ZBOM_I create identifier with 'I'.
Assign all the item fields to this.
then map the fields.
In the file should be H header fields.
I item fields.
I
I.
Then Header .It should be like this.
in saptechnical u will get the examples go though them once.
Thanks -
LSMW Batch Input Recording for Create BOM
Dear All,
I want to do LSMW for Creating BOM using Batch Input Recording,
I know that i have to make 2 time Recording, first for the BOM Header and second for the BOM item
For the BOM header i have done it, but for the BOM item i got some trouble with the item number (POSNR),
when i run the LSMW, for the first item (item 0010) was success, but for the item 0020, it can't work and i got error
message " NO BATCH INPUT FOR SAPLCSDI 0150"
How is the recording step by step for BOM Item so the Item number can increase well?
Very need your help,
Regards,
MarufatHello Santosh,
Thanks for the reply,
I already check in SM35 where i also thought that the main problem is about adding the new item number,
but when i tried to do repeat recording, i can not find any entry for adding the line item, so the line item after 0010 cannot be input
Is there any solution?
Regards,
Marufat -
How to find component details for the equipment BOM
Dear All ,
I have a requirement ..I need to find all the component numbers for the equipment BOM. Can anybody pls help me in finding a table containing this information. I check in tcode IB02,IB03 but I am not able to find the database table containing this information.
Regards,
sap_code.Hi, Main table for equipment BOM is EQST. You can get the details from STPO (Item) and STKO (Header). You can use the FM CSAI_BOM_READ. Here u need to pass the header details and CSIN-STLTY = E " Equipment BOM.
Thanks
Subhankar -
To find 'Maintenance Work Center' for Equipment (without Production order)
Hi,
I have a Report for - 'Equipment BOM' - IB03.
Problem: How to find the 'Maintenance work Center ' For Equipment ? (IE03--> Organization > Responsibility> Main. W.Cntr)
[ Note: For Client --> It's not necessary that each Equipment has Production Order, Few Equipments are taken only for Repair purpose, Equipment is there in table - EQUI,
So - Not possible to fetch from AUFK, HIKO or any other order tables. ]I have a Report for - 'Equipment BOM' - IB03.
Problem: How to find the 'Maintenance work Center ' For Equipment ? (IE03--> Organization > Responsibility> Main. W.Cntr)
[ Note: For Client --> It's not necessary that each Equipment has Production Order, Few Equipments are taken only for Repair purpose, Equipment is there in table - EQUI,
So - Not possible to fetch from AUFK, HIKO or any other order tables. ]
EQUZ-GEWRK has the main work center. Pass the equipment number and valid-to date to get the main work center.
Cheers
Sujay
Maybe you are looking for
-
Data Connection to MS-SQL using Windows Auth from untrusted machine
We have an Excel Spreadsheet that uses a Data Connection to a MS-SQL database. The database server is joined to our domain, and Windows Authentication is enabled. Here is a sample of the connection string (with revealing info obfuscated): Descriptio
-
How to transfer purchased books to another account
Please explain me the procedure to transfer my previously purchased files to a new account.
-
Getting error while starting application services.
HI, I have installed 12i application but while starting the application services getting below error. libopmnoraclenls.so: unable to open library main: NLS initialization failed!! libopmnoraclenls.so: unable to open library main: NLS initialization f
-
Oracle BI Installation OUI-10185
Hello Guys, I am trying to install oracle on my Toshiba laptop dual core 2GB RAM. At some step about 14% completed installation, some files can be found in disk 4, but I just continue. At about 44%, I get an error below: OUI-10185: +"...\Disk4\stage\
-
I can't download music to my iPod mini