LSMW Measuring Point Delete

Hi,
I have tried creating an LSMW in order to delete a measuring point associated to an equipment using IE02 and/or IK05. I would not like to delete all of the measuring points by using the select all buton and delete. Therefore I am using the tick box to select the measuring point I would like to delete. However, the LSMW does not recognise that I am selecting a measuring point.
Any work around or any other option?
Regards,
Nikolai

IK02 does not enable you to delete the measuring point, however it allows me to change the decimal places which is what I wanted. CT04, does not allow you to change the decimal point of the characteristic if it is already assigned to an equipment.
Thanks for your help.

Similar Messages

  • Deletion of Measuring points from the Notification

    Hi
    I have created a notication and attched manully some measuring point. (Extras-->Measuing document, New Entries and added the measuing points). I want to delete the measuring points from the notification. It displayes the msg "1 MeasDocs cannot be deleted as they already exist in the database"
    Note:The measuring points are not attached to the tech object.
    Please let me know how can we delete this MP's or what alternative i need to follow.
    The system msg display below:
    HELP msg "
    1 MeasDocs cannot be deleted as they already exist in the database
         Message no. IR 018
    Diagnosis
         You are trying to delete measurement documents that the system has
         already written to the database.
    System Response
         The system cannot perform the function.
         You can only delete measurement documents online at the creation stage.
         Once you have saved a measurement document, you can only delete it using
         a special reorganization program."
    Thanks & regards,
    Mujeeb

    hi
    For using archiving programme take help of basis help see firstly create programme on archiving object
    PM_IMRG whcih is the object for measuring document then by ebtering this prepare the archving file run in test mode
    then deletion of data with date wise reading  in test mode follwed afterwards.
    you have to confirm the data before the deletion
    Regards
    chandrashekhar

  • Update Measurement Points on Functional Locations

    Hello Experts,
    I need create a custom program to update (add/delete/change) the measurement point's POSITIONS on functional locations. Basically the users want to clean up the functional locations which have some wrong data in them. Since I am very new to this functionality area, Can anybody please let me know - Is there a FM/Bapi to update the Measurement Point Positions on Functional Locations?
    I appreciate your help.
    Thanks.
    Edited by: sey ni on Mar 7, 2011 4:49 PM

    I think I will have to write a BDC on IK01/IK02 transactions. Not sure, if we have a better solution.

  • Measuring Point Description Change-MassChange

    I have several (hundreds of ) Measuring points which i need to change .The fields to be changed include the Measuring position    and measuring descriptions. Since its a time consuming process to change individual record, can some one suggest any mass change transaction in PM with which i can achieve this changes without much time as in case of individual changes.
    Please suggest some direct method in order to avoid any BDC or LSMW.
    Thanks
    Murad Shaikh

    HI  Murad
    As such there is no standard T code for carrying out mass changes for measuring points except list editing (IK08) through which you can do it by selecting one by one. Since the fields you wants to change are free text type & will vary from one measuring points to other its not logical also. Better to do it through LSMW using recording IK02 its very easy & will take 10min to create one LSMW.
    Shakti

  • Measuring point as counter mass maintenance

    Hi,
    I have created some 500 equipments through BDC. But I forgot to put a tick (X mark in template) against field u2018Indicator to Show that Measuring Point Is a Counter.
    How to put a tick on that field in mass?? Other wise I will have to go to T code IE02 500 times and put a tick manually.
    Pls guide.
    Regards.

    Hi Dear,
                 You can use the LSMW for the T-Code IE02, Recording Methord.
    That can serve your Purpose.
    Regards,
    Yawar Khan

  • CS module - Measuring Point

    Dear All,
    How to delete Measuring point of an equipment for which already measuring document is created?
    Regards,
    Samir

    Dear Samir,
    You can inactive the measuring point so that further measuring document creation is not possible. And it be available in equipment for history.
    Follow the steps:
    1) Run the transaction IK02.
    2) Enter the measuring point number.
    3) Select the following path: Measuring Point (Menu Bar) ->   Functions->    Active<-->Inactive-> Inactive
    4) Try for creating meas. doc., it will not be possible for this meas. point.
    Regards,
    Sundar Desai

  • Removing of the Measuring  point and superior equipment

    Hi,
    Can any one tell me the steps to followed for removing and setting og deletion flag for measuring point and superior equipment.
    I ran thr Tcode IK05 and deactivated it is it sufficient to do so.please help me.
    Regards,
    Yashwanth

    hi
    why you want to deactivate the measuring point ,if you have created a maintenance plan you can deactivate the maintenance plan so that system will not generate the maintenance call object.
    or it is better you deactivate the equipment itself if you have done that you cannot able to enter further measurement documents for measuring point
    regards
    thyagarajan

  • Archieving the measurement points

    Hi friends
    I would like to know how to archieve the measurement point . Unfortunately we have created the counter in production system without requirement. Now we want to remove the same. But we are not finding the object in SARA to remove the same.
    Please help on this
    Regards
    Thenna

    Hi
    Why dont you go for Deleting for the Measurement point for Equipment or FL in change mode IE02 or IL02 then press Shift+F2
    If you created any Measurement documents for above Measurement Point the first you have to Archiev the them using Object PM_IMRG.Then go for deletion of Measurement point
    Regards,
    Rakesh

  • Function Modules for creation of characteristics and Measurement Points

    Hello everybody
    I'm new in ABAP (trainee) and especially the use of characteristics. I'd be very happy if somebody could help me :).
    Can anybody out there with some experience in creating characteristics and measurement points tell me how to create them with function-modules or by changing database tables?
    I'm happy about every hint and ready to give some reward points.
    Best Regards,
    Steffen

    FM and TABLES
    http://72.14.235.104/search?q=cache:71IXBMWcX_8J:reflexcontracts.co.uk/SAP_R3_QUICK_REF.xlsupdatetable+tse05&hl=en&ct=clnk&cd=1&gl=in
    FUNCTION MODULES
    http://www.erpgenie.com/abap/functions.htm
    http://www.sapdevelopment.co.uk/fmodules/fmssap.htm
    http://www.erpgenie.com/abap/index.htm
    http://www.geocities.com/victorav15/sapr3/abapfun.html
    Rewards if useful..........................
    Minal

  • Triggering of Preventive Maintenance based on Measuring Point

    Hi,
    I have set measuring point & defined upper range limit and lower range limit. Now I want to trigger preventive maintenance, based on reading enter against measuring point specifically if measuring point reading is above or below defined upper range limit or lower range limit.
    Letu2019s say example, If 10 and 5 is upper range limit and lower range limit, now in this case creation of notification / main order if user has enter measuring point value more than 10 or less than 5.
    Regards,
    Dipen Shroff

    Hi,
        You can do it via Condition Based Maintenance ..
    IMRC0001- U can use this User exit
    http://help.sap.com/erp2005_ehp_04/helpdata/EN/a7/fa4c988f6611d29e8a0000e8323350/frameset.htm
    regards
    pushpa

  • Auto Update of measuring point/document

    Dear all,
    I have one issue over here.Measuring point/document is not updating automatically after productiuon order confirmation . I tried with following steps
    1) Created the equipment as test equipment -->created measuring point as a counter ---> maintain the usage value formula SAPF02 in the PRT tab . Unit of measurement for the characteristics and base unit of measure of material are same
    2) Then i have assigned this eqipment as a PRT in the routing of material .
    Which steps i am missing
    Thanks

    Hi
    I had faced the same problem  when I used SAPF02 then I did following changes.
    Created formula like SAP_09 * PRTSTD / SAP_08
    SAP_09 : Operation Qty
    PRTSTD : PRT Standard Value
    SAP_08:   Base Qty.
    Also make sure the measuring point category should me T in IK02( PRT life counter)
    Regards,
    Raj

  • Maintenance Order through Measuring Point

    Dear all,
    I want to know whether it is possible to create the maintenance order on the basis measuring point .
    I know how to create the order on the basis of measuring counter.
    Is there any procedure to create the maintenance Order through measuring point as done in case of counter?
    kindly provide the solution for Creation of Maintenance Order using Measuring Point..

    Really very thanks for the solution.
    I have one more query, we can create the measuring point using the t.code IK01.As you told we have to create the measuring point with upper and lower range.
    Is that we have to create 2 measuring point for upper as well as lower range or in one measuring point it is possible to accumulate both the upper and lower range.
    If it is possible to accumulate both the upper and lower range in one measuring point then kindly provide the procedure.
    Thanks in advance.

  • Measuring Point Status.

    Dear All Consultants,
    I have scenario for warranty services, so I define master warranty with to conditions “years - kilometer reading”.
    The problem is while assigning master warranty to equipment master system gives me this error {could not determine the status for measuring point 000000000212 at date 11.06.2007      
    Message no. BG212   } 
    Why this message appears and how to solve it.
    It is only warning message but it assume that the warranty expired.
    Waiting your kindly replay.
    yasser.

    Hi,
    Please refer the link below
    http://help.sap.com/saphelp_46c/helpdata/en/5a/3efb377409bd5ae10000009b38f889/frameset.htm
    as you might have not defined first counter.
    Enjoy SAP…
    Don’t forget to give points if its useful ans.
    Namskar
    Ketan Dave

  • Cannot create "Digital" measuring points on Work Manager 6.0

    Hi All,
    I am attempting to create "digital" i.e. Pass/Fail measuring points in Work Manager 6.0. I can enter readings as shown below but when I execute a sync, the error message below is shown:
    I can use the same measuring point in SAP via IK11 as shown below to create a measuring document using valuation code only. However, the Work Manager requires a numeric characteristic to be added and the "no reading" checkbox to be ticked.
    Any help would be greatly appreciated.
    Thanks,
    Jonathan

    Hi Michael,
    I tried setting it up with just the two values (0-fail and 1-Pass) and I'm still running into errors. If you could take a look I'd be grateful.
    Set up code group with two values:
    IK11 allows just the valuation code to be used:
    On the device:
    As far as I can see this should work but it still creates the same error as previously. Ideally it should work as IK11 and allow the user to select from multiple valuation codes but it appears to still require a characteristic.
    One option I tried is to assign a characteristic in addition to the the valuation code and use a 0 reading. This works but is a "workaround" solution in comparison to IK11.
    Any help would be really appreciated.
    Thanks,
    Jonathan

  • Screen enhancement in display measuring point (ik07) and ik02

    Hi experts,
    Can anybody please help in determining userexits for screen enhancement of ik02 transaction. I need to add block to measuring point details.
    and also i need selection screen input parameters to display at the bottom of ik07 tcode.i had inserted the selection screen parameters at the top of screen in ik07 but i need it at last. how can it be inserted there.
    PLZ HELP!!
    screen shot of ie02 for referenece....

    Hello Jared,
    Have a look to this :
    http://help.sap.com/saphelp_crm50/helpdata/en/20/a4ffee7e0fcc4ebb7e5466d3903d38/frameset.htm.
    Regards,
    Frédéric

Maybe you are looking for

  • ITunes stuck on repeat song

    I clicked on Controls > Repeat > One last night to repeat a song. Once I was finished I clicked on Controls > Repeat > Off, which is now ticked in the menu. However, iTunes is still repeating any song that is currently playing. I tried to click on >O

  • Report for public access

    Hello there, I would like to create reports based on specific projects. But when I open the template within PWA, it doesn't show my lready published projects. Why not? Further I'd like to make the reports available for public, but it seems that I am

  • I need a file for EPLAN P8 Version 2.4

    My problem is that I need a file for EPLAn P8 about NI USB-6501.

  • Data source for reports

    hi all, we r using 10g application server along with the reports service to deploy J2EE application The data source for the application is specified using the JNDI lookup Is it possible to use the same strategy for reports as well. i.e., we are using

  • Mountain Lion Install Issue - Bootcam partition cant boot up!

    After installing Mountain Lion OS, I experienced startup problem with my Bootcam partition. I saw blue screen after rebooting the Mac with error message " process1_initialization_failed " after installation complete. What can I do to recover my Bootc