Maintenence for measuring point
hi,
i am having clear idea about what is measuring point and counter and how to asign to a equipment.my question is how to give regular maintenece for measuring point or counter. how to calibrate that the measuring point is working properly...................(like preventive maintenence plan)..is it possible ?
regards
muthuraman.d
Either
Go to K11>edit>change gr counter
or
IK12 >enter>measuring document->function>reversal indicator-->set
check what happens
Regards
Sujit
Similar Messages
-
Table for Measuring point Reading.
Dear Experts,
Please guide where can I find the database table for measuring point reading values namely READC which is a part of RIMR0 structure, for using in developemts.
Regards
Jogeswara Raohi
check in IMRG table, you can find the values in SI unit . convert the same using Functional module. consult with your technical team
regards
thyagarajan -
External number range for measuring point
Hi experts,
How to assign external number range for measuring point ?
Regards
ShashiI have just checked and the measurement point number is linked directly with tthe object for eaxample equipment and when I tried this I got the same result the system defaults the number based ont he internal number range.
This being the case what is the business requirement that you need to use external numbering as this may help and someone may be able to assist either with an answer to the problem or an alternative solution.
SAP documentation as follows:
Create Number Ranges for Measuring Points
In this step you define number ranges for measuring points.
Notes
As the numbers for measuring points are assigned internally, you should work with the standard settings. If you want to make changes, you should always use number range 01.
Jim
Edited by: JamesPetrie on Feb 28, 2012 2:45 PM -
What is Make System Settings for Measuring Points and Measurement Documents
Dear PM Guru's,
i have doubht on the above customization section? in which situations we can activate or create new one ? whats its importance, how its impacts on our business scenarios. please suggest me and help me. Now i am in realization phase i am not observed much more difference with this check box .
i hope i will get the answer very soonly, and thanks to all of the PM gurusHi,
<< Moderator message - Cut and paste response from http://www.consolut.com/en/s/sap-ides-access/d/s/doc/YY-OLI0IMRCCUST removed. Plagiarism is not allowed in SCN >>
Regrds
Jitender
Edited by: Rob Burbank on Jun 6, 2011 10:53 AM -
Measuring Point Status.
Dear All Consultants,
I have scenario for warranty services, so I define master warranty with to conditions years - kilometer reading.
The problem is while assigning master warranty to equipment master system gives me this error {could not determine the status for measuring point 000000000212 at date 11.06.2007
Message no. BG212 }
Why this message appears and how to solve it.
It is only warning message but it assume that the warranty expired.
Waiting your kindly replay.
yasser.Hi,
Please refer the link below
http://help.sap.com/saphelp_46c/helpdata/en/5a/3efb377409bd5ae10000009b38f889/frameset.htm
as you might have not defined first counter.
Enjoy SAP
Dont forget to give points if its useful ans.
Namskar
Ketan Dave -
Measuring Point Description Change-MassChange
I have several (hundreds of ) Measuring points which i need to change .The fields to be changed include the Measuring position and measuring descriptions. Since its a time consuming process to change individual record, can some one suggest any mass change transaction in PM with which i can achieve this changes without much time as in case of individual changes.
Please suggest some direct method in order to avoid any BDC or LSMW.
Thanks
Murad ShaikhHI Murad
As such there is no standard T code for carrying out mass changes for measuring points except list editing (IK08) through which you can do it by selecting one by one. Since the fields you wants to change are free text type & will vary from one measuring points to other its not logical also. Better to do it through LSMW using recording IK02 its very easy & will take 10min to create one LSMW.
Shakti -
SAP PM: Measuring Point External Number
Dear Sir,
Is it Possible to assign Extenal number to Measuring Point?
Regards,
MohanHi,
I dont think there is a way for your requirement. Anyhow the following Enhancements are available for Measuring points/Document. You could check,
Exit name
Short text
IMRC0001
MeasPoint/MeasDoc: Exit before update (after COMMIT WORK)
IMRC0002
MeasPoint: Menu exit for customer-specific function
IMRC0003
MeasDoc: Menu exit for customer-specific function
IMRC0004
Measure.doc.:Exit according to stndrd checks for new mes.doc
IMRC0005
Measure point: Exit in AUTHORITY_CHECK_IMPT
|----
Hope this may be useful for you,
Regards,
Prasobh -
Removing of the Measuring point and superior equipment
Hi,
Can any one tell me the steps to followed for removing and setting og deletion flag for measuring point and superior equipment.
I ran thr Tcode IK05 and deactivated it is it sufficient to do so.please help me.
Regards,
Yashwanthhi
why you want to deactivate the measuring point ,if you have created a maintenance plan you can deactivate the maintenance plan so that system will not generate the maintenance call object.
or it is better you deactivate the equipment itself if you have done that you cannot able to enter further measurement documents for measuring point
regards
thyagarajan -
Dear all,
I know that external number range is not possible for measuring point. But in the system while creating measuring point, internal number range is assigned though it's not been saved.
Can anyone help me?
Regards
KarthikYa I have defined but I am not having doubt in the number range definition. Suppose if I ll create one measuring point with the number 1750(say) and I wont save it and came back. Then again I ll enter and the number should be 1750 but it ll show as 1751 (i.e.,) increasing the number range for measuring point. Can you tell me why this happens?
Regards
Karthik -
Measuring points check in IE01 / IE02
Dear all,
When user create or change an Equipment (IE01 / IE02) , the user should input field in Measuring points/counters.
Is there any Exits or BADIs for this transaction.
Thanks,
IkrarHi,
Read the documentation of customer exit component EXIT_SAPMIEQ0_001.
In program SAPMIEQ0 (Equipment change), on click on save button:
1) In you customer exit, read data from measuring points program, i.e. check LIMR0TOP include of function group IMR0 to identify the internal table / structures that contain the data for measuring points in program SAPLIMR0 screen 4110. This way you would come to know if the user has entered data for measuring points. If not, error out.
you can use the syntax using field symbols to read data from other program:
Sample code (not related to measuring point program.
DATA : var1 TYPE char25 VALUE '(SAPLIMSP)ISSM[]'.
DATA : var2 TYPE char25 VALUE '(SAPLIMSP)SCRGNTAB[]'.
FIELD-SYMBOLS: <fs_issm> TYPE ANY TABLE,
<fs_grtab> TYPE ANY TABLE.
ASSIGN (var1) TO <fs_issm>.
ASSIGN (var2) TO <fs_grtab>.
Best Regards,
Shyam
Edited by: Shyam Khemani on Jun 15, 2011 11:58 AM -
Measurement range limits in creating measuring point
Hi,
i'm creating a measuring point where i need to enter the measurement range limits i.e upper range limit and lower range limit.
Can anyone let me know where exactly the values are getting stored i.e table
or any function module available to get lower range limit and upper range limit
Pls let me know if anyone has any idea
ThanksHi Taran,
Could you please tell me how did you load the Upper and Lower limit range for measuring points...
Thanks,
Geetha -
Functional module to Copy measurement points from one equipment to another
HI,
Please give some body function module to Copy measurement points from one equipment to another which is not assign to functional location.To Copy Measuring Points from one equipment to another , Go to transaction IE10 and copy all the relevant data that need to be copied Check the measuring point check box, it would copy the characteristic for measuring point to the newly created equipment and would create a system generated number for the measuring point. Both the measuring points would have the same characteristics and if they are attached to each other in a hierarchy then the measurement document readings could also be transferred from one measuring point to another.. You could use the following Function Module "EQUIPMENT_COPY" to copy the measuring point from one equipment to another if equipment has already been created.
Regards...
Edited by: Usman Kahoot on Jun 9, 2010 2:37 PM -
Hi Experts,
I need to read measurement points asssigned to an order( it's functional location).
We tried RFC MEASUREM_DOCUM_READ_TO_ORDER but it returns measurement documents
(readings).
In Our requirenment, the order is newly created and no measurement documents exists.
we need to give all the measurement points (only) that exists against the order( it's functional location)..
Could you please help in this.
Please suggest any table/RFC.
RohitHope this thread would be helpful,
[BAPI for measuring point; -
Hi all,
Im trying to use the <b>PM_MEASUREMENT</b> DataSource. It works pretty well with Measuring Points linked to Functional location. However, I have some <b>Measuring Points</b> that are linked to <b>Equipments</b> and those <b>Equipments</b> have no connection to Functional <b>Location</b>. For <b>these Measuring</b> Points no data is being extracted at all.
Is there any restriction with the DataSource PM_MEASUREMENT that makes it only to extract data for Measuring Points linked to Functional Location?
If not, does any of you have any idea about what is going on here?
Thank you very much,
ClaudiomarThanks for your replies.
Saurabh: High volumes of serialized products are produced that are serviceable under warranty.
We are creating Serial Numbers for each model of the Product. We can attach Master Warranty and capture Warranty period for each Serial Number. But for creating Measuring Point / Counters, I have to generate an "Equipment Number" (via the Equipment View) for each Serial Number. If it is possible to do the same without creating Eqpt Num it will help.
Pete: I checked that link you had shown. But in T Code IQ01, I find Serial Number is not figuring in the list "Measuring Point Object (Obj.Categ. in Gen.Status Management)" and there is no IMG set up for this.
Request clarifications pls.
Thanks.
Raj -
Making system settings for measurement documents and measuring point
What is the significance of making system settings for measurement documents and measuring point in spro?
Edited by: Pallavi Kakoti on Jul 14, 2011 1:23 PMHi,
<< Moderator message - Cut and paste response from http://www.consolut.com/en/s/sap-ides-access/d/s/doc/YY-OLI0IMRCCUST removed. Plagiarism is not allowed in SCN >>
Regrds
Jitender
Edited by: Rob Burbank on Jun 6, 2011 10:53 AM
Maybe you are looking for
-
Create a ALV report with fields editable and entry to be saved in ztable
Hello Experts, I have created the ALV report which has two of the fields editable. Now whenever user puts an entry in the ALV it has to be saved in the ZTABLE. The report is displayed with editable fields but i'm not sure what has to be written in th
-
I can't get the Firefox tab in order to access all the choices there. Where is it?
In the Mozilla support, it keeps telling me to click on the orange Firefox tab at the top of my screen. I don't have one and can't find how to make it appear. Any advice?
-
Standard Projects Template report
Hi All, Is there a report I can use to view created Templates for Standard Projects/WBS? rg
-
LOUD low battery beep on Envy M6 laptops
everybody complain about it what will hp doe to help us!!we are student and we cant bring our laptop to school because of that horrible noise i try to speak with a hp technician and he told me to go on the sound setting or on the battery setting noth
-
Bapi,idoc,user exits
hi, im learner i want to need some idea in user exits,bapi,idoc any body having documents on above topics plz to send me...............plz