Major : PSU_REDUNDANCY Redundancy Lost for BE6K UCS C220 M3S
Hello Team,
We have several UC deployments based on UCS C220 M3 servers (the famous BE6K).
I'm not coming from systems background, I'm rather a Voice guy.
In fact, the BE6K UCS C220 M3 is shipped by default with only one Power Supply.
However, in the CIMC, we find many times that an alert is raised for Power Supply redundancy and the system LED turns to solid Amber.
Here's the alert : PSU_REDUNDANCY: PS Redundancy sensor, Redundancy Lost was asserted
We don't understand why this alert is raised when we already know that the BE6K server only contains one PSU ?
Is this a true problem or a false alarm ?
How can we clear this alert ?
In fact the fact the system LED is Amber is not a good sign from the customer perspective. As well as when we let it stay in the Amber LED state we wouldn't that a bigger problem (and a true one) may happen ?
The CIMC version is : 1.5.4f
Please advise.
Thank you for your input Keny.
In fact we don't have a second PSU since it isn't shipped with the server. So, in our case (BE6K server) it's clearly a false alarm.
Is there a way to acknowledge/delete/ignore the alert, so that we don't get confused with other more important alerts that may truly affect the platform ?
Thank you again.
Similar Messages
-
PSU_REDUNDANCY - Redundancy Lost
Hello all,
I'm experiencing this issue on my UCS-210 :
on the Power Status in my VMWare it display :
Power Supply 0 PSU_REDUNDANCY - Redundancy Lost ==> this give message Warning
Power Supply 2 PSU2_STATUS: Power Supply AClost - Deassert ==> This give message Normal
Power Supply 1 PSU1_STATUS: Power Supply AClost - Deassert ==> This give message Normal
Can anybody explain this message "PSU_REDUNDANCY - Redundancy Lost ".
Has anybody already experienced this issue?
What can I do?
Regards,
AntraHello,
Thanks for the reply.
I'm just planning to do it. But we have to wait.
I'll give updates. :-)
Cases that can be happen :
1/ The PSU doesn't works in other UCS : The PSU is faulty?
2/ The PSU works in the other UCS, while the permuted doesn't work in the old UCS. Where is the issue?
3/ The PSU works in the other UCS and the permuted PSU work also in the old UCS. Energy issue? Card issue?
4/ Shut down the UCS. Unplug the Power cable/ Wait for 30 min/ Start the UCS: Everything gone well or Not. (this mode works sometimes when there are voltage differential issue and the ground issue )
Regards,
Antra -
Windows server 2012 R2 compatibility with UCS C220 M3S
Hello,
Anyone knows if i can install Windows server 2012 R2 in UCS C220 M3s ?
Best regards,
Pedro SérvoloCiao Pedro
Please use this utility:
http://www.cisco.com/web/techdoc/ucs/interoperability/matrix/matrix.html
I don't know you talk about standalone, UCS managed, which version,....... -
Managing the UCS C220 M3S with the UCS Manager
I have 2 new Cisco UCS C220 M3S running 2.0(3b) and 2.0(1b) connected to a UCS-FI6248UP 5.2(3)N2(2.23d) via a Intel X520-DA2. I also have both management interfaces up via a 100 meg copper connections. My issue is that I can't see these servers in the UCS Manager the UCS-B was a no brainer but the C's are not discovered, I've looked through both the CIMC and the UCS Manager and I don't see an option to change the management to the UCS Manager. I'm sure that I'm missing something since this is my first experience with the UCS C or UCS as a whole. Thanks
Hi,
Please make sure that the Set up of the UCS C-Series Server Integration with UCSM is correct. Here is the guide when you will be Configuring Single-connect to the IO Module FEXs.
You can also review the link here : Managing Rack-Mount Server.
Let me know if it helps,
Abhishek -
UCS C220 M3S with PCI mezzanine card raid SAS 2008M-8i :((
Hello
May be someone has already spend a little time with this configuration. the main stuff is my ucsc doesn't think he has disk to boot one even if with CIMC I see the opposite.
I configure with server conf utility ucs-cxx-scu-3.1.3b.iso with raid1 and as I have 2 UCS C220M3S I do also with Raid0 on another one. the trick is when I install ESXI 5.1 (VMware-VMvisor-Installer-5.1.0-799733.x86_64.iso) during install the setup od VMware detect the disk and install on it but after reboot always same storie no disk !!!
I don't see where to do something ??? So If someone encountered this problem, my be has already find the trick
The bios is C220M3.1.4b.0 and I have also a PCI Broadcom 5709 1Gbps 4 port NIC on slot 2 on both UCSC
here is the config 2xXeon CPU E5-2650 @2.00Ghz with 64 GB of Ram.
Any idea is welcome
Cheers
CX
and for the one configure with raid1UCS C220 M3S with PCI mezzanine card raid SAS 2008M-8i
file attach UCSC220M3S right setup.pdf give illustrated answer
Point was VM distribution but bios which does not see SAS PCI Mezzanine Ctrl
Thanks to PDI help -
Cisco UCS C220 M3S Server OS random shutdowns
Hello good day, I am facing some issues with the Cisco UCS indicated in the subject, I have created a Raid 1 beetwen 2 HDD's of 1 TB each one, also upgraded the firmware of the UCS with the 2.0(3f) HUU tools, and upgraded everything. Then I installed Windows Server 2012 R2 Eval version (I have a proper license to install but wanted to test the OS first). Now some times the OS/Server just shutsdown, and whenever I go in to the Web GUI to check it out, it's actually powered down, I have checked the "Faults and Logs" --> System Event Logs, and I can see this happening:
*The timestamp is from below to the top on both logs*
MAIN_POWER_PRS: Presence sensor, Device Removed / Device Absent was asserted
Microsoft OEM event data record, Record type: DD, Sensor Number: 0A, Event Data: 00 00 00, Raw SEL: 37 01 00 35 0A 00 00 00 00
(About this message with the HEX Values, it's always repeating it self with other values)
System Software event: OS Stop sensor, OS Graceful Shutdown was asserted
In the IMC Log this is what showed when it powered down:
Bridge.c:1484:audit Resp:0x0
Bridge.c:1478:audit from:kcs Fn:0x0 Cmd:0x6 Data: 0x30 0x4
obj/../../src/BiosSecureBootAgent.cc:101:BiosSecureBootAgent --> m_valid_state = [ 0 ] #012 m_enable_state = [ 0 ] #012 m_setupMode_state = [ 1 ] #012 m_secureBoot_state = [ 0 ]
obj/../../src/BiosSecureBootAgent.cc:63:get=uefiSecureBootState Received
bootordermgnt.cpp:2392:WriteBIOSDeviceCfg: Successfully renamed file: /mnt/jffs2/ConfigPolicy.xml.bak to /mnt/jffs2/ConfigPolicy.xml
bootordermgnt.cpp:1310:StoreDeviceCfg: Successfully renamed file: /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT.bak to /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT
bootordermgnt.cpp:2392:WriteBIOSDeviceCfg: Successfully renamed file: /mnt/jffs2/ConfigPolicy.xml.bak to /mnt/jffs2/ConfigPolicy.xml
bootordermgnt.cpp:1310:StoreDeviceCfg: Successfully renamed file: /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT.bak to /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT
bootordermgnt.cpp:2392:WriteBIOSDeviceCfg: Successfully renamed file: /mnt/jffs2/ConfigPolicy.xml.bak to /mnt/jffs2/ConfigPolicy.xml
bootordermgnt.cpp:1310:StoreDeviceCfg: Successfully renamed file: /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT.bak to /mnt/jffs2/avct_ems_cfg/BMC_Data/BOOTDEV.DAT
bootordermgnt.cpp:1367:No Precision Boot DB exists..migrate old relase configuration to Precision Boot format!
sanluis1/platform.c:116:platform_event_enable_tick_end: Configuring IR from CIMC
(A bunch of these with other values) common.c:945:Enabling sensor scan for sensor 0x85.
lv_dimm.c:403:[handle_event_enable_tick]enable sensor event
lv_dimm.c:220:[transition_function]Transition to [High Voltage Mode] Success
lv_dimm.c:200:[transition_function]Starting Transition to [High Voltage Mode] from [Unknown Mode]
(A lot of these with different values) common.c:940:Disabling Sensor scan for sensor 0x89.
lv_dimm.c:129:[lpc_reset_seen]LPC Reset Count is Different [0x15:0x16] Asserted LPC Reset Seen
selparser.c:678: # 1D 03 00 00 01 02 00 00 DB F7 EF 54 20 00 04 25 05 00 00 00 08 00 FF FF # 31d | 02/27/2015 04:51:39 | CIMC | Entity presence MAIN_POWER_PRS #0x05 | Device Absent | Asserted
Received event_ipmi_power_state_change Event (type=4, size=0)
video_trigger.c:262:Sending event_ipmi_power_state_change (OFF) .
WatchdogTimer.c:1467:Current Configuration of Watchdog timer is now stopped.
Pilot2SrvPower.c:466:Blade Power Changed To: [ OFF ]
<5>[se_pilot2_wakeup_interrupt]:2561:USB HS: VDD Power = OFF
<6>drivers/bmc/usb/usb1.1/se_pilot2_udc_usb1_1.c:2540:USB 1.1 is now disconnected.
<5>drivers/bmc/usb/usb1.1/se_pilot2_udc_usb1_1.c:2288:USB FS: VDD Power WAKEUP- Power Good = OFF
<7>[slp_state_isr]:117:Signals SLP3n[ Asserted ] SLP5n[ Asserted ]
<6>[platform_power_state_irq_handler]:18:VDD_PWR_GOOD: Deasserted
In the event viewer of the Windows Server 2012
This is the UCS specifications:
CPU 1: Intel(R) Xeon(R) CPU E5-2609 v2 @ 2.50GHz
CPU2: Intel(R) Xeon(R) CPU E5-2609 v2 @ 2.50GHz
Memory: 16 GB
There is something really itching, is it because I have Evaluation version of the Windows Server...?
Regards.Ok, I feel kind of dumb now, I have checked the tech evaluation page on Microsoft, and if it's not connected to the internet it will not inherit the three months evaluation trial, which I thought would come activated already, and only allows you up to 10 days grace period with the rearm command .... :/
The process C:\Windows\system32\wlms\wlms.exe (WIN-UDPFG5O0K37) has initiated the shutdown of computer WIN-UDPFG5O0K37 on behalf of user NT AUTHORITY\SYSTEM for the following reason: Other (Planned)
Reason Code: 0x80000000
Shutdown Type: shutdown
Comment: The license period for this installation of Windows has expired. The operating system is shutting down.
This is what made me check it out today, I will connect it to the internet and let it activate... Meanwhile the command for the 10 days grace is:
Slmgr /rearm
Shutdown –r
Like always. -
Problem with the new server UCS C220 for set IP to CIMC
Hi
We’ve a problem with the new server UCS C220.
We bought two servers UCS C220 M3 for CallManager 8.6 with High Availability.
When we turn on the server during the boot and when it tells us, oppress F8 to enter at the CIMC and set the IP. But it never enters at the CIMC.
Then, we configure our DHCP server and our switch, we connect the three gigabyte ports to our switch to give him an IP to the CIMC, so and then can enter via browser, but neither works.
Note. The dedicated management NIC does not link, the other two ports do make link.
What do you suggest to put an IP to CIMC and start installing our applications?
regardsYou may have noticed that there is no DVD rom on the c220. What you need to do is:
Login into the CIMC from your browser
Luanch the KVM
Insert the VMware DVD in your machines drive
On the KVM pop up there should be a tab to mount the drive, after mounting it click on Macros and choose ctrl_alt+delete to restart.
After the VMware OS installs press F2 to enter IP.
Browse to the VMware ip to download the Vsphere client
Open the Vsphere client, enter the ip of the vmware and the username will be root and no password if you did not set one.
You can now upload OVA templates or manually create virtua machine from this enviroment.
Hope this help -
Hi Experts,
Good Day!
I have a new UCS C220 M3L server which I will be using for my CSM however, when I tried to install my OS (Windows Server 2008 R2 - 64 bit) I don't see the disks, it says that no drivers where found - please see attached file.
May I know where can I download that drivers also what is the recommended version of the drivers that needs to be downloaded?
Thank you very much for the great help.
Cheers,
niksHi Walter,
Thanks for the response.
I'm not able to check the BIOS but I can confirm that the RAID is detectable. It shows during the boot up process of the UCS it is currently in RAID 5.
Do you have an idea on what driver version should I download for my UCS?
Thank you and have a nice day!
niks -
Migrating User from MCS 7828 H3 to UCS C220
Hi All
I wanted to can someone tell me what is the process for migrating users from a MCS 7828 to a UCS C220. A associate of mine called me about doing a migration from the MCS to the UCS series and he wants to know how does he get the users over to the new platform.Thanks in advance for the help and have a great day.Hi Scooter817,
There are a few options depending on what the customer has today and what will be the end state. Below are the most common scenarios:
1st Scenario - Customer is on older SW releases (8.x, 7.x, etc..) on MCS server(s) without UCSS wanting to move to new SW releases (9.x) on UCS C220. The most cost effective way is to buy $9 upgrade per user per application SKUs (ex. UPG-6K-ENH) with UCSS for 3 years. There is more information on the BE6K product page under the partner section around migrations BE6K Product Page - http://www.cisco.com/go/be6000
2nd Scenario - Customer is on older SW releases (8.x, 7.x, etc..) on MCS server(s) with UCSS wanting to move to new SW releases (9.x) on UCS C220. Since they have UCSS, they can go to PUT with thier contract number request updated SW and licensing, then re-host licenses to the new server. PUT link: http://tools.cisco.com/gct/Upgrade/jsp/productUpgrade.jsp
3rd Scenario - Customer is on older SW releases (8.x) on MCS server(s) with or without UCSS wanting to move to same SW releases (8.x) on UCS C220. They can re-host licensing to the new server via SWIFT. Here is the link to the process. https://tools.cisco.com/SWIFT/LicensingUI/lookupLicenseForRehost
Thanks
Blake -
Redundancy Interface for Content Server Release 6.x
Third-generation Content Server is UCS C220 (Not Vmware).
I see from TCS Release 6.x Quick Start which cannot use LAN2.
I'm not sure. How to connect LAN for redundancy interface or not because it have many NIC card.
Dual 1-Gb Ethernet ports:
LAN1 (Arrow 7, left pointer)— Use this port to connect the Content Server to the network (also see Figure 3)
LAN2 (Arrow 7, right pointer)— Not usedHi,
The TCS server supports only single NIC in a deployment. That particular NIC value is used to generate the checksum, which needs to be passed along with the Release keys to bring up the content engine. That is the reason if you connect any other NIC to the network, the content engine will not start.
Also, when the release keys are generated on the license server, it uses the NIC with the lowest value (always the first NIC on the server).
I know its a complete waste to have so many NICs and use only one. But what can I say, thats the way Cisco designed the server..!!!
Regards,
-Deepti -
Cisco UCS C220-M3 Server doesn't boot after adding Intel I350 Quad Port NIC
Hello,
We have purchased 2 Cisco UCS C220-M3 rack mounted servers (Single Processor) that have a dual port I350 LOM. We also purchased two Intel I350 Quad Port NICs to expand the available ports on each server from 2 to 6.
The problem we are facing is that the server will not complete the boot process unless we disable either the LOM or the Quad Port NIC. We have tried numerous settings in the BIOS area but we haven't managed to have them both working.
The I350 Quad Port NICs are from Intel and not from Cisco and we are running the latest FW/BIOS on the Servers as of March 10 2015.
We have followed the steps described in the installation guide to install them.
Could you provide some light in this situation please, what are our options?
P.S. Although the LOMs are I350, the MAC Address Vendor is Cisco, is it possible that Cisco servers accept only Cisco Branded Expansion Cards?
Thank you,
GeorgeHi Shawn,
At least I'm not the only one having the same problem!
You are trying to use the cards with the LOMs enabled?
Which screen are you referring to in the first paragraph of your message?
Mine sits in BIOS POST for about 10 minutes and then resets itself....
We are also waiting for an answer from Cisco, so any findings/news will be posted here.
Thanks,
George -
UCS C220 not recognizing LSI 9266 MegaRaid card
I just received a new UCS c220 with a seperate LSI 9266 MegaRaid card. I have installed the card adn connected the SAS cables and BBU. When I start the server it doesn't recogize the card. If go into CIMC the card is not listed. I have changed the SAS cables and resetted them all several times. I have resetted the card several times. I have not changed any of the settings yet so I may be missing something there that will make it recongize the card but I have followed all available instructions as well. Any thoughts on what I could be missing?
Yes I have it installed in PCIe2 per the instructions. It won't fit in PCIe1 anyway . I have also looked up the LSI card specs to make sure I have the cables correctly attached. See attached images for configuration in BIOS as Robert suggests and evidence of cabling and PCI location.
Thanks for the assist. -
Unable to find ctrl+H message in UCS C220 Server
Hi,
I am unable find Ctrl +H message at the time of booting to get enter in Webbios.
Please help me.
Hardware: UCS RAID SAS 2008M-8i
Rgds,
SambhabWhat firmware are you running on this server?
Did you buy this raid controller direclty from cisco or from a partner.
Based on the screenshot you provided the firmware on your controller looks very old, I recommend that you use the HUU to upgrade the firmware of the adapter to the same level as your server. Use link below to download the firmware package for your server.
Cisco UCS C220 M3 Rack Server Software
http://software.cisco.com/download/release.html?mdfid=284296253&flowid=31742&softwareid=283850974&release=1.5%283d%29&relind=AVAILABLE&rellifecycle=&reltype=latest
Example Video of firmware upgrade.
http://www.youtube.com/watch?v=qRahHRja15M -
Hello!
I am trying to use a UCS C220 M3L that we just purchased as a host for Virtual Machines. Here are the hardware specs of the server:
UCSC-C220-M3L
UCS C220 M3 LFF w/o CPU mem HDD PCIe PSU w/ rail kit
UCSC-PSU-650W
650W power supply for C-series rack servers
UCS-CPU-E5-2665
2.40 GHz E5-2665/115W 8C/20MB Cache/DDR3 1600MHz
UCS-MR-1X162RY-A
16GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v
UCS-HDD500GI1F211
500GB SATA 7.2K RPM 3.5 inch HDD/hot plug/drive sled mounted
CAB-9K12A-NA
Power Cord 125VAC 13A NEMA 5-15 Plug North America
UCSC-PCIE-CSC-02
Cisco VIC 1225 Dual Port 10Gb SFP+ CNA
UCSC-BBLKD-L
3.5-inch HDD Blanking Panel
UCSC-HS-C220M3
Heat Sink for UCS C220 M3 Rack Server
UCSC-PCIF-01H
Half height PCIe filler for UCS
UCSC-RAIL1
Rail Kit for C220 C22 C24 rack servers
SFP-10G-SR=
10GBASE-SR SFP Module
I had orignally thought of using Ubuntu 12.0.4 LTS as the OS and KVM for virtualization. As I read through the supplied docs and attempt to do just that I have some concerns. First is the Embedded RAID controller. According the quick start guide:
"VMware ESX/ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller. Hypervisors such as Hyper-V, Xen, or KVM are also not supported for use with the embedded MegaRAID controller. "
I went into BIOS and checked the settings for the Embedded RAID controller and saw that there were two options: MegaRAID and Intel RSTe. I could not find any thing in the documentation about the difference between these two settings and what would happen if I selected one over the other. I tried both controllers with the two installed drives as a RAID 1 pair and as non-RAID disks with the same results.
The second issue I ran into was that the Ubuntu installer did not recognize either of these two controllers and failed to install. Based on the published documentation, I saw that RHEL 6.4 was supported, so I downloaded and installed CENTOS 6.4 . The installer did detect the Intel RSTe controller as a "Firmware RAID" and installed what I believe is OS level RAID configuration. I say that because when I check the Intel RSTe bios, is still shows two non-raid disks.
So with this background, I am re-grouping to see what is the best way to proceed and have the following questions:
1) Will I be able to run a virtualized environment at all with my current hardware config?
2) What is the difference between the embedded RAID options: MegaRAID and Intel RSTe?
3) Can I just ran both my drives as bare drives without any RAID? Will that deal with the virtualization issue of not being supported with the embedded MegaRAID controller?
4) Do I have to order hardware RAID controller?
5) I have read about the Flexi-Flash disks having the ability to slip-stream Linux drivers during the install but no procedures on how to do that. Where can I find them?
6) Has anyone had any luck installing Ubuntu with this hardware configuration? Is it supported? Or should I just press on with CENTOS?
7) Related to CENTOS, I installed the basic server option and added GNOME desktop with X-Windows to get some GUI Admin tools. When I trying using startx to initiate a session, it appears that the X-Windows server attempts to start, the screen goes black into Graphical mode and drops back to the CLI with a message that server terminated successfully. Anyone know what is going on here?
Sorry for the long message and I appreciate any help that you can provide!
Thanks!
DaveHello David,
If you're going to load ESXi on these servers, there are a few things you need to consider when ordering them. For instance, you cannot boot from ESXi using a software RAID controller. So, even if you have some local/internal hard drives and even if you can install the ESXi OS on those hard drives, you will not be able to boot from them if you have the software RAID controller. "VMware ESX/ESXi or any other virtualized environments are not supported for use with the embedded MegaRAID controller. Hypervisors such as Hyper-V, Xen, or KVM are also not supported for use with the embedded MegaRAID controller" (source: Cisco USC C220 Server Installation and Service Guide). If you're going to use a SAN and you don't even need the internal hard drives, I recommend using what Cisco calls the Flexible Flash Card. This card is basically an SD card that comes pre-configured with four virtual drives. The first drive is the Cisco UCS Server Configuration Utility, the second is the HV or Hypervisor, the third contains the Cisco Drivers, and the fourth is the Cisco Host Upgrade Utility. The HV drive is where you can install your ESXi server and can be made bootable from within the CIMC. This is much easier than worrying about which kind of RAID controller to get, and I believe it is a little less expensive than getting local drives with a hardware RAID controller.
Here is a high level overview of the steps to follow from racking to booting ESXi.
To configure the CIMC:
Install the Flexible Flash Card in the server.
Rack the UCS server and plug a network cable into the management port.
Power it on.
Press F8 to configure the CIMC information (IP address, password, etc.).
From a computer on the same network, open a browser and connect to the CIMC using the IP address assigned in step 3.
Go to Servers | Inventor | Storage to see the Flex Flash Storage Adapters.
Click Configure Operational Profile and then put a check next to the virtual drives you'd like to enable (i.e., the HV drive).
To install ESXi:
Click Launch The KVM from the CIMC.
In the KVM window, click Virtual Media.
Click Add and browse to where you've downloaded your Cisco Custom ESXi .iso file and then put a checkmark next to it so it's mapped as the Virtual CD/DVD.
Click back to the Monitor tab and then click Macros. Select the Ctrl-Alt-Del macro to reboot the server.
Press F6 as the server is rebooting to change the boot device to the Virtual CD/DVD.
Install ESXi as you normally would, but make sure to install it to the HV drive (not to the local drives).
When the install is complete, unmap the Virtual CD/DVD and reboot the server using the macro again.
Press F6 to change the boot device to the HV drive, and it should now boot to the familiar yellow and gray ESXi screen.
Regards,
Shahzad -
Continuous Beep sound on UCS c220
Hi Guys,
We just got a new UCS c220 server, we were deploying Esxi on it and all of a sudden it started alarming a beep sound and it is continuous, there are no logs generated either CIMC nor the led indications, what might be the possible reason, an inputs would be helpful, thnx in advance
Regards
KrishnaUdupi,
As Dan stated, it might be an issue with your RAID. In the past, I have experienced similar beeping when there was an issue with the RAID group. Except for the LSI controller, I'm not aware of any other componentt that would continuously beep on the server during operation
http://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/raid/configuration/guide/MegaRAID.html#wp1105151
Table 5-3 gives a translation between the beep intervals and potential issues.
If you can reboot and interogate the LSI OptionROM during POST, you may find what it is complaining about
Table 5-3 Summary of LSI MegaRAID Card Beep Codes
Beep Code
LSI Firmware State
Cause (Depending on RAID Level)
3 seconds on, 1 second off
SPEAKER_OFFLINE_ENTRY
•RAID 0: One or more drives offline.
•RAID 1: Two drives offline.
•RAID 5: Two or more drives offline.
•RAID 6: More than two drives offline.
1 second on, 1 second off
SPEAKER_DEGRADED_ENTRY
•RAID 1: A mirrored drive failed.
•RAID 5: One drive failed.
•RAID 6: One or two drives failed.
1 second on, 3 seconds off
SPEAKER_HOTSPARE_ENTRY
A hot spare drive has completed the rebuild process and has been brought into the array.
Maybe you are looking for
-
I have a replacement iphone 5 but the serial number is not working
Hi i have a iPhone which has been replaced. I can not seem to check my warranty status as my serial number is not being recognised i need help.
-
Company wide Custom Outlook Events - Exchaneg 2010 sp3
Is there a way to create a company wide related recurring event/holiday in Outlook at the exchange level which shows up in all the employees Outlook???? rather then manually doing it on each user mentiond here http://office.microsoft.com/en-ca/outloo
-
Ship to party error whils entering sales order
Hi, After putting sales area (1234/14/00) for order type OR on main screen VA01, received an error on the overview screen as Ship tp party AB1234 in not defined for sales area 1234/14/01 though we have already maintained common division for condition
-
hi Im getting the following error when querying a database : <b> Error when executing statement for table/stored proc. 'procedure name' (structure 'Select'): java.sql.SQLException: [Microsoft][SQLServer 2000 Driver for JDBC][SQLServer]EXECUTE p
-
Hi, Friends, Can anybody suggest me where i can find JMS scenarios? i need to implement JMS adapter at my client site. i would like to familiarize myself with JMS scenarios. Thanks and Regards, Venky Bhat