Manual or Tutorial of LabWindows/CVI?

Hi everybdy, i'd like to know, if anybody knows some manual, tutorial or
how getting started , in the program LabWindows/CVI 5 or other version, in
Internet . Thanks for your attention,and sorry for my English.

"laxus1" wrote:
>Hi everybdy, i'd like to know, if anybody knows some manual, tutorial or>how
getting started , in the program LabWindows/CVI 5 or other version, in>Internet
. Thanks for your attention,and sorry for my English.>>
Hi
The book is ""LabWindows/CVI Programming for Beginners""
Have a look on the following web site.
Type LabWindows on book search.
http://www.phptr.com/
Also try Amazon.com at
http://www.amazon.com/exec/obidos/ASIN/0130165123/o/qid=975622255/sr=8-1/ref=aps_sr_b_1_3/107-7675244-9336531
You can also try EBAY if you like to bid on book.
http://cgi.ebay.com/aw-cgi/eBayISAPI.dll?ViewItem&item=510511275
Hope that help.
Rejean Lafortune
CAE Electronics Ltd.
Avionics Interface Engineering

Similar Messages

  • Manual or Tutorial of Labwindows/CVI 5?

    Hi everybdy, i'd like to know, if anybody knows some manual, tutorial or
    how getting started , in the program LabWindows/CVI 5 or other version, in
    Internet . Thanks for your attention, and sorry for my English.

    Here's a web site that should help:
    http://zone.ni.com/devzone/devzone.nsf/webproducts/a77c886190b47fd286256785006d6ca9
    I got here from ni.com/support, selecting Measurement Studio for the first pulldown and clicking on "LabWindows/CVI: Tutorials and Examples" at the top of the page.
    Good luck,
    Brad

  • Manual or Tutorial of Labwindows

    Hi everybdy, i'd like to know, if anybody knows some manual, tutorial or
    how getting started , in the program
    LabWindows/CVI 5 or other version, in Internet . Thanks for your attention,
    and sorry for my English.

    Wow! Don't apologize for English that's better then most peoples who claim to speak English. For instance peoples is terrible English.
    Anyway, I don't have a great answer but if you have not found any help yet let me know. I think the best way to learn CVI is to just dive in a when you get stuck phone a lifeline. In other words try and get a network going with other CVI users. Email me with some basic CVI questions and I might be able to help.
    Grant
    Grant M. Johnson
    Project Engineer
    LECO Corporation

  • Documentation on How to Develop an OPC Client Using LabWindows/CVI?

    What documentation is there on how to develop an OPC client application using LabWindows/CVI?  What tutorials, if any, are there?  What reference manuals, if any are there?
    I am completely new to LabWindows/CVI.  I will be starting soon with the tutorial, "Getting Started with LabWindows/CVI".  However, our application needs to communicate with an RSLinx OPC Server.  Any documentaiton on how to learn to do this would be very much appreciated.

    http://www.ni.com/white-paper/4626/en/  Just did a quick google and this came up, Labwindows CVI and Labview are quite different but I usually look at Labview examples then try take the general idea from the example and apply it in CVI, hope this helps

  • Are there any exams for LabWindows​/CVI for my assessment​?

    Hi
    I'm new in CVI
    I'm still studying its features
    Can anyone give me a link where I can learn more about CVI, a tutorial perhaps.
    I'm really interested about data manipulation and databases.
    What database can I use with CVI?
    And
    Are there any exams I can take for the assessment of my knowledge about CVI?

    Hi Kylie may,
    On our website there are many helps for you to learn LabWindows/CVI.
    1) Here is a link to the Getting Started manual
    2) Additional Resources
    3) Top 10 LabWindows/CVI Technical Resources
    4) If you are interested in Database connectivity please take a look at the following link to the SQL Tool kit
    5) As far as Exams that you can take here is a link to the information: NI Certified LabWindows™/CVI Developer (CCVID)
    I hope that this helps.
    Regards,
    Perry S.
    Applications Engineer
    National Instruments

  • Drive VXI-MIO-64E-1 in LabWindows/CVI

    I'm integrating a VXI system based NI's VXI-1394 controller in which VXI-MIO-64E-1
    was used. My develop envirenment is LabWindows/CVI 5.01. When I use the MIO
    card to sample a waveform, the only length of the waveform I can sample is
    2048Sa. Then, I insert 2 SIMM with size of 8MB to the MIO card, but it is
    useless.
    How can I configure and use the onboard Mem of VXI-MIO-64E-1? Could you give
    a sample program in CVI?
    Thank you very much!

    Hello Vishnu,
    Unfortunately, the VXI-DAQ cards are no longer supported, but you can find information about using them in the manual.  The VXI-MIO Series User Manual  has details about setting the input range in Chapter 3 on page 3-4.
    Good luck with your application!
    Meghan
    Applications Engineer

  • Need to install LabWindows​/CVI PID Control Toolkit (Part Number 320794A-01​)

    Hello -
    I have a customer with a very old application who needs to upgrade their system to Win7 64-bit. The app references the old PID functions (manual here: http://www.ni.com/pdf/manuals/320794a.pdf) but no matter what I have searched for, I cannot find an installation for that toolkit. I have never had a need to use the current PID toolkit so I am not versed with it, and the difference in the functions do not seem to be a 1 to 1 change. Additionally, the customer is not paying for a code change - just assistance with the upgrade and reinstall. I would greatly appreciate if someone could point me to that download. 
    If such a download is not in existence any longer, I will need to request some assistance with modifying the source to use the current PID functions. I could attach the pertinent code if need be (there are not a great deal of references).
    Thank you.

    Hi CVIBri,
    The installation files for the LabWindows/CVI PID Control Toolkit 2.1 are located at the URL below.  I realize these are only officially compatible with versions of Windows up to Vista, however this is the most recent version of the toolkit that exists.  I've also provided a link to the Evaluation License Files.  That being said, LabWindows/CVI 2013 SP2 now includes the PID Control Toolkit as part of its Base and Full versions, and it is fully licensed with the same serial number used to activate the LabWindows/CVI development environement. The Readme linked below should provide more information.
    PID Control Toolkit: http://www.ni.com/download/labwindowscvi-pid-contr​ol-toolset-2.1/1037/en/
    PID Control Tookit Evaluation License Files: http://www.ni.com/download/labwindowscvi-pid-contr​ol-toolset-2.1/1038/en/
    LabWindows/CVI 2013 SP2 Readme: http://www.ni.com/pdf/manuals/374674a.html
    Thanks,
    Myriam

  • Acquisition de température (Labwindows/CVI, NI9211)

    Bonjour,
    Je débute sur Labwindows/CVI, je suis entrain de concevoir un petit système de supervision. J’essaie dans un premier temps  de faire juste l’acquisition de température grâce un module NI 9211 et l’affichée sur une interface graphique de Labwindows/CVI. J’ai installé le DAQ mx mais je ne sais pas comment faire pour intégrer la mesure à mon programme. Si quelqu’un peux me dire comment faire ou me renvoyer sur un tutoriel cela m’aiderai beaucoup.
    Je vous remercie d’avance. 

    Hello there,
    The following tutorial might be of use to you: www.ni.com/white-paper/2931/en/
    Please let us know if you have any trouble with it!
    Thanks,
    Daniel D.
    National Instruments
    Automated Test Software R&D

  • VXI-MIO-64E-1 in LabWindows/CVI

    I am using VXI-MIO-64E-1 module for Data Acquisition of differential Signal of 0-10V. By default Module is configured in -5V to +5V. I have used  status = AI_Configure (deviceNumber, chan, inputMode, inputRange, polarity, driveAIS) function for configure module to 0-10V unipoler but  still module is taking -5V to +5V not 0-10V.  here is LabWindows/CVI code for configuration of analog input module.
        buffer = (short *)malloc ( NUMPOINTS * sizeof(short));
       status = Init_DA_Brds (1, &brd);
       if ( status != 0 )
        MessagePopup("Error","Error in initializing VXI device");
        exit(-1);
       status = SCAN_Setup (1, NUMMODULES, ChannelList, ChannelGain);
       if ( status != 0 )
        MessagePopup("Error","Error in configuring VXI device");
        exit(-1);
       status = DAQ_DB_Config (1, 1);
       status = DAQ_Config (1, 1, 0);
       status = Select_Signal (1, ND_PFI_7, ND_IN_SCAN_IN_PROG, ND_LOW_TO_HIGH);
       if ( status != 0 )
        MessagePopup("Error","Error in Configuring SCAN_START input Line");
        exit(-1);
       InitializeTimer1();
       /* Module 1 Initialization Over */
       /* Module 2 Initialization Starts */
       buffer1 = (short *)malloc ( NUMPOINTS1 * sizeof(short));
       status = Init_DA_Brds (2, &brd);
       if ( status != 0 )
        MessagePopup("Error","Error in initializing VXI device");
        exit(-1);
       status = SCAN_Setup (2, NUMMODULES1, ChannelList, ChannelGain);
       if ( status != 0 )
        MessagePopup("Error","Error in configuring VXI device 2");
        exit(-1);
       status = DAQ_DB_Config (2, 1);
       status = DAQ_Config (2, 1, 0);
       status = AI_Configure (2, -1, 0, 10, 1, 0);
       /* Module 2 Initialization Over */
    What mistake i am doing to configure module-2 to 0-10 Volt input range.

    Hello Vishnu,
    Unfortunately, the VXI-DAQ cards are no longer supported, but you can find information about using them in the manual.  The VXI-MIO Series User Manual  has details about setting the input range in Chapter 3 on page 3-4.
    Good luck with your application!
    Meghan
    Applications Engineer

  • Test NI cDAQ-9188 using LabWindows/CVI

    I am looking for help to create test for cDAQ-9188 with DIO and AIO modules.
    Would you please advise with information as follow:
    1. Adding device driver to a project.
    2. Sample of UI.
    3. Sample of test script for DO (AO) control.
    4. Sample of test script for DI (AI) acquisition.
    Thank you.
    Sincerely,
    Sam.
    [email protected]  

    There is a tutorial on using DAQmx with LabWindows/CVI here: http://zone.ni.com/devzone/cda/tut/p/id/2931. That is probably a good place to start.
    Another good article to check out is the NI Ethernet Data Acquisition Overview here: http://zone.ni.com/devzone/cda/tut/p/id/7374.
    As far as examples go, there are several text-based examples (as long as you have DAQmx installed) located at: Start Menu >> All Programs >> National Instruments >> NI-DAQ >> Text-based Code Support >> ANSI C Examples. 
    National Instruments

  • Getting tarted with LabWindows​/CVI realtime

    Hello everyone, i'm getting started with LabWindows/CVI and it's realtime module. I've got a NI PCI-6221 and i want to use it to generate some signals. I want to know how to communicate the host (control) part of my software and the targetRT part. Please advice me some example or tutorial which describes howto do that. 

    There are several examples available in the example finder under Toolkits and Modules » Real-Time which should demonstrate what you are looking for.
    Communication between the host and target is usually done using network published shared variables, the whitepaper below discusses this:
    http://www.ni.com/white-paper/4679/en#toc1
    You can find an example of this usage here:
    https://decibel.ni.com/content/docs/DOC-3806
    Are these resources what you are looking for?
    Craig H. | CLA | Systems Engineer | National Instruments

  • Labwindows/CVI and Android

    Hello,
    I work in Labwindows/CVI on Windows XP for the moment, I developpe a software and I would like to know if it will be possible to make a software, the same that this one to run on Windows, which runs on Android please ?
    My software uses a SQL database (SQL Server) and an OPC Server (Phoenix Contact).
    If it's possible, how can I do to create this application and install on a tablet for example?
    I just know that a "NI LabWindows™/CVI Run-Time Module for Linux" exists, but I don't know if this module allows me to install my software on a tablet...
    Thanks.
    Bye Karine

    In addition Android programs are normally written in Java, which has nothing
    to do with CVI. But I read a tutorial some time ago that showed how to
    compile C for Android. So at a very basic level of a pure ANSI C program
    with no (or duplicate) user interface, it is possible.
    Guillaume Dargaud
    http://www.gdargaud.net/

  • Visual Studio or LabWindows/CVI?

    I have a bit of a dilemma.
    I currently own Visual Studio 2010, IMAQ Vision Development Module 2013, and Measurement Studio (not sure of version). I currently do all of my programming in VB.net. Because IMAQ VDM is stuck in .Net framework 3.5 and there will be no further .net development by NI, I need to plan for the future. My applications need run on Win 8, 9, 43, or whatever my company decides to migrate to from Win 7.
    My understanding is that the NI modules I currently own will work with LabWindows/CVI. Correct? I also believe I can use them with C++ using the VS IDE. Is this also correct?
    Within my applications I do a lot of interfacing with Excel, writing text files, and interfacing to non-NI devices (cameras, DAQs, scanners, etc). I am able to do these things pretty easily using VB.net using vendor-provided SDK's.
    Therefore, my question is this...given the investment I have in software already, do I gain anything by migrating to LabWindows/CVI? What do I lose?
    I should point out that regardless of the path I choose I will need to bone up on my programming skills in the corresponding language.
    Thanks for all your help!

    Hello Steverino!
    Here are some advantages when using LabWindows/CVI over Visual Studio, which make the product more suitable for various industry-related applications:
    You are correct, LabWindows/CVI integrates with the NI platform: NI hardware and software, like TestStand or LabVIEW (e.g. debugging source code from one software to another, seamlessly).
    NI hardware and third-party hardware connectivity.
    OpenMP support.
    CVI integrates with intrument control.
    CVI Run-Time benefits from User Protection.
    Run-Time checking (e.g. for uninitialized variables).
    Scientific User Interface Controls and GUI Editor.
    Advanced debugging capabilities:
    Remote debugging support from ADE.
    Real-Time debugging support from ADE.
    Memory leak detection using the LabWindows/CVI Resource Tracking Window.
    Just-In-Time debugging.
    Deployment: build custom installers and patches that you can ship as stand-alone easy-to-use installers.
    LabWindows/CVI libraries: Advanced Analysis, Toolbox, Connectivity (Network Variables, Network Streams, DataSocket), etc.
    Support for LabWindows/CVI Toolkits: SQL Toolkit, Vision, PID, RT.
    Regards,
    - Johannes.

  • Software Development Engineer positions at Hysitron, Inc. in Minneapolis (LabWindows CVI exp preferred)

    Software Development Engineer
    Hysitron, Inc. is a premier scientific instrument manufacturer. Founded in 1992 with headquarters located in Eden Prairie, MN we are committed to promoting nanotechnology by developing advanced transducer and control technology. This leadership has made Hysitron the world leader in nanomechanical test instruments. The TriboIndenter®, TriboScope®, Ubi, and other Hysitron innovations have opened new horizons for scientists interested in investigating and understanding mechanical properties of materials at nano-scale. Hysitron fosters an environment and culture where innovation flourishes, teamwork is encouraged, and superior performance is rewarded.
    Hysitron invites applications for multiple software development engineer positions from those aspiring to explore and succeed in the nano world. Hysitron, Inc. is an Equal Opportunity Employer M/F/D/V
    Job responsibilities
    The software development engineers would be responsible for developing test and measurement software applications for nano-mechanical testing instrumentation. Job deliverables would include:
    -          Develop software applications in C based Labwindows CVI for Hysitron Instrumentation
    -          Support the development of applications to address challenges in instrument automation and control
    -          Test software applications using debugging and simulation tools
    -          Perform software releases and software quality assurance activities
    -          Participate in the design of new software products
    -          Perform maintenance activities for existing products
    -          Adapt and deliver on quality software development practices
    Minimum qualifications
    -          BS in Computer Science/ Computer Engineering/ Equivalent Scientific or engineering discipline
    -          Min of 3 yrs experience in Instrumentation software development in an industrial or R&D environment
    -          Expert at programming language C, knowledge of C++
    -          Working knowledge of various communication protocols, e.g. USB, RS232, IEEE, RS485, TCP/IP, Modbus
    -          Knowledge of general software design/documentation processes in test and measurement systems
    -          Proficient problem solving skills
    -          Strong analytical and technical skills
    -          Excellent communication and interpersonal skills
    Preferred Qualifications
    -          Proficient with LabWindows CVI and XML
    -          Working experience with DSP(Code Composer Studio) and/or FPGA level programming
    -          Exposure to digital electronics and instrumentation
    -          Working experience in Robotics interface programming
    -          Experience with Controls/Automation engineering
    Application and Information
    Qualified candidates should send a letter of application and their resumes to (please include ‘SW Engineer’ in subject line):
    Hysitron, Inc.
    10025 Valley View Rd
    Eden Prairie, MN 55344 USA
    Phone: (952) 835-6366
    Fax: (952) 835-6166
    E-MAIL: [email protected]
    Web: www.hysitron.com

    This position is still accepting resumes/CVs.

  • How do I send e-mail to a distribution list using LabWindows/CVI?

    I need to be able to send e-mail to a user-defined distribution list using LabWindows/CVI? Has anyone done this? Any ideas where I could look?

    I commented on something similar to this awhile back.  My issue was that I had the base version and didn't have the Internet classes.  So this external app worked like a charm
    It has a lot of command-line inputer options to use as well.
    http://forums.ni.com/t5/LabWindows-CVI/Need-Help-for-Sending-Email-with-LabWindows-8-5-or-9/m-p/1095...

Maybe you are looking for