Manually added Values in the info-object

Hi there,
I have manually added 1 value in the info-object.
But if I view in the P table I am not able to find it.
But I am able to find this value in the SID table.
When I do my dropdown in the query selection screen, it does not show me this value what I manually created and when I just enter this value it gives me error as invalid value.
Please advise.
Many Thanks,
Kate

Hi AHP,
I have done both of them.
But still the same result ? Any further suggestion ?
kind regards
Kate

Similar Messages

  • How to dispay the text values of the info objects in my transformations

    Hi
    Can any one say how to do a lookup for a text table. For example for a particular customer number i need to get the customer name from the text table.In the same way i need to display the text values of the info objects in my transformations. It would be great if any one could send me the code.
    Thanks
    R

    Thanks for the immediate reply Anshul, Actually i am having the fields of short description and long description in my text table,  my requirement is to display only the long description data in the text table. So it would be great if you could get me the solution.
    Thanks
    R

  • How to enter values for an Info-object Manually.

    Hi
    I have to enter certan values manually in the customised info-object which are not available in the
    BW at the moment.
    If I go via SE11 I am only getting change option.
    If I go via SM30 it says The maintenance dialog for ****** is incomplete or not defined.
    How can I enter certain values to this info-object.
    Please advise.
    Many thanks,
    Kate.

    Hi
    Use transaction rsdmd to maintain infoobject values - or right click any infoobject an select maintain master data.
    Regards,
    Beat

  • Error when assigning SID while uploading text in the info-object of the DSO

    Hi
    I have a scenario where I need to extract a char 60 field from R/3 in the DSO.
    I have created the info-object which is char 60 which has the master data text activated.
    In the DSO transformation I have mapped it to the R/3 field.
    While activating the data in DSO its giving the error message
    'Value '20 per action plan' (hex. '32302070657220616374696F6E20706C616E') of characteristic'
    'Error when assigning SID: Action VAL_SID_CONVERT InfoObject ZRMSD '
    How to overcome this issue.
    Please advise.
    Thanks in advance.

    Change the InfoObject for this text so that it will allow lowercase letters. To do this, go into Change mode on the InfoObject, go to the General tab, check the Lowercase letters checkbox and activate the InfoObject. After this has been activated, you can then restart your process and this SID violation error should no longer be thrown for this.
    If you don't want to do this, then you can use the TOUPPER formula in the Characteristic Routine, in the Transformation, to change the value of this field contents to uppercase. This can also be done by using an ABAP routine like this:
    TRANSLATE column TO UPPER CASE.
    Edited by: Dennis Scoville on Nov 3, 2009 9:55 AM

  • Error while activating the info object.

    Hi,
    While activating one of the info objects, i am getting the following error message:
    Characteristic 0BP_GRP: Cannot switch off InfoProvider property
    Message no. R7B289
    Diagnosis
    The characteristic receives master data from other objects (for example, transformations or update rules). Therefore it is necessary to select the characteristic as an InfoProvider.
    Procedure
    If you want to deselect the Characteristic Is InfoProvider indicator, delete the corresponding objects in the data flow.
    Thanks and Regards
    Niren.

    Hi Niren,
    Check the below thread..
    Howto Remove 0Employee Char from my InfoArea
    Hope it helps..
    Regards,
    Ramki.

  • How to activate the Info object catalog in Business content

    Hi,
      While trying to activate the Info object catalog, I found that some of the info objects under this catalog was earlier activated by some other developer. I brought this catalog (0SALES_CHA01) over to the Business content activation panel ( with only 'necessary object settings ) and all the info objects that also came along  were de-selected since I didn't want to install those again). When I tried to install these I get an error indicating that some of the info object in question are not already active.. and ultimately the catalog doesn’t get activated , although more than half of its infoobjects are already active under the '0CHANOTASSIGNED' node.
    Please let me know whether I can get only the Catalog activated without getting any existing activated info object merged or installing those which are not already activated.
    Thanks
    Arunava

    Hello Arunava,
    Just drag the infoobject catalog as u did earlier to the left in the bus cont installation screen with "only necessary object" option.
    Dont try to deselect any object. Go ahead with the default options and install in background.
    Now you can check for the available objects in the catalog. if you have some objects missing, and available in unassigned node,double click on the newly installed infoobject catalog, select the required objects (which are not yet assigned to this) from the left side and bring them to the right side.
    this will make the unassigned objects assigned to the required catalog.
    Hope it helps..
    (please dont forget to reward points to helpful answers)

  • Error in Transport the info object

    Dear all,
    i am trying to transport  the info object 0CM_CTAR
    during transpot i am getting the error as
    Characteristic 0CM_CTAR: Unit 0UNIT_DIM no allowed in compounding
    but i checked in development i  not got any error but when i am trasport iam getting error.
    Regards,
    siva.

    HEllo,
    Please see these OSS Notes
    1139547 - Transport of InfoObjects RC = 8
    1100575 - InfoObjects: Using units in compounding
    The other way is to use a Z* object referenced to needed unit object  in the compouding,
    Regards,
    Shashank

  • How to track the user who deleted the info object.

    Dear Gurus,
    In our BI system one info object has got deleted.  If I need to track the user who has deleted that how can I track it(in which DBtable).  And the complication is one user ID is being used by many people, in this case how can I track that from which machine the Info Object has been deleted(if there is any possibility to track the machines by IP address).
    Kindly let me know if there is any procedure to find it out. Your help will be rewarded with a great honour.
    Regards
    Mohan Kumar

    Hi dear,
    you have to go in SLG1 transaction, and then select
    Object: RSD
    Subobject: IOBJ_DEL
    External ID: (put here the name of your deleted IO)
    Then choose a time range...and voilà, you can find the user who deleted the IO...
    Hope it helps!
    Bye,
    Roberto
    About the IP...look at USR41 table, but I think it's a bit difficult fo find data referred to the past...
    If you haven't activated logon auditing in SM19...

  • How to increase the length of the Info object

    Hi All
         Any one have idea about how to increse the length of the Info object Char(beyond 60). Can you please explain me in detail we are using BI7.0.
    Thanks
    Vani

    Hello Vani,
    You cannot increase the length of an info-object beyond 60 chars.However if you want to store a characteristics data with more than length 60, then you may create separate info-objects
    for example: if you need to store 'notes' which might have length more  than 60,
    then you may create info-objects like notes 1/3 ---store first 60 chars.
    notes 2/3 --- store next 60 characters and so on.
    Thanx
    Priyanka

  • How to remove the space in the info object level?

    Hi,
    I created a Master Data info Object and gave the data type as <b>Char</b> and length as <b>30</b>.
    From the source system I am getting the data of length 9. But at PSA level I am getting some erroneous records.
    Example: Data from the source system  'a12345678'
                   Data in PSA 'a12345678b'     -
    ***  where b  - Blank
    With out changing the length how can I remove the spaces (Blank)?
    Can any one suggest me how to remove, where and what to apply ?
    I need to do any settings at the info object level or at the Transfer Rule?
    Please provide the each and every step to resolve my problem.
    Thank you

    Hey  you can allow space in RSKC tcode and execute it... .that's it .
    and below is the routine for invalid chars and you can have this in update rules ..
    data: w_fielda(x) type c.
    data: w_result(x) type c.
    data: w_temp_field(1) type c.
    data: w_count type i.
    w_fielda = COMM_STRUCTURE-/BIC/Zxxxxxx.
    w_count = 0.
    do x times.
    clear w_temp_field.
    w_temp_field = w_fielda+w_count(1).
    if w_temp_field CA
    '!"%&''()*+,-./:;<=>? _0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ'.
    w_result+w_count(1) = w_temp_field.
    endif.
    w_count = w_count + 1.
    enddo.

  • How to reduce the length of the info object that's being used?

    Hi All,
    I have created info objects and used them in a DSO. Now I want to reduce the length of the info objects but i'm unable to do it. When I reduced the length and tried activating the Info object, it's giving me error and the info object is not getting activated. Please guide me how I can reduce the length and activate the Info Object.
    Thanks
    Hima Bindu

    Reducing the length of an infoobject is not that easy
    Cleanest way -
    Drop all transaction data for that infoobject
    Drop all data in the DSO and cubes.
    Reduce the length and then activate and transport all the infoobject and there dependence objects.

  • How can we find out the info object in a query ....?

    How can we find out the info object in a query is belongs to that particular info cube? If the query is built on a Multiprovider having 4 different info cubes.

    Hi,
    If you have restrictions at the infoprovider level in the RKF then it is coming from that particular infocube.
    Or go to the selection option in the multiprovider...her you can get the mappings of which key figure is populted from which infocube.
    For characteristics you will have to look for identification tab in the characteristics option.
    Thanks

  • How to put a value into the Gauge object

    Hi Experts
    I would like to use the DS_1.getData() command to retrieve data from a query
    and place it into a gauge (standard object in DS). What I understand is that
    the getData command retrieves a float value and the gauge object expects an integer
    value. I didn’t find a float to integer conversion so I tried a work around. It
    looked something like this but it did not work:
    GAUGE_1.setValue(Convert.stringToInt(Convert.floatToString(DS_1.getData("CKXYNLFBDHH0X2U91711DX83S",
    {"ZQMSITEPD":'S999'}).value)));
    The value from the float to string conversion holds the decimals like 49,937 and this creates an error in the conversion from
    string to int.
    Does anyone have an example on how to get data from a DS into a gauge?
    Kind regards
    Erik

    HI Erik, have you tried to use the Convert object?
    float can be converted to string with argument "###", this will round all numbers after colon.
    eg.
    var fullNumber = Convert.floatToString(55.83, "###");
    var numberInt = Convert.stringToInt(fullNumber);
    APPLICATION.createInfoMessage("Value " + numberInt);
    fullNumber = Convert.floatToString(55.23, "###");
    numberInt = Convert.stringToInt(fullNumber);
    APPLICATION.createInfoMessage("Value " + numberInt);
    see for many examples
    Design Studio 1.3 Scripting Example to Convert String Number to Date
    Regards, Karol

  • To switch on the Navigational attribute feature in the info object

    Hi there,
    I have a sceanario where I created an info-object to extract the KNKK table information.
    I am using the datasource 0fi_ar_9 to do flexible update to this info-object.
    The issue is that: I am adding the required infoobects as attributes to this infoobject.
    I want to switch on these attributes as  navigational attributes.
    But to some of them I am getting the option to switch it on as Nav and not all. Like 0C_CTR_AREA has got the icon Navigational attr on/off. Also 0CRED_GROUP has got this icon across it.
    But objects like
    0LST_INT_RV -Last Internal Review
    0LST_REVIEW -Last Review (external)
    0REPR_GROUP -Credit management representatives group
    0NXT_REVIEW-Next Review
    do not have the Navigational attribute on/off icon across them.  So I am unable to change them to Nav.
    Any advise why is the behaviour different for different objects ?
    Thanks in advance.
    Kind Regards,
    Kate

    Hi There,
    Many thanks for the answer.
    It really solved my doubt about this.
    This means that I need to create customised info objects
    to add them as navigational attributes.
    Just wanted to know what is the advantage of creating infoobjects as reference charateristics of standard infoobjects.
    Thanks once again.
    Kind Regards,
    Message was edited by: Kate Smith

  • Adding navigational attribute in Info Object.

    My staging layer is as below.
    Data source1-> DSO1
    Data source2-> DSO1
    Data Source 3->DSO1
    From DSO1 : there are 3 Transformaitons.
    DSO -> Info Object “ABC”
    DSO1- > DSO2.
    DSO1 -> DSO3.
    That means. DSO1 , is supplying data to ABC info object and 2 more DSO's.
    I need to Enhance Data Source 1, with Field “X”  add it in DSO and then add that field in Navigational attribute of IO “ABC.
    I dont need this field “X” in DSO2 and DSO3.
    Question :
    1) I want to understand its effect on Transformations if I add field in DSO1.
    Data source2-> DSO1
    Data Source 3->DSO1.
    DSO1- > DSO2.
    DSO1 -> DSO3.
    2) Will all these be inactive ( assuming yes, )
         a. Do I need to retransport all the transformations.
         b.And if Yes, I assume we need to transport DTP’s too.
    3) Does adding of navigational attribute affect any other Cubes and DSO  or transformations ,containing the main Info Objects. "ABC"..
    Note:  This new navigational attribute is not used in any of the old cubes. it wil be used in new design.

    hI,
    1. If add any field to DSO1, then incoming and outgoing transformations will go inactive.
    2. a. Yes.
        b. Yes.
    3. No, but info ABC object transformations may go inactive.
    Thanks

Maybe you are looking for

  • Ios6 updation query

    I am using 4s, after updating ios6 ,the language in apple stores has changed

  • How to map a deep xml structure to flat structure

    Hi, I'm trying to map a deep xml structure to a flat file structure. See this: <SalesPoint>          <header>               <idTx></idTx>               <opCode></opCode>          </header>          <body>           <DataSet>                <codOperac

  • Keyboard replacement.??

    Got a used s9 4067 off ebay.  2 keys missing.  I just decided to replaced the keyboard.  Hopefully I'll win the bid on ebay. Any how if I do I need to replace the whole keyboard and not just the keys.  Can't find any info on google, etc. Anyone know

  • Reader 8 omits lines/borders when printing docs

    I'm using Acrobat Reader 8.1.3 with Vista.  When I select PRINT, all the lines and borders are present in the preview/composite pane of the print window, but they are not present when the page prints out.  All other alpha-numeric characters are there

  • I cant connect my MBP to the apple tv. HELP

    hi guys i'm using a mountain lion MBP and just got a new apple tv . tried following some instruction from youtube and found that the option in display pefernece for mirroring to apple tv is not there. isnt the mirror option available on the mountain