"MATERIAL-ADDITIONAL DATA-UNIT OF MEASURE"

There is a Business Content for "MATERIAL-ADDITIONAL DATA-UNIT OF MEASURE" tab page?
Thanks
Serena

can you plz tell more detail.
Regards
Bhima

Similar Messages

  • Production Order for a Material with two units of measure?

    Hi Everybody I have the following issue.
    In my company there is a new production process with a Material that should be configured in the master data with the field "Base Unit of Measure" as per unit (each). But the production process, should be confirmed by tx CO11N, in Kilograms. I know that I can use the additional Data in tx MM03 to set a Production Unit, but the value of convertion would be fixed. For example 122 Kg = 1 each, the thing is that the value in kilograms for each lot can vary, one lot can weight 122 and another one can weghr 125, and in each case I shoul have two units in stock. And as I have the value of convertion fixed, when I confirm each lot one for 122 kg and another for 125 kg I will have 2.025 units in MB52.
    How can I solve this problems? I need to have the chance the confirm in kg changing for each lote the quantity but in the base Unit of Measure have one unit for lot. As if for tx CO11N I could have a field where I can set tha x quantity of Kilograms is x each.
    Kind regards
    Leandro. 

    Hi Ayoub, First thank`s for your promt answer,
    1. The Quantity is different, because is not a perfect process, there is a manual work in the process that makes this quantity differ, there is no big difference, maybe a Kilo or Two but the production mannager wants to have this registered. And besides in productions they manage kilograms, but for selling the comercials manage units (each - EA)
    2.The convertion rate is known at the end of the process after cutting and packaging a unit, they weight it.
    Regards
    Leandro

  • Material master-additonal unit of measurement

    HI, I have three questions
    a) we have the follwoing data defined in material master (additonal data)
    X UOM Y UOM EAN
    1 LITRES 1 LITRES NIL
    1 IGB (inner packg) 20 LITRES 345922222222
    1 GBE (packg) 20 LITRES 345922222222
    I need to know what is EAN no and in our case the EAN no is same for both inner packg and pack. . what does this mean. Sometimes we also see the EAN no is different. why... what it signifies ?
    2) We have outbound idoc trigerred from delivery. message type is WHSOD. in one of the segments (E1EDL24), the system shows the delivery qty and material no. This segment also shows the EAN NO AS 345922222222. In segment E1EDL26, the filed UMVKZ shows as 1 which is ok (numerator as shown above) but the numerator field shows 1 only (it does not show 20 litres,, i think the field name is UB something ).
    I need to know why the system is not showing 20 litres in numerator in the filed for segment E1EDL26.
    3) Had we have two different EAN in material master as above, did our standard message type would have shown the conversion factors (numerator and denomi ) as per the EAN nos.....If yes, then in which segments ,the WHSORD shows the Conversion factors based on different EAN nos in material master-UOM tab (for instance if 1 GBE (packg) = 30 LITRES and EAN IS 345911111111.... I think there will be as many segments in idoc as there are entries in Additonal data-UOM tab )
    rgds
    pamela

    Hi Jurgen,
    I think you did not understand. My questions is as follows.
    a) why we maintain alternative UOM in material  mastr (additional data) ? an example ould be good.
    b) We have in our system base unit of masuement as  litres and sales unit as blank. that means system will take sales unit of measurementt as litres only.
    now we make sales order and make delivery and a outbound whsord idoc is sent to third party warehouse. the third party warehouse undertsands only IGB(pack ) unit of measure wherase our idoc i think will carry LT (litres ) as UOM...
    we do maintain the conversion factor between litres and IGB in our material master (additional data tab).That is our idoc shud carry conevrsion factor as maintained in ur material maste ( 20litres =1 igb ). so our idoc shud carry .05 as conversion factor
    so that our third party warehouse understands that and dispatch 1 IGB of qty (2 litres as per our delivery )
    rgds
    Pamela
    Edited by: Pamela79 on Aug 11, 2011 4:49 AM

  • MB51 Material Document List Unit of Measure

    Can/How is this list displayed with the unit of measure converted to one unit?
    Example Material movements for liquid with units in gallons and pounds.
    Want to list all in pounds.
    Conversion is entered in material unit of measure tables.

    you can see this in MMBE but not MB51 because this is the material document list and which will shows the Gr unit ( you can display the base unit but not conversion)
    convesion can only be displayed in MMBE

  • Change Material Number and unit of measure

    Can we change material code and / or its Unit of measure . Please help

    http://sap-img.com/materials/change-base-unit-of-measure.htm
    Re: change material code
    Change of unit of measure

  • Material to Material ( diff. Unit of Measure )

    Dear Gurus,
    I have a material that undergoes a repacking and come out in diffrent unit of measures, i have to do a transfer of the existing material to the new materia which will have a new unit of measure.
    In transferposting it is possible only if both the material have the same stockkeeping unit.
    Please advice how to go about it.
    Best Regards,
    Sat

    Hi,
    There is another thread asking the same question.
    Unfortunately the answer is the same.
    You cannot use a 309 movement if the base UOM is different.
    You can use two other movement to replicate this (write off one material and write ON the other) the financial postings should balance out correctly but you need to decide which movement types you want to use (different GLs will be updated depending on if you want to write them off and on, or consume one material and "reverse consume" the other with a 201 and 202 scenario)
    Steve B

  • Addition: New Units of Measurement

    Dear All,
    I think, its MM-related query. However, I am sharing it with all you people.
    I need to add new Units of Measurements, like RIM, which are not configured in Standard SAP-Sysem.
    Where do i congigure the same (Path & T. Code)?
    Also, what are other significant pre-requirements for configuring new Units of Measurements?
    Thanks and Best Regrds,
    Amit Kr. Yadav

    hi,
    use t codE: CUNI ---> click dimensions
    else
    spro> img>general settings-->check unit of measures
    hope this helps u
    regards,
    Arun prasad

  • Additional/suplimentary unit of measure for Intrastat

    Hi!
    I am trying to generate the Intrastat declaration.
    I have a problem; i am using an commodity code with suplimentary unit of measure p/st. But I cannot define the unit of measure p/st in SAP because the maximum lenght for unit of measure is three characters.
    There should be a table BNADDM in SAP where suplimentary unit of measure exists. But this table in empty im my system.
    How can I configure unit of measure p/st in SAP in order to add it to commodity code configuration?
    Thanks,
    Marcel

    found in Romania_Intrastat_docuE.doc which is attached to OSS note 1016386 - Intrastat for Romania
    Customizing for the Electronic format
    Please note following customizing related to the conversion of the Supplementary Unit of Measure has been involved.
    The issue: The information about unit measure in SAP is maintained with majuscule (capital letters) and in external system (INS) no (e.g. M3 in SAP and in INS it is m3.)
    The customizing is to setup the correct INS supplementary units of measure. Once you need to convert any UoM supplied with SAP application, fill the external system (INS) Unit of measure via the maintenance view:
    /CEECV/ROLO_UO_V via transaction sm30.

  • Material upload: alternate unit of measure problem

    Hello,
    I'm uploading materials using LSMW (BAPI nethod: BUS1001006). I have a problem for the records with alternate units of measure. I put the units in a separate file and map the ISO code and the Numerator. However, I receive an error M3333 for the materials with 2 rows (one basic UoM and other alternate), which says that I have to maintain conversion factors for the alternate UoM. I thought, I'm doing so by providing Numerator (E1BP_MARM-NUMERATOR), but somehow it's not enough.
    Any assistance will be highly appreciated
    Thanks in advance,
    Eli

    Wrong definition in MARMX structure.

  • Need Multiple Units of Measure for a given material due to multiple vendors

    Hello,
    We have a requirement where we must have multiple units of measue (each, box, case, pallet) for a given material.
    Background:
    We have multiple vendors for one SAP material number. We need to store 4 levels of units of measure for each vendor+material combination.
    Unit of Meaure levels
    1. Each
    2. Innerpack (ex: 12 each = 1 innerpack)
    3. Box (ex: 36 eaches = 1 box)
    4. Pallet (ex: 100 eaches = 1 pallet)
    Standard SAP allows in MM01 additional data --> Units of Measure only 1 Ea, Box, Plt, etc.
    Our requirement is to allow multiple Units of Measure due to multiple vendors providing the same material.
    So, our unique combination is by a Material+Vendor.
    We are considering adding the vendor name and vendor number to the material master --> additional data --> Units of Measure tab.
    Does this seem like a good solution? What impacts do you foresee with approach?
    Any alternatve solutions?
    We thought we could enhance the purchasing info records to allow multiple units of measure too but then we need to also add many fields to hold the weight, lenght, height, width, volume, country of origin, etc.
    Please recommend a best practice or solution to handle this requirement.
    Thanks in advance!!!

    Hi,
    Maintain the alternative units in Material Master in Additional Data -> Units of Measure section with proper conversion factors.
    Create individual info-records i.e. per mtl-vendor combination & in the info-record maintain the order unit, along with other details as required.
    Now when you create a PO, the details will be read from the info-record. To test the same, create them in your sandbox & see if it meets your requirement.
    Hope the above clarifies your query.
    Regards,
    Vivek

  • Mass deletion of Batch specific unit of measure

    Dear Experts,
    How to delete the batch specific unit of measure in the material master maintained in the additional data -unit of measure and proportional / production unit of measure in mass . We have some 1000 material for which we want to remove the datas related to batch specific unit of measure from the material master.

    I have not yet seen an option to delete data with MM17, but I am open to be educated.
    I would suggest you do it with LSMW or CATT.
    However, test it first in MM02, before you waste your time with mass processing. You might receive errors if that material was already in use and batches exist.

  • Confirmation unit of Measure

    Dear All,
    Please guide me is it possible that order unit of measure is To but confirmation unit of measure is PC. is yes then how

    dear friend,
    first, if you run MM03 for your materils and have a look at "Additional Data" -> "Units of measure" you will probably see the units 'TO' and 'PC'.
    second, if you run , say CO11N to enter the time ticket for that material,  you will be able to set the unit of measure which you saw at material master :
    Set the Yield (quantity) and Conformation unit of measure (which the yield/scrap is confirmed).
    Save the confirmation.
    Done.
    good luck!

  • BOM Unit of measure.

    Hi gurús,
                 I want to include a material in a material list with a different unit of measure than the base unit of measure recorded in the material info record.
    I tried creating a new unit measure in the additional data at the material info record, but then, when I include the material with the new unit of measure in the material list, the system display an error message (A) as the following:
    "Unit of measure KG not supported for material XXA in plant AAB"
    I would like to know how to include a material in a material list with a different unit of measure.
    Example:
    Material 100
    Base unit of measure: UN
    CS02
    Additional data --> Unit of measure: KG
    CS02 --> Material 100 with unit KG.
    The system display error message (A).
    Thanks in advance
    Regards
    Enzo

    Hi gurús,
    I want to include a material in a material list with a different unit of measure than the base unit of measure recorded in the material master record.
    I tried creating a new unit measure in the additional data at the material master record, but then, when I include the material with the new unit of measure in the material list, the system display an error message (A) as the following:
    "Unit of measure KG not supported for material XXA in plant AAB"
    I would like to know how to include a material in a material list with a different unit of measure than the one in the material master record (base unit of measure)
    I hope to have been more clear
    Regards
    Enzo

  • Table for alternative unit of measure

    HI
    I have created a material whose Basic UOM is Kg
    I have maintained alternative unit of measure as TON and maintained the relationship 1 ton = 1000 Kg in material master -- additional data -
    units of measure.
    I want to capture the data for creation of report ....In which table this data is stored ?
    Thanks
    Sara

    MARM

  • Maintaining Unit of Measure (not alternative)

    Dear colleagues,
    I need to maintain a unit of measure (1 BOT is equal to 45 DEG) where we are going to use it for Z programsu2019 calculations, not in standard functions.  But I don't want to maintain this ratio under additional data  units of measure because if I maintain then there is possibility of being use this new measure in sales ordersu2019 etc. Is there any other field where I can maintain this ratio without infecting standard calculations?
    Regards

    I would suggest you need to put logic in Zprogram.When ever program finds this UOM it will automatically converts and will update in sheet.
    Maintain UOM convertion in  a Z table.This will help if you want to add some more UOM  it is use ful to you.While running in Z report it will fetch the convertion from table .

Maybe you are looking for