Material master saving error

Hi Friends,
In the general plant data/Storage I am trying to change the profit center but I am gettting error message that Program terminated while deleting old export control data (update).Message no. M3668
What Can I do to avoid this error.
Thanks,
Kiran

Hi,
You need to understand your business solution and better refer your project documents for your designed solution.
As Ztable designed , may be profit center designed with enhancement for plants( one profit center for one plant where during material creation of material ,profit center defaulted automatically) - you need to understand logic before changing profit center in material.
Regards,
Biju K

Similar Messages

  • Close period for material Master record error

    my current period is 07 2010.
    I want to close period 07 2010, and make new posting to period 08 2010.
    but when i do the posting, system show error "Posting only possible in periods 2010/07 and 2010/06 in company code C999"
    PS: C999 is the company code that contains the plant P999
    And when i try to close the current period of material Master record  by MMPV, system show below information :
    "L O G
    Mode: Check and close period
    Client: 000
    Period entered (month/year): 07 2010
    Incorrect period in control rec. of CoCd C999; no conversion The current period (month/year) of the control record is 07 2010
    Period closing complete; log issued.
    E N D"
    and my current OB52 setting is below:
    Please help to supply some suggestion.
    P999     +               1     2010     12     2010     13     2010     16     2010
    P999     A          ZZZZZZZZZZ     1     2010     12     2010     13     2010     16     2010
    P999     D          ZZZZZZZZZZ     1     2010     12     2010     13     2010     16     2010
    P999     K          ZZZZZZZZZZ     1     2010     12     2010     13     2010     16     2010
    P999     M          ZZZZZZZZZZ     1     2000     12     2010     13     2000     16     2010
    P999     S          ZZZZZZZZZZ     1     2010     12     2010     13     2010     16     2010
    V001     +               1     2000     12     2010     13     2000     16     2010

    Hi,
    Check in T.code: MMRV and see which period is open for ur Co.Code and back posting is allowed or not. If you are sure to open new period now of  new posting to period 08, then
    use t.code: MMPV ,
    enter
    Company code C999
    Period to open 08
    Fiscal Year 2010
    Execute
    ( system will close the period last period 07 and automatically system open the new one 08)
    Now try ur transaction.
    if any problem, then check  in FI Side:
    Use t.code: OB52 and open the 08,2010 period in Account Types A, K, D,M, S and specially Account Type u201C+u201D which stands for valid for all accounts type and save. Better consult FICO consultant for OB52 step.
    Regards,
    Biju K

  • Create material master get error message

    Hello Guys,
    I get the error message as below when i create material master .  can you help me? 
    error message
    nternal error in FORM/FUNCTION ckms_buffer_write in position 19 with RC 0
    Message no. C+099
    Procedure
    Please inform your system administrator.
    Thanks and best regards,
    Alengao

    Debug the program with help of ABAPer and check it.
    Also pls check these NOTES,
    414204, 933809, 390655,0001096890
    0001126497
    0001164684
    0001230454
    Edited by: Afshad Irani on Aug 12, 2010 3:12 PM

  • MM03 - Material Master Consumption Error

    Hi,
    We are now moving into the ECC 6.0 version from 4.6C version. During testing in the upgrade test system of ECC 6.0 environment, we identified a particular issue.
    In the material master change / display if we select BASIC DATA 1 view and enter into the ADDITIONAL DATA and then select the Consumption TAB system is deflecting back to the basic data 1 screen with an error message "Fiscal year variant is not maintained for the calendar year 2003".
    We are able to edit / view the consumption details for the materials (being used since 2001) in our 4.6C system.
    When the Technical team tried to trace the difference between the 4.6C and the upgraded ECC env test system, they were able to identify an additional coding that checks the fiscal year variant and periods assigned to the fiscal years.
    The code simply checks the current period and fiscal year and if it is less than the number of periods, it will continue to the previous period and so on.
    Now we have an issue where we had periods defined upto 13 for the fiscal years 2001, 2002 and 2003 (during that time the fiscal variant used to be week based year and now it is period based year dependent variant from 2004 with only 12 periods.
    Hence the system is checking the period number and if it is less than or equal to the total number of periods 12, it will continue into the consumption tab, or otherwise it will pop the error "FISCAL YEAR VARIANT IS NOT MAINTAINED FOR THE CALENDAR YEAR 2003".
    Please advice if anyone else had got into a similar situation involving this issue
    Thanks
    Alluri Venkat

    HI Anand,
    I am going to assume that the problem is with F4 help in general, and not just with MM03.
    If you have only one user with the problem, then the best way to troubleshoot is to compare with another user who is not having the same problem (like yourself).
    First check Help settings for the user:  From any screen, select Help>Settings  select F4 tab.  Review the settings. Look for differences.  Make corrections.  Save.
    If you can find nothing amiss, then the GUI is probably the culprit.  Check to see if this user is on the same version and patch as the 'successful' users.  From SAPLOGON, select the tiny SAP icon from the blue bar, then select 'About SAP logon'.  Alternately, you can right clik on the SAPLOGON on the Windows taskbar and select 'About SAP Logon'. 
    There are known problems of bad interactions between certain Microsoft Software and certain patches of SAPGUI.  If any problems, download the latest GUI version and patch from SAP software distribution Center
    http://service.sap.com/swdc
    Select Download>Support packages and Patches>Entry by Application group
    Select SAP frontend components.
    Select the appropriate platform, then download the version that you need.
    If the user is on the same vers & patch as you, and you can't find any other problem, might be a good idea to reinstall the SAPGUI.
    Regards,
    DB49

  • Material master creation error through LSMW

    Hi,
    I have a problem with creation material master through LSMW with object type BAPI.  I use below import methods
    Business Object BUS1001006 
    Method                SAVEDATA
    Message Type    MATMAS_BAPI
    Basic Type          MATMAS_BAPI03
    Material number is configured length of 12 with leading zeros.
    In my text file material number is given as XXXXXXXXXXX which is 11 digits. When I start IDoc processing it issues an error message u201CMG019 the numeric material number & was transferred without leading zerosu201D.
    Then I add 0 to material number in the file (it becomes 0XXXXXXXXXXX) and run IDOC processing it issues same error message again.  
    How I can resolve this issue?
    Thanks

    Hi,
    Please check the below link...
    Re: Creating new material using i/b MATMAS IDOC
    and also check the OSS note 707602.
    Hope it may help you.
    Kuber
    Edited by: kuberk on Aug 14, 2011 4:00 AM

  • LSMW - inforecord / material master - syntax error when converting data

    Hi all,
    I used LSMW for classification uploads (material master, vendor master) so far - it was easy :-). But..I tried to create/update inforecords by object 0060, method 0000, program RM06IBI0. I declared source structure, source fields, field mappings and conversion rules (in my batch input I use only fields which we defined as required for infrecs.), files etc. LSMW reads the data but when I try Convert data - the is syntax error in program /1CADMC/SAP_LSMW_CONV_00000018 and dump with message "For type "C", a maximum length specification of 65535 is allowed." When I tried to create material master (object 0020, method 0000), Convert data command worked the same.
    Any help would be appreciated. (? sample from your batch input file which works well to compare)
    Tomas

    Hi Tomas,
    Please do me a favor. In the initial screen of LSMW, there is a pushbutton for 'Personal Menu'. Once you press that it will pop-up a screen with a bunch of checkboxes. Select the checkbox for 'Display Conversion Program' and press enter. Now you should see the 'Display Conversion Program' option in your initial screen. Select that and go into the conversion program. Put a break-point in the conversion program on the statement 'perform execute_data_conversion.'.
    Debug it and find out exactly where the error is occuring. Perhaps that will help you figure out what the error is, if not, let the forum know where you hit the error. Even looking at the dump, you should get more information.
    Srinivas

  • MG144 Error  Messages while creating Material Master

    Hi,
    When creating Material Master getting Error for structure field is required. Message Number MG144.
    Pls suggest.
    Regards,
    VR

    Go through this note 45998
    Or check, which field is required field and try to maintain or just make the optional entry in customizing

  • Dump Error In Material Master Transaction

    Dear Experts,
    When i am creating or changing any material master record, i am getting the below dump error while saving the material.
    What happened?
        Error in the ABAP Application Program
        The current ABAP program "SAPLC1F2" had to be terminated because it has
        come across a statement that unfortunately cannot be executed.
        The following syntax error occurred in program "SAPLC1AX " in include "%_CESPCL
         " in
        line 77:
        "Component called ATWRT already exists. ."
        The include has been created and last changed by:
        Created by: "SAP "
        Last changed by: "SAP "
        Error in the ABAP Application Program
        The current ABAP program "SAPLC1F2" had to be terminated because it has
        come across a statement that unfortunately cannot be executed.
    Error analysis
        The following syntax error was found in the program SAPLC1AX :
        "Component called ATWRT already exists. ."
    Trigger Location of Runtime Error
        Program                                 SAPLC1F2
        Include                                 LC1F2U10
        Row                                     594
        Module type                             (FUNCTION)
        Module Name                             C1F2_SUBSTANCES_SAVE_TO_DB
    Can you please help me out with this?
    Thanks,
    Praveen

    Hi,
    I have not made any changes in the Enhancements/BADIS which are related to ATWRT, but created one ZTable for linking the
    Vendor (LIFNR), Material (MATNR) & Manufacturer (ATWRT).
    Here are the additional details of the dump which i am getting in MM01/MM02 transactions for your reference.
    Moderator message - Please respect the 5,000 character maximum when posting. Post only the relevant portions of the dump
    Can you please help me with this?
    Thanks,
    Praveen
    Edited by: Rob Burbank on Feb 2, 2011 9:29 AM

  • I have uploaded Material Master thr LSMW but Materials are not saved.

    Hi
    i have uploaded  Material Master through LSMW but unfortunetly Matreials are not saved in system.

    Hi
    Check first with one record you are able to create the material Manually by using tcode MM01.
    Or Rerun the batch Input in Foreground mode so that you can see the error or whether Materila no is created
    I do not think so any test mode in Batch Input session.
    Check the Log in SM35 for your session if you have any error messages.
    Hope it helps
    Karthik

  • Error while changing the UoM in material master

    Hi experts....
    I am not able change the UoM in the material master. Even if,  all the PR , PO and reservations are cancelled .
    It still gives me error message " Manual  Reservations already  exists "
    Thanx
    Ganesh

    Hi
    may be some entries got not cancelled properly and entries got locked.
    Just check in SM12 if no entries are locked.
    regards
    Sidi

  • Error while creating a material master (mm01)

    hi,
    I'm getting this error message when I'm creating a material master in a specific plant/sloc. I'm probably guessing its in config. I really need some help here.
    "Tables TCURM and T001W inconsistent; notify your system administrator" .
    could any one  draw some light on this.
    thanks regards,
    chinta

    HI,
    Before creation of plant 1st check in t.code:OMSA and see your plant assigned to field reference.
    Check in t.code: OMSY, see your company code entry & active for material management.
    Also check your plant is active for your material type in t.code: OMS2 with quantity & value updating.
    ###Check assignment of plant to company code in t.code: OX18 and see activation of your valuation are in t.code: OX14
    Just cross check all material master customisation , refer link with t.codes:
    Re: Material Master
    Regards,
    Biju K

  • Error Message no. MM214 while creating material master

    Hi folks!!
    While creating material master, when i fill the MRP controller field and press enter, I get the message...
    The MRP controller 391 does not exist for plant
    Message no. MM214
    I have checked, the MRP controller is availble in Master Data for MRP Controller. And we have already created many material master with this MRP Controller.
    What could be the possible cause for this error. Please help.
    Best regards

    Hi Qamar,
    Please go thru the bellow threads,
    Assignement of MRP controller to Plant
    MRP CONTROLLER
    MRP Controller
    Re: MRP controller extension from plant 1 to plant 2
    Thanks,
    Swamy H P

  • Runtime error while creating material master data

    hello sir,
    i am facing one prolem while creating MATERIAL MASTER DATA.
    AFTER GIVING ALL REQUIRED INFORMATION WHEN I AM GOING TO SAVE THE DOCUMENT ITS SHOWING ABAP RUNTIME ERROR.
    MESSAGE TYPE: - MDS_KEYMAP.
    MESSAGE CLASS: 001.
    PLEASE TELL ME WHAT TO DO?
    REGARDS..

    SIR THANK YOU FOR YOUR REPLY.
    I ALREADY DONE THAT DUMP ANALYSIS.
    SO PLEASE KINDLY GIVE ME IN DETAILS ABOUT THAT SOLUTION...

  • Error while creating material master

    hi,
    I'm getting this error message when I'm creating a material master in a specific plant/sloc. I'm probably guessing its in config. I really need some help here.
    "Tables TCURM and T001W inconsistent; notify your system administrator" .
    could any one  draw some light on this.
    thanks regards,
    chinta

    this is not application server specific problem.
    Suggest you to go to [Logistic/MM forum|SAP ERP - Logistics Materials Management (SAP MM);.
    regards,
    Vincent

  • Error while trying to change Material master

    Hi ,
    I am getting following error when I am trying to Change material master thru Tcode MM02
    "Required parameter missing when calling up module MARA_SINGLE_READ"
    In fact , I also couldn't select this Material in Purchase order .Error which i am getting is "Faulty Material"
    Could anyone pls help me.
    Regards
    Sandeep marwha

    I created a new material also , but for that also I am getting same error.
    Regards
    Sandeep

Maybe you are looking for

  • Greyed Out Tones and Music.  Tones won't Sync.

    After restoring my new iPhone 6 from backup of an old iPhone 5 via USB, I added my tones and music to my phone.  I have manually manage music checked off.  When I checked my phone, I noticed that not all of the songs were there.  I preceded to downlo

  • How can I open a word-document in word?

    I want to have a link in my java-program to a word-document, but I don't know how to open the document in word from java.

  • Flash Ad External API  not working in IE7

    I'm using the Flash AS 2.0 External API to call a Javascript function in a page that adds an item to a shopping list when a Flash Ad is clicked. This is working in FireFox 2 , Safari, and IE6, but does not work in IE7. I tested the Flash Ad locally i

  • How to analyzer the BI query in VISUAL COMPOSER?

    hi experts, could you please explain me how to analyze the Bex query in VISUAL COMPOSER? could you please provide me the step-by-step documentation if possible?? regards vadlamudi

  • Problem in Std Function module (PSBW_GET_ACTIVITY)

    I am facing the problem at the time of data extraction thru std function module of 0ACTIVITY_ATTR. The name of the module is PSBW_GET_ACTIVITY. BOQ rate is 'z'field and uppended in 0Activity_attr. Functional scenario: We have one Project having 2 wbs