Maximum Number of Components per BOM(Per procurement type,if possible)

Dear Colleagues,
I have been told that certain materials belonging to a  specific procurement type,have their BOM set that it allows only up to 100 components to be built within it.I had a god look on IMG under most relevant categories and can't find where this is defined in...so I'm wondering if you have ever had the request to look at the maximum number of components that could be built under a specific procurement type of material? Generally speaking,where you could define maximum no of components per BOM.At what level this is usualy set up?
All help,greatly appreciated,
PAPJ1.

Thanks Dario.
Allegedly,I have been told that this is set to 100 components per BOm of that particular procurement type,so I need to change it 200 (if that's true and it is allowing me to do so)
PAPJ1.
Edited by: PAPJ1 on Jun 13, 2011 2:03 PM

Similar Messages

  • Panel - Maximum number of components

    Taking a Panel or any Layout (eg.GridLayout), how can I calculate the maximum number of components a panel or layout can hold?

    int counter = 0
    while(true){
      myComponent.add(new JPanel());
      System.out.println(counter++);
    }each layout has a set number of components it can hold. If you cant find documentation on it, run this and look at the last output before it crashes.
    fyi, boxLayout = 512 iirc... a problem I had about a week ago.

  • Maximum number of MRAS requests / allocations per user?

    Hello,
    I have a test C++ SIP application that registers to a Lync edge server and is able to perform MRAS requests to it.
    The MRAS responses allow me to create TURN allocations on the TURN component of the edge server. However, I seem to be hitting a limit with the number of simultaneous TURN allocations I can create with a single registration.  I seem to be able to create
    a maximum of 50 TURN allocations for that single registration.
    Is this a configurable option - either per user / per edge server etc - for the maximum number of TURN allocations a single Lync user can simultaneously have?  Or is there anything else I can put in the SIP/TURN signalling to increase this limit?
    Many thanks,
    Simon

    Hi,
    You may need to custom your own Lync server, so you might post the issue on Lync MSDN forum and more developing expert will help to verify the information using Lync SDK. Thank you for your understanding.
    http://social.msdn.microsoft.com/Forums/en-US/communicatorsdk/threads
    Best Regards,
    Eason Huang
    Eason Huang
    TechNet Community Support

  • Is there a maximum number of "multi state objects" per article? Indesign keeps crashing

    Hi, i have 12 multi state objects on a page, and indesign keeps crashing.
    i know this seems like a high number, but I have done this to create a work around - ticker (like an old style airport board e.g. https://www.google.co.uk/search?q=airport+board&espv=2&biw=1306&bih=653&source=lnms&tbm=is ch&sa=X&ei=TkYUVb3ZJIb0PJ7DgZg… each set of 3 creating one graphic e.g. 3.35
    After creating these Indesign keeps crashing when i try to preview?
    Any advice would be appreciated.

    It sounds like you're running in to a memory problem: Memory Handling in DPS
    That said, usually multiple MSOs on the page don't usually cause memory problems because only the first state of the MSO is loaded into memory. If the first state of each MSO is loading a web overlay displaying ticker information, then that's the most likely culprit. Consider redesigning the page so that only a few tickers are loaded into memory and the user needs to tap to reveal additional tickers.

  • How do I increase the maximum number of list items in the Step Type Menu Editor?

    I am trying to create a lot of custom steps and have reached the point where they no longer appear in the "Insert Step" menu. Message reads "Max Menu Items Reached". Is there a way to increase this maximum?

    Hi,
    You have hit the same problem as I.
    Unfortunately you wont beable to easy resolve this unless you are using TestStand 3.0.
    see here for answer:
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=135&HOID=506500000008000000A98C0000&UCATEGORY_0=_8_&UCATEGORY_S=0
    Using TestStand 3.0 the problem goes away as it is capable of handling more than the 256 step types.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • Maximum number of LUNs per SCSI ID

    (1)What is the maximum number of LUNs (logical units) per SCSI ID for the different Solaris releases (default value) ?
    (2)How can I increase this maximum number (Patches, kernel or driver parameters, ...)?
    (3) Is there any difference whether the devices are attched through SCSI or FC (fibre channel) ?
    As a background. I am currently trying to attach a storage device with a maximum LUN number per ID of 32 to a UE450 (running Solaris 7 with the June00 Patch cluster). The problem is that Solaris only sees LUN 0..15 per SCSI ID. The /kernel/drv/sd.conf file was modified for 32 LUNs.
    Many thanks for any feedback.

    In addition to configuring the SCSI disk driver to support 32 LUNs you also need to configure the underlying SCSI bus driver to support 32 LUNs. With patch 106925-03 (now -04) the PCI SCSI driver, glm, will support upto 32 LUNs if configured in /kernel/drv/glm.conf but defaults to supporting 8. The PCI Fibre Channel driver, ifp, support 16 LUNs (patch 107292).
    If you are using StorEdge RAID, the RAID manager software has a set of shell scripts to configure the drivers and RAID software to support 16 or 32 LUNs.
    Andrew Walton
    Sun Developer Technical Support

  • BOM - Maximum No. of components allowed.

    Hello,
    Is there any Limit of Maximum number of Components that can exist in a BOM.  i.e for ex. in CS01, is there any limit that only 999 components are allowed by SAP or something like that?
    Regards,
    Bharat.

    9999 is the limit for items

  • Maximum number of simultaneous Template requests

    I am running a CF-server (standard) on a
    Intel(R) Xeon(R) CPU           E5420  @ 2.50GHz, 8 cores
    I have read somewhere on the net that you can set 8-10 maximum number of simultaneous template requests per core, which in my case
    would be 64-80 simultaneous template requests.
    Is that a correct assumption?
    This does feel quite high considering the default value of the server is 10 simultaneous requests.
    //Toby

    It is the common rule of thumb, but that does not make it the correct or incorrect assumption.
    What it does make is a common and usefull starting point, with the strong assumption that one will then load test ones system to make sure the setting accually works well with ones applications and hardware.  And that one will then adjust accordingly based on the testing.

  • What is the Maximum Number of Concurrent Sessions allowed on a Shared Exchange Mailbox ?

    Hi,
    I have a query that how many concurrent sessions are allowed on a Resource Mailbox ?
    E.g. I have a scenario in which i run a Helpdesk, and it has an email address ([email protected]), where company employees can email thier IT Issues/requests.
    Now I have hired say 50 Service Desk agents, now is it possible that all 50 can access the IThelpdesk mailbox at one time ? Are there any limits on the number of the concurrent sessions of the mailbox ? What are the the permutations and combinations in this
    case ?
    ** The mailbox is on Exchange Server 2003**
    Regards,
    Tojo Thankachan
    +91 7875039665

    Hi,
    Exchange Server 2003 SP1 imposes a restriction on the number of permitted MAPI sessions per user. By default, the maximum number of permitted MAPI sessions per user is set to a hexadecimal value of 0x20 after you apply Exchange Server 2003 SP1.
    Generally, Event ID 9646 will be logged in the application event log of your Exchange Server 2003 computer when a client opens many MAPI sessions. Here is a KB descripted the details of it:
    http://support.microsoft.com/kb/842022
    For more information about MAPI session limit, please refer to:
    http://technet.microsoft.com/en-us/library/dd159906(v=exchg.80).aspx
    Thanks,
    Winnie Liang
    TechNet Community Support

  • Maximum no of Components in Xcelsius

    Hi,
    Has anyone any idea if SAP is coming up with any document which can guide upon various issues we usually face with Xcelsius:-
    Like No of Rows?
    No. Of Connections
    No. of Components?
    I am working on a dashboard for a client which has 242 Components. Some of the users can open the generated SWF but some cannot. And if I reduce no. of compoents to 176 everyone can open that.
    Inspite of that I am unable to convience the client to change the approach because there is no document/guidelines from SAP about it.
    Appreciate your answers!
    Regards

    The maximum number of components depends mainly on the memory the flash player can allocate.
    XCelsius is a tool for displaying consolidated infromation (ie. a small number of data rows). It is tempting to exploit the graphical capabilities of it by using a large number of components by you should keep an eye on the performance.
    Since the same XCelsius component or data connection can consume a different amount of memory every time depending  eg. on the data displayed or fetched, the only meaningful guideline here is to make sure that your design fullfills your performance criteria by testing it using multiple test scenarios.
    BTW If you need to have complex logic which processes mass data with high graphical (even interactive) requirements maybe you should consider using Cystal Rports with embedded XCelsius dashboards.
    Regards
    Stratos
    PS: eg. Microsoft does not provide a recommendation regarding the number of f graphical shapes a Word document should contain.

  • Error message "Maximum number of drilldown characteristics exceeded"

    Hello,
    an user created a Web report. In the navigation block there are nearly 100 selection fields. If you make either "drilldown in the rows" or "drilldown in the columns" you recieve after 50 drilldowns the error message "Maximum number of drilldown characteristics exceeded" and it is not possible to proceed further. Does anybody has got an idea what this can be?
    Thanks!
    Regards,
    Christian

    Hi Check SAP Note No -
    Note 144478 - BEx: Termination/Message at 10th/20th drilldown characterstc
    1. Terminations occur when you drill down a large number of characteristics at the same time during interactive navigation in the Business Explorer Analyzer (Excel).
    2. In the global query definition, the system displays message 'Termination: the maximum number (10/20) of drilldown characteristics is exceeded' if the total of the characteristics and structures you are using exceeds
                  - 10 objects in Release 1.2B
                  - 20 objects in Release 2.0A/2.0B/2. 1C
                  during the definition of a query.
    Hope it helps
    regards
    Vikash

  • ORA-20001: Maximum number of email messages per workspace exceeded

    Greetings. We are running APEX 4.1.1. I have an application where we have to send out email messages to a list of emails. Currently there are 2469 email addresses. Originally we put the email addresses in the BCC but we received an error that we had exceeded the size limit of the BCC. So we modified our procedure to send one email at a time, in a loop.
    Now we are receiving the following error message:
    "ORA-20001: You have exceeded the maximum number of email messages per workspace"
    Has anyone else run into this issue? What is maximum number or email messages per workspace? Is it a limit per day, per session?
    We have not added emails to this table since last year, so the maximum number of email messages allowed may have changed recently?
    I did find this Forum post that addressed the issue but no one responded:
    How many mails i can send at a time per day using APEX mail system?
    Thanks,
    John

    Hi jfosteroracle,
    You are getting the error may be the following reason,
    Check the following,
    Login as ADMIN and Goto -->Manage Instance-->Instance Settings--> Mail-->Maximum Emails per workspace
    Actually this number denotes the Number of mails can be sent per 24 hour for the workspace,It may exceeded.
    It may be the reason.
    Thank you.     
    Regards,
    Gurujothi
    Edited by: Gurujothi on Jun 27, 2012 5:54 AM

  • Maximum number of events per audit log file must be greater than 0.

    BOE-XI (R2)
    Windows Server 2003
    Running AUDIT features on all services.
    Report Application Server (RAS) keeps giving the following error in the Windows Application Event Log.
    Maximum number of events per audit log file must be greater than 0.  Defaulting to 500.
    I am assuming that this is because the RAS is not being used by anyone at this time - and there is nothing in the local-audit-log to be copied to the AUDIT database.
    Is there any way to suppress this error...?
    Thanks in advance for the advice!

    A couple more reboots after applying service pack 3 seemed to fix the issue.
    Also had to go to IIS and set the BusinessObjects and CrystalEnterprise11 web sites to use ASP .NET 1.1 instead of 2.

  • How to change the maximum number of process per user in BW ?

    Hi,
    Do you know how to change the maximum number of process allowed per user ?
    With RSRT we can customize the number of process per query but I don't know where we can customize the maximum number of process per user.
    In fact, my production environment reach always the max number of process available in SM50...
    Thanks a lot

    Hi,
    A user is not have the No. of processor but a work process can handle N No. of users. If a user hit any transaction v acn say from  a list of N worl proceesor which has been taken the work.
    Correct if I am wrong.
    Regards
    Syed.

  • Maximum number of users Per Conference on monthly reports

    Can anyone has SQl query to fetch the maximum number of users per conference in Lync 2010 on monthly basis .
    in monitoring report this report is not coming so please give some workaround .
    Ashwani Thapa

    Have you seen this? http://blogs.technet.com/b/rischwen/archive/2014/01/17/per-user-conference-joins-grouped-by-uritype-sql-query.aspx
    If this helped you please click "Vote As Helpful" if it answered your question please click "Mark As Answer"
    Georg Thomas | Lync MVP
    Blog www.lynced.com.au | Twitter
    @georgathomas
    Lync Edge Port Check (Beta)
    This forum post is my own opinion and does not necessarily reflect the opinion or view of Microsoft, its employees, or other MVPs.

Maybe you are looking for