The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
As Glen aready noted, the limit is nine for data stacking (StackWise).  3750-X power stacking (Stack Power), between stack members, is limited to 4.
Also note, large 3750 stacks can sometimes be very sluggish doing some CLI commands.
And also note, although StackWise Plus supports "spacial reuse" for unicast traffic, large stacks might congest the ring sooner.
Lastly, for very large stacks, a chassis might be a better and/or less expensive solution.

Similar Messages

  • Maximum number of switches in a LAN

    Hello
    I have one question about the maximum number of switches (layer 2 only) that we could connect together in a LAN.
    I think is 7.
    In the case that we want to install more that 7 what are the STP parameters what we must change ?
    thank you for your answers.

    Hi Mauricio,
    The figure that you are talking baout is the diameter of STP i.e 7. Thhis is the number of hops to which STP spans properly and does the STP calculations as expected. After 7 hops you might see unexpected results and it depends. There is no limit of the switches that you can put in you N/W it all dpends upon the N/W, Number of nodes i.e users and requrement. So in case if you are trunking switches to your Core/Distribution switches make sure that you should not cross the 7 hops STP diameter.
    HTH,
    -amit singh

  • What is the max number of 3850 switches in a stack

    This doc states 4.  Has there been any change to allow more?
    http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-3850-series-switches/qa_c67-722110.html

    Up to 9 Cisco Catalyst 3850 switches can be stacked together to build single logical StackWise-480 switch since Cisco IOS XE Release 3.3.0SE.
    Prior to Cisco IOS XE Release3.3.0SE, up to 4 Cisco Catalyst 3850 switches could be stacked together.
    http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-3850-series-switches/qa_c67-722110.html

  • Maximum number of columns  in a table or view is 1000

    Post Author: TinaReifer
    CA Forum: Formula
    I am trying to create a direct link from Tririga / Oracle database into Crystal XI.  The data I am attempting to pull is from the RETransaction (Escalations). The error I keep receiving is shown below.  Has anyone run across this problem and found a solution that can be shared?
    Very Appreciative for any feedback.
    Tina Reifer
    "Failed to retrieve data from the database.
    Details: HY000:[Oracle][ODBC][Ora]ORA-01792: maximum number of columns  in a table or view is 1000
    [Database Vendor Code:  1792]"

    Post Author: synapsevampire
    CA Forum: Formula
    Try posting your software, its version, and the type of connectivity you're using for oracle.
    Older versions of Crystal used a proprietary Oracle ODBC driver that came with Crystal, but you should SWITCH away from using ODBC anyway, not sure why you elected to use it, it's slower and more problematic.
    You'll see Oracle Server listed as a data source, that is generally the best connectivity to use.
    Also, what version of Oracle is it, and what Oracle client are you using?
    You might need your Oracle dbas assistance here.
    Anyway, the error is not a Crystal error, it's being raised by the ODBC driver, and Oracle used to have a maximum of 1024 colums I think it was...been a while...
    -k

  • Java.lang.Exception: ORA-00020: maximum number of processes (150) exceeded?

    When i run my web-application with the embedded OC4J server, the following error message is prompted:
    java.lang.Exception: ORA-00020: maximum number of processes (150) exceeded
         void MyFolder.objects.MyObject.<init>(oracle.jbo.ApplicationModule, java.lang.String, java.lang.String, javax.servlet.http.HttpServletRequest)
         void MyFolder.servlet.MyServlet.doPost(javax.servlet.http.HttpServletRequest, javax.servlet.http.HttpServletResponse)
         void javax.servlet.http.HttpServlet.service(com.evermind.server.http.EvermindHttpServletRequest, com.evermind.server.http.EvermindHttpServletResponse)
         void javax.servlet.http.HttpServlet.service(javax.servlet.http.HttpServletRequest, javax.servlet.http.HttpServletResponse)
         void javax.servlet.http.HttpServlet.service(javax.servlet.ServletRequest, javax.servlet.ServletResponse)
         void com.evermind.server.http.ServletRequestDispatcher.invoke(javax.servlet.ServletRequest, javax.servlet.ServletResponse)
         void com.evermind.server.http.ServletRequestDispatcher.forwardInternal(javax.servlet.ServletRequest, javax.servlet.http.HttpServletResponse)
         boolean com.evermind.server.http.HttpRequestHandler.processRequest(com.evermind.server.ApplicationServerThread, com.evermind.server.http.EvermindHttpServletRequest, com.evermind.server.http.EvermindHttpServletResponse, java.io.InputStream, java.io.OutputStream, boolean)
         void com.evermind.server.http.HttpRequestHandler.run(java.lang.Thread)
         void com.evermind.util.ThreadPoolThread.run()
    Question:
    - What is the cause of this error message? How to avoid?
    - I intended to deploy my application to 9IAS server. Will the same problem occurs too?
    Thanks for your reply!

    Hi Pig,
    When i run my web-application with the embedded OC4J server, the following error message is prompted:
    java.lang.Exception: ORA-00020: maximum number of processes (150) exceeded
         void MyFolder.objects.MyObject.<init>(oracle.jbo.ApplicationModule, java.lang.String, java.lang.String, javax.servlet.http.HttpServletRequest)
         void MyFolder.servlet.MyServlet.doPost(javax.servlet.http.HttpServletRequest, javax.servlet.http.HttpServletResponse)
         void javax.servlet.http.HttpServlet.service(com.evermind.server.http.EvermindHttpServletRequest, com.evermind.server.http.EvermindHttpServletResponse)
         void javax.servlet.http.HttpServlet.service(javax.servlet.http.HttpServletRequest, javax.servlet.http.HttpServletResponse)
         void javax.servlet.http.HttpServlet.service(javax.servlet.ServletRequest, javax.servlet.ServletResponse)
         void com.evermind.server.http.ServletRequestDispatcher.invoke(javax.servlet.ServletRequest, javax.servlet.ServletResponse)
         void com.evermind.server.http.ServletRequestDispatcher.forwardInternal(javax.servlet.ServletRequest, javax.servlet.http.HttpServletResponse)
         boolean com.evermind.server.http.HttpRequestHandler.processRequest(com.evermind.server.ApplicationServerThread, com.evermind.server.http.EvermindHttpServletRequest, com.evermind.server.http.EvermindHttpServletResponse, java.io.InputStream, java.io.OutputStream, boolean)
         void com.evermind.server.http.HttpRequestHandler.run(java.lang.Thread)
         void com.evermind.util.ThreadPoolThread.run()
    Question:
    - What is the cause of this error message? How to avoid?.
    From the Oracle error message documentation:
    ORA-00020 maximum number of processes (string) exceeded
    Cause: All process state objects are in use.
    Action: Increase the value of the PROCESSES initialization parameter.
    Another alternative approach may be to configure your Connection pool and/or your ApplicationModule pool to optimize the use of
    database connections and/or restrict the number of database connections used by the application. For example, if your application
    has declared many root ApplicationModules (i.e. more than one ApplicationModule pool is in use) then it may help to enable the
    jbo.doconnectionpooling switch so that each ApplicationModule instance in the pools does not maintain a dedicated database
    connection while not in use. Another alternative if you are using the BC4J connection pool (not a JDBC datasource) may be to
    restrict the number of connections the pool can create to < 150 with the jbo.maxpoolsize switch. However, please note that this
    may have an impact on throughput.
    - I intended to deploy my application to 9IAS server. Will the same problem occurs too?.
    This is a database issue. So, yes.
    Hope this helps.
    JR

  • Nokia N8-00 'maximum number of connections in use'

    Hi,
    I have creted another APN in the Destinations-Internet settings. Put this APN on priority 1. Then I se internet an it is ok. But when I open Nokia Maps or another App. Sometimes it tries to connect to the old APN then says 'maximum number of connections in use'. Asking me for confirmation to close one connection.
    So I move all APN's and Wireless connections out of the Destination Internet. Except for the new on that I want. Still the same message From time to time. How to stop thi message. Deleting an APN is not a solution I am looking for otherwise I would have done that.
    Any help is appreciated.

    So the on off method I posted earlier did not work. The first APN is still tring to be accessed by some apps after the phone is switched off and on again. The other things I tried..
    - Removed the APN restriction and renamed the first APN. When I start the APP it now gives me a warning and lets me choose the APN. I choose the second one so greate. Close the APP. Now when I rename the fisr APN to the original name. APPS try to access it again and I get that original error.
    The only thing I could do is configure the first APN name with the actual Access Point of the second APN. This worked All apps are accessing the first APN whaich was reconfigured to look like the new Second APN. 
    This is not a solution again it is a workaround. Does anyone-else have this problem. Or am I the only one who is configuring multiple APNs. Since my provider has multiple APNs.
    I would have thought that this phone supports Multiple PDP contexts, or Secondary PDP context. It was defined in the initial 3GPP specs way back in 2003ish. Nokia can you confirm???
    Cheers Peps!

  • Maximum number of vlans and HSRPs can be created?

    Hi,
    would appreciate if anyone can advise what is the maximum number of vlans as well as HSRP can be created? Is it the same for all layer 2 and 3 switches?
    Thanks
    Christina

    VLANs - about 4096 - switch dependent
    HSRP - 16 groups max

  • Maximum Number of Simultaneous Accounts?

    Is there a maximum number of accounts I can have running at the same time? I have fast user switching turned on and would like to run up to 10 accounts at a time.

    Daniel,
    I don't see why not, but then I also don't see what possible reason you would have for doing this. Keep in mind that your MBP may become very sluggish with this many accounts active at one time, especially if you do not have your RAM maxed out.
    Scott

  • Maximum number of CAT3560's that can be connected

    What is the maximum number of Cat 3560 switches that can be connected together. Using all Fiber ports the max number would be 5, does this series of switch have a design limitation on how many can be connected together?

    you could theoretically connect a switch to every port of the 3560.
    this may not be best design for STP and broadcast domain purposes but would be possible. (depending on what you're trying to accomplish)
    do you mean how many max daisy-chained one after the other??

  • Maximum number of interfaces in Port Channel on Nexus 5596

    Let me preface this by saying I am not a network expert....
    I noticed that our customer had configured a port channel on their Nexus 5596 comprised of 16 interfaces. I thought the maximum number of interfaces in a port channel was 8 interfaces? I see in the Nexus 7000 documentation that if you configure 16 interfaces, the remaining 8 will be in "hot standby." Is this the same behavior on the Nexus 5000 series?
    Thank you.

    Same behavior on the 5500 series and other Cisco switches like 3750, 3850 , etc..
    HTH

  • Maximum number of buttons (HELP)

    i have a project where i need 24 buttons. i have a project with 24 subtitles and on the main menu, i want to put all the languages so a viewer can select their language and then watch their subtitled version. the maximum number of buttons allowed on a 16:9 project is 18. does anyone have any solutions??

    LOL!
    I was a teacher once... and not been called smart since I threw away my suit to go to work in...
    It's as Eric said - you are creating an illusion using two menus that are identical. Menu 1 has 18 buttons that work, but has a background image that appears to show 24 buttons. The 18th button is invisible and auto-activates to menu 2, where you land on a button that is labelled as button 18. This menu has a background image that has the graphics for buttons 1-17 but no actual buttons in those positions.
    The trick is accomplished because as you move between buttons (using the remote) the last in the list (button 18) will jump to menu 2, where the real button 18 is actually the first on the new menu. Remember, the default button is usually the first you create (unless you specifically change this) so the user will see what looks like buttons 1-17 as a background image for menu2, and will appear to be on button 18, but will in fact be on button 1 of menu 2.
    You'll need another invisible button on menu 2 that is positioned above the default button so that the user can move 'up' from what they believe to be button 18. When they do so, the invisible button will auto-activate and go to the first menu, landing on button 17.
    There will be a pause as all this switching around takes place.
    This illusion prevents you from needing to use navigational arrows on the menus and the user can be fooled into thinking there are more than 18 buttons on a 16x9 menu.
    A different way to do what you want is to use a track as a menu, and use buttons over video. Works like a menu, but isn't restricted in the same way... but also doesn't provide some menu features, and you'll need to build it carefully.
    BoV uses an image set into a track and an overlay file, but then you create buttons using the subtitle stream. In essence you create a track, add the graphic for the background. You make sure the start marker is set to be a button highlight marker and then add a subtitle. With the subtitle active you can add button rectangles just as if you were in a menu and if you add the overlay file you can add all kinds of highlight shapes. Navigation and colours work the same as for menus, but remember a subtitle can only really have four colours - you'll perhaps need to compromise somewhere along the way in terms of how this all looks.
    It's an interesting challenge - I would like to hear how you get on with it.

  • Windows Azure Active Directory MA - Maximum number of items that can be serialized or deserialized in an object graph is '500000'. Change the object graph or increase the MaxItemsInObjectGraph quota.

    Trying to use WAAD with FIM 2010 R2 SP1 (4.1.3496.0) and during export several objects cause a warning/info with:
    Maximum number of items that can be serialized or deserialized in an object graph is '500000'. Change the object graph or increase the MaxItemsInObjectGraph quota.
    I looked, this appears hard coded into the MA, anyone know what causes this? My best guess is something like a large group membership? Does anyone know what the limits around the WAAD MA are?
    Here is the indepth error logged during the failure:
    ProvisioningServiceAdapter::ExecuteWithRetry: Action: Export, Attempt: 0, Exception: Microsoft.Online.Coexistence.ProvisionRetryException: Unable to communicate with the Windows Azure Active Directory service. Tracking ID: e94e6020-8434-4aa7-9a29-b2edf7fe6b2e
    See the event log for more details. ---> System.ServiceModel.CommunicationException: There was an error while trying to serialize parameter http://schemas.microsoft.com/online/aws/change/2010/01:syncObjects. The InnerException message was 'Maximum number
    of items that can be serialized or deserialized in an object graph is '500000'. Change the object graph or increase the MaxItemsInObjectGraph quota. '.  Please see InnerException for more details. ---> System.Runtime.Serialization.SerializationException:
    Maximum number of items that can be serialized or deserialized in an object graph is '500000'. Change the object graph or increase the MaxItemsInObjectGraph quota.
       at System.Runtime.Serialization.XmlObjectSerializerContext.IncrementItemCount(Int32 count)
       at WriteArrayOfstringToXml(XmlWriterDelegator , Object , XmlObjectSerializerWriteContext , CollectionDataContract )
       at System.Runtime.Serialization.CollectionDataContract.WriteXmlValue(XmlWriterDelegator xmlWriter, Object obj, XmlObjectSerializerWriteContext context)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.SerializeAndVerifyType(DataContract dataContract, XmlWriterDelegator xmlWriter, Object obj, Boolean verifyKnownType, RuntimeTypeHandle declaredTypeHandle, Type declaredType)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.SerializeWithXsiType(XmlWriterDelegator xmlWriter, Object obj, RuntimeTypeHandle objectTypeHandle, Type objectType, Int32 declaredTypeID, RuntimeTypeHandle declaredTypeHandle, Type
    declaredType)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.InternalSerialize(XmlWriterDelegator xmlWriter, Object obj, Boolean isDeclaredType, Boolean writeXsiType, Int32 declaredTypeID, RuntimeTypeHandle declaredTypeHandle)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.InternalSerializeReference(XmlWriterDelegator xmlWriter, Object obj, Boolean isDeclaredType, Boolean writeXsiType, Int32 declaredTypeID, RuntimeTypeHandle declaredTypeHandle)
       at WriteSyncObjectGroupToXml(XmlWriterDelegator , Object , XmlObjectSerializerWriteContext , ClassDataContract )
       at System.Runtime.Serialization.ClassDataContract.WriteXmlValue(XmlWriterDelegator xmlWriter, Object obj, XmlObjectSerializerWriteContext context)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.SerializeAndVerifyType(DataContract dataContract, XmlWriterDelegator xmlWriter, Object obj, Boolean verifyKnownType, RuntimeTypeHandle declaredTypeHandle, Type declaredType)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.SerializeWithXsiType(XmlWriterDelegator xmlWriter, Object obj, RuntimeTypeHandle objectTypeHandle, Type objectType, Int32 declaredTypeID, RuntimeTypeHandle declaredTypeHandle, Type
    declaredType)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.InternalSerialize(XmlWriterDelegator xmlWriter, Object obj, Boolean isDeclaredType, Boolean writeXsiType, Int32 declaredTypeID, RuntimeTypeHandle declaredTypeHandle)
       at System.Runtime.Serialization.XmlObjectSerializerWriteContext.InternalSerializeReference(XmlWriterDelegator xmlWriter, Object obj, Boolean isDeclaredType, Boolean writeXsiType, Int32 declaredTypeID, RuntimeTypeHandle declaredTypeHandle)
       at WriteArrayOfSyncObjectToXml(XmlWriterDelegator , Object , XmlObjectSerializerWriteContext , CollectionDataContract )
       at System.Runtime.Serialization.CollectionDataContract.WriteXmlValue(XmlWriterDelegator xmlWriter, Object obj, XmlObjectSerializerWriteContext context)
       at System.Runtime.Serialization.DataContractSerializer.InternalWriteObjectContent(XmlWriterDelegator writer, Object graph, DataContractResolver dataContractResolver)
       at System.Runtime.Serialization.DataContractSerializer.InternalWriteObject(XmlWriterDelegator writer, Object graph, DataContractResolver dataContractResolver)
       at System.Runtime.Serialization.XmlObjectSerializer.WriteObjectHandleExceptions(XmlWriterDelegator writer, Object graph, DataContractResolver dataContractResolver)
       at System.ServiceModel.Dispatcher.DataContractSerializerOperationFormatter.SerializeParameterPart(XmlDictionaryWriter writer, PartInfo part, Object graph)
       --- End of inner exception stack trace ---
    Server stack trace:
       at System.ServiceModel.Dispatcher.DataContractSerializerOperationFormatter.SerializeParameterPart(XmlDictionaryWriter writer, PartInfo part, Object graph)
       at System.ServiceModel.Dispatcher.DataContractSerializerOperationFormatter.SerializeParameter(XmlDictionaryWriter writer, PartInfo part, Object graph)
       at System.ServiceModel.Dispatcher.DataContractSerializerOperationFormatter.SerializeParameters(XmlDictionaryWriter writer, PartInfo[] parts, Object[] parameters)
       at System.ServiceModel.Dispatcher.DataContractSerializerOperationFormatter.SerializeBody(XmlDictionaryWriter writer, MessageVersion version, String action, MessageDescription messageDescription, Object returnValue, Object[] parameters, Boolean
    isRequest)
       at System.ServiceModel.Dispatcher.OperationFormatter.OperationFormatterMessage.OperationFormatterBodyWriter.OnWriteBodyContents(XmlDictionaryWriter writer)
       at System.ServiceModel.Channels.Message.OnWriteMessage(XmlDictionaryWriter writer)
       at System.ServiceModel.Channels.BufferedMessageWriter.WriteMessage(Message message, BufferManager bufferManager, Int32 initialOffset, Int32 maxSizeQuota)
       at System.ServiceModel.Channels.BinaryMessageEncoderFactory.BinaryMessageEncoder.WriteMessage(Message message, Int32 maxMessageSize, BufferManager bufferManager, Int32 messageOffset)
       at System.ServiceModel.Channels.HttpOutput.SerializeBufferedMessage(Message message)
       at System.ServiceModel.Channels.HttpOutput.Send(TimeSpan timeout)
       at System.ServiceModel.Channels.HttpChannelFactory`1.HttpRequestChannel.HttpChannelRequest.SendRequest(Message message, TimeSpan timeout)
       at System.ServiceModel.Channels.RequestChannel.Request(Message message, TimeSpan timeout)
       at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout)
       at System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation)
       at System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message)
    Exception rethrown at [0]:
       at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
       at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
       at Microsoft.Online.Coexistence.Schema.IProvisioningWebService.Provision(SyncObject[] syncObjects)
       at Microsoft.Online.Coexistence.ProvisionHelper.InvokeAwsAPI[T](Func`1 awsOperation, String opsLabel)
       --- End of inner exception stack trace ---
       at Microsoft.Online.Coexistence.ProvisionHelper.CommunicationExceptionHandler(CommunicationException ex)
       at Microsoft.Online.Coexistence.ProvisionHelper.InvokeAwsAPI[T](Func`1 awsOperation, String opsLabel)
       at Microsoft.Azure.ActiveDirectory.Connector.ProvisioningServiceAdapter.<>c__DisplayClass1.<Export>b__0()
       at Microsoft.Azure.ActiveDirectory.Connector.ProvisioningServiceAdapter.ExecuteWithRetry(String actionName, Action action).

    Hi gdedshg,
    >>Maximum number of items that can be serialized or deserialized in an object graph is '65536'. Change the object graph or increase the MaxItemsInObjectGraph quota
    When meet the above exception, please try to do the following configuration:
    On the server side:
    Add the following to the server's config file:
    <behaviors>
    <serviceBehaviors>
    <behavior name="MyServiceBehavior">
    <dataContractSerializer
    maxItemsInObjectGraph="2147483647" />
    </behavior>
    </serviceBehaviors>
    </behaviors>
    And reference it in the service using the following code:
    <services>
    <service
    behaviorConfiguration="MyServiceBehavior"
    name="serviceName">……
    On the client side:
    Add the following: 
    <behaviors>
    <endpointBehaviors>
    <behavior name="MyClientbehavior">
    <dataContractSerializer
    maxItemsInObjectGraph="2147483647"/>
    </behavior>
    </endpointBehaviors>
    </behaviors>
     And reference it in the endpoint using the following code:
    <endpoint address="serviceAddress"
    behaviorConfiguration="MyClientbehavior"
    For more information, please try to refer to the following article:
    http://blog.aggregatedintelligence.com/2011/01/wcf-maxitemsinobjectgraph-error.html .
    Best Regards,
    Amy Peng
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • SG300 Cannot enable IPv6 on the interface - the maximum number of interfaces 3 has already been used.

    The Sg300 is currently in L3 mode
    Why is it that only 3 IPv6 interfaces are being allowed?
    No where in the device specifications or in the documentation did I ever see this limitation when I purchased the switch!

    That message it means that you will not be able to create another iCloud account on your device as the maximum number have already been created.  Your only options are to either re-use one of the accounts previously created, or create your new account using on a different iOS device or Mac, if you have one.

  • Maximum number of fabric logins

    Hi there
    I need to provide documented references for a large SAN, and have a few queries.
    I have the show tech-supports for an edge-core-edge SAN consisting of 2 redundant fabrics.
    There are 4 host edges, 1 core, 4 storage edges per fabric. All are MDS 9500 series directors, running SAN-OS 3.2.2a.
    In the Large SAN Design Best Practices whitepaper
    (http://www.cisco.com/en/US/prod/collateral/ps4159/ps6409/ps5990/white_paper_C11-515630.pdf)
    there is a reference to the maximum number of fabric logins.
    "The Cisco MDS Family supports up to 10,000 fabric logins in a physical fabric, regardless of the number of VSANs in the network."
    1) Is this specifically refering to the number of f_ports?
    2) If not, what is the 10,000 referring to?
    In the Cisco MDS NX-OS Release 5.0 Configuration Limits
    (http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/5_0/configuration/guides/limits/limits_50.html)
    there is a mention of 10000 FCNS entries per fabric.
    This is the only reference I can find that correlates the two limits.
    The Configuration Limits for Cisco MDS SAN-OS Release 3.x
    (http://www.cisco.com/en/US/products/ps5989/prod_troubleshooting_guide_chapter09186a0080679fd4.html)
    makes no mention of FCNS or fabric login limits.
    3) Is the reference to 10000 FCNS entries (in the NX-OS 5 limits) also the number of fabric logins?
    In the show tech-support, there is a command
    `show tech-support fcns`
    `show fcns database vsan 1-4093`
    VSAN 431:
    FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
    0x050002    N     50:06:04:8c:52:a6:c0:69 (EMC)           scsi-fcp 253
    0x050003    N     50:06:04:84:52:a6:c0:49 (EMC)           scsi-fcp:both 253
    0x050004    N     50:06:04:8c:52:a6:c0:49 (EMC)           scsi-fcp 25
    <.. output abbreviated for brevity>>
    Total number of entries = 1066
    4) Does this mean that there are 1066 fabric logins?
    When I look further in to it, and see the command
    `show fcns database detail vsan 1-4093`
    VSAN:431   FCID:0x0500b1
    port-wwn (vendor)           :10:00:00:00:c9:72:4d:9c (Emulex)   
                                 [nus157_hba0_0]
    node-wwn                    :20:00:00:00:c9:72:4d:9c
    class                       :3
    node-ip-addr                :0.0.0.0
    ipa                         :ff ff ff ff ff ff ff ff
    fc4-types:fc4_features      :ipfc scsi-fcp
    symbolic-port-name          :
    symbolic-node-name          :Emulex LPe11002-S FV2.82a4 DV2.50o
    port-type                   :N
    port-ip-addr                :0.0.0.0
    fabric-port-wwn             :21:07:00:0d:ec:3a:44:c0
    hard-addr                   :0x000000
    permanent-port-wwn (vendor) :10:00:00:00:c9:72:4d:9c (Emulex) 
    It shows that most of the entries have the port-type: N.
    5) Does this mean they are N_ports, not F_ports?
    I would really appreaciate answers to these questions.

    John,
    Cisco NXOS Configuration Limits (reference/background link)
    1) Is this specifically refering to the number of f_ports?
         Answer: Yes, the 10k logins in the Design Guide Whitepaper refer to the number of Fabric logins, not the number of physical ports.  This is because you could have a single F_Port that has multiple logins as part of it.  For example, an Nexus 5000 in NPV mode could connect to a MDS 9513 via one F_port (NP_Port on the Nexus 5k), but have many Fabric Logins (technically, one FLOGI and multiple FDISC).
    2) If not, what is the 10,000 referring to?
         Answer: Number of devices logged into the Fabric not the number of ports in the fabric.
    3) Is the reference to 10000 FCNS entries (in the NX-OS 5 limits) also the number of fabric logins?
         Answer: Yes, since every device out there that FLOGIs into the fabric registers with the nameserver.
    4) In the below output does this mean that there are 1066 fabric logins?
    In the show tech-support, there is a command
    `show tech-support fcns`
    `show fcns database vsan 1-4093`
    VSAN 431:
    FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
    0x050002    N     50:06:04:8c:52:a6:c0:69 (EMC)           scsi-fcp 253
    0x050003    N     50:06:04:84:52:a6:c0:49 (EMC)           scsi-fcp:both 253
    0x050004    N     50:06:04:8c:52:a6:c0:49 (EMC)           scsi-fcp 25
    <.. output abbreviated for brevity>>
    Total number of entries = 1066
    Answer: Yes.
    5) Does this mean they are N_ports, not F_ports?
    When I look further in to it, and see the command
    `show fcns database detail vsan 1-4093`
    VSAN:431   FCID:0x0500b1
    port-wwn (vendor)           :10:00:00:00:c9:72:4d:9c (Emulex)   
                                 [nus157_hba0_0]
    node-wwn                    :20:00:00:00:c9:72:4d:9c
    class                       :3
    node-ip-addr                :0.0.0.0
    ipa                         :ff ff ff ff ff ff ff ff
    fc4-types:fc4_features      :ipfc scsi-fcp
    symbolic-port-name          :
    symbolic-node-name          :Emulex LPe11002-S FV2.82a4 DV2.50o
    port-type                   :N
    port-ip-addr                :0.0.0.0
    fabric-port-wwn             :21:07:00:0d:ec:3a:44:c0
    hard-addr                   :0x000000
    permanent-port-wwn (vendor) :10:00:00:00:c9:72:4d:9c (Emulex) 
    It shows that most of the entries have the port-type: N.
    Answer: An N_Port is an end device like a storage port or an HBA, which connects to an F_Port (Fabric Port) which is the corresponding port on the switch.  This is why you see it as an port-type of N, rather than NL (Node Loop) F, E, or FL (Fabric Loop), as only N or NL can represent the end device itself and not the port on the switch.
    Hope this helps,
    Seth

  • ORA-00020: maximum number of processes 1000 exceeded

    Hello,
    Oracle 10.2.0.4.0
    O/S: Windows Server 2003-64 bits
    RAM: 32Gb
    Instance: opext
    show SGA
    Total System Global Area 10284433408 bytes
    Fixed Size 2180960 bytes
    Variable Size 1574353056 bytes
    Database Buffers 8690597888 bytes
    Redo Buffers 17301504 bytes
    Today at 8:01 am we've got this error:
    ORA-00020: maximum number of processes 1000 exceeded
    That incident was reported in a trace file (opext_ora_8240.trc):
    Dump file c:\oracle\product\10.2.0\admin\opext\bdump\opext_ora_8240.trc
    Tue Jul 31 08:01:03 2012
    ORACLE V10.2.0.4.0 - 64bit Production vsnsta=0
    vsnsql=14 vsnxtr=3
    Oracle Database 10g Release 10.2.0.4.0 - 64bit Production
    Windows NT Version V5.2 Service Pack 2
    CPU : 8 - type 8664, 1 Physical Cores
    Process Affinity : 0x0000000000000000
    Memory (Avail/Total): Ph:18773M/32767M, Ph+PgF:66964M/80966M
    Instance name: opext
    Redo thread mounted by this instance: 1
    Oracle process number: 0
    Windows thread id: 8240, image: ORACLE.EXE
    ORA-00020: maximum number of processes 1000 exceeded
    Died during process startup with error 20 (seq=212441)
    OPIRIP: Uncaught error 20. Error stack:
    ORA-00020: maximum number of processes (1000) exceededThis was the first time in three years that happened an incident like this. Due my Windows server allows me to setup processes and sessions with a very high value, I did it when configuring this database for the first time.
    select resource_name,initial_allocation, limit_value from V$RESOURCE_LIMIT;
    RESOURCE_NAME     INITIAL_ALLOCATION     LIMIT_VALUE
    processes     1000     1000
    sessions     1105     1105
    transactions     1215     UNLIMITEDI would like to know what application or process made that my database exceeds 1000 processes. I read that one possiblity is that there's a web app that open many connections to database and doesn't close them.
    In my listener.log, I got this at 08:05 am:
    31-JUL-2012 08:05:41 * service_update * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36578)) * establish * opext * 0
    31-JUL-2012 08:05:47 * service_update * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36579)) * establish * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36580)) * establish * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36581)) * establish * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36582)) * establish * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36583)) * establish * opext * 0
    31-JUL-2012 08:05:47 * (CONNECT_DATA=(SERVICE_NAME=opext)(CID=(PROGRAM=c:\windows\system32\inetsrv\w3wp.exe)(HOST=SRVXXX)(USER=NETWORK?SERVICE))) * (ADDRESS=(PROTOCOL=tcp)(HOST=192.168.1.1)(PORT=36584)) * establish * opext * 12518
    TNS-12518: TNS:listener could not hand off client connection
    TNS-12560: TNS:protocol adapter error
    Host SRVXXX is a server where a web app is and 192.168.1.1 is our firewall. May I think that this server was the one that made so many connections?
    I checked alert.log, trc file and listener.log. What else can I check to determine what was the cause of this incident?

    user521219 wrote:
    Host SRVXXX is a server where a web app is and 192.168.1.1 is our firewall. May I think that this server was the one that made so many connections?
    I checked alert.log, trc file and listener.log. What else can I check to determine what was the cause of this incident?check IIS logs
    It could result from Denial of Service attack or trojan or virus infecting webserver

Maybe you are looking for

  • Getting the text from a text area

    I have a application and I wish to take in text typed in from the user into a textArea and then send it into a method however I need to be able to send this information to a static method which accesses a HashTable and then searches for the text inpu

  • Lumia 920: Still trying to figure out what the pro...

    Aside from being very upset about Nokia's not allowing updates for the unbranded 920s, I'm still trying to figure out what the problem is with my camera... I had nearly a perfect working phone one and a half week ago. Even though the battery didn't l

  • Inventory management configuration ?

    hii Can some body explain me about the configuration part for inventory management. Like Goods receipt Goods issue Transfer posting Physical inventory ......etc Explain me in short without any links ... Thanks

  • "Safari cannot open the page – 'too many redirects'"

    Problem iPad issue impacting our secure website clients. Error message reads "Safari cannot open the page – 'too many redirects'" History: Recently, some of our secure website clients using Mac/Safari 4.0.5 faced issues, all related to one common pro

  • Full Screen Application

    Hello, my problem is the following: I have this piece of code... JTabbedPane tabbedPane = new JTabbedPane(); JComponent panel1 = makeTextPanel("Panel #1"); tabbedPane.addTab("Tab 1", panel1); JComponent panel2 = makeTextPanel("Panel #2"); panel4.setP