Maximum safe fill for Raid-5 without hot spare?

What is the percentage of total capacity that can be used while still maintaining security blanket of the RAID-5 parity data?
I have two 7-drive arrays, neither include a spare, and simple logic suggests that the total data should not exceed the formatted capacity of six of the seven drives. Is it possible that six drives could manage, say, six-and-a-half drives worth of data via parity data, in the event the seventh drive fails?
Various G4   Mac OS X (10.4.8)  

In addition to William's comment re utilization, the maximum space you can get from a 7-disk RAID 5 volume is 6 drives-worth.
That is, seven 500GB drives results in 6 x 500GB usable space, or 3,000 GB. It is not possible to extend the usable space into the seventh drive.
In RAID 5, all data is spread across all drives in the array, so there isn't actually a spare drive, or a single parity drive. RAID 3 uses a separate parity disk, but even in that configuration you cannot use space on the parity drive as user data because it's little more than a 1:1 map of the blocks on the data drives - any data on the parity space is interpreted as the parity data for the corresponding blocks on the other drives. If you stored real data in that space it would totally hose the corresponding data on the user-space disks.

Similar Messages

  • Maximum safe voltage for onboard GPU (GT overclocking) on 2500k using Z68A-GD65?

    i am currently stuck on using onboard graphics of my 2500k which is HD 3000 until i wait for my new GPU to arrive(probably 2-3weeks from now  )
    i looked everywhere and can't find any answer on how high should be the limit for onboard GPU overclocking
    the option is from 1.0-1.35v
    how high is the safe limit for onboard gpu voltage so i could start pushing the chip ?

    Quote
    i looked everywhere and can't find any answer on how high should be the limit for onboard GPU overclocking
    Every place except the one it might be found? The Intel datasheet?

  • Replace Disk RAID 5 with hot spare disk form old disk

    i'm going to replace a failed disk form server Proliant SL360 G5 and using RAID 5 with a disk has been used from older server.
    my question is there any side effect in RAID 5 on server that has been replace from a failed disk with the old disk?

    Hello @Oktandri,
    I understand that you are replacing a failed disc on your Proliant Servier and are wondering if there are any side effects that you should be aware of. I am sorry, but to get your issue more exposure, I would suggest posting it in the commercial forums, since this is a commercial product. You can do this at HP Enterprise Business Community - Servers.
    I hope this helps. Thank you for posting on the HP Forums. Have a great day!
    Please click the "Thumbs Up" on the bottom right of this post to say thank you if you appreciate the support I provide!
    Also be sure to mark my post as “Accept as Solution" if you feel my post solved your issue, it will help others who face the same challenge find the same solution.
    Dunidar
    I work on behalf of HP
    Find out a bit more about me by checking out my profile!
    "Customers don’t expect you to be perfect. They do expect you to fix things when they go wrong." ~ Donald Porter

  • Can you run RAID 5 + Hot Spare on ix4-200d, or just RAID 5?

    Solved!
    Go to Solution.

    Hello trevorsem
    The ix4-200d would only be able to do RAID 5.  Hot spare would not be an option.  You could technically use only 3 disks in the RAID 5, but it would not be using the unit to it's best ability.
    PX class devices can use hot spares with RAID 1, 5, 6, and 10
    LenovoEMC Contact Information is region specific. Please select the correct link then access the Contact Us at the top right:
    US and Canada: https://lenovo-na-en.custhelp.com/
    Latin America and Mexico: https://lenovo-la-es.custhelp.com/
    EU: https://lenovo-eu-en.custhelp.com/
    India/Asia Pacific: https://lenovo-ap-en.custhelp.com/
    http://support.lenovoemc.com/

  • Px4-300r setup raid 5 + hot spare

    I bought a px4-300r NAS and in the spec I see it is possible to make a raid 5 with hot spare. I configured a raid 5 with 3 disk but I don't know how to set up the hot spare with drive 4 ?
    LenovoEMC™ px4-300r  
    Version : 4.0.6.19294
    BIOS : PX4 FSBFV102
    tks
    Solved!
    Go to Solution.

    Did you actually read the manual before posting this question?

  • Why is hot spare in use while disk state is Okay

    In my Solaris 10 RAID-5 volume, metastat shows the hot spare in use, but all the disks' state is Okay. Why is this? I do suspect the first disk was bad at one time, and may have been pulled out and re-inserted in without issuing any solaris commands. Please help explain why, and how to recover from this situation. Thanks.
    d10: RAID
    State: Okay
    Hot spare pool: hsp000
    Interlace: 32 blocks
    Size: 860024640 blocks (410 GB)
    Original device:
    Size: 860032704 blocks (410 GB)
    Device Start Block Dbase State Reloc Hot Spare
    /dev/dsk/c10t500000E01013A380d0s2 10506 No Okay Yes /dev/dsk/c10t20000004CFAA17C8d0s2
    /dev/dsk/c10t500000E01013A230d0s2 10506 No Okay Yes
    /dev/dsk/c10t500000E01012D7A0d0s2 10506 No Okay Yes
    /dev/dsk/c10t500000E010128CE0d0s2 10506 No Okay Yes
    /dev/dsk/c10t20000004CFC22131d0s2 10506 No Okay Yes
    /dev/dsk/c10t500000E01012D7B0d0s2 10506 No Okay Yes
    /dev/dsk/c10t20000004CFAF377Fd0s2 10506 No Okay Yes
    hsp000: 1 hot spare
    Device Status Length Reloc
    /dev/dsk/c10t20000004CFAA17C8d0s2 In use 143349312 blocks Yes
    Device Relocation Information:
    Device Reloc Device ID
    /dev/dsk/c10t500000E01013A800d0 Yes id1,ssd@n500000e01013a800
    /dev/dsk/c10t500000E01013A850d0 Yes id1,ssd@n500000e01013a850
    /dev/dsk/c10t500000E01013ABD0d0 Yes id1,ssd@n500000e01013abd0
    /dev/dsk/c10t500000E01013B270d0 Yes id1,ssd@n500000e01013b270
    /dev/dsk/c10t20000004CFAA17C8d0 Yes id1,ssd@n20000004cfaa17c8
    /dev/dsk/c10t500000E01013A380d0 Yes id1,ssd@n500000e01013a380
    /dev/dsk/c10t500000E01013A230d0 Yes id1,ssd@n500000e01013a230
    /dev/dsk/c10t500000E01012D7A0d0 Yes id1,ssd@n500000e01012d7a0
    /dev/dsk/c10t500000E010128CE0d0 Yes id1,ssd@n500000e010128ce0
    /dev/dsk/c10t20000004CFC22131d0 Yes id1,ssd@n20000004cfc22131
    /dev/dsk/c10t500000E01012D7B0d0 Yes id1,ssd@n500000e01012d7b0
    /dev/dsk/c10t20000004CFAF377Fd0 Yes id1,ssd@n20000004cfaf377f

    Thanks for the suggestion. Tried "metahs -e ...". "Hotspare isn't broken, can't enable".
    Tried "metareplace -e ...", "d10: device ... enabled" It's currently in sync'ing mode. I guess drive 380 was pulled out and reinserted at one point without issuing the metareplace command.
    Edited by: user8636975 on Nov 29, 2011 8:05 PM

  • Maximum HD size for MDD G4?

    Hi there
    I had a real pain in the proverbial when trying to do a clean install of Panther (or Tiger) on a 1Ghz G4 on a new 200 Gb HD. There were instablilities, Hands on shout down/restarts, etc, before running any updates or 3rd party apps.
    Is there a maximum HD size for these Macs? It came with a 80Gb HD.
    Thanks for any help...

    Some RAM that worked under prior versions of OS X has been known to fail. Tiger makes much more use of all available RAM for cache is part of the reason. Memtest would give it a good workout overnight.
    MDDs support Cable Select, it depends in part on the IDE cable itself. In fact, you could use it on older Macs and controllers most of the time.
    Never apply an update without first doing a backup and some disk repair and maintenance. Even flushing the cache folders with something like Applejack. Never use your Mac while an update is taking place. Reboot prior to applying an update, might want to use Safe Boot Mode. And use the standalone updates, and the combo update if possible. On some occasions it was necessary to reapply the combo update.
    With Tiger, I found that while it was possible to update, a full erase and install resulted in a better OS. So backup.
    If you keep your home directory or backup on another drive, so much the easier and better.

  • Raid- Understanding "Hot Spare" and Windows reinstall - Final Steps

    Hello all,
    If you follow couple of my other recent threads here you will see I have a warning of a failing drive in my 4 tb raid (4 x 1TB raid set.)
    Also for an unrelated reason I am also needing to reinstall Windows 7.  (and of course my Adobe Master collection CS5)
    I ordered a 5th drive to serve as "Hot Spare" and it will be arriving sometime today from Amazon.
    I want to make sure I do the above "final steps" properly, in the correct order.
    I am basing my "final steps" based on Harm's advice on another thread:
    >>>
    You can never be too safe with data, but if you follow the hot-spare,  extend raid set and rebuild sequence, it is not necessary. Your data  will be reconsructed automatically. That is the reason you use a  raid3/5.
    Your log file is a definite show of a serious  disk problem. Replace it, create a hot-spare, extend your raid set and  rebuild (it should be done automatically) and you are ready to roll
    >>>>
    (As a precaution I have done a backup of my raid, to an external drive)
    So once my new hard drive arrives today from Amazon, I will, in the following order:
    1)  Replace failing hard drive.  (Do I need to power down the computer to remove the failing hard drive and replace it with the hot spare?  Or can I leave the computer powered on so that the raid software can continue its CONSISTANCY CHECK while II do all of the steps to rebuild the raid  --- see note at bottom of this post...)
    2)  Create hot-spare
    3)  Use the Raid controller software (Areca) to EXTEND HOT SPARE
    4)  Rebuild raid (it should be done automatically)
    THEN, after I confirm that the raid is working okay, I will
    5)  Reinstall Windows 7.
    THe below step is what I am not entirely clear on:
    6)  I assume since the raid has already been rebuilt {before I did the windows 7 reinstall) I can do a very straightforward "reconnect" to the already working raid.  In other words, I would reinstall the Areca raid software (using the Areca cd) and identify the raid and windows 7 will recognize the 4 tb raid as my raid drive.
    I am tracking the delivery of my new hard drive and it is at least 5 or 6 hours away from arriving from Amazon.
    ****  CONSISTANCY NOTE: I the meantime I am having the Areca web based controller software do a CONSISTANCY check of the raid.
    It is half way through the check and has found 144 errors so far.   The consistancy check is rather vague about what it is doing.  But can I assume that it is finding the errors and will automatically fix them.
    Or do I have to do something to fix the errors once the consistancy check is finished (This is one reason why I would like to avoid powering down during the rebuilding of the raid.)  Or will creating the hot spare, etc interrupt the consistancy check, meaning I must finish the consistancy check completley before rebuilding the raid.
    Or should I abort the consistancy check and do that after I reinstall windows.  (If possible I would like to do that so I can get on with the editing of my current project!!)
    WHEW!
    Rowby
    Message was edited by: rowby

    WEB BROWSER-BASED CONFIGURATION
    132
    6.6.5 Check Volume Set
    To check a volume set from a RAID set:
    (1). Click on the “Check Volume Set” link.
    (2). Click on the volume set from the list that you wish to check.
    Tick on “Confirm The Operation” and click on the “Submit” button.
    Use this option to verify the correctness of the redundant data in
    a volume set. For example, in a system with dedicated parity, volume
    set check means computing the parity of the data disk drives
    and comparing the results to the contents of the dedicated parity
    disk drive. The checking percentage can also be viewed by clicking
    on “RAID Set Hierarchy” in the main menu.
    Directly from the Areca 1600 series Manual. I would let that finish.
    Eric
    ADK

  • HT201209 How can I create an apple ID for my daughter, without adding a credit card to the account?

    How can I create an apple ID for my daughter, without adding a credit card to the account? I have tried to purchase a gift card online, but it just credits it to my account; I cannot use it to credit her new account therefore I cannot create that account.

    There are intructions on this page for how to create a new account without giving credit card details : http://support.apple.com/kb/HT2534
    e.g. log out of your account, find a free a free app in the store, click on its free 'price' :
    click on 'create Apple id' on the popup :
    Agree to the terms and fill in the details, and you should get 'none' on the payments screen.

  • How can I tell if HD is set up for RAID?

    I received an external Western Digital 4TB drive with some files on it and I'm trying to tell if the drive is already set up for RAID or not. The company I received it from couldn't tell me and according to the WD box, it's "pre-configured for maximum capacity (RAID 0)". However, when I go into Disk Utility to view the drive, it says the capacity is only 1.8T.
    I little more detail... In Disk Utility the left window shows the drive named, "1.8 TB WD My Book Media". Total capacity 1.8TB
    S.M.A.R.T. Status: Not Supported
    Partition Map Scheme: GUID Partition Table
    ...In the Partition window it looks like a single partition. Again, Size: 1.8 TB, Available space: 1.1 TB.
    Does this make sense? Sorry, I'm not familiar with RAID drives and how they're set up and used. Any help with this would be greatly appreciated.
    I'm just trying to find if this drive is in fact set up as a RAID drive and if so, is it mirroring to the second drive in the enclosure? or not? And if not why does it say that the drive is only 1.8 TB?
    Sorry for the rambling.
    Thanks.

    There is no such thing as a "RAID" drive. Any drive can be used in a RAID array. A single drive is not a RAID drive. It is simply a single drive. When multiple drives are combined into an array via software and/or hardware then one has a RAID array.
    Now as far as I can determine WD does not make a single drive larger than 2 TBs. Formatted the drives will contain roughly 1.8 TBs. WD does make a My Book version that has two 2 TB drives that can be configured into a striped RAID array that will provide 4 TBs of storage. I don't know if the product is pre-configured as a RAID array or if you must configure it as such using Disk Utility. For the latter you must first partition and format each drive then use the RAID tab option of DU to set up the RAID array. Select Disk Utility Help from the DU Help menu and search for "raid" to get the help articles on how to set up striped or mirrored RAIDs.

  • Maximum file size for export into MP4?

    Hello,
    I am not able to export 2 hour HD video into standard MP4 file. It seems that reaching 100% export algorithm gets into loop. I was waiting for hours and still had seen progress at exactly 100% with final file size on hard disk to be 0 bytes. I am using CS5 on MAC OS X. I had to split my timeline to 2 parts and to export them separately (which is embarrasing). Is there something like maximum file size for export? I guess that 2h video would have about 25-35GB.
    Thank you
    jiri

    You are right.
    So I am running AP Pro 5.0.4, Adobe Media Encoder 5.0.1.0 (64bit). Operating system Mac OS X ver 10.7.3. All applications are up to date.
    MacBook Pro Intel i5 2.53GB, 8GB RAM, nVidia GT 330M 256 MB, 500GB HDD
    Video is 1920x1080 (AVCHD) 25fps in a .MTS container  (major part of timeline), 1280x720 30fps in .MOV container (2mins), Still images 4000x3000 in .JPG
    No error message is generated during export - everything finishes without any problem...just file created has 0 byte size (as described above).
    This is my largest video project (1h 54min) I dont have any other problem with other projects.
    I dont run any other special software, at the moment of export all usual applications are closed so that MacBook "power" can go to Media Encoder. No codecs installed, using VLC Player or Quick Time.
    Attached please find printscreen from Export settings (AP Pro). Writing this ppost I tried to export only the first 4mins from timeline where all kind of media is used...and it was OK.
    As a next step I will try to export (same settings) 1h 30mins as I still believe problem comes with length of video exported.
    Let me know your opinion

  • Maximum cable lengths for USB / FW / DVI & sVGA?

    I've hunted around on the net and can't find any kind of definitive answer regarding maximum cable lengths for USB, Firewire 400/800 and DVI / sVGA monitors. Can anyone shed some light?
    I'm about to shift my studio into a new room, and have the oppourtunity to stick my G5 and external drives into a corridor cupboard adjacent to where my studio is - in other words, noise free bliss! But....
    ...if I map out how far my computer monitors, keyboard and audio interface will be from the cupboard, and take into account the twists and turns involved in neat routing, I'm looking at a distance of about 10 meters. I need to know if any of these devices will be OK with such a long run of cable, and if not, if it's possible to achieve a good result using hubs or repeaters?
    So, can anyone help me out with info on:
    an Apogee Ensemble (Firewire 400)
    an Apple keyboard (USB 2.0)
    an LCD flatscreen (DVI)
    and another LCD flatscreen (sVGA)
    Many thanks!

    I was just researching the very same thing, though it does not  sound like my studio setup will be as sweet as yours. Here are a few things I ran across:
    FIREWIRE-
    "The maximum cable length specified by the IEEE1394 standard is 4.5 meters. However, more recent tests have shown that certain high quality firewire cables can achieve longer lengths without significantly affecting transmission quality. Several manufacturers sell firewire cables longer than 5 meters (some up to 50 meters)."
    ~http://www.focusrite.com/answerbase/article.php?id=206
    I found an example of a company who claims to sell a firewire cable of that length:
    http://www.expansys.com/pf.aspx?i=102956
    USB-
    There is forum discussion on the topic I was reading yesterday:
    http://www.everythingusb.com/forums/showthread.php?threadid=804
    But don't go past the 11th post or so, they go off on another subject... the use of hubs & the words "active extension" in that post caught my eye. A quick google search came up with this site:
    http://www.everythingusb.com/forums/showthread.php?threadid=804
    There were a bunch sites with devices claiming to do this.
    Finally I have this chart, which seems to support what what the articles say, without of course any other extension technology/solutions:
    http://www.extron.com/company/article.aspx?id=dedigform10
    I'm not making any claims at all about how true these sources are, I just have the same questions and decided to toss what I've been looking at into the discussion. Feel free anyone to jump in and tell me its all wrong - I'd love to hear whats right.
    ~sam

  • Is it safe to use iphone 4 without a case

    Is it safe to use iphone 4 without a case

    I was using it with case for 2 years. Now I've taken it off and have it without for about a month. I just bought a skin protector so nothing's gonna scratch my iPhone.

  • Replace the Hot Spare that Shared between Raid 1 and raid 5

    I have ProLiant ML370 G6  with Smart Array P410i Controller on System Board 
    I have two Logical Drive (Logical Drive 1 - Mirroring (RAID 1) And (Logical Drive 2 - Distributed Data Guarding (RAID 5)
    The logical Drive 1- Mirroring (RAID 1) Have two Physical Drives 
    The Logical Drive 2 Distributed Data Guarding (RAID 5 Have three Physical Drives
    And There Are One Spare Drive Shared btween RAID 1 and Raid 5 
    Controller Configuration Summary
    2 Data Array(s)
    2 Data Logical Drive(s)
    5 Data Drive(s)
    1 Spare Drive(s)
    The problem :
    there are that the spare Drive FAil and have warining To replace it 
    I  replace this drive with new one but the repulid for the Drive not start and Give Inactive 
    How Repulid the Hot Spare drive  ?

    Hello Amostafa,
    Welcome to the HP Forums, I hope you enjoy your experience! To help you get the most out of the HP Forums I would like to direct your attention to the HP Forums Guide First Time Here? Learn How to Post and More.
    I understand that you are looking to rebuild the hot spare drive on your ProLiant system, and I would be happy to guide you towards a resolution!
    I am sorry, but to get your issue more exposure, I would suggest posting it in the commercial forums, since this is a commercial product. You can do this at:   
    http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/bd-p/itrc-264
    I hope this helps!
    Regards
    MechPilot
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the right to say “Thanks” for helping!

  • Undestanding the OSM-AIA integration with SAF agent for RODOD 11gr2.

    Hello all,
    As we don't yet manage the sending of sales orders from AIA 11.1 to OSM 7.2, I looking for some information about the way AIA and OSM may be integrated with SAF agents.
    During the installation of the O2A cartridges in Design Studio, the SAF agent has been choosed against the JMS bridge approach.
    So in OSM's WebLogic domain,
    - a SAF agent is created
    - JMS resources are created in the oms module:
    -      a Remote SAF Context describing the way to be connected to the AIA's weblogic instance
    - the remote imported destintations i.e.:
    AIA_CRTBO_OUT_JMSQ
         AIA_CRTCUST_OUT_JMSQ
         AIA_CRTFO_OUT_JMSQ
         AIA_CRTTTREQ_JMSQ
         AIA_FOPROV_OUT_JMSQ
         AIA_LFERROR_JMSQ
         AIA_UPDSO_OUT_JMSQ
         AIA_UPDTTREQ_JMSQ
    Sending an order from Siebel to AIA fills an AIA_FOPROV_IN_JMSQ on the AIA database which seems to be not consumed because on the OSM side, no order is ssen in the oms_ws_requests queue.
    So, we are wondering if the Order to cash PIP in AIA is incomplete or not. Should be a SAF-agent in AIA to send orders to OSM? Should we complete the current SAF-Agent in OSM to receive and send messages to AIA?
    To integrate ASAP or UIM to OSM, it is recommended to define a SAF-Agent in OSM to send messages and a SAF-Agent in ASAP/UIM to reply to OSM. It lets me think that our AIA installation is incomplete.
    On the other side, when JMS bridges are used in OSM in 7.0.2, a bridge called created AIA_2_CFS_CreateOrder_is defined to locate and consume the remote JMS queue AIA_CRTFO_IN.
    In conclusion, we'd like some explanations on the way to integrate as well as possible AIA and OSM in a SAF context. It will help use quite a lot.
    Many thinks in advances.
    Regards,
    Christophe.

    Hi
    On OSM side should exist SAF agent for sending messages to AIA queue's and same on AIA side for sending to OSM queue's. You can even combine SAF agaent on one direction and bridge's in another direction but you'll have to do it manually in that case.
    If you see message in AIA queue and not forwarding to OSM I would first check SAF agent on AIA side ( usr/pass + remote destination (OSM) )
    best regards
    Tomac

Maybe you are looking for

  • How to disable the EO cache in AM ?

    My customer share AM defination codes between two applications,and let EO coexist in multi AMs.And they have build a lot of codes.I wonder if this will exist trouble. from the support documents, I know the AM has an EO cache. after one client update

  • Need help on setting large fonts on iphone 3g s

    I have looked at the new iphone 3g s, and think I would like it very muuch. However, since I am somewhat visually impaired, I need large fonts on ALL categories on the phone, e-mail, contacts, notes, etc. I have looked at the phone at my local Apple

  • How do I make Google go away as my browser and restore my old browser?

    I hate the browser that Adobe downloaded.  I lost access to so many things of value to me. 

  • Export shared service active users (provision for Hyperion)only using MSAD.

    Hi.. I m using Hyperion 9.x . and using active directory in shared services. while i m using importexport utility to export the active users list with provisioning. Issue is : Hyperion external authentication have all users of Active directory but i

  • Itunes Screensaver just displays black screen