Message no.8Z876 No time base defined for the revaluation key -Problem ABAW

Hello,
I have a problem... I have a revaluation area (04: in local currency) and a parallel revaluation area (05: in hard currency) and I have to revaluate an asset, but I couldn't with Tx ABAW. The error is :
Message no. 8Z876 No time base defined for the revaluation key
I checked the configuration and I think it's all ok. I did some tests and I could revaluate only the Area 04 (local currency). Example:
Area 04: 500000 PEN
Area 05: 0 USD.
But this is a big problem for example when I make a transfer the asset to other because the revaluation Area doesn't transfer.
Can anybody please tell me how resolve this?
Regards,
Fernando
PD: I'm so sorry for my grammatical errors, I'm spanish speaker

Hi
The error
message 8Z 876 can be shown for two basic things:
1. TBE (Time Base exposure variant) is not maintained.
   Please check if any time base is maintained for the revaluation key.
And if it have all the intervals correctly defined and the post flag
marked for the months required to calculate revalaution.
   If it is maintained please check if the last revaluation date is
filled in your revaluation areas. If the last revaluation date field is
blank, the time base must have the following entry: 31.12.XXXX-1 where
XXXX is the current fiscal year (for ABAW).
2. In the ABAW transaction itself you are trying to post values to any
of the parallel areas defined in the chart of depreciation.
   In transaction ABAW (or AB01) do not post any amount to parallel
areas. The posted values should be equal to zero.
   The values in hard currency will never be revaluated by the inflation
program. If this is the case, please enter manually only zero values as
"Amount posted" in those parallel areas.
If by some specific reasons you still plan to post (manually) to these
parallel areas, you will get error message 8z876 in accordance to your
explanation of the problem.
   To allow posting of non-zero amounts to these areas, you need to
create Revaluation Key NULO. To do this, go to the customizing system
IMG (transaction SPRO) according to the link:
IMG -> Financial Accounting -> Asset Accounting -> Special Valuation ->
        Revaluation of Fixed Assets -> Revaluation for the Balance Sheet
        -> Inflation -> Maintain Revaluation Keys
Create new entry (click F5) for key with name NULO, And save data
(Ctrl+S).
  Please, adjust your customizing in accordance with the instructions
above.
Best Regards,
Blaz

Similar Messages

  • Exception: non-read-only mapping defined for the primary key field

    Hello.
    I'm new to Oracle and I created Java EE Web Project.
    And I created entities from tableA, tableB, tableC from my database.
    tableA has foreign key to tableB and has unidirectional Many-to-One relationship. tableC has two primary keys and one of these is foreign key to primary key in tableA. tableC also has unidirection Many-to-One relationship to tableA.
    Then I created session bean and data control from it, in design window, created read-only table from tableA.
    And I selected columns in tableA and also in tableB.
    I ran the application and saw the following exception in log window.
    Local Exception Stack:
    Exception [EclipseLink-46] (Eclipse Persistence Services - 2.1.3.v20110304-r9073): org.eclipse.persistence.exceptions.DescriptorException
    Exception Description: There should be one non-read-only mapping defined for the primary key field [tableC.tableA_ID].
    Descriptor: RelationalDescriptor(mypack.tableC --> [DatabaseTable(tableC)])
    tableA_ID is a primary key in tableA.
    How can I solve this error?
    Please help me.
    Edited by: 900471 on 2011. 12. 3 오전 5:32
    Edited by: 900471 on 2011. 12. 3 오전 5:33
    Edited by: 900471 on 2011. 12. 3 오전 5:33
    Edited by: 900471 on 2011. 12. 3 오전 5:34

    There are not enough details to be sure since you have not provided the mappings. From just the error, it looks like you are using the tableC.tableA_ID field as the foreign key in the ManyToOne relationship to A, but have marked it as insertable=false, writeable=false, meaning that it cannot be updated or used for inserts.
    Either make it writable (set the settings to true), or add another basic mapping/attribute in the entity for TableC that maps to the field which you can use to set when you insert a new tableC entity. A simple example is available at
    http://wiki.eclipse.org/EclipseLink/Examples/JPA/2.0/DerivedIdentifiers
    Best Regards,
    Chris

  • Warning: "No terminating events defined for the task used"

    Dear all,
    I created a task with ABAP class and method as its object method. This task is a background task. The ABAP class inherits the IF_WORKFLOW interface but doesn't implement any method of the interface.
    When I try to confirm the task settings in transaction SWDD, a message shows up "No terminating events defined for the task used" and I cannot continue the work. Does anybody have any idea what I should do?
    Thanks + Best Regards
    Jerome

    Hi Jerome,
    If you set a background task in your workflow, and if it is asynchronous, then you need some way to tell the template if it is finished and what happened.  In this case you set terminating events - that is events which are published in the system as a result of your method (ie document.posted etc).
    Either use a synchronous method for your task or set appropriate terminating events in your task setup.
    Regards
    Gareth

  • ERROR - 1023001 - No matching region defined for the specified server,app,

    Gurus,
    I was trying to sync two cubes, basically one has to go to the other.
    This is the script
    refresh replicated partition 'app2'.'db2' from 'app1'.'db1' at $COMPUTERNAME all data;
    However, when I check the logs, I get this error message
    ERROR - 1023001 - No matching region defined for the specified server,app,db:
    How do we fix this error. When I checked some of the essbase erro docs, I dont find it.
    Please help
    Thanks

    Do you get any additional information in your app log?If so, can you post the message.We run on UNIX (solaris) here and ran into an issue with host-name resolution that turned out to be hostname cache problem. I don't know if you have similar on AIX.

  • EHSM - Create Vendor - error: 'Could not find a document for the given key'

    Dear all,
    In the Chemical Approval Process I have attached a SDS document to the Approval Request. You can assign a Vendor to the SDS. As there are no (EHSM) Vendors currently available in the system I would like to create a new (EHSM) Vendor by clicking on 'Create Vendor'.
    This will lead me to the following Webdynpro Application: Edit Vendor (EHFND_UI_VENDOR_OVP).
    Only one field is shown in the Webdynpro named: 'Name of the Vendor'. After typing a name e.g. 'test', the following error message appears; 'Could not find a document for the given key'. See also attached document. This issue looks like a missing number range, however I could not find a EHSM number range for Vendors.
    How to solve this issue?
    More information:
    Software Component: SAP EHS Management (EHSM) Support Package: 3
    Process: Chemical Approval
    Webdynpro application: EHFND_UI_VENDOR_OVP
    Thank you.
    Kind regards,
    Roy

    Hi
    babooraj
    This might be a problem with Windows Power Shell.
    The solution is to copy the folder: "PSWorkflow" from "C:\Windows\System32\WindowsPowerShell\v1.0\Modules\"
    to "C:\Windows\SysWOW64\WindowsPowerShell\v1.0\Modules"
    Than everything works fine.
    Ps.: @Microsoft, please fix this problem in future versions.
    Thomas van Veen

  • I have an Airport Extreme Base Station and have recently upgraded to Mountain Lion. Now airport utility won't work with my base station so I bought a Time Capsule. For the life of me I can't make the substitution work and only see a blinking amber light.

    I have an Airport Extreme Base Station and have recently upgraded to Mountain Lion. Now airport utility won't work with my base station so I bought a Time Capsule. For the life of me I can't make the substitution work and only see a blinking amber light. Can anyone who has made this change offer some advice?

    apikoros wrote:
    The Utility transferred all of the AE's settings, so I still have to change the password, which leaves me with only 2 other questions, I think:
    1)  I assume it's just a matter of using the Utility, entering a stronger password and checking for it to be remembered in Keychain Access.  But do I have to  change the password for each individual unit-- the TC, the Extreme and both Expresses-- or will changing it just for the TC alone work for the entire network?
    Resetting the password you will need to do for each device... the utility cannot even see those old units.
    So you will have to do it for each one.. think it through.. because as you change passwords the others will lose connection.. so start from the express which are wireless extending .. change those first.. and go back up the chain.. as each one changes it will drop off the network.. until you reach extreme and change that. Then you might need to reboot the whole network to get everything talking again. If something goes wrong.. just pluck that one out of the mix and plug in ethernet.. reset and redo the setup. That is my preferred method anyway.. do everything in isolation one by one. By ethernet and then nothing goes wrong.
    2)  Who's the treasonous SOB who spilled the beans to you about the ICBM in my back yard?!?
    N.Korean hackers.
    [Edit] Whoops-- one more question:  I want to partition the TC's disk, but Disk Utility doesn't see it.  What do I need to do?
    You cannot partition a network disk. And apple provided no tools for it in the TC itself. You can pull the disk out and partition it but that voids your warranty. (although done with care who is to know).
    Look at Q3 here.
    http://pondini.org/TM/Time_Capsule.html
    Mixing TM and data on the TC is worth planning carefully. They don't necessarily sit happily together.

  • Message FZ626 -Payment orders are not defined for extended withholding tax

    Hi Gurus,
    Would you please help me with the message below:
    Message FZ626 -Payment orders are not defined for extended withholding tax
    In my company  payment orders are created in F110  for accounts payable, as we use another ERP system (Baan) to perform the local accounts payments, and now I've just activated Extended withholding tax functionality With accumulation (necessary in Brazil) but I get this error.
    Is it not possible to user payment order with extended withholding tax + accumulation? I find it hard to believe...
    I've tried to unflag the payment order only for the payment method I'm using in FBZP t.code, but then no payment order were created but instead a payment document were posted with the withholding tax accumulation, but this is not the way we are working, and nothing is sent to Baan
    any help is welcome !
    TREAD LOCKED SINCE IT IS DUPLICATED FROM THREAD payment order are not defined for extended withholding  tax

    Hi,
    On the analysis,  the system expects an entry in the T059Q table with
    code as XX.
    The reason being in the extended withholding tax we use multiple
    witholding tax codes and these entries are stored in the table
    with_item. And in BSEG we populate the field withholding tax code i.e.
    BSEG-QSSKZ  with the value 'XX'. In classical withholding tax we used to
    store the code directly which is not possible with Extended withholding
    tax.
    As the field BSEG-QSSKZ refers to the values in the table T059Q-QSSKZ
    the entry 'XX" needed in this table for the corresponding country of the
    company code to maintain the correct relationship and consistent
    database information.
    Hence for the statistical purpose and for the internal calculations we
    need an entry in the table T059Q. Could you please maintain this code
    i.e. 'XX' also in the table T059Q in a test system? Then retest your issue.
    This should resolve your issue.
    Kind Regards,
    Vanessa.

  • I've lost a load of notes, but dont know why or how to get them back. I cant find the folder that is in my Yahoo account that people have suggested might be the location for the messages.  I recently signed into iCloud for the first time.

    I've lost a load of notes, but dont know why or how to get them back. I cant find the folder that is in my Yahoo account that people have suggested might be the location for the messages.  I recently signed into iCloud for the first time.  Any idea how to get the notes back?   I really dont want to lose them.

    It should keep asking for the password, because it's trying to check for purchases... As soon as you login, it will see you have pending downloads and create the downloads section on the left below Purchases under the Store section. Then it will start the music downloads there, as they will be listed one below the other.
    You could just try to check your account balance or view your account and that will trigger a password request too. You can just click on that and say that now iTunes keeps asking for the password and ask him to help you with that. Trick would be to interrupt him so that he carries on with another task after, so he doesn't notice the download. Or you carry on with email or browsing which you were "busy" with when iTunes interrupted you for the password (stupid iTunes)

  • Sequence No. not defined for the location [Message 80072-11]

    Dear Friends,
         I have setup sequence for A/R Invoice, Incoming / Outgoing Payment and Excise Register, and created a few document successfully (with sequence number). But when I go to u201CTax Payment wizardu201D, in the 2nd stage on selection of any location give the following error and even the u201CSeq. Nameu201D does not show any sequence name.
    u201CSequence No. not defined for the location [Message 80072-11]u201D
         Can any one please tell me the reason behind for SAP B1 2007B SP0 PL7?

    Hi Narottam,
    Check this link
    Sequence Series
    Regards
    Jambulingam.P

  • HT1918 Trying to edit my payment info.  I keep getting the message that my number is not valid for the type of card I have selected.  I have a VISA card.  I have typed in the number 4 times, but same message pops up.

    Trying to edit my payment info.  I keep getting the message that my number is not valid for the type of card I have selected.  I have a VISA card.  I have typed in the number 4 times, but same message pops up.
    Thoughts?

    You are probably entering your Visa's security code incorrectly.  Here's how to find it:
    http://support.apple.com/kb/HT3541

  • "Quicktime not installed on this system" message when starting up AE CC 2014 for the first time...

    Got a "Quicktime not installed on this system some functions disabled" -- or something to that effect -- message when starting up AE CC 2014 for the first time.
    I'm on a Mac Pro OS 10.9.3.
    Anyone know what I need to install to fix this?  I have the Quicktime player and QT plugins for browser, etc...  Never had to do anything for AE before.
    Thanks!

    solutions for problems with QuickTime files in After Effects CC (12.0) because of conflict with DVCPROHDVideoOutput Quic…

  • SFLIGHT is NOT defined for the current logical database.

    I have just started learning ABAP and bought an ABAP Objects book by Horst Keller. I have installed 4.6d mini sap and SAP GUI 6.4 on win XP Prof. I executed S_FLIGHT_MODEL_DATA_GENERATOR to load DB tables.
    (1). When I tried to check a sample program, I get an error message SFLIGHT is not defined for the current logical database.
    Here is the partial code:
    REPORT zbcb01f1 .
    TABLES: sflight, sbook.
    DATA: BEGIN OF sr OCCURS 100,
          carrid LIKE sbook-carrid,
          connid LIKE sbook-connid,
          fldate LIKE sbook-fldate,
          bookid LIKE sbook-bookid,
          order_date LIKE sbook-order_date,
          loccuram LIKE sbook-loccuram,
          END OF sr.
    GET sflight.   <---- Error is pointed here
    (2). I am also not getting Graphical Screen Painter when selecting Layout for a screen. Instead, I am getting alphanumeric editor.
    Someone please help me.  
    Raizak.

    Hi Raizak,
    the easiest way is to go to service.sap.com/notes and enter the note number. For this time I've copied the 2 notes below.
    Best regards,
    Christian
    Symptom
    The Graphical Layout Editor of the Screen Painter either does not start or terminates.Error message 37527 is displayed in the session in which the call was made (Graphical Layout Editor not available.
    Additional key words
    () EUNOTE, EUSCREENPAINTER, 37 527
    Cause and prerequisites
    This note comprises all the common causes for error message 37527 and provides you with information on how to systematically trouble shoot the problem.
    1. Windows32 or UNIX/motif?
    As of Release 4.6B there is only the program version for 32bit Windows (NT, 95, 98, 2000 ff.).Up to Release 4.6A there was also a version for UNIX/Motif.All of the more current notes (with the exception of Note 45490) refer only to the Windows version.
    2. Termination at the start or during use?
    The following diagnostic steps refer to the causes of the errors which prevent the Graphical Layout Editor from starting. However, there are also known error causes, which result in the program terminating when the application is being used and which also produce the 37527 error message. This affects -
    Rel.4.6C/D: Termination when attempting to read texts in the logon language -> Note 375494
    Crash after transferring program and dictionary fields. Termination after transferring program and dictionary fields -> Note 189245
    Release 3.1I: Termination after inputting field text -> Note 113318
    3. Is the SAPGUI installation correct?
    The Graphical Layout Editor is automatically installed during the standard installation of the SAPGUI.If you chose a non-standard installation, then you should have explicitely selected its installation (component "Development Tools - Graphical Screen Painter").
    The program executable is called gneux.exe.During the SAPGUI installation it is placed in the same directory as the SAPGUI programms (for example, front.exe) (usually C:\Program Files\SAPpc\sapgui). The following belong to the program:
    - An additonal executable gnetx.exe (RFC starter program)
    - the DLL eumfcdll.dll
    - various eusp* data files (that is, the names all begin with eusp.)
    You can check the completeness of the program installation by starting the program gneux.exe locally in the SAPGUI directory (for example, by double-clicking on the program name in the Explorer window).The Layout Editor is displayed with German texts and an empty drawing area for the pseudo screen EUSPDYND 0000.
    If the installation is not complete, an error dialog box provides information regarding the cause of the error, for example, sometimes the DLL eumfcdll.dll is missing after reinstalling the SAPGUI. For example, the eumfcdll.dll DLL was sometimes missing after the SAPGUI was reinstalled.
    4. System link defined and okay?
    The Graphical Layout Editor is a separate program which is started by the Screen Painter Transaction (SE51) on the Frontend machine.
    Up to Release 3.0F, the programs communicated with each other via the graphics log of the SAPGUIs (gmux).The definition of the environment variable SAPGRAPH may be the cause for the program not being being found where it is.
    As of Release 3.1 G, the programs use a separate RFC link which is set up in addition to the SAPGUI's RFC link.Missing or incorrect definitions of the RFC destination EU_SCRP_WN32 or problems with the creation of the RFC link are the most frequent causes for error message 37527 being displayed.Below you can find the correct settings for the RFC destination EU_SCRP_WN32 (under "Solution").Note 101971 lists all the possible causes for problems with the RFC link set-up. Attention:The Graphical Layout Editor may not be operated through a firewall (for example between the SAP and the customer system) because this does not allow an additional RFC connection in addition to the SAPGUI.
    Solution
    ad 1 UNIX/Motif
    Note 45490 describes possible errors resulting from an incorrect program installation under UNIX/Motif (up to Release 4.6A).
    ad 2 Termination when using
    The above-mentioned notes may contain options for solving individual problems.However, you usually have to replace the program with an corrected version.You can do this either by downloading a patch from sapservX or by installing a more current SAPGUI.The patch is mentioned in the respective note.
    ad 3 Installation
    You either need to reinstall the SAPGUI or manually copy the missing file into the SAPGUI directory.In both cases you should make sure beforehand that a Graphical Layout Editor is no longer running.To do this you can either remove all processes gneux.exe from the process list by using a tool such as Task Manager (on WindowsNT) or exit the Graphical Layout Editor from the Screen Painter Transaction menu via Edit -> Cancel Graphical Screen Painter). Attention:For each session or system an individial Layout Editor process may exist so that, if need be, several processes should be cancelled.
    ad 4 System link
    Up to Release 3.0F:you can either delete the environment variable SAPGRAPH or copy all the files of the Graphical Layout Editor into the directory which is specified by SAPGRAPH.
    As of Release 3.1G:you can use Transaction SM59 to check the RFC destination EU_SCRP_WN32 (expand the TCP/IP connections, select destination EU_SCRP_WN32).If the destination is missing, then you should create it with the following settings:
    - Connection type "T" (start of an external program via ...)
    - Activation type "Start"
    - Start on "Front-end workstation"
    - Front-end workstation program "gnetx.exe" (caution! NOT gneux.exe)
    - Description (optional) "Graph. Screen Painter (Windows32)
      Start Program gneux.exe using the gnetx.exe starter program."
    If you want to start the program from a different directory than the SAPGUI standard directory, then replace the default value under Frontend work station by the complete path name for program gnetx.exe.Transaction SM59 also allows you to check the RFC connection via the pushbutton "Test connection").In this case the system attempts to localize and start the program gnetx.exe.If there are errors, a message is displayed regarding the possible causes (for example, gateway problem, timeout problem or the like).Note 101971 provides a detailed explanation of the problems involved with an RFC connection set-up.As the Graphical Screen Painter requires a functional RFC connection as of Release 3.1G, contact the System Administrator or create an message on the topic Middleware (BC-MID-RFC) if you encounter RFC problems.
    If the program gnetx.exe can be found and started, the banner dialog box with logo, release data and version number is displayed briefly.As the Layout Editor itself is not started, the error cause must be in the installation of the Layout Editor program gneux.exe if the connection test was successful.
    Release 4.5A to 4.6B: Use with Releases <3.1G>.
    The Graphical Layout Editor is downward-compatible as regards the system connection, that is, an RFC-based Layout Editor for example from Release 4.6C can also be used on a non-RFC-based Screen Painter, for example of Release 3.0F.However, the releases mentioned above have a program error which causes a crash due to memory violation in the start phase of the program.Note 197328 describes the solution by installation of the corrected program version.
    Important: Trace file dev_euspNNN!
    If none of the diagnosis steps leads to the cause of the error and to the solution of the problem via the corresponding note, then you should add the contents of the trace files dev_euspNNN (NNN = process number) to the message for SAP, if possible.You can find this file in the current directory of the SAP System, for example under Windows NT in C:\Winnt\Profiles\<user>\SAPworkdir.If several such trace files can be found there, make sure that you use the file which matches the termination time with respect to date and time of creation.In most cases the ERROR message in the last lines of this trace file provides an important note on the cause of the error.
    Source code corrections
    Symptom
    The graphic layout editor of the Screen Painter cannot be started (RFC version).
    Other terms
    () EUNOTE, EUSCREENPAINTER
    Reason and Prerequisites
    This is generally caused by the fact that the RFC connection between the frontend graphics layout editor and the calling screen painter program at the backend cannot be set up.
    Possibility 1: Route permission denied
    In the trace file dev_eusp<Process Id> of the graphics layout editor you find the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR route permission denied (<Front-Id> to <BackId>,<Service>)".
    If there is a firewall between frontend computer and application
    server, you need to decide whether the port for the RFC of the graphical layout editor can be released here (see Solution 1 below).
    In case no firewall exists between the frontend computer and the application server, in its route permission table, the SAProuter contains either no entry for the frontend computer, on which the graphics layout editor is started, or the entry says that the link is saved by a password.Since the connection is denied, the graphics editor processes exits again, and the screen painter switches to the alphanumeric layout editor.
    Possibility 2: Service 'sapgw<ServiceId>' unknown
    In the trace file dev_eusp<ProzessId> of the graphics layout editor you have the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR service 'sapgw<ServiceId>' unknown".
    The service sapgw<ServiceId> (for example, sapgw00) is not known on one of the computers participating in the RFC communication because the corresponding entry is missing in its service file. The affected computer can be the frontend computer or the gateway computer.
    Possibility 3: The system parameter gw/cpic_timeout value is too low
    This system parameter determines how many seconds the gateway is waiting for the RFC connection to be set up.In case of a high network load, the default value of 20 seconds is too small with the result that the connection cannot be created on time.Here the graphics layout editor process also exits with the trace file entry "ERROR in RFCMgr_accept: not accepted".
    Possibility 4: System parameter abap/no_sapgui_rfc set
    The profile parameter abap/no_sapgui_rfc of the system is set (that is, it has a value not equal to space or 0).This prevents the program of the graphics layout editor from being started with RFC at the frontend.
    Possibility 5: Unnecessary authorization check
    The error message "No RFC authorization for user xxxxxx" is generated although the check of the RFC authorization was deactivated by profile parameter auth/rfc_authority_check (value = space or 0). The problem is caused by a program error, that ignores the value of the profile parameter let during the call of the RFC authorization check (see Note 93254). This error can occur as of Release 4.5.
    Solution
    ad 1) If a Firewall is installed between frontend computer and the application server, you need to decide whether the port for the RFC link of the graphical layout editor shall be released in the firewall. This is port 33nn, where nn is the 2-digit system number of the SAP application server. As of Release 3.1G, the graphical layout editor needs an RFC link for communication with the application server in addition to the already existing linkof the SAP GUIs. Such a second link is not allowed by the firewall in general because it would contradict the security concept (password protection, logging of the connection).
    If no firewall exists, you should check whether the frontend computer can be added to the route permission table or whether the password option can be removed from out of the available entry.
    For details refer to chapter 4.4 of the attached Note 30289.
    ad 2) Include service sapgw<ServiceId> in the service file.
    Refer to Note 52959 for details.
    ad 3) Increase value for system parameter gw/cpic_timeout. 60 seconds should be sufficent as a timeout limit.
    ad 4) Set the system parameter abap/no_sapgui_rfc to space or 0
    Start the application server so that the new parameter value comes into effect.
    ad 5) Import the Support Package specified in the attachment for the release in question or implement the advance correction in the source code as described in the attached correction instructions.
    As a workaround, assign RFC authorizations as described in Note 93254.

  • Err in PO creation-Sales document item is not defined for the transaction

    Hi,
    I am getting the following error while creating PO
    "Sales document item 30000183 000100 is not defined for the transaction
    Message no. V1 198
    Diagnosis
    You have tried to carry out a business transaction for this sales and distribution document item which, for this item, is not allowed.
    This may be due to the fact that this item is not part of a make-to-order production with cost management in the sales order."
    I have used an item category which is copy of TAB and the sales order line item is attached to WBS element.
    can any one guide me what needs to be done.
    thanks

    If you want the sales order creation to initiate a PO creation automatically, check if the "Create PO Automatically" button is ticked on for the item category in Transaction flow tab in tcode VOV7
    This will solve your problem, provided your configuration for PO on the MM side is fine.
    Reward if this helps.

  • Problem Instanciating BO - No default attribute defined for the object type

    Hello Experts,
    I am instanciating the BO BUS2038 to ZBUS2038 and when I click in u201Cto implementedu201D and follow u201Cto releasedu201D the message No default attribute defined for the object type is appearing!
    Can anybody help, please?

    Hello everyone,
    it appears to me, that no one has a clue about the "default attribute" and is widely guessing what can be done about that.
    I feel deeply sorry for that, Marcos.
    At first: You don't really need to care about the missing default attribute. If it's missing, the object's instance key will be used instead. Skip the warning message.
    Secondly: The default attribute is used to display the instance within the "Object links & Attachments" under the work item preview when using the SAP Business Workflow.
    Thirdly: You can select any existing attribute of your business object type to be the default attribute, by navigating to the "Basic data" (it's the heat-icon within the object builder), use tab "Defaults" and use the Input Help on the field "Attribute".
    There you'll go.
    Best wishes,
    Florin

  • I just installed Airport Extreme. It works as a wireless network on my Macbook. It won't connect with my Windows Visa PC. Message reads: "settings saved on this computer for the network don't match requirements of the network.

    I just installed Airport Extreme. It works as a wireless network on my Macbook. It won't connect with my Windows Visa PC. Message reads: "settings saved on this computer for the network don't match requirements of the network." I seem to need to enter a security key/passphrase to connect to the PC. Where do I find them?
    Thanks for your help.

    I assume that you have Wireless Security enabled on your AirPort's wireless network. The issue maybe that the PC is unable to use the WPA password itself and will require using the Equivalent Network Password instead.
    To get this password, you will use the AirPort Utility from the MacBook:
    Start the AirPort Utility > Select the AirPort base station > Manual Setup
    Now, before doing anything else, go up to the utility's menu bar at the top of the screen, and then, choose "Base Station," and then, Equivalent Network Password from the drop-down menu. You will see two items: 1) WPA Password, which should look familiar to you, and 2) WPA Pre-Shared Key. It should be a long hexidecimal set of numbers and letters. Jot down this second item.
    You will want to use the value you just jotted down when entering the password from the Windows Visa PC.

Maybe you are looking for

  • Flash Video with DVD-like motion menus -- Is this possible?

    Hi all, I just joined this gropup. I have some SMIL 2.0 presentations with synchnorized multiple audio (several languages supported) and video as well as DVD-like still and motion menus. These are semi-transparent menus and actually are super-imposed

  • Apple logo won't go away--frozen--wont connect to computer help-plzzzzzzzzz

    I was about to send in my iPod for repair, but I thought I might check if it happened to someone else here. My iPod I got 10 months ago just displays an Apple logo. The light will turn on, and off, it will reset and go to the diagnostics screen, but

  • HT4972 i am not able to activate my iphone after update ios5

    plz help me to activate my iphone coz its not responding after updating IOS5

  • Retrieving line-number of the last error

    Hello ! Is it possible to access the line number where the last error in a PL/SQL procedure occured ? At example: CREATE OR REPLACE PROCEDURE do_stupid IS tempNum Number; BEGIN      FOR i IN 1..5      LOOP           temp := sysdate;      END LOOP;   

  • Select All, Paste at end of movie?

    Each time I use QTx I enjoy one of the benefits removed. This is really just a player, with all it's power stripped away. Anyway, in QT Pro I used to be able to select a movie, then paste it at the end of another, making one longer movie. I can't see