Hi,
see this wiki
RSXMB_ARCHIVE_MESSAGES Archive XML Messages
RSXMB_CANCEL_NOT_REST_MESSAGES Cancel XI Messages With Errors That Cannot Be Restarted
RSXMB_DELETE_ARCHIVED_MESSAGES Delete Archived XML Messages
RSXMB_DELETE_MESSAGES Delete XML Messages from the Persistency Layer marked for DEL
RSXMB_CANCEL_MESSAGES Mass cancellation of error messages - XI
RSXMB_SHOW_REORG_STATUS & RSXMB_SHOW_STATUS provide an overview for all XML messages in XI persistency layer.
RSXMB_MESSAGE_STATISTICS2 which provides the processing statistics. This report basically analyzed the history table.
RXWF_XI_UNSED_MSGS report helps in converting messages states other than 003 to final state i.e. 003.
SXMS_REFRESH_ADAPTER_STATUS report helps in converting message sates like 001/008 into final state.
http://wiki.sdn.sap.com/wiki/display/XI/PIArchivingConceptual+Overview

Similar Messages

  • Message struck in adapter engine with status Hold

    Hi,
    In intergaration engine all messages are processed, I have checked SMQ1, SMQ2 (no message is struck in queue)
    where as messages struck in adapter engine with status Hold, I have checked this in RWB. How to resolve this?
    Regards,
    Krishna

    Hello,
    Below is some information on how to resolve this type of issue:
    1 - In the RWB, expand the tray for "Configure Table Columns" - by clicking on a square at the right end of this heading.
    2 - Check the checkboxes for "Serialization Context" and "Sequence Number". These should then appear in the table columns as well.
    3 - Add the Serialization Context to the Extended Filter Criteria. Search the messages in status HOLD based on this new additional criteria.
    4 - Sort the messages in ascending order based on the Sequence no.
    5 - Check the predecessor message of the first message in status "HOLD"
    Based on the following status for this predecessor messages, the actions that can be taken for the HOLD messages are:
    a - Predecessor is in Failed State/System Error : Cancel/Resend the
    first message in status HOLD after this. Then the remaining messages
    can be cancelled/resent.
    b - Predecessor is in DLVD state(delivered state) : First Holding
    message can be resent/cancelled followed by the others.
    c - Predecessor is in NDLV(Non-Delivered Status) : Check why the
    predecessor message failed and correct the reason for the failure.
    Then resend the predecessor message and then cancel/resend the
    remaining HOLD messages. Alternatively, you can directly try
    resending this NDLV predecessor message and see if it goes. If it
    goes, then the remaining HOLD messages can be resent/cancelled.
    Another option could be to cancel this NDLV predecessor message so
    that it goes to FAILED state and then cancel/resend remaining HOLD
    messages.
    Regards,
    Sarah

  • Message stuck in Adapter Engine queue with status "Delivering"

    Hi All,
    I have a File to File EOIO scenario. The messages are sucessfully delivered from IE to AE. All entries have a chequered flag in SXMB_MONI. No messages are stuck in IE queue (SMQ2). But the message is stuck in AE queue with status "Delivering". I can not resend or cancel the message coz the status is "delivering".
    The reason it is in "delivering" status is due to some config error that I made in Communication Channel FTP parameters. Now it is corrected. But how do I deal with this message now?
    Restart of server is not an option here. Is there are place I can delete the message from AE queue?
    Thanks
    Jaishankar

    You can see the queues status (and number of stuck entries etc) through the link:
    http://<host>:<port>/MessagingSystem/monitor/systemStatus.jsp
    There, you can maintain the queues.
    There is also a link for the EOIO Sequence Monitor:
    http://<host>:<port>/MessagingSystem/monitor/sequenceMonitor.jsp
    There you can see the stuck messages and maintain these.
    Make sure to handle the proper message IDs.
    All of these are acessible through the Messaging System main page:
    http://<host>:<port>/MessagingSystem/
    Regards,
    Henrique.

  • Messages stuck at Adapter engine

    Hi everyone,
    My messages are getting stuck at the Adapter engine level and shows the status as "Holding". But the step at Integration engine seems to work fine.
    How could i get rid of these messages, before I run another couple of messages.
    Also what could be the reason for the error.
    Thanks,
    Vinotha M
    Edited by: Vinotha M on Feb 23, 2009 5:59 PM

    Hi Vinotha,
    Apart from the blogs mentioned above dont forget to go through
    http://help.sap.com/saphelp_nw04/helpdata/EN/49/e3fb40ef74f823e10000000a155106/content.htm
    This would give you a greater insight into your the cause and analysis of your problem.
    Apart from the above link to avoid further cropping of the same problem you can " Start Prioritizing the Processing of Messages" http://help.sap.com/saphelp_nwpi71/helpdata/en/46/6ffe8effc20eede10000000a155369/content.htm
    Rgds
    joel
    Edited by: joel trinidade on Feb 24, 2009 9:55 AM

  • Messages Stuck in adapter engine but passing through Integration engine

    Hi All,
    SOAPFault Error. Error Code/Category: XI Protocol/ Wrong Value...Received HTTP Response Code 500: Error during Parsing of SOAP Header
    Above error as system error appears in adapter engine when messages are coming into SAP PI. At sender, we are having sender mail adapter.
    Adapter Modules are also configured in mail adapter.What could be the possible reason.
    Please suggest
    Regards,
    Kanisha

    Below is the error log. As per scenario, Mail To File.
    Please Suggest
    Regards,
    Kanisha

  • Messages got stuck in Adapter engine

    We are doing http to RFC sysnchronous scenario
    Message got stuck in adapter engine.so we are getting 500 HTTP timeout error in Http client.
    Please help us to find why messages got stuck in Adapter engine.
    Below Adapter engine audit log message is pasted for your reference.
    Audit Log message:
    Time Stamp Status Description
    26.09.2008 06:33:54 Success Message successfully received by messaging system. Profile: XI URL: http://devsap01:51000/MessagingSystem/receive/AFW/XI Credential (User): PIISUSER
    26.09.2008 06:33:54 Success Using connection RFC_http://sap.com/xi/XI/System. Trying to put the message into the request queue.
    26.09.2008 06:33:54 Success Message successfully put into the queue.
    26.09.2008 06:33:54 Success The message was successfully retrieved from the request queue.
    26.09.2008 06:33:54 Success The message status set to DLNG.
    26.09.2008 06:33:54 Success Delivering to channel: RFC_out_Test
    26.09.2008 06:33:54 Success MP: entering
    26.09.2008 06:33:54 Success MP: processing local module localejbs/RfcAFBean
    26.09.2008 06:33:54 Success RFC adapter received a synchronous message. Attempting to send sRFC for ZFTestRFC
    26.09.2008 06:33:54 Success RFC adapter received a synchronous message. Attempting to send sRFC for J2EE_GUEST
    ime Stamp Status Description
    26.09.2008 06:56:15 Success MP: leaving
    26.09.2008 06:56:15 Error Delivery of the message to the application using connection RFC_http://sap.com/xi/XI/System failed, due to: com.sap.aii.af.ra.ms.api.MessageExpiredException: Sync application request expired.. Setting message to status failed.
    26.09.2008 06:56:15 Error The message status set to FAIL.
    26.09.2008 06:56:15 Error Returning synchronous error message to calling application: com.sap.aii.af.ra.ms.api.MessageExpiredException: Sync application request expired..
    Kindly advise us on this issue.

    Hi krish,
           when i send a http request it got stuck in adapter engine with status "delivering" for some time....
    We found that RFC got successfully executed in R/3 system but the synchronous message is not delivered to PI.since adapter engine message is having status "delivering"
    after some time we got adapter engine message status as "cancelled with error"
    Error is Message expired exception which you can see audit log message I have pasted in my previous post.
    Meanwhile we also got HTTP timeout error in Http client.
    Could you please tell me why it got stuck in Adapter engine with status "delivering" since RFC is executed successfully.
    Why we are not getting synchronous message reply back to PI?

  • Purging EOIO messages with status "Holding" at the adapter level in XI.

    Hi,
    I want to purge a set of messages (some 800) with status "Holding" at Adapter level in RunTime Workbench. I have gone through the blog "/people/stefan.grube/blog/2006/04/27/how-to-deal-with-stuck-eoio-messages-in-the-xi-30-adapter-framework which explain the way to reprocess the messages which are stuck in EOIO so that the rest in queue are processed but is there a way to purge a large number of messages in a EOIO queue which are holding for long, at the adpater framework level thorugh some option in Runtime workbench or Visual Administrator of J2EE server on which XI is running ?

    Hi Gourav,
    What do you mean by delete files from folder.
    I have this problem and I can't get rid of the messages that are stuck in the adapter engine. 
    If I need step 3.  how is that done?
    Thanks.

  • How do I process messages with status = "Holding"

    Hi,
    How do I process messages with status = "Holding" from the RWB-Message Monitoring - Adapter Engine?
    I did a quick scan for records with errors in the same queue (ConversationID), but could not find any.
    I tried to cancel the one with the smallest sequential number, but I got the error - "Unable to cancel 1 of 1 messages; update the status"
    Please help.
    Thanks
    Sudheer

    Hi,
      "Holding comes into play when ur scenario is having multiple inbound interfaces and you checked "Maintained order at runtime"in interface determination in ID. Suppose  message will hit first inbound interface once it is successful then it will hit second inbound interface. If first inbound interface fails then most of the message will be in "Holding" status depends upon XI AF queues ID.
    I did a quick scan for records with errors in the same queue (ConversationID), but could not find any.
    You will not find bcoz of AE archiving settings.
    Try to check the with business guys, whether they need the order of processing. If not the case try to Uncheck the box "Maintain Order at runtime".
    Regards,
    Rao.Mallikarjuna

  • XI Adapter ? No messages in the adapter engine in RWB

    Hi Guys,
    I have the scenario SOAP-PROXY. I have configured XI Adapter on the receiver side. I have used xml spy to post the messages directly to the IS. I could not see any messages in the adapter engine in RWB.
    I have seen the messages processed successfully in the integration engine under RWB.
    can anybody explain why i could not see any messages in the adapter engine ? Is It normal with the xi adapter on the receiver side ?
    Thanks,
    Raj
    Message was edited by:
            raj reddy

    Raghu.
    I've done the following:
    1. I've executed SE38 tx code.
    2. I've entered the "RSXMB_DELETE_MESSAGES" report as "Program"
    3. As the "RSXMB_DELETE_MESSAGES" report does not have a selection screen, it must be executed with default parameters. So, I selected "Program -> Execute -> Background".
    4. There are no available variants, so I clicked on the "Execute immed." button.
    5. The job starts. I can monitor it on the SM37 tx code.
    6. It only deleted 20 messages.
    What I get from this, is that the "RSXMB_DELETE_MESSAGES" report cannot delete the big part of the messages since them are marked as "Archivable" and not as "Archived".
    what do you think of it??
    regards
    Carlos.

  • How to get Payload of SOAP Message in Advance Adapter Engine

    HI All,
    I am wondering if anybody can tell me how to view the Payload of SOAP Sender and Receiver Message in Advance Adapter Engine?
    Does Anybody know how to check mapping payload in Advance Adapter Engine because in ABAP you can see the mapping payload under Request Message Mapping but when you use AAE you can't see the Request Message Mapping Payload.
    I have a SOAP to RFC Scenario in which I can't see the SOAP Sender and RFC Receiver Mapping Payload.
    When I am sending incorrect data to an RFC I am getting this error which is very strange and new to me.
    com.sap.engine.interfaces.messaging.api.exception.MessagingException: Unable to split a synchronous message
    Any comments would be much appreciated.
    Thanks,
    Iqbal

    HI All,
    I have managed to find Michal's Blog which is talking about getting the mapping payload but unfortunately I don't know how to create Adapter Module so I am wondering if somebody can please provide me EAR file so that I will request the Basis guys to deploy the code and hopefully this will solve my query.
    Michal's Blog
    As you all probably know while using local Advanced Adapter Engine (AAE) processing in SAP PI 7.1 the message is logged only once (during processing by sender adapter). This is great in terms of performance but what if we need to check the mapping output? Is there a way do do it somehow? It turns out that we don't have such an option in standard yet. Is there any alternative then?
    It turns out there is - a simplest adapter module there is...
    Local AAE works in such a way that from the sender adapter it executes the receiver adapter so in the outbound message to PI processing you can see the adapter info logs of the receiver adapter and this is what we can use. The idea is to add an adapter module to the receiver adapter which will put the content of the message into the audit log of PI message processing. We can do it by writing a few lines of code:
    PI/XI: target message logging with local AAE not possible ? not anymore...
    *Please upload the file in any free site or <REMOVED BY MODERATOR>
    <READ RULES OF ENGAGEMENT>
    Thanks,
    Edited by: Prateek Raj Srivastava on Jan 6, 2012 9:10 PM

  • Message split on adapter engine for the java based IDoc adapter

    Hi Guys,
    Do you know if message split on adapter engine is available for the java based IDoc adapter on the single stack (PI 7.31)?
    I'm getting such exception when I try to post 3 IDocs
    Transmitting the message to endpoint <local> using connection File_http://sap.com/xi/XI/System failed, due to: com.sap.aii.af.idoc.exception.IDOCAdapterException: Error before sending due to idoc parsing error: (7) IDOC_ERROR_PARSE_FAILURE: Invalid XML 1.0 character encountered within IDocXML for type <ns0:Messages>:
    state=EXPECTING_IMMEDIATE_TAG_END, charPosition=68, lineNumber=1, columnNumber=69, invalidChar=U+0078,
    sourceSnippet=...UTF-8" standalone="no"?><ns0:Messages xmlns:ns0="http://sap.com/xi/XI/SplitAndMerge"><ns0:Message1><...
    ^
    Mapping is one to many.
    Each IDoc content has been compared manually against the xsd schema and it was fine.  
    I know that old way of modifying xsd is still possible.
    Best regards,
    Wojciech

    Did you find a solution to this? Having a similar error right now.
    Thanks and kind regards
    Jens

  • Macbook stuck on apple screen with status bar

    Macbook pro 17in stuck on apple screen with status bar
    i have snowleapord
    when i start in verpose mode it says this at the end:
    invalid node structure
    (4,38887)
    ** The Volume Macintosh HD could not be verified completly.
    /dev/rdisk0s2 (hfs) EXITED WITH SIGNAL 8
    fsck failed
    kext loading now disabled.
    Kext unloading now disabled.
    Kext autounloading now disabled
    Kernal requests now disabled.
    Can't get kexted prot.
    syncing disks... Killing all processes
    continuing
    done
    CPU Halted
    I havent tried re-starting from Start-up disk because I am not home for 5 more days and it is at home.
    If anyone could help or tell me my problem or point me in the right direction i would apreciate it.
    uploading image of verpose screen to flickr.. http;//www.flickr.com/photos/briannasue

    The disk utility program has found an error and cannot repair it - Disk Utility is not able to repair the drive it has been booted from. You'll need to restart the computer using another disk - this is one reason why I always travel with an emergency DVD and a bootable external drive. Invalid node structure errors are non-trivial; sometimes Disk Utility will repair them and sometimes not. Disk Warrior has been my second line of defence for disk drive problems for years.

  • May macbook late aluminum stuck on apple icon with loading icon how can i fix it? i tries doing the command p r thing

    may macbook late aluminum stuck on apple icon with loading icon how can i fix it? i tries doing the command p+r thing

    please help me asap. btw when i did the command p+r or command +option+p+r a lock icon with textbox at the bottom is there and i dont know what to type in.

  • I tried to export an iMovie to quicktime and got this pop up message, "file is already open with write permission" How do I resolve this. thans

    I tried to export an iMovie to quicktime and got this pop up message, "file is already open with write permission" How do I resolve this. thans

    Turn off Time Machine before you open iMovie. It's a semi-known issue right now.
    https://discussions.apple.com/message/17032254#17032254

  • How to process stucked holding messages in the Adapter Engine.

    Hi experts,
    This question is may be familier to all...
    There are thousands of messages are in holding status in the Adapter engine in RWB.
    I tried to found system error in these messages. There is no system error from the last in my investigation. I tried to restart of the communication channels of the combination of these messages. But it is also not use to fix this problem.
    Instead of the restart of the Java engine please let me know is there any possibility to fix this issue.
    Regards
    Mahesh

    Hello Mahesh
    You can try restarting some of the XI services (e.g. com.sap.aii.af.svc) but usually a java restart is required to free up these blocked threads/queues.
    Most likely these messages are in Holding status because there is a blockage in one of the Adapter queues. This can be monitored in the RWB
    -> Component Monitoring                                                
    -> Adatper Engine XIP                                                  
    -> Engine Status                                                       
    -> Additional Data   
    Find out what adapter queues are causing the blockage and increase the number of threads/queues available to it. This will help prevent the issue occuring again.
    See note #791655 Documentation of the XI Messaging System Service Properties, for an explaination of the queues.
    See these blogs for more details:
    1) /people/kenny.scott/blog/2007/08/20/messaging-system-queue-properties-after-xi-30-sp19-xi-70sp11
    2) /people/kenny.scott/blog/2008/12/05/xipi-file-and-jdbc-receiver-adapter-performance-and-availability-improvements
    Ensure note #937159 XI Adapter Engine is stuck, has been applied. 
    Regards
    Mark

Maybe you are looking for

  • Error while executing the SOAP-XI-JDBC(syn) scenario

    Dear Forum, We have done SOAP-XI-JDBC(synch) scenario with out BPM. When we sent the request data from EP to Oracle database through XI, we got an error,Runtime in Message-Mapping transformation~. com.sap.aii.utilxi.misc.api.BaseRuntimeException: Run

  • Problem in  vendor invoice creation through BAPI

    I am trying to create vendor invoice using bapi_acc_document_post but what value have be passed to obj_key and obj_typ fields of header is not clear to me. regards, anu

  • Installing a windows 7 (64 bit) printer driver to existing windows xp network

    Dear-Users......... i have connected 5 computers through a switch and ( hp laserjet 2014) printer is directly connected to one of them and shared on the network.  3 computers running on windows xp and one i added last time it was windows 7 (32 bit) i

  • Help with display

    I use my Curve 8530 to navigate on trips.  My question is, how can I keep the screen for going dark so I can read my directions without having to hit a button to wake it up every few minutes? Got my first ever Blackberry on 8/10/2010 Curve 8530 Solve

  • I can't install any extension in Safari 5.1.9.

    Hello, I am trying to install an extension to Safari (5.1.9.) however I get an error message after which the install button disappears and it says: Install Failed. Please try again later. - I have tried deleting the user/library/caches/com.apple.Safa