Meter reading in IFCU

Hi Experts ,
I am facing one problem while entering the fuel consumption along
with the Meter reading in IFCU.
In IFCU , system allowes me to enter the fuel comsumption but the Kilometer
entry field is gray.
I checked all the custamisation setting ....
Plz tell me , if i missed out some thing.
Thanks in Advance

Hello Dear
               have u defined measuring position in measuring points , and same in spro in fleet managment
Jitender

Similar Messages

  • Multiple Meter Reads on the same day and Billing

    Hi All,
    There is a requirement to hold all reads received from Customer/ Meter Reader etc even they these are received on the same day for e.g. schedule read could be received in the morning, followed by customer read through internet and then another customer read through IVR system.
    Can we store multiple reads on the same day?
    If a read goes into implausible and then it's corrected, implausible read is replaced by corrected read. Is there any way to store old implausible read?
    Thanks in advance.
    SJ

    Your questions answered below:
    1. So my question is can we enter multiple reads to the Meter on a single day with same meter read reason? - Yes when we have MR reason which is not relevant to billing. In your case its 09 which is nonrelevant and you should be able to enter multiple reads with different time.
    Make sure you supply time also when you are submitting your read. However there is a restriction of what level you can enter multiple MRs since SAP stores read at Minute level so you can not post 2 reads in same minute.
    2. Are there any configurations to be done to allow multiple meter readings on a single day? - Not sure but standard SAP should allow you to save multiple MRs with the above rules.
    Cheers
    Jignesh

  • Error while uploading meter reads through BAPI_MTRREADDOC_UPLOAD

    Hi,
    I am trying to estimate and upload meter reads on an installation through function module ISU_REGISTER_ESTIMATE and BAPI_MTRREADDOC_UPLOAD respectively. The output estimated read from ISU_REGISTER_ESTIMATE is fed to BAPI_MTRREADDOC_UPLOAD after removing decimal places, comma etc.
    While this works perfectly each time, there is one instance where this arrangement is not working. If the previous read is too large ( and plausible), in certain cases BAPI_MTRREADDOC_UPLOAD fails to upload the next read and gives an error with error description 'Format of MR 17737 not valid (MR document number 105677 ) '.
    As I said, both the function modules are workinf fine most of the times. However at certain instances it ends up with this error. Anyone encountered this problem before?
    All suggestions are welcome !
    Thanks in advance,
    AM

    Hi,
    Message - 'Format of MR 17737 not valid (MR document number 105677 ) signifies that number of pre-decimal places and number of post decimal places do not match with your register group configuration.
    Since, you are suggesting that your logic works in most of the cases, I think when meter overflow happens and while you are converting it to actual read - this reading do not match with pre-decimal and post decimal places.
    You need to double click on register group for a device, where you are facing this issue and then compare your calculated read in your code.
    Hope this helps.
    Regards,
    Avinash

  • Automatic creation of meter reading order with RR 01 after move in

    Hi Experts,
    I am working with DM module of SAP ISU. Currently I am facing a problem that after move-in a periodic order with RR 01 is created automatically by the system.
    Ex: Move in date is 01.01.2010. Monthly Portion is used with Schedule record 01.01.2010, 01.02.2010, 01.03.2010, 01.04.2010 and so on.
    If current system date is 20.07.2010 then Meter reading order is created automatically by the system for sch MRD 01.08.2010.
    Please let me know how to overcome this problem
    Thanks in advance.

    Thanks for your reply but I have cheked SPRO setting the suggested check box is already uncheked.
    I beleive the setting you have suggested is meant for default meter reading during move in but my problem is automatic creation of meter reading order with reason 01 during move in

  • I'm trying to submit a gas meter reading and have gotten a message that says firefox is "too modern" How do I fix this?

    I got an error message that says the web browser I have is too modern and it won't allow me to submit my gas meter reading.
    == This happened ==
    Not sure how often
    == I signed on to my gas company website and couldn't submit my meter reading

    Hello Carol,
    could you maybe try to use the [https://addons.mozilla.org/de/firefox/addon/1419/ IETab] add-on?
    Kind regards,
    Tobbi
    Firefox Support Volunteer

  • Previous Meter Reads and Usage are not  correct after meter Proration

    It seems that during proration there are two meter reading available the one with the Meter Reading type as 03 ( Automatic Estimation ) and other is Meter Reading type 01 - MR By employee that is being  retrieved. The 03 reading type seems to be the reading after the proration and the o1 reading is the reading done before the proration . The reads are coming out on our invoices incorrectly. Usually there will only be one Meter reading  to be picked up. but it seems do proration it splits meter into 2 entries.  The entry  with with metering type 01 has the correct previous  and current meter reads but incorrect usage. The entry with meter read 03 has the incorrect previous meter read and correct current meter read but incorrect usage. Our print work bench generated fiction is  calling SU_DB_ERCHZ_SELECT_BILL_NEW  to retrieve the values but the values that it retrieves are not correct., The second records is being put on the invoice. The form that exist in the  SU_DB_ERCHZ_SELECT_BILL_NEW  is called  db_erchz_select_join and  is used to retrieved the usage and meter reads.. This information is then passed  to out user exit.
    The previous meter read  should be 5,073,998     and the usage should be 7500   
    Service       Meter No.       Previous Read       Current Read        Usage
    Water            750009               5,092,748              5,148,998            56250

    Try resetting the PMU…
    http://docs.info.apple.com/article.html?artnum=14449
    … and then subsequently calibrating your battery…
    http://docs.info.apple.com/article.html?artnum=86284

  • Meter Reading date – estimating EL30

    Morning,
    Do you know how can I change the meter reading date when I run the estimation process through transaction EL30?
    See the problem.
    This customer has a custom estimation development. But, I see that meter reading date in the estimation enhancement is set with the scheduled meter reading date.
    However, I would need to change this date to the system-date when the estimation is triggered through tx. EL30.
    Is there any enhancement before the estimation module, to change the meter reading date automatically?
    Thanks.

    Hi,
    use function module ISU_DB_TE418_SELECT_DAT_TUR_NX or ISU_DB_TE418_SLCT_N_ADATSOLL_T for the next date and ISU_DB_EANL_SINGLE_ALL_TS to get the MRU of the installation first.
    KR
    Uwe

  • Meter reading order simulation

    Hello experts,
    I need to "simulate" meter reading order creation process, to download orders (EL35, with specific formkey) and use the file for external system.
    Is this possible?
    Thanks,
    Angela

    Hello Olivia,
    thank you for your answer, but i'm afraid I don't understand it properly.
    I thounght  ISUMSORDER was for working order not for meter reading; is it not correct?
    I need to simulate meter reading order, I mean to use EL35 but without filling db tables EABL/EABLG.
    thanks,
    Angela

  • Creation of Meter Reading Order

    Hi,
    My uploading program creating Meter Reading order using the function module ISU_S_METERREAD_CREATE. MRO is created Successfully for Meter Reading Reason 06. The Problem is Metering scheme is not Displaying in the Table EANL for the particular Subinstallation.
    Any one help me pls.
    Thanks in Advance
    Lakshmi

    Hi,
    Use Blocking Reason in ES31 (installation: Billing/Meter Reading control Tab)...During meter reading order creation, prevents meter reading orders from being created for the registers allocated to the installation.

  • Function Module/BAPI  for Meter Reading Entry(EL28)

    Hi Experts,
    Can anyone tell me about BAPI/Function Module for EL28(Meter Reading Entry).Standard FM is preferable.
    Thanks & Regards,
    Radharaman Haldar
    Moderator note - Thread locked, no research.
    Edited by: William Eastman on Mar 8, 2011 5:17 PM

    ISU_VALIDATION_DEPENDENT & ISU_DETERMINE_VALIDATION.
    The above two function module is used for the validation of Plausible or Implausible meter reading.

  • Meter read not picked up

    hi all,
    when i try to bill the meter read is not picked up by the billing. i try to bill for period 01-jul-10 to 31-jul10 there is a meter read on 20-jul-10 but still when i bill it does not pickup, i am not getting any error also.
    please can anyone guide me
    thanks in advance.

    The stop read can come from different sources, Stop read can come from SA/SP link, if the link was stopped OR Removal Read from SP/Meter Installation history, if the Meter was removed.
    Other than above, system would look for the next Scheduled Read Date for the SPs Meter Read Cycle which is: (after the end date of the last bill segment + Rate Frequency's Minimum Offset Days) AND before the Cutoff date of billing.
    Also note:
    - This depends on the Billing Option that you have selected for the Online Bill, i.e. "Use Cutoff Date" OR "Use Schedule". Batch billing by default uses "Use Schedule" method. "Use Cutoff Date" will look for meter reads as of the cutoff date.
    - Rate Frequency is the Frequency defined on the SA Types Rate Schedule. Frequency configuration has the Min./Max. Offset days values.
    So, in your case Scheduled Read Date will be searched between, for e.g. 06-JUL-2010 (01-JUL-2010 + (lets say) 5 Days) and 31-JUL-2010.
    If no Scheduled Read Date was found, the SA is skipped from billing. This is what happened in your original post.
    If Scheduled Read Date was found, system will check for available reads between (Schedule Read Date - N1 Days) and (Schedule Read Date + N2 Days), here N1 = Rate Frequency's Min. Offset days and N2 = Rate Frequency's Max. Offset days. Lets assume your frequency offset days are 5.
    Now, lets say you defined the Scheduled Read Date = 31-JUL-2010. So system will check for reads between 26-JUL-2010 (31-JUL-2010 - 5) and 05-AUG-2010 (31-JUL-2010 + 5).
    Your read is on 20-JUL-2010 hence system is not able to find it.
    This may relate to your second post.

  • BAPI for meter reading order (MRO) Reversal

    Hi Experts,
    Please let me know if there is any FM or BAPI for meter reading order reversal, Similar to EL37
    Regards
    Bikas

    Hello Bikas,
    Though this is an old post, thought of replying for the sake of googlers who might look for a solution for your query...the below code works!
    *---Begin Of Code
      TYPES : BEGIN OF ty_meter_orders_data,
               anlage   TYPE eablg-anlage,
               adatsoll TYPE eablg-adatsoll,
               ablesgr  TYPE eablg-ablesgr,
              END OF ty_meter_orders_data.
      DATA : lt_meter_orders_data TYPE STANDARD TABLE OF ty_meter_orders_data,
                  xy_ieabl_delete   TYPE  eabl_tab,
                  xy_ieablg_delete  TYPE  eablg_tab,
                  xy_ietrg_delete   TYPE  etrg_tab,
                  x_anlage type anlage,
                  x_retro_upd_date type adatsoll,
                  y_return type char1.
      DATA : y_obj TYPE  isu17_meterread.
    *--Get the needed data for reversal
      SELECT a~anlage
             a~adatsoll
             a~ablesgr
        FROM eablg AS a
        INNER JOIN eabl AS b ON a~ablbelnr = b~ablbelnr
        INTO TABLE lt_meter_orders_data
        WHERE a~anlage = x_anlage AND
              a~adatsoll >= x_retro_upd_date AND
              b~ablstat = '0'. "MR Order
      IF sy-subrc = 0.
        SORT lt_meter_orders_data BY anlage ablesgr adatsoll.
        DELETE ADJACENT DUPLICATES FROM lt_meter_orders_data COMPARING anlage ablesgr adatsoll.
        SORT lt_meter_orders_data BY adatsoll DESCENDING.
        LOOP AT lt_meter_orders_data ASSIGNING FIELD-SYMBOL(<fs_meter_orders_data>).
          CALL FUNCTION 'ISU_O_METERREAD_OPEN'
            EXPORTING
              x_anlage              = <fs_meter_orders_data>-anlage
              x_adatsoll            = <fs_meter_orders_data>-adatsoll
              x_ablesgr             = <fs_meter_orders_data>-ablesgr
              x_select2             = '5'
              x_wmode               = '6'
            IMPORTING
              y_obj                 = y_obj
            EXCEPTIONS
              not_found             = 1
              foreign_lock          = 2
              internal_error        = 3
              input_error           = 4
              existing              = 5
              number_error          = 6
              general_fault         = 7
              system_error          = 8
              manual_abort          = 9
              gasdat_not_found      = 10
              no_mrrel_registers    = 11
              internal_warning      = 12
              not_authorized        = 13
              not_qualified         = 14
              anpstorno_not_allowed = 15
              already_billed        = 16
              dev_already_prep      = 17
              OTHERS                = 18.
          IF sy-subrc = 0.
            CALL FUNCTION 'ISU_O_METERREAD_ACTION'
              EXPORTING
                x_okcode             = 'PSAV'
              CHANGING
                xy_obj               = y_obj
              EXCEPTIONS
                cancelled            = 1
                failed               = 2
                action_not_supported = 3
                system_error         = 4
                input_error          = 5
                not_customized       = 6
                OTHERS               = 7.
            IF sy-subrc = 0.
              CALL FUNCTION 'ISU_O_METERREAD_ACTION'
                EXPORTING
                  x_okcode             = 'SAVE'
                TABLES
                  yt_eabl_delete       = xy_ieabl_delete[]
                  yt_eablg_delete      = xy_ieablg_delete[]
                  yt_etrg_delete       = xy_ietrg_delete[]
                CHANGING
                  xy_obj               = y_obj
                EXCEPTIONS
                  cancelled            = 1
                   failed               = 2
                  action_not_supported = 3
                  system_error         = 4
                  input_error          = 5
                  not_customized       = 6
                  OTHERS               = 7.
              IF sy-subrc = 0.
                COMMIT WORK.
              ENDIF.
            ENDIF.
            CALL FUNCTION 'ISU_O_METERREAD_CLOSE'
              CHANGING
                xy_obj = y_obj.
    * Implement suitable error handling here
          ELSE.
            y_return = 'E'.
          ENDIF.
        ENDLOOP.
        IF y_return <> 'E'.
          y_return = 'S'.
        ENDIF.
      ELSE
    *    RAISE no_mtr_read_ordrs_found.
      ENDIF.
    *---End of Code
    Thanks.
    Mohammed.

  • Mass Meter reading results reversal.

    Dear All,
    For Reversal of meter reading we are using EL37 trasaction and these FM's (ISU_METERREAD_CANCEL or ISU_O_METERREAD_ACTION) will also help us for our enhancements.
    Anyway, here my requirement is Need to reverse bulk meter reading results by giving the only multiple installations in a selection criteria.
    At  EL37 we does not have the multiple installation selection criteria...so please help me the way on this instead of (EL37)BDC development.
    Regards,
    Joshi
    Edited by: Josh on Aug 20, 2010 10:25 AM

    Hello Joshi,
    Please see the following thread:
    Meter Reading Reversal
    The information here shoudl be helpful.
    Please dont forget to search threads for answers.
    Regards
    Olivia

  • EL 27 Correction of Implausible Meter Reads

    Hi All,
    I am trying to release impalusible Meter Readings via TCode EL27, by entering a Premise. Two things are happening:
    1. Direct Release of MR occurs . (no idividual correction screen opens)
    2. Individual Correction screen opens. (no direct release)
    I debugged quite a few cases and have reached a few conclusions:
    FOR INDIVIDUAL CORRECTION SCREEN TO OPEN:
    Pre-requisite = Value of ORIGIN_ESTIM = 6
    With this pre u2013 requisite, when there is 1 installation, with 1 register then in EL27, individual correction screen will open and MRu2019s can be edited.
    FOR DIRECT RELEASE:
    Apart from the above prerequisite & condition, FOR u201CANY OTHERu201D CONDITION, the correction screen will not open and MRu2019s cannot be edited.
    Value of Origin_estim can be viewed on the individual correction screen "Execute Correct Implausible Meter Reading Results" screen; Forecast data tab--> Origin
    Values of Origin:
    1 - Past MR results
    2 - Period Consumption
    3 - Reference value
    4 - Proration
    5 - External Determination
    6 - Estimation not Possible
    Also, is this phenomenon of direct release/ correction screen display DEPENDENT on MR REASON???
    Thanks in advance,
    Prajakt Dhumal
    Edited by: prajakt k dhumal on Oct 28, 2010 9:28 AM

    Hello,
    It should be possible to get to the correction screen by selecting the line you want to correct an click on 'correct'...
    You could skip this and release directly but there should be always an option to go into the correction screen as long as the meter reading is "still implausible".
    Only time this happens is if the meter reading is automatically plausible e.g. if no extrapolation was possilbe. You should get a
    message about this.
    It will only enter the correction screen if there is an "invalid meter reading result". If it is valid now (without doing changes) there is no need for correction anymore therefore it is released immediately.
    The correction screen is not build to handle more than one meter reading at a time. Hence there is no way you correct more than one meter reading at the same time i.e. count_eabl >= 2.
    Hope this is helpful ...
    Regards
    Olivia

  • Change meter reading type during reading estimation (el30)

    Hi,
    I would change meter reading type during or after reading estimation process (el30 transaction), just before the meter reading upload.
    Is there any user-exit to activate to do this?
    Thanks

    Hi,
    You can use enhancement - EDMLELSV / EDMLELAA
    Let me know if more information is required.
    Thanks and Regards,
    Ranjit Thakur.

Maybe you are looking for

  • Query performance.

    Hi I have created a procedure that accepts two bind variables from a report. The user will select one or the other, both or neither of the variables. To return the appropriate results i have created a view with the entire result set and in the proced

  • My macbook was very slow  .

    -How could i delete the window7 on my macbook -I forgot my password for my Macbook to so i can't update the falsh player, what shold i do to reset it        thanks,

  • A query in AdventureWorks2012

    Hi, i have faced with a problem when i was working on a query in AddentureWorks2012 db the query is as a follow : show the name of product next to its sum(OrderQty) in each years LIKE:      Year          |      Name   | Quantity               2005   

  • IPhone photo albums issues

    So I have an issue. All the .gif files I have on my computer that I upload to my phone via iTunes (syncing photo albums) are magically converted to .jpg files. This is incredibly annoying because I want them to be animated when I email or text them.

  • Agent job step - using print statement in tsql step doesnt show up

    I want to execute a procedure, then use print to write a short message into the job history.  The step executes fine, but the message doesnt show up in the history. print 'hello' what gives?