Microsoft failover cluster virtual adapter IP Address

Hi,
Please let me know how we can change the IP Address of Microsoft failover cluster virtual adapter in Windows 2012 R2.
Regards,
Hakim. B
Hakim.B Sr.System Administrator

Within Cluster Manager console, select the cluster in the left-hand pane.
At the bottom of of the center pane, expand Server Name.
Right-click IP Address and select Properties.  Change the address.
.:|:.:|:. tim

Similar Messages

  • Microsoft Failover Cluster Virtual Adapter

    I have read the following blog about Microsoft Failover Cluster Virtual Adapter and have few questions.
    http://blogs.technet.com/b/askcore/archive/2009/02/13/what-is-a-microsoft-failover-cluster-virtual-adapter-anyway.asp
    How does this adapter choose the IP address?  It seems that it is using 169.254 subnet address.
    Can the IP address changed? If yes, how to change it in Windows 2008 R2?
    What tool is used to show the kernel drivers?  The blog shows a screenshot below the sentence The Cluster network driver (netft.sys) is a kernel mode driver and is started and stopped by the Cluster
    Service.
    If the physical NIC which has the same MAC address of the adapter is disabled, will that cause problem?
    Thanks.

    Hi PCSQL66,
    Firstly, NetFT self-configures an APIPA adres and no manuel user config requireds. Then MAC adress is self-generated based on a hash of MAC address of the first enumerated (by NDIS) physical NIC in the clsuter node. You know Netft is a virtual network adapter.
    And you cannot change it and you dont need to change.
    You are right about MAC address conflict but mac address conflict detection and rersolution in Win2012.
    I think what you want to see about kernel mode drivers or user mode etc you can use the sysinternal utility. 
    I want to say NDIS 6.2 is miniport virtual adaptor.

  • WWW service is not able to start via Microsoft Failover Cluster generic service resource

    Environment
    Cluster Nodes = two
    Cluster Nodes OS = Windows 2008R2
    Application = IIS
    Query
    I created generic service resources of many windows services under Microsoft Failover Cluster and they are failing over successfully but when I create a generic service resource for WWW, then the WWW service is not able to online
    via Microsoft Failover Cluster. It stuck in online pending.
    I have noticed two things.
    1.) If the WWW service is set to manual and started at passive node and I manually restart the Active node then the WWW service successfully switch over to stand by/passive node. but if the WWW service is set to
    manual and not started on stand by/Passive node then the WWW service is not failing over.
    2.) if I kill the WWW service manually (as a test case) on Active Node via this command (taskkill /f /pid XXXX) then the WWW service failed and is not failing
    over to standby/passive node.
    Any comment will be appreciated. Thanks. Zahid Haseeb.

    The problem is resolved. I feel that it will be helpful to other people who may face the same problem which I faced, so I wrote a blog on "How to configure IIS Web Site and Application Pool in Microsoft Failover Cluster" and mentioned almost all activities
    which I have done. Kindly see the resolution under section "Configure some changes in Cluster Configuration" in the below link
    http://zahidhaseeb.wordpress.com/2014/02/12/how-to-configure-iis-web-site-and-application-pool-in-microsoft-failover-cluster/
    Any comment will be appreciated. Thanks. Zahid Haseeb.

  • In windows2012, IIS is not able to configure in Microsoft Failover Cluster

    Hello All
    I configured IIS under Microsoft Failover Cluster with the help of below link. The setup is working successful. I configured this on Windows2008.
    http://support.microsoft.com/kb/970759/en-us
    I verified below as test cases.
    1.) I kill PID of W3SVC , the failover executed.
    2.) I stopped the Default Web Site, the failover executed.
    3.) I stopped the Default Application Pool, the failover executed.
    4.) I stopped the other Application Pools, the failover executed(after changing the script under above mentioned link).
    PLEASE NOTE: I used the following links to configure the setup on Windows2008 and Windows2012
    http://zahidhaseeb.wordpress.com/2014/02/12/how-to-configure-iis-web-site-and-application-pool-in-microsoft-failover-cluster/
    But, when I create the same environment under Windows2012, see what happen below.
    I verified below as test cases.
    1.) I kill PID of W3SVC , the failover executed.
    2.) I stopped the Default Web Site, the failover executed.
    3.) I stopped the Default Application Pool, the failover executed.
    4.) I stopped the other Application Pools, the failover is not executed(after changing the script under above mentioned link).
    Any comment will be appreciated. Thanks. Zahid Haseeb.

    Hi,
    As the KB mentioned, Microsoft recommends administrators carefully evaluate the use of Network Load Balancing (NLB) as the primary and preferred method for improving the scalability and availability of Web applications with multiple servers running IIS 7.5
    or IIS 7.0, as opposed to using failover clustering.
    It is important to consider that clustering IIS by means of clustering the IIS services does not always guarantee a high availability solution for Web applications.
    While the IIS services (specifically the WWW service) might be up and running, a specific application pool’s hosting process could have terminated, or the application might be throwing internal server HTTP errors. Clustering the Web applications and
    monitoring their health by using a custom script is the correct and recommended way to achieve a high availability IIS cluster using failover clustering. Below is a sample script that monitors the state of an application pool to determine if it is started
    or not.
    That’s more about the IIS issue, maybe you can ask more detail question in IIS forum.
    IIS support forum
    http://forums.iis.net/
    Thanks for your understanding and support.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SAP Microsoft failover cluster

    Hello,
    I have Installed NW 7.31 Microsoft Failover cluster for one of  my production System.I want to test the Backup & Recovery for this system.
    Kindly provide me with certain Information or Document to test the Backup Scenario & thus Restoring it.
    Thanks,
    Nimish

    Hi Deepak,
    Thanks for the Reply
    I am able to take Backup in Failover cluster through BRTOOLS Functionality but while restoring, it gives an error "Executionf BRRECOVER Finished with return code 5".
    1. While restoring , I have to shutdown the Services.
    2. While the services are shutdown, shared drives shift to other Nodes which conatins the Backup taken through brtools.
    3. Therefore while restoring ,I dont have the particular path where the files has to be restored.
    Pl. provide some Input for Restore Issue
    Thanks,
    Nimish 

  • Hyper-V Failover Cluster virtual guests suddenly reboots

    The environment is Server 2012 R2 using dual clusters--a Hyper-V Failover Cluster running guest application virtual machines and a Scale-Out File Server Cluster using Tiered Storage Spaces which are used to supply SMB3 shares
    for Quorum and CSV. Has anyone had this problem?

    Anything relevant in the host or guest event logs? I would also check the cluster event logs to see if there are any indications there as well.
    Does the guest go down hard or gracefully reboot?
    Need more info.
    Andy Syrewicze
    Come talk more about Hyper-V and the Microsoft Server Stack at
    Syrewiczeit.com and the Altaro Hyper-V Hub!
    Post are my own and in no way reflect the views of my employer or any other entity in which I produce technical content for.

  • Microsoft Failover Cluster (HA)

    Hey Guys,
    Let me a quick question:- Please read my concern and share your thoughts.
    Q. I have one HA in my environment and HA runs as Active Passive. Suppose I make it offline primary
    server but HA is not moving another node.
    What should be cause ? 
    Ram Prakash Sharma

    Hi Ram Prakash Sharma,
    If your cluster can pass all the validation settings please first check whether you have configure the preferred node correctly, you can refer the following article to realize
    how to setting the preferred owner.
    Preferred Owners in a Cluster
    http://blogs.msdn.com/b/clustering/archive/2008/10/14/9000092.aspx
    I’m glad to be of help to you!
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Failover cluster failed due to mysterious IP conflict ?

    I'm having a mysterious problem with my Failover cluster,
    Cluster name: PrintCluster01.domain.com
    Members: PrintServer01.domain.com andPrintServer02.domain.com
    in the Failover Cluster Management – Cluster Event I received the Critical error message 1135 and 1177:
    Log Name: System
    Source: Microsoft-Windows-FailoverClustering
    Date: 15/06/2011 9:07:49 PM
    Event ID: 1177
    Task Category: None
    Level: Critical
    Keywords:
    User: SYSTEM
    Computer: PrintServer01.domain.com
    Description:
    The Cluster service is shutting down because quorum was lost. This could be due to the loss of network connectivity between some or all nodes in the cluster, or a failover of the witness disk.
    Run the Validate a Configuration wizard to check your network configuration. If the condition persists, check for hardware or software errors related to the network adapter. Also check for failures in any other network components to which the node is
    connected such as hubs, switches, or bridges.
    Log Name: System
    Source: Microsoft-Windows-FailoverClustering
    Date: 15/06/2011 9:07:28 PM
    Event ID: 1135
    Task Category: None
    Level: Critical
    Keywords:
    User: SYSTEM
    Computer: PrintServer01.domain.com
    Description:
    Cluster node 'PrintServer02' was removed from the active failover cluster membership. The Cluster service on this node may have stopped. This could also be due to the node having lost communication with other active nodes in the failover cluster. Run
    the Validate a Configuration wizard to check your network configuration. If the condition persists, check for hardware or software errors related to the network adapters on this node. Also check for failures in any other network components to which the node
    is connected such as hubs, switches, or bridges.
    After further investigation, I found some interesting error here, from the very first critical error message logged in the Event viewer on PrintServer02:
    Log Name: System
    Source: Tcpip
    Date: 15/06/2011 9:07:29 PM
    Event ID: 4199
    Task Category: None
    Level: Error
    Keywords: Classic
    User: N/A
    Computer: PrintServer02-VM.domain.com
    Description:
    The system detected an address conflict for IP address 192.168.127.142 with the system having network hardware address 00-50-56-AE-29-23. Network operations on this system may be disrupted as a result.
    192.168.127.142 --> secondary IP of PrintServer01
    how could that be possible it conflict by one of the PrintServer01 node ? the detailed is as below:
    **From PrintServer01**
    Ethernet adapter Local Area Connection* 8:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Microsoft Failover Cluster Virtual Adapter
    Physical Address. . . . . . . . . : 02-50-56-AE-29-23
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 169.254.1.183(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.0.0
    Default Gateway . . . . . . . . . :
    NetBIOS over Tcpip. . . . . . . . : Enabled
    I have double check in all of the cluster members that all IP addresses is now unique.
    however I'm sure that I the IP is static not by DHCP as from the IPCONFIG results below:
    From **PrintServer01** (the Active Node)
    Windows IP Configuration
    Host Name . . . . . . . . . . . . : PrintServer01
    Primary Dns Suffix . . . . . . . : domain.com
    Node Type . . . . . . . . . . . . : Hybrid
    IP Routing Enabled. . . . . . . . : No
    WINS Proxy Enabled. . . . . . . . : No
    DNS Suffix Search List. . . . . . : domain.com
    domain.com.au
    Ethernet adapter Local Area Connection* 8:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Microsoft Failover Cluster Virtual Adapter
    Physical Address. . . . . . . . . : 02-50-56-AE-29-23
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 169.254.1.183(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.0.0
    Default Gateway . . . . . . . . . :
    NetBIOS over Tcpip. . . . . . . . : Enabled
    Ethernet adapter Cluster Public Network:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Intel® PRO/1000 MT Network Connection
    Physical Address. . . . . . . . . : 00-50-56-AE-29-23
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 192.168.127.155(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    IPv4 Address. . . . . . . . . . . : 192.168.127.88(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    IPv4 Address. . . . . . . . . . . : 192.168.127.142(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    IPv4 Address. . . . . . . . . . . : 192.168.127.143(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    IPv4 Address. . . . . . . . . . . : 192.168.127.144(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    Default Gateway . . . . . . . . . : 192.168.127.254
    DNS Servers . . . . . . . . . . . : 192.168.127.10
    192.168.127.11
    Primary WINS Server . . . . . . . : 192.168.127.10
    Secondary WINS Server . . . . . . : 192.168.127.11
    NetBIOS over Tcpip. . . . . . . . : Enabled
    Ethernet adapter Cluster Private Network:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Intel® PRO/1000 MT Network Connection #2
    Physical Address. . . . . . . . . : 00-50-56-AE-43-EC
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 10.184.2.2(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    Default Gateway . . . . . . . . . :
    NetBIOS over Tcpip. . . . . . . . : Disabled
    From **PrintServer02**
    Windows IP Configuration
    Host Name . . . . . . . . . . . . : PrintServer02
    Primary Dns Suffix . . . . . . . : domain.com
    Node Type . . . . . . . . . . . . : Hybrid
    IP Routing Enabled. . . . . . . . : No
    WINS Proxy Enabled. . . . . . . . : No
    DNS Suffix Search List. . . . . . : domain.com
    domain.com.au
    Ethernet adapter Local Area Connection* 8:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Microsoft Failover Cluster Virtual Adapter
    Physical Address. . . . . . . . . : 02-50-56-AE-5F-E5
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 169.254.2.86(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.0.0
    Default Gateway . . . . . . . . . :
    NetBIOS over Tcpip. . . . . . . . : Enabled
    Ethernet adapter Cluster Public Network:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Intel® PRO/1000 MT Network Connection
    Physical Address. . . . . . . . . : 00-50-56-AE-79-FA
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 192.168.127.172(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    IPv4 Address. . . . . . . . . . . : 192.168.127.119(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    Default Gateway . . . . . . . . . : 192.168.127.254
    DNS Servers . . . . . . . . . . . : 192.168.127.10
    192.168.127.11
    Primary WINS Server . . . . . . . : 192.168.127.11
    Secondary WINS Server . . . . . . : 192.168.127.10
    NetBIOS over Tcpip. . . . . . . . : Enabled
    Ethernet adapter Cluster Private Network:
    Connection-specific DNS Suffix . :
    Description . . . . . . . . . . . : Intel® PRO/1000 MT Network Connection #2
    Physical Address. . . . . . . . . : 00-50-56-AE-77-8D
    DHCP Enabled. . . . . . . . . . . : No
    Autoconfiguration Enabled . . . . : Yes
    IPv4 Address. . . . . . . . . . . : 10.184.2.3(Preferred)
    Subnet Mask . . . . . . . . . . . : 255.255.255.0
    Default Gateway . . . . . . . . . :
    NetBIOS over Tcpip. . . . . . . . : Disabled
    Any help would be greatly appreciated.
    Thanks,
    AWT
    /* Server Support Specialist */

    I
    am facing the same scenario as the original poster. This is on Server 2008 R2 SP1.
     WIndow event log entries follow the same pattern. The MAC address listed in connection with the duplicate IP belonged to the passive node.
    Interestingly, the Cluster.log begins to explode with activity a few milliseconds before the first Windows event is logged.
    2012/07/11-15:20:59.517 INFO  [CHANNEL fe80::8145:f2b9:898e:784e%37:~3343~] graceful close, status (of previous failure, may not indicate problem) ERROR_IO_PENDING(997)
    2012/07/11-15:20:59.517 WARN  [PULLER SQLTESTSQLB] ReadObject failed with GracefulClose(1226)' because of 'channel to remote endpoint fe80::8145:f2b9:898e:784e%37:~3343~
    is closed'
    2012/07/11-15:20:59.517 ERR   [NODE] Node 1: Connection to Node 2 is broken. Reason GracefulClose(1226)' because of 'channel to remote endpoint fe80::8145:f2b9:898e:784e%37:~3343~
    is closed'
    2012/07/11-15:20:59.517 WARN  [RGP] Node 1: only local suspects are missing (2). moving to the next stage (shortcut compensation time 05.000)
    2012/07/11-15:20:59.548 WARN  [NETFTAPI] Failed to query parameters for fe80::5efe:169.254.1.79 (status 80070490)
    2012/07/11-15:20:59.548 WARN  [NETFTAPI] Failed to query parameters for fe80::5efe:169.254.1.79 (status 80070490)
    2012/07/11-15:20:59.579 INFO  [CHANNEL 192.168.3.22:~3343~] graceful close, status (of previous failure, may not indicate problem) ERROR_SUCCESS(0)
    2012/07/11-15:20:59.579 WARN  cxl::ConnectWorker::operator (): GracefulClose(1226)' because of 'channel to remote endpoint 192.168.3.22:~3343~ is closed'
    2012/07/11-15:20:59.829 INFO  [GEM] Node 1: EnterRepairStage1: Gem agent for node 1
    2012/07/11-15:21:00.141 INFO  [GEM] Node 1: EnterRepairStage2: Gem agent for node 1
    2012/07/11-15:21:00.499 WARN  [RCM] Moving orphaned group Available Storage from downed node SQLTESTSQLB to node SQLTESTSQLA.
    2012/07/11-15:21:00.499 WARN  [RES] IP Address <Cluster IP Address>: WorkerThread: NetInterface ef150d1a-f4a1-4f4f-a5c7-6e7cb2bfacab changed to state 3.
    2012/07/11-15:21:00.499 WARN  [RCM] Moving orphaned group MSSTEST from downed node SQLTESTSQLB to node SQLTESTSQLA.
    2012/07/11-15:21:00.546 WARN  [RES] IP Address <SQL IP Address 1 (DEVSQL)>: Failed to delete IP interface 2003B882, status 87.
    2012/07/11-15:21:00.562 WARN  [RES] Physical Disk <Cluster Disk 2>: PR reserve failed, status 170
    2012/07/11-15:21:00.577 WARN  [RES] Physical Disk <Cluster Disk 1>: PR reserve failed, status 170
    2012/07/11-15:21:00.593 WARN  [RES] Physical Disk <Cluster Disk 3>: PR reserve failed, status 170
    2012/07/11-15:21:02.215 WARN  [NETFTAPI] Failed to query parameters for 192.168.3.32 (status 80070490)
    2012/07/11-15:21:02.215 WARN  [NETFTAPI] Failed to query parameters for 192.168.3.32 (status 80070490)
    2012/07/11-15:21:05.864 DBG   [NETFTAPI] received NsiParameterNotification  for fe80::5cd:8cc2:186:f5cb (IpDadStatePreferred )
    2012/07/11-15:21:06.565 ERR   [RES] Physical Disk <Cluster Disk 2>: Failed to preempt reservation, status 170
    2012/07/11-15:21:06.581 ERR   [RES] Physical Disk <Cluster Disk 2>: OnlineThread: Unable to arbitrate for the disk. Error: 170.
    2012/07/11-15:21:06.581 ERR   [RES] Physical Disk <Cluster Disk 2>: OnlineThread: Error 170 bringing resource online.
    2012/07/11-15:21:06.581 ERR   [RHS] Online for resource Cluster Disk 2 failed.
    2012/07/11-15:21:06.581 WARN  [RCM] HandleMonitorReply: ONLINERESOURCE for 'Cluster Disk 2', gen(0) result 5018.
    2012/07/11-15:21:06.581 ERR   [RCM] rcm::RcmResource::HandleFailure: (Cluster Disk 2)
    2012/07/11-15:21:06.581 WARN  [RES] Physical Disk <Cluster Disk 2>: Terminate: Failed to open device \Device\Harddisk5\Partition1, Error 2
    2012/07/11-15:21:06.581 ERR   [RES] Physical Disk <Cluster Disk 1>: Failed to preempt reservation, status 170
    2012/07/11-15:21:06.581 ERR   [RES] Physical Disk <Cluster Disk 1>: OnlineThread: Unable to arbitrate for the disk. Error: 170.
    2012/07/11-15:21:06.581 ERR   [RES] Physical Disk <Cluster Disk 1>: OnlineThread: Error 170 bringing resource online.
    Full cluster log here:
    https://skydrive.live.com/redir?resid=A694FDEBF02727CD!133&authkey=!ADQMxHShdeDvXVc

  • 169.254.1.97 (MS failover Cluster Adapter) - Exchange 2010 sp3

    My exchange DAG with 2 nodes. noticing this weird IP address 169.254.1.97 (MS failover Cluster Adapter) on both nodes when I run IPCONFIG/all. 
    Time to time I see this address in the msg headers too.  I can ping this address from either nodes but cannot ping from the lan.  I am not sure where is this coming from ….. Any !deaz.
    thanks

    My exchange DAG with 2 nodes. noticing this weird IP address 169.254.1.97 (MS failover Cluster Adapter) on both nodes when I run IPCONFIG/all. 
    Time to time I see this address in the msg headers too.  I can ping this address from either nodes but cannot ping from the lan.  I am not sure where is this coming from ….. Any !deaz.
    thanks
    Hi,
    Download nvspbind from MSDN Gallery and change the bindings order.
    "The Microsoft Failover Cluster Virtual Adapter" should be moved down in the list.
    See information about this in
    http://technet.microsoft.com/en-us/magazine/gg314976.aspx
    Martina Miskovic

  • Inexplainable 2008 Failover Cluster Issues

    Hi,
    We have a 2008 Failover Node & Disk Majority SQL 2005 cluster.
    There are 2 nodes in the cluster with 2008 Ent 64-bit SP2 installed.
    At around 00:20 each morning we see various FailoverClustering errors in the event logs on both servers.
    EventID: 1135, 1069, 1177
    Before the FailoverClustering events are seen, 2 informational events appear regarding the 'Microsoft Failover Clustering Virtual Adapater'
    EventID: 4201 'The system detected that network adapter Local Area Connection* 9 was connected to the network, and has initiated normal operation.'
    This is causing the resources to failover to the secondary node.
    I have run the Cluster Validation Wizard and everything passes. I have disabled the Windows Firewall service on both nodes.
    We are presenting the storage via NetApp and the nodes have 3 nics installed
    NIC1 - Server Vlan - Speed/Duplex Set to 1000Mb Full
    NIC2 - Storage Vlan - Speed/Duplex Set to 1000Mb Full
    NIC3 - Heartbeat - Speed/Duplex Set to 100Mb Full
    Please can anyone help me troubleshoot these issues ?
    Thanks
    Scott

    Hi Scott,
    Event ID 1135 — Cluster Service Startup
    http://technet.microsoft.com/en-us/library/dd353973(WS.10).aspx
    Event ID 1069 — Clustered Service or Application Availability
    http://technet.microsoft.com/en-us/library/dd353893(WS.10).aspx
    Event ID 1177 — Quorum and Connectivity Needed for Quorum
    http://technet.microsoft.com/en-us/library/dd353872(WS.10).aspx
    Event ID 4201 — TCP/IP Network Interface Connectivity
    http://technet.microsoft.com/en-us/library/dd392958(WS.10).aspx
    Hope it helps.
    Tim Quan - MSFT

  • Gentoo Linux and Microsoft Failover Clusters / Hyper-V

    Hello,
    Hoping there are a few people on the boards familiar with running Gentoo Linux guests under Microsoft FailOver Cluster / Hyper-V hosts.
    I have four Gentoo Linux guest VMs (running kernel 3.12.21-r1) running under the Microsoft Failover Cluster system with Hyper-V as the host. All of the Hyper-V drivers are built into the kernel (including the utilities and balloon drivers) and generally they
    run without issue.
    For several months now, however, I have been having strange issues with them. Essentially they stop responding to network requests after random intervals. However, these intervals aren't a few minutes or hours from each other; more like days or even weeks before
    one of them will stop responding on the network side.
    The funny thing is that the VMs themselves on the console side still responds. However, if I issue a reboot command on the externally non-responsive VM, the system will eventually get to a stage where all of the services are stopped and then hangs right after
    the "mounting remaining system ro" line (or something like that).
    The Failover Cluster Manager then reports that the system is "Stopping" but the system never reboots.
    I have to completely restart the HOST system so that either (A) the VM in question transfers to another host and starts responding again or (B) when the HOST comes back up I can work with the VM again.
    This *ONLY* happens on the Gentoo Linux guest VMs and not my Windows VMs.
    Wondering if anyone has hints on this.
    Thank you for your time.
    Regards, Christopher K.

    Hi ckoeber,
    Hyper-V has support most of Linux distribution but not all because it’s have so many distribution, until now the Gentoo Linux not in the support list, you can refer the following
    KB to know more about the detail:
    Linux Virtual Machines on Hyper-V
    http://technet.microsoft.com/en-US/library/dn531030
    Hope this helps.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Hyper-V Failover Cluster Live migration over Virtual Adapter

    Hello,
    Currently we have a test environment 3 HyperHost wich have 2 Nic teams.  LAN team and team Live/Mngt.
    In Hyper-V we created a Virtual Switch (Wich is Nic team Live/Mngt)
    We want to seperate the Mngt and live with Vlans. To do this we created 2 virtual adapters. Mngt and Live, assigned ip adresses and 2 vlans(Mngt 10, Live 20)
    Now here is our problem: In Failover cluster you cannot select the Virtual Adapter(live). Only the Virtual Switch wich both are on. Meaning live migration simple uses the vSwitch instead of the Virtual adapter.
    Either its not possible to seperate Live migration with a Vlan this way or maybe there are Powershell commands to add Live migration to a Virtual adapter?
    Greetings Selmer

    It can be done in PowerShell but it's not intuitive.
    In Failover Cluster Manager, right-click Networks and you'll find this:
    Click Live Migration Settings and you'll find this:
    Checked networks are allowed to carry traffic. Networks higher in the list are preferred.
    Eric Siron
    Altaro Hyper-V Blog
    I am an independent blog contributor, not an Altaro employee. I am solely responsible for the content of my posts.

  • Changing Hyper-V host and cluster virtual IP addresses to new subnet/VLAN

    I have a 2 node Hyper-V 2012 R2 failover cluster, managed by System Center Virtual Machine Manager 2012 R2, and I would like to change the IP addresses of the hosts and the cluster, in order to move them to a new subnet and VLAN. The existing and new subnets
    are able to route to each other so all hosts will still be able to communicate throughout the parts of the process where they may be on separate subnets. There is also a dedicated cluster heartbeat network on its own subnet and VLAN that I am not altering
    in any way.
    The 2 hosts are configured with 4 nics in a team, with dedicated virtual interfaces for each of the following:
    -Live Migration
    -Cluster Heartbeating
    -Host management/general traffic (the cluster virtual IP address is also on the same subnet as these interfaces).
    It is the host management/general traffic addresses that I want to change. The interfaces were created and configured with the Add-VMNetworkAdapter, New-NetIPAddres and Set-VMNetworkAdapterVlan commands.
    Please advise if the following process is correct:
    1) Evacuate all the VMs from the first host to be changed and put it in maintenance mode.
    2) Use Set-VMNetworkAdapter to change the name of the interface (the current name refers to the VLAN it's on)
    3) Use Set-NetIPAddress to change the IP address and gateway of the interface as appropriate
    4) Use Set-VMNetworkAdapterVlan to set the VLAN ID
    5) Take the host out of maintenance mode and move all VMs off the other host
    6) Repeat above steps on the other host
    I know that I will then need to change the cluster virtual IP address, but I have no idea how to do this or where to look for that setting. Please advise!
    Cheers.

    Hi new_guise,
    For changing cluster node's IP address please refer to the link below :
    https://support.microsoft.com/kb/230356?wa=wsignin1.0
    For changing VIP please refer to this article :
    http://blogs.technet.com/b/chrad/archive/2011/09/16/changing-hyper-v-cluster-virtual-ip-address-vip-after-layer-3-changes.aspx
    Best Regards,
    Elton Ji
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • Windows server 2012 failover cluster error: Cluster resource 'Virtual Machine Configuration ... of type 'Virtual machine configuration in clustered role ... failed.

    I have two windows 2012 host server that are clustered using windows failover cluster feature. Each server is hosting four VMs. When migrating from Host2 to Host1, the migration failed with the following error:
    Cluster resource 'Virtual Machine Configuration SCPCSQLSRV01' of type 'Virtual Machine Configuration' in clustered role 'SCPCSQLSRV01' failed. The error code was '0x569' ('Logon failure: the user has not been granted the requested logon type at this computer.').
    When this happens, the VM that I was migrating can no longer be started even on the original host. The only remedy is to restart the host server.
    Any suggestion on resolving this problem?
    Thanks
    Ikad

    Thanks. The article referred to above gives the solution to my issue. There is a group policy that is applied to the OU where the host servers were placed. Doing gpupdate /force temporarily removes the problem. Unfortunately the NT Virtual Machine\Virtual
    Machines account is a special account that cannot be added like other accounts and granted the log on as a service right. The thread
    http://social.technet.microsoft.com/Forums/en-US/winserverhyperv/thread/d56f2eae-726e-409a-8813-670a406593e8 contains how it can be added which is by creating a group and running the command
    Net localgroup VMTest “NT Virtual Machine\Virtual Machines” /add
    to add it to a local group VMTest. VMTest is then assigned the right to log on as a service.
    Ikad

  • Virtual Domain Controllers in 2012 Failover Cluster. Time Skew

    Hi All,
    Not sure if this is the correct space for this topic, however i'll give it a go anyway.
    We have a 2 Hosts (HP DL385) Windows Server 2012 Failover Cluster.
    Storage is provided by a 12 Bay NAS with iSCSI connections (This is catering for CSV's and Quorum)
    We are running 2 Virtual domain controllers (2008R2)
    The issue we experience is that if the cluster goes down, and when it comes back online the time on the domain controllers (one or the other or both) skews by any where up to 3 days which causes havoc for our office until we can resync clocks with the PDCe.
    Time Synchronisation Integration Service is disabled on both Domain Contollers
    A few days back we need to reboot the storage on the cluster, and the tasks performed were as follows:
    -Power off all virtual machines (Graceful Shutdown)
    -Put all CSV's into maintenance mode
    -Offline Disk Witness to Quorum
    -Rebooted Storage (Waited until it came back online)
    -Online Quorum Storage (Successful)
    -Bring CSV's out of maintenance mode (Successful & Browsable)
    -Power on all Virtual Machines (Successful)
    This is where the time Skewed and caused headaches. The time for some reason went to 2 days 11hrs in the past on 1 domain controller.
    With this DNS lookups failed to work, Cluster services failed, Cluster Aware Updating Failed, RDP to VM's (and Virtual Hosts) by DNS Name failed (Date time error) 
    There doesn't seem to be anything in the EventLog except for date/time stamp on events being 2 days in the past.
    Now this is why i'm not sure if the issue is cause by fail over clustering, or is an issue with the domain controllers.
    Any advice regarding this or if anyone has seen this behaviour before any info would be great
    Thanks
    Rob 

    Hi Rob,
    Does both this two DCs on your cluster VM and there have not others DCs? Microsoft recommends that files for virtualized domain controllers be placed on non-CSV
    disks, Non-CSV disks can be brought online without authentication. Because non-CSV disks can be brought online more easily.
    For virtual machines that are configured as domain controllers, it is recommended that you disable time synchronization between the host system and guest operating
    system acting as a domain controller. This enables your guest domain controller to synchronize time from the domain hierarchy, please confirm your PDC time is always correct.
    The related KB:
    Running Domain Controllers in Hyper-V
    https://technet.microsoft.com/en-us/library/d2cae85b-41ac-497f-8cd1-5fbaa6740ffe(v=ws.10)#deployment_considerations_for_virtualized_domain_controllers
    Things to consider when you host Active Directory domain controllers in virtual hosting environments
    http://support.microsoft.com/kb/888794?wa=wsignin1.0
    I’m glad to be of help to you!
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

Maybe you are looking for