Minimum value of UNIX/Linux Heartbeat Monitor in scom 2012

Hi,
In my environment, we have SCOM 2012 server, when I change values of UNIX/Linux
Heartbeat Monitor: Interval , Missed
Heartbeats and Missed Heartbeats from 300 , 630 ,2 to 120, 150, 1 in event viewer shows Error
11112:
The Microsoft Operations Manager Consolidate Module failed to initialize because the specified compare count is less than the minimum
Compare count value : 1
Minimum value allowed : 2
One or more workflows were affected by this.
What is the best minimum value?
Thanks

You've ended up in the wrong forum. mostly service manager here, Ops manager is
over there https://social.technet.microsoft.com/Forums/en-US/home?category=systemcenteroperationsmanager. 
That being said, the error you reference is somewhat abstracted from the values you adjusted. the error you posted is the system comparison operator complaining that it only has one thing to compare, typically you need two things to do a comparison.
Here is a person running into a similar problem with the lync MP, where it was trying to compare the site assignment of two systems, but the environment only has one system.
http://thoughtsonopsmgr.blogspot.com/2014/09/lync-server-2010-mp-bug-alert.html. is it possible this is an outgrowth of something similar in your unix environment? Do you have any more details about the specific health XML that's failing?

Similar Messages

  • Where is unix/linux agent located on scom 2012 r2 server

    hey there,
    my boss tried to install scom unix agent manually, and asked me where the unix agent located on scom 2012 r2 server.
    Is it "GetOSVersion.sh" the one he looks for? If it is not, then wherw it is located
    I'm a Windows guy and have no idea what that .sh file is. Please help~~

    The "GetOSVersion.sh" is a script that is first executed when you try to push an agent out to
    a unix/linux server. It then tells SCOM what version of the agent it needs to download and install.
    As for the location:
    Management Server: \System Center Operations Manager\Server\AgentManagement\UnixAgents\DownloadedKits
    Gateway Server: \System Center Operations Manager\Gateway\AgentManagement\UnixAgents\DownloadedKits
    I suggest to push the agent out vs manual install as you then don't need to worry about manually signing certificates/installing agent. Its saves considerable amount of
    time and your then managing your agents from a central location. 
    Oh and as Steve mentioned make sure you download the Unix Management pack bundle (MPB) and not from the online catalog. This is due to the MPB is what actually contains the agents where as the catalog is just the management packs.
    Cheers,
    Martin
    Blog:
    http://sustaslog.wordpress.com 
    LinkedIn:
    Note: Posts are provided “AS IS” without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and/or fitness for a particular purpose.

  • Unix/Linux Process Monitoring

    When I attempt to run the add monitoring wizard in Operations Manager 2012 R2 against the unix/linux process monitor I receive the following error :-
    Date: 12/02/2015 11:55:23
    Application: Operations Manager
    Application Version: 7.1.10226.0
    Severity: Error
    Message:
    Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.UISDKException: The page [Microsoft.SystemCenter.CrossPlatform.UI.OM.Integration.Authoring.ProcessTemplate.ProcessDetailsPage] in the assembly [Microsoft.SystemCenter.CrossPlatform.UI.OM.Integration.Authoring.ProcessTemplate,
    Version=7.0.6000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35] could not be loaded. Please make sure that the account you are running under has sufficient privileges to load the given assembly, or the Management Pack that defines this page is installed
    or the assembly containing the page is in the path of the executable or that the page derives from known Operations Manager page type. ---> System.Reflection.ReflectionTypeLoadException: Unable to load one or more of the requested types. Retrieve the LoaderExceptions
    property for more information.
       at System.Reflection.RuntimeAssembly._nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, RuntimeAssembly locationHint, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, Boolean forIntrospection,
    Boolean suppressSecurityChecks)
       at System.Reflection.RuntimeAssembly.InternalLoadAssemblyName(AssemblyName assemblyRef, Evidence assemblySecurity, RuntimeAssembly reqAssembly, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, Boolean forIntrospection,
    Boolean suppressSecurityChecks)
       at System.Reflection.RuntimeAssembly.InternalLoad(String assemblyString, Evidence assemblySecurity, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean forIntrospection)
       at System.Reflection.RuntimeAssembly.InternalLoad(String assemblyString, Evidence assemblySecurity, StackCrawlMark& stackMark, Boolean forIntrospection)
       at System.Reflection.Assembly.Load(String assemblyString)
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.UIPageSet.CreatePage(String assemblyName, String typeName)
       --- End of inner exception stack trace ---
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.UIPageSet.CreatePage(String assemblyName, String typeName)
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.UIPageSet.GetPages()
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.MomTemplatePagesManager.GetPages()
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.PageManagerBase.AttachToFramework(IPageFramework pageFramework, Boolean readOnly)
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Pages.TemplateListPage.AddPagesForSelectedItem()
    System.Reflection.ReflectionTypeLoadException: Unable to load one or more of the requested types. Retrieve the LoaderExceptions property for more information.
       at System.Reflection.RuntimeAssembly._nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, RuntimeAssembly locationHint, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, Boolean forIntrospection,
    Boolean suppressSecurityChecks)
       at System.Reflection.RuntimeAssembly.InternalLoadAssemblyName(AssemblyName assemblyRef, Evidence assemblySecurity, RuntimeAssembly reqAssembly, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, Boolean forIntrospection,
    Boolean suppressSecurityChecks)
       at System.Reflection.RuntimeAssembly.InternalLoad(String assemblyString, Evidence assemblySecurity, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean forIntrospection)
       at System.Reflection.RuntimeAssembly.InternalLoad(String assemblyString, Evidence assemblySecurity, StackCrawlMark& stackMark, Boolean forIntrospection)
       at System.Reflection.Assembly.Load(String assemblyString)
       at Microsoft.EnterpriseManagement.Internal.UI.Authoring.Extensibility.UIPageSet.CreatePage(String assemblyName, String typeName)
    I receive this in my test lab and in a live environment. Both environments are running Operations Manager 2012 R2 and I have imported the latest management packs which are 7.5.1042.0.
    I am full administrator at the server and operations manager level. So what is it I am missing?
    Thanks.

    Agree with Steve, Upgrade to last UR, This issue is related to Management Pack so that Check correct version of Management Pack which is compatible with SCOM 2012R2
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"Mai Ali | My blog:
    Technical | Twitter:
    Mai Ali

  • SCOM 2007R2 unix/linux service monitor setup - cannot discover service under /etc/init.d

    SCOM 2007R2 unix/linux service monitor setup - cannot discover service under /etc/init.d

    Can you give a few more details on what you have tried, and what didn't work for you? Were you stepping through the wizard to monitor a Linux/UNIX service and something went wrong? Or did you successfully create the service monitor in the wizard, but it
    didn't trigger if the monitored process terminated?
    Michael Kelley, Lead Program Manager, Open Source Technology Center

  • Bulk URL Monitoring is SCOM 2012 SP1

    Hey Team,
    i need to setup 100 + url monitors in scom 2012 sp1, i came across a term named BULK URL Monitor which suits my requirement. The issue is i am failing to get it to work when i click Bulkmonitor.exe i am gettign the below error and not sure how to resolve
    it.
    System.IO.FileNotFoundException: Could not load file or assembly 'Microsoft.EnterpriseManagement.Core, Version=7.0.5000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified.
    File name: 'Microsoft.EnterpriseManagement.Core, Version=7.0.5000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35'
       at Microsoft.EnterpriseManagement.BulkUrlManager.BulkUrlManagerForm..ctor()
       at Microsoft.EnterpriseManagement.BulkUrlManager.Program.Main()
    WRN: Assembly binding logging is turned OFF.
    To enable assembly bind failure logging, set the registry value [HKLM\Software\Microsoft\Fusion!EnableLog] (DWORD) to 1.
    Note: There is some performance penalty associated with assembly bind failure logging.
    To turn this feature off, remove the registry value [HKLM\Software\Microsoft\Fusion!EnableLog].
    Any suggestions will be highly appreciated.
    -vrkumar01
    RajKumar

    It worked.
    intially i tried to install in \System Center 2012\Operations Manager\Setup & System Center 2012\Operations Manager\Server both failed but this
    System Center 2012\Operations Manager\Console worked.
    thanks a lot
    -vrkumar01
    RajKumar

  • Windows Azure Monitoring in SCOM 2012 R2

    Hi,
    We have Azure subscription which has few cloud services and VM in running state. We want to monitor the VMs running on Azure using SCOM 2012 R2 running on our corp network behind firewall. SCOM Server connected to the internet through the corp proxy.
    We have imported the Azure Management packs in to SCOM and Added the Subscription successfully. But, the Azure resource inventory like Discovered Cloud Services, Discovered Storage, Discovered Virtual Machines are empty.
    Kindly please help to configure azure monitoring using SCOM 2012 R2.
    Thanks
    Kumaresan Lakshmanan

    Hi 
    SCOM monitoring check data in azure store, check if the events and performace data is transferring to the azure store.if data is not transfering for event id counters monitor fail to work . 
    refer below link for more information
    Implementing Windows Azure
    Diagnostics (http://go.microsoft.com/fwlink/?LinkId=186765).
    Transferring Diagnostic
    Data to Windows Azure Storage (http://go.microsoft.com/fwlink/?LinkId=191347). 
    Regards
    sridhar v

  • Dell server hardware component monitoring with scom 2012 R2.

    hello ..
    We have some dell poweredge r710 SFF 2X SIX CORE X5 SAS Servers ,I need to monitor its hardware components with scom2012 R2.I have installed os:windows server hyper-v server on this and windows server core OS management packs on scom and monitoring
    working fine  .next I want to know their is Latest Management pack available for this  dell model server and what are hardware components can be monitored with scom 2012 R 2. I want to monitor Hardware failure such as   Power failure ,cpu failure,disk
    failure and NIC failure etc
    Thanks
    Richa

    Hi,
    Please refer to the User’s Guide of the DELL MP:
    http://support.dell.com/support/edocs/software/smconect/msscom/40/en/ug/pdf/Dell_Server_Management_Pack_Suite_v4.0_UG.pdf
    Please Note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Meanwhile, considering this is related to DELL products, if you need more information or further investigation, please also contact DELL support
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • How to enable default disabled linux monitor on scom 2012 r2

    hello,
    I have scom 2012 r2 environment and i have imported 'SCOM 2012 R2 MP linux and Unix '.then installed agent on one of linux redhat6 machine.it got installed successfully but next how to get data in following highlighted portion except these am getting data
    in all the portion.

    To enable disabled rule,you can run below script by write MP name and class that you want to enable it
    $MP
    = Get-SCOMManagementPack
    -displayname "Managment pack name"
    | `
    where {$_.Sealed
    -eq $False}
    $Class
    = Get-SCOMClass
    -DisplayName "rule name"
    $Rule
    = Get-SCOMRule
    -DisplayName "*Events/sec"
    Enable-SCOMRule -Class
    $Class -Rule
    $Rule -ManagementPack
    $MP -Enforce
    For more details, you can refer below link
    http://www.systemcentercentral.com/opsmgr-2012-disabling-rules-and-monitors-in-bulk-in-powershell/
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • Performance of Network Monitoring in SCOM 2012 SP1

    Hi all!
    I´ve problems with performance of the network monitoring feature in SCOM 2012 SP1.
    According to the
    guide the following should be adeqate:
    •1000 network devices (approximately 12,500 monitored ports) managed by a resource pool that has three or more management servers
    •500 network devices (approximately 6,250 monitored ports) managed by a resource pool that has two or more gateway servers
    We have 800 network devices with a total of 24000 ports,
    BUT only 1500 of them are monitored. This is basically what happens automatically after discovery, since only ports between monitored devices are monitored by default.
    For this setup I first used only one management server dedicated to the Network Pool,
    based on my assumption that if two servers could monitor 6250 ports, one server would be more than enough for 1500. I found this configuration working very poorly so I added another server. I now have two servers
    dedicated for the Network Resource Pool. (They are NOT members of the “All management servers resource pool”)
    Still, I get constant alerts regarding Health Services Private Bytes on these servers. They vary between 1-2Gbytes. Furthermore, if one of the servers goes offline, the network devices that was monitored by that server becomes grey for
    several hours. Even if the server only is rebooted it takes forever to get everything online and green again.
    I don´t really know what I should do now. I had a plan to replace our current network monitoring system (SNMPc) which easily handles this load on only one server. They are of course completely different beasts, but still. SCOM seems to
    require a massive back-end to produce equivalent real life results.
    Any suggestions or reflections from the field are highly appreciated!
    Regards
    Peter

    Hi,
    Try to overide the monitor Health Services Private Bytes by the following steps.
    ◾Go Authoring space – Management Pack Objects – Monitors
    ◾Go to change scope – select clear all – look for Health Service – tick it and press OK.
    ◾Expand Health Service – expand Entity Health – expand Performance – expand Health Service Performance
    ◾Select the Health Health Service Private Bytes Threshold.
    ◾Right click the mouse and choose to overide the monitor for a group
    ◾Select the group called Management Server Computer Group and press OK
    ◾Select the Agent Performance Monitor Type – Threshold and change the value 104857600 to ex. 2610612736.
    ◾Select to store the overide in a management pack you have created and press OK
    Juke Chou
    TechNet Community Support

  • General hardware monitoring on SCOM 2012 R2

    Hello everybody. Sorry for maybe common question, i'm absolutely newbie in SCOM. I'm standing at task of monitoring basic servers counters - Memory utilization, disk free space & CPU utilization. After reading some articles about SCOM architecture I
    get a little frustrated - cannot get full understanding about monitoring mechanisms. What I want from my monitors:
    - Monitor 2,3...N groups of servers with _different_ disk free space thresholds and sending alerts (email) to specific people.
    I've already have imported management pack for Windows OS, configure channels & subscribers.
    I get a lot of question trying to configure such monitoring, maybe you can help me (or send me to manuals)
    1. I can use monitor's for specific OS (i.e. logical disk free space), then I need to override it(why? I can't use it?) and select servers.
    2. How can I map a group of servers to monitor?
    3. Do I need rules?
    4. New monitor sets in installed agents automatically?
    Cannot understand steps, in which I should resolve my task..

    1. Windows OS management pack has default monitor for disk free space and CPU utilization. If you 2,3,...N groups of servers with different disk free space thresholds, you should create Groups which contains the required servers and using override with target
    of the gorups.
    For how to create an override, pls. refer
    http://jimmoldenhauer.blogspot.hk/2012/11/scom-2012-creating-overides.html
    2. The target of the monitor is set to the groups of server
    3. It depend on situation
    Rules do not affect the health state of the target object. They are used for one of three functions
    a) Alerting Rules
    Alerting rules create an alert when a particular event is detected. This can be any of the different kinds of events shown in Data Sources. Alerting rules do not affect health state.
    b) Collection Rules
    Collection rules collect events or performance data to the Operations Manager database and data warehouse. They do not create alerts or set health state.
    Collection rules can use each of the data sources shown in Data Sources. The data will be converted to either an event or to performance data depending on the particular kind of collection rule you are creating. For some wizards, you will need to provide
    the specific information from the data source that will be used for different properties of the data being collected.
    c) Command Rules
    Command rules will run a script or command on a schedule. They do not create alerts or collect any data.
    4) All agents will automatic download updated its monitor and rule which applicable to the server.
    Roger

  • Services monitored by SCOM 2012

    Hi All,
    I am using SCOM 2012 SP1 in our environment. I am a bit puzzled about what all services of a windows server are monitored by default in SCOM. I am asking this because recently we have WinRM service stopped on a windows server but no alert get generated in
    SCOM. Does I need to manually set up monitoring for this service?
    Regards,
    Daya

    Hi,
    The System Center Management Pack for Windows Server Operating System provides the fundamental monitoring basics for computers.
    From what I can see, the WinRM service is not monitorred by default.
    And I would like to suggest you also download the MP guide for Operating System management pack to get more details:
    http://www.microsoft.com/en-hk/download/details.aspx?id=9296
    Regards,
    Yan Li
    Regards, Yan Li

  • Exchange 2010 and 2013 Monitoring with SCOM 2012

    HI all,
    I have exchange 2013 and 2010 in my environment , Iwant monitor both in SCOM 2012,
    Can you all please tell can i implement 2013 monitorinng first later can i go to 2010 Monitoring, Please advise in that supported or do i need to go with exchange 2010 monitoring first

    There are no dependencies on the 2010 MP so you should be good to go, see the following:

  • Need to separate drive alerts with Logical Disk Free Space monitoring in SCOM 2012

    I have an interesting need here to separate our SCOM alerts for Logical Disk Free space so that one alert is for OSSystem drives ONLY (C:/D:) and the other monitor alerts on all APP drives only (E:, etc). So far we have had great success using Kevin Holman's
    blog post.
    http://blogs.technet.com/b/kevinholman/archive/2009/11/24/writing-monitors-to-target-logical-or-physical-disks.aspx
    We have overrides set so that the monitors report ONLY the percentage of free space left and ignores any MB threshold. So far so good, the alert comes in that host A reports low disk space on D: at 2.345...% free or host B reports low disk space on F: at
    4.567...% free space etc. Now that we have our monitors working within the Windows Server classes Logical Disk, we need to set these monitors so that one is just for C or D drives with the alert named system Logical Disk Free Space OS Disk Warn and the other
    monitor just reports on E - Z drives (excluding C or D) with the alert named Logical Disk Free Space APP Disk Warn.
    We are very new to SCOM so I made the rookie mistake of creating a dynamic group for all Windows Server 2003 Logical Disk class that only includes Device Name = C or D. But found out too late you cant point a monitor to a group, it has to target a class.
    And using the current monitors we set up with the above blog uses the correct logical disk class, but it doesnt care what instance (device Id = value), it will report low disk space on ANY logical drive. How in the world can we separate and exclude these monitors
    so that one alerts only on OS disks (C and D) and the other only alerts on app disks (E through Z)?

    Hi Kevsharp,
    Quite confusing after reading your question.
    So based on your requirement, What i understand is you need separate alerts for all the drives of the disk is running at low or out of space right ?
    For the above just create a simple performance counter monitor and use the same counters as kevin has used in his blog.
    Now Target: Use Windows server operating system (This will target all the Windows operating system agents in your SCOM. If the specified discovery MP's are installed).
    Set a threshold Below 10% is critical or what ever. You will get the alerts in your console.
    Gautam.75801

  • Some of the SQL Server 2012 are not getting monitored in SCOM 2012 SP1.( basics monitoring is happening, expect SQL role)

    Found that all the SQL servers are getting monitored, expect few servers which are having SQL server 2012 role.
    proxy is enabled for these servers, when I checked discovered inventory for SQL 2012 database unable to find these servers in that list.
    and other servers having SQL Server 2012 monitoring properly issue is with only few servers.

    Hi,
    thanks for the all the input, we are using service account as windows account instead of action account !!
    will that also affect discovery of SQL role?
    and also found that there are many alerts in SCOM console, with alert description :
    SQL Server cannot authenticate using Kerberos because the Service Principal Name
    (SPN) is missing, misplaced, or duplicated.
    please let me know how we can resolve this issue, will it affect SQL discovery as well ?

  • Weblogic Monitoring with SCOM 2012

    Hello,
    I need to monitor WebLogic 10.3 installed on Windows Server 2008 SP2 so I added these MP :
    Microsoft.JEE.WebLogic.Library.mp
    Microsoft.JEE.WebLogic.10gR3.mp
    Microsoft.JEE.Library.mpb
    Microsoft.JEE.Templates.Library.mpb
    And I created a specific basic account (with administrator application rights) that I linked to the JEE Monitoring Account Profile.
    I checked in the Event Viewer and I got : Event 1109 - All credential references resolved successfully.
    But when I can't see anything in the Weblogic Application Servers specific views. And in the Heath Explorer of my server I have this :
    For information, I don't get any error in the event viewer about this.
    Can someone help ? Thanks.

    1) What is the exact version of WebLogic that you're installing? 
    WebLogic Server Version: 10.3.0.0
    2) In the WebLogic installation root, there is a registry.xml file. What is the version
    listed for the Xpath: /bea-product-information/host/product/release?
    <release level="10.3" ServicePackLevel="0" PatchLevel="0" Status="installed" BeaProgramGroup="Oracle WebLogic" StartMenu="C:\Documents and Settings\All Users\Start Menu\Programs"
    InstallTime="Oct 17, 2008 5:10:52 PM" InstallDir="D:\bea10.3" JavaHome="D:\bea10.3\jdk160_05" JavaVersion="1.6.0_05" JavaVendor="Sun">
    3) In the domain, is there a domain-registry.xml?  If so, what are its contents?
    In the domain, domain-registry.xml is missing.
    4) Are there managed servers on that WebLogic domain & the same machine?  If
    so, have they been discovered?
    Yes there is a managed server on that Weblogic domain on the same machine, no it hasn't been
    discovered.
    5)
    What do you mean by "There is no monitoring of Weblogic admin servers". Here the monitoring needs of our application admin :
    connections per application
    Weblogic server status (running / problem /other)
    JVM Memory
    6) You mentioned that you enabled unit monitors, can you clarify specifically which unit monitors you enabled? 
    7) Have you tried the PowerShell script yet & did that work?
    Not yet. I will try.

Maybe you are looking for

  • Cover Flow... Style Over Substance

    I don't know about you but I think that someone, somewhere deep in halls of Cupertino have got themselves into a right royal frenzy over Cover Flow. We all remember that Cover Flow first appeared as a shareware plug-in for iTunes. Sure, it looked goo

  • Is there a way to work with the touch screen on photoshop?

    i have a laptop and i want to use the touch screen to draw in photoshop. can anybody help me? thanks!

  • I deleted all my photos on iphoto and want to restore them back

    I deleted all my photos on iphoto library and then i deleted it in trash too and now I want to retrieve all those photos back! Is it possible?

  • Updated and now tool windows are not showing up.

    I just updated my Muse and the pop open tool windows are not showing up. For example when I click on some text and then click on the list of typfaces the typeface window shutters and won't show up. This window keeps blinking from gray to black. I hav

  • PC fonts on a Mac

    My wife is getting a new Mac having been using a PC and built up a substantial font collection for the PC. What are the issues for using/converting PC fonts to Mac and vise versa? What do we need to convert them? We will be running Parallels so do we